1686626dwg08of14_PLUMBING.pdf

PDF 43 MB Posted

Attached to
P-7889 DENTAL CLINIC REPLACEMENT, MARINE CORPS RECRUIT DEPOT PARRIS ISLAND, SC
Solicitation number
N4008525R2500
Issued by

About this file

This file contains plumbing and medical gas system drawings and details for a dental clinic replacement project at Marine Corps Recruit Depot Parris Island, SC. The drawings show comprehensive plumbing plans for both floors including waste piping, pressure piping, and medical gas systems. Specific systems detailed include dental air compressors, oral evacuation, dental surgical vacuum, oxygen, nitrous oxide, and treated water systems.

The drawings include detailed floor plans showing pipe routing, equipment locations, valve placements, and connection details. Key equipment specifications are provided for dental air compressors (DAC-1), oral evacuation systems (OE-1 and OE-2), medical gas manifolds, and dental utility connections. Detailed control diagrams and sequences of operation are included for the oral evacuation and dental air systems. The plans require specialized plumbing infrastructure to support dental operatories including amalgam separators, sterilization equipment, and medical gas zone valve boxes. All systems must be installed according to NFPA 99 requirements for medical gas and vacuum systems.

View the file

Other files

File Type Posted
AMD 0010 - WD SC20250008.pdf PDF
N4008525R2500 AMD 0010.pdf PDF
N4008525R2500 AMD 0009.pdf PDF
USMC ESS_Standard Equip List-v6.1.xlsx XLSX spreadsheet
N4008525R2500 AMD 0008.pdf PDF
N4008525R2500 AMD 0007.pdf PDF
AMD 0006 - Technical Amendment 0008 Continuation Sheet.pdf PDF
N4008525R2500 AMD 0006.pdf PDF
AMD 0006 - Technical Amendment 0008.pdf PDF
AMD 0005 - Technical Amendment 0007 Continuation Sheet.pdf PDF
AMD 0005 - 21-54-23019_CP CPT-2-PPD.xls XLS spreadsheet
AMD 0005 - CPT-1_forAPILE.xls XLS spreadsheet
AMD 0005 - 21-54-23019_SP CPT-1-PPD.xls XLS spreadsheet
AMD 0005 - Technical Amendment 0007.pdf PDF
AMD 0005 - 21-54-23019_CP CPT-2-BSC.XLS XLS spreadsheet
AMD 0005 - 21-54-23019_SP CPT-1 - VsResults.xlsx XLSX spreadsheet
N4008525R2500 AMD 0005.pdf PDF
AMD 0005 - 21-54-23019_SP CPT-1-BSC.XLS XLS spreadsheet
AMD 0005 - 21-54-23019 P-7889 Dental Clinic Replacment - Full Report.pdf PDF
N4008525R2500 AMD 0004.pdf PDF
Geo Tech portion P-7889 MCRD PARRIS ISLAND CORRECTED FINAL BASIS OF DESIGN - 26 AUGUST 2024.pdf PDF
674002.PDF PDF
3 of 23 Foundation Plan Building P-88-A (602).pdf PDF
602001.PDF PDF
4 of 23 Foundation Details Building P-88-A (602).pdf PDF
602002.PDF PDF
674001.PDF PDF
602003.PDF PDF
674003.PDF PDF
Technical Amendment 0006 Continuation Sheet.pdf PDF
100 Corrected Final Haz Mat Report B602 and B674 Parris Island - March 2024.pdf PDF
N4008525R2500 AMD 0003.pdf PDF
P7889 VISIT SITE SIGN IN SHEET.pdf PDF
N4008525R2500 AMD 0002.pdf PDF
Technical Amendment 0003.pdf PDF
Technical Amendment 0002.pdf PDF
Attachment C - Price Proposal Form REVISED.docx DOCX document
N4008525R2500 AMD 0001.pdf PDF
Technical Amendment 0004.pdf PDF
Attachment H - Small Business Subcontracting Plan.docx DOCX document
1686626dwg04of14_LANDSCAPE.pdf PDF
1686626dwg11of14_ELECTRICAL.pdf PDF
Attachment D - Construction Experience Data Sheet.docx DOCX document
1686626dwg12of14_AUDIOVISUAL.pdf PDF
Attachment G - Small Business Participation Commitment Document (SBPCD).docx DOCX document
Attachment B - PIEE Vendor Access Instructions.pdf PDF
1686626dwg07of14_GENERAL SERIES.pdf PDF
Attachment C - Price Proposal Form.docx DOCX document
1686626dwg10of14_GENERAL SERIES.pdf PDF
1686626dwg02of14_LIFESAFETY.pdf PDF
Show 40 more

Latest 50 of 63 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTE: LEGEND IS UNABRIDGED.

SOME SYMBOLOGY & PIPING

LINETYPES INDICATED MAY NOT

BE INCLUDED IN PROJECT.

ACID WASTE

DEIONIZED WATER

DENTAL ORAL EVACUATION

TREATED WATER (REVERSE OSMOSIS)

DOMESTIC COLD WATER

DOMESTIC HOT WATER

DOMESTIC HOT WATER, 140º

DOMESTIC HOT WATER, 160º

DOMESTIC HOT WATER RETURN

TEPID WATER

GREASE WASTE

INSTRUMENT COMPRESSED AIR

LAB COMPRESSED AIR - DENTAL (30-35 PSIG)

LAB COMPRESSED AIR - MEDICAL (50-55 PSIG)

LAB DUST EVACUATION

MEDICAL CARBON DIOXIDE

MEDICAL COMPRESSED AIR

MEDICAL HELIUM

MEDICAL HYDROGEN

MEDICAL NITROGEN

MEDICAL NITROUS OXIDE

MEDICAL OXYGEN

MEDICAL SURGICAL VACUUM

MEDICAL WAGD

NATURAL GAS, 2 PSIG

PROCESS COMPRESSED AIR

SANITARY WASTE

UNDERGROUND PIPE

STORM DRAIN

OVERFLOW DRAIN

ACID

NG

SS

PLUMBING LEGEND (UNABRIDGED)

OD

SD

LA

LA

IA

PA

MA

MV

OE

LDE

WAGD

O

CO2

NO

N

HE

H

DI

TR

140º

160º

TW

GR

FLOOR CLEANOUTFCO

CLEANOUT TO GRADECOTG

WATER METER

(PULSE ACCUMULATOR

OUTPUT TO BAS)

CONNECT TO EXISTING

AT INDICATED POINT

HUB DRAINHD

FLOOR SINKFS-1

FLOOR DRAINFD-1

ROOF DRAINRD

OVERFLOW DRAINOD

RD

OD

ROOF DRAIN ASSEMBLY

(SEE ARCH.)

BUTTERFLY VALVE

GATE VALVE

NON-SLAM CHECK VALVE

PLUG VALVE

CALIBRATED BALANCING VALVE

GAS COCK

WATER HAMMER ARRESTOR

HOSE BIBB

HB

WALL HYDRANT (FREEZE PROOF)

WH

ELBOW, TURNED DOWN

ELBOW, TURNED UP

BRANCH BOTTOM CONNECTION

BRANCH TOP CONNECTION

CAP OR PLUG

PUMP

RISE OR DROP

NON-POTABLE WATERNPW

CLEANOUT CO

A

UNION

CEILING ACCESS PANEL

DENTAL COMPRESSED AIRDA

DENTAL SURGICAL VACUUMDSV

BALL VALVE

UNIT MARK

SEE ABBREVIATIONS

XXX-#

VENT

THERMOMETER

PRESSURE GAUGE

BACKFLOW PREVENTER

(SEE DETAILS FOR TYPE)

ELECTRONIC TRAP PRIMER

FLOOR SINK, FLOOR DRAIN,

HUB DRAIN CONNECTION

IDENTIFIER

DRAIN CONNECTION

IDENTIFIER TO ETP

PIPE SIZE TRANSITION

M

LOW VOLTAGE WIRE

PRESSURE RELIEF VALVE

3 WAY MOTORIZED

CONTROL VALVE

M

DUPLEX AIR FILTER

FLEXIBLE CONNECTOR

PRESSURE REDUCING VALVE

SOFTENED COLD WATER

SOFTENED HOT WATER

SOFTENED HOT WATER RETURN

SOFTENED HOT WATER, 140°S140º

SHWR

SHW

SCW

V

ETP-2-Z

ELECTRONIC TRAP PRIMER

CONNECTION IDENTIFIER

DOMESTIC WATER PLAN EXAMPLE.

ALSO SEE SANITARY PLANS FOR

DRAIN FIXTURE LOCATION.

FD-1

ETP MARK IDENTIFIER

(ETP-1)

ETP-1-#

ETP-2-#

ETP MARK IDENTIFIER

(ETP-2)

REDUCED PRESSURE BACKFLOW

PREVENTER (RPBP)

AIR EXHAUSTAE

AIR INTAKEAI

REDUCED PRESSURE BACKFLOW

PREVENTER (RPBP) WITH STRAINER

ZVB-#

ZVB MARK IDENTIFIER

MEDICAL GAS PIPE FROM ZVB

TO SERVED UNITS (TYP)

MEDICAL GAS PIPE FROM

MEDICAL GAS SOURCE TO

ZVB (TYP)

8" SLAB STEP (DEPRESSED

AREA)

OVERFLOW DRAIN

DOWNSPOUT

OD DS

MONITOR (OUTPUT TO BAS)M

MATCHLINE

NOTE: MATCHLINES APPLY TO

PLUMBING SHEETS ONLY.

Z

MOTOR

STARTER

COMBINATION MOTOR STARTER

WITH INTEGRAL DISCONNECT

DISCONNECT

FUSED DISCONNECT

MOTOR RATED TOGGLE SWITCHM

M

CONTROL CONTACTS

POWER LINE (BY DIV 26)

LOW VOLTAGE WIRE

NOTE: NO PIPING ALLOWED TO BE

EMBEDDED HORIZONTALLY WITHIN THE

THICKNESS OF CONCRETE SLABS AND

CONCRETE FILL ON METAL DECK.

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:0

:5

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

12" = 1'-0"

P-001

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

P L

U M

B

IN

G A

B B

R E

V

IA

T

IO

N S

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909144

WET WET CLE

GCM

NPT NATIONAL PIPE THREAD

NPW NON-POTABLE WATER

NTS NOT TO SCALE

O OXYGEN

OD OVERFLOW DRAIN

OE ORAL EVACUATION

OEE ORAL EVACUATION EXHAUST

PA PROCESS AIR

PB PRESSURE BOOSTER

PD PRESSURE DROP

PDI PLUMBING DRAINAGE INSTITUTE

PH PHASE

PLBG PLUMBING

PRESS. PRESSURE

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIG POUNDS PER SQUARE INCH GAUGE

PT PLASTER TRAP

PV PLUG VALVE

PWB PLUMBING WALL BOX

RCT RECEIVER TANK

RD ROOF DRAIN

REF REFERENCE

REG REGULATING

RENO RENOVATE / RENOVATION

REQD REQUIRED

RM ROOM

RO REVERSE OSMOSIS

RP RECIRCULATION PUMP

RPBP REDUCED PRESSURE BACKFLOW PREVENTER

RPM ROTATIONS PER MINUTE

RW RAINWATER

S SINK

SAN SANITARY

SCW SOFT COLD WATER

SD STORM DRAIN

SDR STANDARD DIMENSION RATIO

SDU SUPPLY AND DRAIN UNIT

SE SEWAGE EJECTOR

SEP SEPARATOR TANK

SFU SUPPLY FIXTURE UNITS

SH SHOWER

SHT SHEET

SHW SOFT HOT WATER

SHWR SOFT HOT WATER RETURN

SIM SIMILAR

SP SUMP PUMP

SPEC SPECIFICATION

SQ SQUARE

SRW SECONDARY RAINWATER

SS SANITARY SEWER; STAINLESS STEEL

ST SEPARATOR TANK

STRUC STRUCTURAL

SYS SYSTEM

T&P TEMPERATURE AND PRESSURE

TEMP TEMPERATURE; TEMPORARY

TMV THERMOSTATIC MIXING VALVE

TLT TOILET

TP TRAP PRIMER

TR TREATED WATER

TS TEMPERATURE SENSOR

TW TEPID WATER

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

UR URINAL

V VENT, VOLTS

VP VACUUM PUMP

VTR VENT THRU ROOF

W WASTE

W/ WITH

WAGD WASTE ANESTHETIZING GAS DISPOSAL

WAGE WASTE ANESTHETIZING GAS EXHAUST

WC WATER CLOSET; WATER COLUMN

WCO WALL CLEANOUT

WH WALL HYDRANT

WHA WATER HAMMER ARRESTOR

WM WATER METER

WS WATER SOFTENER, WASTE STACK

WST WATER SOFTENER TANK

ZVB MEDICAL GAS ZONE VALVE BOX

ELEV ELEVATOR

EMV EMERGENCY MIXING VALVE

EQMT EQUIPMENT

ESEW EMERGENCY SHOWER / EYEWASH

ES-TMV EMERGENCY SHOWER THERMOSTATIC MIXING VALVE

(PROVIDED WITH FIXTURE)

ET EXPANSION TANK

ETP ELECTRONIC TRAP PRIMER

EW EYEWASH

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EX EXISTING

FA FROM ABOVE

FB FROM BELOW

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FFE FINISHED FLOOR ELEVATION

FIN FLR FINISHED FLOOR

FLR FLOOR

FM FORCE MAIN

FS FLOOR SINK

FT FEET

FW FILTERED WATER

G GAS

GAL GALLON

GPG GRAINS PER GALLON

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GR GREASE WASTE

GTV GATE VALVE

GV GLOBE VALVE

GWH GAS WATER HEATER

HB HOSE BIBB

HBT HYDROPNEUMATIC BUFFER TANK

HC HANDICAP

HD HUB DRAIN

HDPE HIGH DENSITY POLYETHYLENE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HST HOT WATER STORAGE TANK

HVAC HEATING / VENTILATING / AIR CONDITIONING

HWCP HOT WATER CIRCULATING PUMP

Hz HERTZ

IAW IN ACCORDANCE WITH

IE INVERT ELEVATION

IN INCHES

IN. WC INCHES OF WATER, GAUGE

INV INVERT

IPC INTERNATIONAL PLUMBING CODE

JS JANITORS SINK

JSN JOINT SCHEDULE NUMBER

KTR CONTRACTOR

L LAVATORY

LA LAB AIR - DENTAL / MEDICAL

LAI LAB AIR INTAKE

LAP LOCAL ALARM PANEL

LAV LAVATORY

LDPE LOW DENSITY POLYETHYLENE

LF LINEAR FEET

LP LIQUIFIED PETROLEUM GAS

LVL LEVEL

MA MEDICAL COMPRESSED AIR

MAC MEDICAL AIR COMPRESSOR

MAI MEDICAL AIR INTAKE

MAP MEDICAL GAS MASTER ALARM PANEL

MAX MAXIMUM

MECH MECHANICAL

MED MEDICAL

MFR MANUFACTURER

MG MEDICAL GAS

MIN MINIMUM

MS MOP SINK

MTD MOUNTED

MV MEDICAL SURGICAL VACUUM

MVE MEDICAL VACUUM EXHAUST

MX MIXING VALVE

N NITROGEN

NC NORMALLY CLOSED

NCC NITROGEN CONTROL CABINET

NG NATURAL GAS

NO NITROUS OXIDE

AAP MEDICAL GAS AREA ALARM PANEL

ABBRV ABBREVIATION

ABV ABOVE

AC ABOVE CEILING; AIR COMPRESSOR

AD AREA DRAIN

ADD'L ADDITIONAL

AE AIR EXHAUST

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHU AIR HANDLING UNIT

AI AIR INTAKE; ANALOG INPUT

ALT ALTERNATE

AO ANALOG OUTPUT

APR AIR PRESSURE REDUCING STATION

ARCH ARCHITECTURAL

AS AMALGAM SEPARATOR

ASSY ASSEMBLY

AUTO AUTOMATIC

BAS BASE AUTOMATION SYSTEM

BCW BOOSTED COLD WATER

BF BELOW FLOOR

BFF BELOW FINISHED FLOOR

BFG BELOW FINISHED GRADE

BFP BACKFLOW PREVENTER

BHW BOOSTED HOT WATER

BI BINARY INPUT

BLDG BUILDING

BLK BLOCK

BLV BALANCING VALVE

BO BINARY OUTPUT

BSMT BASEMENT

BT BRINE TANK

BTUH BRITISH THERMAL UNITS PER HOUR

BV BALL VALVE

BWV BACKWATER VALVE

CA COMPRESSED AIR

CAI COMPRESSED AIR INTAKE

CAP CAPACITY

CD CONDENSATE WASTE

CF CUBIC FEET

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CLEANOUT; CARBON MONOXIDE

CO2 CARBON DIOXIDE

COMM COMMUNICATIONS

COMP. COMPOSITE

CONC CONCRETE

COND CONDENSATE

CONN CONNECTION

CONT CONTINUATION; CONTINUOUS

COR CONTRACTING OFFICER'S REPRESENTATIVE

COTG CLEANOUT TO GRADE

CU CUBIC; COPPER

CV CHECK VALVE

CVTR CONCENTRIC VENT KIT THRU ROOF

DA DENTAL COMPRESSED AIR

DAC DENTAL AIR COMPRESSOR

DAI DENTAL AIR INTAKE

DCW DOMESTIC COLD WATER

DDC DIRECT DIGITAL CONTROLS

DEMO DEMOLISH / DEMOLITION

DFU DRAIN FIXTURE UNITS

DHW DOMESTIC HOT WATER

DHWR DOMESTIC HOT WATER RETURN

DI DEIONIZED WATER

DIA DIAMETER

DN DOWN

DOR DESIGNER OF RECORD

DS DOWNSPOUT

DSV DENTAL SURGICAL VACUUM

DSVE DENTAL SURGICAL VACUUM EXHAUST

DWBP DOMESTIC WATER BOOSTER PUMP

DWG DRAWING

DWH DOMESTIC WATER HEATER

EA EACH

EE-TMV EMERGENCY EYEWASH THERMOSTATIC MIXING

VALVE (PROVIDED WITH FIXTURE)

EL ELEVATION

ELEC ELECTRICAL

PLUMBING ABBREVIATIONS (UNABRIDGED)

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L L

I AM

A

B B.9 C C.9 D D.6 E E.4 E.6 F G H H.4 H.6 J J.4 K K.1 L M N

6.2

5.6

4.8

2.2

FCO FCO

FCO FCO

FCO

FCO

FCO FCO

FCO

491 DFU

MATCHLINE: 1G

MATCHLINE: 1A

M A

T C

H

LI

N E

: 1 A

M A

T C

H

LI

N E

: 1 M

MATCHLINE: 1B

MATCHLINE: 1M

MATCHLINE: 1C

MATCHLINE: 1M

MATCHLINE: 1D

MATCHLINE: 1M

M A

T C

H

LI

N E

: 1 M

M A

T C

H

LI

N E

: 1 F

M A

T C

H

LI

N E

: 1 G

M A

T C

H

LI

N E

: 1 H

M A

T C

H

LI

N E

: 1 H

M A

T C

H

LI

N E

: 1 J

M A

T C

H

LI

N E

: 1 J

M A

T C

H

LI

N E

: 1 K

M A

T C

H

LI

N E

: 1 K

M A

T C

H

LI

N E

: 1 L

MATCHLINE: 1K

MATCHLINE: 1F

MATCHLINE: 1A

MATCHLINE: MECH YARD

DFU

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

6' 12' 24'

SCALE: 3/32"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:0

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

3/32" = 1'-0"

SCALE: 3/32" = 1'-0"

PW011

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

C

O M

P O

S

IT

E

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909145

WET WET CLE

BELOW SLAB WASTE PLAN -

COMPOSITE

GCM

SHEET NOTES:

1. ALL SANITARY AND VENT PIPING SHOWN ON PW011-PW022 IS LOCATED BELOW SLAB.

2. SEE PW111-PW122 FOR PIPING LOCATION ABOVE FINISHED FLOOR AND UP TO THE UNDERSIDE OF THE SECOND FLOOR SLAB.

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

A B C D

DTR-GEN

1H14

MECH

1A01

MAIN ELEC

1A01B

MAIN ELEC

1A01A

WC-2

WC-2

WC-1

FS-4

FS-4

FCO

TMV-1

436 DFU

FS-4

COORDINATE 6" SS PIPE

WITH UNDERGROUND

ELECTRICAL SERVICES

6" SS

FD-3

WCO FCO

MATCHLINE: 1G

MATCHLINE: 1A

M A

T C

H

LI

N E

: 1 A

M A

T C

H

LI

N E

: 1 M

MATCHLINE: 1B

MATCHLINE: 1M

MATCHLINE: 1A

MATCHLINE: MECH YARD

SEE CU102 FOR

CONTINUATION

6" SS 6" SS

4" SS 4" SS

6" S

D0680

4" SS

2" SS

4" SS

FCO

4"

4"

S

4" SS

FS-4

4"

FS-4

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

4"

WCO

COTG

4"

4"

5' IE

SS PASSES UNDER FOOTER AT

THIS LOCATION. SEE CIVIL FOR

ROUTING DETAILS AND SOIL

PREP. CU502

M A

T C

H

LI

N E

: 1 G

M A

T C

H

LI

N E

: 1 H

A A

A

A

A

A

FS-4

B

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:1

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW012

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909146

WET WET CLE

BELOW SLAB WASTE PLAN - BLOCK 0A

GCM

SHEET NOTES:

4" SS FROM FIRST FLOOR

4" SS FROM FIRST FLOOR

2" V UP TO FIRST FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

D E F

RECRUIT

WAITING

1B02a

LOBBY

1B02

VESTIBULE

1B01

RECRUIT PUB

TLT, F

1B03

RECRUIT PUB

TLT, M

1B04

RECRUIT PUB

TLT, M

1B05

RECRUIT PUB

TLT, F

1B07

L-4 L-4

WC-2

WC-2

WC-1

L-4 L-4

JC-1

EW-1

FS-4

4"

FCO

WC-2

WC-2

WC-1

BF-2 BF-2BF-2 BF-2

U-1 U-2 U-2

6" SS

FD-3 FD-3

FD-3FD-3

4" SS

WCO

FCO

WCO FCO

WCO

M A

T C

H

LI

N E

: 1 A

M A

T C

H

LI

N E

: 1 M

MATCHLINE: 1C

MATCHLINE: 1M

MATCHLINE: 1B

MATCHLINE: 1M

3"

3" SS

D0680

D0680

4" SS

2" SS

2" SS

4" SS

1 1

WC-2

WC-2

WC-2

U-2

WC-2

WC-2

U-2

L-3 L-3

L-3 L-3

4"

1 1

1 13

FS-4

6" SS

D0680 D0680 D0680

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

WCO

WC-2

MATCHLINE: 1G

MATCHLINE: 1A

MATCHLINE: 1H

MATCHLINE: 1B

A

A

B B

C C

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:1

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW013

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

B

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909147

WET WET CLE

BELOW SLAB WASTE PLAN - BLOCK 0B

GCM

SHEET NOTES:

2" V UP TO FIRST FLOOR

3" V UP TO FIRST FLOOR

3" SS FROM FIRST FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

F G H

2.2

CBCT

1J13

PANO-CEPH

1C05

PANO-CEPH

1C04

PANO-CEPH

1C06

CLASSROOM

1C01

RECORDS

1C03B

CONSULT OFC

1C03D

RECEP

1C03A

COPY

1C03h

L-2

JC-1

EW-1

CORRIDOR

1CC2

6" SS

EWC-1

L-2 L-2

6" SS

SEP-1

FD-3

MATCHLINE: 1C

MATCHLINE: 1M

MATCHLINE: 1D

MATCHLINE: 1M

RECRUIT

IP/CLIN SPT

1C01A

ELEV MACH

1C02

2"

L-2MATCHLINE: 1J

MATCHLINE: 1C

MATCHLINE: 1K

MATCHLINE: 1D

3"

2" SS

2"

6" SS

2"

SP-1

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

BELOW SLAB FORCE MAIN FROM SP-1

2" FM

F M

CONNECT 2" FM INTO TOP OF 6" SS

MAIN WITH WYE FITTING

AS-1A

3" SS

MATCHLINE: 1H

MATCHLINE: 1B

MATCHLINE: 1B

MATCHLINE: 1M

C

CORRIDOR

1JC3

LOBBY

1C07

SP-1 CONTROL PANEL

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:2

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW014

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

C

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909148

WET WET CLE

BELOW SLAB WASTE PLAN - BLOCK 0C

GCM

SHEET NOTES:

2" V UP TO FIRST FLOOR

3" SS FROM FIRST FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

H J K

RAD OFC

1D13

GAS STOR

1D18

EQ STOR

1D16

SOIL UTIL

1D15

MED WASTE

1D17

DEPT HEAD

GEN

DENTISTRY

1D11

AD WAITING

1D03c

LOBBY

SEATING

1D03a

EQ STOR

1D06

VESTIBULE

1D01

AD TLT

1D05

COMM RM

1D08

JAN CL

1D07

L-2

SS-1

S-4

WC-1

L-1

JC-1

EW-1

FCO

FS-4

FCO

RECORD

ASSEMBLY /

WORK

1D02

CREDENTIALING

DENTISTS

1D14

4" SS UP

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

4"

4" SS 6" SS

3"

4" SS 4" SS

MATCHLINE: 1D

MATCHLINE: 1M

M A

T C

H

LI

N E

: 1 M

M A

T C

H

LI

N E

: 1 F

DEPT HEAD

GEN/ASSIST

1D10

4" SS

2"

MECH

1F04

MATCHLINE: 1K

MATCHLINE: 1D

2" SS

4" SS 4" SS 4" SS 4" SS

6" SS

FCO

4" SS

4"

M

T C

H

LI

N E

: 1 C

MATCHLINE: 1J

MATCHLINE: 1C

MATCHLINE: 1L

MATCHLINE: 1F

D

EW-1

EMV-2

EMV-2

EW-1

1 1

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:2

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW015

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909149

WET WET CLE

BELOW SLAB WASTE PLAN - BLOCK 0D

GCM

SHEET NOTES:

2" V UP TO FIRST FLOOR

3" V UP TO FIRST FLOOR

4" SS FROM FIRST FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

K L M N

GAS STOR

1D18

CHEM STOR

1F03a

ELEV MACH

1F02

SUPPLY STOR

1F03

ELEC

1F01

ES-1

FS-4

FS-4

FCO

CORRIDOR

1FC2

STAIR

1FS2

EWC-1

4"

A

T C

H

LI

N E

: 1 M

M A

T C

H

LI

N E

: 1 F

MATCHLINE: 1L

MATCHLINE: 1F

MECH

1F04

4" SS

2"

FCO

2" SS

4" SS 4" SS 4" SS

4"

SP-2

CONNECT 2" FM INTO TOP OF

4" SS MAIN WITH WYE FITTING.

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

BELOW SLAB FORCE MAIN FROM SP-2

FM

MATCHLINE: 1K

MATCHLINE: 1D

D

D

SP-2 CONTROL PANEL

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:3

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW016

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

F

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909150

WET WET CLE

BELOW SLAB WASTE PLAN - BLOCK 0F

GCM

SHEET NOTES:

2" V UP TO FIRST FLOOR

4" SS FROM FIRST FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

ST TLT

1G11

FCO

DIR DENTAL

SVCS

1G03

OPS OFFICER

1G02

CORRIDOR

1GC2

SEL OFC

1G04

TEAM COLLAB

1G05

CLINIC MGR

1G01

CORRIDOR

1GC1

STAIR

1GS1

LPCO CLINIC

1G07

MANAGED

CARE

1G06

CORRIDOR

1GC3

LACT RM

1G10

CORRIDOR

1GC4

WC-1

L-1

S-1

D0680

D0680

FD-3

MATCHLINE: 1G

MATCHLINE: 1A

M A

T C

H

LI

N E

: 1 G

M A

T C

H

LI

N E

: 1 H

4" SS 4" SS

2"

SEE CU102 FOR

CONTINUATION

6"

4" SS

2"

3" SS

2" SS

4" SS

4"

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

134" S

S

WCO

4'- 6" IE

COTG

110 DFU

A

A

B

4" SS

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:3

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW017

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

G

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909151

WET WET CLE

BELOW SLAB WASTE PLAN - BLOCK 0G

GCM

SHEET NOTES:

2" SS FROM FIRST FLOOR

3" SS FROM FIRST FLOOR

2" V UP TO FIRST FLOOR

4" V UP TO FIRST FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

4.8

DTR-GEN

1H01

DTR-GEN

1H03

DTR-GEN

1H08

DTR-GEN

1H10

DTR-GEN

1H09

DTR-GEN

1H15

DTR-GEN

1H19

DTR-GEN

1H21

DTR-GEN

1H14

DTR-GEN

1H06

DTR-GEN

1H02

DTR-GEN

1H16

DTR-GEN

1H18

DTR-GEN

1H20

DTR-GEN

1H22

PT TLT

1H25

PT TLT

1H12

RECRUIT PUB

TLT, F

1B03

RECRUIT PUB

TLT, M

1B04

COMM RM

1H13

JAN CL

1H24

ELEC

1H23

CAD/CAM

MILLING

1J01

CORRIDOR

1HC2

L-4 L-4

WC-2

WC-2

L-4 L-4

WC-1

L-1

WC-1

WC-1

JC-1

EW-1

EW-1

D0680

D0680 D0680

D0680

D0680 D0680 D0680

D0680 D0680

ST TLT

1H11

CORRIDOR

1HC1

U-1 U-2 U-2

4" SS

L-1

2" SS

FD-3FD-3

4" SS

FCO

M A

T C

H

LI

N E

: 1 G

M A

T C

H

LI

N E

: 1 H

DTR-GEN

1H04

DTR-GEN

1H05

DTR - GEN

1H07

D0680 D0680

L-1

D0680

D0680

4" SS

3"

D0680

D0680

4" SS

MATCHLINE: 1J

MATCHLINE: 1C

4" SS

4" SS 4" SS 4" SS 4" SS

2"

2" SS 2" SS 2" SS 2" SS 3" SS

2" SS

2" SS

2" SS

2" SS

2" SS 2" SS

2" SS

4"

2" SS 2" SS

2" SS

2" SS

3 3 3

3 3 3

3 3

4" SS

D0680 D0680 D0680

WCO

DO NOT ROUTE PLUMBING

PIPING THROUGH ELEVATOR

SHAFTS, STAIRWELLS, DATA,

AND ELECTRICAL ROOMS. (TYP.)

FCO

FCO

MATCHLINE: 1G

MATCHLINE: 1A

MATCHLINE: 1H

MATCHLINE: 1B

B

SS PASSES

THROUGH SLEEVE

EMBEDDED IN

FOUNDATION. SEE

D1/S-505SS PASSES THROUGH

SLEEVE EMBEDDED IN

FOUNDATION. SEE C1/S-505

SS PASSES THROUGH

SLEEVE EMBEDDED IN

FOUNDATION. SEE D1/S-505

SS PASSES THROUGH

SLEEVE EMBEDDED IN

FOUNDATION. SEE C1/S-505

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:4

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW018

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

H

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909152

WET WET CLE

BELOW SLAB WASTE PLAN - BLOCK 0H

GCM

SHEET NOTES:

4" SS FROM FIRST FLOOR

2" SS FROM FIRST FLOOR

2" V UP TO FIRST FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

DTR-GEN

1J12

DTR-GEN

1J10

DTR-GEN

1J07

DTR-GEN

1J03

CBCT

1J13

PANO-CEPH

1C04

PANO-CEPH

1C06

DTR-GEN

1J08

DTR-GEN

1J04

PT TLT

1H12

MAIN COMM RM

1J02

DTR-GEN

1J06

CAD/CAM

MILLING

1J01

CAD/CAM

MILLING

1J11

L-2

WC-1

L-1

WC-1

WC-1

JC-1

S-5

EW-1

S-3 S-3

S-5

EW-1

JC-1

WC-1

L-1

EMV-2

EMV-2

EW-1

FCO

FCO

L-2 L-2

4" SS

L-1

2" SS 2" SS

2"

OE-2

OE-1 DSV-1

DAC-1

SEP-3

SEP-4

SEP-2

SEP-1

2"

T C

H

LI

N E

: 1 H

M A

T C

H

LI

N E

: 1 J

M A

T C

H

LI

N E

: 1 J

M A

T C

H

LI

N E

: 1 K

DTR-GEN

1J09

DTR-GEN

1J05

DNTG1

D0680D0680 D0680D0680

EMV-2

D0680

4" SS

2"

L-2MATCHLINE: 1J

MATCHLINE: 1K

MATCHLINE: 1D

4" SS

4" SS

4"

4" SS 4" SS 4" SS

2" SS

2" SS

2 3

FS-4

FS-4

FS-4

FS-4

AS-1A

A S

-2 A

DO NOT ROUTE

PLUMBING PIPING

THROUGH ELEVATOR

SHAFTS, STAIRWELLS,

DATA, AND ELECTRICAL

ROOMS. (TYP.)

FCO

FCO

3" SS

4" SS 4"

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND ELECTRICAL

ROOMS. (TYP.)

MATCHLINE: 1H

MATCHLINE: 1B

MATCHLINE: 1J

MATCHLINE: 1C

E E

E

E

SS PASSES

THROUGH SLEEVE

EMBEDDED IN

FOUNDATION. SEE

D1/S-505

CORRIDOR

1JC3

4"

3"

2"

D0680

D0680

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:5

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW019

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

J

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909153

WET WET CLE

BELOW SLAB WASTE PLAN - BLOCK 0J

GCM

SHEET NOTES:

2" SS FROM SECOND FLOOR

3" SS FROM SECOND FLOOR

2" V UP TO FIRST FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

DTR-GEN

1K18

DTR-GEN

1K19

DTR-GEN

1K09

DTR-GEN

1K11

DTR-GEN

1K05

DTR-GEN

1K16

PT TLT

1K01

PT TLT

1K20

DTR-GEN

1K04

RAD OFC

1D13

GAS STOR

1D18

EQ STOR

1D16

SOIL UTIL

1D15

MED WASTE

1D17

DTR-GEN

1K10

DTR-GEN

1K12

DTR-GEN

1K06

DTR-GEN

1K08DTR-GEN

1J08

DTR-GEN

1K03

JAN CL

1K02

ELEC

1K15

CAD/CAM

MILLING

1J11

SS-1

S-5

EW-1

JC-1

WC-1

L-1

WC-1

D0680

EMV-2

D0680

FCO

4" SS

FCO

L-2

2" SS

2"

M A

T C

H

LI

N E

: 1 J

M A

T C

H

LI

N E

: 1 K

M A

T C

H

LI

N E

: 1 K

M A

T C

H

LI

N E

: 1 L

DTR-GEN

1J09

DTR-GEN

1K07

DTR-GEN

1K17

EMV-2

4" SS

4"

L-2

3" S

S

2" SS

2" SS 2" SS

2" SS 4" SS

2" SS

2" SS

2" SS 2" SS

2" SS

2" SS

4" SS 4" SS 4" SS 4" SS

3 3 3

2 3

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND ELECTRICAL

ROOMS. (TYP.)

MATCHLINE: 1J

MATCHLINE: 1C

MATCHLINE: 1L

MATCHLINE: 1F

MATCHLINE: 1K

MATCHLINE: 1D

EW-1

EMV-2

EMV-2

EW-1

4"

D0680 D0680

D0680 D0680 D0680 D0680

4" SS

2" SS

D0680 D0680 D0680 D0680

2" SS

1 1

PM120

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:0

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW020

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

K

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909154

WET WET CLE

BELOW SLAB WASTE PLAN - BLOCK 0K

GCM

SHEET NOTES:

2" SS FROM SECOND FLOOR

4" SS FROM SECOND FLOOR

2" V UP TO FIRST FLOOR

3" V UP TO FIRST FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

PT TLT

1K20

2ND DET

DENTISTS

1L05b

2ND DET

DENTISTS

1L05c

ENTERPRISE

1L05a

SMALL TEAMS

1L05

LCPO 2ND DET

1L03

LPO AND

SUPER GEN

DEN

1L02

ST TLT

1L04

DTR-GEN

1K12

WC-1

L-1

WC-1

D0680

D0680

4" SS

FCO STAIR

1FS2

4"

A

T C

H

LI

N E

: 1 K

M A

T C

H

LI

N E

: 1 L

MATCHLINE: 1L

MATCHLINE: 1F

OIC 2ND DET

1L01

4"

2" SS

4" SS 4" SS

WCO

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND ELECTRICAL

ROOMS. (TYP.)

MATCHLINE: 1K

MATCHLINE: 1D

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:0

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW021

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

L

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909155

WET WET CLE

BELOW SLAB WASTE PLAN - BLOCK 0L

GCM

SHEET NOTES:

2" SS FROM SECOND FLOOR

4" SS FROM SECOND FLOOR

2" V UP TO FIRST FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

D.6 E E.4 E.6 F G

2.2

STAGING AREA

1M01a

WCO

MATCHLINE: 1C

MATCHLINE: 1M

MATCHLINE: 1B

MATCHLINE: 1M

G H H.4 H.6 J J.4

2.2

STAGING AREA

1M01a

MATCHLINE: 1D

MATCHLINE: 1M

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:1

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

PW022

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

M

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909156

WET WET CLE

GCM

SCALE: 1/4" = 1'-0"

PARTIAL BELOW SLAB WASTE PLAN - BLOCK 0M-A

C1

SCALE: 1/4" = 1'-0"

PARTIAL BELOW SLAB WASTE PLAN - BLOCK 0M-B

A2

A B

SHEET NOTES:

1. NO SANITARY WORK ON THIS SHEET. ONLY SHOWN FOR CLARITY.

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

B C D

M A

T C

H

LI

N E

: M E

C H

Y A

R D

M A

T C

H

LI

N E

: 1 M

MATCHLINE: 1A

MATCHLINE: MECH YARD

6" SS

FD-6

2" V UP

AREA DRAIN FOR CHILLERS.

PROVIDE WITH REMOVABLE

COVER TO ONLY DRAIN

WHEN NEEDED.

SEE CU103 FOR

CONTINUATION

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

4' 8' 16'

SCALE: 1/8"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:1

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/8" = 1'-0"

PW023

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

B E

L O

W S

L A

B W

A S

T E

P L

A N

B

L O

C K

M E

C H

Y A

R D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909157

WET WET CLE

BELOW SLAB WASTE PLAN - BLOCK

MECH YARD

GCM

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

6.2

5.6

4.8

2.2

DTR-GEN

1J12

DTR-GEN

1K18

DTR-GEN

1K19

DTR-GEN

1J10

DTR-GEN

1K09

DTR-GEN

1H01

DTR-GEN

1H03

DTR-GEN

1K11

DTR-GEN

1H08

DTR-GEN

1H10

DTR-GEN

1H09

DTR-GEN

1H15

DTR-GEN

1H19

DTR-GEN

1H21

DTR-GEN

1H14

DTR-GEN

1K05

DTR-GEN

1J07

DTR-GEN

1H06

DTR - GEN

1H07

DTR-GEN

1J03

DTR-GEN

1K16

PT TLT

1K01

PT TLT

1K20

DTR-GEN

1K04

CBCT

1J13

PANO-CEPH

1C05

PANO-CEPH

1C04

PANO-CEPH

1C06

RAD OFC

1D13

CUB SPLY

1F03b

CC ALC

1JC1a

GAS STOR

1D18

CHEM STOR

1F03a

EQ STOR

1D16

BOTTLE FILL

1JC1c

SOIL UTIL

1D15 MED WASTE

1D17

2ND DET

DENTISTS

1L05b

2ND DET

DENTISTS

1L05c

ENTERPRISE

1L05a

SMALL TEAMS

1L05

LCPO 2ND DET

1L03

DEPT HEAD

GEN

DENTISTRY

1D11

LPO AND

SUPER GEN

DEN

1L02

ST TLT

1L04

CLASSROOM

1C01

RECORDS

1C03B

CONSULT OFC

1C03D

RECEP

1C03A

COPY

1C03h

AD WAITING

1D03c

RECRUIT

WAITING

1B02a

DTR-GEN

1K10 DTR-GEN

1K12

DTR-GEN

1K06

DTR-GEN

1K08

DTR-GEN

1J08DTR-GEN

1J04

DTR-GEN

1H02

DTR-GEN

1H16

DTR-GEN

1H18 DTR-GEN

1H20

DTR-GEN

1H22

PT TLT

1H25

PT TLT

1H12

DTR-GEN

1K03

LOBBY

1B02

LOBBY

SEATING

1D03a

EQ STOR

1D06

VESTIBULE

1B01

VESTIBULE

1D01

ST TLT

1G11

AD TLT

1D05

RECRUIT PUB

TLT, F

1B03 RECRUIT PUB

TLT, M

1B04

COMM RM

1D08

COMM RM

1H13

MAIN COMM RM

1J02

JAN CL

1H24

JAN CL

1K02

JAN CL

1D07

MECH

1A01

ELEC

1H23

ELEC

1K15

MAIN ELEC

1A01B

DTR-GEN

1J06

CAD/CAM ALC

1JC1d

ELEV MACH

1F02

REC DIST/SIGN

1C03f

REC DIST/SIGN

1C03g

AD KIOSK

1D03b

STAGING AREA

1M01a

SUPPLY STOR

1F03

RECYCLE

1F05

CAD/CAM

MILLING

1J01

CAD/CAM

MILLING

1J11

ELEC

1F01

MAIN ELEC

1A01A

RECRUIT

WAITING

1B02b

MATCHLINE: 1G

MATCHLINE: 1A

M A

T C

H

LI

N E

: 1 A

M A

T C

H

LI

N E

: 1 M

MATCHLINE: 1B

MATCHLINE: 1M

MATCHLINE: 1C

MATCHLINE: 1M

MATCHLINE: 1D

MATCHLINE: 1M

M A

T C

H

LI

N E

: 1 M

M A

T C

H

LI

N E

: 1 F

M A

T C

H

LI

N E

: 1 G

M A

T C

H

LI

N E

: 1 H

M A

T C

H

LI

N E

: 1 H

M A

T C

H

LI

N E

: 1 J

M A

T C

H

LI

N E

: 1 J

M A

T C

H

LI

N E

: 1 K

M A

T C

H

LI

N E

: 1 K

M A

T C

H

LI

N E

: 1 L

MATCHLINE: 1K

MATCHLINE: 1F

MATCHLINE: 1A

MATCHLINE: MECH YARD

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

6' 12' 24'

SCALE: 3/32"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:3

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

3/32" = 1'-0"

SCALE: 3/32" = 1'-0"

PW111

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

F

IR

S T

F L

O O

R W

A S

T E

P L

A N

C

O M

P O

S

IT

E

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909158

WET WET CLE

FIRST FLOOR WASTE PLAN -

COMPOSITE

GCM

SHEET NOTES:

1. ALL SANITARY AND VENT PIPING SHOWN ON PW111-122 IS LOCATED ABOVE THE FINISHED FLOOR AND UP TO THE UNDERSIDE OF THE SECOND FLOOR SLAB.

2. SEE PW011-022 FOR PIPING AT FIRST FLOOR LEVEL AND BELOW.

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

MECH

1A01

MAIN ELEC

1A01B

MAIN ELEC

1A01A

STAIR

1GS1 WC-2

WC-2

WC-1

FS-4

FS-4

DTR-GEN

1H14

FCO

FS-4

2" SS

MATCHLINE: 1G

MATCHLINE: 1A

M A

T C

H

LI

N E

: 1 A

M A

T C

H

LI

N E

: 1 M

MATCHLINE: 1B

MATCHLINE: 1M

WCO

2" V

MATCHLINE: 1A

MATCHLINE: MECH YARD

2 2

23 3 3 3 3

4" SS 4" SS 4" SS

3"

4" SS 4" SS

FS-41 4" SS

4" SS

FS-4

2"

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

2" V UP

2" V UP

2" V

FD-3

V

3" SS

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

M A

T C

H

LI

N E

: 1 G

M A

T C

H

LI

N E

: 1 H

A A

A

A A

A

B

FCO

FS-4

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:3

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW112

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

F

IR

S T

F L

O O

R W

A S

T E

P L

A N

B

L O

C K

A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909159

WET WET CLE

FIRST FLOOR WASTE PLAN - BLOCK 1A

GCM

SHEET NOTES:

4" SS DOWN TO BELOW SLAB

2" SS FROM SECOND FLOOR

3" SS FROM SECOND FLOOR

4" SS FROM SECOND FLOOR

3" SS DOWN TO BELOW SLAB

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

RECRUIT PUB

TLT, F

1B03

RECRUIT PUB

TLT, M

1B04

CORRIDOR

1BC1

LOBBY

1B02

VESTIBULE

1B01

RECRUIT PUB

TLT, M

1B05

RECRUIT PUB

TLT, F

1B07

L-4 L-4

WC-2

WC-2

WC-1

L-4 L-4

JC-1

FCO

U-1 U-2 U-2

WC-2 WC-2

WC-1

FCO

M A

T C

H

LI

N E

: 1 A

M A

T C

H

LI

N E

: 1 M

MATCHLINE: 1B

MATCHLINE: 1M

MATCHLINE: 1C

MATCHLINE: 1M

WCO

WCO

2" V 2" V

3"

2" V

3" SS

M A

T C

H

LI

N E

: 1 B

M A

T C

H

LI

N E

: 1 C

4" SS

3"

WC-2

WC-2

U-2

U-2

L-3

L-3 L-3

L-3

WC-2

WC-2

WC-2

WC-2

FD-3

FD-3

FD-3 2

4" SS

2" V

2" V

2" S

S

3" SS

2" V UP

FCO

FD-3

WCO

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

M A

T C

H

LI

N E

: 1 G

M A

T C

H

LI

N E

: 1 H

A

B B

C C

BF-2 BF-2 BF-2 BF-2

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:4

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW113

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

F

IR

S T

F L

O O

R W

A S

T E

P L

A N

B

L O

C K

B

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909160

WET WET CLE

FIRST FLOOR WASTE PLAN - BLOCK 1B

GCM

SHEET NOTES:

3" V UP TO VTR

2" SS FROM SECOND FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

CORRIDOR

1CC1

PANO-CEPH

1C04

PANO-CEPH

1C05

PANO-CEPH

1C06

RECEP

1C03A

CONSULT OFC

1C03D

CORRIDOR

1CC2

LOBBY

1C07

CLASSROOM

1C01

L-2

JC-1

L-2

JAN CL

1H24

EWC-1

L-2 L-2

SEP-1

2" SS

2" V

MATCHLINE: 1M

MATCHLINE: 1D

MATCHLINE: 1M

RECRUIT

IP/CLIN SPT

1C01A

ELEV MACH

1C02ELEVATOR 2

1CE2

MATCHLINE: 1J

MATCHLINE: 1C

MATCHLINE: 1K

MATCHLINE: 1D

M A

T C

H

LI

N E

: 1 B

M A

T C

H

LI

N E

: 1 C

M A

T C

H

LI

N E

: 1 B

M A

T C

H

LI

N E

: 1 C

3" SS

3"

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

M A

T C

H

LI

N E

: 1 H

C

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:4

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW114

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

F

IR

S T

F L

O O

R W

A S

T E

P L

A N

B

L O

C K

C

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909161

WET WET CLE

FIRST FLOOR WASTE PLAN - BLOCK

1C

GCM

SHEET NOTES:

2" SS FROM SECOND FLOOR

3" SS FROM SECOND FLOOR

2" V UP TO SECOND FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

RAD OFC

1D13

DEPT HEAD

GEN

DENTISTRY

1D11

DEPT HEAD

GEN/ASSIST

1D10

CREDENTIALING

DENTISTS

1D14

SOIL UTIL

1D15

EQ STOR

1D16

MED WASTE

1D17

GAS STOR

1D18

COMM RM

1D08

JAN CL

1D07

CORRIDOR

1DC1

EQ STOR

1D06

AD TLT

1D05

LOBBY

1D03

VESTIBULE

1D01RECORD

ASSEMBLY /

WORK

1D02

L-2

EW-1 EW-1

SS-1

WC-1

L-1

JC-1

EW-1

S-4

FS-4

CORRIDOR

1KC2

FCO

FCO

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

MATCHLINE: 1D

MATCHLINE: 1M M

A

T C

H

LI

N E

: 1 M

M A

T C

H

LI

N E

: 1 F

2" S

S

4"

MATCHLINE: 1K

MATCHLINE: 1D

MATCHLINE: 1L

MATCHLINE: 1F

4" SS

4"

4"

2 2

4"

2"

MATCHLINE: 1J

MATCHLINE: 1C

D

4"

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:5

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW115

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

F

IR

S T

F L

O O

R W

A S

T E

P L

A N

B

L O

C K

D

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909162

WET WET CLE

FIRST FLOOR WASTE PLAN - BLOCK

1D

GCM

SHEET NOTES:

2" SS FROM SECOND FLOOR

4" SS FROM SECOND FLOOR

2" V UP TO SECOND FLOOR

3" V UP TO SECOND FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

COMM RM

1D08

CORRIDOR

1FC1

ELEC

1F01

MECH

1F04

CORRIDOR

1FC2

ELEV MACH

1F02

STAIR

1FS2

SUPPLY STOR

1F03

ES-1

FS-4

FS-4

3" SS

3"

EWC-1

2"

T C

H

LI

N E

: 1 M

M A

T C

H

LI

N E

: 1 F

MATCHLINE: 1L

MATCHLINE: 1F

2"

2"

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

RECYCLE

1F05

M A

T C

H

LI

N E

: 1 K

M A

T C

H

LI

N E

: 1 L

M A

T C

H

LI

N E

: 1 D

D

D

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:0

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW116

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

F

IR

S T

F L

O O

R W

A S

T E

P A

L N

B

L O

C K

F

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909163

WET WET CLE

FIRST FLOOR WASTE PALN - BLOCK 1F

GCM

SHEET NOTES:

2" V FROM BELOW SLAB

2" SS FROM SECOND FLOOR

4" SS FROM SECOND FLOOR

4" SS DOWN TO BELOW SLAB

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

STAIR

1GS1 WC-2

WC-2

WC-1

L-1

S-1

D0680

CLINIC MGR

1G01

CORRIDOR

1GC4

OPS OFFICER

1G02

DIR DENTAL

SVCS

1G03 SEL OFC

1G04

TEAM COLLAB

1G05

CORRIDOR

1GC2

CORRIDOR

1GC1

CORRIDOR

1GC3

LPCO CLINIC

1G07

MANAGED

CARE

1G06

LACT RM

1G10

ST TLT

1G11

DTR-GEN

1H01

DTR-GEN

1H02

COMM RM

1H13

DTR-GEN

1H14

FCO

MATCHLINE: 1G

MATCHLINE: 1A

M A

T C

H

LI

N E

: 1 G

M A

T C

H

LI

N E

: 1 H

D0680

2" V

2"

2"

2" V UP

WCO

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

A

FCO

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:0

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW117

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

F

IR

S T

F L

O O

R W

A S

T E

P L

A N

B

L O

C K

G

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909164

WET WET CLE

FIRST FLOOR WASTE PLAN - BLOCK

1G

GCM

SHEET NOTES:

2" SS DOWN TO BELOW SLAB

3" SS DOWN TO BELOW SLAB

2" SS FROM SECOND FLOOR

3" SS FROM SECOND FLOOR

2" V FROM BELOW SLAB

2" V UP TO SECOND FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

L-4 L-4

WC-2

WC-2

L-4 L-4

WC-1

WC-1

L-1

WC-1

JC-1

EW-1

S-5

EW-1

D0680 D0680

D0680 D0680

D0680

D0680

D0680 D0680

D0680 D0680

D

DTR-GEN

1H01

DTR-GEN

1H03

DTR - GEN

1H07

DTR-GEN

1H09

ST TLT

1H11

CORRIDOR

1HC1

DTR-GEN

1H02

DTR-GEN

1H06

DTR-GEN

1H08

DTR-GEN

1H10

PT TLT

1H12

PT TLT

1H25

ELEC

1H23

DTR-GEN

1H21

DTR-GEN

1H19

DTR-GEN

1H15

COMM RM

1H13

CORRIDOR

1HC2

DTR-GEN

1H14

DTR-GEN

1H16

DTR-GEN

1H18

DTR-GEN

1H20

DTR-GEN

1H22 JAN CL

1H24

FCO

FCO

U-1 U-2 U-2

D0680

L-1

L-1

2" V 2" V 2" V

2" V 2" V

T C

H

LI

N E

: 1 G

M A

T C

H

LI

N E

: 1 H

M A

T C

H

LI

N E

: 1 H

M A

T C

H

LI

N E

: 1 J

D0680

DTR-GEN

1H05

2" V

DTR-GEN

1H04

D0680 D0680 D0680D0680D0680

3"

MATCHLINE: 1J

MATCHLINE: 1C

M A

T C

H

LI

N E

: 1 B

M A

T C

H

LI

N E

: 1 C

2" V

3" SS 3" SS

2" SS 2" SS

WCO

WCO

2" V

3" SS

2" V

M A

T C

H

LI

N E

: 1 B

M A

T C

H

LI

N E

: 1 C

2" V

2" V

2" S

S

3" SS

FCO2"

2" V

2"

WCO

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

2" V

B

M A

T C

H

LI

N E

: 1 A

1 1

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:1

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW118

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

F

IR

S T

F L

O O

R W

A S

T E

P L

A N

B

L O

C K

H

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909165

WET WET CLE

FIRST FLOOR WASTE PLAN - BLOCK

1H

GCM

SHEET NOTES:

2" SS FROM SECOND FLOOR

3" SS FROM SECOND FLOOR

2" V UP TO SECOND FLOOR

4" V UP TO SECOND FLOOR

3" SS DOWN TO BELOW SLAB

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

PANO-CEPH

1C04

PANO-CEPH

1C05

RAD OFC

1D13

L-2

WC-1

WC-1

L-1

WC-1

JC-1

EW-1

L-2

L-1

JC-1

S-5

EW-1

S-3 S-3

S-5

WC-1

EW-1

CAD/CAM

MILLING

1J01

DTR-GEN

1J03

DTR-GEN

1J07

CAD/CAM

MILLING

1J11

CORRIDOR

1JC1

MECH

1J15

CORRIDOR

1JC4

CORRIDOR

1JC2

DTR-GEN

1J12

MAIN COMM RM

1J02

DTR-GEN

1J04

DTR-GEN

1J06

DTR-GEN

1J08

DTR-GEN

1J10

CBCT

1J13

CORRIDOR

1JC3

PT TLT

1K01

JAN CL

1K02

FCO

D0680 D0680

L-2 L-2

L-1

DAC-1

DSV-1OE-1

SEP-2

SEP-1

OE-2

SEP-3

SEP-4

2" V

M A

T C

H

LI

N E

: 1 H

M A

T C

H

LI

N E

: 1 J

M A

T C

H

LI

N E

: 1 J

M A

T C

H

LI

N E

: 1 K

D0680D0680

MATCHLINE: 1J

MATCHLINE: 1C

MATCHLINE: 1K

MATCHLINE: 1D

DTR-GEN

1J09

2" V

44 4

2" SS

FS-4

FS-4

FS-4

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

DO NOT ROUTE PLUMBING

PIPING THROUGH ELEVATOR

SHAFTS, STAIRWELLS, DATA,

AND ELECTRICAL ROOMS.

(TYP.)

E

E

E

E

DTR-GEN

1J05

DNTG1

2"

1 2" V

2" V D0680

D0680

D0680

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:2

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW119

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

F

IR

S T

F L

O O

R W

A S

T E

P L

A N

B

L O

C K

J

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909166

WET WET CLE

FIRST FLOOR WASTE PLAN - BLOCK 1J

GCM

SHEET NOTES:

2" SS DOWN TO BELOW SLAB

3" SS DOWN TO BELOW SLAB

2" V UP FROM BELOW SLAB

2" SS FROM SECOND FLOOR

3" SS FROM SECOND FLOOR

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

RAD OFC

1D13

SOIL UTIL

1D15

EQ STOR

1D16

MED WASTE

1D17

GAS STOR

1D18

EW-1 EW-1

SS-1

L-1

JC-1

WC-1

S-5

WC-1

EW-1

D0680

D0680

CAD/CAM

MILLING

1J11

ELEC

1K15

PT TLT

1K01

DTR-GEN

1K03

DTR-GEN

1K05

DTR-GEN

1K09

DTR-GEN

1K11

CORRIDOR

1KC1

JAN CL

1K02

DTR-GEN

1K04

DTR-GEN

1K06

DTR-GEN

1K08

DTR-GEN

1K10

DTR-GEN

1K12

DTR-GEN

1K16

DTR-GEN

1K18

DTR-GEN

1K19

PT TLT

1K20

CORRIDOR

1KC2

FCO

FCO

L-2

L-1

2" V 2" V 2" V

M A

T C

H

LI

N E

: 1 J

M A

T C

H

LI

N E

: 1 K

M A

T C

H

LI

N E

: 1 K

M A

T C

H

LI

N E

: 1 L

2"

MATCHLINE: 1K

MATCHLINE: 1D

MATCHLINE: 1L

MATCHLINE: 1F

DTR-GEN

1J09

2" V 2" V

2" SS 2" SS

2" V 2" V

DTR-GEN

1K17

4"

DO NOT ROUTE PLUMBING

PIPING THROUGH ELEVATOR

SHAFTS, STAIRWELLS, DATA,

AND ELECTRICAL ROOMS.

(TYP.)

MATCHLINE: 1J

MATCHLINE: 1C

DTR-GEN

1K07

D0680 D0680 D0680 D0680

D0680 D0680 D0680 D0680

D0680 D0680 D0680 D0680

PM120 2" V

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/2024

2' 4' 8'

SCALE: 1/4"=1'-0"

P A

R R

IS

I S

L A

N D

S

C M

C R

D

P A

R R

IS

I S

L A

N D

N A

V A

L S

T A

T

IO

N

N O

R F

O L

K

V A

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

M

ID

L A

N T

D C

C O

R E

MT / SVR

EJA

DSN

Approved by Jason J. Root, NAVFAC / MFPO VIA SAT-TO Memo Dated 08/08/2024 Tracey Bond, Defense Health Agency VIA SAT-TO Memo Dated 08/19/2024

/2

/2

:1

:2

A

M

C

U s e rs \e lli o t.

te a g u e

\D o c u m e n ts \2

P e lli o t.

te a g u e D

Z A

G .r v t

1/4" = 1'-0"

SCALE: 1/4" = 1'-0"

PW120

P-7889

D E

N T

A L

C L

IN

IC

R E

P L

A C

E M

E N

T

F

IR

S T

F L

O O

R W

A S

T E

P L

A N

B

L O

C K

K

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A T

L A

N T

IC

12909167

WET WET CLE

FIRST FLOOR WASTE PLAN - BLOCK 1K

GCM

SHEET NOTES:

2" SS FROM SECOND FLOOR

3" SS FROM SECOND FLOOR

4" V UP TO SECOND FLOOR

2" SS DOWN TO BELOW SLAB

PROFESSIONAL

NO. 40396

A

A L

AB

A

M

N G

E

E

ENI

R

I G

E R

RE

D E

TS

E. T E A G

U E

W

I L

GAS STOR

1D18

ELEC

1F01

WC-1

L-1

WC-1

D0680

D0680

ST TLT

1L04

CORRIDOR

1LC1

LPO AND

SUPER GEN

DEN

1L02

OIC 2ND DET

1L01

SMALL TEAMS

1L05

2" SS

WCO

L-1

M A

T C

H

LI

N E

: 1 K

M A

T C

H

LI

N E

: 1 L

MATCHLINE: 1L

MATCHLINE: 1F

1 1

3"

3" SS

2"

2"

WCO

DO NOT ROUTE PLUMBING PIPING

THROUGH ELEVATOR SHAFTS,

STAIRWELLS, DATA, AND

ELECTRICAL ROOMS. (TYP.)

RECYCLE

1F05

M A

T C

H

LI

N E

: 1 D

PM120

FIRST FLOOR KEY PLAN

PLAN

NORTH

1A 1C 1F

1G 1J

1L 1H

1B

1K

1D

1M

112 113 114 115

120119118

A

B

C

D

1 2 3 4

1 2 3 4

A

B

C

D

SCALE:

PROJECT NO:

CONSTR CONTR NO:

NAVFAC DRAWING NO:

SHEET: OF

FIRE PROTECTION

CHIEF ENG/ARCH

BRANCH MGR

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

08/19/202…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .