Attachment H 1659896dwgVOL1_3of3.pdf

PDF 10 MB Posted

Attached to
P-002 EDI: Rapid Airfield Damage Recovery Storage Facilities, Aviano Air Base, Italy
Solicitation number
N6247022R3000
Issued by

About this file

This document provides details on a federal solicitation for construction services. The solicitation number is N6247022R3000 and is being issued by the Department of the Navy Naval Facilities Engineering Command for Rapid Airfield Damage Recovery Storage Facilities at Aviano Air Base in Italy. The solicitation seeks construction services to build new storage facilities that will support rapid repair of airfield infrastructure damaged during combat or natural disaster operations. Responses are due based on the standard FAR timeline and procedures for sealed bid construction contracts. The award date will be determined based on the receipt of responsive bids and completion of the standard evaluation process. The selected contractor will be responsible for providing all labor, materials, equipment and supervision to complete the storage facilities project at the Navy base in Italy.

View the file

Other files

File Type Posted
Amendment 0009.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007.pdf PDF
Attachment S - Revised Drawing CU101A.pdf PDF
Attachment O - Site Visit Sign In.pdf PDF
Attachment T - Revised Drawing CU101B.pdf PDF
Attachment R - Revised Drawing CS102B.pdf PDF
Attachment U - Revised Specification 01 50 00.pdf PDF
Amendment 0006.pdf PDF
Attachment P - Site 2 Access Road Aerial.pdf PDF
Attachment Q - Revised Drawing CD101A.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0003.pdf PDF
Attachment N - Gas Line Trench Detail.pdf PDF
Amendment 0002.pdf PDF
Attachment M - Installation Access Request Form.pdf PDF
Amendment 0001.pdf PDF
Attachment L - Installation Access Request Checklist.pdf PDF
Attachment E - Price Proposal Form.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
Attachment K - Italian Safety Plan_Combined.pdf PDF
Attachment H 1659896dwgVOL1_1of3.pdf PDF
Attachment H 1659896dwgVOL1_2of3.pdf PDF
Attachment C - Construction Experience Project Data Sheet.pdf PDF
Attachment G - Specifications.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment H 1659896dwgVOL2_1of4.pdf PDF
Attachment H 1659896dwgVOL2_3of4.pdf PDF
Attachment A - Pre-Proposal Inquiry Form.xls XLS spreadsheet
Attachment H 1659896dwgVOL2_2of4.pdf PDF
Attachment I - HAZMAT Report Summary.pdf PDF
Attachment J - Host Nation Code Compliance Certification.pdf PDF
N62470-22-R-3000.pdf PDF
Attachment H 1659896dwgVOL2_4of4.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ONE-LINE DIAGRAM SYMBOLS

SPD

MOLDED CASE CIRCUIT BREAKER

INTERRUTTORE DI CIRCUITO STAMPATO

MOLDED CASE CIRCUIT BREAKER:

INTERRUTTORE DI CIRCUITO STAMPATO:

S = SHUNT TRIP

BOBINA DI SGANCIO

SURGE PROTECTIVE DEVICE

DISPOSITIVO DI PROTEZIONE DA SOVRACCARICHI

GROUND

TERRA

METERING/MISURAZIONE:

CURRENT TRANSFORMER - SINGLE RATIO AS SHOWN

TRASFORMATORE DI CORRENTE - RAPPORTO SINGOLO COME INDICATO

PANELBOARD

SCHEDA DEL PANNELLO

PM

600/5

= POWER METER; CURRENT, VOLTAGE, FREQUENCY,

POWER FACTOR, (ACTIVE, REACTIVE, APPARENT POWER)

PM

= MISURATORE DI POTENZA; CORRENTE, TENSIONE,

FREQUENZA, FATTORE DI POTENZA, (POTENZA ATTIVA,

REATTIVA, APPARENTE)

DISCONNECT SWITCH

DISCONNETTERE INTERRURRORE

GENERAL NOTES

1. FOR SITE ELECTRICAL LEGEND, SEE SHEET GI020.

PER LA LEGENDA ELETTRICA DEL SITO, VEDERE LA SCHEDA GI020.

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O

F

H

E

A

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

NO SCALE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

/3

/2

:2 :3

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

E

LE

C T

R

IC

A L

LE

G

E N

D

S H

E E

T

E-001

BAW BAW JNG

E -0

E

LE

C

T R

IC

A

L

LE

G E

N D

S

H E

E T

14121562 148 429

LE

GE

ND

A

EL

ET

TR

IC

A

- T

AV

OL

DISCONNECT SWITCH, SIZE PER DRAWINGS. IP10 ENCLOSURE UNO

3P = NUMBER OF POLES, 60 = SWITCH RATING, NF = NON-FUSED

INTERRUTTORE DI SCOLLEGAMENTO TRIFASE, DIMENSIONI PER

DISEGNI. IP10 CUSTODIA UNO

3P = NUMERO DI POLI, 60 = GRADO DI INTERRUTTORE, NF = NON

FUSIBILE

GROUND CONDUCTOR

CONDUTTORE DI TERRA

GROUND ROD

ASTA DI TERRA

GROUND

TERRA

BRANCH CIRCUIT OR FEEDER WIRING IN CONDUIT. WIRING AND

CONDUIT SIZES SHOWN IN CABLE SCHEDULE AND PANEL

SCHEDULES.

CIRCUITO DI FILIALE O CABLAGGIO DI ALIMENTAZIONE IN CONDUIT.

DIMENSIONI DI CABLAGGIO E CONDOTTA INDICATE NELLA SCHEDA

DEI CAVI E NELLA SCHEDA DEI PANNELLI.

CONDUIT STUB WITH CAP

TRONCHETTO PER TUBI CON TAPPO

LIGHTNING PROTECTION CONDUCTOR

CONDUTTORE DI PROTEZIONE DA FULMINI

GROUND ROD INSPECTION TEST PIT

PIT DI PROVA DI ISPEZIONE ASTA DI TERRA

GROUND OR LIGHTNING PROTECTION CONDUCTOR

CONNECTION

COLLEGAMENTO DEL CONDUTTORE DI PROTEZIONE DA

TERRA O DA FULMINI

UNDERGROUND CONDUIT

CONDOTTO INTERRATO

LIGHTNING PROTECTION AIR TERMINAL

TERMINALE ARIA DI PROTEZIONE DA FULMINI

LIGHTING/ILLUMINAZIONEPOWER/POTENZAGROUNDING/MESSA A TERRA

RACEWAY/PISTA

METRIC SIZE CONVERSION

CONVERSIONE MISURA METRICA

USA TRADE

SIZE

COMMERCIO USA

TAGLIA

USA METRIC

TRADE SIZE

TAGLIA

COMMERCIALE

METRICA USA

1/2" 16mm

1" 27 mm

1-1/4" 35 mm

1-1/2" 41 mm

2" 53 mm

2-1/2" 63 mm

3" 78 mm

3-1/2" 91 mm

4" 103 mm

3/4" 21 mm

CONDUIT/CONDOTTO

5" 129 mm

6" 155 mm

LADDER TYPE CABLE TRAY. SEE PLANS AND DETAILS

FOR SIZES AND MOUNTING HEIGHTS.

PASSERELLA TIPO A SCALA. VEDI PIANTE E

DETTAGLI PER DIMENSIONI E ALTEZZE DI

MONTAGGIO.

SOLID BOTTOM/COVERED TYPE CABLE TRAY. SEE PLANS AND

DETAILS FOR SIZES AND MOUNTING HEIGHTS.

PASSERELLA PORTACAVI TIPO CON FONDO MASSICCIO/COPERTA.

VEDI PIANTE E DETTAGLI PER DIMENSIONI E ALTEZZE DI

MONTAGGIO.

INTERNATIONAL

METRIC TRADE SIZE

DIMENSIONE DEL

COMMERCIO METRICO

INTERNAZIONALE

15mm

25 mm

35 mm

40 mm

50 mm

65 mm

80 mm

90 mm

100 mm

20 mm

125 mm

150 mm

ELECTRICAL LIGHTING / POWER PANEL 400Y/230V

ILLUMINAZIONE ELETTRICA / QUADRO DI POTENZA 400Y/230V

IEC TYPE F DUPLEX RECEPTACLE MOUNTED AT 450mm, UNLESS

NOTED OTHERWISE.

PRESA DUPLEX DI TIPO F IEC MONTATA A 450 mm, SALVO

DISPOSIZIONE DIVERSA.

JUNCTION BOX, WALL MOUNTED

SCATOLA DI GIUNZIONE, MONTATA A PARETE

J

CIRCUIT LINE CONTINUATION TERMINATOR

TERMINATORE DI CONTINUAZIONE DELLA LINEA DEL CIRCUITO

*OPTIONS/OPZIONI:

WP= WEATHER PROOF/A PROVA DI INTEMPERIE

S = SHAVER SOCKET/PRESA PER RASOIO

DIGITAL SMART SWITCH 1200MM AFF

(FUNCTIONS VARY, SEE LIGHTING CONTROL DETAILS)

INTERRUTTORE INTELLIGENTE DIGITALE 1200MM AFF

(LE FUNZIONI VARIANO, VEDI DETTAGLI CONTROLLO

ILLUMINAZIONE)

LIGHTING POLE WITH ONE ARM/ ONE HEAD

X = FIXTURE TYPE, A3 = LIGHTING CIRCUIT 'A', THIRD LIGHT ON

CIRCUIT. SEE SITE LIGHTING PLANS

PALO DELL'ILLUMINAZIONE CON UN BRACCIO/UNA TESTA

X = TIPO DI APPARECCHIO, A3 = CIRCUITO DI ILLUMINAZIONE 'A',

TERZA LUCE SU CIRCUITO. VEDI PIANI ILLUMINANTI DEL SITO

WALL MOUNTED EXIT SIGN, SINGLE FACE

SEGNALE DI USCITA A PARETE, SINGOLA FACCIA

LED PENDANT/SURFACE MOUNT LINEAR

LED SOSPENSIONE/MONTAGGIO DA SUPERFICIE LINEARE

SQUARE LED DIRECT/INDIRECT RECESSED TROFFER.

TROFFER DA INCASSO A LED QUADRATO DIRETTO/INDIRETTO.

X

LED EXTERIOR, WALL MOUNTED LIGHT

ESTERNO A LED, LUCE A PARETE

* * : OC = OCCUPANCY SENSOR

SENSORE DI OCCUPAZIONE

DS = DAYLIGHT SENSOR

SENSORE DI LUCE DIURNA

HIGH BAY LED ROUND PENDANT MOUNTED

BAIA ALTA A LED TONDO A SOSPENSIONE MONTATA

DIAGONAL SHADED FIXTURE INDICATES EMERGENCY POWERED

FROM INTEGRAL BATTERY PACK (TYPICAL OF DIAGONALLY

SHADED FIXTURES).

L'APPARECCHIO DIAGONALE OMBREGGIATO INDICA EMERGENZA

ALIMENTATA DA PACCO BATTERIA INTEGRALE (TIPICO DEGLI

APPARECCHI DIAGONALMENTE OMBREGGIATI).

MISCELLANEOUS PANEL (SIZES VARY)

VARIE PANNELLO (DIMENSIONI VARIANO)

VFD: VARIABLE FREQUENCY DRIVE

HP RATING AS INDICATED. MOUNT AT 1200mm AFF

VFD: AZIONAMENTO A FREQUENZA VARIABILE

CLASSIFICAZIONE HP COME INDICATO. MONTAGGIO A 1200mm AFF

COMBINATION STARTER DISCONNECT, SIZE PER DRAWINGS. 230V

SINGLE PHASE, IP10 ENCLOSURE UNO

1P = NUMBER OF POLES, 60 = SWITCH RATING, 40 = TRIP RATING

COMBINAZIONE AVVIATORE SCOLLEGATO, DIMENSIONI PER DISEGNI.

230V MONOFASE, IP10 CUSTODIA UNO

1P = NUMERO DI POLI, 60 = GRADO DI INTERRUTTORE, 40 = GRADO DI

INTERRUZIONE

FIXTURE TAG IDENTIFICATION:

IDENTIFICAZIONE TAG DELL'APPARECCHIO:

FIXTURE TYPE TAG - SEE FIXTURE SCHEDULE

TAG DEL TIPO DI APPARECCHIO - VEDI SCHEDA

DELL'ATTREZZATURA

X =

LINE VOLTAGE TOGGLE LIGHT SWITCH 1200MM AFF

INTERRUTTORE LUCE A LEVA TENSIONE DI LINEA

1200MM AFF

PHOTOVOLTAIC/FOTOVOLTAICA

PHOTOVOLTAIC ARRAY

ARRAY FOTOVOLTAICO

CONCRETE ENCASED ELECTRODE

ELETTRODO INCASSATO IN CALCESTRUZZO

EXTERIOR PHOTOCELL

FOTOCELLULA ESTERNA

SWITCHING ZONES

ZONE DI COMMUTAZIONE

a,b,c,d =

S

GROUND BAR

BAR DA TERRA

3P 60

NF

1P

A3

X,b

HOMERUN TO PANEL. PANEL AND CIRCUIT DESIGNATIONS AS

INDICATED. TICK MARKS INDICATE NUMBER OF CONDUCTORS.

CHECK MARK " " INDICATES GROUND CONDUCTOR. FOR CABLE

SIZING SEE PANEL SCHEDULES.

HOMERUN AL PANNELLO. DESIGNAZIONI DEL PANNELLO E DEL

CIRCUITO COME INDICATO. I SEGNI INDICANO IL NUMERO DI

CONDUTTORI. SEGNO DI SPUNTA " " INDICA IL CONDUTTORE DI

TERRA. PER IL DIMENSIONAMENTO DEL CAVO VEDERE SCHEDE DEI

PANNELLI.

PB1-1,3,5

X

X

X

X

X

X

GENERAL NOTES/NOTE GENERALI

1. FOR SITE ELECTRICAL LEGEND, SEE SHEET GI020.

PER LA LEGENDA ELETTRICA DEL SITO, VEDERE LA SCHEDA GI020.

P

ELECTRICAL EQUIPMENT CONNECTION

COLLEGAMENTO APPARECCHI ELETTRICI

E

MOTOR CONNECTION, HP INDICATED

COLLEGAMENTO MOTORE, INDICATO HP

M

SINGLE PHASE SPECIAL PURPOSE RCPT OR CONNECTION.

MOUNTING AND TYPE AS NOTED ON PLANS.

MONOFASE PER USI SPECIALI RCPT O COLLEGAMENTO.

MONTAGGIO E TIPO COME RIPORTATO SUI PIANI.

GROUND CONDUCTOR CONNECTION TO LIGHTNING

PROTECTION CONDUCTOR

COLLEGAMENTO DEL CONDUTTORE DI TERRA AL

CONDUTTORE DI PROTEZIONE DA FULMINI

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

NO SCALE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

/3

/2

:2 :4

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

E

LE

C T

R

IC

A L

LE

G

E N

D

S H

E E

T

E-002

BAW BAW JNG

E -0

E

LE

C

T R

IC

A

L

LE

G E

N D

S

H E

E T

14121563 149 429

LE

GE

ND

A

EL

ET

TR

IC

A

- T

AV

OL

PIANTA IMPIANTO DI TERRA - GENERALE

P

IA

N T

A

IM

P

IA

N T

O D

I T E

R R

A

G E

N E

R A

LE

PER LE NOTE GENERALI IMPIANTO DI TERRA, VEDERE

TAVOLA EJ102A.

PIANTA DI RIFERIMENTO

NORD DELLA PIANTA

9876532

E

C

A

D

B

MECHANICAL

ELECTRICAL

JANITOR

RESTROOM

HEAVY REPAIR YARD

WAREHOUSE

COMM

104FIRE RISER

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 200

/3

/2

:2 :4

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

G R

O U

N D

IN

G

P

LA

N

O V

E R

A

LL

EJ101A

BAW BAW JNG

E J1

A

G R

O U

N D

IN

G

P

LA

N

O V

E R

A

LL

14121564 150 4291 0 1 2 3 4 5 6 7 8 9

1:100

PLAN NORTH

1 : 200 B2

GROUNDING PLAN - OVERALL

KEY PLAN

BA

NOTES:

1. FOR GENERAL GROUNDING NOTES, SEE SHEET EJ102A.

2. SEE SHEETS EJ102A AND EJ103A FOR GROUNDING AREA PLANS.

VEDERE LE SCHEDE EJ102A E EJ103A PER LE PIANTE DELLA

ZONA TERRA.

PIANTA IMPIANTO DI TERRA - AREA 'A'

IA

N T

A I M

P

IA

N T

O D

I T

E R

R A

A

R E

A

'A

PIANTA DI RIFERIMENTO

NORD DELLA PIANTA

PANNELLO MDP

E

C

A

D

B

M A

T C

H

LI

N E

S

E E

A

O N

S H

E E

T E

J1

A

PANEL MDP

120mm² BRAIDED BARE COPPER GROUND CONDUCTOR AT 762mm BELOW GRADE (TYP FOR EXTERIOR GROUNDING RING)

CONDUTTORE DI TERRA IN RAME NUDO INTRECCIATO DA

120 mm² A 762mm SOTTO TERRA (TIP PER ANELLO DI MESSA A

TERRA ESTERNO)

20mm X 3000mm GROUND ROD (TYP) PICCHETTO DI TERRA 20mm X 3000mm

(TIP)

70mm² BRAIDED BARE COPPER BONDING CONDUCTOR (TYP)

CONDUTTORE DI COLLEGAMENTO DI TERRA IN RAME NUDO

INTRECCIATO DA 70 mm² (TIP)

GROUND ROD INSPECTION TEST

PIT (TYP)

POZZETTO DI ISPEZIONE

PICCHETTO DI TERRA (TIP)

LI

N

E A

D I U

N

IO

N E

V

E D

I A

S U

L F

O G

LI

O

E J1

A

MGB

PBB

CONCRETE ENCASED ELECTRODE (TYP)

ELETTRODO INCASSATO IN CALCESTRUZZO (TIP)

EXOTHERMIC OR HIGH COMPRESSION

CONNECTION (TYP)

COLLEGAMENTO ESOTERMICO O AD ALTA

COMPRESSIONE (TIP)

SOLID BARE CLASS I MAIN LIGHTNING PROTECTION DOWN CONDUCTOR TO

LIGHTNING PROTECTION SYSTEM. FOR CONTINUATION SEE LIGHTNING

PROTECTION PLAN EJ110A (TYP).

SOLIDO NUDO CLASSE I IN PRINCIPALE CONDUTTORE DI PROTEZIONE DAI

FULMINI AL SISTEMA DI PROTEZIONE DAI FULMINI. PER IL CONTINUAZIONE

VEDERE IL PIANO DI PROTEZIONE DAI FULMINI EJ110A (TIP)

HP-01 HP-02

AHU-01

P-03

P-04 AHU-02

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 100

/3

/2

:2 :4

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

G R

O U

N D

IN

G

P

LA

N

A R

E A

'A

EJ102A

BAW BAW JNG

E J1

A

G R

O U

N D

IN

G

P

LA

N

A R

E A

'A

14121565 151 429

1 : 100 A3

GROUNDING PLAN - AREA 'A'

1 0 1 2 3 4 5 6 7 8 9

1:100

PLAN NORTH

KEY PLAN

BA

1. FOR ELECTRICAL LEGEND, SEE SHEETS E-001 AND E-002.

PER LA LEGENDA ELETTRICA, VEDERE TAVOLE E-001 ED E-002.

2. FOR LIGHTNING PROTECTION PLANS SEE SHEET EJ110A.

PER LE PIANTE DI PROTEZIONE CONTRO I JULMINI VEDERE LA TAVOLA

EJ110A.

3. GROUND METALLIC PIPING SUCH AS WATER, COMPRESSED AIR, FIRE

PIPING, ETC, PER NFPA AND ITALIAN CODE.

COLLEGARE A TERRA TUTTE LE TUBAZIONI METALLICHE COME ACQUA ARIA

COMPRESSA, ANTINCENDIO, ECC, PER NFPA E CODICE ITALIANO.

4. GROUND GRID MUST BE LOCATED 1500mm NOMINAL FROM THE OUTSIDE

EDGE OF THE BUILDING FOUNDATION.

LA GRIGLIA DI TERRA DEVE ESSERE COLLOCATA A 1500mm NOMINALI DAL

BORDO ESTERNO DELLA FONDAZIONE DELL'EDIFICIO.

5. SEE SHEET EK552 FOR TYPICAL GROUNDING DIAGRAM.

VEDERE LA SCHEDA EK552 PER IL TIPICO SCHEMA DI MESSA A TERRA.

NOTES:

PIANTA IMPIANTO DI TERRA - AREA 'B'

IA

N T

A

IM

P

IA

N T

O D

I T E

R R

A

A R

E A

B

PER LE NOTE GENERALI DELL' IMPIANTO DI TERRA,

VEDERE TAVOLA EJ102A.

LIN

E

A D

I U N

IO

N

E

- V

E D

I A 3 S

U L F

O G

LIO

E

J102A

PIANTA DI RIFERIMENTONORD DELLA PIANTA

98765

E

C

A

D

B

M A

T C

H

LIN

E

S E

E A

3 O N

S H

E E

T E

J102A

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 100

/3

/2

:2 :5

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

G R

O U

N D

IN

G

P

LA

N

A R

E A

'B

EJ103A

BAW BAW JNG

E J1

A

G R

O U

N D

IN

G

P

LA

N

A R

E A

'B

14121566 152 429

1 : 100 A3

GROUNDING PLAN - AREA 'B'

1 0 1 2 3 4 5 6 7 8 9

1:100

PLAN NORTH

KEY PLAN

BA

1. FOR GENERAL GROUNDING NOTES, SEE SHEET EJ102A.

IA

N T

A I M

P

IA

N T

O P

R O

T E

Z

IO

N E

D A

S C

A R

IC

H

E A

T M

O S

F E

R

IC

H E

G

E N

E R

A L E

NORD DELLA PIANTA

9876532

E

C

A

D

B

PV PANEL MOUNTING RAIL (TYP)

GUIDA DEL PANNELLO FV

SOLID BARE CLASS I ALUMINUM MAIN LIGHTNING

PROTECTION DOWN CONDUCTOR TO GROUND GRID (TYP)

SOLIDO NUDO CLASSE I IN ALLUMINIO PROTEZIONE

PRINCIPALE CONDUTTORE DI DISCESA A GRIGLIA DI TERRA

(TIP)

CLASS I SOLID ALUMINUM AIR TERMINAL 13mm X 610mm (TYP)

CLASSE I TERMINALE ARIA IN ALLUMINIO

MASSICCIO 13mm X 610mm (TIP)

SOLID BARE CLASS I ALUMINUM MAIN LIGHTNING

PROTECTION CONDUCTOR (TYP)

CONDUTTORE PRINCIPALE DI PROTEZIONE DA FULMINI

IN ALLUMINIO NUDO SOLIDO CLASSE I (TIP)

COORDINATE RIDGE CONDUCTOR AND AIR TERMINALS WITH FALL PROTECTION SYSTEM

SHOWN ON STRUCTURAL SHEETS SK568 AND SK569. BOND LIGHTNING PROTECTION SYSTEM

TO FALL PROTECTION SYSTEM. AIR TERMINAL SHALL EXTEND 300MM ABOVE FALL

PROTECTION SYSTEM (TYP)

CONDUTTORE DI COLMO COORDINATO E TERMINALI IN ARIA CON SISTEMA ANTICADUTA

RIPORTATI SULLE LAMIERE STRUTTURALI SK568 E SK569. SISTEMA DI PROTEZIONE DA

FULMINI BOND AL SISTEMA DI PROTEZIONE CADUTA. IL TERMINALE DELL'ARIA DEVE

ESTENDERE 300 MM SOPRA IL SISTEMA DI PROTEZIONE ANTICADUTA (TIP)

BOND LIGHTNING PROTECTION TO PV SYSTEM

MOUNTING RAILS. SEE NOTE 16.

PROTEZIONE DA FULMINE INCOLLAGGIO SU GUIDE DI

MONTAGGIO IMPIANTO FOTOVOLTAICO. VEDI NOTA 16.

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 200

/3

/2

:2 :0

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

LI

G

H T

N

IN

G P

R O

T E

C T

IO

N

P

LA

N

EJ110A

BAW BAW MZ

E J1

A

L

IG

H T

N

IN

G P

R O

T E

C T

IO

N

P

LA

N

14121567 153 429

1 : 200 A2

LIGHTNING PROTECTION PLAN

5 0 5 10 15

1:200

PLAN NORTH

KEY PLAN

BA

NOTES:

1. FOR ELECTRICAL LEGEND SEE SHEETS E-001 AND E-002.

PER LA LEGENDA ELETTRICA, VEDERE TAVOLE E-001 ED E-002

2. FOR GROUNDING PLANS SEE SHEETS EJ101A THRU EJ103A.

PER LE PIANTE DELL'IMPIANTO DI MESSA A TERRA, VEDERE LE TAVOLE DA EJ101A AD EJ103A.

3. THE SYSTEM(S) MUST INCLUDE ROOF-MOUNTED AIR TERMINALS, INTERCONNECTING CONDUCTORS, DOWN CONDUCTORS TO GROUND TERMINATIONS. COORDINATE

LIGHTNING PROTECTION SYSTEM WITH ROOFING MANUFACTURER.

I SISTEMI DEVONO COMPRENDERE TERMINALI ARIA MONTATI SUL TETTO, CONDUTTORI DI INTERCONNESSIONE, CONDUTTORI DI DISCESA A TERMINAZIONI DI TERRA. SISTEMA

COORDINATO DI PROTEZIONE DA FULMINI CON PRODUTTORE DI COPERTURE.

4. CONNECTION TO GROUND ROD OR GROUND LOOP CONDUCTOR MUST BE MADE IN GROUND ROD INSPECTION PIT. BOND METAL OBJECTS WITHIN 2000mm OF LP SYSTEM

(LOUVERS, WINDOWS, DOORS).

IL COLLEGAMENTO AL PICCHETTO DI TERRA O ALL'ANELLO DI TERRA DEVE ESSERE EFFETTUATO NEL POZZETTO DI ISPEZIONE. COLLEGARE TUTTI GLI OGGETTI IN METALLO

ENTRO 2000 mm DAL SISTEMA DI PROTEZIONE DA SCARICHE ATMOSFERICHE (GRIGLIE DI AREAZIONE, FINESTRE, PORTE).

5. AIR TERMINALS MUST BE PLACED AT ALL UNPROTECTED OUTSIDE CORNERS AND LOCATED INTERMEDIATELY ON 7600mm MAXIMUM SPACING AROUND THE ROOF PERIMETER

OR RIDGE AND WITHIN 600mm OF OUTSIDE EDGE.

LE ASTE DI CAPTAZIONE DEVONO ESSERE POSIZIONATE IN TUTTI GLI ANGOLI ESTERNI NON PROTETTI E SITUATI INTERDISTANZIATE DA 7600 mm MASSIMO INTORNO AL

PERIMETRO O COLMO DEL TETTO ED ENTRO 600 mm DAL BORDO ESTERNO.

6. PROVIDE MID ROOF AREAS WITH AIR TERMINALS SPACED EITHER AT 15000mm ON CENTER OR, OF SUFFICIENT QUANTITY AND HEIGHT, TO ENSURE THE ENTIRE ROOF AREA IS

COVERED BY A "ZONE-OF-PROTECTION" AS AFFORDED BY A 45 METER RADIUS SPHERE.

LE SUPERFICI DEL TETTO DEVONO ESSERE DOTATE DI ASTE DI CAPTAZIONE DISTANZIATE 15000 mm DAL CENTRO OPPURE, DI QUANTITÀ E DI ALTEZZA SUFFICIENTI, PER

GARANTIRE CHE L'INTERA AREA DEL TETTO SIA COPERTA DA UNA "ZONA DI PROTEZIONE" COME PERMESSA DA UNA SFERA DI RAGGIO DI 45 METRI.

7. GROUNDED METAL BODIES LOCATED ABOUT THE STRUCTURE SUCH AS: SOIL PIPE VENTS, ROOF DRAINS, EXHAUST FANS, AIR HANDLING UNITS, ANY MISCELLANEOUS

EQUIPMENT WITH ELECTRICAL SERVICES, ETC. MUST BE INTERCONNECTED TO THE LIGHTNING CONDUCTOR SYSTEM.

CORPI METALLICI CON MESSA A TERRA UBICATI INTORNO ALLA STRUTTURA QUALI: SCARICHI PER TUBI TERRA, SCARICHI A TETTO, VENTOLE DI SCARICO, UNITÀ DI TRATTAMENTO ARIA, EVENTUALI ATTREZZATURE VARIE CON SERVIZI ELETTRICI, ECC. DEVE ESSERE INTERCONNESSO AL SISTEMA CONDUTTORE FULMINI.

8. BOND METALLIC PIPES INCLUDING WATER, FIRE, GAS, SEWER, STORM, PHOTOVOLTAIC SYSTEM, ETC. WHICH ENTER THE STRUCTURE, WITHIN 3500mm OF GRADE, TO THE

NEAREST DOWN CONDUCTOR, GROUND ROD, OR GROUND LOOP.

COLLEGARE TUBI METALLICI COMPRESI ACQUA, INCENDIO, GAS, FOGNATURE, TEMPESTA, IMPIANTO FOTOVOLTAICO, ECC. CHE ENTRANO NELLA STRUTTURA, ENTRO 3500 mm DI GRADO, AL CONDUTTORE IN DISCESA, ALL'ASTA DI TERRA O ALL'ANELLO DI TERRA PIÙ VICINI.

9. NO BEND OF A CONDUCTOR MAY FORM A FINAL INCLUDED ANGLE OF LESS THAN 1.57 RAD NOR HAVE A RADIUS OF BEND OF LESS THAN 200mm.

NESSUNA CURVA DI UN CONDUTTORE DEVE FORMARE UN ANGOLO INFERIORE A 1,57 RAD NÉ AVERE UN RAGGIO DI CURVATURA INFERIORE A 200 mm.

10. CONDUCTORS MUST INTERCONNECT AIR TERMINALS AND MUST FORM A TWO-WAY PATH FROM EACH AIR TERMINAL HORIZONTALLY OR DOWNWARD TO CONNECTIONS WITH

GROUND TERMINALS.

I CONDUTTORI DEVONO INTERCONNETTERE I TERMINALI DELL'ARIA E DEVONO FORMARE UN PERCORSO A DUE VIE DA CIASCUN TERMINALE ORIZZONTALE O VERSO IL BASSO

AI COLLEGAMENTI CON I TERMINALI DI TERRA.

11. LIGHTNING PROTECTION CONDUCTORS MUST BE FASTENED NOT MORE THAN 900mm MAXIMUM SPACING.

TUTTI I CONDUTTORI DI PROTEZIONE DALLE SCARICHE ATMOSFERICHE DEVONO ESSERE FISSATI A NON PIU' DI 900 mm COME DISTANZA MASSIMA.

12. ACTUAL JOBSITE CONDITIONS MAY NECESSITATE SLIGHT ALTERATIONS IN AIR TERMINAL AND GROUND ROD LOCATIONS.

LE CONDIZIONI REALI DEL CANTIERE POTREBBERO NECESSITARE DI LEGGERE ALTERAZIONI DELLE UBICAZIONI DELLE ASTE DI CAPTAZIONE E DEI DISPERSORI DI TERRA

13. BARE COPPER LIGHTNING PROTECTION MATERIALS MUST NOT BE INSTALLED ON ALUMINUM ROOF OR SIDING OR OTHER ALUMINUM SURFACES AND VICE VERSA, ALUMINUM LIGHTNING PROTECTION MATERIALS MUST NOT BE INSTALLED ON COPPER ROOFING OR COPPER SIDING OR OTHER COPPER SURFACES.

I MATERIALI DI PROTEZIONE DALLE SCARICHE ATMOSFERICHE IN RAME NON DEVONO ESSERE INSTALLATI SU TETTI O RIVESTIMENTI IN ALLUMINIO O ALTRE SUPERFICI IN

ALLUMINIO E VICEVERSA, I MATERIALI DI PROTEZIONE DALLE SCARICHE ATMOSFERICHE IN ALLUMINIO NON DEVONO ESSERE INSTALLATI SU COPERTURE IN RAME O

RIVESTIMENTI IN RAME O ALTRE SUPERFICI IN RAME.

14. SEAL ENDS OF CONDUIT MOISTURE TIGHT WITH DUCT SEAL OR LEAD WEDGE. CONDUIT, CONDUIT FASTENERS, AND MISCELLANEOUS ACCESSORIES MUST BE FURNISHED

AND INSTALLED BY THE ELECTRICAL CONTRACTOR.

SIGILLARE LE ESTREMITÀ DEI TUBI A PROVA DI UMIDITÀ CON GUARNIZIONI O CON PIOMBO. TUTTI I TUBI, FISSAGGI E ACCESSORI VARI DEVONO ESSERE FORNITI E INSTALLATI

DALL'APPALTATORE ELETTRICO.

15. USE A BI-METALLIC CONNECTOR AND TEST JOINT AT 600mm ABOVE GRADE TO TRANSITION ALUMINUM DOWN CONDUCTOR TO COPPER GROUND GRID SYSTEM.

UTILIZZARE UN CONNETTORE BIMETALLICO E UN GIUNTO DI PROVA A 600 mm FUORI TERRA PER CONGIUNGERE LE CALATE IN ALLUMINIO AL SISTEMA DI TERRA IN RAME.

16. BOND EACH STRING OF THE PHOTOVOLTAIC SYSTEM TO THE LIGHTNING PROTECTION SYSTEM.

COLLEGARE OGNI CORDA DELL'IMPIANTO FOTOVOLTAICO ALL'IMPIANTO DI PROTEZIONE DALLE SCARICHE ATMOSFERICHE

17. AIR TERMINAL MUST EXTEND A MINIMUM OF 254mm VERTICALLY ABOVE THE APEX OF THE SOLAR PANEL.

L'AEROSTAZIONE DEVE ESTENDERSI PER UN MINIMO DI 254 mm VERTICALMENTE SOPRA L'APICE DEL PANNELLO SOLARE.

PIANTA IMPIANTO PROTEZIONE DA SCARICHE ATMOSFERICHE

PIANTA DI RIFERIMENTO

N T

A I M

P

IA

N T

O D

I

IL

L U

M

IN

A Z

IO

N

E G

E N

E R

A L E

PIANTA IMPIANTO DI ILLUMINAZIONE - GENERALE

NOTE:

PIANTA DI RIFERIMENTONORD DELLA PIANTA

9876532

E

C

A

D

B

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 200

/3

/2

:2 :0

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

LI

G

H T

IN

G

P

LA

N

O V

E R

A

LL

EL101A

JMD JMD JNG

E L1

A

L

IG

H T

IN

G

P

LA

N

O V

E R

A

LL

14121568 154 429

1 : 200 B3

LIGHTING PLAN - OVERALL

5 0 5 10 15

1:200

PLAN NORTH

KEY PLAN

BA

NOTES:

1. FOR GENERAL LIGHTING NOTES, SEE SHEET EL102A.

PER NOTE DI ILLUMINAZIONE GENERALE, VEDERE LA SCHEDA

EL102A.

2. SEE SHEETS EL102A AND EL103A FOR LIGHTING AREA PLANS.

VEDERE LE SCHEDE EL102A ED EL103A PER LE PLANIMETRIE

DELLA ZONA ILLUMINAZIONE.

N T

A I M

P

IA

N T

O D

I

IL

L U

M

IN

A Z

IO

N

E

A R

E A

A

PIANTA IMPIANTO DI ILLUMINAZIONE - AREA "A"

NOTE:

PER LA LEGENDA ELETTRICA VEDI TAVOLE E-001 E E-002

COLLEGARE LA SEGNALETICA DI USCITA AL RAMO NON

COMMUTATO PRIMA DEL CONTROLLO DELL'ILLUMINAZIONE

ALL'AREA

PIANTA DI RIFERIMENTO

NORD DELLA PIANTA

L

IN

E A

D I U

N

IO

N E

V

E D

I A

S

U L F

O G

L

IO

E L A

S S

S S

OC

OC

DS

J

E

C

A

D

B

M A

T C

H

LI

N E

S

E E

A

O N

S H

E E

T E

L1

A

EL401A

B2

EL401A

B3

LP1- 2

LP1- 7

Aa

Aa

Ab

Ab Aa

Aa Ab

Ab

AaAb Ab

Aa

Aa

Aa

AbAaAa

Aa Ab Aa Ab Aa

AaAb

X W

W

W

W

W

X

MECHANICAL

ELECTRICAL

COMM

RESTROOM

FIRE RISER

JANITOR

HEAVY REPAIR YARD

WAREHOUSE

W W W W

W W W WLP1- 12

LP1

MOUNT TO

JUNCTION BOX

AT 5000mm AFF

MONTAGGIO A

SCATOLA DI

GIUNZIONE A

5000mm SOPRA

IL PIANO FINITO

a,b

LCP-1

P

LC-1

LP1- 6

W

HP-01 HP-02

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 100

/3

/2

:2 :1

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

LI

G

H T

IN

G

P

LA

N

A R

E A

'A

EL102A

JMD JMD JNG

E L1

A

L

IG

H T

IN

G

P

LA

N

A R

E A

'A

14121569 155 429

1 : 100 A3

LIGHTING PLAN - AREA 'A'

1 0 1 2 3 4 5 6 7 8 9

1:100

PLAN NORTH

KEY PLAN

BA

NOTES:

1. FOR ELECTRICAL LEGEND, SEE SHEETS E-001 AND E-002

2. CONNECT EXIT SIGNS TO NON-SWITCHED LEG AHEAD OF

LIGHTING CONTROL TO THE AREA

3. FOR LIGHT FIXTURE SCHEDULE SEE SHEET EK651.

PER LA TABELLA APPARECCHI ILLUMINANTI EK651.

4. FOR ELECTRICAL LIGHTING AND CONTROLS DETAILS SEE

EK570 SERIES SHEETS.

PER I DETTAGLI DI ILLUMINAZIONE E COMANDI ELETTRICI

VEDERE LE SCHEDE SERIE EK570.

5. FOR PANEL SCHEDULES SEE EP600 SERIES SHEETS.

PER LE GLI SCHEMI DEI QUADRI VEDERE LE TAVOLE VEDERE

LE SERIE EP600.

6. FOR EXTERIOR WALL PACK TYPE 'W' AND EXIT SIGN TYPE 'X',

MOUNT 150mm ABOVE DOOR FRAME, TYP.

PER PACCHETTO DA PARETE ESTERNO TIPO 'W' E SEGNALE

DI USCITA TIPO 'X', MONTAGGIO 150mm SOPRA IL TELAIO

DELLA PORTA, TIPICO.

7. FOR ROOMS WITHOUT CEILINGS, TYPE B1/B2 RIGID PENDANT

MOUNT AT 3000mm AFF TO BOTTOM OF FIXTURE.

PER LOCALI SENZA SOFFITTO, ATTACCO A SOSPENSIONE

RIGIDO TIPO B1/B2 A 3000mm SOPRA IL PAVIMENTO FINITO

DAL FONTO DELL'APPARECCHIO.

8. TYPE 'A' HIGH BAY LIGHTS MOUNT AT 5000mm TO BOTTOM OF

FIXTURE, TYP.

MONTAGGIO LUCI A BAIA ALTA TIPO 'A' A 5000mm FINO AL

FONDO DELL'APPARECCHIO, TIPICO

9. FOR SITE LIGHTING SEE SHEET ES102A. SEE ENLARGED

PLANS ON EP400 SERIES SHEETS FOR ROUTE.

PER L'ILLUMINAZIONE DEL CANTIERE VEDERE LA SCHEDA

ES102A. VEDI PIANI INGRANDITI SULLE LASTRE SERIE EP400

PER PERCORSO.

10. FOR LIGHTING CONTROLS IN ROOM 100 SEE DETAIL B1 ON

SHEET EK575. FOR LIGHTING CONTROLS IN ROOMS 101 AND

102 SEE DETAIL B3 ON SHEET EK575.

PER I COMANDI DELL'ILLUMINAZIONE NELLA LOCALE 100

VEDERE IL DETTAGLIO B1 DELLA SCHEDA EK575. PER I

COMANDI DELL'ILLUMINAZIONE NEI LOCALI 101 E 102 VEDERE

IL DETTAGLIO B3 DELLA SCHEDA EK575.

CENTER EXIT SIGN ON

DOORWAY, SHOWN

OFFSET FOR SYMBOL

CLARITY

CARTELLO USCITA

CENTRO SULLA PORTA,

MOSTRATO OFFSET PER

CHIAREZZA SIMBOLO

N T

A I M

P

IA

N T

O D

I

IL

L U

M

IN

A Z

IO

N

E

A R

E A

B

NOTE:

PER LE NOTE GENERALI DELL'IMPIANTO DI ILLUMINAZIONE

VEDERE TAVOLA EL102A

PIANTA IMPIANTO DI ILLUMINAZIONE - AREA "B"

L

IN

E A

D I U

N

IO

N E

- V E

D I A

S

U L F

O G

L

IO

E L A

PIANTA DI RIFERIMENTO

NORD DELLA PIANTA

S S

DS

98765

E

C

A

D

B

M A

T C

H

LIN

E

S E

E A

3 O N

S H

E E

T E

L102A

LP1- 5

LP1- 4

Ac

Ac

Ac

Ac

Ac

Ad

Ad

Ad

Ad Ac Ad

AdAc

Ac Ad

AdAc

Ad Ac Ad

Ac

Ac

Ac

Ac

Ac X

W

W X

HEAVY REPAIR YARD

WAREHOUSE

W W W W

W W W WLP1- 12

LP1- 6

MOUNT TO

JUNCTION BOX

AT 5000mm AFF

MONTAGGIO A

SCATOLA DI

GIUNZIONE A

5000mm SOPRA

IL PIANO FINITO

c,d W

MOUNT THIS LIGHT

AT 4500mm ABOVE

GRADE

MONTARE QUESTA

LUCE A 4500mm

SOPRA PAVIMENTO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 100

/3

/2

:2 :1

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

LI

G

H T

IN

G

P

LA

N

A R

E A

'B

EL103A

JMD JMD JNG

E L1

A

L

IG

H T

IN

G

P

LA

N

A R

E A

'B

14121570 156 429

1 : 100 A3

LIGHTING PLAN - AREA 'B'

1 0 1 2 3 4 5 6 7 8 9

1:100

PLAN NORTH

KEY PLAN

BA

1. FOR GENERAL LIGHTING NOTES, SEE SHEET EL102A.

PIANTA INGRANDITA-1 IMPIANTO DI ILLUMINAZIONE

IA

N T

E I N

G R

A N

D

IT

E I M

P

IA

N T

O D

I

IL

L U

M

IN

A Z

IO

N

E

PIANTA INGRANDITA-2 IMPIANTO DI ILLUMINAZIONE

J

S S

OC

OC

C

MECHANICAL

ELECTRICAL

LP1- 11

B1 B1 B1

B1 B1

B1

RP1LP1PP2PP1MDP LCP-1

LP1- 9

LC-1

X

X

600mm X 600mm X 200mm JUNCTION BOX

(USE FOR SITE LIGHTING CIRCUIT. SEE NOTE 2).

SCATOLA DI GIUNZIONE 600 mm X 600 mm X 200 mm (UTILIZZARE PER IL CIRCUITO DI

ILLUMINAZIONE DEL SITO. VEDERE NOTA 2).

FIRE RISER

COMM

RESTROOM

JANITOR

LP1- 1

B1

B1

B2

B2

B2

B2

B1C

RP2

X

X

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 50

/3

/2

:2 :2

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

E N

LA

R

G E

D L

IG

H

T

IN

G P

LA

N

S

EL401A

JMD JMD JNG

E L4

A

E N

LA

R

G E

D L

IG

H

T

IN

G P

LA

N

S

14121571 157 429

1. FOR GENERAL LIGHTING NOTES, SEE SHEET EL102A.

PER NOTE DI ILLUMINAZIONE GENERALE, VEDERE LA

SCHEDA EL102A.

2. FOR SITE LIGHTING, FIELD ROUTE CIRCUIT TO JUNCTION

BOX IN ELECTRICAL ROOM 105 AND UTILIZE 1-100mm

CONDUIT DUCT BANK OUT TO SITE. FOR CONTINUATION

SEE SHEET EP401A AND ES102A.

PER L'ILLUMINAZIONE DEL SITO, UTILIZZARE IL CIRCUITO

DEL PERCORSO SUL CAMPO ALLA SCATOLA DI GIUNZIONE

NELLA LOCALE ELETTRICA 105 E UTILIZZARE LA

CONDOTTA DA 1-100 mm IN BANCO SUL POSTO. PER IL

CONTINUAZIONE VEDERE LA SCHEDA EP401A E ES102A.

3. LIGHT FIXTURE LOCATIONS SHOWN IN PLANS HAVE BEEN

COORDINATED WITH OVERHEAD DUCTWORK, PIPING AND

MECHANICAL EQUIPMENT. COORDINATE IN FIELD FOR

BEST LIGHT COVERAGE IF CONDITIONS DIFFER.

LE POSIZIONI DEGLI IMPIANTI DI LUCE RIPORTATE NELLE

PIANTE SONO COORDINATE CON LE CONDOTTE AEREE, LE

TUBAZIONI E LE ATTREZZATURE MECCANICHE.

COORDINARE IN CAMPO PER LA MIGLIORE COPERTURA

DELLA LUCE IN CASO DI CONDIZIONI DIVERSE.

NOTES:

1 : 50 B2

ENLARGED LIGHTING PLAN -1

1 : 50 B3

ENLARGED LIGHTING PLAN - 2

43211

1:50

PLAN NORTH

NORD DELLA PIANTA

PIANTA IMPIANTO DI FORZA MOTRICE - GENERALE

IA

N T

A I M

P

IA

N T

O D

I F

O R

Z A

M O

T R

IC

E

G

E N

E R

A L E

PIANTA DI RIFERIMENTONORD DELLA PIANTA

S

W P

W P

W P

W P

W P

W P

N

NB

N P

J

9876532

E

C

A

D

B

HEAVY REPAIR YARD

WAREHOUSE

ELECTRICAL

COMM

RESTROOM

101JANITOR

FIRE RISER

MECHANICAL

A1

EP101A

ECA DB

GROUND FLOOR

TOS EAVE

600mm X 600mm X 200mm JUNCTION BOX FOR PENETRATION

INTO ELECTRICAL ROOM

SCATOLA DI GIUNZIONE 600mm X 600mm X 200mm PER LA

PENETRAZIONE NEL LOCALE ELETTRICO

2-25mm CONDUIT FROM SOLAR SYSTEM ON ROOF. FOR

CONTINUATION SEE SHEET EP110A

CONDOTTO 2-25mm DA IMPIANTO SOLARE SUL TETTO. PER IL

CONTINUAZIONE VEDERE LA SCHEDA EP110A

STAINLESS STEEL STRUCTURAL

CONDUIT SUPPORT AS REQUIRED (TYP)

STRUTTURA IN ACCIAIO INOX

SUPPORTO CONDOTTO COME RICHIESTO (TIP)

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 200

/3

/2

:2 :2

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

P O

W E

R P

LA

N

O

V E

R A

LL

EP101A

BAW BAW JNG

E P

1A

P O

W E

R P

LA

N

O

V E

R A

LL

14121572 158 429

1 : 200 B3

POWER PLAN - OVERALL

5 0 5 10 15

1:200

PLAN NORTH

KEY PLAN

BA

1. FOR GENERAL POWER PLAN NOTES SEE SHEET EP102A.

PER NOTE GENERALI SUL PIANO ELETTRICO VEDERE LA

SCHEDA EP102A.

2. SEE SHEETS EP102A THRU EP103A FOR POWER AREA

PLANS.

VEDERE LE SCHEDE DA EP102A A EP103A PER PIANI AREA

ELETTRICA.

NOTES:

1 : 200EP101A

A1

SOLAR SYSTEM CONDUIT ROUTING ELEVATION

ELEVAZIONE DEL PERCORSO DEL CONDOTTO DELL'IMPIANTO SOLARE

PIANTA IMPIANTO DI FORZA MOTRICE - AREA 'A'

IA

N T

A I M

P

IA

N T

O D

I F

O R

Z A

M O

T R

IC

E

A

R E

A 'A

PIANTA DI RIFERIMENTO

NORD DELLA PIANTA

L

IN

E A

D I U

N

IO

N E

V

E D

I A

S

U L F

O G

L

IO

E P

A

S

W P

W P

W P

W P

J

E

C

A

D

B

EP401A

B1

EP401A

B4

M A

T C

H

LI

N E

S

E E

A

O N

S H

E E

T E

P

3A

RP1- 13RP1- 11RP1- 12

RP1- 7

RP1- 1

RP1- 20 RP1- 19 RP1- 22 RP1- 21

CU-105

CU-104

HEAVY REPAIR YARD

WAREHOUSE

FIRE RISER

JANITOR

RESTROOM

COMM

ELECTRICAL

MECHANICAL

SF-02

SF-01

P-02

P-01

UH-01

UH-04

OH DOOR -100R

UH-05

OH DOOR - 100TOH DOOR - 100U OH DOOR - 100S

OH DOOR - 100B OH DOOR - 100C OH DOOR - 100D OH DOOR - 100E

MDP

PP1

PP2

LP1

RP1RP1- 31

RP1- 14

PP1- 13,15,17

PP1- 2,4,6

PP1- 1,3,5

RP1- 5

PP1- 14,16,18

PP2- 23

PP2- 2

PP2- 8

RP2

RP1- 4

RP1- 9

RP1- 2

RP1- 3

HP-01 HP-02 MDP- 2,4,6

MDP- 1,3,5

FOR CONTINUTION

SEE DRAWING ES101A

LCP-1

LC-1

PP2- 4

UH-02RP1- 31

VFD-SF01

VFD-P02

VFD-P01

VFD-SF02

E E

M M

M 1.5

M 1.5

E E

EE

1P30A

NF

M 0.5 M 0.5 M 0.5 M 0.5

M 0.5 M 0.5 M 0.5 M 0.5

1P30A

NF

1P30A

NF

1P30A

NF

1P30A

NF

1P30A

NF

1P30A

NF

1P30A

NF

3P 200A

NF

EWC-1

SEE NOTE 8

VEDI NOTA 8

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 100

/3

/2

:2 :3

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

P O

W E

R P

LA

N

A

R E

A 'A

EP102A

BAW BAW JNG

E P

2A

P O

W E

R P

LA

N

A

R E

A 'A

14121573 159 429

1 : 100 A3

POWER PLAN - AREA 'A'

1 0 1 2 3 4 5 6 7 8 9

1:100

PLAN NORTH

KEY PLAN

BA

1. FOR ELECTRICAL LEGEND, SEE SHEETS E-001 AND E-002.

PER LA LEGENDA ELETTRICA, VEDERE LE SCHEDE E-001 E

E-002

2. FOR ELECTRICAL DETAILS SEE EK550 SERIES SHEETS.

PER I DETTAGLI ELETTRICI VEDERE LE SCHEDE SERIE EK550.

3. FOR ONE LINE DIAGRAM, CABLE SCHEDULES, AND PANEL

SCHEDULES SEE EP600 SERIES SHEETS.

PER SCHEMI A UNA RIGA, SCHEDE DEI CAVI E SCHEDE DEI

PANNELLI, VEDERE LE FOGLIE DELLA SERIE EP600.

4. VARIABLE FREQUENCY DRIVE (VFD) RATINGS MUST BE

CONFIRMED WITH EQUIPMENT PROVIDED.

I VALORI DI AZIONAMENTO A FREQUENZA VARIABILE (VFD)

DEVONO ESSERE CONFERMATI CON L'ATTREZZATURA

FORNITA.

5. FOR OVERHEAD DOOR POWER REQUIREMENTS SEE DETAIL

A4 ON SHEET EK557.

PER I REQUISITI DI POTENZA DELLA PORTA BASCULANTE

VEDERE IL DETTAGLIO A4 DELLA SCHEDA EK557.

6. UNIT HEATER DISCONNECTS NOT SHOWN AS THEY ARE UNIT

MOUNTED FROM MANUFACTURER. COORDINATE WITH

MECHANICAL SCHEDULES ON SHEET MH602A.

IL RISCALDATORE SI DISCOLLEGA NON MOSTRATO IN QUANTO

SONO MONTATI SULL'UNITÀ DAL PRODUTTORE. COORDINARE

CON SCHEDE MECCANICHE SU SCHEDA MH602A.

7. CONDUIT AND CABLING FROM LOCAL DISCONNECT, STARTER,

OR VFD TO FINAL POWERED EQUIPMENT MUST BE SAME SIZE

AS BRANCH CIRCUIT CONDUIT AND CABLING SHOWN IN PANEL

SCHEDULES AND/OR CABLE SCHEDULES.

IL CONDOTTO E IL CABLAGGIO DAL DISCONNECT LOCALE,

D'AVVIAMENTO O VFD ALL'APPARECCHIATURA ALIMENTATA

FINALE DEVONO ESSERE DELLA STESSA DIMENSIONE DEL

CONDOTTO E DEL CABLAGGIO DEL CIRCUITO DI DIRAMAZIONE

MOSTRATI NEGLI SCHEMI DEI PANNELLI E/O DEI CAVI.

8. COORDINATE RECEPTACLE LOCATION WITH DRINKING

FOUNTAIN EWC-1.

POSIZIONE COORDINATA DEL RECIPIENTE CON FONTANA

POTABILE EWC-1.

PIANTA IMPIANTO DI FORZA MOTRICE - AREA 'B'

IA

N T

A I M

P

IA

N T

O D

I F

O R

Z A

M O

T R

IC

E

A

R E

A 'B

PIANTA DI RIFERIMENTO

NORD DELLA PIANTA

L

IN

E A

D I U

N

IO

N E

- V E

D I A

S

U L F

O G

L

IO

E P

A

W P

W P

98765

E

C

A

D

B

M A

T C

H

LIN

E

S E

E A

3 O N

S H

E E

T E

P 102A

RP1- 24 RP1- 23 RP1- 25

RP1- 17RP1- 18RP1- 15

RP1- 16

OH DOOR - 100MOH DOOR - 100NOH DOOR - 100POH DOOR - 100Q

OH DOOR - 100F OH DOOR - 100G OH DOOR - 100H OH DOOR - 100J

PP1- 26,28,30

PP1- 25,27,29

PP1- 20,22,24

PP1- 19,21,23

UH-05 UH-06

UH-03UH-02

RP1- 26

PP2- 8 PP2- 17

PP2- 6PP2- 4

RP1- 6

RP1- 4

RP1- 4

RP1- 2

RP1- 3

RP1- 1

RP1- 9

PP2- 4

UH-02

EF-04

EF-03

EF-02

EF-01

VFD-EF04

VFD-EF03

VFD-EF02

VFD-EF01

E E

EE

M 1.5

M 1.5

M 1.5

M 1.5

M 0.5 M 0.5 M 0.5 M 0.5

M 0.5 M 0.5 M 0.5 M 0.5

1P30A

NF

1P30A

NF

1P30A

NF

1P30A

NF

1P30A

NF

1P30A

NF

1P30A

NF

1P30A

NF

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 100

/3

/2

:2 :3

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

P O

W E

R P

LA

N

A

R E

A 'B

EP103A

BAW BAW JNG

E P

3A

P O

W E

R P

LA

N

A

R E

A 'B

14121574 160 429

1 : 100 A3

POWER PLAN - AREA 'B'

1 0 1 2 3 4 5 6 7 8 9

1:100

PLAN NORTH

KEY PLAN

BA

1. FOR GENERAL POWER PLAN NOTES SEE SHEET EP102A.

PER NOTE GENERALI SUL PIANO ELETTRICO VEDERE LA

SCHEDA EP102A.

PIANTA TETTO IMPIANTO DI FORZA MOTRICE

IA

N T

A T

E T

T O

I M

P

IA

N T

O D

I F

O R

Z A

M O

T R

IC

E

PIANTA DI RIFERIMENTO

NORD DELLA PIANTA

9876532

E

C

A

D

B

STRING 1 STRING 2 STRING 3 STRING 4 STRING 5 STRING 6 STRING 7 STRING 8 STRING 9 STRING 10

5970 22757

22757

LOCATION OF FIRST FLOOR ELECTRICAL ROOM

UBICAZIONE LOCALE ELETTRICO PRIMO PIANO

ROOF ACCESS HATCH

BOCCOLA DI ACCESSO AL TETTO

SKYLIGHT (TYP)

LUCERNARIO (TIP)

600mm X 600mm NEMA 3R STAINLESS STEEL DC COMBINER BOX (TYP) SCATOLA COMBINATORE NEMA 3R DC 600 mm X 600 mm (TIP)

25mm EMT CONDUIT TO DC COMBINER BOX IN FIRST FLOOR ELECTRIC ROOM (TYP) CONDOTTO ENT DA 25mm A BOX COMBINATORE DC IN CAMERA ELETTRICA PRIMO PIANO (TIP)

8120 7155

0 3

DIMENSIONS IN MILLIMETERS (mm) TYP THIS SHEET DIMENSIONI IN MILLIMETRI (mm) TIPICHE QUESTO FOGLIO

A1

EP101A

FOR CONDUIT

CONTINUATION SEE

DETAIL A1 EP101A

PER LA

CONTINUAZIONE

CONDOTTA VEDERE

DETTAGLIO A1 EP101A

SOLAR PANEL MOUNTING CLAMP

MORSETTO DI MONTAGGIO

PANNELLO SOLARE

STANDING SEAM METAL ROOF CONNECTOR

WITH CONNECTION FITTING ATTACHED

CONNETTORE PER TETTO IN METALLO CON

AGGRAFFATURA VERTICALE CON RACCORDO

DI COLLEGAMENTO ATTACCATO

PV SYSTEM MOUNTING RAIL

GUIDA DI MONTAGGIO DEL

SISTEMA FOTOVOLTAICO

STANDING SEAM ROOF

TETTO CON CUCITURE IN PIEDI

PV SYSTEM MOUNTING RAIL

TETTO CON CUCITURE IN PIEDI

PV PANEL

TETTO CON CUCITURE IN PIEDI

STANDING SEAM METAL ROOF CLAMP

MORSETTO DA TETTO IN METALLO AGGRAFFATO

STANDING SEAM METAL ROOF

TETTO IN METALLO AGGRAFFATO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

As indicated

/3

/2

:2 :3

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

R O

O F

P O

W E

R P

LA

N

EP110A

BAW BAW JNG

E P

0A

R O

O F

P O

W E

R P

LA

N

14121575 161 429

1 : 200 B3

ROOF POWER PLAN

5 0 5 10 15

1:200

PLAN NORTH

KEY PLAN

BA

1. FOR ELECTRICAL LEGEND, SEE SHEETS E-001 AND E-002.

PER LA LEGENDA ELETTRICA, VEDERE LE TAVOLE E-001 ED E-002.

2. EACH PV ARRAY CONSISTS OF 12 - 400W MODULES FOR 4.8 KW DC.

OGNI ARRAY FV È COMPOSTO DA 12 - MODULI 400W PER 4,8 KW DC.

3. ITALIAN D.M. 28/2011 CALCULATION REQUIRES A 48kW DC

PHOTOVOLTAIC SYSTEM.

IL D.M. 28/2011 RICHIEDE UN IMPIANTO FOTOVOLTAICO DA 48kW DC.

4. ALL STRING HOMERUNS MUST BE LABELED ON BOTH ENDS OF THE

CONNECTION WITH WITH STRING NUMBER AND, INVERTER NUMBER

AND POLARITY.

TUTTI GLI HOMERUN DI STRINGA DEVONO ESSERE ETICHETTATI SU

ENTRAMBE LE ESTREMITÀ DELLA CONNESSIONE CON IL NUMERO DI

STRINGA E, IL NUMERO DI INVERTER E LA POLARITÀ.

5. PV CONNECTORS UTILIZED FOR HOMERUN AND/OR CABLE WHIPS

MUST BE THE SAME MAKE AND MODEL AS THE MODULE PV

CONNECTORS.

I CONNETTORI FV UTILIZZATI PER HOMERUN E/O WHIP PER CAVI

DEVONO ESSERE DELLA STESSA MARCA E MODELLO DEI CONNETTORI

FV DEL MODULO.

6. PV WIRE MUST BE PROTECTED FROM SHARP EDGES USING TRIM LOCK

AND UV RESISTANT SPLIT LOOM.

IL FILO FV DEVE ESSERE PROTETTO DA BORDI AFFILATI UTILIZZANDO

TRIM LOCK E TELAIO SPLIT RESISTENTE AI UV.

7. ALL ASSOCIATED SPLIT LOOMS, ZIP TIES, CONNECTORS AND

BRACKETS MUST BE UV RATED.

TUTTI I TELAI DIVISI, LE FASCE ZIP, I CONNETTORI E LE STAFFE

ASSOCIATI DEVONO ESSERE CLASSIFICATI AI RAGGI UV.

8. PV CABLE MUST BE RPVU90 2KV RATED.

IL CAVO FV DEVE ESSERE RPVU90 2KV NOMINALE .

9. ALL MODULE TO MODULE AND MODULE TO HOMERUN CONNECTORS

MUST BE MATED TO PAIRS OF THE SAME MAKE AND MODEL.

TUTTI I CONNETTORI DA MODULO A MODULO E DA MODULO A

HOMERUN DEVONO ESSERE ACCOPPIATI A COPPIE DELLA STESSA

MARCA E MODELLO.

10. ROWS MUST BE SPACED WITH 2 METERS OF SEPERATION FOR

REGULAR MAINTENANCE.

LE FILE DEVONO ESSERE DISTANZIATE DI 2 METRI DI SEPARAZIONE

PER LA REGOLARE MANUTENZIONE.

11. PV SYSTEM DC CIRCUITS MUST NOT OCCUPY THE SAME EQUIPMENT

ENCLOSURE, RACEWAY, OR CONDUIT WITH OTHER NON-PV SYSTEMS

INCLUDING THE INVERTER OUTPUTS.

I CIRCUITI CC DELL'IMPIANTO FV NON DEVONO OCCUPARE LA STESSA

INVOLUCRO DELL'APPARECCHIATURA, CANALE O CONDOTTA CON

ALTRI SISTEMI NON FV COMPRESE LE USCITE DELL'INVERTER.

12. PV SYSTEM DC CIRCUIT CONDUCTORS MUST BE IDENTIFIED AT ALL

TERMINATION, CONNECTION, AND SPLICE POINTS BY TAGGING ALL

CONDUCTORS. INCLUDING POLARITY.

I CONDUTTORI DEL CIRCUITO CC DELL'IMPIANTO FV DEVONO ESSERE

IDENTIFICATI IN TUTTI I PUNTI DI TERMINAZIONE, CONNESSIONE E

GIUNZIONE ATTRAVERSO TUTTI I CONDUTTORI. COMPRESA LA

POLARITÀ.

13. MAX DC VOLTAGE AT THE INVERTOR AND/OR DC DISCONNECT MUST

BE 1000V.

LA TENSIONE CC MASSIMA SULL'INVERTER E/O SUL SCOLLEGAMENTO

CC DEVE ESSERE 1000 V.

14. SEE DC ONE LINE DIAGRAM FOR PV SYSTEM ON SHEET EP608A.

VEDERE SCHEMA A UNA LINEA DC PER IMPIANTO FOTOVOLTAICO

SULLA SCHEDA EP608A.

15. SEE PV SYSTEM DETAILS ON SHEETS EK558 AND EK559.

VEDI DETTAGLI IMPIANTO FOTOVOLTAICO SULLE SCHEDE EK558 E

EK559.

16. PV ARRAYS: / ARRAY PC:

120 X 400W PV MODULES / MODULI FV 120 X 400W

12 MODULES PER STRING / 12 MODULI PER STRINGA

10 STRINGS / 10 STRINGHE

MODULE TILT: 5 DEGREES (EQUAL TO ROOF SLOPE)

INCLINAZIONE DEL MODULO: 5 GRADI (PENDENZA PARI ALLA PENDENZA

DEL TETTO)

AZIMUTH: 141.12 DEGREES / AZIMUTO: 141,12 GRADI

PV PRODUCTION:

48.0kW DC 40.0kW AC

1.2 DC/AC RATIO / RAPPORTO DC/AC

42.33 MWH ANNUAL / MWH ANNUALE

NOTES:

NTS

B1

EXAMPLE OF SOLAR PANEL MOUNT

ESEMPIO DI MONTAGGIO A PANNELLO SOLARE

NTS

A1

EXAMPLE OF SOLAR PANEL ROOF MOUNTING

NTS

A2

EXAMPLE OF STANDING SEAM METAL ROOF CLAMP FOR SOLAR PANEL

MOUNTING RAIL

BINARIO DI MONTAGGIO DEL PANNELLO SOLARE DEL MORSETTO DEL TETTO IN METALLO CON AGGANCIO IN PIEDI

ESEMPIO DI MONTAGGIO A TETTO DI PANNELLI SOLARI

PIANTA INGRANDITA-1 IMPIANTO DI FORZA MOTRICE

IA

N T

E I N

G R

A N

D

IT

E I M

P

IA

N T

O D

I F

O R

Z A

M O

T R

IC

E

PIANTA INGRANDITA-2 IMPIANTO DI FORZA MOTRICE

NORD DELLA PIANTA

J

S

N

NB

N P

C

ELECTRICAL

MECHANICAL

PP1- 32,34,36

PP1- 31,33,35

MDP

PP1 PP2 LP1 RP1

SS-105

DDC-03

AHU-01

AHU-02

EF-06

PP1- 7,9,11

PP1- 8,10,12

RP1- 10

RP1- 29

PP2- 18 PP2- 24

P-04

P-03

LCP-1

UH-08

PP2- 14

PP2- 11

LC-1

DDC-01

INVERTER 1

INVERTER 2

AC COMBINER/DISCONNECT

COMBINATORE/SCOLLEGAMENTO AC

4-100mm CONDUITS 750mm

BELOW GRADE FOR

CONTINUTION

SEE DRAWING ES101A

FACU

(NOTE 3)

RP1- 27

PV METER

MISURATORE FV

MDP- 19,21,23

MDP- 26,28,30

SPD

CU-105

VFD-AHU01

VFD-AHU02

VFD-P03

VFD-P04

PP2- 15

POWER IS ROUTED TO CU-105.

SS-105 CONTROLLED BY CU-105.

COORDINATE CONTROL AND

POWER WIRING FOR SS-105 WITH

MECHANICAL SCHEDULES.

L'ALIMENTAZIONE VIENE

INDIRIZZATA A CU-105. SS-105

CONTROLLATA DA CU-105.

COORDINATE DI CONTROLLO E

CABLAGGIO DI POTENZA PER

SS-105 CON SCHEDE MECCANICHE.

600mm X 600mm X 200mm

JUNCTION BOX

2-100mm

J

600mm X 600mm X 200mm JUNCTION BOX

FOR SOLAR SYSTEM CONDUITS. SEE

SHEET EP110A.

SCATOLA DI GIUNZIONE 600mm X 600mm X 200mm PER CONDOTTE IMPIANTI

SOLARI. VEDI SCHEDA EP110A.

M

M E

M

M

3 3

E E

M

1P 30AF

16AT

4P 100A

NF

1P 30AF

16AT

E E

E

1/6

FIRE RISER

COMM

RESTROOM

JANITOR

RP1- 33 RP2- 5

RP1- 7

UH-07

PP2- 10

EF-05

PP2- 12

SS-104

RP2

RP2- 2

RP2- 1

RP2- 3

RP2- 4

PULL STATION

STAZIONE DI TIRO

PULL STATION RESET

RESET DELLA STAZIONE

DI TIRO

PULL STATION AUDIBLE/VISUAL ALARM

ALLARME ACUSTICO/VISO DELLA STAZIONE DI TIRO

IWH-2

PP2- 1,3,5

CU-104

PP2- 13

POWER IS ROUTED TO CU-104. SS-104

CONTROLLED BY CU-104.

COORDINATE CONTROL AND POWER

WIRING FOR SS-104 WITH

MECHANICAL SCHEDULES.

L'ALIMENTAZIONE VIENE INDIRIZZATA

A CU-104. SS-104 CONTROLLATA DA

CU-104. COORDINATE DI CONTROLLO

E CABLAGGIO DI POTENZA PER SS-104

CON SCHEDE MECCANICHE.

(NOTE 2)

3P 60A

NF

1P 30AF

16AT E CT

E

E

1P 30AF

16AT

M 1/20

E

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

SEK

1 : 50

/3

/2

:2 :4

P

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \B

L D

G C

R -1

-E b g ro th e .r v t

E N

LA

R

G E

D P

O W

E R

P

LA

N S

EP401A

BAW BAW JNG

E P

1A

E N

LA

R

G E

D P

O W

E R

P

LA

N S

14121576 162 429

1 : 50 B1

ENLARGED POWER PLAN -1

1 : 50 B4

ENLARGED POWER PLAN -2

43211

1:50

PLAN NORTH

1. FOR GENERAL POWER PLAN NOTES, SEE SHEET EP102A.

PER LE NOTE GENERALI DELL'IMPIANTO DI FORZA MOTRICE,

VEDERE LA TAVOLA EP102A.

2. TWIST-LOCK RECEPTACLE MOUNTED ON LADDER RACK

ABOVE TELECOM RACKS. SEE DETAIL A1 ON SHEET EK557.

PRESA TWIST-LOCK MONTATA SU PORTASCALA SOPRA

PORTATELECOM. VEDI DETTAGLI A1 SULLA SCHEDA EK557.

3. LABEL BREAKER USING RED IDENTIFICATION, NO RCD, (LOCK

OUT) DEVICE. PROVIDE A LABEL INDICATING "FIRE ALARM DO

NOT SWITCH OFF".

INTERRUTTORE DI ETICHETTA UTILIZZO DI IDENTIFICAZIONE

ROSSA, NESSUN DISPOSITIVO RCD, (LOCK OUT). FORNIRE

UN'ETICHETTA CHE INDICA "FIRE ALARM DO NOT SWITCH

OFF".

4. SEE SHEET EK558 FOR HANDICAP EMERGENCY CALL SYSTEM

DETAILS.

VEDERE LA SCHEDA EK558 PER I DETTAGLI DEL SISTEMA DI

CHIAMATA DI EMERGENZA HANDICAP.

SC

HE

M A

UN

IF

IL

AR

E

EL

ET

TR

IC

O

DIAGRAMMA SCHEMA UNIFILARE

ELETTRICO - MDP

P-107 MDP HVAC 1 SET of 3/C-70mm², 1-16mm² G, 50mm C P-106 MDP HP-01 HVAC 1 SET of 3/C-70mm², 1-16mm² G, 50mm C P-105 MDP PANNELLO RP2 1 SET of 4/C-10mm², 1-6mm² G, 25mm C P-104 MDP PANNELLO RP1 1 SET of 4/C-25mm², 1-10mm² G, 25mm C P-103 MDP PANNELLO PP2 1 SET of 4/C-25mm², 1-10mm² G, 25mm C P-102 MDP PANNELLO PP1 1 SETof 4/C-35mm², 1-10mm² G, 40mm C P-101 MDP PANNELLO LP1 1 SET of 4/C-25mm², 1-10mm² G, 25mm C CONDOTTO P-100 UTILITÀ MDP PANNELLO TAVOLA 2 SET of 4/C-185mm², 1-70mm² G, 100mm C BANCA DEI CONDOTTI

TABELLA CAVI

NUMERO CAVI SORGENTE DESTINAZIONE DESCR. CARICO TAGLIA TIPO DI PERCORSO NOTE

PANNELLO TAVOLA

PANNELLO TAVOLA

PANNELLO TAVOLA

PANNELLO TAVOLA

PANNELLO TAVOLA

HP-02

CONDOTTO

CONDOTTO

CONDOTTO

CONDOTTO

CONDOTTO

CONDOTTO

P-108 MDP POTENZA PV 1 SET of 4/C-70mm², 1-16mm² G, 50mm CIMPIANTO PV CONDOTTO

LUNGHEZZA (m)

PANEL RP2

(COMM RM 104)

PANNELLO RP2

(COMM RM 104)

P107P102P101

P100

400AF

400AT

LSIG

4P

PANEL LP1

(ELEC RM105)

PANNELLO LP1

(ELEC RM105)

PANEL PP1

(ELEC RM105)

PANNELLO PP1

(ELEC RM105)

100AF

63AT

4P

SPARE

RICAMBIO

56.6 KW

HP-02 (EXTERIOR)

56.6 KW

HP-02 (ESTERNO)

PANEL PP2

(ELEC RM105)

PANNELLO PP1

(ELEC RM105)

P103 P105 P106 P108

PANEL RP1

(ELEC RM105)

PANNELLO RP1

(ELEC RM105)

P104

PM

TO PV SYSTEM

SEE SHEET EP607A

ALL'IMPIANTO FV

VEDI SCHEDA EP607A

MAIN DISTRIBUTION PANEL - MDP (NOTE 5)

LOCATED IN ELECTRICAL ROOM

400A, 400V, 50HZ, 3 PHASE, 4 WIRE, 22KAIC

QUADRO DI DISTRIBUZIONE PRINCIPALE - MDP (NOTE 5)

SITUATO NELLA CABINA ELETTRICA

400A, 400V, 50HZ, TRIFASE, QUADRIPOLARE, 22KAIC

SPARE

RICAMBIO

SPARE

RICAMBIO

100AF

100AT

4P

100AF

100AT

4P

56.6 KW

HP-01 (EXTERIOR)

56.6 KW

HP-01 (ESTERNO)

100AF

63AT

4P

100AF

100AT

4P

100AF

63AT

4P

100AF

63AT

4P

100AF

32AT

4P

160AF

150AT

3P

160AF

150AT

3P

100AF

32AT

4P

100AF

100AT

4P

200A

NF

200A

NF

400AF

400AT

LSIG

4P

(NOTE 4)

EXISTING

LOW VOLTAGE SWITCHGEAR "QBT SUBST 23"

LOCATED IN BUILDING 1065 (NOTE 3)

ESISTENTE

QUADRO DI BASSA TENSIONE "QBT SUBST 23"

SITUATO IN EDIFICIO 1065 (NOTE 3)

400/5

S

E E

NOTE 6

3P 3P

S P

D

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

NO SCALE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .