Attachment H 1659896dwgVOL1_1of3.pdf

PDF 25 MB Posted

Attached to
P-002 EDI: Rapid Airfield Damage Recovery Storage Facilities, Aviano Air Base, Italy
Solicitation number
N6247022R3000
Issued by

About this file

This document provides details on a federal solicitation for construction services. The solicitation number is N6247022R3000 and is being issued by the Department of the Navy Naval Facilities Engineering Command for Rapid Airfield Damage Recovery Storage Facilities at Aviano Air Base in Italy. The solicitation seeks offers for the construction of storage facilities to support rapid repair of airfield damage. Offerors should respond in accordance with the requirements and instructions outlined in the solicitation. The anticipated award date was not specified.

View the file

Other files

File Type Posted
Amendment 0009.pdf PDF
Amendment 0008.pdf PDF
Amendment 0007.pdf PDF
Attachment S - Revised Drawing CU101A.pdf PDF
Attachment O - Site Visit Sign In.pdf PDF
Attachment T - Revised Drawing CU101B.pdf PDF
Attachment R - Revised Drawing CS102B.pdf PDF
Attachment U - Revised Specification 01 50 00.pdf PDF
Amendment 0006.pdf PDF
Attachment P - Site 2 Access Road Aerial.pdf PDF
Attachment Q - Revised Drawing CD101A.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0003.pdf PDF
Attachment N - Gas Line Trench Detail.pdf PDF
Amendment 0002.pdf PDF
Attachment M - Installation Access Request Form.pdf PDF
Amendment 0001.pdf PDF
Attachment L - Installation Access Request Checklist.pdf PDF
Attachment E - Price Proposal Form.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
Attachment K - Italian Safety Plan_Combined.pdf PDF
Attachment H 1659896dwgVOL1_3of3.pdf PDF
Attachment H 1659896dwgVOL1_2of3.pdf PDF
Attachment C - Construction Experience Project Data Sheet.pdf PDF
Attachment G - Specifications.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment H 1659896dwgVOL2_1of4.pdf PDF
Attachment H 1659896dwgVOL2_3of4.pdf PDF
Attachment A - Pre-Proposal Inquiry Form.xls XLS spreadsheet
Attachment H 1659896dwgVOL2_2of4.pdf PDF
Attachment I - HAZMAT Report Summary.pdf PDF
Attachment J - Host Nation Code Compliance Certification.pdf PDF
N62470-22-R-3000.pdf PDF
Attachment H 1659896dwgVOL2_4of4.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MAPPA LOCALIZZAZIONE MAPPA LOCALIZZAZIONE MAPPA LOCALIZZAZIONE

T

IT

O L O

D E

L L A

T A

V O

L A

E

L O

C A

L

IZ

Z A

Z

IO

N E

NN N

NTS

VICINITY MAP

NTS

LOCATION MAP

NTS

LOCAL AREA MAP PROJECT LOCATION

NAVAL FACILITIES EUROPE, AFRICA, CENTRAL

P-002 EDI-RADR STORAGE

FINAL (100%) DESIGN SUBMITTAL

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

DATE: 10 OCTOBER 2022 AVIANO, ITALYSOLICITATION NO: N6247022R3000

SITE 1 - HEAVY REPAIR YARD SITE FACILITY

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N

O

F

H

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

NO SCALE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

KMS

/1

/2

:0 :1

A

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \D

R A

W

IN

G

IN

D E

X C

O M

P O

S

IT

E B

L D

C R b g ro th e .r v t

T

IT

LE

S

H E

E T

A N

D L

O C

A T

IO

N

M A

P S

GI001

BKG BKG BAG

G I0

T

IT

LE

S H

E E

T A

N D

L O

C A

T

IO

N M

A P

S

14121415 1 429

HAVING PARTICIPATED IN THE DESIGN OF PROJECT No. 1659896

P-002 EDI-RADR STORAGE FACILITY, AVIANO AB, ITALY AND

HAVING THOROUGHLY REVIEWED THE COMPLETED PROJECT

DOCUMENTS, I DECLARE THAT THE FACILITY DESIGN INCLUDED

HEREIN COMPLIES WITH ALL APPLICABLE ITALIAN CODES AND

LAWS.

AVENDO PARTECIPATO ALLO SVILUPPO DEL PROGETTO N.

1659896, P-002 EDI-RADR STORAGE, AVIANO AB, ITALIA, E AVENDO

ESAMINATO ATTENTAMENTE LA DOCUMENTAZIONE DI PROGETTO

PRODOTTA, DICHIARO CHE IL PROGETTO ALLEGATO È

CONFORME A TUTTE LE NORME E LEGGI ITALIANE APPLICABILI.

DATE SIGNATUREDATA FIRMA TIMBRO PROFESSIONALE

27 JULY 2022 27 JULY 2022

10/10/2022

IN

D

IC

E

D I D

IS

E

G N

O

TITOLO DELLA TAVOLA E LOCALIZZAZIONE

INDICE DI DISEGNI

GENERALE E LEGENDA DEL SITO

ABBREVIAZIONI - PAGINA 1

ABBREVIAZIONI - PAGINA 2

ABBREVIAZIONI - PAGINA 3

ABBREVIAZIONI - PAGINA 4

ABBREVIAZIONI - PAGINA 5

ABBREVIAZIONI - PAGINA 6

NARRATIVA DEL CODICE DI SICUREZZA

PIANO DI CLASSIFICAZIONE DELL'OCCUPAZIONE PER LA SICUREZZA

PLANIMETRIA SICUREZZA - AREA "A"

PLANIMETRIA SICUREZZA - AREA "B"

NARRATIVA DEL CODICE DI SICUREZZA

NARRATIVA DEL CODICE DI SICUREZZA

NARRATIVA DEL CODICE DI SICUREZZA

NARRATIVA DEL CODICE DI SICUREZZA

CONFORMITA' AL CODICE PIANTA DEL SITO

PLANIMETRIA STATO DEI LUOGHI E DEMOLIZIONI

PLANIMETRIA E PIANTUMAZIONI DI PROGETTO

TABELLA E DETTAGLI PIANTUMAZIONI

NOTE GENERALI 1/2

NOTE GENERALI 2/2

PIANTA GENERALE DELLE FONDAZIONI

PIANTA FONDAZIONI - AREA A

PIANTA FONDAZIONI - AREA B

PIANTA DELLA SOLETTA A TERRA

PROSPETTI SU ASSI A ED E

PROSPETTI SU ASSI 1 E 9

CARPENTERIA GENERALE DELLA COPERTURA

CARPENTERIA COPERTURA - AREA A

CARPENTERIA COPERTURA - AREA B

SCHEMA STRUTTURALE

SEZIONI

PIANTE E SEZIONI AREA SERVIZI

ARMATURE FONDAZIONI 1/2

ARMATURE FONDAZIONI 2/2

COLLEGAMENTI ACCIAIO 1/3

COLLEGAMENTI ACCIAIO 2/3

COLLEGAMENTI ACCIAIO 3/3

PARTICOLARI COLLEGAMENTI 1/2

PARTICOLARI COLLEGAMENTI 2/2

PARTICOLARI TELAI FACCIATA 1/3

PARTICOLARI TELAI FACCIATA 2/3

PARTICOLARI TIPICI DI ARMATURA IN FONDAZIONE

PARTICOLARI SOLETTA A TERRA

PARTICOLARI TIPICI VARI DI ARMATURA

PARTICOLARI TIPICI PERIMETRALI

PARTICOLARE PIASTRA DI COLLEGAMENTO COLONNE

ARMATURA DELLE PARETI AREA SERVIZI

ARMATURA DELLA SOLETTA A TERRA AREA SERVIZI

PARTICOLARI TELAI FACCIATA 3/3

COLLEGAMENTO DI BASE TELAI FACCIATA

COLLEGAMENTI TELAI DI FACCIATA 1/2

COLLEGAMENTI TELAI DI FACCIATA 2/2

PARTICOLARI TIPICI VARI

PIANTA GLOBALE PIANO TERRA

PIANTA PIANO TERRA - AREA 'A'

PIANTA FINITURE E TABELLA

PIANTA RIFLESSA SOFFITTI - AREA A

PIANTA DEL TETTO

PIANTA BARRIERA ALL'ARIA E SEZIONI

PROSPETTI ESTERNI

PROSPETTI ESTERNI

SEZIONI EDIFICIO

PIANTA INGRANDITA - SERVIZIO IGIENICO

TABELLA PORTE

PIANTA PIANO TERRA - AREA 'B'

PIANTA RIFLESSA SOFFITTI - AREA B

SEZIONI PARETI

TIPI PARETI INTERNE

PARTICOLARI PARETI ESTERNE

PARTICOLARI TETTO

PARTICOLARI APERTURE

PARTICOLARI VARI

PARTICOLARI SEGNALETICA

PARTICOLARI PARETI ESTERNE

ALLARME INCENDIO NOTE GENERALI, LEGENDA E

SCHEMI

PIANO UDIBILITA' ANTINCENDIO

PIANTA ALLARME INCENDIO - AREA "A"

NOTE GENERALI ESTINZIONE INCENDI

PIANTA DI CLASSIFICAZIONE DEL RISCHIO DI

ESTINZIONE INCENDI

PIANTA ALLARME INCENDIO - AREA "B"

SEZIONI ESTINZIONE INCENDI

LEGENDA DIAGRAMMA TUBAZIONI E STRUMENTAZIONE

AREA RIPARAZIONI MEZZI PESANTI PIANTA COMPLESSIVA IMPIANTO IDRICO

AREA MEZZI PESANTI INGRANDIMENTO IMPIANTO IDRICO

AREA MEZZI PESANTI PARTICOLARI IMPIANTO IDRICO - TAVOLA 1

AREA MEZZI PESANTI PARTICOLARI IMPIANTO IDRICO - FOGLIO 2

HEAVY - TABELLE APPARECCHIATURE IMPIANTO IDRICO

AREA MEZZI PESANTI SCHEMI ISOMETRICI IMPIANTO IDRICO

PARTICOLARI MECCANICI - TAVOLA 1

HEAVY REPAIR - PIANTA DI ZONA HVAC

HEAVY REPAIR - PANTA TUBAZIONI HVAC

HEAVY REPAIR - PIANTA CANALI

HEAVY REPAIR - PIANTA INGRANDITA CENTRALE TERMICA

PARTICOLARI MECCANICI - TAVOLA 2

PARTICOLARI MECCANICI - TAVOLA 3

PARTICOLARI MECCANICI - TAVOLA 4

PARTICOLARI MECCANICI - TAVOLA 5

PARTICOLARI MECCANICI - TAVOLA 6

PARTICOLARI MECCANICI - TAVOLA 7

PARTICOLARI MECCANICI - TAVOLA 8

PARTICOLARI MECCANICI - TAVOLA 9

PARTICOLARI MECCANICI - TAVOLA 10

PARTICOLARI MECCANICI - TAVOLA 11

PARTICOLARI MECCANICI - TAVOLA 12

LEGGENDA HVAC MECCANICA

HEAVY REPAIR TABELLE MECCANICHE TAVOLA 1

HEAVY REPAIR TABELLE MECCANICHE TAVOLA 2

HEAVY REPAIR TABELLE MECCANICHE TAVOLA 3

HEAVY REPAIR TABELLE MECCANICHE TAVOLA 4

HEAVY REPAIR TABELLE MECCANICHE TAVOLA 5

HEAVY REPAIR TABELLE MECCANICHE TAVOLA 6

HEAVY REPAIR TABELLE MECCANICHE TAVOLA 7

DIAGRAMMA SCHEMATICO DI CONTROLLO UNITA' DI

TRATTAMENTO ARIA E SEQUENZE OPERATIVE

DIAGRAMMA SCHEMATICO DI CONTROLLO UNITA' DI

TRATTAMENTO ARIA E SEQUENZE OPERATIVE

SCHEMA DI CONTROLLO SISTEMA DI RISCALDAMENTO E

SEQUENZA DI CONTROLLO

SCHEMA DI CONTROLLO TIPICO DELLA POMPA DI CALORE

MINI-SPLIT, ELENCO PUNTI E SEQUENZA DI

FUNZIONAMENTO

VARIE. SCHEMA DI CONTROLLO, ELENCO PUNTI E

SEQUENZA OPERATIVA

SCHEMA ARCHITETTONICO DDC

SCHEMA ISOMETRICO ACQUA DI RISCALDAMENTO - SITO HEAVY

LEGENDA ELETTRICA - TAVOLA 1

LEGENDA ELETTRICA - TAVOLA 2

PIANTA IMPIANTO DI TERRA - GENERALE

PIANTA IMPIANTO DI TERRA - AREA 'A'

PIANTA IMPIANTO DI TERRA - AREA 'B'

PIANTA IMPIANTO DI ILLUMINAZIONE GENERALE

PIANTA IMPIANTO DI ILLUMINAZIONE - AREA "A"

PIANTA IMPIANTO DI ILLUMINAZIONE - AREA "B"

PIANTA IMPIANTO DI FORZA MOTRICE - GENERALE

PIANTA IMPIANTO DI FORZA MOTRICE - AREA 'A'

PIANTA IMPIANTO DI FORZA MOTRICE - AREA 'B'

PIANTA TETTO IMPIANTO DI FORZA MOTRICE

PIANTE INGRANDITE IMPIANTO DI FORZA MOTRICE

PIANTE INGRANDITE IMPIANTO DI ILLUMINAZIONE

TABELLA QUADRI - MDP

TABELLA QUADRI - PP1

TABELLA QUADRI - PP2

TABELLA QUADRI - LP1

TABELLA QUADRI - RP1

AC SCHEMA UNIFILARE ELETTRICO

DETTAGLI ELETTRICI - TAVOLA 1

DETTAGLI ELETTRICI - TAVOLA 2

DETTAGLI ELETTRICI - TAVOLA 3

DETTAGLI ELETTRICI - TAVOLA 4

DETTAGLI ELETTRICI - TAVOLA 5

DETTAGLI ELETTRICI - TAVOLA 6

DETTAGLI ELETTRICI - TAVOLA 7

DETTAGLI IMPIANTO DI ILLUMINAZIONE - TAVOLA 1

DETTAGLI IMPIANTO DI ILLUMINAZIONE - TAVOLA 2

DETTAGLI IMPIANTO DI ILLUMINAZIONE - TAVOLA 3

TABELLA CORPI ILLUMINANTI

LEGENDA DELLE TELECOMUNICAZIONI

PIANTA DELLE TELECOMUNICAZIONI PIANO TERRA

PIANTA INGRANDITA LOCALE TELECOMUNICAZIONI

DIAGRAMMA ALTIMETRICO DELLE TELECOMUNICAZIONI

TAVOLA 1 DETTAGLI TELECOMUNICAZIONI

TAVOLA 2 DETTAGLI TELECOMUNICAZIONI

TAVOLA 3 DETTAGLI TELECOMUNICAZIONI

TAVOLA 4 DETTAGLI TELECOMUNICAZIONI

DIAGRAMMA RISER DELLE TELECOMUNICAZIONI

LEGENDA SITO 1

SITO 1 NOTE GENERALI

PERCORSO DI MOVIMENTAZIONE CANTIERE

PIANTA DEL RILIEVO TOPOGRAFICO - SITO 1

PIANTA DEI SOTTOSERVIZI - SITO 1

SITO 1 - PLANIMETRIA DELLE INDAGINI GEOTECNICHE

SONDAGGI 1/5

SONDAGGI 2/5

SONDAGGI 3/5

SONDAGGI 4/5

SONDAGGI 5/5

SITO 1 PIANO DEMOLIZIONE

SITO 1 PLANIMETRIA DEL SITO

SITO 1 PLANIMETRIA DEI LIVELLAMENTI

SITO 1 PLANIMETRIA DEI GIUNTI NELLA PAVIMENTAZIONE

SITO 1 PIANTA DEI SOTTOSERVIZI

DETTAGLI CIVILI

DETTAGLI CIVILI

IMPIANTO DI FORZA MOTRICE PIANTA DEL SITO

IMPIANTO DI ILLUMINAZIONE PIANTA DEL SITO

FOTO DI RIFERIMENTO DEL SITO ELETTRICO SITO 1 - P002

PIANTA GENERALE DI TELECOMUNICAZIONE SITO 1 - P002

DETTAGLI ELETTRICI - TAVOLA 8

DETTAGLI ELETTRICI - TAVOLA 9

DETTAGLI IMPIANTO DI ILLUMINAZIONE - TAVOLA 4

DETTAGLI IMPIANTO DI ILLUMINAZIONE - TAVOLA 5

DETTAGLI IMPIANTO DI ILLUMINAZIONE - TAVOLA 6

DETTAGLI IMPIANTO DI ILLUMINAZIONE - TAVOLA 7

DC SCHEMA UNIFILARE ELETTRICO

COLLEGAMENTI SISTEMA ANTICADUTA 1/2

COLLEGAMENTI SISTEMA ANTICADUTA 2/2

PIANO ATTREZZATURE SOTTOSTAZIONE 23/1065, PIANO

DI MESSA A TERRA

BASSA TENSIONE SOTTOSTAZIONE 23/1065 QUADRO

FRONTALE

SOTTOSTAZIONE DI BASSA TENSIONE 23/1065

FONDAZIONE QUADRO E DETTAGLI DI FISSAGGIO AL

PAVIMENTO

SOTTOSTAZIONE BASSA TENSIONE 22/1064 230V

SCHEMA A LINEA SINGOLA

PIANTA IMPIANTO PROTEZIONE DA SCARICHE ATMOSFERICHE - GENERALE

PIANTA DEL TETTO - SISTEMA DI PROTEZIONE ANTICADUTA

TABELLA QUADRI - RP2

GI001 14121415 TITLE SHEET AND LOCATION MAPS

GI011 14121416 DRAWING INDEX

GI020 14121417 GENERAL AND SITE LEGEND

GI030 14121418 ABBREVIATIONS - SHEET 1

GI031 14121419 ABBREVIATIONS - SHEET 2

GI032 14121420 ABBREVIATIONS - SHEET 3

GI033 14121421 ABBREVIATIONS - SHEET 4

GI034 14121422 ABBREVIATIONS - SHEET 5

GI035 14121423 ABBREVIATIONS - SHEET 6

GI001A 14121424 LIFE SAFETY CODE NARRATIVE

GI002A 14121425 LIFE SAFETY CODE NARRATIVE

GI003A 14121426 LIFE SAFETY CODE NARRATIVE

GI004A 14121427 LIFE SAFETY CODE NARRATIVE

GI005A 14121428 LIFE SAFETY CODE NARRATIVE

GI101A 14121429 CODE COMPLIANCE SITE PLAN

GI102A 14121430 LIFE SAFETY OCCUPANCY CLASSIFICATION PLAN

GI103A 14121431 LIFE SAFETY FLOOR PLAN - AREA 'A'

GI104A 14121432 LIFE SAFETY FLOOR PLAN - AREA 'B'

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

NO SCALE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

KMS

/1

/2

:0 :4

A

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \D

R A

W

IN

G

IN

D E

X C

O M

P O

S

IT

E B

L D

C R b g ro th e .r v t

D R

A W

IN

G

IN

D

E X

GI011

BKG BKG BAG

G I0

D

R A

W

IN

G

IN

D E

X

14121416 2 429

DRAWING INDEX

C-001A 14121433 SITE 1 LEGEND

C-002A 14121434 SITE 1 GENERAL NOTES

C-003A 14121435 HAUL ROUTE

V-101A 14121436 TOPOGRAPHIC SURVEY MAP - SITE 1

VU101A 14121437 UNDERGROUND UTILITIES MAP - SITE 1

B-101A 14121438 SITE 1 - GEOTECHNICAL SURVEY PLAN

B-201A 14121439 BORING LOGS 1/5

B-202A 14121440 BORING LOGS 2/5

B-203A 14121441 BORING LOGS 3/5

B-204A 14121442 BORING LOGS 4/5

B-205A 14121443 BORING LOGS 5/5

CD101A 14121444 SITE 1 DEMOLITION PLAN

CS101A 14121445 SITE 1 SITE PLAN

CG101A 14121446 SITE 1 GRADING PLAN

CP101A 14121447 SITE 1 PAVEMENT JOINT LAYOUT PLAN

CU101A 14121448 SITE 1 UTILITY PLAN

CK551 14121449 CIVIL DETAILS

CK552 14121450 CIVIL DETAILS

ES101A 14121451 P-002 RADR SITE 1 ELECTRICAL POWER SITE

PLAN

ES102A 14121452 P-002 RADR SITE 1 ELECTRICAL LIGHTING SITE

PLAN

ES103A 14121453 P-002 RADR SITE 1 - ELECTRICAL SITE

REFERENCE PHOTOS

TS101A 14121454 P-002 RADR SITE 1 TELECOM SITE PLAN

LD101A 14121455 EXISTING CONDITIONS AND DEMOLITIONS SITE

PLAN

LS102A 14121456 DESIGN SITE AND PLANTING PLAN

LK501A 14121457 PLANT MATERIALS SCHEDULE AND DETAILS

S-001A 14121458 GENERAL NOTES 1/2

S-002A 14121459 GENERAL NOTES 2/2

SB101A 14121460 OVERALL FOUNDATION PLAN

SB102A 14121461 FOUNDATION PLAN - AREA A

SB103A 14121462 FOUNDATION PLAN - AREA B

SB104A 14121463 SLAB ON GRADE PLAN

SB201A 14121464 ELEVATION ON AXIS

SB202A 14121465 ELEVATION ON AXIS

SF101A 14121466 OVERALL ROOF FRAMING PLAN

SF102A 14121467 ROOF FRAMING PLAN - AREA A

SF103A 14121468 ROOF FRAMING PLAN - AREA B

SF104A 14121469 STRUCTURAL SCHEME

SF301A 14121470 SECTIONS

SF401A 14121471 SERVICE AREA PLANS AND SECTIONS

SR301A 14121472 FOUNDATION REINFORCEMENT 1/2

SR302A 14121473 FOUNDATION REINFORCEMENT 2/2

SR303A 14121474 SERVICE AREA WALLS' REINFORCEMENT

SR304A 14121475 SERVICE AREA SLAB REINFORCEMENT

SK551 14121476 TYPICAL FOUNDATIONS REINFORCEMENT'S

DETAILS

SK552 14121477 SLAB ON GRADE DETAILS

SK553 14121478 MISCELLANEOUS REINFORCEMENT DETAILS

SK554 14121479 TYPICAL PERIMETRAL DETAILS

SK555 14121480 BASE PLATE DETAIL

SK556 14121481 STEEL JOINTS DETAILS 1/3

SK557 14121482 STEEL JOINTS DETAILS 2/3

SK558 14121483 STEEL JOINTS DETAILS 3/3

SK559 14121484 CONNECTIONS DETAILS 1/2

SK560 14121485 CONNECTIONS DETAILS 2/2

SK561 14121486 FACADE FRAMING DETAILS 1/3

SK562 14121487 FACADE FRAMING DETAILS 2/3

SK563 14121488 FACADE FRAMING DETAILS 3/3

SK564 14121489 FACADE FRAMING BASE CONNECTION

SK565 14121490 FACADE FRAMING CONNECTIONS 1/2

SK566 14121491 FACADE FRAMING CONNECTIONS 2/2

SK567 14121492 MISCELLANEOUS DETAILS

SK568 14121493 FALL PROTECTION SYSTEM CONNECTIONS 1/2

SK569 14121494 FALL PROTECTION SYSTEM CONNECTIONS 2/2

AE101A 14121495 OVERALL GROUND FLOOR PLAN

AE102A 14121496 GROUND FLOOR PLAN - AREA 'A'

AE103A 14121497 GROUND FLOOR PLAN - AREA 'B'

AE104A 14121498 FINISH PLAN AND SCHEDULE

AE111A 14121499 REFLECTED CEILING PLAN - AREA A

AE112A 14121500 REFLECTED CEILING PLAN - AREA B

AE121A 14121501 ROOF PLAN

AE131A 14121502 AIR BARRIER PLAN AND SECTION

AE201A 14121503 EXTERIOR ELEVATIONS

AE202A 14121504 EXTERIOR ELEVATIONS

AE301A 14121505 BUILDING SECTIONS

AE302A 14121506 WALL SECTIONS

AE401A 14121507 ENLARGED PLAN - RESTROOM

AE601A 14121508 DOOR SCHEDULE

AJ101A 14121509 ROOF PLAN - FALL PROTECTION SYSTEM

AK551 14121510 INTERIOR WALL TYPES

AK552 14121511 EXTERIOR WALL DETAILS

AK553 14121512 EXTERIOR WALL DETAILS

AK554 14121513 ROOF DETAILS

AK555 14121514 OPENING DETAILS

AK556 14121515 MISCELLANEOUS DETAILS

AK557 14121516 SIGNAGE DETAILS

FA001A 14121517 FIRE ALARM GENERAL NOTES, LEGEND, AND

DIAGRAMS

FA101A 14121518 FIRE ALARM AUDIBILITY PLAN

FA102A 14121519 FIRE ALARM PLAN - AREA 'A'

FA103A 14121520 FIRE ALARM PLAN - AREA 'B'

FX001A 14121521 FIRE SUPPRESSION GENERAL NOTES

FX101A 14121522 FIRE SUPPRESSION HAZARD CLASSIFICATION

PLAN

FX301A 14121523 FIRE SUPPRESSION SECTIONS

P-001 14121524 PIPING AND INSTRUMENTATION DIAGRAM

LEGEND

PL101A 14121525 HEAVY FIRST FLOOR OVERALL PLUMBING PLAN

PL401A 14121526 HEAVY RESTROOM ENLARGED PLUMBING PLAN

PL501A 14121527 HEAVY PLUMBING DETAIL - SHEET 1

PL502A 14121528 HEAVY PLUMBING DETAIL - SHEET 2

PL601A 14121529 HEAVY REPAIR PLUMBING SCHEDULES

PL901A 14121530 HEAVY PLUMBING ISOMETRICS

M-001 14121531 MECHANICAL HVAC LEGEND

MH101A 14121532 HEAVY REPAIR HVAC ZONE PLAN

MH102A 14121533 HEAVY REPAIR HVAC PIPING PLAN

MH111A 14121534 HEAVY REPAIR HVAC DUCT PLAN

MH401A 14121535 HEAVY ENLARGED PLAN MECH ROOM

MH501A 14121536 MECHANICAL DETAILS - SHEET 1

MH502A 14121537 MECHANICAL DETAILS - SHEET 2

MH503A 14121538 MECHANICAL DETAILS - SHEET 3

MH504A 14121539 MECHANICAL DETAILS - SHEET 4

MH505A 14121540 MECHANICAL DETAILS - SHEET 5

MH506A 14121541 MECHANICAL DETAILS - SHEET 6

MH507A 14121542 MECHANICAL DETAILS - SHEET 7

MH508A 14121543 MECHANICAL DETAILS - SHEET 8

MH509A 14121544 MECHANICAL DETAILS - SHEET 9

MH510A 14121545 MECHANICAL DETAILS - SHEET 10

MH511A 14121546 MECHANICAL DETAILS - SHEET 11

MH512A 14121547 MECHANICAL DETAILS - SHEET 12

MH601A 14121548 HEAVY REPAIR MECHANICAL SCHEDULES SHEET

MH602A 14121549 HEAVY REPAIR MECHANICAL SCHEDULES SHEET

MH603A 14121550 HEAVY REPAIR MECHANICAL SCHEDULES SHEET

MH604A 14121551 HEAVY REPAIR MECHANICAL SCHEDULES SHEET

MH605A 14121552 HEAVY REPAIR MECHANICAL SCHEDULES SHEET

MH606A 14121553 HEAVY REPAIR MECHANICAL SCHEDULES SHEET

MH607A 14121554 HEAVY REPAIR MECHANICAL SCHEDULES SHEET

MH701A 14121555 AHU CONTROL SCHEMATIC AND SEQUENCE OF

OPERATION

MH702A 14121556 AHU CONTROL SCHEMATIC AND SEQUENCE OF

OPERATION

MH703A 14121557 HEATING SYSTEM CONTROL SCHEMATIC AND

SEQUENCE OF CONTROL

MH704A 14121558 TYPCIAL MINI-SPLIT HEAT PUMP CONTROL

SCHEMATIC, POINTS LIST AND SEQUENCE OF

OPERATION

MH705A 14121559 MISC. CONTROL SCHEMATIC, POINTS LISTS AND

SEQUENCE OF OPERATION

MH706A 14121560 DDC ARCHITECTURAL DIAGRAM

MH901A 14121561 HEAVY HEATING WATER ISOMETRIC

E-001 14121562 ELECTRICAL LEGEND - SHEET 1

E-002 14121563 ELECTRICAL LEGEND - SHEET 2

EJ101A 14121564 GROUNDING PLAN - OVERALL

EJ102A 14121565 GROUNDING PLAN - AREA 'A'

EJ103A 14121566 GROUNDING PLAN - AREA 'B'

EJ110A 14121567 LIGHTNING PROTECTION PLAN

EL101A 14121568 LIGHTING PLAN - OVERALL

EL102A 14121569 LIGHTING PLAN - AREA 'A'

EL103A 14121570 LIGHTING PLAN - AREA 'B'

EL401A 14121571 ENLARGED LIGHTING PLANS

EP101A 14121572 POWER PLAN - OVERALL

EP102A 14121573 POWER PLAN - AREA 'A'

EP103A 14121574 POWER PLAN - AREA 'B'

EP110A 14121575 ROOF POWER PLAN

EP401A 14121576 ENLARGED POWER PLANS

EP601A 14121577 AC ONELINE DIAGRAM

EP602A 14121578 PANEL SCHEDULES - MDP

EP603A 14121579 PANEL SCHEDULES - PP1

EP604A 14121580 PANEL SCHEDULES - PP2

EP605A 14121581 PANEL SCHEDULES - LP1

EP606A 14121582 PANEL SCHEDULES - RP1

EP607A 14121583 PANEL SCHEDULES - RP2

EP608A 14121584 DC ONELINE DIAGRAM

EK551 14121585 ELECTRICAL DETAILS - SHEET 1

EK552 14121586 ELECTRICAL DETAILS - SHEET 2

EK553 14121587 ELECTRICAL DETAILS - SHEET 3

EK554 14121588 ELECTRICAL DETAILS - SHEET 4

EK555 14121589 ELECTRICAL DETAILS - SHEET 5

EK556 14121590 ELECTRICAL DETAILS - SHEET 6

EK557 14121591 ELECTRICAL DETAILS - SHEET 7

EK558 14121592 ELECTRICAL DETAILS - SHEET 8

EK559 14121593 ELECTRICAL DETAILS - SHEET 9

EK570 14121594 ELECTRICAL LIGHTING DETAILS - SHEET 1

EK571 14121595 ELECTRICAL LIGHTING DETAILS - SHEET 2

EK572 14121596 ELECTRICAL LIGHTING DETAILS - SHEET 3

EK573 14121597 ELECTRICAL LIGHTING DETAILS - SHEET 4

EK574 14121598 ELECTRICAL LIGHTING DETAILS - SHEET 5

EK575 14121599 ELECTRICAL LIGHTING DETAILS - SHEET 6

EK576 14121600 ELECTRICAL LIGHTING DETAILS - SHEET 7

EK651 14121601 LIGHT FIXTURE SCHEDULE

T-001 14121602 TELECOMMUNICATIONS LEGEND

TP101A 14121603 TELECOM GROUND FLOOR PLAN

TP401A 14121604 ENLARGED TELECOM ROOM PLAN

TR601A 14121605 TELECOMMUNICATIONS OSP RISER DIAGRAM

TR602A 14121606 TELECOMMUNICATIONS RISER DIAGRAM

TK551 14121607 TELECOM DETAILS SHEET 1

TK552 14121608 TELECOM DETAILS SHEET 2

TK553 14121609 TELECOM DETAILS SHEET 3

TK554 14121610 TELECOM DETAILS SHEET 4

GENERAL

SITE

LANDSCAPING

STRUCTURAL

FIRE PROTECTION

MECHANICAL - PLUMBING

MECHANICAL - HVAC

TELECOMMUNICATIONS

ARCHITECTURAL ELECTRICAL

REFERENCE DRAWINGS

REFERENCE

NO.

NAVFAC

DRAWING NO. DRAWING TITLE SHEET NAME (FOREIGN)

REFERENCE

NO.

NAVFAC

DRAWING NO. DRAWING TITLE SHEET NAME (FOREIGN)

REFERENCE

NO.

NAVFAC

DRAWING NO. DRAWING TITLE SHEET NAME (FOREIGN)

001 SUBSTATION 23/1065 EQUIPMENT PLAN,

GROUNDING PLAN

010/012 LOW VOLTAGE SWITCHGEAR SUBSTATION

23/1065 SWITCHBOARD FRONT

012/015 LOW VOLTAGE SWITCHGEAR SUBSTATION

23/1065 SWITCHBOARD FOUNDATION AND

DETAILS OF FIXING TO THE FLOOR

001/--- LOW VOLTAGE SWITCHGEAR SUBSTATION

22/1064 230V SINGLE LINE DIAGRAM

LE DIMENSIONI E/O LE ALTEZZE SEGNATE COSÌ (‡) SONO PRESUNTE E POSSONO

ESSERE VARIATE DALL'APPALTATORE PER ADATTARSI ALL'ATTREZZATURA

FORNITA. LE DIMENSIONI FINALI SONO SOGGETTE ALLA REVISIONE

DELL'INGEGNERE.

POZZETTO FOGNARIO

SIMBOLO DEL NORD

NUMERO DEL DETTAGLIO

NUMERO DELLA TAVOLA DOVE LA SEZIONE

O IL PROSPETTO E' INDICATO

NUMERO DEL DETTAGLIO

NUMERO DELLA TAVOLA DOVE LA

SEZIONE O IL PROSPETTO E' INDICATO

SEZIONE

PROSPETTO

DETTAGLIOSEZIONE/PROSPETTO

LETTERE/NUMERI, DETTAGLIO

NUMERO

NUMERO DELLA TAVOLA DOVE LA SEZIONE,

PROSPETTO O DETTAGLIO E' TAGLIATO

NUMERO STANZA

NUMERO PORTA

GRIGLIA

GIUNTO DI CONTROLLO - STUCCO O INTONACO

GIUNTO DI CONTROLLO - STUCCO E CMU

GIUNTO DI ESPANSIONE

NUMERO PORTA

NUMERO PORTA

NUMERO PORTA

PAVIMENTAZIONE

VETRO (PROSPETTO)

ISOLAMENTO IN ROTOLI

ISOLAMENTO RIGIDO

ISOLAMENTO RIGIDO

COMPENSATO

LEGNO GREZZO (IN SEZIONE)

MATTONE IN SEZIONE

UNITA' DI MURATURA IN CEMENTO

METALLO NON FERROSO

ACCIAIO (SEZIONE)

RETE ELETTROSALDATA DI

ARMATURA

BARRE DI ARMATURA IN CEMENTO

CEMENTO

STRATO DI BASE IN AGGREGATO

FRANTUMATO GRADUATO

SABBIA, CMU, INTONACO

ROCCIA FRANTUMATA

ROCCIA OPPURE TERRA INTATTA

TERRA

POZZETTO

BACINO DELLA RACCOLTA ACQUE PIOVANE O

IMMISSIONE

MURO DI TESTA

IDRANTE

IDRANTE ANTINCENDIO

PULIZIA

RIDUTTORE TUBO

VALVOLA A SARACINESCA

VALVOLA A SARACINESCA CON INTERRUTTORE A TAMBURO

VALVOLA DI CONTROLLO

VALVOLA A TAPPO

VALVOLA A GLOBO

VALVOLA A SFERA

VALVOLA DI PRESSIONE

CONNETTORE LINEA

BLOCCO TRHUST

VALVOLA POST INDICATORE

POZZO DELL'IDRANTE DEL CARBURANTE

VALVOLA ACQUA

POZZETTO ACQUA

POZZETTO GAS

LE DIMENSIONI E/O LE QUOTE COSÌ CONTRASSEGNATE (+/-) DEVONO ESSERE

VERIFICATE SUL CAMPO DALL'APPALTATORE.

LE DIMENSIONI SONO GENERALMENTE IN SCALA, MA NON DEVONO ESSERE

SCALATE. UTILIZZARE LE DIMENSIONI INDICATE.

LE ALTEZZE DELL'EDIFICIO SONO INDICATE IN MILLIMETRI.

I DIAMETRI DEI TUBI SONO INDICATI IN MILLIMETRI.

G E

N E

R A

LE

E

L E

G E

N D

A D

E L

S

IT

O

XX

XX

DETAIL NUMBER

SHEET NUMBER OF SHEET WHERE

SECTION OR ELEVATION IS SHOWN

NORTH SYMBOL

PIPE REDUCER

GATE VALVE

GATE VALVE WITH TAMPER SWITCH

CHECK VALVE

PLUG VALVE

GLOBE VALVE

BALL VALVE

PRESSURE VALVE

UTILITY LINE PLUG

THRUST BLOCKING

POST INDICATOR VALVE

XXX

XXX

HANDHOLE OR MANHOLE

EHH - ELECTRICAL HANDHOLE

EMH - ELECTRICAL MANHOLE

CHH - COMMUNICATION HANDHOLE

CMH - COMMUNICATION MANHOLE

SANITARY SEWER MANHOLE

MANHOLE

STORM CATCH BASIN OR INTAKE

HEADWALL

YARD HYDRANT

FIRE HYDRANT

CLEAN OUT

SSMH

MH

CB

HDWL

FH

CO

S

D

CB

F FUEL HYDRANT PIT

W WATER VALVE VAULT

W WATER MANHOLE

G NATURAL GAS MANHOLE

X

LV

2103 ROOM NUMBER

DOOR NUMBER

COLUMN LINE

GRADED CRUSHED AGGREGATE

BASE COURSE

LOUVER

WALL TYPE

KEYNOTE

EARTH

ROCK OR UNDISTURBED EARTH

CRUSHED ROCK

SAND, CMU, PLASTER

CONCRETE

WELDED WIRE REINFORCEMENT

STEEL (IN SECTION)

NON-FERROUS METAL

CONCRETE MASONRY UNIT

BRICK IN SECTION

ROUGH WOOD (IN SECTION)

PLYWOOD

RIGID INSULATION

RIGID INSULATION

BATT INSULATION

GLASS (ELEVATION)

REINFORCING BARS IN

CONCRETE

PAVEMENT

CONTROL JOINT - STUCCO OR PLASTER

CONTROL JOINT - STUCCO AND CMU

EXPANSION JOINT

PLAN NORTH

DIMENSIONS AND SCALESITE UTILITY LEGEND

1. DIMENSIONS AND/OR ELEVATIONS MARKED THUS (‡) ARE ASSUMED AND MAY BE

VARIED BY THE CONTRACTOR TO SUIT EQUIPMENT FURNISHED. FINAL

DIMENSIONS ARE SUBJECT TO THE REVIEW OF THE ENGINEER.

2. DIMENSIONS AND/OR ELEVATIONS MARKED THUS (+/-) MUST BE VERIFIED IN THE

FIELD BY THE CONTRACTOR.

3. DIMENSIONS ARE GENERALLY TO SCALE, BUT SHOULD NOT BE SCALED. USE

DIMENSIONS SHOWN.

4. BUILDING ELEVATIONS ARE SHOWN IN MILLIMETERS.

5. PIPE DIAMETERS ARE SHOWN IN MILLIMETERS.

MATERIAL SYMBOLS

DETAIL NUMBER

SHEET NUMBER OF SHEET

WHERE DETAIL IS SHOWN

ARCHITECTURAL SYMBOLS

REFERENCE SYMBOLS

SECTION/ELEVATION

LETTER/NUMBER, DETAIL NUMBER

SHEET NUMBER OF SHEET WHERE

SECTION, ELEVATION OR DETAIL IS CUT

SECTION

ELEVATION

DETAIL

XXXXXX

EXISTING HANDHOLE OR MANHOLE

EHH - ELECTRICAL HANDHOLE

EMH - ELECTRICAL MANHOLE

CHH - COMMUNICATION HANDHOLE

CMH - COMMUNICATION MANHOLE

EXISTING LOW VOLTAGE < 1000V DUCTBANK

ELVx ELVx

LOW VOLTAGE < 1000V DUCTBANKELV ELV

EXISTING HIGH VOLTAGE > 1000V DUCTBANKEHVx EHVx

EXISTING COMMUNICATION DUCTBANKCUx CUx

COMMUNICATION DUCTBANKCU CU

< DI BASSA TENSIONE ESISTENTE 1000V DUCTBANK

BASSA TENSIONE < 1000V DUCTBANK

> AD ALTA TENSIONE ESISTENTE 1000V DUCTBANK

COMUNICAZIONE ESISTENTE DUCTBANK

COMUNICAZIONE DUCTBANK

FORO O TOMBINO

EHH - FORO ELETTRICO

EMH - TOMBINO ELETTRICO

CHH - COMUNICAZIONE HANDHOLE

CMH - TOMBINO DI COMUNICAZIONE

TOMBINO O TOMBINO ESISTENTE

EHH - FORO ELETTRICO

EMH - TOMBINO ELETTRICO

CHH - COMUNICAZIONE HANDHOLE

CMH - TOMBINO DI COMUNICAZIONE

TO BE DEMOLISHED

DA DEMOLIRE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

NO SCALE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

KMS

/1

/2

:0 :4

A

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \D

R A

W

IN

G

IN

D E

X C

O M

P O

S

IT

E B

L D

C R b g ro th e .r v t

G E

N E

R A

L A

N D

S

IT

E L

E G

E N

D

GI020

BKG JMK BAG

G I0

G

E N

E R

A L

A N

D S

IT

E

L E

G E

N D

14121417 3 429

TUTTE LE ABBREVIAZIONI MOSTRATE IN QUESTA LEGENDA

POTREBBERO NON APPARIRE IN QUESTO SET DI DISEGNI

AMPERAGGIO, CAMBIO DI GRADO AERATORE

CONTROLLO DI ACCESSO, ARIA CONDIZIONATA

UNITA' ARIA CONDIZIONATA

ADESIVO DI ANCORAGGIO

BULLONI DI ANCORAGGIO

AZIONE CONTRO LA BARRIERE ARCHITETTONICHE

STRATO DI BASE AGGREGATO

SOPRA

ACRE; CORRENTE ALTERNATA; ACIDO

INTERRUTTORE ARIA

ACCESSIBILE

UNITÀ CONDENSATRICE RAFFREDDAMENTO AD ARIA

ACCURATO

ISTITUTO DI CEMENTO AMERICANA

PUNTO DI CONTROLLO ACCESSI

SISTEMA DI CONTROLLO DELLE CENERI

PORTA DI ACCESSO

PANNELLO DI ACCESSO

CAVO IN ALLUMINIO RINFORZATO IN ACCIAIO

ACUSTICO

PIASTRELLE PER SOFFITTI ACUSTICI

UNITA' ARIA CONDIZIONATA

VALVOLA DI CONTROLLO AUTOMATICA

VALVOLA DI CONTROLLO AUTOMATICA A 3 VIE

SFIATO DELL'ACIDO

SCARICO DEI RIFIUTI ACIDI

PORTA DI ACCESSO, ESSICCATORE

LEGGE AMERICANA SULLA DISABILITA'

COMPAGNIA DI ABU DHABI DI DISTRIBUZIONE

AGGIUN TIVO

ADDENDO

ADESIVO/COLLA

ADIACENTE; CONTIGUO; ADATTO (IN GRADO)

NODO DI DISTRIBUZIONE DELL'AREA

OPERATORE DI PORTA AUTOMATICO

ARIA DI AERAZIONE

TELAIO DI AMPERE; FREQUENZA AUDIO; FIAMMA

ARRESTATORE

DAL PAVIMENTO FINITO

DAL GRADO FINITO

FILTRO DELL'ARIA (SOLO VENTILAZIONE E ARIA

CONDIZIONATA)

AGITAZIONE ARIA

ATTREZZATURE DI TERRA PER AEREI

AGGREGATO

INDICATORE D'ARRESTO

AMPERE PER ORA

SERPENTINA DI RISCALDAMENTO DELL'ARIA

ANCORAGGIO

UNITÀ DI TRATTAMENTO DELL'ARIA

INGRESSO DELL'AREA, INGRESSO ANALOGICO

CORRENTE D'INTERRUZIONE IN AMPERE (CAPACITÀ)

ISTITUTO AMERICANO DELLE COSTRUZIONI IN

ACCIAIO

BATTENTE ATTIVO; ALLUMINIO

ALTERNATIVA; QUOTA

ALLUMINIO

AMBIENTE

AMPERE

QUANTITA'

ANODO

SEGNALATORE

ANODIZZARE

ISTITUTO NAZIONALE STANDARD AMERICANO

ANTENNA

USCITA ANALOGICA

APPROSSIMATIVO

UNITÀ DI POTENZA AUSILIARIA

APPROVATO

ARCHITETTURA; ARCHITETTURA

ISTITUTO DI REFRIGERAZIONE AMERICANO

VALVOLA DI RILASCIO DELL'ARIA

SEPARATORE ARIA; ALIMENTAZIONE D'ARIA

SOCIETA' DEGLI INGEGNERI CIVILI AMERICANA

AZIONAMENTO MECCANICO A VELOCITÀ'

REGOLABILE

ASFALTO

ASSEMBLAGGIO

SOCIETA' AMERICANA PER I TEST SUI MATERIALI

AMPERAGGIO

PIASTRELLE PER SOFFITTO ACUSTICO

PROTEZIONE ANTITERRORISTICA

COMMUTATORE AUTOMATICO

AUTOMATICO

AUSILIARIO

BARRIERA PER VEICOLI

MEDIA

CAVO CALIBRATO AMERICANO

TRATTAMENTO ACUSTICO DELLE PARETI

ACQUA DI RAFFREDDAMENTO AUSILIARE

VAPORE AUSILIARIO

PIASTRA DI BASE

SPALLA A SPALLA

ASSE; BATTERIA

BACHECA, SPURGO DELLA CALDAIA

CALDAIA A COMBUSTIONE ARIA

CALDAIA A CARBONE

RISCALDAMENTO EDIFICIO A CONDENSAZIONE

LAVAGNA

CONFINE

GIUNTO DI ESPANSIONE PER MATTONI

SMUSSATURA

ENTRAMBE LE FACCE

SOTTO IL PAVIMENTO FINITO

DISCONNETTORE DI RETE

UNITA' DI ALIMENTAZIONE ACQUA CALDAIA

ACQUA DI ALIMENTAZIONE DELLE CALDAIA

GAS PROPANO

CALDAIA A GAS

FILTRO A MANICA

RISCALDAMENTO A VAPORE

BITUMINOSO

GIUNTI ORIZZONTALI

INTERUUTTORE

LINEA DI BASE, ALLINEAMENTO

DRENAGGI CALDAIA

EDIFICIO

CALDAIA

REATTORE

SFIATI CALDAIA

SOTTO

TRAVE(I); CAPISALDI ;MOMENTO A FLESSIONE

INCOLLAGGIO

BRUCIATORE (GAS DI SCARICO, INCENERITORE, ECC.)

FONDO DI

INIZIO ALLINEAMENTO

RETRO DEL CORDOLO

SOTTO IL CONDOTTO DELL'ARIA

PARTE BASSA DELLA FONDAZIONE

INTRADOSSO DELLA CINTURA

INTRADOSSO DELL'ACCIAO

BOTTOM

INTRADOSSO DEL CAVIDOTTO

SCATOLA HVAC (MISCELAZIONE, RISCALDAMENTO,

VOLUME VARIABILE)

INTONACATO DIETRO; PUNTO DI INIZIO, INIZIO DEL

PUNTO DI ALLINEAMENTO

VALVOLA DI CONTROLLO DELLA CONTROPRESSIONE

SOPRA IL CONTROSOFFITTO; REGOLATORE DI

VELOCITA' ELETTRONICO

AMIANTO

LIBRERIA, TRA I CENTRI, DIAMETRO PASSANTE;

CATENA INFERIORE; CODICE EDILIZIO; INIZIO CURVA

CONTROVENTATURA

CONNETTORE

INTERRUZIONE LIVELLO

PORTATA

PIASTRA PORTANTE

MATTONE

INTERRUTTORE

STAFFA

ACQUA SALMASTRA

BRONZO

ENTRAMBI I LATI

PIANO TERRA

ACCUMULO TAMPONE

UNITA TERMICA BRITANNICA

BTU PER ORA

TRA

COPERTURA TETTI A STRATI

INDICATORE DI GUASTO

INIZIO TANGENTE VERTICALE-INTERCETTA DELLA

CURVA

INIZIO PROFILO

DUE VIE

ASPIRATORE

ACQUA DI RISCIACQUO

CONDOTTO;CELSIUS; CANALE;CALCESTRUZZO;

BOBINA

CENTRO

CORDOLO E GRONDAIA

CAVO; ARIA COMPRESSA

ARMADIETTO

ESTRAZIONE ARIA COMPRESSA

ANTIORARIO

DIFFUSORE A SOFFITTO

CICLO DI COPERTURA

CICLO TROPPOPIENO

DRENAGGIO CHIMICO

INDICATORE DI GUASTO

INDICATORE DI GUASTO

CEMENTO

INTONACO CEMENTIZIO

CONTROLLO DELLE EMISSIONI

CERAMICA

SISTEMA DI ALIMENTAZIONE CHIMICA

PAVIMENTAZIONE CONDUTTIVA

SCOSSALINA

PIEDI CUBI PER MINUTO

ALIMENTATORE CHIMICO

PIEDI CUBI PER SECONDO

PARASPIGOLO, GRIGLIA A SOFFITTO

REFRIGERATORE

LAVAGNA

CANALE

CHIMICO

SMUSSATURA

CARICABATTERIA

CANNA FUMARIA

CONTROLLO

LAMIERA STRIATA

CROMATO

SISTEMA DI MOVIMENTAZIONE DEL CARBONE

BYPASS ACQUA RAFFREDDATA

RITORNO ACQUA RAFFREDDATA

FORNITURA ACQUA RAFFREDDATA

SISTEMA IDROGENO

GHISA, CORDOLO CON BOCCHETTA DI INGRESSO

GETTATO IN OPERA; TUBO IN GHISA; SPORTELLO DI

PULIZIA

CIRCOLARE

TUBO IN GHISA PER TERRENO

RITORNO DELL'ACQUA IN CIRCOLO

GIUNTO DI COSTRUZIONE

CIRCUITO

INTERRUTTORE DI CIRCUITO

LINEA MEDIANA; SPAZIO LIBERO; VICINO

CHIARIFICATORE

FUSIBILE LIMITATORE DI CORRENTE

SOFFITTO; RAFFREDDAMENTO; CLORO GASSOSO

ALTEZZA SOFFITTO

VETRO TRASPARENTE

GIUNTO DI CONTROLLO

LINEA LIMITE DEL CONTRATTO, LIQUIDO DI CLORO

ARMADIO

CHIUSURA

SPAZIO LIBERO (TOLLERANZA)

SOLUZIONE DI CLORO; CONSOLE DI CONTROLLO O

PANNELLO.

CLORO VACUUM

ACQUA CLORATA

VETRO RETINATO TRASPARENTE

CENTIMETRO (I)

METRO CUBO PER ORA

TUBO CORRUGATO METALLICO; COMPRESSORE

COMPOSITO

MUTARURA IN CALCESTRUZZO

LAVORI DEL COMANDO MILITARE

CONDOTTO; CONDENSATO; CONDENSATORE

LATTICE DI NEOPRENE CONDUTTIVO

SISTEMA DI CONTROLLO

CONSOLE

APPALTATORE

BANCONE

CONTROLLO

NASTRO TRASPORTATORE

GRUPPO ESTRAIBILE

ANIDRIDE CARBONICA

PILASTRO; COLLETTORE

COMUNE, COMUNICAZIONE, COMMINATORIE

COMBUSTIONE; COMBINATO

COMUNICAZIONE

COMPATTATO

COMPARTIMENTO

FOGNA COMBINATA

CONCENTRICO; CALCESTRUZZO

CONNESSIONE (CONNETTORE)

COSTRUZIONE

CONTINUAZIONE; CONTINUO; CONTINUARE

APPALTATORE

REFRIGERATORE AD EVAPORAZIONE.

CORRIDOIO

COPERTINA

PANNELLO DI CONTROLLO

COMPRESSIBILI

COMPUTER

RELE' DI COMANDO;RELE' DI CORRENTE

TAPPETO; TRASFORMATORE DI POTENZA DI

CONTROLLO;COMPATTATORE ( RETI, ECC.).

CONDENSATORE; CAPACITA'

BULLONE CARROZZA; POZZETTO DI RACCOLTA;

INTERRUTORE DI CORRENTE

CILINDRO DI CALIBRAZIONE

ACQUA DI RAFFREDDAMENTO A CIRCUITO CHIUSO

CICLO DI ALIMENTAZIONE CHIMICA

PULIZIA CONDENSATORE

BINARIO PER PARTIZIONI

TELEVISIONE A CIRCUITO CHIUSO

TRASFORMATORE DI TENSIONE CAPACITIVO

ABBREVIAZIONI

AB

BR

EV

IA

ZI

O

NI

- P

AG

IN

A

POSTAZIONE DI INIZIO TANGENTE

VERTICALE-INTERCETTA DELLA CURVA

MANDATA DELL'ACQUA IN CIRCOLO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

NO SCALE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

KMS

/1

/2

:0 :4

A

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \D

R A

W

IN

G

IN

D E

X C

O M

P O

S

IT

E B

L D

C R b g ro th e .r v t

A B

B R

E V

IA

T

IO

N

S

S H

E E

T

GI030

BKG JMK BAG

G I0

A

B B

R E

V

IA

T

IO

N S

S

H E

E T

14121418 4 429

ABBREVIATIONS

vv TERM

CLOS CLOSURE

CLR CLEAR(ANCE)

CLS CHLORINE SOLUTION; CONTROL CONSOLE OR

PANEL

CLV CHLORINE VACUUM

CLW CHLORINE WATER

CLWG CLEAR WIRED GLASS

cm CENTIMETER(S)

CMH CUBIC METER PER HOUR

CMP CORRUGATED METAL PIPE; COMPRESSOR

CMPST COMPOSITE

CMU CONCRETE MASONRY UNIT

CMW COMMAND MILITARY WORKS

CND CONDUIT, CONDENSATE, CONDENSOR

CNR CONDUCTIVE NEOPRENE LATEX

CNS CONTROL SYSTEM

CNSL CONSOLE

CNTOR CONTACTOR

CNTR COUNTER

CNTRL CONTROL

CNV, CNVR CONVEYOR

CO CLEANOUT

CO2 CARBON DIOXIDE (SYSTEM)

COL COLUMN; COLLECTOR

COM COMMON, COMMUNICATION, COMMINUTOR

COMB COMBUSTION, COMBINATION

COMM COMMUNICATION

COMP COMPACTED

COMPT COMPARTMENT

COMS COMBINATION SEWER

CONC CONCENTRIC; CONCRETE

CONN CONNECT(ION) (OR)

CONST CONSTRUCTION

CONT CONTINUATION; CONTINUOUS; CONTINUE

CONTR CONTRACTOR

COOL EVAPORATIVE COOLER

CORR CORRIDOR

COV COVER

CP, CPNL CONTROL PANEL

CPRS COMPRESSIBLE

CPT CARPET; CONTROL POWER TRANSFORMER;

COMPACTOR (SCREENINGS, ETC)

CPU COMPUTER

CR CONTROL RELAY; CURRENT RELAY

vv TERM

CE COVER ELEVATION

CEB CONCRETE EQUIPMENT BASE

CEM CEMENT

CEM PLAS CEMENT PLASTER

CEMS CONTROL EMISSIONS MONITORING

CER CERAMIC

CF CHEMICAL FEED SYSTEM

CFI CONDUCTIVE FLOORING

CFLG COUNTERFLASHING

CFM CUBIC FEET PER MINUTE

CFR CHEMICAL FEEDER

CFS CUBIC FEET PER SECOND

CG CORNER GUARD, CEILING GRILLE

CH CHILLER

CH BD CHALKBOARD

CHAN CHANNEL

CHEM CHEMICAL

CHFR CHAMFER

CHGR CHARGER

CHIM CHIMNEY

CHK CHECK

CHKR PL CHECKER PLATE

CHR PL CHROME PLATED

CHS COAL HANDLING SYSTEM

CHWB CHILLED WATER BYPASS

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

CHYO HYDROGEN SYSTEM

CI CAST IRON, CURB INLET

CIP CAST IN PLACE; CAST IRON PIPE; CLEANING PORT

CIRC CIRCULAR

CISP CAST IRON SOIL PIPE

CIWR CIRCULATING WATER RETURN

CIWS CIRCULATING WATER SUPPLY

CJ CONSTRUCTION JOINT

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER

CL CENTERLINE; CLEARANCE; CLOSE

CLAR CLARIFIER

CLF CURRENT LIMITING FUSE

CLG CEILING; COOLING; CHLORINE GAS

CLG HT CEILING HEIGHT

CLGL CLEAR GLASS

CLJ CONTROL JOINT

CLL CONTRACT LIMIT LINE, CHLORINE LIQUID

CLO CLOSET

vv TERM

BRCG BRACING

BRDG BRIDGING

BREAK GRADE BREAK

BRG BEARING

BRG PL BEARING PLATE

BRK BRICK

BRKR BREAKER

BRKT BRACKET

BRN BRINE

BRZ BRONZE

BS BOTH SIDES

BSMT BASEMENT

BT BUFFER TANK

Btu BRITISH THERMAL UNIT

BtuH BTU PER HOUR

BTWN BETWEEN

BUR BUILT-UP ROOFING

BVC BEGIN VERTICAL TANGENT-CURVE INTERSECT

BVCE BEGIN VERTICAL TANGENT-CURVE INTERSECT

ELEVATION

BVCS BEGIN VERTICAL TANGENT-CURVE INTERSECT

STATION

BVP PROFILE START

BW BOTH WAYS

BWR BLOWER

BWWT BACKWASH WATER

C CONDUIT; CELSIUS; CHANNEL; CONCRETE; COIL

C TO C CENTER TO CENTER

C&G CURB AND GUTTER

CA CABLE, COMPRESSED AIR

CAB CABINET

CAEX CONDENSER AIR EXTRACTION

CAP CAPACITOR; CAPACITY

CB CARRIAGE BOLT; CATCH BASIN; CIRCUIT BREAKER

CC CALIBRATION CYLINDER

CCCW CLOSED CYCLE COOLING WATER

CCF CYCLE CHEMICAL FEED

CCLN CONDENSER CLEANING

CCT CUBICLE CURTAIN TRACK

CCTV CLOSED CIRCUIT TELEVISION

CCVT COUPLING CAPACITIVE VOLTAGE TRANSFORMER

CCW COUNTERCLOCKWISE

CD CEILING DIFFUSER

CDMU CYCLE MAKEUP

CDOF CYCLE OVERFLOW

CDRN CHEMICAL DRAIN

vv TERM

BAT BATTEN; BATTERY

BB BULLETIN BOARD, BOILER BLOWDOWN

BC BOOKCASE; BETWEEN CENTERS; BOLT CIRCLE;

BOTTOM CHORD; BUILDING CODE; CURVE

BEGINNING

BCA BOILER COMBUSTION AIR

BCF BOILER - COAL FIRED

BCND BUILDING HEATING CONDENSATE

BD BOARD

BDRY BOUNDARY

BEJ BRICK EXPANSION JOINT

BEV BEVEL

BF BOTH FACES

BFF BELOW FINISH FLOOR

BFP BACK FLOW PREVENTER

BFU BOILER FEEDWATER UNIT

BFW BOILER FEEDWATER

BGAS BUTANE GAS

BGF BOILER GAS FIRED

BGH BAGHOUSE

BHS BUILDING HEATING STEAM

BITUM BITUMINOUS

BJT BED JOINT

BKR BREAKER

BL BASELINE, BUILDING LINE

BLD BOILER DRAINS

BLDG BUILDING

BLR BOILER

BLS BALLAST

BLVT BOILER VENTS

BLW BELOW

BM BEAM(S); BENCHMARK; BENDING MOMENT

BNDG BONDING

BNR BURNER (WASTE GAS, INCINERATOR, ETC)

BO BOTTOM OF

BOA BEGIN OF ALIGNMENT

BOC BACK OF CURB

BOD BOTTOM OF DUCT

BOF BOTTOM OF FOOTING

BOG BOTTOM OF GIRT

BOS BOTTOM OF STEEL

BOT BOTTOM

BOTR BOTTOM OF TRENCH

BOX HVAC BOX (MIXING, REHEAT, VARIABLE VOLUME)

BP BACK PLASTER(ED), BEGINNING POINT,

ALIGNMENT BEGINNING POINT

BPCV BACK PRESSURE CONTROL VALVE

vv TERM

AHR ANCHOR

AHU AIR HANDLING UNIT

AI AREA INLET, ANALOG INPUT

AIC AMPERE INTERRUPTING CURRENT (CAPACITY)

AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION

AL ACTIVE LEAF, ALUMINUM

ALT ALTERNATE; ALTITUDE

ALUM ALUMINUM

AMB AMBIENT

AMP AMPERE

AMT AMOUNT

AND ANODE

ANN ANNUNCIATOR

ANOD ANODIZE

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

ANT ANTENNA

AO ANALOG OUTPUT

APPROX APPROXIMATE

APU AUXILIARY POWER UNIT

APVD APPROVED

ARCH ARCHITECTURE; ARCHITECTURAL

ARI AMERICAN REFRIGERATION INSTITUTE

ARV AIR RELEASE VALVE

AS AIR SEPARATOR, AIR SUPPLY

ASB ASBESTOS

ASC ABOVE SUSPENDED CEILING; ADJUSTABLE SPEED

CONTROLLER (ELECTRONIC)

ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS

ASD ADJUSTABLE SPEED DRIVE (MECHANICAL)

ASPH ASPHALT

ASSY ASSEMBLY

ASTM AMERICAN SOCIETY FOR TESTING MATERIALS

AT AMPERE TRIP

ATC ACOUSTICAL TILE CEILING

ATFP ANTI-TERRORISM FORCE PROTECTION

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AVB ACTIVE VEHICLE BARRIER

AVG AVERAGE

AWG AMERICAN WIRE GAUGE

AWT ACOUSTICAL WALL TREATMENT

AXCW AUXILIARY COOLING WATER

AXS AUXILIARY STEAM

B PL BASE PLATE

B/B BACK TO BACK

vv TERM

A AMPERE; GRADE CHANGE; AERATOR

A/C ACCESS CONTROL; AIR CONDITION(ING)

A/C UNIT AIR CONDITIONING UNIT

AA ADHESIVE ANCHOR

AB ANCHOR BOLT(S)

ABA ARCHITECTURAL BARRIERS ACT

ABC AGGREGATE BASE COURSE

ABV ABOVE

AC ACRE; ALTERNATING CURRENT; ACID

ACB AIR CIRCUIT BREAKER

ACC ACCESSIBLE

ACCU AIR COOLED CONDENSING UNIT

ACCUR ACCURATE

ACI AMERICAN CONCRETE INSTITUTE

ACP ACCESS CONTROL POINT

ACS ASH COLLECTION SYSTEM

ACS DR ACCESS DOOR

ACS PNL ACCESS PANEL

ACSR ALUMINUM CABLE STEEL REINFORCED

ACST ACOUSTIC

ACT ACOUSTICAL CEILING TILE

ACU AIR CONDITIONING UNIT

ACV AUTOMATIC CONTROL VALVE

ACV-3 3 WAY AUTOMATIC CONTROL VALVE

ACVT ACID VENT

ACWD ACID WASTE DRAIN

AD ACCESS DOOR, AIR DRYER

ADA AMERICAN DISABILITIES ACT

ADDC ABU DHABI DISTRIBUTION COMPANY

ADDL ADDITIONAL

ADDM ADDENDUM

ADH ADHESIVE

ADJ ADJACENT; ADJOINING; ADJUST(ABLE)

ADN AREA DISTRIBUTION NODE

ADO AUTOMATIC DOOR OPERATOR

AEAR AERATION AIR

AF AMPERE FRAME; AUDIO FREQUENCY; FLAME

ARRESTOR

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISH(ED) GRADE

AFIL AIR FILTER (VENTILATION AND AIR CONDITIONING

ONLY)

AGAR AGITATION AIR

AGE AIRCRAFT GROUND EQUIPMENT

AGGR AGGREGATE

AGM ARRESTING GEAR MARKER

AH AMPERE HOUR

AHC AIR HEATING COIL

GENERAL NOTES

1. ALL ABBREVIATIONS SHOWN ON THIS LEGEND MAY NOT APPEAR

ON THIS SET OF DRAWINGS.

TUTTE LE ABBREVIAZIONI INCLUSE IN QUESTA LEGENDA POSSONO

NON APPARIRE IN QUESTA SERIE DI DISEGNI

FILTRARE

FLUORESCENTE

RECINZIONE

MOLA APERTA, FIBRA OTTICA, OLIO COMBUSTIBILE

CONDOTTO DI METALLO FLASSIBILE

AB

BR

EV

IA

ZI

O

NI

PA

G

IN

A

FORZA PRINCIPALE

FLESSIBILE

PAVIMENTAZIONE, FLANGIA/E

PIASTRA DA PAVIMENTO

PAVIMENTAZIONE

CONDIZIONATORE STANZA COMPUTER

CIRCONFERENZA

GRANA IRREGOLARE

ACCIAIO RESISTENTE ALLA CORROSIONE

GRU

INDICATORE DI GUASTO

UNITA' DI RITORNO DELLA CONDENSA

TUBO CATODICO

SPIRALE COMPOSTA DA PICCOLO RAGGIO ALL'ESTREMITA'

SISTEMA DI RACCOLTA - CENERE

INTELAIATURA

SVASATURA

CABINA COMPATTA

PIASTRELLE DI CERAMICA, TRASFORMATORE DI CORRENTE

CENTRO

CENTRIFUGA

CONTROLLO

TELEVISIONE VIA CAVO

CENTRIMETRI CUBI

TORRE DI RAFFREDDAMENTO

PIEDI CUBI

POLLICI CUBI

MILLIMETRI CUBI

METRI CUBI

IARDE CUBICHE

UNITA' DI CONDENSAZIONE, RAME

CONVETTORE

CABINA ELETTRICA

CANALE SOTTERRANEO

BOX A VOLUME COSTANTE

SFIATO CHIMICO

ACQUA FREDDA

ALIMENTAZIONE CHIMICA DELL'ACQUA IN CIRCOLO

BYPASS DELL'ACQUA DEL CONDENSATORE

POMPA DELL'ACQUA IN CIRCOLAZIONE

RITORNO DELL'ACQUA DI CONDENSA

FORNITURA DELL'ACQUA DI CONDENSA

SFIATO A SOFFITTO, VALVOLA DI NON RITORNO CON

TASSO CONTROLLORE DI FLUSSO

VINILICO CONDUTTIVO OMOGENEO

(DISEGNO TIPO)

PIETRA FUSA; STAZIONE DI CONTROLLO LOCALE;

INTERSEZIONE CURVA-SPIRALE; FANGO CIRCOLANTE.

SPIRALE COMPOSTA DA GRANDE RAGGIO ALL'INIZIO

SPIRALE COMPOSTA DA GRANDE RAGGIO ALL'ESTREMITA'

SPIRALE COMPOSTA DA PICCOLO RAGGIO ALL'INIZIO

ACQUA DI CITTA'

CILINDRO (IDRAULICO, PNEUMATICO, ECC.)

VALVOLA DI SCARICO

PROFONDITA' PENNY (AS IN NAIL - 10d)

SISTEMA DI ANTENNE DISTRIBUITE;

SISTEMA DI ACQUISIZIONE DATI

DATO

LAMPADINA A SECCO, CAVIDOTTO

DOPPIO

PORTA DOPPIA ATTIVA

MISURAZIONE DI DECIBEL

CORRENTE DIRETTA

GIUNTO DI CONTROLLO A PERNO

GIUNTO DI RITIRO

INDICATORE DI GUASTO

ACQUA FREDDA DOMESTICA

SISTEMA DI CONTROLLO DIGITALE DIRETTO

DISAERATORE

GRADI

DEUMIDIFICAZIONE

DEMOLIZIONE

DEPRESSIONE

DIPARTIMENTO

DETTAGLIO

FONTANELLA

COPERTURA GALLEGGIANTE DEL DIGESTORE

GENERATORE ALIMENTATO A

DIESEL

DIGESTORE GAS

DOPPIA ANTA, RISCALDATORE A CONDOTTA

ACQUA DOMESTICA CALDA

RICIRCOLO DELL'ACQUA CALDA DOMESTICA

INPUT DIGITALE; FERRO DUTTILE

DIAMETRO

DIAGONALE

DIFFUSORE

DIMENSIONI

TUBAZIONE IN FERRO DUTTILE

DISTRIBUTORE

DISCONNESSIONE

DISPENSER

DISTANZA

DISTRIBUZIONE

PANNELLO DI DISTRIBUZIONE

DIVISIONE

DEIONIZZAZIONE DELL'ACQUA

FORNITURA ACQUA DEIONIZZATA

CARICO MORTO

DEALKALIZER

AUTOCARRO

MISURATORE DI DOMANDA

IMPERMEABILIZZAZIONE

SMONTABILE

SBRINATORE

OUTPUT DIGITALE: IDEM

GIU'

PROGETTISTA

PROFONDITÀ'

DIPARTIMENTO DEI TRASPORTI

DOPPIO POLO, SINGOLA VIA

DOPPIO POLO, DOPPIA VIA

TRASMETTITORE DI PRESSIONE DIFFERENZIATA

CHIUSURA PORTA

PORTA, DRENAGGIO

DRENAGGIO

GOCCIOLATOIO

TRASMISSIONE

VETRO A DOPPIA FORZA, PLUVIALE,

FANGHI DIGERITI, DISCONNESSO

ASCIUGATORE

PIASTRELLA DRENANTE

UNITA' DI AZIONAMENTO

DISEGNI

INCASTRO A CODA DI RONDINE

INDICATORE DI GUASTO

DISEGNATORE

MONTACARICHI, DEMINERALIZZATORE DI ACQUA

ESPANSIONE DIRETTA

INDICATORE DI GUASTO

EST, ELETTRICO

OGNI, ARIA DI SCARICO

TEMPERATURA DI ARIA IN ENTRATA

MOTORE - MODULO SOFFIAGGIO

AFFLUENTE DEL BACINO DI EQUALIZZAZIONE

ECONOMIZZATORE

FINE CURVA

PROTEZIONE CATODICA

INDICATORE DI GUASTO

POTENZA IN CORRENTE CONTINUA

ATTREZZATURA DEL SISTEMA DI DRENAGGIO

ALIMENTAZIONE ELETTRICA DI EMERGENZA

EDUCATORE

LAVAGGIO OCCHI DI EMERGENZA

SU DUE LATI, VENTILATORE PER LA RIPRESA D'ARIA

TERRA ESISTENTE, GRIGLIA DI SCARICO, MOTORE

GENERATORE, GENERAZIONE ELETTRICA

TRACCIA TERMICA ELETTRICA

GIUNTO DI ESPANSIONE

PROSPETTO - GRADO O EDILIZIA, VARIE POTENZA

INFERIORE O UGUALE A 240V.

ELETTRICO

MONTACARICHI

METALLO ESPANSO, VARIE POTENZE MAGGIORE DI

240V E MENO DI O UGUALE A 600V.

INCASSO

DOMANDA MASSIMA DI STIMA

EMERGENZA

POZZETTO ELETTRICO

SISTEMA DI GESTIONE ENERGIA

RECINZIONE

TUBAZIONE METALLICA ELETTRICA

ENTRATA

MOTORE

FINE ALLINEAMENTO

MEMBRANA PER TETTO IN PROPILENE -DIENE-

MONOMERO.

QUADRO ELETTRICO, PUNTO FINALE, A PROVA DI

ESPLOSIONE.

STAZIONE/INTERRUTTORE DI SPEGNIMENTO DI EMERGENZA

SISTEMA A RELÈ DI PROTEZIONE

EVAPORATORE

A PROVA DI ESPLOSIONE

RIVESTIMENTO EPOSSIDICO

EQUIDISTANTE

UGUALE

ATTRAZZATURA

ATTREZZATURA

STIMA

VASO DI ESPANSIONE, MAGGIORE DI 26KV DI

POTENZA

ESISTENTE DA RIMANERE

ECCETERA

RISCALDATORE ELETTRICO

GRUPPO DI CONTINUITÀ'

COMANDO DI EMERGENZA, POTENZA 2.4, 4.16 O

7.2KV.

ALIMENTAZIONE ELETTRICA, POTENZA 12.47,

13.2 O 13.8KV.

SCALA MOBILE

VALVOLA DI INTERCETTAZIONE DI EMERGENZA,

EMERGENZA SPEGNIMENTO

ESTREMITÀ VERTICALE CURVA-TANGENTE

INTERSEZIONE

FINE PROFILO

BOCCHETTA DELL'APPARECCHIATURA

OGNI MODO

REFRIGERATORE D'ACQUA ELETTRICO

STAZIONE DI LAVORO DI INGEGNERIA

SCALDABAGNO

LAVAOCCHI/DOCCETTA DI SICUREZZA

TEMPERATURA DELL'ACQUA IN ENTRATA

ACQUA DI SCARICO

SCAVO; ECCITATORE

CONDOTTO DI SCARICO

GRIGLIA DI SCARICO

ARIA DI SCARICO

SCARICO; CAPPA DI ASPIRAZIONE

ESPANSIONE, ESPOSTO

BULLONE DI ESPANSIONE

ESISTENTE

ESTENSIONE, ESTERNO

DRENAGGIO DI ESTRAZIONE

VAPORE DI ESTRAZIONE

MATTONE REFRATTARIO

FAHRENHEIT

SERRANDA TAGLIAFUOCO

FREQUENZA DI CORRENTE

ALLARME ANTINCENDIO, PRESA D'ARIA

ARMADIETTO ANTINCENDIO

CENTRALE ANTINCENDIO

GRIGLIA PRESA D'ARIA

FOOT CANDLE, MOLLA CHIUSA

VENTILATORE

MATTONE A VISTA

RIVESTIMENTO

GIUNTO DI COSTRUZIONE DEL PAVIMENTO

PULIZIA DEL PAVIMENTO

SOLUZIONE PER IL CONTROLLO DELLA SCHIUMA

VENTILCONVETTORE

CICLO DELL'ACQUA DI SCARICO

VALVOLA DI CONTROLLO DEL FLUSSO

SERRANDA TAGLIAFUOCO, SCARICO A PAVIMENTO

RILEVATORE DI CALORE O DI FUOCO

ATTACCO RETE SERVIZIO ANTINCENDIO

VENTILATORE, TIRAGGIO FORZATO

SERRANDA TAGLIAFUOCO

FINE STAZIONE DI INTERSEZIONE CURVA-TANGENTE

VERTICALE

FINE PROSPETTO DI INTERSEZIONE CURVA -

TANGENTE VERTICALE

ESTINTORE; EFFETTO FINALE; ELEMENTO DI FLUSSO

FONDAZIONE

SERRANDA TAGLIAFUOCO

ALIMENTATORE

STAFFA ESTINTORE

ARMADIETTO ESTINTORE

INDICATORE DI GUASTO

VENTILATORE, PROGETTO INDOTTO

PROSPETTO FINITURA PAVIMENTO

GRADO FINITO, GAS COMBUSTIBILE

FIBRA DI VETRO

RICIRCOLO DEI GAS COMBUSTIBILI

IDRANTE, TESTA FLANGIATA

ARMADIETTO PORTA TUBI ANTINCENDIO

VITE A TESTA PIATTA

RACK PORTATUBO ANTINCENDIO

STAZIONE ANTINCENDIO

SFIATI E SCARICHI DEL RISCALDATORE DELL'ACQUA

DI ALIMENTAZIONE

VITE PER LEGNO A TESTA PIATTA

INDICATORE DI FLUSSO

VENTILATORE, PROGETTO INDOTTO

FIGURA

FILTRO

FINITURA

PAVIMENTO FINITO

TUBO DI FERRO FEMMINA, FALLITO SUL POSTO

FISSAGGIO

GIUNTO A FILO

PAVIMENTAZIONE; LINEA DI FLUSSO

AMPERE A PIENO CARICO

SCOSSALINA

FLOCCULATORE

- ABBREVIAZIONI

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

DRAWFORM REVISION: 10 MARCH 2009

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

V Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

A

T L A

N T

IC

N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M C

O M

M A

N D

N O

R F

O L

K V

A

A V

IA

N

O A

IR

B

A S

E A

V

IA

N O

IT

A L Y

P -0

E

D I-

R A

D R

S T

O R

A G

E F

A C

IL

IT

Y

DESIGN DIRECTOR

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE: 04 AUGUST 2022

RICHARD STEPHENS, PE

NO SCALE

225 Iowa Avenue, Muscatine, Iowa 52761-3764 www.stanleyconsultants.com

FIRE PROTECTION

LET/LRP

A T

L A

N T

IC

D

E S

IG

N

A N

D C

O N

S T

R U

C T

IO

N

UNCLASSIFIED

UNCLASSIFIED

U N

C L A

S S

IF

IE

D

P

LO

T T

E D

N6247022R3000

DPS

A

B

C

D

Approved by Allan Lucht, via Email.

KMS

/1

/2

:0 :5

A

M C

R

E V

IT

P

R O

J E

C T

F

IL

E

S \D

R A

W

IN

G

IN

D E

X C

O M

P O

S

IT

E B

L D

C R b g ro th e .r v t

A B

B R

E V

IA

T

IO

N

S

S H

E E

T

GI031

BKG BAG BAG

G I0

A

B B

R E

V

IA

T

IO

N S

S

H E

E T

14121419 5 429

ABBREVIATIONS

GENERAL NOTES

1. ALL ABBREVIATIONS SHOWN ON THIS LEGEND MAY NOT APPEAR

ON THIS SET OF DRAWINGS.

ABBREV TERM

FDN FOUNDATION

FDP FIRE DAMPER

FDR FEEDER

FE FIRE EXTINGUISHER; FINAL EFFLUENT; FLOW

ELEMENT

FEB FIRE EXTINGUISHER BRACKET

FEC FIRE EXTINGUISHER CABINET

FF FACTORY FINISH, FINISH FLOOR, FAR FACE

FFD FAN, FORCED DRAFT

FFE FINISH FLOOR ELEVATION

FG FINISHED GRADE, FUEL GAS

FGL FIBERGLASS

FGR FUEL GAS RECIRCULATION

FH FIRE HYDRANT, FLATE HEAD

FHC FIRE HOSE CABINET

FHMS FLAT HEAD MACHINE SCREW

FHR FIRE HOSE RACK

FHS FIRE HOSE STATION

FHTD FEEDWATER HEATER VENTS AND DRAINS

FHWS FLAT HEAD WOOD SCREW

FI FLOW INDICATOR

FID FAN, INDUCED DRAFT

FIG FIGURE

FIL FILTER

FIN FINISH

FIN FLR FINISH(ED) FLOOR

FIP FEMALE IRON PIPE, FAIL IN PLACE

FIXT FIXTURE

FJT FLUSH JOINT

FL FAIL LAST; FLOOR; FLOW LINE

FLA FULL LOAD AMPS

FLASH FLASHING

FLC FLOCCULATOR

FLEX FLEXIBLE

FLG FLOORING, FLANGE(S)

FLR FLOOR

FLR PL FLOOR PLATE

FLT FILTRATE

FLUOR FLUORESCENT

FM FORCE MAIN

FMC FLEXIBLE METAL CONDUIT

FN FENCE

FO FAIL OPEN; FIBER OPTIC, FUEL OIL

ABBREV TERM

EVCE END VERTICAL CURVE-TANGENT INTERSECT

STATION

EVCS END VERTICAL CURVE-TANGENT INTERSECT

ELEVATION

EVP PROFILE END

EVT EQUIPMENT VENT

EW EACH WAY

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EWS ENGINEERING WORK STATION

EWSS EYEWASH/SAFETY SHOWER

EWT ENTERING WATER TEMPERATURE

EWTR EFFLUENT WATER

EXC EXCAVATE; EXCITER

EXD EXHAUST DUCT

EXG EXHAUST GRILLE

EXH EXHAUST; EXHAUST HOOD

EXH A EXHAUST AIR

EXP EXPANSION, EXPOSED

EXP BT EXPANSION BOLT

EXST EXISTING

EXT EXTENSION; EXTERIOR

EXTD EXTRACTION DRAINS

EXTS EXTRACTION STEAM

F FAHRENHEIT

F BRK FIRE BRICK

F.D. FIRE DAMPER

F/I FREQUENCY TO CURRENT

FA FIRE ALARM, FRESH AIR

FAC FIRE APPARATUS CLOSET

FACP FIRE ALARM CONTROL PANEL

FAI FRESH AIR INTAKE

FAN FAN OR BLOWER

FC FOOT CANDLE, FAIL CLOSED

FC BRK FACE BRICK

FCG FACING

FCJ FLOOR CONSTRUCTION JOINT

FCO FLOOR CLEANOUT

FCS FOAM CONTROL SOLUTION

FCU FAN COIL UNIT

FCV FLOW CONTROL VALVE

FCYD FEEDWATER CYCLE DRAINS

FD FIRE DAMPER; FLOOR DRAIN; FIRE OR HEAT

DETECTOR

FDC FIRE DEPARTMENT CONNECTION

FDF FAN, FORCED DRAFT

FDMPR FIRE DAMPER

ABBREV TERM

EG EXISTING GROUND, EXHAUST GRILLE, ENGINE

GENERATOR, ELECTRICAL GENERATION

EHT ELECTRICAL HEAT TRACE

EJ EXPANSION JOINT

EL ELEVATION - GRADE OR BUILDING,

MISCELLANEOUS POWER LESS THAN OR EQUAL

TO 240V

ELEC ELECTRIC(AL)

ELV, ELEV ELEVATOR

EM EXPANDED METAL, MISCELLANEOUS POWER

GREATER THAN 240V AND LESS THAN OR EQUAL

TO 600V

EMBED EMBEDMENT

EMD ESTIMATED MAXIMUM DEMAND

EMER EMERGENCY

EMH ELECTRICAL MANHOLE

EMS ENERGY MANAGEMENT SYSTEM

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSE(URE)

ENG ENGINE

ENTR ENTRANCE, ENTERING

EOA END OF ALIGNMENT

EP ELECTRICAL PANELBOARD, END POINT,

EXPLOSION PROOF

EPDM PROPYLENE-DIENE-MONOMER ROOF MEMBRANE

EPDS EMERGENCY POWER DOWN STATION/SWITCH

EPM PROTECTIVE RELAY SYSTEM

EPR EVAPORATOR

EPRF EXPLOSION PROOF

EPY EPOXY COATING

EQ EQUAL

EQL SP EQUALLY SPACED

EQPT EQUIPMENT

EQUIP EQUIPMENT

ER EMERGENCY REMOTE, 2.4, 4.16 OR 7.2KV POWER

ES ELECTRICAL SUPPLY, 12.47, 13.2 OR 13.8KV POER

ESCAL ESCALATOR

ESO EMERGENCY SHUT-OFF VALVE, EMERGENCY

SHUTDOWN

EST ESTIMATE(D)

ET EXPANSION TANK, GREATER THAN 26KV POWER

ETC ET CETERA

ETR EXISTING TO REMAIN

EUH ELECTRIC UNIT HEATER

EUPS UNINTERRUPTIBLE POWER SUPPLY

EVC END VERTICAL CURVE-TANGENT INTERSECT

ABBREV TERM

DL DEAD LOAD

DLK DEALKALIZER

DM DEMAND METER

DMP, DMPR DAMPER

DMPF DAMPPROOFING

DMST DEMISTER

DMT DEMOUNTABLE

DN DOWN

DO DIGITAL OUTPUT; DITTO

DOR DESIGNER OF RECORD

DOT DEPARTMENT OF TRANSPORTATION

DP DEPTH

DPDT DOUBLE POLE, DOUBLE THROW

DPST DOUBLE POLE, SINGLE THROW

DPT DIFFERENTIAL PRESSURE TRANSMITTER

DR DOOR, DRAIN

DR CL DOOR CLOSER

DRB DRAINBOARD

DRN DRAIN

DRV DRIVE

DRY AIR DRYER

DS DOUBLE STRENGTH (GLASS), DOWNSPOUT,

DIGESTED SLUDGE, DISCONNECT

DT DRAIN TILE

DU DRIVE UNIT

DVTL DOVETAIL

DWG DRAWING(S)

DWLS DOWELS

DWR DRAWER

DWTR DUMBWAITER, DEMINERALIZER WATER

DX DIRECT EXPANSION

E EAST, EASTING, ELECTRICAL

E-E EDGE TO EDGE

EA EACH, EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EB ENGINE - BLOWER MODULE

EBE EQUALIZATION BASIN EFFLUENT

EC CURVE END

ECO ECONOMIZER

ECP CATHODIC PROTECTION

ED EQUIPMENT DRAIN

EDC DIRECT CURRENT POWER

EDRN EQUIPMENT DRAIN SYSTEM

EDU EDUCATOR

EEP ELECTRICAL EMERGENCY POWER

EEW EMERGENCY EYE WASH

EF EACH FACE, EXHAUST FAN

ABBREV TERM

CWTR CITY WATER

CYL CYLINDER (HYDRAULIC, PNEUMATIC, ETC)

D, d DEEP, PENNY (AS IN NAIL - 10d)

D/FV DEFUEL/FLUSH VALVE

DAS DISTRIBUTED ANTENNA SYSTEM; DATA

ACQUISITION SYSTEM

DAT DATUM

DB DRY BULB, DUCT BANK

DBL DOUBLE

DBL ACT DR DOUBLE ACTING DOOR

DBM DECIBEL METER

DC DIRECT CURRENT

DCJ DOWELED CONTROL JOINT

DCJT DUMMY CONTROL JOINT

DCS DISTRIBUTED CONTROL SYSTEM

DCW DOMESTIC COLD WATER

DDC DIRECT DIGITAL CONTROLS (SYSTEM)

DEA DEAERATOR

DEG DEGREE(S)

DEH DEHUMIDIFIER

DEMO DEMOLITION

DEPR DEPRESSION

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DFC DIGESTER FLOATING COVER

DG DIESEL GENERATOR

DGB DIGESTER GAS BOOSTER

DH DOUBLE HUNG, DUCT HEATER

DHW DOMESTIC HOT WATER

DHWR DOMESTIC HOT WATER RECIRCULATION

DI DIGITAL INPUT; DUCTILE IRON

DIA DIAMETER

DIAG DIAGONAL

DIFF DIFFUSER

DIM DIMENSION(S)

DIP DUCTILE IRON PIPE

DIS DISTRIBUTOR (EDUCATOR, EJECTOR, ETC)

DISC DISCONNECT

DISP DISPENSER

DIST DISTANCE

DISTR DISTRIBUTION

DISTR PNL DISTRIBUTION PANEL

DIV DIVISION

DIWR DEIONIZED WATER RETURN

DIWS DEIONOZED WATER SUPPLY

ABBREV TERM

CRAC COMPUTER ROOM AIR CONDITIONER

CRCMF CIRCUMFERENCE

CRES CORROSIVE RESISTANT STEEL

CRG CROSS GRAIN

CRN CRANE

CRS COURSE(S), COLD REHEAT STEAM

CRT CATHODE RAY TUBE

CRU CONDENSATE RETURN UNIT

CS CAST STONE; LOCAL CONTROL STATION;

CURVE-SPIRAL INTERSECT; CIRCULATING SLUDGE

CS_LRB COMPOUND SPIRAL LARGE RADIUS AT BEGINNING

CS_LRE COMPOUND SPIRAL LARGE RADIUS AT END

CS_SRB COMPOUND SPIRAL SMALL RADIUS AT BEGINNING

CS_SRE COMPOUND SPIRAL SMALL RADIUS AT END

CSA COLLECTION SYSTEM - ASH

CSK COUNTERSUNK

CSMT CASEMENT

CSS COMPACT SUBSTATION

CT CERAMIC TILE, CURRENT TRANSFORMER

CTF CENTRIFUGE

CTR CENTER

CTRL CONTROL

CTV CABLE TELEVISION

CTWR COOLING TOWER

CU CM CUBIC CENTIMETER

CU FT CUBIC FEET

CU IN CUBIC INCH

CU M CUBIC METER

CU MM CUBIC MILLIMETER

CU YD CUBIC YARDS

CU, Cu…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .