- Bldg. AS518 Paint Booth Repairs
- Solicitation number
- N4008524R2728
About this file
This document appears to be a set of mechanical specifications and demolition notes related to a federal contract opportunity for repairs to a paint booth at Building AS518.
The key details are:
- This is a solicitation issued by the Department of the Navy Naval Facilities Engineering Command for mechanical MACC contractors to submit proposals for repairs to a paint booth in Building AS518.
- The mechanical specifications cover general requirements, demolition work, a mechanical legend, and duct construction and leakage testing details.
- The project requires removing and reinstalling existing mechanical equipment and ductwork, and disposing of demolished materials.
- Contractors must coordinate closely with the Contracting Officer to minimize disruptions during construction.
- All work must comply with applicable federal, state, and local codes and standards.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2246 Yaupon Drive Wilmington, NC 28401
Phone: 910.791.4000 Fax: 910.791.5266 www.cbhfengineers.com NC# P-0506c Copyright 2024CBHF Engineers, PLLC
Engineers, PLLC 043801
TROY O. GRADY
SEAL
R
EENI GN
P R
OF E S S I ON
A
E
L
NO
RT H CAROL I NA
1. ALL MECHANICAL WORK SHALL BE IN STRICT COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES
AND STANDARDS.
2. ALL DIMENSIONS AND ELEVATIONS FOR NEW EQUIPMENT, DUCTWORK, PIPING AND APPARATUS ARE APPROXIMATE AND ARE ONLY FOR CONTRACTOR'S GUIDANCE. CONTRACTOR SHALL SUBMIT DIMENSIONS AND ELEVATIONS VERIFIED IN THE FIELD. DUCTWORK AND PIPING INDICATED ON THE DRAWINGS, SECTIONS AND PROSPECTIVE VIEWS ARE SHOWN DIAGRAMMATICALLY. DUCT AND PIPE ELEVATIONS IN EXACT LOCATIONS SHALL BE DETERMINED BY THE INSTALLING
CONTRACTOR AND DETAILED ON THE SHOP DRAWINGS.
3. ALL DUCT DIMENSIONS INDICATED ON PLAN ARE CLEAR INSIDE DIMENSIONS. CONTRACTOR MUST ACCOUNT FOR THE
THICKNESS OF EXTERIOR INSULATION WHEN DETERMINING INSTALLATION CLEARANCES.
4. THE CONTRACTOR SHALL TEMPORARILY COVER ALL EXPOSED DUCT AND PIPE OPENINGS WITH A NON-COMBUSTIBLE MATERIAL, AND SEAL THEM AIR TIGHT TO PREVENT CONTAMINATION OF THE RESPECTIVE SYSTEMS DURING
CONSTRUCTION.
5. CONTRACTOR SHALL REMOVE AND DISPOSE OF OFFSITE ALL DEMOLISHED WORK IN ACCEPTABLE AND SAFE MANNER
AND SHALL KEEP ALL NON-WORK AREAS CLEAN AND SAFE.
6. ALL EXISTING EQUIPMENT AND CONNECTIONS THAT NEED TO BE TEMPORARILY DEMOLISHED FOR RIGGING AND / OR INSTALLATION SHALL BE REINSTALLED AND BROUGHT BACK TO ORIGINAL CONDITIONS PRIOR TO TEMPORARY
REMOVAL.
7. INSTALL WORK SO AS TO BE READILY ACCESSIBLE FOR OPERATION, MAINTENANCE AND REPAIR. MINOR DEVIATIONS FROM DRAWINGS MAY BE MADE TO ACCOMPLISH THIS, BUT CHANGES WHICH INVOLVE EXTRA COST SHALL NOT BE
MADE WITHOUT APPROVAL.
TERMABBREVIATION
AIR MOVEMENT AND CONTROL ASSOCIATIONAMCA
AMPERE (AMP, AMPS)AMP
COEFFICIENT OF PERFORMANCECOP
DEGREEDEG OR º
DRY BULBDB
EXHAUST GRILLEEG
ELECTRONICALLY COMMUTATED MOTORECM
ENERGY EFFICIENCY RATIOEER
FANF
FAHRENHEITºF
HEIGHTHGT OR H
HORSEPOWERHP
HOUR(S)HR
INCHES WATER GAUGEIN.-WG
KILOWATTKW
LOUVERL
MAXIMUMMAX
1000 BTUHMBH
MINIMUMMIN.
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONNEMA
OUNCEOZ
OUTSIDE AIROA
PERCENT%
POUNDSLBS
ROOF TOP UNITRTU
REVOLUTIONS PER MINUTERPM
SUPPLY AIRSA
SQUARESQ
UNIT HEATERUH
VOLT/PHASE/HERTZV/PH/HZ
WIDTHW
WET BULBWB
ADJUSTABLEADJ
EXTERNAL STATIC PRESSUREESP
FEETFT
INCHIN.
MINIMUM CIRCUIT AMPACITYMCA
MAXIMUM OVER CURRENT PROTECTIONMOCP
TRANSFER GRILLETG
ENTERING AIR TEMPERATUREEAT
LEAVING AIR TEMPERATURELAT
SQUARE-FEETSF
CUBIC FEET PER MINUTECFM
AMERICAN SOCIETY OF TESTING AND MATERIALSASTM
FULL LOAD AMPSFLA
TYPICALTYP
CONCRETE MASONRY UNITCMU
CAST IN PLACECIP
MEAN COINCIDENT WET BULBMCWB
MECHANICAL PIPE SYMBOLS
HWS
HWR
HEATING HOT WATER SUPPLY
HEATING HOT WATER RETURN
GM
INDICATES TO DEMOLISH
GAS METER
GAS SHUTOFF VALVE
EXTENT OF DEMOLITION
POINT OF CONNECTION
NOTE: ALL ITEMS MAY NOT BE USED IN PROJECT.
AIRFLOW, CFM
DIFFUSER/ REGISTER/ GRILLE NO. AS SHOWN
ON PLAN AND SCHEDULE
TEMPERATURE SENSORT
TEMPERATURE/HUMIDITY SENSORTH
1. THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND SPECIFICATIONS FOR DEMOLITION REQUIREMENTS AND LAYOUT HIS WORK IN A COMPATIBLE AND COMPLEMENTARY MANNER. REMOVE ALL EQUIPMENT, DUCTWORK, SUPPORTS, CONTROLS, ACCESSORIES, ETC..., AND MECHANICAL ITEMS MADE OBSOLETE BY THESE ALTERATIONS AS SHOWN IN THE MECHANICAL DRAWINGS. ALL ITEMS TO BE REMOVED OR MODIFIED MAY NOT BE SHOWN, HOWEVER, THIS CONTRACTOR SHALL REMOVE ANY MECHANICAL WORK AS REQUIRED BY THE CONSTRUCTION OR AS DIRECTED BY THE GOVERNMENT CONTRACTING OFFICER. SURVEY THE AFFECTED AREAS BEFORE SUBMITTING A BID.
2. SCHEDULING OF DEMOLITION - COORDINATE SCHEDULING OF MECHANICAL DEMOLITION WORK WITH THE CONTRACTING OFFICER SO AS TO MINIMIZE DISRUPTION OF THE GOVERNMENT'S USE OF THE FACILITIES AND MAINTAIN THE CONSTRUCTION SEQUENCE. SEE DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL INSTRUCTIONS CONCERNING
PHASING AND SEQUENCE OF WORK.
3. DEMOLISHED MATERIALS - UNLESS SPECIFICALLY REQUESTED BY THE GOVERNMENT, ALL DEMOLISHED MECHANICAL MATERIALS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE AND
DISPOSED OF PROPERLY.
4. CUTTING AND PATCHING - PERFORM CUTTING AND PATCHING FOR MECHANICAL WORK SO AS TO MINIMIZE DAMAGE TO
CEILINGS, FLOORS AND WALLS.
5. THESE DRAWINGS ARE COMPILED BY THE ENGINEER FROM THE GOVERNMENT'S AS-BUILT RECORD DRAWINGS AND LIMITED FIELD VERIFICATION OF EXISTING CONDITIONS FOR THE PURPOSE OF INDICATING THE WORK REQUIRED AND ARE BELIEVED TO BE CORRECT. NOTWITHSTANDING, THE CONTRACTOR SHALL VERIFY ALL DUCTWORK, EQUIPMENT
LOCATIONS, DIMENSIONS AND ALL FIELD CONDITIONS AFFECTING HIS WORK.
6. WHERE MECHANICAL SYSTEMS PASS THROUGH THE DEMOLITION AREAS TO SERVE OTHER PORTIONS OF THE PREMISES, THEY SHALL REMAIN OR BE SUITABLY RELOCATED AND THE SYSTEM RESTORED TO NORMAL OPERATION.
ADVISE THE CONTRACTING OFFICER IMMEDIATELY IF SUCH CONDITIONS ARE UNCOVERED BEFORE PROCEEDING WITH
ADDITIONAL WORK.
7. PROTECT ALL EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND PUBLIC ADDRESS SYSTEMS AND MAINTAIN THEM IN OPERATION THROUGHOUT THE PROGRESS OF THE WORK. NOTIFY THE CONTRACTING OFFICER IN WRITING IF SHUTDOWNS ARE REQUIRED PRIOR TO ANY OUTAGE OF SERVICE. WHERE THE DURATION OF A PROPOSED OUTAGE CANNOT BE TOLERATED BY THE GOVERNMENT, PROVIDE TEMPORARY CONNECTIONS AS REQUIRED MAINTAINING
SERVICE.
8. SURVEY THE AFFECTED AREAS BEFORE STARTING DEMOLITION AS ALL EXISTING CONDITIONS CANNOT BE
COMPLETELY DEPICTED ON THE DRAWINGS AND SOME UNUSUAL CONDITIONS EXIST.
9. IF ANY UNUSUAL STRUCTURAL OR ARCHITECTURAL CONDITIONS ARE ENCOUNTERED DURING DEMOLITION, CONTACT
THE CONTRACTING OFFICER FOR ASSISTANCE.
NOTE: ALL ABBREVIATIONS MAY NOT BE USED IN PROJECT.
NOTE: ALL ITEMS MAY NOT BE USED IN PROJECT.
HOT WATER COILHC
EXHAUST AIREA
RETURN AIRRA
SUPPLY GRILLESG
SG,RG,TG,EG
NOTE: ALL ITEMS MAY NOT BE USED IN PROJECT.
DROP
RISE
Ø
BD
SUPPLY DUCT TURNING DOWN
SUPPLY DUCT TURNING UP
INCLINED RISE WITH RESPECT TO AIRFLOW
DECLINED DROP WITH RESPECT TO AIRFLOW
CONICAL TEE
RADIUS ELBOW
INDICATES ROUND DUCTWORK
FLEXIBLE DUCT CONNECTION
MITERED ELBOW WITH TURNING VANES
MOTORIZED CONTROL DAMPER
BALANCING DAMPER
(ROUND OR RECTANGULAR)
(ROUND OR RECTANGULAR)
HORIZONTAL FIRE DAMPER
M
RETURN DUCT TURNING UP
(ROUND OR RECTANGULAR)
OUTSIDE AIR DUCT TURNING UP
(ROUND OR RECTANGULAR)
RETURN DUCT TURNING DOWN
(ROUND OR RECTANGULAR)
CEILING RETURN OR
TRANSFER REGISTER/GRILLES
VERTICAL FIRE DAMPER
CEILING SUPPLY DIFFUSERS
EXHAUST GRILLES
EXHAUST DUCT TURNING DOWN
(ROUND OR RECTANGULAR)
EXHAUST DUCT TURNING UP
(ROUND OR RECTANGULAR)
VERTICAL SMOKE DAMPER
VERTICAL FIRE/SMOKE DAMPER
FD
FD
SD
F/SD
ROUND DUCT TURNING DOWN
RECTANGULAR DUCT TURNING DOWN
WITH CHANGE OF DIRECTION
WITH CHANGE OF DIRECTION
TERMINATION OF DUCT WITH BRANCH CONNECTIONS
RECTANGULAR TO ROUND DUCT TRANSITION
SUPPLY AIR DUCTWORK
RETURN AIR DUCTWORK
EXHAUST AIR DUCTWORK
OUTSIDE AIR DUCTWORK
10X10 SQUARE OR RECTANGULAR DUCTWORK
VOLUME DAMPER
TAKEOFF WITH 45° THROAT
RETURN, EXHAUST OR TRANSFER AIR FLOW
SUPPLY AIR FLOW
DUCT CROSSING
SA
RA
EA
OA
MAKEUP AIR DUCTWORKMA
DUCT SMOKE DETECTORSD
P STATIC PRESSURE SENSOR
(ROUND OR RECTANGULAR)
OUTSIDE AIR DUCT TURNING DOWN
DPT DIFFERENTIAL PRESSURE TRANSDUCER
RETURN GRILLERG
DUCT SMOKE DETECTORD
VENT THROUGH ROOFVTR
HPS HIGH PRESSURE STEAM
(X)HPS EXISTING HIGH PRESSURE STEAM
HPC HIGH PRESSURE CONDENSATE
(X)HPC EXISTING HIGH PRESSURE CONDENSATE
BBD BOTTOM BLOW DOWN
CBD CONTINUOUS BLOW DOWN
BFW BOILER FEED WATER
EXISTING PUMPED CONDENSATE
NG NATURAL GAS
(X)PC
(X)CS EXISTING CHEMICAL FEED SUPPLY
3-WAY CONTROL VALVE
2-WAY CONTROL VALVE
BALL VALVE
BLOCK VALVE / SHUTOFF VALVE
GAUGE
PUMP
ANGLE VALVE
DRAIN
CHECK VALVE
GLOBE VALVE
FLOW TRANSMITTER
STEAM TRAP
RPZ
NC NORMALLY CLOSED
BOILER BLOWDOWN VALVE (SUPPLIED WITH BOILER)
BOILER STOP CHECK VALVE
FLANGED BUTTERFLY VALVE
FLANGE
FLOW MEASURING ORIFICE
FT
T
RPZ
MECHANICAL DUCTWORK LEGEND MECHANICAL GENERAL NOTES:
MECHANICAL DEMOLITION NOTES:
MECHANICAL LEGEND
MECHANICAL PIPE LEGEND
MECHANICAL ABBREVIATIONS
DUCT CONSTRUCTION AND LEAKAGE TESTING TABLE
SYSTEM
DUCT PRESSURE CLASS SUPPLY & EXHAUST
RETURN & OUTSIDE AIR DUCT TEST
PRESSURE
INCHES OF
WATER
COLUMN
NOTES
INCHES OF WATER ROUND/OVAL RECTANGULAR
SUPPLY DUCT
SUPPLY DUCT
(BETWEEN AHU
AND VAV)
SUPPLY DUCT
(DOWNSTREAM
OF VAV)
RETURN DUCT EXHAUST AND
RELIEF DUCT
OUTSIDE AIR
DUCT
DUCT SEAL
CLASS
DUCT LEAK
CLASS
DUCT SEAL
CLASS
DUCT LEAK
CLASS
DUCT SEAL
CLASS
DUCT LEAK
CLASS
PAINT BOOTH
EXHAUST - - - - -6 - A 3 A 6 - - 1 1
NOTES 1. TEST IN ACCORDANCE WITH SPECIFICATION SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC, AND WITH THE PROCEDURES IN SMACNA HVAC AIR DUCT LEAKAGE TEST MANUAL.
File details come from the government source that posted it. Updated .