Attachment S - Revised Drawing CU101A.pdf
PDF 1017 KB Posted
- Solicitation number
- N6247022R3000
About this file
This drawing package pertains to a federal contract solicitation to construct Rapid Airfield Damage Recovery Storage Facilities at Aviano Air Base in Italy. The project involves installing new utility lines including a potable water line tied to an existing main 400 meters southwest, a sanitary sewer service line tied to an existing sewer main with a minimum invert of 159.00 at the building, a storm sewer discharge line to a drainage field, and related appurtenances. The drawings provide existing conditions and utility information, notes regarding field verifications, and specifications for fire hydrants, manholes, cleanouts, and joining methods. The solicitation was issued by the Department of the Navy Naval Facilities Engineering Command for contract number N6247022R3000 and involves planning and design work to support rapid runway repair capabilities at the Air Base in Italy.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R4
R5
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
SAN
SAN
SAN
SAN
SAN
SAN
SAN
S
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
W W
W W
W W
W
W
W
W
W
W
EW
EW
EW
EW
EW
EW
EW
EW
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
ES
AN
ES
AN
ES
AN
ES
AN
ESAN
ESAN
ESAN
ESAN
ESAN
ESAN
EXIST SEWER M.H.
RIM=±159.61
FL=±156.74
W. FL=156.41
N.E. FL=156.48
E. FL=156.45
EXIST SEWER M.H.
RIM=±159.26
FL=±157.23
W. FL=157.02
N.E. FL=157.03
S. FL=157.01
EXIST SEWER M.H.
RIM=±160.95
FL=±158.91
S.W. FL=158.52
N.E. FL=158.55
EXIST SEWER M.H.
RIM=±159.62
FL=±157.46
N. FL=157.22
S.W. FL=157.19
DISCLAIMER
UPON ACCEPTANCE OF THESE PLANS FOR CONSTRUCTION, THE CONTRACTOR AGREES TO FAMILIARIZE HIMSELF WITH THE PROJECT AND VERIFY THE LOCATION AND CORRECTNESS OF ANY AND ALL APPURTENANCES, RIGHT-OF-WAY, PROPERTY LINES, ELEVATIONS, OBSTRUCTIONS, HAZARDS, OR CONFLICTS THAT MAY EXIST UPON EXAMINATION OF CURRENT FIELD CONDITIONS. DESIGN OF THESE PLANS WAS BASED UPON AVAILABLE INFORMATION AND INTERPRETATION OF AVAILABLE DATA, ANY DISCREPANCIES DISCOVERED, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD FOR EVALUATION, THE CONTRACTOR SHALL ACCEPT ALL LIABILITY AND RISKS FOR CONSTRUCTION PROCEEDING PRIOR TO ENGINEERS EVALUATION.
ESCLUSIONE DI RESPONSABILITÀ
DOPO L'ACCETTAZIONE DI QUESTI PIANI DI COSTRUZIONE, L'APPALTATORE ACCETTA DI FAMILIARIZZARE SE STESSO CON IL PROGETTO E DI VERIFICARE LA POSIZIONE E LA CORRETTEZZA DI QUALSIASI ATTREZZATURA, DIRITTO DI PASSAGGIO, LINEE DI PROPRIETÀ, ALTEVAZIONI, OSTACOLI, PERICOLI O CONFLITTI ESAME DELLE CONDIZIONI DI CAMPO ATTUALI. LA PROGETTAZIONE DI QUESTI PIANI È STATA BASATA SULLE INFORMAZIONI DISPONIBILI E SULL'INTERPRETAZIONE DEI DATI DISPONIBILI, QUALSIASI DISCREPANZA RILEVATA, DEVE ESSERE PORTATA IMMEDIATAMENTE ALL'ATTENZIONE DELL'INGEGNERE DEL RECORD PER LA VALUTAZIONE, IL FORNITORE ACCETTA TUTTE LE RESPONSABILITÀ EI RISCHI PER IL PROCEDIMENTO DI PRECISIONE DELLA COSTRUZIONE.
SI
TE
U
TI
LI
TY
P
LA
N
CU101A
IS
O C
ONTAINERS
CONTENITORE 25
IS
O
EXISTING PAVEMENT
PAVIMENTAZIONE ESISTENTE
Meters 1:400
20100 5
NO. COORDINATES ELEVATION
5100595,685 313884,514 160,069 N E
SITE 1 (R4)
5100686,617 313991,057 161,531SITE 1 (R5)
EXISTING CONDITIONS, TOPOGRAPHY, AND UTILITY
SURVEY PROVIDED BY:
CSG PALLADIO
STRADIA SAVIAONA
278/1-36100 VICENZA
TEL ++39/0444 304091
FAX ++39/0444 313136
DATE OF SURVEY : JULY 2021
CONTROL POINT SUMMARY TABLE
( BENCHMARK: UTM 33N BASE UNITS METERS)
TABELLA DI RIEPILOGO DEI PUNTI DI RIFERIMENTO
CAPISALDI: UTM 33N BASE UNITA' IN METRI
COORDINATE QUOTE ALTIMETRICHENR.
RILIEVO DELLE CONDIZIONI ESISTENTI,
TOPOGRAFICO E DEI SOTTOSERVIZI
FORNITO DA CSG PALLADIO
DATA RILIEVI : JULY 2021 SI
TO
PI
AN
TA
D
EI
S
OT
TO
SE
RV
IZ
I
SITE 1 RADR
STORAGE FACILITY
1 CRATER REPAIR KIT +
1 FOD REMOVAL KIT/
FFE = 161.01
SITO 1 RADR
MAGAZZINO
1 KIT RIPARAZIONE
CRATERI + 1 KIT DI
RIMOZIONE DETRITI
CORPI ESTRANEI /
ALTEZZA S.L.M. = 161.01
DRAINAGE FIELD
CAMPO DI D
RENAGGIO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
1 2 3 4 5
1 2 3 4 5
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D
EP
AR
TM
EN
T
O F
T H
E N
AV
Y
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
AT
LA
NT
IC
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
N O
R
FO
LK
, V
A
AV
IA
NO
A
IR
B
AS
E
AV
IA
NO
, I
TA
LY
P-
ED
I-R
AD
R
ST
O
RA
G E
FA
CI
LI
TY
DES DRW CHK
SATISFACTORY TO DATE : 04 AUGUST 2022
225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com
A
B
C
D
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
SI
FI
ED
A
B
C
D
JMW
DESIGN MANAGER:
BRANCH MANAGER:
PM/DM:
FIRE PROTECTION:
RICHARD STEPHENS, PE
LET/LRP
DPS
FI
LE
N
AM
E:
T
:\A ct iv e
Pr oj ec ts
\2
1\ (1
) A vi an o
Ai r F or ce
B as e\ D ra w in gs
\W or ki ng
C
AD
D ra w in gs \A
VI
AN
O P
LA
N
S
ET
.d w g L
AY
O
U T
N
AM
E:
C
U
1A P
LO
TT
ED
: T ue sd ay , M ar ch
7,
- 4
:5 7p m U
SE
R
: T ra na
NAVFAC METRIC DRAWFORM REVISION: 07 AUGUST 2018
1659896
AT
LA
N
TI
C D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
Approved by Allan Lucht, via Email.
N6247022R3000
DES: MD DRW: CHK: JM
99026
MARGARET L. DUBBIN
N
FIRE HYDRANT WITH APPURTENANCES
DRAINAGE FIELD (SEE CG101A)
EXISTING SOIL VAPOR TEST VAULT (SEE
CD101A)
MECHANICAL JOINTS ON WATERLINE
EXISTING SANITARY SEWER MANHOLE
TRENCH DRAIN
TIE POTABLE WATER LINE TO EXISTING
WATER MAIN, ASSUMED 400M SOUTHWEST.
FIELD VERIFY TIE IN LOCATION
DOUBLE SANITARY SEWER CLEANOUT ON
SANITARY SERVICE LINE (SEE CK552)
FIELD VERIFY DEPTH AND LOCATION OF
EXISTING SEWER LINE, TIE SANITARY
SEWER SERVICE LINE TO EXISTING
SANITARY SEWER MAIN
Ø100 SANITARY SEWER SERVICE LINE
MIN. INV. 159.00 AT BLDG. PER MECHANICAL
Ø250 POTABLE WATER LINE
Ø400 STORM SEWER DISCHARGE TO
DRAINAGE FIELD
Ø50 POTABLE WATER SERVICE LINE
Ø200 TIE FIRE PROTECTION LEAD-IN TO
POTABLE WATER LINE
Ø300 STORM SEWER. BUILDING DRAIN AND
TRENCH DRAIN COLLECTORS
POZZO DI ESTRAZIONE ESISTENTE
INSTALLARE IDRANTE ANTINCENDIO E
RELATIVI ACCESSORI
AREA DI DRENAGGIO (VEDERE PIANTE
LIVELLAMENTO E DRENAGGIO
SEPARATORE DI OLII / ACQUA
POZZETTO ESISTENTE (FOGNATURA)
CANALE DI DRENAGGIO
INSTALLARE DOPPIO POZZETTO
FOGNARIO DI ISPEZIONE SULLA NUOVA
LINEA FOGNARIA (VEDERE TAVOLA DI
DETTAGLIO
FOGNA TEMPESTA Ø300. COLLETTORI DI
SCARICO E DI SCARICO DI TRINCEE PER EDIFICI
INSTALLARE NUOVA LINEA DI SCARICO Ø400
ALL'AREA DI DRENAGGIO
LINEA DI SERVIZIO FOGNARIO SANITARIO Ø100
MINIMO 159,00 A BLDG. PER MECCANICO
LINEA DELL'ACQUA POTABILE Ø50
OIL WATER SEPARATOR
CAMERA ESISTENTE PER MONITORAGGIO DEI
VAPORI DEL SUOLO
INSTALLARE GIUNTI MECCANICI PER LA NUOVA
LINEA DELL'ACQUA
ALLACCIARE LA NUOVA LINEA DI ACQUA POTABILE
ALLA LINEA ESISTENTE PRINCIPALE A CIRCA 400M
A SUD-OVEST. VERIFICARE SUL POSTO IL PUNTO DI
ALLACCIO
VERIFICARE IN SITO LA PROFONDITA' E
POSIZIONE DELLA FOGNATURA ESISTENTE,
COLLEGARE LA NUOVA LINEA FOGNARIA A
QUELLA ESISTENTE
INSTALLARE NUOVA LINEA DELL'ACQUA POTABILE
Ø200 TIE PROTEZIONE ANTINCENDIO
LEAD-IN ALLA LINEA DI ACQUA POTABILE
SITE 1 UTILITY PLAN
SITO 1 PIANTA DEI SOTTOSERVIZI
14121448
HVAC UNITS, SEE ELECTRICAL AND
MECHANICAL PLANS18
UNITÀ HVAC, VEDI PIANI ELETTRICI E
MECCANICI
AutoCAD SHX Text O/W
AutoCAD SHX Text 1 : 400
AutoCAD SHX Text ATRan
AutoCAD SHX Text
KEY #
AutoCAD SHX Text
ENGLISH NOTE
AutoCAD SHX Text
NOTA/ITALIANA
AutoCAD SHX Text
KEYED NOTES
AutoCAD SHX Text
EXISTING EXTRACTION WELL
AutoCAD SHX Text A4
AutoCAD SHX Text
AutoCAD SHX Text
REVISED ITALIAN TRANSLATION OF KEYNOTES 13 , 15 , 16 , AND 18
AutoCAD SHX Text
08 MARCH 2023
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| Sheets and Views |
| CU101A |
File details come from the government source that posted it. Updated .