Attachment H 1659896dwgVOL1_2of3.pdf
PDF 21 MB Posted
- Solicitation number
- N6247022R3000
About this file
This document provides details on a federal solicitation for construction services. Solicitation Number N6247022R3000 from the Department of the Navy Naval Facilities Engineering Command seeks proposals for Rapid Airfield Damage Recovery Storage Facilities to be located at Aviano Air Base in Italy. Offerors are invited to bid on constructing storage facilities to support rapid repair of airfield infrastructure damaged during combat or natural disaster operations. The solicitation does not specify pricing terms, response deadlines, or anticipated award dates. No incumbent is identified. The attached file appears to contain design drawings for the project scope but its specific contents are not disclosed.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
0 5 10 15 20 30
1:300
SEAL
A/E INFO
2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
D E
P A
R T
M E
N T
O
F
H E
A V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M S
C
M
M A
N D
N O
R F
O L K
V
A
DES DRW CHK
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
A
B
C
D
A
B
C
D
NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018
1659896
A T
L A
N T
I
D
S
I G
N
A
N
S T
R U
C T
I O
N
N6247022R3000
CP GC AA
E X
I S
T I N
G
C
O N
D I T
I O
M
O L
I T
I O
N
S
I T
E
P
L A
N
LD101A
1:300
1:300
EXIST. CONDIT. AND DEMOLITIONS SITE PLAN
14121455
SEAL
A/E INFO
2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
D E
P A
R T
M E
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
N O
R F
O L K
V
A
DES DRW CHK
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
A
B
C
D
A
B
C
D
NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018
1659896
A T
L A
N T
S
I G
N
A
N
S T
R U
C T
I O
N
N6247022R3000
CP GC AA
0 5 10 15 20 30
1:300
D E
S I G
N
S
I T
E
A
P
L A
N T
I N
G
P
L A
N
LS102A
1:300
15700
1:300
DESIGN SITE AND PLANTING PLAN
110800
R=5000
24200
32000
63600
65000
19100
14121456
SEAL
A/E INFO
2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
I P
T I O
N D
A T
E A
P P
R
D E
P A
R T
M E
V
Y N
A V
A L
F
A C
I L I T
I E
S
E
N G
I N
E E
R I N
G
S
Y S
T E
M
M A
N D
N O
R F
O L K
V
A
DES DRW CHK
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
A
B
C
D
A
B
C
D
NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018
1659896
A T
L A
N T
S
I G
N
A
N
S T
R U
C T
I O
N
N6247022R3000
CP GC AA
P L
A N
T
M
A T
E R
I A
L
H
E D
U L
E
A
T
A I L
S
LK501A
NTS
NTS
TREE PLANTING DETAIL (TYP.)
NTS
GROUND COVER PLANTING WITH CURB DETAIL
35grams/sm
NTS
DRAINAGE DEPRESSION WITH GRASS COVER DETAIL
14121457
1. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE
FOLLOWING US CODES:
a. UFC 1-200-01 - DOD BUILDING CODE, OCTOBER 2019
b. UFC 3-301-01 - STRUCTURAL ENGINEERING, 2019
c. IBC2018 - INTERNATIONAL BUILDING CODE, 2018
d. ASCE7-16 - MINIMUM DESIGN LOADS FOR BUILDINGS
AND OTHER STRUCTURES, 2016
e. ACI318-14 - BUILDING CODE REQUIREMENTS FOR
REINFORCED CONCRETE, 2014
f. ANSI-AISC 341-16 - SEISMIC PROVISIONS FOR
STRUCTURAL STEEL BUILDINGS, 2016
g. ANSI-AISC 360-16 - SPECIFICATIONS FOR
STRUCTURAL STEEL BUILDINGS, 2016
2. STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE
FOLLOWING ITALIAN CODES:
a. TECHNICAL NORMS FOR THE CALCULATION, EXECUTION AND TESTING OF NORMAL AND
PRESTRESSED REINFORCED CONCRETE
STRUCTURES AND STEEL STRUCTURES (LAW 1086 -
5/11/1971)
b. TECHNICAL NORMS FOR SEISMIC DESIGN (LAW 64 - 2/2/1974)
c. TECHNICAL CONSTRUCTION CRITERIA (DM 17/01/2018)
d. INSTRUCTIONS FOR THE APPLICATION OF THE
CONSTRUCTION CRITERIA (CIRC.7 - 21/02/2019)
3. DESIGN LOADS
A. SUPERIMPOSED DEAD LOADS
• 1.0 kPa
B. LIVE LOADS (ITALIAN CODE)
• ROOF - CAT. H
0.50 kPa
• GROUND FLOOR - CAT. G
12.00 kPa
C. LIVE LOADS (US CODE)
• ROOF
1.00 kPa
• GROUND FLOOR
12.00 kPa
D. SEISMIC LOADS (ITALIAN CODE)
• SITE CATEGORY
B
• SERVICEABILITY LIFE
Vn=50 years
• OCCUPANCY CLASS
II
• OCCUPANCY FACTOR
Cu=1.0
• REFERENCE LIFE
50 years
• SOIL ACCELERATION FACTOR SLV
ag/g=0.2386
• RETURN PERIOD SLV
475 years
E. SEISMIC LOADS (US CODE)
• SHORT PERIOD SPECTRAL ACCELERATION
Ss=1.25
• ONE SECOND PERIOD SPECTRAL
ACCELERATION S1=0.50
• RISK FACTOR
II
• IMPORTANCE FACTOR IE
IE=1.00
• STRUCTURAL SYSTEM: MOMENT RESISTING
FRAME SYSTEM W/STEEL ORDINARY MOMENT
FRAME
• SITE CLASS
C
• SEISMIC DESIGN CATEGORY:
D
• RESPONSE MODIFICATION AND DEFLECTION
AMPLIFICATION FACTORS: R=3.5, Cd=3.0 (X-
DIR)
F. SNOW LOADS (ITALIAN CODE)
• GROUND SNOW LOAD qk qk=1.50 kPa
• ROOF SHAPE FACTOR µ µ=0.8 (ANGLE<17°)
• ROOF SNOW LOAD qs=1.20 kPa
G. SNOW LOAD (US CODE)
• GROUND SNOW LOAD pg=1.68 kPa
• SNOW LOAD ON ROOF ps=1.06 kPa
H. WIND LOAD (ITALIAN CODE)
• REFERENCE WIND SPEED vb=25 m/s
• SITE CLASS II
• DYNAMIC COEFFICIENT cd=1.0
• WIND LOAD ON WINDWARD FACE
p=0.90 kPa
• WIND LOAD ON LEEWARD FACE
p=0.63 kPa
• WIND LOAD ON SIDES
p=0.54 kPa
DESIGN DATA
1. IL PROGETTO STRUTTURALE E' STATO REALIZZATO IN
CONFORMITA' ALLE SEGUENTI NORMATIVE
AMERICANE:
a. UFC 1-200-01 - REQUISITI GENERALI DELLE
STRUTTURE, GIUGNO 2019
b. UFC 3-301-01 - INGEGNERIA STRUTTURALE, 2019
c. IBC2018 - NORME INTERNAZIONALI DELLE
COSTRUZIONI, 2018
d. ASCE7-16 - CARICHI MINIMI DI PROGETTO PER
EDIFICI ED ALTRE STRUTTURE, 2016
e. ACI318-14 - REQUISITI DI PROGETTO PER
CALCESTRUZZO ARMATO, 2014
f. ANSI-AISC 341-16 - PROVVEDIMENTI ANTISISMICI
PER GLI EDIFICI IN ACCIAIO, 2016
g. AISC360-16 - SPECIFICHE PER EDIFICI IN ACCIAIO
STRUTTURALE, 2016
2. IL PROGETTO E' STATO ESEGUITO IN CONFORMITA'
ALLE SEGUENTI NORMATIVE ITALIANE
a. NORME TECNICHE PER IL CALCOLO, L'ESECUZIONE E IL COLLAUDO DI STRUTTURE IN
CALCESTRUZZO ARMATO NORMALE E
PRECOMPRESSO E DI STRUTTURE IN ACCIAIIO
(LEGGE 1086 - 5/11/1971)
b. NORME TECNICHE PER LE COSTRUZIONI IN ZONA
SISMICA (LEGGE 64 - 2/2/1974)
c. AGGIORNAMENTO ALLE NORME TECNICHE PER
LE COSTRUZIONI (DM 17/01/2018)
d. ISTRUZIONI PER L'APPLICAZIONE DELLE NUOVE
NORME TECNICHE PER LE COSTRUZIONI
(CIRC.7 - 21/02/2019)
3. CARICHI DI PROGETTO:
A. CARICHI PERMANENTI NON STRUTTURALI:
• 1.00 kPa
B. CARICHI VARIABILI (NORMATIVA ITALIANA):
• COPERTURA - CAT. H
0.50 kPa
• PIANO TERRA CAT. G
12.00 kPa
C. CARICHI VARIABILI (NORMATIVA US):
• COPERTURA
1.00 kPa
• PIANO TERRA
12.00 kPa
D. SISMA (NORMATIVA ITALIANA)
• CATEGORIA DI SUOLO
B
• VITA NOMINALE
Vn=50 ANNI
• CLASSE D'USO
II
• FATTORE D'USO
Cu=1.0
• VITA DI RIFERIMENTO
50 ANNI
• COEFFICIENTE DI ACELERAZIONE AL SUOLO
IN SLV ag/g=0.2386
• PERIODO DI RITORNO IN SLV
475 ANNI
E. SISMA (NORMATIVA US)
• ACCELERAZIONE SPETTRALE DI BREVE
PERIODO Ss=1.25
• ACCELERAZIONE AL PERIODO 1 SEC
S1=0.50
• CATEGORIA DI RISCHIO
II
• COEFFICIENTE DI IMPORTANZA
IE=1.00
• SISTEMA STRUTTURALE: TELAIO ORDINARIO
RESISTENTE A MOMENTO
• CATEGORIA TERRENO
C
• CATEGORIA SISMICA DI PROGETTO :
D
• COEFFICIENTE DI RISPOSTA E AMPLIF.
DEFORMAZIONI: R=3.5 , Cd=3.0
F. CARICO DA NEVE (NORMATIVA ITALIANA)
• CARICO AL SUOLO qk qk=1.50 kPa
• COEF.FORMA COPERTURA µ µ=0.8 (ANGOLO<17°)
• CARICO DA NEVE IN COPERTURA
qs=1.20 kPa
G. CARICO DA NEVE (NORMATIVA US)
• CARICO AL SUOLO
pg=1.68 kPa
• CARICO IN COPERTURA
ps=1.06 kPa
H. CARICO DA VENTO (NORMATIVA ITALIANA)
• VELOCITA' DI RIFERIMENTO
vb=25 m/s
• CATEGORIA DI SITO
II
• COEFFICIENTE DINAMICO
cd=1.0
• PRESSIONE PARETI SOPRAVENTO
p=0.90 kPa
• PRESSIONE PARETI SOTTOVENTO
p=0.63 kPa
• PRESSIONE PARETI LATERALI
p=0.54 kPa
• PRESSIONE MASSIMA COPERTURA
(SOLLEVAMENTO) p=1.00 kPa
• PRESSIONE MASSIMA COPERTURA
(COMPRESSIONE) p=0.36 kPa
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
NO SCALE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
/1
/2
:2
:3
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
G E
N E
R A
L N
O T
E S
/2
S-001A
PD AA ES
S -0
A
G E
N E
R A
L N
O T
E S
/2
14121458 44 429
DATI DI PROGETTO
1. CONCRETE AND STEEL STRUCTURE
DIMENSIONS ARE EXPRESSED IN MM.
2. VERTICAL ALTIMETRIC ELEVATIONS ARE
EXPRESSED IN M.
3. SPOT ELEVATION 0.00 AS INDICATED IN CIVIL
DRAWINGS
1. LE QUOTE DELLE STRUTTURE IN CALCESTRUZZO E
IN ACCIAIO SONO ESPRESSE IN MM
2. LE QUOTE ALTIMETRICHE SONO ESPRESSE IN M.
3. LA QUOTA RELATIVA 0.00 E' INDICATA NEI GRAFICI
CIVILI
UNIT OF MEASURE DIMENSION NOTE
NOTA SULLE UNITA' DI MISURA
• MAX WIND LOAD ON ROOF (UPWDS)
p=1.00 kPa
• MIN WIND LOAD ON ROOF (DWNWDS)
p=0.36 kPa
H. WIND LOAD (US CODE)
• BASIC WIND SPEED
148 Km/h
• RISK CATEGORY
II
• VELOCITY PRESSURE EXP. COEFF.
Kz=1.0
• TOPOGRAPHIC FACTOR
Kzt=1.0
• DIRECTIONALITY FACTOR
Kd=0.85
• BUILDING IS PARTIALLY ENCLOSED
• WIND LOAD ON MWFRS
• WIND LOAD ON WINDWARD FACE
p=1.38 kPa
• WIND LOAD ON LEEWARD FACE
p=0.86 kPa
• WIND LOAD ON SIDES
p=1.27 kPa
• MAX WIND LOAD ON ROOF (UPWDS)
p=1.48 kPa
• MIN WIND LOAD ON ROOF (DWNWDS)
p=0.10 kPa
4. FOUNDATIONS
FOUNDATIONS MUST BE SHALLOW TYPE, 50 CM
THICK PLUS 10 CM THICK LEAN CONCRETE LAYER
LAID DOWN AT 1.50 M BELOW GROUND FLOOR
LEVEL. THEY MUST BE CONTINUOUS BEAMS ALONG
THE EDGE, ALONG THE CENTRAL PERPENDICULAR
ALIGNMENT AND UNDERNEATH THE COLUMNS OF
THE RIDGE ALIGNMENT (1600 MM WIDE, 2500 MM
WIDE FOR EDGE MEAMS IN Y-DIR), AND ISOLATED
PADS 2500X2500 SQ.MM, CONNECTED BY TIE BEAMS
300X500 MM
DESIGN BEARING PRESSURES ARE LIMITED TO 200
KN/SQM TO CONTAIN THE SETTLEMENT.
BURIED CONCRETE STRUCTURES MUST BE
PROTECTED THROUGH WATERPROOFING
MEMBRANE.
FROST DEPTH PENETRATION IS 600 MM BELOW
GROUND.
PERMANENT GROUND WATER TABLE IS NOT
EXPECTED.
5. FALL PROTECTION SYSTEM
a. DESIGN IN ACCORDANCE WITH THE FOLLOWING
DOCUMENTS:
• OSHA 1926 S.PART M - 1926:502 - FALL
PROTECTION SYSTEMS CRITERIA AND
PRACTICE
• EM 3851-1,2008 SAFETY AND HEALTH
REQUIREMENTS MANUAL
• UNI-EN 795:2012 PERSONAL FALL
PROTECTION EQUIPMENT - ANCHOR
DEVICES
• DL 81-08SAFEGUARDING HEALTH AND
SAFETY WITHIN WORKPLACES
b. MINIMUM DESIGN LOADS FOR ANCHOR POINTS
(OSHA REQUIREMENTS):
• 13.3 KN SELF RETS. LL AND LANYARD
LIMITING FREE FALL DISTANCE TO 2 FT;
• 22 KN SELF RETS. LL AND LANYARD NOT
LIMITING FREE FALL DISTANCE TO 2 FT;
• 4.0 KN MAX ARREST FORCE FOR EMPLOYEE
USING BODY BELT;
• 8.0 KN MAX ARREST FORCE FOR EMPLOYEE
USING BODY HARNESS;
• 22.0 KN MINIMUM LANYARD BREAKING
STRENGTH
c. MINIMUM DESIGN LOADS FOR ANCHOR POINTS
(UNI EN 795 REQUIREMENTS):
• 12.0 KN CLASS A AND C ANCHOR DEVICES
H. CARICO DA VENTO (NORMATIVA US)
• VELOCITA' BASE DEL VENTO
148 Km/h
• CATEGORIA DI RISCHIO
II
• COEFFICIENTE DI ESPOSIZIONE
Kz=1.0
• COEFFICIENTE TOPOGRAFICO
Kzt=1.0
• COEFFICIENTE DIREZIONALE
Kd=0.85
• PRESSIONE PARETI SOPRAVENTO
p=1.38 kPa
• PRESSIONE PARETI SOTTOVENTO
p=0.86 kPa
• PRESSIONE PARETI LATERALI
p=1.27 kPa
• PRESSIONE MASSIMA COPERTURA
(SOLLEVAMENTO) p=1.48 kPa
• PRESSIONE MASSIMA COPERTURA
(COMPRESSIONE) p=0.10 kPa
4. FONDAZIONI
LE FONDAZIONI SONO DI TIPO DIRETTO, CON
SPESSORE 50 CM E 10 CM DI CALCESTRUZZO
MAGRO, CON INTRADOSSO A -1,5 M DAL PIANO
TERRA. CONSISTERANNO IN TRAVI CONTINUE
LUNGO IL PERIMETRO ED IN CORRISPONDENZA
DEL COLMO E DELLA LINEA MEDIANA DELL'ASSE X
(CON LARGHEZZA 1600 MM IN DIREZIONE X, 2500
MM IN DIREZIONE Y), E PLINTI ISOLATI DI
DIMENSIONE 2500X2500 MMQ COLLEGATI DA
TIRANTI IN C.A. DI SEZIONE 300X500 MM.
I CARICHI DI PROGETTO SONO LIMITATI A 200
KN/MQ PER CONTENERE IL CEDIMENTO.
TUTTE LE STRUTTURE IN CALCESTRUZZO
INTERRATE SARANNO PROTETTE DA UNA
MEMBRANA BITUMINOSA RESISTENTE ALL'ACQUA.
LA PROFONDITA' DI PENETRAZIONE DEL GHIACCIO
E' 600 MM AL DI SOTTO DEL P.C.
NON E' STATA RILEVATA ALCUNA FALDA IDRICA
PERMANENTE
5. LINEA VITA
a. PROGETTARE IN ACCORDO AI SEGUENTI
DOCUMENTI:
• OSHA 1926 S.PART M - 1926:502 - CRITERI
E PRATICA DEI SISTEMI ANTICADUTA
• EM 3851-1,2008 MANUALE PER REQUISITI
DI SICUREZZA E SALUTE
• UNI-EN 795:2012 DISPOSITIVI
ANTICADUTA - DISPOSITIVI DI
ANCORAGGIO
• DL 81-08 SICUREZZA NEI LUOGHI DI
LAVORO
b. CARICHI MINIMI PER I DISPOSITIVI DI
ANCORAGGIO (REQUISITI OSHA):
• 13.3 KN FUNI E CORDINI RETRATTILI CHE
LIMITANO AUTOMATICAMENTE LA CADUTA
LIBERA A 60 cm ;
• 22 KN FUNI E CORDINI RETRATTILI CHE
NON LIMITANO AUTOMATICAMENTE LA
CADUTA LIBERA A 60 cm;
• 4.0 KN FORZA MASSIMA DI ARRESTO PER
ADDETTO CHE UTILIZZA LA CINTURA;
• 8.0 KN FORZA MASSIMA DI ARRESTO PER
ADDETTO CHE UTILIZZA IMBRAGATURA
• 22.0 KN CARICO MINIMO DI ROTTURA DEL
CORDINO
c. CARICHI MINIMI PER I DISPOSITIVI DI
ANCORAGGIO (REQUISITI UNI EN 795 ):
• 12.0 KN DISPOSITIVI DI ANCORAGGIO
CLASSE A E C
N O
T E
G E
N E
R A
LI
/2
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
NO SCALE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
/1
/2
:2
:3
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
G E
N E
R A
L N
O T
E S
/2
S-002A
PD AA ES
S -0
A
G E
N E
R A
L N
O T
E S
/2
14121459 45 429
1. CONCRETE:
A. NON STRUCTURAL CONCRETE
C12/15 - f'c=12 MPa (CYLINDRICAL)
B. STRUCTURAL CAST-IN-PLACE CONCRETE
C35/45 - f'c=35 MPa (CYLINDRICAL)
EXPOSURE CLASS XC2
MAX SIZE AGGREGATE 20 MM
CONSISTENCY S4
MAX w/c = 0,5
C. CAST-IN- PLACE CONCRETE FOR SLAB ON GRADE
C30/35 - f'c=30 MPa (CYLINDRICAL)
EXPOSURE CLASS XC2
MAX SIZE AGGREGATE 20 MM
CONSISTENCY S4
MAX w/c = 0,5
2. STEEL FOR REINFORCEMENT:
A. B450C, YIELD STRENGTH
fy=450 MPa
3. CONCRETE COVER
A. CONCRETE THICKNESS COVERING
REINFORCEMENT MUST NOT BE LESS THAN ONE
BAR DIAMETER AND NOT LESS THAN SPECIFIED
IN THE EXAMPLES LISTED BELOW.
a. CONCRETE CAST AGAINST EARTH
75 MM
b. CONCRETE CAST AGAINST FORMS AND
EXPOSED TO WEATHER 50 MM
c. CONCRETE CAST AGAINST FORMS AND NOT
EXPOSED TO WEATHER:
• SLABS, JOISTS,
25 M
• WALLS (COVER ON HORIZ. EXT. BARS)
25 MM
• BEAMS AND COLUMNS (PRIMARY
REINFORCEMENT, STIRRUPS) 40 MM
4. MINIMUM CLEAR SPACING BETWEEN PARALLEL
REINFORCING BARS MUST BE GREATER THAN RE-BAR
DIAMETER BUT NOT LESS THAN 25MM.
5. EXPOSED CONCRETE EDGES MUST BE CHAMFERED
15 MILLIMETERS UNLESS OTHERWISE SHOWN.
6. NO CONCRETE MAY BE PLACED UNTIL EMBEDDED
WORK AND EXCAVATION HAVE BEEN INSPECTED BY
THE QUALITY CONTROL ORGANIZATION. THE
CONTRACTING OFFICER MUST BE NOTIFIED 24 HOURS
IN ADVANCE OF THE INSPECTION.
7. REINFORCING STEEL MUST BE HELD SECURELY IN
PLACE TO PREVENT DISLOCATION DURING
CONCRETE POURING OPERATIONS.
8. USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH
CIVIL, ARCHITECTURAL, MECHANICAL, PLUMBING,
FIRE PROTECTION AND ELECTRICAL DRAWINGS IN
ORDER TO PREPARE SHOP DRAWINGS. COORDINATE
THE REQUIREMENTS OF THE WORK OF OTHER
TRADES AS TO SLEEVES, INSERTS, HOLES, HANGERS,
CHASES, ANCHORS, ETC. SHOP DRAWINGS MUST
INCLUDE ALL HOLES FOR MECHANICAL, FP,
ELECTRICAL AND TELECOMM SERVICE
PENETRATIONS SO THAT NO HOLES MAY BE ADDED
AFTER THE CONSTRUCTION OF THE CONCRETE
STRUCTURES.
9. ELECTRICAL CONDUIT, INSERTS, BOXES AND OTHER
ITEMS THAT ARE BEING EMBEDDED IN CONCRETE
WORK MUST BE COORDINATED AND PLACED BEFORE
CONCRETE IS PLACED. MAINTAIN THREE DIAMETERS
CLEARANCE BETWEEN CONDUITS. SEE MECHANICAL
AND ELECTRICAL DWGS.
CONCRETE CONSTRUCTION NOTES
1. STRUCTURAL SHAPES, BARS, PLATES AND RODS
MUST CORRESPOND TO UNI STANDARD EN 10025, EN
10210, EN 10219-1 ALL HAVING CE MARKING. SHAPES
MUST CORRESPOND TO THE FOLLOWING:
• STEEL TYPE S355, YIELDING fyk=355 MPa
• ULTIMATE TENSILE STRENGTH ftk=530 MPa.
2. FASTENERS FOR STRUCTURAL CONNECTIONS (UNI EN
898-1 AND UNI 5592:1968 AND EN ISO 4016:2002) MUST
CORRESPOND TO THE FOLLOWING:
• CLASS 8.8, YIELDING fyb=640 MPa
• TENSILE STRENGTH ftk=800 MPa
3. ANCHOR BOLTS MUST BE CONFORMING TO UNI EN
10025 CLASS S355.
4. WELDINGS TYPE E70XX IF NOT DIFFERENTLY
INDICATED. WELDS MUST DEVELOP THE FULL
STRENGTH OF THE WEAKER CONNECTED MEMBER.
5. BOLT HOLES MAY NOT BE CUT OR ENLARGED BY
FLAME CUTTING IN THE FIELD.
6. STEEL MEMBERS MUST BE HOT-DIP GALVANIZED
7. IF FLASH RUSTING OCCURS, APPLY PRIMER TO A
MINIMUM DRY FILM THICKNESS OF 0.05 MM, IN
ACCORDANCE WITH SPEC 05 12 00.
8. GROUT USED UNDER BEARING PLATES MUST BE NON
SHRINK, NON METALLIC, PRE-MIXED GROUT AND HAVE
A MINIMUM 55 MPa COMPRESSIVE STRENGTH
STEEL CONSTRUCTION NOTES
1. TUTTI I PROFILI STRUTTURALI, BARRE, PIASTRE E
TIRANTI SARANNO CONFORMI ALLA UNI EN 10025, EN
10210, EN 10219-1, E AVRANNO TUTTI LA
MARCHIATURA CE. TUTTI I SOPRA CITATI ELEMENTI
AVRANNO LE SEGUENTI CARATTERISTICHE:
• ACCIAIO TIPO S 355, SNERVAMENTO fyk=355 MPa
• RESISTENZA ULTIMA ftk=530 MPa.
2. TUTTI I BULLONI PER LE UNIONI STRUTTURALI (UNI EN
898-1, UNI 5592:1968 E EN ISO 4016:2002) SARANNO DI
CLASSE 8.8, E AVRANNO PERTANTO LE SEGUENTI
PROPRIETA':
• SNERVAMENTO fyb=640 MPa
• RESISTENZA ULTIMA ftk=800 MPa
3. I TIRAFONDI SARANNO REALIZZATI IN CONFORMITA'
CON UNI EN 10025 CLASSE S355.
4. LE SALDATURE SARANNO DEL TIPO E70XX SE NON
DIVERSAMENTE INDICATO, E DOVRANO RIPRISTINARE
LA RESISTENZA COMPLETA DELL'ELEMENTO
COLLEGATO PIU' DEBOLE.
5. I FORI PER I BULLONI NON POTRANNO ESSERE
TAGLIATI O ALLARGATI IN SITU CON CANNELLO.
6. TUTTI GLI ELEMENTI IN ACCIAIO STRUTTURALE
DEVONO ESSERE ZINCATI A CALDO.
7. IN CASO DI FORMAZIONE DI RUGGINE, APPLICARE
UNO SPESSORE MINIMO DI VERNICE PROTETTIVA
PARI A 0.05 MM COME DA SPECIFICA 05 12 00
8. LA MALTA DA UTILIZZARE COME RIEMPIMENTO AL DI
SOTTO DELLE PIASTRE METALLICHE DOVRA' ESSERE
A RITIRO COMPENSATO, NON METALLICA,
PREMISCELATA, E DOVRà AVERE UNA RESISTENZA MINIMA A COMPRESSIONE DI 55 MPa.
NOTE DI COSTRUZIONE DEL CALCESTRUZZO
1. CALCESTRUZZO:
A. CALCESTRUZZO NON STRUTTURALE
C12/15 - f'c=12 MPa (CILINDRICO)
B. CALCESTRUZZO STRUTTURALE IN OPERA
C35/45 - f'c=35 MPa (CILINDRICO)
CLASSE DI ESPOSIZIONE XC2
MASSIMA DIMENSIONE AGGREGATO 20 MM
CONSISTENZA S4
MASSIMO a/c = 0,5
C. CALCESTRUZZO IN OPERA PER SOLETTA CONTRO
TERRA
C30/35 - f'c=30 MPa (CILINDRICO)
CLASSE DI ESPOSIZIONE XC2
MASSIMA DIMENSIONE AGGREGATO 20 MM
CONSISTENZA S4
MASSIMO a/c = 0,5
2. ACCIAIO PER ARMATURE:
A. B450C, SNERVAMENTO fy=450 MPa
3. COPRIFERRI
I COPRIFERRI MINIMI DOVRANNO ESSERE NON
MINORI DI UN DIAMETRO, E COMUNQUE NON MINORI
DI QUANTO DI SEGUITO SPECIFICATO:
A. CALCESTRUZZO IN OPERA (NON
PRECOMPRESSO)
a. GETTATO CONTRO TERRA 75 MM
b. GETTATO CONTRO CASSERO ED ESPOSTO AGLI
AGENTI ATMOSFERICI 50 MM
c. GETTATO CONTRO CASSERO E NON ESPOSTO
AGLI AGENTI ATMOSFERICI:
• SOLETTE, TRAVETTI 25 MM
• PARETI (COPR. SULLA BARRA ORIZZ, EST.)
25 MM
• TRAVI E PILASTRI (ARMATURE
LONGITUDINALI, STAFFE) 40 MM
4. GLI INTERFERRI MINIMI SARANNO PARI AL DIAMETRO
DELLA BARRA MA IN NESSUN CASO INFERIORI A 25
MM.
5. TUTTI GLI SPIGOLI ESPOSTI DI CALCESTRUZZO
SARANNO SMUSSATI DI 15 MM SE NON
DIVERSAMENTE INDICATO.
6. NON SI ESEGUIRANNO GETTI DI CALCESTRUZZO
FINCHE' TUTTI GLI ELEMENTI E GLI SCAVI NON
SARANNO ISPEZIONATI DAL RESPONSABILE DEL
CONTROLLO DI QUALITA'. L'UFFICIALE CONTRAENTE
DOVRA' ESSERE AVVISATO DEL GETTO 24 ORE PRIMA
DELL'ISPEZIONE.
7. TUTTE LE ARMATURE SARANNO SALDAMENTE
BLOCCATE PER EVITARNE LO SPOSTAMENTO
DURANTE LE OPERAZIONI DI GETTO.
8. L'APPALTATORE DOVRA' UTILIZZARE I DISEGNI
STRUTTURALI INSIEME AI CIVILI, ARCHITETTONICI,
MECCANICI, IDRAULICI, ELETTRICI,
TELECOMUNICAZIONI E PROTEZIONE INCENDIO PER
PREPARARE I DISEGNI DI CANTIERE. DOVRA' INOLTRE
COORDINARE IL LAVORO DEI SUBAPPALTATORI PER
ATTRAVERSAMENTI, INSERTI, FORI, ANCORAGGI ETC.
I DISEGNI DI CANTIERE DOVRANNO INCLUDERE LE
FOROMETRIE MECCANICHE, ANTIINCENDIO,
ELETTRIHE, E TELECOMUNICAZIONI, PER EVITARE LA
REALIZZAZIONE DI FOROMETRIE NELLE STRUTTURE
IN CALCESTRUZZO DOPO LA LORO COSTRUZIONE.
9. LE CANALINE ELETTRICHE, GLI INSERTI, LE CASSETTE
ED ALTRI ELEMENTI DA ANNEGARE NEL
CALCESTRUZZO DOVRANNO ESSERE COORDINATI E
COLLOCATI PRIMA CHE IL CALCESTRUZZO SIA POSTO
IN OPERA. MANTENERE TRE DIAMETRI DI SPAZIO TRA
LE CANALINE. FARE RIFERIMENTO AI GRAFICI
MECCANICI ED ELETTRICI..
NOTE DI COSTRUZIONE DEL'ACCIAIO
1. STEEL DECK MUST COMPLY WITH REQUIREMENTS
OF APPLICABLE ITALIAN NORMS AND CODES.
2. PROVIDE HEAVY DUTY STEEL DECK TO RESIST THE
FOLLOWING WIND LOADING CONDITIONS:
DOWNWARDS: 0.30 kPa UPWARDS: 2.16 kPa (ZONE 3)
1.92 kPa (ZONE 2)
1.44 kPa (ZONE 1)
1.00 kPa (ZONE 1')
3. ROOF DECK MUST BE INSTALLED SO THAT FLUTES
RUN PERPENDICULAR TO FRAMING MEMBERS. DECK
MUST SPAN ON THREE SUPPORTS MIN. WHERE
POSSIBLE.
4. LIGHTWEIGHT ITEMS: LW CEILINGS, DUCTS, LIGHT
FIXTURES ETC., MAY BE HUNG FROM DECK. DO NOT
HANG OTHER ITEMS FROM ROOF DECK WITHOUT
APPROVAL.
5. OPENINGS IN DECK ARE NOT ALLOWED IF NOT
SPECIFICALLY INDICATED ON DRAWINGS OR
APPROVED BY THE CONTRACTING OFFICER.
6. FASTEN STEEL DECK TO THE MAIN FRAMING IN
ACCORDANCE TO MANUFACTURER'S
INSTRUCTIONS.
STEEL DECK NOTES NOTE LAMIERA GRECATA IN ACCIAIO
1. LA LAMIERA DI COPERTURA DOVRA' RISPETTARE
TUTTE LE LEGGI E NORMATIVE APPLICABILI IN ITALIA
2. FORNIRE UNA LAMIERA GRECATA IN ACCIAIO PER
CARICHI PESANTI CAPACE DI RESISTERE ALLE
SEGUENTI SOLLECITAZIONI DEL VENTO:
VERSO IL BASSO: 0.3 kPa VERSO L'ALTO: 2.16 kPa (ZONA 3)
1.92 kPa (ZONA 2)
1.44 kPa (ZONA 1)
1.00 kPa (ZONA 1')
3. INSTALLARE LA LAMIERA GRECATA IN MANIERA
TALE CHE I SOLCHI SIANO PERPENDICOLARI AGLI
ELEMENTI STRUTTURALI DI SUPPORTO. LA LAMIERA
DEVE POGGIARE ALMENO SU TRE SUPPORTI
LADDOVE POSSIBILE.
4. ELEMENTI LEGGERI COME CONTROSOFFITTI
LEGGERI, LAMPADE, CANALI POTRANNO ESSERE
COLLEGATE DIRETTAMENTE ALLA LAMIERA. NON
APPENDERE ALTRI ELEMENTI SENZA ESPLICITA
APPROVAZIONE.
5. LE APERTURE NELLA LAMIERA NON SONO
CONSENTITE SE NON SPECIFICAMENTE INDICATE
NEI GRAFICI O APPROVATE DALL'UFFICIALE
CONTRAENTE.
6. COLLEGARE LA LAMIERA ALLA STRUTTURA
PORTANTE SEGUENDO LE INDICAZIONI DEL
PRODUTTORE.
N O
T E
G E
N E
R A
LI
/2
1. FALL PROTECTION SYSTEM MUST BE DESIGNED BY
A REGISTERED ENGINEER. CONTRACTOR MUST
SUBMIT DRAWINGS AND CALCULATIONS TO USG
AND DOR SIGNED AND SEALED FOR APPROVAL.
2. CONTRACTOR MUST SUBMIT TECHNICAL DATA
SHEET THAT CERTIFIES COMPLIANCE TO UNI EN 795,
OR OSHA REQUIREMENTS, WHICHEVER IS MORE
STRINGENT.
3. ALL DIMENSIONS INDICATED IN CONSTRUCTIONS
DETAILS MUST BE VERIFIED WITH THE ACTUAL
GEOMETRY PRIOR TO PROVIDE FPS DESIGN.
4. THE ANALYSIS IS REFERRED TO A SPECIFIC
GEOMETRY OF THE FALL PROTECTION SYSTEM
DEVICE SUPPORT SYSTEM, AND MAY VARY
ACCORDING TO THE SPECIFIC PRODUCT SELECTED
BY THE CONTRACTOR.
5. EACH UNI EN 795 CLASS C DEVICE MUST BE
PROVIDED WITH AN ENERGY DISSIPATING DEVICE
AS FORESEEN BY MANUFACTURER'S TECHNICAL
DATA SHEET, UNLESS OTHERWISE DISPOSED IN THE
SAME DOCUMENT.
6. AFTER COMPLETION OF FPS INSTALLATION,
PROVIDE A COMPLETE TECHNICAL BROCHURE
INCLUDING MAINTENANCE MANUAL TO THE
CONTRACTING OFFICER. AN ACCESS SIGN MUST BE
POSITIONED IN PROXIMITY OF ROOF ACCESS.
7. ANCHORAGE EFFICIENCY OF THE FPS MUST BE
TESTED PRIOR TO PUT IN SERVICE THE SYSTEM.
FALL PROTECTION SYSTEM NOTES
1. LE LINEE VITA DEVONO ESSERE PROGETTATE DA
UN INGEGNERE ABILITATO. L'APPALTATORE DOVRA'
SOTTOMETTERE PER APPROVAZIONE AD USG E DOR
DISEGNI ESECUTIVI E RELAZIONE DI CALCOLO.
2. L'APPALTATORE DOVRA' SOTTOMETTERE I DATI
TECNICI CHE CERTIFICHINO IL RISPETTO ALLA UNI
795, O AI REQUISITI OSHA LADDOVE PIU'
RESTRITTIVI.
3. TUTTE LE DIMENSIONI INDICATE NEI PARTICOLARI
COSTRUTTIVI DOVRANNO ESSERE VERIFICATE ED
ADEGUATE ALLA GEOMETRIA EFFETTIVA PRIMA DI
PROVEDERE AL PROGETTO DELLA LINEA VITA.
4. L'ANALISI E' RIFERITA AD UNA SPECIFICA
GEOMETRIA DEL SISTEMA ANTICADUTA, E POTRA'
VARIARE IN DIPENDENZA DELLO SPECIFICO
PRODOTTO SELEZIONATO DALL'APPALTATORE.
5. OGNI DISPOSITIVO UNI EN 795 CLASSE C DOVRA'
ESSERE EQUIPAGGIATO CON UN DISPOSITIVO DI
DISSIPAZIONE DELL'ENERGIA COME PREVISTO FAL
MANUALE TECNICO DEL PRODUTTORE, A MENO CHE
NON SIA DIVERSAMENTE DISPOSTO NELLO STESSO
DOCUMENTO.
6. DOPO AVER INSTALLATO LA LINEA VITA FORNIRE
ALL'UFFICIALE CONTRAENTE DOCUMENTAZIONE
TECNICA COMPLETA, INCLUSO IL MANUALE DI
MANUTENZIONE. UN CARTELLO DI ACCESSO DOVRA'
ESSERE POSIZIONATO IN PROSSIMITA'
DELL'ACCESSO AL TETTO.
7. L'EFFICIENZA DEI DISPOSITIVI DI ANCORAGGIO
DOVRA' ESSERE VERIFICATA PRIMA DI METTERE IN
FUNZIONE IL SISTEMA.
NOTE PER LE LINEE VITA
B1
SB201A
C1
SB202A
B1
SB202A
A1
SB201A
1 2 3 4 5 6 7 8 9
SB102A
A1
SB103A
A1
A
B
C
D
E
8500 8000 8000 8000 8000 8500
65000
SF401A
C3
67500
8000 8000
5 0 5 10 15
1:200
KEY PLAN
PIANTA DI RIFERIMENTO
BA
NORD DELLA PIANTA
PLAN NORTH
1 : 200
OVERALL FOUNDATION PLAN
C1 PIANTA GENERALE DELLE FONDAZIONI
1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001A AND
S002A.
PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO
ALLE TAVOLE S001A E S002A.
2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO
ARCHITECTURAL AND CIVIL DRAWINGS.
PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE
RIFERIMENTO AI DISEGNI ARCHITETTONICI E CIVILI.
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
1 : 200
/1
/2
:2
:3
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
O V
E R
A
LL
F O
U N
D A
T
IO
N P
LA
N
SB101A
PD AA ES
S B
1A
O V
E R
A
LL
F O
U N
D A
T
IO
N P
LA
N
14121460 46 429
GENERAL SHEET NOTES:
NOTE GENERALI DEL DISEGNO :
P
IA
N T
A G
E N
E R
A L
E D
E L
L E
F O
N D
A Z
IO
1 2 3 4 5
8500 8000 8000 8000
A
B
C
D
E
2500 7100 300 7700 300 7700 300
B1
SF301A
B1
SF301A
C1
SF301A
C1
SF301A
7050 1600
6 74
-1000
-1000
-1000
-1000
SK554
A1
-1000
-1000
M A
T C
H
LI
N E
S
E E
A
O N
S H
E E
T S
B
3A
2180 6000 2000 6000 2000 6000 2000 6000 2000
2500 5500 2500
SK555
C1
SK552
C3
SK551
B1
B4
SK551
B4
SK551
C1
SR301A
C1
SR301A
B3
SK551
B3
SK551
6100 100
B1
SK567
B1
SK567
LI
N
E A
D I C
O
LL
E G
A M
E N
T O
V
E D
I A
S U
T A
V . S
B
3A
1 : 100SB101A
FOUNDATION PLAN - AREA A
A1 PIANTA FONDAZIONI - AREA A KEY PLAN
PIANTA DI RIFERIMENTO
BA
1 0 1 2 3 4 5 6 7 8 9
1:100
NORD DELLA PIANTA
PLAN NORTH
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
1 : 100
/1
/2
:2
:4
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
F O
U N
D A
T
IO
N P
LA
N
A
R E
A A
SB102A
PD AA ES
S B
2A
F O
U N
D A
T
IO
N P
LA
N
A
R E
A A
14121461 47 429
KEY #
KEYED NOTES / NOTE CHIAVE
ENGLISH NOTE NOTA ITALIANA
1 COLUMN HEB320 COLONNA HEB320
2 R.C. FOOTING 2500x2500x500 PLINTO IN C.A. 2500x2500x500
3 R.C. TIE BEAM 300x500 TRAVE DI COLLEGAMENTO IN C.A. 300x500
4 R.C. FOUNDATION BEAM 1600x500 TRAVE DI FONDAZIONE IN C.A. 1600x500
5 R.C. FOUNDATION BEAM 2500x500 TRAVE DI FONDAZIONE IN C.A. 2500x500
6 R.C. INTERNAL WALL (h=2200 mm) MURO INTERNO IN C.A. (h=2200 mm)
7 R.C. EXTERNAL WALL (h=1220 mm) MURO ESTERNO IN C.A. (h=1220 mm)
8 SERVICE AREA AREA SERVIZI
9 PROVIDE STEEL COLUMN BASE
PLATE PRIOR TO CASTING THE
CORNER WALL
INSTALLARE IL PILASTRO IN ACCIAIO
PRIMA DI GETTARE IL MURO D'ANGOLO
10 BOLLARD DISSUASORE
11 REMOVABLE BOLLARD DISSUASORE RIMOVIBILE
1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001A AND
S002A.
PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO
ALLE TAVOLE S001A E S002A.
2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO
ARCHITECTURAL AND CIVIL DRAWINGS.
PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE
RIFERIMENTO AI DISEGNI ARCHITETTONICI E CIVILI.
3. COORDINATE OPENING IN CONCRETE WALL FOR UTILITY PENETRATIONS
REFER TO MECHANICAL, ELECTRICAL AND FIRE DRAWINGS PRIOR TO
SUBMITTAL OF REBAR SHOP DRAWINGS.
COORDINARE LE APERTURE NEI MURI IN C.A. PER ATTRAVERSAMENTI DI
LINEE DI SERVIZIO. FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E
ANTINCENDIO PRIMA DI SOTTOMETTERE I DISEGNI ESECUTIVI DELLE BARRE
DI ARMATURA.
GENERAL SHEET NOTES:
NOTE GENERALI DEL DISEGNO :
P
IA
N T
A F
O N
D A
Z
IO
N I -
A R
E
5 6 7 8 9
A1
SF301A
A1
SF301A
8000 8000 8500
A
B
C
D
E
300 7700 300 7700 300
7100 2500
C1
SF301A
C1
SF301A
1600 7050
6 7
34 5
6 7
-1000
-1000
-1000
-1000
-1000
-1000
-1000
M A
T C
H
LIN
E
S E
E A
1 O N
S H
E E
T S
B 102A
2000 6000 2000 6000 2000 6000 2000 6000 2180
B4
SK551
B4
SK551
2500 5500 2500
LIN
E
A D
I C O
LLE
G
A M
E N
T O
V
E D
I A 1 S
U T
A V
. S B
102A
1 : 100SB101A
FOUNDATION PLAN - AREA B
A1 PIANTA FONDAZIONI - AREA B
1 0 1 2 3 4 5 6 7 8 9
1:100
KEY PLAN
PIANTA DI RIFERIMENTO
BA
NORD DELLA PIANTA
PLAN NORTH
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
1 : 100
/1
/2
:2
:4
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
F O
U N
D A
T
IO
N P
LA
N
A
R E
A B
SB103A
PD AA ES
S B
3A
F O
U N
D A
T
IO
N P
LA
N
A
R E
A B
14121462 48 429
KEY #
KEYED NOTES / NOTE CHIAVE
ENGLISH NOTE NOTA ITALIANA
1 COLUMN HEB320 COLONNA HEB320
2 R.C. FOOTING 2500x2500x500 PLINTO IN C.A. 2500x2500x500
3 R.C. TIE BEAM 300x500 TRAVE DI COLLEGAMENTO IN C.A. 300x500
4 R.C. FOUNDATION BEAM 1600x500 TRAVE DI FONDAZIONE IN C.A. 1600x500
5 R.C. FOUNDATION BEAM 2500x500 TRAVE DI FONDAZIONE IN C.A. 2500x500
6 R.C. INTERNAL WALL (h=2200 mm) MURO INTERNO IN C.A. (h=2200 mm)
7 R.C. EXTERNAL WALL (h=1220 mm) MURO ESTERNO IN C.A. (h=1220 mm)
8 SERVICE AREA AREA SERVIZI
9 PROVIDE STEEL COLUMN BASE
PLATE PRIOR TO CASTING THE
CORNER WALL
INSTALLARE IL PILASTRO IN ACCIAIO
PRIMA DI GETTARE IL MURO D'ANGOLO
10 BOLLARD DISSUASORE
11 REMOVABLE BOLLARD DISSUASORE RIMOVIBILE
1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001A AND
S002A.
PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO
ALLE TAVOLE S001A E S002A.
2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO
ARCHITECTURAL AND CIVIL DRAWINGS.
PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE
RIFERIMENTO AI DISEGNI ARCHITETTONICI E CIVILI.
3. COORDINATE OPENING IN CONCRETE WALL FOR UTILITY PENETRATIONS
REFER TO MECHANICAL, ELECTRICAL AND FIRE DRAWINGS PRIOR TO
SUBMITTAL OF REBAR SHOP DRAWINGS.
COORDINARE LE APERTURE NEI MURI IN C.A. PER ATTRAVERSAMENTI DI
LINEE DI SERVIZIO. FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E
ANTINCENDIO PRIMA DI SOTTOMETTERE I DISEGNI ESECUTIVI DELLE BARRE
DI ARMATURA.
GENERAL SHEET NOTES:
NOTE GENERALI DEL DISEGNO :
P
IA
N T
A F
O N
D A
Z
IO
N I -
A R
E
B
C1
SB202A
B1
SB202A
A1
SB201A
1 2 3 4 5 6 7 8 9
A
B
C
D
E
1650016500
4390 4390 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4390 4390
4000 4000
16000 16000
SK552
B4
SK552
B5SR304A
C1
CTJCTJ CTJ CTJ CTJ CTJ CTJ CTJ
CTJ CTJ CTJ CTJ CTJ CTJ CTJ
CTJ CTJ CTJ CTJ CTJ CTJ CTJ
CTJ CTJ CTJ CTJ CTJ CTJ CTJCTJ
CJCJCJ
CJCJCJ
CJCJCJ
CJCJCJ
CTJ CTJ CTJ CTJCTJCTJCTJ
CTJ CTJ CTJCTJCTJCTJ
CTJ CTJ CTJCTJCTJCTJ
CTJ CTJ CTJCTJCTJ
CTJ
CTJ CTJ
CTJ
CTJ
CJ CJ CJ
CTJ CTJ CTJ CTJ
CTJ CTJ CTJ CTJ
CJCJCJ
1580 2000
1900 1900 1900 1300
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
1 : 200
/1
/2
:2
:4
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
S
LA
B O
N G
R A
D E
P
LA
N
SB104A
PD AA ES
S B
4A
S
LA
B O
N G
R A
D E
P
LA
N
14121463 49 429
1 : 200
SLAB ON GRADE PLAN
C1 PIANTA SOLETTA A TERRA
3 3 3
4 2
5 0 5 10 15
1:200
NORD DELLA PIANTA
PLAN NORTH
1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001A AND
S002A.
PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO
ALLE TAVOLE S001A E S002A.
2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO
ARCHITECTURAL DRAWINGS.
PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE
RIFERIMENTO AI DISEGNI ARCHITETTONICI.
GENERAL SHEET NOTES:
NOTE GENERALI DEL DISEGNO :
5 6
P
IA
N T
A D
E
LL
A S
O
LE
T T
A A
T E
R R
A
KEY PLAN
PIANTA DI RIFERIMENTO
BA
KEY #
KEYED NOTES / NOTE CHIAVE
ENGLISH NOTE NOTA ITALIANA
1 R.C. SLAB ON GRADE THICK. 220 mm SOLETTA IN C.A. SPESSORE 220 mm
2 CONSTRUCTION JOINT (CJ). SEE
DETAIL A2 ON SHEET SK552
GIUNTO DI COSTRUZIONE. VEDERE
DETTAGLIO A2 ALLA TAVOLA SK552
3 CONTROL JOINT (CTJ). SEE DETAIL
A1 ON SHEET SK552
GIUNTO DI CONTROLLO. VEDERE
DETTAGLIO A1 ALLA TAVOLA SK552
4 EXPANSION JOINT (CEJ) BETWEEN
MAT SLAB AND R.C. WALL FOR FULL
HEIGHT OF SLAB. SEE DETAIL A3 ON
SHEET SK552
GIUNTO DI ESPANSIONE TRA LA SOLETTA
ED I MURI IN C.A. PER TUTTO LO SPESSORE
DELLA SOLETTA. VEDERE DETTAGLIO A3
ALLA TAVOLA SK552
5 COLUMN EXPANSION/ISOLATION
JOINT. SEE DETAIL A3 ON SHEET
SK552
GIUNTO DI ESPANSIONE/ISOLAMENTO
DELLA COLONNA. VEDERE DETTAGLIO A3
ALLA TAVOLA SK552
6 THICKENED EDGE. SEE SECTION C1
ON SHEET SK552
BORDO RINGROSSATO. VEDERE SEZIONE
C1 ALLA TAVOLA SK552
7 R.C. APRON AT PEDESTRIAN DOOR.
SEE DETAIL B1 ON SHEET SK567
PIAZZOLA IN C.A. AGLI INGRESSI PEDONALI.
VEDERE DETTAGLIO B1 ALLA TAVOLA SK567
8 R.C. APRON AT ROLL UP DOOR. SEE
DETAIL C1 ON SHEET SK567
PIAZZOLA IN C.A. AI VARCHI CARRABILI.
VEDERE DETTAGLIO C1 ALLA TAVOLA SK567
9 STANDARD BOLLARD - INTERNAL.
SEE DETAL A2 ON SHEET SK567
DISSUASORE STANDARD - INTERNO.
VEDERE DETTAGLIO A2 ALLA TAVOLA SK567
10 STANDARD BOLLARD - EXTERNAL.
SEE DETAL A1 ON SHEET SK567
DISSUASORE STANDARD - ESTERNO.
VEDERE DETTAGLIO A1 ALLA TAVOLA SK567
11 REMOVABLE BOLLARD - SEE DETAL
A3 ON SHEET SK567
DISSUASORE RIMOVIBILE - VEDERE
DETTAGLIO A3 ALLA TAVOLA SK567
FOUND
-1000
EAVE TOS
123456789
FIRST FLOOR
DOOR
L.C.
-1500
85008000800080008000800080008500
SK561
A1
1170 6240 1760 6240 1760 6240
SK562
A1
SK565
A1
SK563
A4
GRONDA TOS
LIV. PORTE
PRIMO PIANO
FOND.
MAGRONE
FOUND
-1000
EAVE TOS
1 2 3 4 5 6 7 8 9
FIRST FLOOR
DOOR
L.C.
-1500
8500 8000 8000 8000 8000 8000 8000 8500
1170 6240 1760 6240
SK565
D1
GRONDA TOS
LIV. PORTE
PRIMO PIANO
FOND.
MAGRONE
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
1 : 100
/1
/2
:2
:5
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
E
LE
V A
T
IO
N O
N A
X
IS
SB201A
PD AA ES
S B
1A
E
LE
V A
T
IO
N O
N A
X
IS
14121464 50 429
1 : 100SB101A
ELEVATION ON AXIS
B1 PROSPETTO SU ASSE
1 : 100SB101A
ELEVATION ON AXIS
A1 PROSPETTO SU ASSE
KEY #
KEYED NOTES / NOTE CHIAVE
ENGLISH NOTE NOTA ITALIANA
1 COLUMN HEB320 COLONNA HEB320
2 BEAM HEB220 TRAVE HEB220
3 COLUMN IPE160 COLONNA IPE160
4 GIRT UPN 200 ARCARECCIO UPN200
5 SHS 150x16 TRAVE TUBOLARE 150x16
6 OVERHEAD DOOR. SEE
ARCHITECTURAL DRAWINGS
PORTA BASCULANTE. VEDERE I
DISEGNI ARCHITETTONICI
1 0 1 2 3 4 5 6 7 8 9
1:100
3 4
3 4
1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001A AND
S002A.
PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO
ALLE TAVOLE S001A E S002A.
2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO
ARCHITECTURAL DRAWINGS.
PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE
RIFERIMENTO AI DISEGNI ARCHITETTONICI.
GENERAL SHEET NOTES:
NOTE GENERALI DEL DISEGNO :
4 4
54 4
A A
E E
P R
O S
P E
T T
I S U
A S
S I A
E D
E
A A
N
EAVE TOS
FIRST FLOOR
RIDGE TOS
ABCDE
DOOR
L.C.
-1500
8660 8660 8660 8660
1340 2650 2650 2650 2650 134026502650 2650 2650
V A
R
SK563
A1
2600 26002650
SK565
B1
350 350
GRONDA TOS
LIV. PORTE
PRIMO PIANO
FOND.
MAGRONE
COLMO TOS
FOUND
-1000
EAVE TOS
FIRST FLOOR
RIDGE TOS
A B C D E
DOOR
L.C.
-1500
8660 8660 8660 8660
1340 1400
2620 2620 2620
2140 1110 2140 1985 1985 2140
2200 2200 2200
2140 13402200
V A
R
350350
GRONDA TOS
LIV. PORTE
PRIMO PIANO
FOND.
MAGRONE
COLMO TOS
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
1 : 100
/1
/2
:2
:1
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
E
LE
V A
T
IO
N O
N A
X
IS
SB202A
PD AA ES
S B
2A
E
LE
V A
T
IO
N O
N A
X
IS
14121465 51 429
1 : 100SB101A
ELEVATION ON AXIS
C1 PROSPETTO SU ASSE
1 : 100SB101A
ELEVATION ON AXIS
B1 PROSPETTO SU ASSE
KEY #
KEYED NOTES / NOTE CHIAVE
ENGLISH NOTE NOTA ITALIANA
1 COLUMN HEB320 COLONNA HEB320
2 BEAM IPE400 TRAVE IPE400
3 COLUMN IPE160 COLONNA IPE160
4 GIRT UPN 200 ARCARECCIO UPN200
5 SHS 150x16 TRAVE TUBOLARE 150x16
1 0 1 2 3 4 5 6 7 8 9
1:100
3 54
1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001A AND
S002A.
PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO
ALLE TAVOLE S001A E S002A.
2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO
ARCHITECTURAL DRAWINGS.
PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE
RIFERIMENTO AI DISEGNI ARCHITETTONICI.
GENERAL SHEET NOTES:
NOTE GENERALI DEL DISEGNO :
P R
O S
P E
T T
I S U
A S
S I 1
E
A
N
C1
SB202A
B1
SB202A
A1
SB201A
1 2 3 4 5 6 7 8 9
A
B
C
D
E
8500 8000 8000 8000 8000 8000 8000 8500
65000
SF401A
C1
SF102A
A1
SF103A
A1
5 0 5 10 15
1:200
KEY PLAN
PIANTA DI RIFERIMENTO
BA
NORD DELLA PIANTA
PLAN NORTH
1 : 200
OVERALL ROOF FRAMING PLAN
C1 CARPENTERIA GENERALE DELLA COPERTURA
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
1 : 200
/1
/2
:2
:2
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
O V
E R
A
LL
R O
O F
F R
A M
IN
G
P
LA
N
SF101A
PD AA ES
S F
1A
O V
E R
A
LL
R O
O F
F R
A M
IN
G
P
LA
N
14121466 52 429
1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001A AND S002A.
PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO ALLE
TAVOLE S001A E S002A.
2. COORDINATE ROOF PENETRATIONS WITH ARCHITECTURAL DRAWINGS AND
DETAIL D3 ON SHEET SK556.
COORDINARE LE FOROMETRIE IN COPERTURA CON I GRAFICI ARCHITETTONICI E
IL PARTICOLARE D3 SUL DISEGNO SK556.
GENERAL SHEET NOTES:
NOTE GENERALI DEL DISEGNO :
C A
R P
E N
T E
R
IA
G E
N E
R A
L E
D E
L L
A C
O P
E R
T U
R
1 2 3 4 5
B
C
D
E
8500 8000 8000 8000
3 3
M
A T
C H
LI
N
E
S E
E A
O
N S
H E
E T
S F
3A
SK558
A3
SK558
C3
SK558
A1
SK558
C1
SK558
A4
LI
N
E A
D I C
O
LL
E G
A M
E N
T O
V
E D
I A
U
T A
V . S
F
3A
SK568
D3
D3
SK556
KEY PLAN
PIANTA DI RIFERIMENTO
BA
1 0 1 2 3 4 5 6 7 8 9
1:100
NORD DELLA PIANTA
PLAN NORTH
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
1 : 100
/1
/2
:2
:2
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
R O
O F
F R
A M
IN
G
P
LA
N
A R
E A
A
SF102A
PD AA ES
S F
2A
R O
O F
F R
A M
IN
G
P
LA
N
A R
E A
A
14121467 53 429
1 : 100SF101A
ROOF FRAMING PLAN - AREA A
A1 CARPENTERIA COPERTURA - AREA A
KEY #
KEYED NOTES / NOTE CHIAVE
ENGLISH NOTE NOTA ITALIANA
1 COLUMN HEB320 COLONNA HEB320
2 BEAM IPE400 TRAVE IPE400
3 BEAM HEB220 TRAVE HEB220
4 ANGLE L 150x12 CONTROVENTO L 150x12
5 ANGLE L 100x10 CONTROVENTO L 100x10
C A
R P
E N
T E
R
IA
C O
P E
R T
U R
A
A R
E A
A
1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001A AND S002A.
PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO ALLE
TAVOLE S001A E S002A.
2. COORDINATE ROOF PENETRATIONS WITH ARCHITECTURAL DRAWINGS AND
DETAIL D3 ON SHEET SK556.
COORDINARE LE FOROMETRIE IN COPERTURA CON I GRAFICI ARCHITETTONICI E
IL PARTICOLARE D3 SUL DISEGNO SK556.
GENERAL SHEET NOTES:
NOTE GENERALI DEL DISEGNO :
5 6 7 8 9
A1
SF301A
A1
SF301A
A
B
C
D
E
8000 8000 8000 8500
M A
T C
H
LIN
E
S E
E A
1 O N
S H
E E
T S
F 102A
SK556
A1 SK557
C1
SK556
C1
LIN
E
A D
I C O
LLE
G
A M
E N
T O
V
E D
I A
S U
T A
V . S
F 102A
1 0 1 2 3 4 5 6 7 8 9
1:100
KEY PLAN
PIANTA DI RIFERIMENTO
BA
NORD DELLA PIANTA
PLAN NORTH
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
1 : 100
/1
/2
:2
:3
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
R O
O F
F R
A M
IN
G
P
LA
N
A R
E A
B
SF103A
PD AA ES
S F
3A
R O
O F
F R
A M
IN
G
P
LA
N
A R
E A
B
14121468 54 429
1 : 100SF101A
ROOF FRAMING PLAN - AREA B
A1 CARPENTERIA COPERTURA - AREA B
KEY #
KEYED NOTES / NOTE CHIAVE
ENGLISH NOTE NOTA ITALIANA
1 COLUMN HEB320 COLONNA HEB320
2 BEAM IPE400 TRAVE IPE400
3 BEAM HEB220 TRAVE HEB220
4 ANGLE L 150x12 CONTROVENTO L 150x12
5 ANGLE L 100x10 CONTROVENTO L 100x10
C A
R P
E N
T E
R
IA
C O
P E
R T
U R
A
A R
E A
B
1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001A AND S002A.
PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO ALLE
TAVOLE S001A E S002A.
2. COORDINATE ROOF PENETRATIONS WITH ARCHITECTURAL DRAWINGS AND
DETAIL D3 ON SHEET SK556.
COORDINARE LE FOROMETRIE IN COPERTURA CON I GRAFICI ARCHITETTONICI E
IL PARTICOLARE D3 SUL DISEGNO SK556.
D
C
A
B
3 4 5 9876
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B B B B B B D D B B B B B BD D
B B B B B B D D B B B B B BD D
A
A
A
A
A
A
A
A
D D
D D
D D
B B B B B BD B B B B B B D
E E E E E ED E E E E E E D
E E E E E ED E E E E E E D
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
1 2 3 4 5 6 7 8 9
8500 8000 8000 8000 8000 8000 8000 8500
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
1 : 200
/1
/2
:2
:3
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
S T
R U
C T
U R
A L
S C
H E
M E
SF104A
PD AA ES
S F
4A
S T
R U
C T
U R
A L
S C
H E
M E
14121469 55 429
5 0 5 10 15
1:200
NORD DELLA PIANTA
PLAN NORTH
1 : 200
STRUCTURAL SCHEME
C1 SCHEMA STRUTTURALE
1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001A AND
S002A.
PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO
ALLE TAVOLE S001A E S002A.
STRUCTURAL CONNECTIONS / CONNESSIONI STRUTTURALI
JOINT / NODO TYPE / TIPOLOGIA
CONNECTED MEMBERS / ELEMENTI
COLLEGATI
N. BOLTS SUPPORTING PROFILE / N. BULLONI
PORTANTE
N. BOLTS SUPPORTED PROFILE / N. BULLONI
PORTATO
A FIXED / INCASTRO BEAM IPE 400 / COL HEB320 14
B FIXED / INCASTRO BEAM HEB220 / COL HEB 320 8
C PINNED / CERNIERA BEAM IPE 400 / COL HEB320 8 4
D PINNED / CERNIERA BEAM HEB220 / COL HEB 320 6 3
E PINNED / CERNIERA BEAM HEB220 / COL HEB 320 6 3
KEY #
KEYED NOTES / NOTE CHIAVE
ENGLISH NOTE NOTA ITALIANA
1 CONNECTION JOINT A. SEE
DETAIL C1 ON SHEET SK559
CONNESSIONE NODO A. VEDI
DETTAGLIO C1 ALLA TAVOLA SK559
2 CONNECTION JOINT B. SEE
DETAIL A1 ON SHEET SK559
CONNESSIONE NODO B. VEDI
DETTAGLIO A1 ALLA TAVOLA SK559
3 CONNECTION JOINT C. SEE
DETAIL C1 ON SHEET SK560
CONNESSIONE NODO C. VEDI
DETTAGLIO C1 ALLA TAVOLA SK560
4 CONNECTION JOINT D. SEE
DETAIL D3 ON SHEET SK560
CONNESSIONE NODO D. VEDI
DETTAGLIO D3 ALLA TAVOLA SK560
5 CONNECTION JOINT E. SEE
DETAIL B1 ON SHEET SK560
CONNESSIONE NODO E. VEDI
DETTAGLIO B1 ALLA TAVOLA SK560
S C
H E
M A
S T
R U
T T
U R
A L
E
1 : 200
B1 SCHEMA STATICO LAMIERA COPERTURA
ROOF DECK SPAN SCHEME
KEY PLAN
PIANTA DI RIFERIMENTO
BA
EAVE TOS
FIRST FLOOR
RIDGE TOS
A B C D E
16001600
8660866086608660
DOOR
7710 300 300
7710 7710 7710 1600
1 9
6 7 8
L.C.
-1500
GRONDA TOS
LIV. PORTE
PRIMO PIANO
FOND.
MAGRONE
COLMO TOS
FOUND
-1000
EAVE TOS
FIRST FLOOR
RIDGE TOS
ABCDE
DOOR
8660 8660 8660 8660
34640
C1
SF301A
C1
SF301A
1 9
6 7 8
1600 7710 1600
L.C.
-1500
300 1500 900 1900 900 2510 1600 2270 900 3100 900
300 7710
GRONDA TOS
LIV. PORTE
PRIMO PIANO
FOND.
MAGRONE
COLMO TOS
FOUND
-1000
EAVE TOS
1 2 3 4 5 6 7 8 9
FIRST FLOOR
RIDGE TOS
A1
SF301A
A1
SF301A
B1
SF301A
B1
SF301A
DOOR
300 7700 300 7700 300 7050 1600 7050 300 7700 300 7700 300 7100 250014002500
8500 8000 8000 8000 8000 8000 8000 8500
10 11
6 7 8
21 5
L.C.
-1500
900 3800 900
GRONDA TOS
LIV. PORTE
PRIMO PIANO
FOND.
MAGRONE
COLMO TOS
SEZIONE
1 : 100SB103A A1
SECTION
SEZIONE
1 : 100SB102A B1
SECTION
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 10 MARCH 2009
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
T
V
Y
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
A
T L A
N T
IC
N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M C
O M
M A
N D
N O
R F
O L
K V
A
A V
IA
N
O A
IR
B
A S
E A
V
IA
N O
IT
A L Y
P -0
E D
I- R
A D
R S
T O
R A
G E
F A
C
IL
IT
Y
DESIGN DIRECTOR
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE: 04 AUGUST 2022
RICHARD STEPHENS, PE
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
FIRE PROTECTION
LET/LRP
A T
L A
N T
IC
D
E S
IG
N
A N
D C
O N
S T
R U
C T
IO
N
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
P
LO
T T
E D
N6247022R3000
DPS
A
B
C
D
Approved by Allan Lucht, via Email.
JTV
1 : 100
/1
/2
:2
:4
E
L a v o ri \2
\0
-R
A D
R A v ia n o \F in a l p e r fi rm e \B
L D
G C
R -1
-S
.r v t
S E
C T
IO
N
S
SF301A
PD AA ES
S F
1A
S E
C T
IO
N
S
14121470 56 429
SEZIONE
1 : 100SB102A C1
SECTION
1 0 1 2 3 4 5 6 7 8 9
1:100
KEY #
KEYED NOTES / NOTE CHIAVE
ENGLISH NOTE NOTA ITALIANA
1 COLUMN HEB320 COLONNA HEB320
2 BEAM HEB220 TRAVE HEB220
3 BEAM IPE400 TRAVE IPE400
4 ANGLE L 150x12 CONTROVENTO L 150x12
5 ANGLE L 100x10 CONTROVENTO L 100x10
6 R.C. SLAB THICK. 220 mm SOLETTA IN C.A. SPESSORE 220 mm
7 R.C. FOOTING FONDAZIONE IN C.A.
8 STEEL PLATE PIASTRA IN ACCIAIO
9 R.C. INTERNAL WALL (h=2200 mm) MURO INTERNO IN C.A. (h=2200 mm)
10 R.C. EXTERNAL WALL (h=1220 mm) MURO ESTERNO IN C.A. (h=1220 mm)
11 BOLLARD DISSUASORE
12 R.C. WALLS THICK. 200 mm MURO IN C.A. SPESSORE 200 mm
13 REMOVABLE BOLLARD DISSUASORE RIMOVIBILE
1. FOR SPECIFICATION AND MATERIAL'S PROPERTIES SEE SHEET S001A AND
S002A.
PER LE SPECIFICHE E LE PROPRIETA' DEI MATERIALI, FARE RIFERIMENTO
ALLE TAVOLE S001A E S002A.
2. FOR CONCRETE WALLS AND BOLLARDS LOCATION REFER TO
ARCHITECTURAL DRAWINGS.
PER IL POSIZIONAMENTO DEI MURI IN C.A. E DEI DISSUASORI, FARE
RIFERIMENTO AI DISEGNI ARCHITETTONICI.
GENERAL SHEET NOTES:
NOTE GENERALI DEL DISEGNO :
S E
Z
IO
C
A1
SF401A
A1
SF401A
A3
SF401A
A3
SF401A
C3
SK551
C3
SK551
b.1 b.2 b.A b.B b.C b.D b.E
3800 900
1100 1900 1100 400
FOUND
-1000
EAVE TOS
FIRST FLOOR
C
DOOR
4000 4080 3200
L.C.
-1500 b.A b.B b.C b.D b.E
900 3100 900 2270 1600 2510 900 1900 900
GRONDA TOS
LIV. PORTE
PRIMO PIANO
FOND.
MAGRONE
FOUND
-1000
EAVE TOS
FIRST FLOOR
DOOR
2500 1400 900
L.C.
-1500 b.1 b.2
9003800
GRONDA TOS
LIV. PORTE
PRIMO PIANO
FOND.
MAGRONE
C 14
C1
SR303A
C1
SR303A
A1
SR303A
A1
SR303A
C2
SR303A
C2
SR303A
A2
SR303A
A2
SR303A
SK553
A3
SK553
A4
A4
SR303A
A4
SR303A
C4
SR303A
C4
SR303A
b.1 b.2 b.A b.B b.C b.D b.E
3100 4700280
1900 400
1100 1100
SERVICE BUILDING FOUNDATION PLAN
1 : 100SB101A C3 PIANTA FONDAZIONI LOCALI DI SERVIZIO
SEZIONE
1 : 100SF401A A1
SECTION
SEZIONE
1 : 100SF401A A3
SECTION
DOTT. ING.
DI STEFANO PIETRO
ISCRITTO ALL'ALBO
PROFESSIONALE
COL N. 13921
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
S…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .