P-002 EDI: Rapid Airfield Damage Recovery Storage Facilities, Aviano Air Base, Italy
Solicitation number
N6247022R3000
Issued by

About this file

This document provides details on a federal solicitation for construction services. The solicitation number is N6247022R3000 and is being issued by the Department of the Navy Naval Facilities Engineering Command for Rapid Airfield Damage Recovery Storage Facilities at Aviano Air Base in Italy. The solicitation seeks offers for the construction of storage facilities to support rapid repair of airfield damage. Offerors should respond in accordance with the requirements and instructions set forth in the solicitation. The anticipated award date was not specified.

View the file

Other files

File Type Posted
Amendment 0009.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007.pdf PDF
Attachment S - Revised Drawing CU101A.pdf PDF
Attachment O - Site Visit Sign In.pdf PDF
Attachment T - Revised Drawing CU101B.pdf PDF
Attachment R - Revised Drawing CS102B.pdf PDF
Attachment U - Revised Specification 01 50 00.pdf PDF
Amendment 0006.pdf PDF
Attachment P - Site 2 Access Road Aerial.pdf PDF
Attachment Q - Revised Drawing CD101A.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0003.pdf PDF
Attachment N - Gas Line Trench Detail.pdf PDF
Amendment 0002.pdf PDF
Attachment M - Installation Access Request Form.pdf PDF
Amendment 0001.pdf PDF
Attachment L - Installation Access Request Checklist.pdf PDF
Attachment E - Price Proposal Form.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
Attachment K - Italian Safety Plan_Combined.pdf PDF
Attachment H 1659896dwgVOL1_3of3.pdf PDF
Attachment H 1659896dwgVOL1_1of3.pdf PDF
Attachment H 1659896dwgVOL1_2of3.pdf PDF
Attachment C - Construction Experience Project Data Sheet.pdf PDF
Attachment G - Specifications.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment H 1659896dwgVOL2_1of4.pdf PDF
Attachment A - Pre-Proposal Inquiry Form.xls XLS spreadsheet
Attachment H 1659896dwgVOL2_2of4.pdf PDF
Attachment I - HAZMAT Report Summary.pdf PDF
Attachment J - Host Nation Code Compliance Certification.pdf PDF
N62470-22-R-3000.pdf PDF
Attachment H 1659896dwgVOL2_4of4.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

O V

E R

A L

L

S

I T

E

P

L A

N

L-101B

1:500

SEAL

A/E INFO

2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

D E

P A

R T

M E

N T

F

H E

A V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M S

C

M

M A

N D

N O

R F

O L K

V

A

DES DRW CHK

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

A

B

C

D

A

B

C

D

NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018

1659896

A T

L A

N T

I

D

S

I G

N

A

N

S T

R U

C T

I O

N

N6247022R3000

CP GC AA

A1

A1

1:500

OVERALL SITE PLAN

14121663

L-101B 1:300

EXISTING CONDITIONS AND DEMOLITIONS SITE PLAN - NORTH AREA

SEAL

A/E INFO

2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

D E

P A

R T

M E

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

N O

R F

O L K

V

A

DES DRW CHK

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

A

B

C

D

A

B

C

D

NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018

1659896

A T

L A

N T

S

I G

N

A

N

S T

R U

C T

I O

N

N6247022R3000

CP GC AA

0 5 10 15 20 30

1:300

E X

I S

T I N

G

C

O N

D I T

I O

M

O L

I T

I O

T

E

P

L A

N

N

O R

R E

A

LD102B

1:300

14121664

L-101B 1:300

EXISTING CONDITIONS AND DEMOLITIONS SITE PLAN - SOUTH AREA

SEAL

A/E INFO

2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

D E

P A

R T

M E

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

N O

R F

O L K

V

A

DES DRW CHK

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

A

B

C

D

A

B

C

D

NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018

1659896

A T

L A

N T

S

I G

N

A

N

S T

R U

C T

I O

N

N6247022R3000

CP GC AA

E X

I S

T I N

G

C

O N

D I T

I O

M

O L

I T

I O

T

E

P

L A

N

S

O U

E

A

LD103B

1:300

0 5 10 15 20 30

1:300

14121665

S I G

N

S

I T

E

A

P

L A

N T

I N

G

P

L A

N

N

O R

E

A

LS104B

1:300

L-101B 1:300

DESIGN SITE AND PLANTING PLAN - NORTH AREA

SEAL

A/E INFO

2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

D E

P A

R T

M E

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

N O

R F

O L K

V

A

DES DRW CHK

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

A

B

C

D

A

B

C

D

NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018

1659896

A T

L A

N T

S

I G

N

A

N

S T

R U

C T

I O

N

N6247022R3000

CP GC AA

12000

73400

73500

29150

43800

20400

14121666

S I G

N

S

I T

E

A

P

A

N T

I N

G

P

L A

N

S

O U

E

A

LS105B

1:300

SEAL

A/E INFO

2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

D E

P A

R T

M E

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

N O

R F

O L K

V

A

DES DRW CHK

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

A

B

C

D

A

B

C

D

NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018

1659896

A T

L A

N T

S

I G

N

A

N

S T

R U

C T

I O

N

N6247022R3000

CP GC AA

L-101B 1:300

DESIGN SITE AND PLANTING PLAN - SOUTH AREA

61000

46650

39700

35600

39000

14121667

SEAL

A/E INFO

2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

D E

P A

R T

M E

V

Y N

A V

A L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

S

Y S

T E

M

M A

N D

N O

R F

O L K

V

A

DES DRW CHK

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

A

B

C

D

A

B

C

D

NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018

1659896

A T

L A

N T

S

I G

N

A

N

S T

R U

C T

I O

N

N6247022R3000

CP GC AA

P L

A N

T

M

A T

E R

I A

H

E D

U L

E

A

T

A I L

S

LK501B

NTS

NTS

TREE PLANTING DETAIL (TYP.)

NTS

SHRUBS PLANTING DETAIL (TYP.)

NTS

GROUND COVER PLANTING WITH CURB DETAIL

NTS

DRAINAGE DEPRESSION WITH GRASS COVER DETAIL

NTS

RETENTION POND WITH RIP RAP AND GRASS COVER DETAIL

35grams/sm

14121668

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

NO SCALE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

/1

/2

:3

:4

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

G E

N E

R A

L N

O T

E S

/2

S-001B

PD AA ES

S -0

B

G E

N E

R A

L N

O T

E S

/2

14121669 255 429

N O

T E

G E

N E

R A

LI

/2

1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE

FOLLOWING US CODES:

a. UFC 1-200-01 - DOD BUILDING CODE, OCTOBER 2019

b. UFC 3-301-01 - STRUCTURAL ENGINEERING, 2019

c. IBC2018 - INTERNATIONAL BUILDING CODE, 2018

d. ASCE7-16 - MINIMUM DESIGN LOADS FOR BUILDINGS

AND OTHER STRUCTURES, 2016

e. ACI318-14 - BUILDING CODE REQUIREMENTS FOR

REINFORCED CONCRETE, 2014

f. ANSI-AISC 341-16 - SEISMIC PROVISIONS FOR

STRUCTURAL STEEL BUILDINGS, 2016

g. ANSI-AISC 360-16 - SPECIFICATIONS FOR

STRUCTURAL STEEL BUILDINGS, 2016

2. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE

FOLLOWING ITALIAN CODES:

a. TECHNICAL NORMS FOR THE CALCULATION, EXECUTION AND TESTING OF NORMAL AND

PRESTRESSED REINFORCED CONCRETE

STRUCTURES AND STEEL STRUCTURES (LAW 1086 -

5/11/1971)

b. TECHNICAL NORMS FOR SEISMIC DESIGN (LAW 64 - 2/2/1974)

c. TECHNICAL CONSTRUCTION CRITERIA (DM 17/01/2018)

d. INSTRUCTIONS FOR THE APPLICATION OF THE

CONSTRUCTION CRITERIA (CIRC.7 - 21/02/2019)

3. DESIGN LOADS

A. SUPERIMPOSED DEAD LOADS

• 1.0 kPa

B. LIVE LOADS (ITALIAN CODE)

• ROOF - CAT. H

0.50 kPa

• GROUND FLOOR - CAT. G

12.00 kPa

C. LIVE LOADS (US CODE)

• ROOF

1.00 kPa

• GROUND FLOOR

12.00 kPa

D. SEISMIC LOADS (ITALIAN CODE)

• SITE CATEGORY

B

• SERVICEABILITY LIFE

Vn=50 years

• OCCUPANCY CLASS

II

• OCCUPANCY FACTOR

Cu=1.0

• REFERENCE LIFE

50 years

• SOIL ACCELERATION FACTOR SLV

ag/g=0.2386

• RETURN PERIOD SLV

475 years

E. SEISMIC LOADS (US CODE)

• SHORT PERIOD SPECTRAL ACCELERATION

Ss=1.25

• ONE SECOND PERIOD SPECTRAL

ACCELERATION S1=0.50

• RISK FACTOR

II

• IMPORTANCE FACTOR IE

IE=1.00

• STRUCTURAL SYSTEM: MOMENT RESISTING

FRAME SYSTEM W/STEEL ORDINARY MOMENT

FRAME

• SITE CLASS

C

• SEISMIC DESIGN CATEGORY:

D

• RESPONSE MODIFICATION AND DEFLECTION

AMPLIFICATION FACTORS: R=3.5, Cd=3.0

F. SNOW LOADS (ITALIAN CODE)

• GROUND SNOW LOAD qk qk=1.50 kPa

• ROOF SHAPE FACTOR µ µ=0.8 (ANGLE<17°)

• ROOF SNOW LOAD qs=1.20 kPa

G. SNOW LOAD (US CODE)

• GROUND SNOW LOAD pg=1.68 kPa

• SNOW LOAD ON ROOF ps=1.06 kPa

H. WIND LOAD (ITALIAN CODE)

• REFERENCE WIND SPEED vb=25 m/s

• SITE CLASS II

• DYNAMIC COEFFICIENT cd=1.0

• WIND LOAD ON WINDWARD FACE

p=0.90 kPa

• WIND LOAD ON LEEWARD FACE

p=0.63 kPa

• WIND LOAD ON SIDES

p=0.54 kPa

DESIGN DATA

1. IL PROGETTO STRUTTURALE E' STATO REALIZZATO IN

CONFORMITA' ALLE SEGUENTI NORMATIVE

AMERICANE:

a. UFC 1-200-01 - REQUISITI GENERALI DELLE

STRUTTURE, GIUGNO 2019

b. UFC 3-301-01 - INGEGNERIA STRUTTURALE, 2019

c. IBC2018 - NORME INTERNAZIONALI DELLE

COSTRUZIONI, 2018

d. ASCE7-16 - CARICHI MINIMI DI PROGETTO PER

EDIFICI ED ALTRE STRUTTURE, 2016

e. ACI318-14 - REQUISITI DI PROGETTO PER

CALCESTRUZZO ARMATO, 2014

f. ANSI-AISC 341-16 - PROVVEDIMENTI ANTISISMICI

PER GLI EDIFICI IN ACCIAIO, 2016

g. AISC360-16 - SPECIFICHE PER EDIFICI IN ACCIAIO

STRUTTURALE, 2016

2. IL PROGETTO E' STATO ESEGUITO IN CONFORMITA'

ALLE SEGUENTI NORMATIVE ITALIANE

a. NORME TECNICHE PER IL CALCOLO, L'ESECUZIONE E IL COLLAUDO DI STRUTTURE IN

CALCESTRUZZO ARMATO NORMALE E

PRECOMPRESSO E DI STRUTTURE IN ACCIAIIO

(LEGGE 1086 - 5/11/1971)

b. NORME TECNICHE PER LE COSTRUZIONI IN ZONA

SISMICA (LEGGE 64 - 2/2/1974)

c. AGGIORNAMENTO ALLE NORME TECNICHE PER

LE COSTRUZIONI (DM 17/01/2018)

d. ISTRUZIONI PER L'APPLICAZIONE DELLE NUOVE

NORME TECNICHE PER LE COSTRUZIONI

(CIRC.7 - 21/02/2019)

3. CARICHI DI PROGETTO:

A. CARICHI PERMANENTI NON STRUTTURALI:

• 1.00 kPa

B. CARICHI VARIABILI (NORMATIVA ITALIANA):

• COPERTURA - CAT. H

0.50 kPa

• PIANO TERRA CAT. G

12.00 kPa

C. CARICHI VARIABILI (NORMATIVA US):

• COPERTURA

1.00 kPa

• PIANO TERRA

12.00 kPa

D. SISMA (NORMATIVA ITALIANA)

• CATEGORIA DI SUOLO

B

• VITA NOMINALE

Vn=50 ANNI

• CLASSE D'USO

II

• FATTORE D'USO

Cu=1.0

• VITA DI RIFERIMENTO

50 ANNI

• COEFFICIENTE DI ACELERAZIONE AL SUOLO

IN SLV ag/g=0.2386

• PERIODO DI RITORNO IN SLV

475 ANNI

E. SISMA (NORMATIVA US)

• ACCELERAZIONE SPETTRALE DI BREVE

PERIODO Ss=1.25

• ACCELERAZIONE AL PERIODO 1 SEC

S1=0.50

• CATEGORIA DI RISCHIO

II

• COEFFICIENTE DI IMPORTANZA

IE=1.00

• SISTEMA STRUTTURALE: TELAIO ORDINARIO

RESISTENTE A MOMENTO

• CATEGORIA TERRENO

C

• CATEGORIA SISMICA DI PROGETTO :

D

• COEFFICIENTE DI RISPOSTA E AMPLIF.

DEFORMAZIONI: R=3.5 , Cd=3.0

F. CARICO DA NEVE (NORMATIVA ITALIANA)

• CARICO AL SUOLO qk qk=1.50 kPa

• COEF.FORMA COPERTURA µ µ=0.8 (ANGOLO<17°)

• CARICO DA NEVE IN COPERTURA

qs=1.20 kPa

G. CARICO DA NEVE (NORMATIVA US)

• CARICO AL SUOLO

pg=1.68 kPa

• CARICO IN COPERTURA

ps=1.06 kPa

H. CARICO DA VENTO (NORMATIVA ITALIANA)

• VELOCITA' DI RIFERIMENTO

vb=25 m/s

• CATEGORIA DI SITO

II

• COEFFICIENTE DINAMICO

cd=1.0

• PRESSIONE PARETI SOPRAVENTO

p=0.90 kPa

• PRESSIONE PARETI SOTTOVENTO

p=0.63 kPa

• PRESSIONE PARETI LATERALI

p=0.54 kPa

• PRESSIONE MASSIMA COPERTURA

(SOLLEVAMENTO) p=1.00 kPa

• PRESSIONE MASSIMA COPERTURA

(COMPRESSIONE) p=0.36 kPa

DATI DI PROGETTO

1. CONCRETE AND STEEL STRUCTURE

DIMENSIONS ARE EXPRESSED IN MM.

2. VERTICAL ALTIMETRIC ELEVATIONS ARE

EXPRESSED IN M.

3. SPOT ELEVATION 0.00 AS INDICATED IN CIVIL

DRAWINGS

1. LE QUOTE DELLE STRUTTURE IN CALCESTRUZZO E

IN ACCIAIO SONO ESPRESSE IN MM

2. LE QUOTE ALTIMETRICHE SONO ESPRESSE IN M.

3. LA QUOTA RELATIVA 0.00 E' INDICATA NEI GRAFICI

CIVILI

UNIT OF MEASURE DIMENSION NOTE

NOTA SULLE UNITA' DI MISURA

H. CARICO DA VENTO (NORMATIVA US)

• VELOCITA' BASE DEL VENTO

148 Km/h

• CATEGORIA DI RISCHIO

II

• COEFFICIENTE DI ESPOSIZIONE

Kz=1.0

• COEFFICIENTE TOPOGRAFICO

Kzt=1.0

• COEFFICIENTE DIREZIONALE

Kd=0.85

• PRESSIONE PARETI

SOPRAVENTO

p=1.38 kPa

• PRESSIONE PARETI

SOTTOVENTO

p=0.86 kPa

• PRESSIONE PARETI LATERALI

p=1.27 kPa

• PRESSIONE MASSIMA

COPERTURA (SOLLEVAMENTO)

p=1.48 kPa

• PRESSIONE MASSIMA

COPERTURA (COMPRESSIONE)

p=0.10 kPa

4. FONDAZIONI

LE FONDAZIONI SONO DI TIPO DIRETTO, CON

SPESSORE 50 CM E 10 CM DI CALCESTRUZZO

MAGRO, CON INTRADOSSO A -1,5 M DAL

PIANO TERRA. CONSISTERANNO IN TRAVI

CONTINUE LUNGO IL PERIMETRO ED IN

CORRISPONDENZA DEL COLMO E DELLA

LINEA MEDIANA DELL'ASSE X (CON

LARGHEZZA 1600 MM IN DIREZIONE X, 2500

MM IN DIREZIONE Y), E PLINTI ISOLATI DI

DIMENSIONE 2500X2500 MMQ COLLEGATI DA

TIRANTI IN C.A. DI SEZIONE 300X500 MM.

I CARICHI DI PROGETTO SONO LIMITATI A 200

KN/MQ PER CONTENERE IL CEDIMENTO.

TUTTE LE STRUTTURE IN CALCESTRUZZO

INTERRATE SARANNO PROTETTE DA UNA

MEMBRANA BITUMINOSA RESISTENTE

ALL'ACQUA.

LA PROFONDITA' DI PENETRAZIONE DEL

GHIACCIO E' 600 MM AL DI SOTTO DEL P.C.

NON E' STATA RILEVATA ALCUNA FALDA

IDRICA PERMANENTE

5. LINEA VITA

a. PROGETTARE IN ACCORDO AI SEGUENTI

DOCUMENTI:

• OSHA 1926 S.PART M - 1926:502 -

CRITERI E PRATICA DEI SISTEMI

ANTICADUTA

• EM 3851-1,2008 MANUALE PER

REQUISITI DI SICUREZZA E SALUTE

• UNI-EN 795:2012 DISPOSITIVI

ANTICADUTA - DISPOSITIVI DI

ANCORAGGIO

• DL 81-08 SICUREZZA NEI LUOGHI DI

LAVORO

b. CARICHI MINIMI PER I DISPOSITIVI DI

ANCORAGGIO (REQUISITI OSHA):

• 13.3 KN FUNI E CORDINI RETRATTILI

CHE LIMITANO AUTOMATICAMENTE

LA CADUTA LIBERA A 60 cm;

• 22 KN FUNI E CORDINI RETRATTILI

CHE NON LIMITANO

AUTOMATICAMENTE LA CADUTA

LIBERA A 60 cm;

• 4.0 KN FORZA MASSIMA DI ARRESTO

PER ADDETTO CHE UTILIZZA LA

CINTURA;

• 8.0 KN FORZA MASSIMA DI ARRESTO

PER ADDETTO CHE UTILIZZA

IMBRAGATURA

• 22.0 KN CARICO MINIMO DI

ROTTURA DEL CORDINO

c. CARICHI MINIMI PER I DISPOSITIVI DI

ANCORAGGIO (REQUISITI UNI EN 795 ):

• 12.0 KN DISPOSITIVI DI

ANCORAGGIO CLASSE A E C

• MAX WIND LOAD ON ROOF (UPWDS)

p=1.00 kPa

• MIN WIND LOAD ON ROOF (DWNWDS)

p=0.36 kPa

H. WIND LOAD (US CODE)

• BASIC WIND SPEED

148 Km/h

• RISK CATEGORY

II

• VELOCITY PRESSURE EXP. COEFF.

Kz=1.0

• TOPOGRAPHIC FACTOR

Kzt=1.0

• DIRECTIONALITY FACTOR

Kd=0.85

• BUILDING IS PARTIALLY ENCLOSED

• WIND LOAD ON MWFRS

• WIND LOAD ON WINDWARD FACE

p=1.38 kPa

• WIND LOAD ON LEEWARD FACE

p=0.86 kPa

• WIND LOAD ON SIDES

p=1.27 kPa

• MAX WIND LOAD ON ROOF (UPWDS)

p=1.48 kPa

• MIN WIND LOAD ON ROOF (DWNWDS)

p=0.10 kPa

4. FOUNDATIONS

FOUNDATIONS MUST BE SHALLOW TYPE, 50 CM

THICK PLUS 10 CM THICK LEAN CONCRETE LAYER

LAID DOWN AT 1.50 M BELOW GROUND FLOOR

LEVEL. THEY MUST BE CONTINUOUS BEAMS ALONG

THE EDGE, ALONG THE CENTRAL PERPENDICULAR

ALIGNMENT AND UNDERNEATH THE COLUMNS OF

THE RIDGE ALIGNMENT (1600 MM WIDE, 2500 MM

WIDE FOR EDGE MEAMS IN Y-DIR), AND ISOLATED

PADS 2500X2500 SQ.MM, CONNECTED BY TIE BEAMS

300X500 MM

DESIGN BEARING PRESSURES ARE LIMITED TO 200

KN/SQM TO CONTAIN THE SETTLEMENT.

BURIED CONCRETE STRUCTURES MUST BE

PROTECTED THROUGH WATERPROOFING

MEMBRANE.

FROST DEPTH PENETRATION IS 600 MM BELOW

GROUND.

PERMANENT GROUND WATER TABLE IS NOT

EXPECTED.

5. FALL PROTECTION SYSTEM

a. DESIGN IN ACCORDANCE WITH THE FOLLOWING

DOCUMENTS:

• OSHA 1926 S.PART M - 1926:502 - FALL

PROTECTION SYSTEMS CRITERIA AND

PRACTICE

• EM 3851-1,2008 SAFETY AND HEALTH

REQUIREMENTS MANUAL

• UNI-EN 795:2012 PERSONAL FALL

PROTECTION EQUIPMENT - ANCHOR

DEVICES

• DL 81-08SAFEGUARDING HEALTH AND

SAFETY WITHIN WORKPLACES

b. MINIMUM DESIGN LOADS FOR ANCHOR POINTS

(OSHA REQUIREMENTS):

• 13.3 KN SELF RETS. LL AND LANYARD

LIMITING FREE FALL DISTANCE TO 2 FT;

• 22 KN SELF RETS. LL AND LANYARD NOT

LIMITING FREE FALL DISTANCE TO 2 FT;

• 4.0 KN MAX ARREST FORCE FOR EMPLOYEE

USING BODY BELT;

• 8.0 KN MAX ARREST FORCE FOR EMPLOYEE

USING BODY HARNESS;

• 22.0 KN MINIMUM LANYARD BREAKING

STRENGTH

c. MINIMUM DESIGN LOADS FOR ANCHOR POINTS

(UNI EN 795 REQUIREMENTS):

• 12.0 KN CLASS A AND C ANCHOR DEVICES

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

NO SCALE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

/1

/2

:3

:4

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

G E

N E

R A

L N

O T

E S

/2

S-002B

PD AA ES

S -0

B

G E

N E

R A

L N

O T

E S

/2

14121670 256 429

CONCRETE CONSTRUCTION NOTES

STEEL CONSTRUCTION NOTES NOTE DI COSTRUZIONE DEL'ACCIAIO

STEEL DECK NOTES

1. LA LAMIERA DI COPERTURA DOVRA' RISPETTARE

TUTTE LE LEGGI E NORMATIVE APPLICABILI IN ITALIA

2. FORNIRE UNA LAMIERA GRECATA IN ACCIAIO PER

CARICHI PESANTI CAPACE DI RESISTERE ALLE

SEGUENTI SOLLECITAZIONI DEL VENTO:

VERSO IL BASSO: 0.3 kPa VERSO L'ALTO: 2.16 kPa (ZONA 3)

1.92 kPa (ZONA 2)

1.44 kPa (ZONA 1)

1.00 kPa (ZONA 1')

3. INSTALLARE LA LAMIERA GRECATA IN MANIERA

TALE CHE I SOLCHI SIANO PERPENDICOLARI AGLI

ELEMENTI STRUTTURALI DI SUPPORTO. LA LAMIERA

DEVE POGGIARE ALMENO SU TRE SUPPORTI

LADDOVE POSSIBILE.

4. ELEMENTI LEGGERI COME CONTROSOFFITTI

LEGGERI, LAMPADE, CANALI POTRANNO ESSERE

COLLEGATE DIRETTAMENTE ALLA LAMIERA. NON

APPENDERE ALTRI ELEMENTI SENZA ESPLICITA

APPROVAZIONE.

5. LE APERTURE NELLA LAMIERA NON SONO

CONSENTITE SE NON SPECIFICAMENTE INDICATE

NEI GRAFICI O APPROVATE DALL'UFFICIALE

CONTRAENTE.

6. COLLEGARE LA LAMIERA ALLA STRUTTURA

PORTANTE SEGUENDO LE INDICAZIONI DEL

PRODUTTORE.

N O

T E

G E

N E

R A

LI

/2

1. TUTTI I PROFILI STRUTTURALI, BARRE, PIASTRE E

TIRANTI SARANNO CONFORMI ALLA UNI EN 10025, EN

10210, EN 10219-1, E AVRANNO TUTTI LA

MARCHIATURA CE. TUTTI I SOPRA CITATI ELEMENTI

AVRANNO LE SEGUENTI CARATTERISTICHE:

• ACCIAIO TIPO S 355, SNERVAMENTO fyk=355 MPa

• RESISTENZA ULTIMA ftk=530 MPa.

2. TUTTI I BULLONI PER LE UNIONI STRUTTURALI (UNI EN

898-1, UNI 5592:1968 E EN ISO 4016:2002) SARANNO DI

CLASSE 8.8, E AVRANNO PERTANTO LE SEGUENTI

PROPRIETA':

• SNERVAMENTO fyb=640 MPa

• RESISTENZA ULTIMA ftk=800 MPa

3. I TIRAFONDI SARANNO REALIZZATI IN CONFORMITA'

CON UNI EN 10025 CLASSE S355.

4. LE SALDATURE SARANNO DEL TIPO E70XX SE NON

DIVERSAMENTE INDICATO, E DOVRANO RIPRISTINARE

LA RESISTENZA COMPLETA DELL'ELEMENTO

COLLEGATO PIU' DEBOLE.

5. I FORI PER I BULLONI NON POTRANNO ESSERE

TAGLIATI O ALLARGATI IN SITU CON CANNELLO.

6. TUTTI GLI ELEMENTI IN ACCIAIO STRUTTURALE

DEVONO ESSERE ZINCATI A CALDO.

7. IN CASO DI FORMAZIONE DI RUGGINE, APPLICARE

UNO SPESSORE MINIMO DI VERNICE PROTETTIVA

PARI A 0.05 MM COME DA SPECIFICA 05 12 00

8. LA MALTA DA UTILIZZARE COME RIEMPIMENTO AL DI

SOTTO DELLE PIASTRE METALLICHE DOVRA' ESSERE

A RITIRO COMPENSATO, NON METALLICA,

PREMISCELATA, E DOVRà AVERE UNA RESISTENZA MINIMA A COMPRESSIONE DI 55 MPa.

1. CALCESTRUZZO:

A. CALCESTRUZZO NON STRUTTURALE

C12/15 - f'c=12 MPa (CILINDRICO)

B. CALCESTRUZZO STRUTTURALE IN OPERA

C35/45 - f'c=35 MPa (CILINDRICO)

CLASSE DI ESPOSIZIONE XC2

MASSIMA DIMENSIONE AGGREGATO 20 MM

CONSISTENZA S4

MASSIMO a/c = 0,5

C. CALCESTRUZZO IN OPERA PER SOLETTA CONTRO

TERRA

C30/35 - f'c=30 MPa (CILINDRICO)

CLASSE DI ESPOSIZIONE XC2

MASSIMA DIMENSIONE AGGREGATO 20 MM

CONSISTENZA S4

MASSIMO a/c = 0,5

2. ACCIAIO PER ARMATURE:

A. B450C, SNERVAMENTO fy=450 MPa

3. COPRIFERRI

I COPRIFERRI MINIMI DOVRANNO ESSERE NON

MINORI DI UN DIAMETRO, E COMUNQUE NON MINORI

DI QUANTO DI SEGUITO SPECIFICATO:

A. CALCESTRUZZO IN OPERA (NON

PRECOMPRESSO)

a. GETTATO CONTRO TERRA 75 MM

b. GETTATO CONTRO CASSERO ED ESPOSTO AGLI

AGENTI ATMOSFERICI 50 MM

c. GETTATO CONTRO CASSERO E NON ESPOSTO

AGLI AGENTI ATMOSFERICI:

• SOLETTE, TRAVETTI 25 MM

• PARETI (COPR. SULLA BARRA ORIZZ, EST.)

25 MM

• TRAVI E PILASTRI (ARMATURE

LONGITUDINALI, STAFFE) 40 MM

4. GLI INTERFERRI MINIMI SARANNO PARI AL DIAMETRO

DELLA BARRA MA IN NESSUN CASO INFERIORI A 25

MM.

5. TUTTI GLI SPIGOLI ESPOSTI DI CALCESTRUZZO

SARANNO SMUSSATI DI 15 MM SE NON

DIVERSAMENTE INDICATO.

6. NON SI ESEGUIRANNO GETTI DI CALCESTRUZZO

FINCHE' TUTTI GLI ELEMENTI E GLI SCAVI NON

SARANNO ISPEZIONATI DAL RESPONSABILE DEL

CONTROLLO DI QUALITA'. L'UFFICIALE CONTRAENTE

DOVRA' ESSERE AVVISATO DEL GETTO 24 ORE PRIMA

DELL'ISPEZIONE.

7. TUTTE LE ARMATURE SARANNO SALDAMENTE

BLOCCATE PER EVITARNE LO SPOSTAMENTO

DURANTE LE OPERAZIONI DI GETTO.

8. L'APPALTATORE DOVRA' UTILIZZARE I DISEGNI

STRUTTURALI INSIEME AI CIVILI, ARCHITETTONICI,

MECCANICI, IDRAULICI, ELETTRICI,

TELECOMUNICAZIONI E PROTEZIONE INCENDIO PER

PREPARARE I DISEGNI DI CANTIERE. DOVRA' INOLTRE

COORDINARE IL LAVORO DEI SUBAPPALTATORI PER

ATTRAVERSAMENTI, INSERTI, FORI, ANCORAGGI ETC.

I DISEGNI DI CANTIERE DOVRANNO INCLUDERE LE

FOROMETRIE MECCANICHE, ANTIINCENDIO,

ELETTRIHE, E TELECOMUNICAZIONI, PER EVITARE LA

REALIZZAZIONE DI FOROMETRIE NELLE STRUTTURE

IN CALCESTRUZZO DOPO LA LORO COSTRUZIONE.

9. LE CANALINE ELETTRICHE, GLI INSERTI, LE CASSETTE

ED ALTRI ELEMENTI DA ANNEGARE NEL

CALCESTRUZZO DOVRANNO ESSERE COORDINATI E

COLLOCATI PRIMA CHE IL CALCESTRUZZO SIA POSTO

IN OPERA. MANTENERE TRE DIAMETRI DI SPAZIO TRA

LE CANALINE. FARE RIFERIMENTO AI GRAFICI

MECCANICI ED ELETTRICI..

NOTE LAMIERA GRECATA IN ACCIAIONOTE DI COSTRUZIONE DEL CALCESTRUZZO

1. CONCRETE:

A. NON STRUCTURAL CONCRETE

C12/15 - f'c=12 MPa (CYLINDRICAL)

B. STRUCTURAL CAST-IN-PLACE CONCRETE

C35/45 - f'c=35 MPa (CYLINDRICAL)

EXPOSURE CLASS XC2

MAX SIZE AGGREGATE 20 MM

CONSISTENCY S4

MAX w/c = 0,5

C. CAST-IN- PLACE CONCRETE FOR SLAB ON GRADE

C30/35 - f'c=30 MPa (CYLINDRICAL)

EXPOSURE CLASS XC2

MAX SIZE AGGREGATE 20 MM

CONSISTENCY S4

MAX w/c = 0,5

2. STEEL FOR REINFORCEMENT:

A. B450C, YIELD STRENGTH

fy=450 MPa

3. CONCRETE COVER

A. CONCRETE THICKNESS COVERING

REINFORCEMENT MUST NOT BE LESS THAN ONE

BAR DIAMETER AND NOT LESS THAN SPECIFIED

IN THE EXAMPLES LISTED BELOW.

a. CONCRETE CAST AGAINST EARTH

75 MM

b. CONCRETE CAST AGAINST FORMS AND

EXPOSED TO WEATHER 50 MM

c. CONCRETE CAST AGAINST FORMS AND NOT

EXPOSED TO WEATHER:

• SLABS, JOISTS,

25 M

• WALLS (COVER ON HORIZ. EXT. BARS)

25 MM

• BEAMS AND COLUMNS (PRIMARY

REINFORCEMENT, STIRRUPS) 40 MM

4. MINIMUM CLEAR SPACING BETWEEN PARALLEL

REINFORCING BARS MUST BE GREATER THAN RE-BAR

DIAMETER BUT NOT LESS THAN 25MM.

5. EXPOSED CONCRETE EDGES MUST BE CHAMFERED

15 MILLIMETERS UNLESS OTHERWISE SHOWN.

6. NO CONCRETE MAY BE PLACED UNTIL EMBEDDED

WORK AND EXCAVATION HAVE BEEN INSPECTED BY

THE QUALITY CONTROL ORGANIZATION. THE

CONTRACTING OFFICER MUST BE NOTIFIED 24 HOURS

IN ADVANCE OF THE INSPECTION.

7. REINFORCING STEEL MUST BE HELD SECURELY IN

PLACE TO PREVENT DISLOCATION DURING

CONCRETE POURING OPERATIONS.

8. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH

CIVIL, ARCHITECTURAL, MECHANICAL, PLUMBING,

FIRE PROTECTION AND ELECTRICAL DRAWINGS IN

ORDER TO PREPARE SHOP DRAWINGS. COORDINATE

THE REQUIREMENTS OF THE WORK OF OTHER

TRADES AS TO SLEEVES, INSERTS, HOLES, HANGERS,

CHASES, ANCHORS, ETC. SHOP DRAWINGS MUST

INCLUDE ALL HOLES FOR MECHANICAL, FP,

ELECTRICAL AND TELECOMM SERVICE

PENETRATIONS SO THAT NO HOLES MAY BE ADDED

AFTER THE CONSTRUCTION OF THE CONCRETE

STRUCTURES.

9. ELECTRICAL CONDUIT, INSERTS, BOXES AND OTHER

ITEMS THAT ARE BEING EMBEDDED IN CONCRETE

WORK MUST BE COORDINATED AND PLACED BEFORE

CONCRETE IS PLACED. MAINTAIN THREE DIAMETERS

CLEARANCE BETWEEN CONDUITS. SEE MECHANICAL

AND ELECTRICAL DWGS.

1. STRUCTURAL SHAPES, BARS, PLATES AND RODS

MUST CORRESPOND TO UNI STANDARD EN 10025, EN

10210, EN 10219-1 ALL HAVING CE MARKING. SHAPES

MUST CORRESPOND TO THE FOLLOWING:

• STEEL TYPE S355, YIELDING fyk=355 MPa

• ULTIMATE TENSILE STRENGTH ftk=530 MPa.

2. FASTENERS FOR STRUCTURAL CONNECTIONS (UNI EN

898-1 AND UNI 5592:1968 AND EN ISO 4016:2002) MUST

CORRESPOND TO THE FOLLOWING:

• CLASS 8.8, YIELDING fyb=640 MPa

• TENSILE STRENGTH ftk=800 MPa

3. ANCHOR BOLTS MUST BE CONFORMING TO UNI EN

10025 CLASS S355.

4. WELDINGS TYPE E70XX IF NOT DIFFERENTLY

INDICATED. WELDS MUST DEVELOP THE FULL

STRENGTH OF THE WEAKER CONNECTED MEMBER.

5. BOLT HOLES MAY NOT BE CUT OR ENLARGED BY

FLAME CUTTING IN THE FIELD.

6. STEEL MEMBERS MUST BE HOT-DIP GALVANIZED

7. IF FLASH RUSTING OCCURS, APPLY PRIMER TO A

MINIMUM DRY FILM THICKNESS OF 0.05 MM, IN

ACCORDANCE WITH SPEC 05 12 00.

8. GROUT USED UNDER BEARING PLATES MUST BE NON

SHRINK, NON METALLIC, PRE-MIXED GROUT AND HAVE

A MINIMUM 55 MPa COMPRESSIVE STRENGTH

1. STEEL DECK MUST COMPLY WITH REQUIREMENTS

OF APPLICABLE ITALIAN NORMS AND CODES.

2. PROVIDE HEAVY DUTY STEEL DECK TO RESIST THE

FOLLOWING WIND LOADING CONDITIONS:

DOWNWARDS: 0.30 kPa UPWARDS: 2.16 kPa (ZONE 3)

1.92 kPa (ZONE 2)

1.44 kPa (ZONE 1)

1.00 kPa (ZONE 1')

3. ROOF DECK MUST BE INSTALLED SO THAT FLUTES

RUN PERPENDICULAR TO FRAMING MEMBERS. DECK

MUST SPAN ON THREE SUPPORTS MIN. WHERE

POSSIBLE.

4. LIGHTWEIGHT ITEMS: LW CEILINGS, DUCTS, LIGHT

FIXTURES ETC., MAY BE HUNG FROM DECK. DO NOT

HANG OTHER ITEMS FROM ROOF DECK WITHOUT

APPROVAL.

5. OPENINGS IN DECK ARE NOT ALLOWED IF NOT

SPECIFICALLY INDICATED ON DRAWINGS OR

APPROVED BY THE CONTRACTING OFFICER.

6. FASTEN STEEL DECK TO THE MAIN FRAMING IN

ACCORDANCE TO MANUFACTURER'S

INSTRUCTIONS.

1. FALL PROTECTION SYSTEM MUST BE DESIGNED BY

A REGISTERED ENGINEER. CONTRACTOR MUST

SUBMIT DRAWINGS AND CALCULATIONS TO USG

AND DOR SIGNED AND SEALED FOR APPROVAL.

2. CONTRACTOR MUST SUBMIT TECHNICAL DATA

SHEET THAT CERTIFIES COMPLIANCE TO UNI EN 795,

OR OSHA REQUIREMENTS, WHICHEVER IS MORE

STRINGENT.

3. ALL DIMENSIONS INDICATED IN CONSTRUCTIONS

DETAILS MUST BE VERIFIED WITH THE ACTUAL

GEOMETRY PRIOR TO PROVIDE FPS DESIGN.

4. THE ANALYSIS IS REFERRED TO A SPECIFIC

GEOMETRY OF THE FALL PROTECTION SYSTEM

DEVICE SUPPORT SYSTEM, AND MAY VARY

ACCORDING TO THE SPECIFIC PRODUCT SELECTED

BY THE CONTRACTOR.

5. EACH UNI EN 795 CLASS C DEVICE MUST BE

PROVIDED WITH AN ENERGY DISSIPATING DEVICE

AS FORESEEN BY MANUFACTURER'S TECHNICAL

DATA SHEET, UNLESS OTHERWISE DISPOSED IN THE

SAME DOCUMENT.

6. AFTER COMPLETION OF FPS INSTALLATION,

PROVIDE A COMPLETE TECHNICAL BROCHURE

INCLUDING MAINTENANCE MANUAL TO THE

CONTRACTING OFFICER. AN ACCESS SIGN MUST BE

POSITIONED IN PROXIMITY OF ROOF ACCESS.

7. ANCHORAGE EFFICIENCY OF THE FPS MUST BE

TESTED PRIOR TO PUT IN SERVICE THE SYSTEM.

FALL PROTECTION SYSTEM NOTES

1. LE LINEE VITA DEVONO ESSERE PROGETTATE DA

UN INGEGNERE ABILITATO. L'APPALTATORE DOVRA'

SOTTOMETTERE PER APPROVAZIONE AD USG E DOR

DISEGNI ESECUTIVI E RELAZIONE DI CALCOLO.

2. L'APPALTATORE DOVRA' SOTTOMETTERE I DATI

TECNICI CHE CERTIFICHINO IL RISPETTO ALLA UNI

795, O AI REQUISITI OSHA LADDOVE PIU'

RESTRITTIVI.

3. TUTTE LE DIMENSIONI INDICATE NEI PARTICOLARI

COSTRUTTIVI DOVRANNO ESSERE VERIFICATE ED

ADEGUATE ALLA GEOMETRIA EFFETTIVA PRIMA DI

PROVEDERE AL PROGETTO DELLA LINEA VITA.

4. L'ANALISI E' RIFERITA AD UNA SPECIFICA

GEOMETRIA DEL SISTEMA ANTICADUTA, E POTRA'

VARIARE IN DIPENDENZA DELLO SPECIFICO

PRODOTTO SELEZIONATO DALL'APPALTATORE.

5. OGNI DISPOSITIVO UNI EN 795 CLASSE C DOVRA'

ESSERE EQUIPAGGIATO CON UN DISPOSITIVO DI

DISSIPAZIONE DELL'ENERGIA COME PREVISTO FAL

MANUALE TECNICO DEL PRODUTTORE, A MENO CHE

NON SIA DIVERSAMENTE DISPOSTO NELLO STESSO

DOCUMENTO.

6. DOPO AVER INSTALLATO LA LINEA VITA FORNIRE

ALL'UFFICIALE CONTRAENTE DOCUMENTAZIONE

TECNICA COMPLETA, INCLUSO IL MANUALE DI

MANUTENZIONE. UN CARTELLO DI ACCESSO DOVRA'

ESSERE POSIZIONATO IN PROSSIMITA'

DELL'ACCESSO AL TETTO.

7. L'EFFICIENZA DEI DISPOSITIVI DI ANCORAGGIO

DOVRA' ESSERE VERIFICATA PRIMA DI METTERE IN

FUNZIONE IL SISTEMA.

NOTE PER LE LINEE VITA

B1

SB201B

B1

SB202B

A1

SB202B

A1

SB201B

2 3 4

A

C

D

E

F

G

5 6 7 8 91

8500 7750 7750 7750 7750 7750 7750 8500

63500

SB102B

B1

SB103B

B1

SB104B

B1

SB105B

B1

SF401B

C3

B

66000

1 : 200

OVERALL FOUNDATION PLAN

B1 PIANTA GENERALE DELLE FONDAZIONI

KEY PLAN

PIANTA DI RIFERIMENTO

A B

C D

5 0 5 10 15

1:200

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

1 : 200

/1

/2

:3

:5

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

O V

E R

A

LL

F O

U N

D A

T

IO

N P

LA

N

SB101B

PD AA ES

S B

1B

O V

E R

A

LL

F O

U N

D A

T

IO

N P

LA

N

14121671 257 429

NORD DELLA PIANTA

PLAN NORTH

1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001B AND

S002B.

PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO

ALLE TAVOLE S001B E S002B.

2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO

ARCHITECTURAL AND CIVIL DRAWINGS.

PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE

RIFERIMENTO AI DISEGNI ARCHITETTONICI E CIVILI.

GENERAL SHEET NOTES:

NOTE GENERALI DEL DISEGNO :

P

IA

N T

A G

E N

E R

A L

E F

O N

D A

Z

IO

2 3 4

E

F

G

2500 7100

A1

SF301B

A1

SF301B

6800 1600

-1000

-1000 -1000

-1000

-1000

8500 7750 7750 7750

-1000

-1000

MATCHLINE - SEE B1 ON SHEET SB104B

M A

T C

H

LI

N E

S

E E

B

O N

S H

E E

T S

B

3B

SK551

B1

B4

SK551

B4

SK551

2180 6000 2000 6000 1500 6000 2000 6000 1500

SK552

C3

SK555

C1

A1

SR303B

A1

SR303B

B3

SK551

B3

SK551

300 7450 300 7450 300

2500 5250 2500

1 : 100SB101B

FOUNDATION PLAN - AREA A

B1 PIANTA FONDAZIONI - AREA A

1 0 1 2 3 4 5 6 7 8 9

1:100

KEY PLAN

PIANTA DI RIFERIMENTO

A B

C D

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

1 : 100

/1

/2

:3

:5

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

F O

U N

D A

T

IO

N P

LA

N

A

R E

A A

SB102B

PD AA ES

S B

2B

F O

U N

D A

T

IO

N P

LA

N

A

R E

A A

14121672 258 429

NORD DELLA PIANTA

PLAN NORTH

KEY #

KEYED NOTES / NOTE CHIAVE

ENGLISH NOTE NOTA ITALIANA

1 COLUMN HEB320 COLONNA HEB320

2 R.C. FOOTING 2500x2500x500 PLINTO IN C.A. 2500x2500x500

3 R.C. TIE BEAM 300x500 TRAVE DI COLLEGAMENTO IN C.A. 300x500

4 R.C. FOUNDATION BEAM 1600x500 TRAVE DI FONDAZIONE IN C.A. 1600x500

5 R.C. FOUNDATION BEAM 2500x500 TRAVE DI FONDAZIONE IN C.A. 2500x500

6 R.C. EXTERIOR WALL (h=1220 mm) MURO ESTERNO IN C.A. (h=1220 mm)

7 R.C. INTERIOR WALL (h=2200 mm) MURO INTERNO IN C.A. (h=2200 mm)

8 SERVICE AREA AREA SERVIZI

9 PROVIDE STEEL COLUMN BASE

PLATE PRIOR TO CASTING THE

CORNER WALL

INSTALLARE IL PILASTRO IN ACCIAIO

PRIMA DI GETTARE IL MURO D'ANGOLO

10 BOLLARD DISSUASORE

11 REMOVABLE BOLLARD DISSUASORE RIMOVIBILE

1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001B AND

S002B.

PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO

ALLE TAVOLE S001B E S002B.

2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO

ARCHITECTURAL AND CIVIL DRAWINGS.

PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE

RIFERIMENTO AI DISEGNI ARCHITETTONICI E CIVILI.

3. COORDINATE OPENING IN CONCRETE WALL FOR UTILITY PENETRATIONS

REFER TO MECHANICAL, ELECTRICAL AND FIRE DRAWINGS PRIOR TO

SUBMITTAL OF REBAR SHOP DRAWINGS.

COORDINARE LE APERTURE NEI MURI IN C.A. PER ATTRAVERSAMENTI DI

LINEE DI SERVIZIO. FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E

ANTINCENDIO PRIMA DI SOTTOMETTERE I DISEGNI ESECUTIVI DELLE BARRE

DI ARMATURA.

GENERAL SHEET NOTES:

NOTE GENERALI DEL DISEGNO :

P

IA

N T

A F

O N

D A

Z

IO

N I -

A R

E A

A

LI

N

E A

D I C

O

LL

E G

A M

E N

T O

V

E D

I B

S U

T A

V . S

B

3B

LINEA DI COLLEGAMENTO - VEDI B1 SU

TAV. SB104B

F

G

5 6 7 8 9

7750 7750 7750 8500

2500710030074503007450300

B1

SF301B

B1

SF301B

1600 6800

-1000

-1000

-1000

-1000

-1000

-1000-1000

-1000

M A

T C

H

LIN

E

S E

E B

1 O N

S H

E E

T S

B 102B

MATCHLINE - SEE B1 ON SHEET SB105B

1500 6000 2000 6000 1500 6000 2000 6000 2180

2500 5250 2500

1 : 100SB101B

FOUNDATION PLAN - AREA B

B1 PIANTA FONDAZIONI - AREA B

1 0 1 2 3 4 5 6 7 8 9

1:100

KEY PLAN

PIANTA DI RIFERIMENTO

A B

C D

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

1 : 100

/1

/2

:3

:5

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

F O

U N

D A

T

IO

N P

LA

N

A

R E

A B

SB103B

PD AA ES

S B

3B

F O

U N

D A

T

IO

N P

LA

N

A

R E

A B

14121673 259 429

NORD DELLA PIANTA

PLAN NORTH

KEY #

KEYED NOTES / NOTE CHIAVE

ENGLISH NOTE NOTA ITALIANA

1 COLUMN HEB320 COLONNA HEB320

2 R.C. FOOTING 2500x2500x500 PLINTO IN C.A. 2500x2500x500

3 R.C. TIE BEAM 300x500 TRAVE DI COLLEGAMENTO IN C.A. 300x500

4 R.C. FOUNDATION BEAM 1600x500 TRAVE DI FONDAZIONE IN C.A. 1600x500

5 R.C. FOUNDATION BEAM 2500x500 TRAVE DI FONDAZIONE IN C.A. 2500x500

6 R.C. EXTERIOR WALL (h=1220 mm) MURO ESTERNO IN C.A. (h=1220 mm)

7 R.C. INTERIOR WALL (h=2200 mm) MURO INTERNO IN C.A. (h=2200 mm)

8 PROVIDE STEEL COLUMN BASE PLATE

PRIOR TO CASTING THE CORNER

WALL

INSTALLARE IL PILASTRO IN ACCIAIO

PRIMA DI GETTARE IL MURO D'ANGOLO

9 BOLLARD DISSUASORE

10 REMOVABLE BOLLARD DISSUASORE RIMOVIBILE

1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001B AND

S002B.

PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO

ALLE TAVOLE S001B E S002B.

2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO

ARCHITECTURAL AND CIVIL DRAWINGS.

PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE

RIFERIMENTO AI DISEGNI ARCHITETTONICI E CIVILI.

3. COORDINATE OPENING IN CONCRETE WALL FOR UTILITY PENETRATIONS

REFER TO MECHANICAL, ELECTRICAL AND FIRE DRAWINGS PRIOR TO

SUBMITTAL OF REBAR SHOP DRAWINGS.

COORDINARE LE APERTURE NEI MURI IN C.A. PER ATTRAVERSAMENTI DI

LINEE DI SERVIZIO. FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E

ANTINCENDIO PRIMA DI SOTTOMETTERE I DISEGNI ESECUTIVI DELLE BARRE

DI ARMATURA.

GENERAL SHEET NOTES:

NOTE GENERALI DEL DISEGNO :

P

IA

N T

A F

O N

D A

Z

IO

N I -

A R

E A

B

LINEA DI COLLEGAMENTO - VEDI B1 SU

TAV. SB105B

LIN

E

A D

I C O

LLE

G

A M

E N

T O

V

E D

I B

S U

T A

V . S

B 102B

C

D

8500 7750 7750 7750

300 7450 300 7450 300

A1

SF302B

A1

SF302B

A1

SF301B

A1

SF301B

6800 1600

-1000

-1000

-1000

-1000

B

-1000-1000-1000

SK554

A1

MATCHLINE - SEE B1 ON SHEET SB102B

M A

T C

H

LI

N E

S

E E

B

O N

S H

E E

T S

B

5B

2180 6000 2000 6000 1500 6000 2000 6000 1500

-1000

2500 5250 2500

3800 100

2500 7100

1 : 100SB101B

FOUNDATION PLAN - AREA C

B1 PIANTA FONDAZIONI - AREA C

1 0 1 2 3 4 5 6 7 8 9

1:100

KEY PLAN

PIANTA DI RIFERIMENTO

A B

C D

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

1 : 100

/1

/2

:3

:5

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

F O

U N

D A

T

IO

N P

LA

N

A

R E

A C

SB104B

PD AA ES

S B

4B

F O

U N

D A

T

IO

N P

LA

N

A

R E

A C

14121674 260 429

NORD DELLA PIANTA

PLAN NORTH

KEY #

KEYED NOTES / NOTE CHIAVE

ENGLISH NOTE NOTA ITALIANA

1 COLUMN HEB320 COLONNA HEB320

2 R.C. FOOTING 2500x2500x500 PLINTO IN C.A. 2500x2500x500

3 R.C. TIE BEAM 300x500 TRAVE DI COLLEGAMENTO IN C.A. 300x500

4 R.C. FOUNDATION BEAM 1600x500 TRAVE DI FONDAZIONE IN C.A. 1600x500

5 R.C. FOUNDATION BEAM 2500x500 TRAVE DI FONDAZIONE IN C.A. 2500x500

6 R.C. EXTERIOR WALL (h=1220 mm) MURO ESTERNO IN C.A. (h=1220 mm)

7 R.C. INTERIOR WALL (h=2200 mm) MURO INTERNO IN C.A. (h=2200 mm)

8 SERVICE AREA AREA SERVIZI

9 PROVIDE STEEL COLUMN BASE

PLATE PRIOR TO CASTING THE

CORNER WALL

INSTALLARE IL PILASTRO IN ACCIAIO

PRIMA DI GETTARE IL MURO D'ANGOLO

10 BOLLARD DISSUASORE

1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001B AND

S002B.

PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO

ALLE TAVOLE S001B E S002B.

2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO

ARCHITECTURAL AND CIVIL DRAWINGS.

PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE

RIFERIMENTO AI DISEGNI ARCHITETTONICI E CIVILI.

3. COORDINATE OPENING IN CONCRETE WALL FOR UTILITY PENETRATIONS

REFER TO MECHANICAL, ELECTRICAL AND FIRE DRAWINGS PRIOR TO

SUBMITTAL OF REBAR SHOP DRAWINGS.

COORDINARE LE APERTURE NEI MURI IN C.A. PER ATTRAVERSAMENTI DI

LINEE DI SERVIZIO. FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E

ANTINCENDIO PRIMA DI SOTTOMETTERE I DISEGNI ESECUTIVI DELLE BARRE

DI ARMATURA.

GENERAL SHEET NOTES:

NOTE GENERALI DEL DISEGNO :

P

IA

N T

A F

O N

D A

Z

IO

N I -

A R

E A

C

LINEA DI COLLEGAMENTO - VEDI B1 SU TAV. SB102B

LI

N

E A

D I C

O

LL

E G

A M

E N

T O

V

E D

I B

U

V

. S B

5B

D

5 6 7 8 9

7750 7750 7750 8500

2500710030074503007450300

B1

SF301B

B1

SF301B

A1

SF302B

A1

SF302B

1600 6800

-1000

-1000

-1000

-1000

-1000 -1000

B

M A

T C

H

LIN

E

S E

E B

1 O N

S H

E E

T S

B 104B

MATCHLINE - SEE B1 ON SHEET SB103B

1500 6000 2000 6000 1500 6000 2000 6000 2180

2500 5250 2500

1 : 100SB101B

FOUNDATION PLAN - AREA D

B1 PIANTA FONDAZIONI - AREA D

KEY PLAN

PIANTA DI RIFERIMENTO

A B

C D

1 0 1 2 3 4 5 6 7 8 9

1:100

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

1 : 100

/1

/2

:3

:5

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

F O

U N

D A

T

IO

N P

LA

N

A

R E

A D

SB105B

PD AA ES

S B

5B

F O

U N

D A

T

IO

N P

LA

N

A

R E

A D

14121675 261 429

NORD DELLA PIANTA

PLAN NORTH

KEY #

KEYED NOTES / NOTE CHIAVE

ENGLISH NOTE NOTA ITALIANA

1 COLUMN HEB320 COLONNA HEB320

2 R.C. FOOTING 2500x2500x500 PLINTO IN C.A. 2500x2500x500

3 R.C. TIE BEAM 300x500 TRAVE DI COLLEGAMENTO IN C.A. 300x500

4 R.C. FOUNDATION BEAM 1600x500 TRAVE DI FONDAZIONE IN C.A. 1600x500

5 R.C. FOUNDATION BEAM 2500x500 TRAVE DI FONDAZIONE IN C.A. 2500x500

6 R.C. EXTERIOR WALL (h=1220 mm) MURO ESTERNO IN C.A. (h=1220 mm)

7 R.C. INTERIOR WALL (h=2200 mm) MURO INTERNO IN C.A. (h=2200 mm)

8 PROVIDE STEEL COLUMN BASE

PLATE PRIOR TO CASTING THE

CORNER WALL

INSTALLARE IL PILASTRO IN ACCIAIO

PRIMA DI GETTARE IL MURO D'ANGOLO

9 BOLLARD DISSUASORE

1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001B AND

S002B.

PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO

ALLE TAVOLE S001B E S002B.

2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO

ARCHITECTURAL DRAWINGS.

PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE

RIFERIMENTO AI DISEGNI ARCHITETTONICI.

3. COORDINATE OPENING IN CONCRETE WALL FOR UTILITY PENETRATIONS

REFER TO MECHANICAL, ELECTRICAL AND FIRE DRAWINGS PRIOR TO

SUBMITTAL OF REBAR SHOP DRAWINGS.

COORDINARE LE APERTURE NEI MURI IN C.A. PER ATTRAVERSAMENTI DI

LINEE DI SERVIZIO. FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E

ANTINCENDIO PRIMA DI SOTTOMETTERE I DISEGNI ESECUTIVI DELLE BARRE

DI ARMATURA.

GENERAL SHEET NOTES:

NOTE GENERALI DEL DISEGNO :

P

IA

N T

A F

O N

D A

Z

IO

N I -

A R

E A

D

LINEA DI COLLEGAMENTO - VEDI B1 SU TAV. SB103B

LIN

E

A D

I C O

LLE

G

A M

E N

T O

V

E D

I B 1 S

U

V . S

B 104B

C

D

E

F

G

5 6 7 8 91

B

4390 4390 3875 3875 3875 3875 3875 3875 3875 3875 3875 3875 4390 4390

16250 15500 15500 16250

SK552

B4

SK552

B5

SR305B

C1

CTJ

CTJ

CTJ CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJCTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CTJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

3875 3875

CJ CJ CJ

CJ CJ CJ

CTJ CTJ CTJ CTJ

CTJ CTJ CTJ CTJ

1580 1500

1500 1500

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

1 : 200

/1

/2

:3

:5

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

S

LA

B O

N G

R A

D E

P

LA

N

SB106B

PD AA ES

S B

6B

S

LA

B O

N G

R A

D E

P

LA

N

14121676 262 429

1 : 200

SLAB ON GRADE PLAN

B1 PIANTA SOLETTA A TERRA

5 0 5 10 15

1:200

KEY #

KEYED NOTES / NOTE CHIAVE

ENGLISH NOTE NOTA ITALIANA

1 R.C. SLAB ON GRADE THICK. 220 mm SOLETTA IN C.A. SPESSORE 220 mm

2 CONSTRUCTION JOINT (CJ).

SEE DETAIL A2 ON SHEET SK552

GIUNTO DI COSTRUZIONE.

VEDERE DETTAGLIO A2 ALLA TAVOLA SK552

3 CONTROL JOINT (CTJ).

SEE DETAIL A1 ON SHEET SK552

GIUNTO DI CONTROLLO.

VEDERE DETTAGLIO A1 ALLA TAVOLA SK552

4 EXPANSION JOINT (CEJ) BEETWEEN

MAT SLAB AND R.C. WALL FOR FULL

HIGHT OF SLAB. SEE DETAIL A3 ON

SHEET SK552

GIUNTO DI ESPANSIONE TRA LA SOLETTA

ED I MURI IN C.A. PER TUTTO LO SPESSORE

DELLA SOLETTA. VEDERE DETTAGLIO A3

ALLA TAVOLA SK552.

5 COLUMN EXPANSION/ISOLATION

JOINT. SEE DETAIL A3 ON SHEET

SK552

GIUNTO DI ESPANSIONE/ISOLAMENTO

DELLA COLONNA. VEDERE DETTAGLIO A3

ALLA TAVOLA SK552

6 THICKENED EDGE. SEE SECTION C1

ON SHEET SK552

BORDO RINGROSSATO. VEDERE SEZIONE

C1 ALLA TAVOLA SK552

7 R.C. APRON AT PEDESTRIAN DOOR.

SEE DETAIL B1 ON SHEET SK567

PIAZZOLA IN C.A. AGLI INGRESSI PEDONALI.

VEDERE DETTAGLIO B1 ALLA TAVOLA SK567

8 R.C. APRON AT ROLL UP DOOR. SEE

DETAIL C1 ON SHEET SK567

PIAZZOLA IN C.A. AI VARCHI CARRABILI.

VEDERE DETTAGLIO C1 ALLA TAVOLA SK567

9 STANDARD BOLLARD - INTERNAL.

SEE DETAL A2 ON SHEET SK567

DISSUASORE STANDARD - INTERNO.

VEDERE DETTAGLIO A2 ALLA TAVOLA SK567

10 STANDARD BOLLARD - EXTERNAL.

SEE DETAL A1 ON SHEET SK567

DISSUASORE STANDARD - ESTERNO.

VEDERE DETTAGLIO A1 ALLA TAVOLA SK567

11 REMOVABLE BOLLARD - SEE DETAL

A3 ON SHEET SK567

DISSUASORE RIMOVIBILE - VEDERE

DETTAGLIO A3 ALLA TAVOLA SK567

1 1

NORD DELLA PIANTA

PLAN NORTH

1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001B AND

S002B.

PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO

ALLE TAVOLE S001B E S002B.

2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO

ARCHITECTURAL AND CIVIL DRAWINGS.

PER IL POSIZIONAMENTO DEI MURI IM C.A. E DEI DISSUASORI, FARE

RIFERIMENTO AI DISEGNI ARCHITETTONICI E CIVILI.

GENERAL SHEET NOTES:

NOTE GENERALI DEL DISEGNO :

5 4

6 6

P

IA

N T

A S

O

LE

T T

A A

T E

R

KEY PLAN

PIANTA DI RIFERIMENTO

A B

C D

FOUND

-1000

EAVE TOS

FIRST FLOOR

23456789 1

DOOR

L.C.

-1500

85007750775077507750775077508500

1170 6240 1760 6240 1260

SK561

A1

SK562

A1

SK565

A1

SK563

A4

FOUND

-1000

EAVE TOS

FIRST FLOOR

2 3 4 5 6 7 8 91

DOOR

L.C.

-1500

8500 7750 7750 7750 7750 7750 7750 8500

1170 6240 1760 6240 1260

SK565

D1

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

1 : 100

/1

/2

:3

:0

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

E

LE

V A

T

IO

N O

N A

X

IS

SB201B

PD AA ES

S B

1B

E

LE

V A

T

IO

N O

N A

X

IS

14121677 263 429

1 : 100SB101B

ELEVATION ON AXIS

B1 PROSPETTO SU ASSE G

1 : 100SB101B

ELEVATION ON AXIS

A1 PROSPETTO SU ASSE A

KEY #

KEYED NOTES / NOTE CHIAVE

ENGLISH NOTE NOTA ITALIANA

1 COLUMN HEB320 COLONNA HEB320

2 BEAM HEB220 TRAVE HEB220

3 COLUMN IPE160 COLONNA IPE160

4 GIRT UPN200 ARCARECCIO UPN200

5 SHS 150x16 TRAVE TUBOLARE 150x16

6 OVERHEAD DOOR. SEE

ARCHITECTURAL DRAWINGS

PORTA BASCULANTE. VEDERE I

DISEGNI ARCHITETTONICI

2 4

2 4

1 0 1 2 3 4 5 6 7 8 9

1:100

34 5 1

345 1

G

A

1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001B AND

S002B.

PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO

ALLE TAVOLE S001B E S002B.

2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO

ARCHITECTURAL DRAWINGS.

PER IL POSIZIONAMENTO DEI MURI IM C.A. E DEI DISSUASORI, FARE

RIFERIMENTO AI DISEGNI ARCHITETTONICI.

GENERAL SHEET NOTES:

NOTE GENERALI DEL DISEGNO :

P R

O S

P E

T T

I S U

A S

S I A

E G

A A

N D

G

GRONDA TOS

LIV. PORTE

PRIMO PIANO

FOND.

MAGRONE

GRONDA TOS

LIV. PORTE

PRIMO PIANO

FOND.

MAGRONE

EAVE TOS

FIRST FLOOR

A C D E F G

DOOR

B

L.C.

-1500

RIDGE TOS

9250 8750 8750 8750 8750 9250

1340 2900 2500 2900 2900 2900 2900 2000 2500 2500 2610 1340

V A

R

13403410 20002000

SK563

A1

540 540

2900 2000 2500 250025002500

FOUND

-1000

EAVE TOS

FIRST FLOOR

ACDEFG

DOOR

B

L.C.

-1500

RIDGE TOS

9250 8750 8750 8750 8750 9250

3100 3100

1340 2365 2365 2140 1110 2140 3060 2140 2310 2900 2900

V A

R

3060 1340 540540 1340 3090

SK565

B1

1340 2900 2900

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

1 : 100

/1

/2

:3

:2

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

E

LE

V A

T

IO

N O

N A

X

IS

SB202B

PD AA ES

S B

2B

E

LE

V A

T

IO

N O

N A

X

IS

14121678 264 429

1 : 100SB101B

ELEVATION ON AXIS

B1 PROSPETTO SU ASSE 9

1 : 100SB101B

ELEVATION ON AXIS

A1 PROSPETTO SU ASSE 1

KEY #

KEYED NOTES / NOTE CHIAVE

ENGLISH NOTE NOTA ITALIANA

1 COLUMN HEB320 COLONNA HEB320

2 BEAM IPE400 TRAVE IPE400

3 COLUMN IPE160 COLONNA IPE160

4 GIRT UPN200 ARCARECCIO UPN200

5 SHS 150x16 TRAVE TUBOLARE 150x16

1 0 1 2 3 4 5 6 7 8 9

1:100

13 5

1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001B AND

S002B.

PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO

ALLE TAVOLE S001B E S002B.

2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO

ARCHITECTURAL DRAWINGS.

PER IL POSIZIONAMENTO DEI MURI IM C.A. E DEI DISSUASORI, FARE

RIFERIMENTO AI DISEGNI ARCHITETTONICI.

GENERAL SHEET NOTES:

NOTE GENERALI DEL DISEGNO :

P R

O S

P E

T T

I S U

A S

S E

E

A

N D

COLMO TOS

GRONDA TOS

LIV. PORTE

PRIMO PIANO

FOND.

MAGRONE

COLMO TOS

GRONDA TOS

LIV. PORTE

PRIMO PIANO

B1

SB201B

B1

SB202B

A1

SB202B

A1

SB201B

2 3 4

A

C

D

E

F

G

5 6 7 8 91

8500 7750 7750 7750 7750 7750 7750 8500

63500

SF102B

B1

SF103B

B1

SF104B

B1

SF105B

B1

SF401B

C1

B

KEY PLAN

PIANTA DI RIFERIMENTO

A B

C DNORD DELLA PIANTA

PLAN NORTH

5 0 5 10 15

1:200

1 : 200

OVERALL ROOF FRAMING PLAN

B1 CARPENTERIA GENERALE DELLA COPERTURA

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

1 : 200

/1

/2

:3

:3

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

O V

E R

A

LL

R O

O F

F R

A M

IN

G

P

LA

N

SF101B

PD AA ES

S F

1B

O V

E R

A

LL

R O

O F

F R

A M

IN

G

P

LA

N

14121679 265 429

1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001B AND

S002B.

PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO ALLE

TAVOLE S001B E S002B.

2. COORDINATE ROOF PENETRATIONS WITH ARCHITECTURAL DRAWINGS AND

DETAIL D3 ON SHEET SK556.

COORDINARE LE FOROMETRIE IN COPERTURA CON I GRAFICI ARCHITETTONICI E

IL PARTICOLARE D3 SUL DISEGNO SK556.

GENERAL SHEET NOTES:

NOTE GENERALI DEL DISEGNO :

C A

R P

E N

T E

R

IA

G E

N E

R A

L E

D E

L L

A C

O P

E R

T U

E

F

G

8500 7750 7750 7750

A1

SF301B

A1

SF301B

M A

T C

H

LI

N E

S

E E

B

O N

S H

E E

T S

F

3B

MATCHLINE - SEE B1 ON SHEET SF104B

D3

SK556

1 : 100SF101B

ROOF FRAMING - AREA A

B1 CARPENTERIA COPERTURA- AREA A

1 0 1 2 3 4 5 6 7 8 9

1:100

KEY PLAN

PIANTA DI RIFERIMENTO

A B

C D

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E D

I- R

A D

R S

T O

R A

G E

F A

C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

JTW

1 : 100

/1

/2

:3

:4

E

L a v o ri \2

\0

-R

A D

R A v ia n o \F in a l p e r fi rm e \B

L D

G C

R -1

-S

.r v t

R O

O F

F R

A M

IN

G

A

R E

A A

SF102B

PD AA ES

S F

2B

R O

O F

F R

A M

IN

G

A

R E

A A

14121680 266 429

NORD DELLA PIANTA

PLAN NORTH

KEY #

KEYED NOTES / NOTE CHIAVE

ENGLISH NOTE NOTA ITALIANA

1 COLUMN HEB320 COLONNA HEB320

2 BEAM IPE400 TRAVE IPE400

3 BEAM HEB220 TRAVE HEB220

4 ANGLE L 150x12 CONTROVENTO L 150x12

5 ANGLE L 100x10 CONTROVENTO L 100x10

1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001B AND

S002B.

PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO ALLE

TAVOLE S001B E S002B.

2. COORDINATE ROOF PENETRATIONS WITH ARCHITECTURAL DRAWINGS AND

DETAIL D3 ON SHEET SK556.

COORDINARE LE FOROMETRIE IN COPERTURA CON I GRAFICI ARCHITETTONICI E

IL PARTICOLARE D3 SUL DISEGNO SK556.

GENERAL SHEET NOTES:

NOTE GENERALI DEL DISEGNO :

C A

R P

E N

T E

R

IA

C O

P E

R T

U R

A

A R

E A

A

LINEA DI COLLEGAMENTO - VEDI B1

SU TAV. SF104B

LI

N

E A

D I C

O

LL

E G

A M

E N

T O

V

E D

I B

S U

T A

V . S

F

3B

F

G

5 6 7 8 9

7750 7750 7750 8500

B1

SF301B

B1

SF301B

MATCHLINE - SEE B1 ON SHEET SF105B

M A

T C

H

LIN

E

S E

E B

1 O N

S H

E E

T S

F 102B

SK557

C1

SK556

A1

SK556

C1

KEY PLAN

PIANTA DI RIFERIMENTO

A B

C D

1 : 100SF101B

ROOF FRAMING - AREA B

B1 CARPENTERIA COPERTURA - AREA B

DOTT. ING.

DI STEFANO PIETRO

ISCRITTO ALL'ALBO

PROFESSIONALE

COL N. 13921

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

T

V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .