Technical Amendment 0006 is a document updating the drawing for the P-7889 Dental Clinic Replacement project at Marine Corps Recruit Depot Parris Island, South Carolina. The amendment, dated 03/24/25, specifically revises the Second Floor Pressure Piping Plan for Block 2G, identified by NAVFAC drawing number 12909202 on sheet PP217. The drawing provides detailed piping layout and specifications for the second floor of the dental clinic, including pipe sizes, routing instructions, and room designations. A key note on the drawing instructs contractors not to route plumbing piping through elevator shafts, stairwells, data, and electrical rooms.
The technical amendment is part of the larger dental clinic replacement project, which involves constructing a new facility to support recruits and active-duty members. The project includes utilities, district steam system connections, special foundations, site improvements, parking, signage, antiterrorism/force protection measures, and environmental protections. The new facility will be elevated to protect against flooding, and the existing Dental Clinic building 674 and Pass and Identification building 602 will be demolished as part of the overall project scope.
View the file
Other files
Show 40 more
Latest 50 of 63 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL AMENDMENT 0006
NAVFAC ATLANTIC
CONTINUATION SHEET
SECTION 00 01 15 LIST OF DRAWINGS
The following Ambulatory Care Center drawing is revised as of 03/24/25: This revised drawing accompanies this amendment.
NAVFAC DWG NO. SHEET NO. TITLE
12909202 PP217 SECOND FLOOR PRESSURE PIPING PLAN – BLOCK 2G
-- End of Technical Amendment 0006 --
B B.9 C C.9 D
6.2
5.6
LOUNGE
2G02
NIMITZ
2G03c
ST TLT
2G01
CORRIDOR
2GC1
STAIR
2AS1
CORRIDOR
2AC1
SCRUB ALC
2A05CF LOCKERS
2A05
CORRIDOR
2GC2
COMM RM
2H15
DTR-ENDO
2H02
DTR-ENDO
2H01
EWC-1
L-1
S-1
D0680
D0680
3" 2" 2"
3"
2"
2"
3"
1/ 2"
2"
1/
4"
1/ 4"
1/ 2"
1 1/4" 1 1/4"
1 1/4"3"
WC-1
3" 2 1/2"
2"
1/ 2"
1/ 2"
1/ 2"
2" 3/ 4"
3"
2"
2"
1"
1/ 4"
2"
MATCHLINE: 2G
MATCHLINE: 2A
M A
T C
H
LI
N E
: 2 G
M A
T C
H
LI
N E
: 2 H
DO NOT ROUTE PLUMBING
PIPING THROUGH ELEVATOR
SHAFTS, STAIRWELLS, DATA,
AND ELECTRICAL ROOMS. (TYP.)
DTR-OH
2B02
0.50 GPM
0.50 GPM
0.50 GPM
SOMERSET
2G03a
SEAWOLF
2G03b
A
A
A A
A
A
1 1/2" 1 1/2"
3/4" 1 1/4"
A
A
1/
4"
1/ 4"
D0680
P8711
P8711
PLAN
NORTH
2A
2C 2F
2G 2J
2L 2H
2B
2K
2D 132 133
134 135 136
140139138
SECOND FLOOR KEY PLAN
A
B
C
D
1 2 3 4
1 2 3 4
A
B
C
D
SCALE:
PROJECT NO:
CONSTR CONTR NO:
NAVFAC DRAWING NO:
SHEET: OF
FIRE PROTECTION
CHIEF ENG/ARCH
BRANCH MGR
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
08/19/2024
2' 4' 8'
SCALE: 1/4"=1'-0"
P A
R R
IS
I S
L A
N D
S
C M
C R
D
P A
R R
IS
I S
L A
N D
N A
V A
L S
T A
T
IO
N
N O
R F
O L
K V
A
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
M
ID
L A
N T
D C
C O
R E
MT / SVR
EJA
DSN
Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024
/2
/2
:1
:1
P M
C
U s e rs \c h ri s .e v e rs o le
\D o c u m e n ts \2
P c e v e rs o le
.r v t
1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
PP217
P-7889
D E
N T
A L
C L
IN
IC
R E
P L
A C
E M
E N
T
S E
C O
N D
F L O
O R
P R
E S
S U
R E
P
IP
IN
G
P L A
N
B L O
C K
G
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
M
ID
-A T
L A
N T
IC
12909202
WET WET CLE
SECOND FLOOR PRESSURE PIPING
PLAN - BLOCK 2G
GCM
GENERAL SHEET NOTE:
1. SEE MG SHEETS FOR NG PIPING
A m e n d m e n t N o
/2 /2
| TECHNICAL AMENDMENT NO. 0006 |
| PP217 - SECOND FLOOR PRESSURE PIPING PLAN - BLOCK 2G |
File details come from the government source that posted it. Updated .