230038 Transmittal Paint Booth.pdf

PDF 15 MB Posted

Attached to
Bldg. AS518 Paint Booth Repairs
Solicitation number
N4008524R2728
Issued by

About this file

This document is a 230038 Transmittal for Paint Booth Repairs for Building AS518. The related federal contract opportunity is Solicitation Number N4008524R2728 for Bldg. AS518 Paint Booth Repairs, issued by the Department of the Navy Naval Facilities Engineering Command.

The solicitation is only open to Mechanical MACC Contractors listed on the General Requirements cover page. The scope of work and any applicable drawings are provided in the attached documents. No other details about the required products or services, response dates, award dates, pricing terms, set asides, incumbents, or other salient information are included in the provided materials.

View the file

Other files

File Type Posted
23-0038 Existing Paint Booth Submittal.pdf PDF
Amend 0004 230038.pdf PDF
Amend 0003 230038.pdf PDF
23-0038 Amendment 0002.pdf PDF
60040515.pdf PDF
60040513.pdf PDF
23-0038 Upgrade AS518 Paint Booth to NESHAP Stds. Final Specifications 06-19-2024.pdf PDF
Amend 0001 230038.pdf PDF
60040517.pdf PDF
60040516.pdf PDF
60040520.pdf PDF
23-0038 AS518 MOD Div. 21 Specification.pdf PDF
60040514.pdf PDF
23-0038 AS518 MOD Div. 21 Submittal Register.pdf PDF
60040518.pdf PDF
60040511A.pdf PDF
60040519.pdf PDF
60040521A.pdf PDF
60040521.pdf PDF
60040511.pdf PDF
60040512.pdf PDF
N4008523B0038 Specs.pdf PDF
Mech MACC RFP.pdf PDF
N4008523B0038 Dwgs.pdf PDF
23-0038 APPD.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contract Number Transmittal Number Date

From Contractor Project Title and Location

To

Contractor Approved Government Approved Variation for Government Approval

Contractor's Comments

CONTRACTOR'S SUBMITTAL TRANSMITTAL

LANTDIV NORFOLK 4-4355/3 (Rev. 11-99)

CONTRACTOR USE ONLY REVIEWER USE ONLY

**ACTION CODES

A - Approved D - Disapproved AN - Approved as noted RA - Receipt acknowledged C - Comments R - Resubmit

*List only one specification division per form.

List only one of the following categories on each transmittal form, and indicate which is being submitted.

It em

N o Proj. Spec. Sect. &

Para. and/or Proj.

Dwg. No.

Item Identification (Type, size, model no., Mfg. Name, dwg. or brochure number) N o

. o f

C o p ie s

Action Codes

Reviewer Initials

Code Date

Copy of transmittal and submittals to ROICC Contractor Representative (Signature)

Date Received by Reviewer From (Reviewer) To

Submittals are returned with action indicated. Approval of an item does not include approval of any variation from the contract requirements unless the contractor calls attention to and supports the variation.

Submittals are forwarded to ROICC with A-E recommendations indicated in REVIEWER USE ONLY section and in coments below on ONE COPY of the transmittal form.

Reviewer's Comments

Copies To:

ROICC (2)

LANTDIV (1)

A-E (1)

Date Signature

EFDLANT

Submittal Transmittal

2246 Yaupon Dr. Wilmington NC 28401 United States

PROJECT: Buildings AS508, AS518 and G640 20037

DATE SENT: 10/26/2021

SUBJECT: 23 73 33 Paint Booth Shop Drawings - #021C

SUBMITTAL ID: #021C

TYPE: Submittal TRANSMITTAL ID: 00031

PURPOSE: Revise and Resubmit VIA: Email

SPEC SECTION: 23 73 33

FROM

NAME COMPANY EMAIL PHONE

Robert Wilson rwilson@cbhfengineers.

com

TO

NAME COMPANY EMAIL PHONE

Steven McNeill MCBCL, Public Works Division steven.mcneill@usmc.m il

(910) 451-3658 ,,,3294

Joseph Orr MCB Camp Lejeune joseph.orr@usmc.mil (910) 451-3658 ex:3261

REMARKS:

Response (Revise and Resubmit) from: Troy Grady Remarks:

Electrical comment:

The MOP is indicated as 125 amps and 70 amps in two different locations within the submittal, which one is correct?

Public Works Comments:

Does the control panel come with a booth temperature display as shown on Drawing M-602? I could not tell.

Which leads me to ask, do they have a control panel drawing to reference? I would think they would need one To illustrate / show this below. I can trace out some of the ladder logic but can’t piece the displays as definitive.

They really need to have a panel drawing showing they are doing this in my opinion.

Submittal Transmittal

DATE: 10/26/2021

ID: 00031

2. Does the control panel come with a booth pressure display as shown on Drawing M-602?

3. Does the control panel come with a cure time temperature.

4. Does the system come with a BACnet MS/TP controller. Drawing on page 50 shows Cat 5e Connections going into a main module. If this is a BACnet IP device there needs to be a BACnet MS/TP gateway in place to do the conversion from BACnet IP to BACnet MS/TP. They Did not submit any controller information so it’s hard to tell.

Submittal Transmittal

DATE: 10/26/2021

ID: 00031

CONTENTS

QUANTITY: 1 DATED: 10/5/2021 NUMBER:

DESCRIPTION:

Transmittal #021C -N4008520D0079 - Paint Booth.pdf

ACTION:

REMARKS:

OF-20210008.0 Page 1 of 5

Contractor license: WA# ROHNEMI015LH, OR # 135549, CA# 792654

O.F. (Official Response)

Date: 11/12/2021

Project: Buildings AS508, AS518 and G640 20037.Paint Shop

RFI #: R2021008.0

Attn: Dave Suggs

Response to (Revise and Resubmit, Submittal ID: #021C)

Paint Booth.

Response (Revise and Resubmit) from: Troy Grady Remarks:

Electrical comment:

The MOP is indicated as 125 amps and 70 amps in two different locations within the submittal, which one is correct?

Answer: The Titan unit has an internal disconnect rated at 60A for the load of the AHU. The MOP of the

Titan unit is 75A. After consulting MFIA, they informed us that the 60A disconnect is sized correctly, and the building feeder breaker needs to also be sized to match this at 60A. Feeder conduit/wire should be sized at <70-4>.

Public Works Comments:

Does the control panel come with a booth temperature display as shown on Drawing M-602? I could not tell.

Which leads me to ask, do they have a control panel drawing to reference? I would think they would need one To illustrate / show this below. I can trace out some of the ladder logic but can’t piece the displays as definitive.

They really need to have a panel drawing showing they are doing

Yes, Included is the Titan controls with displays.

Provided is page 51 of the schematics with Carel PC142 will be the connection point for the BMS Bacnet to Titan.

OF-20210008.0 Page 2 of 5

OF-20210008.0 Page 3 of 5

OF-20210008.0 Page 4 of 5

R20210008 - SILER - Camp Lejeune Camp Lejeune, North Carolina

SUBMITTAL PACKAGE

FROM: (Contractor)

NEW

SECTION

NO.

REV APPROVED INITIAL

1 C

1 C

1 C

1 C

1 C

1 C

1 C

1 C

2 C

3 B

3 A

SHT 0 - Iso View of Booth Isometric view of equipment

SHT 1 - Plan View

SPECIFICATION SECTION/

DRAWING NO.

DESCRIPTION OF MATERIAL

David Snuggs ROHNER INC 9/2/2021

JOB NUMBER: PROJECT NAME: SUBMITTAL:

R20210008 Paint booth AS518 – Marine Corps

Base, Camp Lejeune

RESUBMITAL

Equipment plan sht.

Isometric view of equipment

SHT 3.2 Iso View

BY COMPLETING THIS FORM. THE UNDERSIGNED CONTRACTOR CERTIFIES THAT THE EQUIPMENT COMPLIES WITH ALL

SPECIFICATIONS OF SUBJECT CONTRACT

DATE: (MM/DD/YYYY) TYPE OR PRINT NAME AND TITLE SIGNATURE

SHT M2 - Mechanical Specifications

Mechanical Specs.

Isometric view of equipment

SHT 3.1 - Titan Schematic Titan AMU Schematic Drawing

EQUIPMENT APPROVAL SUBMITTAL

DATE: (MM/DD/YYYY)TO: (Contracting officer)

SHT E1 - Electrical One Line Electrical One Line Drawing

SHT S1 - Structural Drawings Structural Drawings

SHT M1 - Duct & Mechanical Schedule

Ductwork & Mechanical details

Item Specification Packet Specification Sheets for job related materials

SHT S2 Structural Detail Structural Drawing Details

SHT 2 - Exploded Iso View

1 7/30/2021 A KH

1 7/30/2021 A KH

1 7/30/2021 A KH

1 7/30/2021 A KH

2 7/30/2021 A KH

2 7/30/2021 A KH

3 7/31/2021 A KH

1 8/6/2021 B KH

1 8/6/2021 B KH

3 8/6/2021 B KH

1 9/2/2021 C KH

1 9/2/2021 C KH

1 9/2/2021 C KH

1 9/2/2021 C KH

1 9/2/2021 C KH

2 9/2/2021 C KH

2 9/2/2021 C KH

INITIAL

(NUMBER TO CORRESPOND WITH APPLICABLE ITEM NUMBER ON REVERSE)

SECTION

E1 updated with correct AHU motor HP and stamped

Sheets 0, 1, 2, 3.2, S1, M1, M2 updated with new AMU

Sheets 0, 1, 2, 3.2, S1, M1, M2 updated with relocated exhaust fan

Re-stamped sheets S1, M1, M2

DATE REV.

COMMENTS

Page 2.7 Air Solenoid Valve updated to correct part number

Burner Firing Rate corrected on M2

Page 2.1a AMU updated

Page 2.2 Exhaust fan updated

Sheets 0,1,2,3.2,S1,S2,M1,M2 updated w/ new booth dimensions

Sheets 0,1,2,3.2,S1,S2,M1,M2 updated w/ relocated AMU and Duct

Sheets 0,1,2,3.2,S1,S2,M1,M2 updated w/ relocated Exhaust fan & Duct box

M1 and M2 re-stamped

S1 and S2 re-stamped

2.1a Titan AMU drawing updated

Sheet 3.1 Titan Schematic added

Updated SHT 1 Exhaust VFD HP to 7.5

M2 drawing updated; AHU S.P, motor HP, NEC FLA, Unit FLA and stamped

Section 1 Revisions:

A. 07-30-21 – 1. Sheets 0, 1, 2, 3.2, S1, M1, M2 updated with side discharge Titan AMU and new Duct layout with relocated exhaust fan. Re-stamped S1, M1, M2, Burner Firing Rate corrected on M2.

B. 08-06-21 –1. Sheet 1 updated Exhaust VFD hp. Sheet M2 updated S.P., Motor Hp, NEC FLA, Unit FLA and re-stamped.

C. 09-02-21 – 1. Sheets 0, 1, 2, 3.2, S1, S2, M1, M2 updated w/ relocated AMU and Duct layout, relocated exhaust fan and duct box. Re-stamped M1, M2, S1, S2. AMU and exhaust fan CFM changed from 24,000 to 22,000. Booth dimensions changed and reflected in all sheets mentioned above.

Drawing Index

Sheet 0 Iso View of Booth

Sheet 1 Booth Plan View

Sheet 2 Exploded Iso View of Booth

Sheet 3 N/A

Sheet 3.2 Iso View

Sheet 4 N/A

Sheet S0 N/A

Sheet S1 Structural Drawings

Sheet S2 Structural Detail

Sheet M1 Duct & Mechanical Layout

Sheet M2 Mechanical Specifications

Sheet M3 N/A

ISSUED DATE:

DRAWN BY:

CHECKED BY:

JOB NO:

DRAWING TITLE:

R O

H N

E R

M

C H

A N

I C A L

I N

C

D B A

R

O H

N E R

N

E

A N

D R

E S

N

D

S U

I T E

V A N

C O

U V E R

W

A

V O

I C E

F A X

W A

L I C

O H

N E M

I L H

O R

L I C

C A

W W

W R

O H

N E R

U

S A C

SHEET NO:

EQUIP. NO:

C 2007- 2014 ROHNER ALL RIGHTS

RESERVED.

THIS DOCUMENT AND THE IDEAS

EXPRESSED HEREIN ARE THE

EXCLUSIVE PROPERTY OF ROHNER

AND IS NOT TO BE REPRODUCED

IN ANY MANNER WITHOUT

THE EXPRESS WRITTEN

AUTHORIZATION OF ROHNER.

REV:

DESCRIPTION OF CHANGE(S):

R20210008

MCD-RLWP-24-10-40-FCP

KDK

09/02/2021

EXPLODED ISOMETRIC

ASSEMBLY DRAWING

- ISOMETRIC VIEW OF BOOTH

A

C U

S T O

M

I N

D U

S T R I A L

M

O D

I F I

C

O S S

D

R A F T

B O

O T H

F

R

M ar in e

Co rp s A ir

St at io n

N ew

R iv er , J ac ks on vi lle , N

C

S I L E

R

C

A M

P

L E

J E

U N

E

Pa in t B oo th b ui ld in g is

AS

Ca m pb el l S t.

INITIAL RELEASE

21.1 - 09/02/2021

XXX

READ PRIOR TO SIGNING!

Rohner engineering specifications shown on this approval drawing may differ from the equipment quotation. Please review all specifications on this approval drawing and compare to your signed quotation or purchase order. By signing this approval drawing the purchaser accepts these specifications in lieu of the quotation specifications and releases the equipment to be manufactured as shown in this drawing. Any changes requested after release to production will result in an upcharge of 5% of the total contract amount plus all additional design, engineering and materials cost plus normal gross profit margin.

APPROVAL

APPROVED FOR CONSTRUCTION WITH

NO CHANGES REQUIRED.

NOT APPROVED FOR CONSTRUCTION,

REQUIRES NEW SUBMITTAL DRAWINGS.

GAS SUPPLY: NATURAL GAS PROPANE

POWER SUPPLY VOLTAGE REQUIRED:

208V 230V 460V

1 3

LIGHTING: 120V 277V

NOTE: EQUIPMENT REQUIRES A HIGH PRESSURE

STEPDOWN REGULATOR SUPPLIED BY OTHERS WITH

OUTPUT OF ½ PSI (14" W.C.) AT THE MIDPOINT OF THE

ADJUSTMENT WITHIN 10' OF EQUIPMENT. ½ PSI (14"

W.C.) MINIMUM IS REQUIRED TO ACHIEVE RATED UNIT

BTUH OUTPUT. REGULATOR SHOULD BE LOCATED NO

CLOSER THAN 2' AND NO FURTHER THAN 10' OF EQUIPMENT

CONNECTION POINT.

COMPANY DATE

AUTHORIZED SIGNATURE TITLE

DIMENSIONS/DETAILS WITH AN * DENOTE A DESIGN

CHANGE FROM CONTRACT

LEGEND

SHEET 0 - ISOMETRIC VIEW / LEGEND / APPROVAL STAMP

SHEET 1 - BOOTH PLAN VIEW

SHEET 2 - EXPLODED ISOMETRIC VIEW

SHEET S0 - STRUCTURAL CALCULATION

SHEET SE1 - STRUCTURAL DRAWING

SHEET M1 - DUCT & MECHANICAL LAYOUT

SHEET M2 - MECHANICAL SPECIFICATIONS

SHEET E1 - ELECTRICAL ONE LINE

CHECKED BY:

JOB NO:

DRAWING TITLE:

R O

H N

C H

A N

I C A L

I N

C

D B A

R

O H

N E R

N

E

A N

D R

E S

S U

I T E

V A N

C O

U V E R

W

A

V O

I C E

F A X

W A

L I C

H

N E M

I L H

O R

L I C

C

W W

W R

O H

N E R

U

S A C

C 2007- 2014 ROHNER ALL RIGHTS

RESERVED.

THIS DOCUMENT AND THE IDEAS

EXPRESSED HEREIN ARE THE

EXCLUSIVE PROPERTY OF ROHNER

AND IS NOT TO BE REPRODUCED

IN ANY MANNER WITHOUT

FRONT VIEW

3/16"= 1'-0"

PLAN VIEW

3/16"= 1'-0"

RIGHT VIEW

3/16"= 1'-0"

REAR VIEW

3/16"= 1'-0"

KDK

MCD-RLWP-24-10-40-FCP

EXPLODED ISOMETRIC

ASSEMBLY DRAWING

- BOOTH PLAN VIEW

09/02/2021

R20210008

21.1 - 09/02/2021

INITIAL RELEASE

Pa in t B oo th b ui ld in g is

AS

Ca m pb el l S t.

M ar in e

Co rp s A ir

St at io n

N ew

R iv er , J ac ks on vi lle , N

C

S I L E

R

C

A M

P

L E

J E

U N

E

A

C U

S T O

M

I N

D U

S T R

I A L

M

O D

I F I

O

S S

D

R A F T

B O

O

R

LEFT VIEW

3/16"= 1'-0"

XXX

42'-9 1/8" OVERALL DIMENSION ( O.D. )

38'-4" WORKING DIMENSION ( W.D. )

O

D

W

D

9'-0" CLEAR OPENING 9'-0" CLEAR OPENING 9'-0" CLEAR OPENING 9'-0" CLEAR OPENING

M

I N

I M

U

F I E L

V

R I F Y

O

D

W

S T R U

C T U

R E

O

D

9'-11 7/8"

CHECKED BY:

JOB NO:

DRAWING TITLE:

R O

H N

C H

A N

I C A L

I N

C

D B A

R

O H

N E R

N

E

A N

D R

E S

S U

I T E

V A N

C O

U V E R

W

A

V O

I C E

F A X

W A

L I C

H

N E M

I L H

O R

L I C

C

W W

W R

O H

N E R

U

S A C

C 2007- 2014 ROHNER ALL RIGHTS

RESERVED.

THIS DOCUMENT AND THE IDEAS

EXPRESSED HEREIN ARE THE

EXCLUSIVE PROPERTY OF ROHNER

AND IS NOT TO BE REPRODUCED

IN ANY MANNER WITHOUT

R20210008

MCD-RLWP-24-10-40-FCP

KDK

09/02/2021

EXPLODED ISOMETRIC

ASSEMBLY DRAWING

EXPLODED ISO VIEW

OF BOOTH

A

C U

S T O

M

I N

D U

S T R I A L

M

O D

I F I

O S S

D

R A F T

B O

O

R

M ar in e

Co rp s A ir

St at io n

N ew

R iv er , J ac ks on vi lle , N

C

S I L E

R

C

A M

P

L E

J E

U N

E

Pa in t B oo th b ui ld in g is

AS

Ca m pb el l S t.

INITIAL RELEASE

21.1 - 09/02/2021

XXX

FILTERED CEILING WITH CLASS I DIV II LIGHTS

FILTERED SUPPLY PLENUM

REAR WALL EXHAUST PLENUM

9'X9' PRODUCT DOOR TYP.

EXPLODED ISOMETRIC VIEW

ALL DUCT MECHANICAL AIR UNITS NOT SHOWN FOR CLARITY

PARTS LIST

DESCRIPTIONPART NUMBERQTYITEM

42" Diameter Tube Axial FanTBA-4211

Make up Air Unit TA-127-VRH-0112

24VDC power supply, 24 I/O PLC controller, PID temperature control relay with fuzzy logic and auto tuning & 5.7” QVGA color touch screen HMI. (1) 20 hp. Supply blower VFD and (1) 7.5 hp. exhaust fan VFD(s) with auto booth pressure control.

Compact PLC based control center

ISSUED DATE:

DRAWN BY:

CHECKED BY:

JOB NO:

DRAWING TITLE:

R O

H N

C H

A N

I C A L

I N

C

D B A

R

O H

N E R

N

E

A N

D R

E S

S U

I T E

V A N

C O

U V E R

W

A

V O

I C E

F A X

W A

L I C

H

N E M

I L H

O R

L I C

C

W W

W R

O H

N E R

U

S A C

C 2007- 2014 ROHNER ALL RIGHTS

RESERVED.

THIS DOCUMENT AND THE IDEAS

EXPRESSED HEREIN ARE THE

EXCLUSIVE PROPERTY OF ROHNER

AND IS NOT TO BE REPRODUCED

IN ANY MANNER WITHOUT

R20210008

MCD-RLWP-24-10-40-FCP

3.2

KDK

09/02/2021

EXPLODED

ISOMETRIC

ASSEMBLY

DRAWING

- DEVICE LOCATIONS

1. UNLESS OTHERWISE NOTED:

A. PANEL-TO-PANEL FASTENING TO USE 1/4-20X3/4" HEX BOLTS AND NUTS.

B. PANEL-TO-TUBE STEEL FASTENING TO USE 1/4-20x1", SELF-DRILLING SCREW.

C. PANEL-TO-RIB STRUCTURE FASTENING TO USE 1/4-20X3/4" HEX BOLTS AND

NUTS.

D. RIB STRUCTURE-TO RIB STRUCTURE FASTENING TO USE 5/8-11X1 1/2" HEX

BOLTS AND NUTS.

E. RIB ANCHOR-TO-CONCRETE FASTENING TO USE 1/2"X5 1/2" WEDGE ANCHORS,

(2) PER RIB ANCHOR (TO BE SUPPLIED BY INSTALLER).

F. PRODUCT DOOR HINGE-TO-TUBE STEEL FASTENING TO USE 1/4-20X1"

SELF-DRILLING SCREW.

GENERAL NOTES:

U

S T O

M

I N

D U

S T R I A L

M

O D

I F I

O S S

D

R A F T

B O

O

R

M ar in e

Co rp s A ir

St at io n

N ew

R iv er , J ac ks on vi lle , N

C

S I L E

R

C

A M

P

L E

J E

U N

E

Pa in t B oo th b ui ld in g is

AS

Ca m pb el l S t.

INITIAL RELEASE

21.1 - 09/02/2021

XXX

EXHAUST FAN EF1

(3) COMPACT PLC BASED CONTROL CENTER

IS TIED TO THE AIR MAKE UP AIR UNIT

GENERAL

CODE REQUIREMENTS:

CONFORM TO THE CURRENT NORTH CAROLINA BUILDING CODE WHICH AMENDS THE 2015 INTERNATIONAL BUILDING

CODE (IBC).

EXISTING CONDITIONS:

ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS SHALL BE FIELD VERIFIED. THE CONTRACTOR SHALL NOTIFY KPFF OF ANY SIGNIFICANT DISCREPANCIES FROM CONDITIONS SHOWN ON THE DRAWINGS. CONCRETE FOUNDATION WORK IS NOT PART OF THESE DOCUMENTS AND SHALL BE PROVIDED AND VERIFIED BY OTHERS. THIS

STRUCTURE IMPARTS LOADING ONTO THE STRUCTURE BELOW WITH THE FOLLOWING REACTIONS:

INTERIOR FRAME COLUMN

END FRAME COLUMN

MEMBER

DEAD LOAD LIVE LOAD WIND LOAD SEISMIC LOAD

H V 200 1000

100 500

H V 400 -200

200 100

H V N/A N/A

N/A N/A

H V 100 -100

50 -50

LOADS SHOWN ARE IN POUNDS AND UNFACTORED. H INDICATES HORIZONTAL LOADING AND V INDICATES VERTICAL

LOADING. NEGATIVE (-) VERTICAL LOADS ARE UPWARD.

DESIGN CRITERIA

DESIGN WAS BASED ON THE STRENGTH AND DEFLECTION CRITERIA OF THE CODE NOTED ABOVE. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND ALLOWABLES WERE USED FOR DESIGN: STRUCTURE IS LOCATED INDOORS

AND THEREFORE NO WIND LOADING IS APPLIED. NO ADDITIOAL LOADING IS ALLOWED

GRAVITY SYSTEM CRITERIA

OCCUPANCY OR USE UNIFORM LOAD CONCENTRATED LOAD

MAINTENANCE ACCESS NONE 250 LB

INTERIOR LATERAL LOAD 5 PSF -

SEISMIC CRITERIA

RISK CATEGORY II

SEISMIC DESIGN CATEGORY B

SITE CLASS D (ASSUMED)

IMPORTANCE FACTOR IE = 1.0

MCE SPECTRAL ACCELERATION Ss = .114 S1 = .055

SITE COEFFICIENT Fa = 1.6 Fv = 2.4

DESIGN SPECTRAL ACCELERATION SDS = .121 SD1 = .088

ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PER ASCE 7-16, SECTION 12.8

X DIRECTION (EAST / WEST) Y DIRECTION (NORTH / SOUTH)

SEISMIC FORCE RESISTING SYSTEM

(SFRS)

STEEL SYSTEMS NOT SPECIFICALLY

DETAILED FOR SEISMIC RESISTANCE

STEEL SYSTEMS NOT SPECIFICALLY

DETAILED FOR SEISMIC RESISTANCE

RESPONSE MODIFICATION FACTOR R = 3 R = 3

STRUCTURAL STEEL

STRUCTURAL STEEL SHALL BE OF THE MATERIAL AND TYPE LISTED BELOW, U.N.O.:

STRUCTURAL STEEL

SHAPE MATERIAL GRADE

ALL PLATE MATERIAL ASTM A653, GRADE 50

ANGLES AND CHANNELS ASTM A36

WIDE FLANGES ASTM A992

BOLTS SHALL BE SAE J429 GRADE 5 BOLTS, SNUG-TIGHT.

HOLLOW STRUCTURAL SECTIONS (HSS) ASTM A500, GRADE C (Fy = 50 KSI)

SPECIAL INSPECTIONS

SPECIAL INSPECTION WILL BE PROVIDED BY THE OWNER BASED ON THE REQUIREMENTS OF THE CODE NOTED ABOVE AND AS SUMMARIZED IN THE SPECIAL INSPECTION PROGRAM TO FOLLOW. CONTRACTOR SHALL PROVIDE SUFFICIENT

NOTICE AND ACCESS FOR THE SPECIAL INSPECTOR TO PERFORM THESE INSPECTIONS.

SYSTEM OR MATERIAL

FREQUENCY (NOTE 6)

REMARKS

CONTINUOUS PERIODIC

POST INSTALLED MECHANICAL

ANCHORS AND ADHESIVE

ANCHORS

X

SPECIAL INSPECTIONS OF ANCHORS

SHALL CONFORM TO THE ANCHOR(S)

ICC REPORT(S)

S2.0

D O

U B

L E

G a R

O H

N E

R R

IB

F

R A

U B

L E

G a R

O H

N E

R R

IB

F

R A

U B

L E

G a R

O H

N E

R R

IB

F

R A

U B

L E

G a R

O H

N E

R R

IB

F

R A

U B

L E

G a R

O H

N E

R R

IB

F

R A

14Ga. STRAP

AT MID SPAN.

REF 6/S2.0

S2.0

TYP.

S2.0

TYP.

S2.0TYP.

18Ga. ROHNER

CEILING PANELS

(BY OTHERS)

LIGHT FIXTURE

BELOW

(BY OTHERS)

EXHAUST FAN AND

DUCT WORK.

(BY OTHERS)

S2.0

TYP.

R O

H N

ER

R

IB

F R

AM

E

D O

U

BLE

0"

2G a

R O H N E R R

IB

FR

A M

E

D O U

BLE

10" 12G a

R O H N E R R

IB

FR

A M

E

D O U

BLE

10" 12G a

R O H N E R R

IB

FR

A M

E

D O U

BLE

10" 12G a

R O H N E R R

IB

FR

A M

E

D O U

BLE

10" 12G a

R O H N E R R

IB

FR

A M

E

D O U

BLE

10" 12G a

R O

H N

ER

R

IB

F R

AM

E

D O

U

BLE

0"

2G a

R O

H N

ER

R

IB

F R

AM

E

D O

U

BLE

0"

2G a

R O

H N

ER

R

IB

F R

AM

E

D O

U

BLE

0"

2G a

R O

H N

ER

R

IB

F R

AM

E

D O

U

BLE

0"

2G a

TYP.

9' - 7"

/4

EXPIRES 12-31-21

N O

R

TH CAROLIN

A

P R

O

FE SS ION

A L

E N

G I N E E

RM

ARK TO B I N

048476

SEAL

W.

S

W F if th

A v e

S u it e

P o rt la n d

O

R

O

.2

.3

F

.2

.7 w w w .k p ff

.c o m

CONSTRUCTION SET

ISSUED DATE:

DRAWN BY:

CHECKED BY:

JOB NO:

DRAWING TITLE:

R O

H N

E R

M E C H

A N

IC

A L

IN

C

D .B

.A

"R O

H N

E R

N

E A

N D

R E S E N

R D

S U

IT

E

V A N

C O

U V E R

W A

(3

-7

V

O

IC

E

(3

-5

F

A X

W A

L

IC

H N

E M

I0 L H

O R

L

IC

C A

W W

W .R

O H

N E R

-U S A .C

O M

EQUIP. NO:

C 2007- 2014 ROHNER ALL RIGHTS

RESERVED.

THIS DOCUMENT AND THE IDEAS

EXPRESSED HEREIN ARE THE

EXCLUSIVE PROPERTY OF ROHNER

AND IS NOT TO BE REPRODUCED

IN ANY MANNER WITHOUT

THE EXPRESS WRITTEN

AUTHORIZATION OF ROHNER.

REV:

DESCRIPTION OF CHANGE(S):

SHEET NO:

TL

AJB

06/02/2021

/3

/2

:4 :1

P

M

C

R

E V

IT

\1 th o n g .l a m k p ff .c o m

.r v t

S1.0

10022100329

FRAMING PLANS

AND GENERAL

STRUCTURAL

NOTES

C A M

P L

E

JU

N E

A S C a m p b e ll

S t.

M a ri n e C o rp s A ir S ta ti o n

N e w

R iv e r, J a ck so n v ill e N

C

A C

U S T O

M B

A T C H

P O

W D

E R B

O O

T H

W

IT

H C

O L L E C T O

R M

O D

U L E F

O R

3/8" = 1'-0"2

ROOF FRAMING PLAN

3/8" = 1'-0"1

BASE TRACK PLAN

3 1/8" 8"

-5

R

IB

D E

P T

H

(1) 10GA. CORNER

PLATES EACH SIDE.

(2) TOTAL

(8) 1/2" THRU BOLTS

DOUBLE RIBS

BACK TO BACK

REF. PLAN

(1) 10GA. CORNER

PLATES EACH SIDE.

(2) TOTAL

SECTION A-A

A

A

/2

/4

2"

14GA. STRAPS AT

TOP OF COLUMNS

/4

2 1/2" 2 1/2"

2 1/2" 2 1/2"

N O

T E

D

D E

P T

H A

S

1/4" - 20 BOLTS @ 6" o.c.

TYP

RIB FRAME

COLUMN

REF. PLAN

BENT PL 3/16x4x2 1/4x0'-6" w/(2)1/2" BOLTS

(4) 1/2" SIMPSON

STRONG- BOLT 2

w/ 2 3/4" MIN.

EMBEDMENT

BOLTS MUST BE NO

LESS THAN 1'-0" FROM

EDGE OF SLAB IN ANY

DIRECTION

SECTION A-A

A

1/4" RED HEAD

HAMMERSET NAIL

ANCHORS w/ 3/4"

EMBEDMENT EACH

END AND MIDDLE

OF WALL PANEL

ROHNER WALL

PANEL

RIB FRAME

COLUMN

REF. PLAN

A

(E) CONC. BY OTHERS

MIN. 3 KSI

3" 1 1/2"

1/4" BOLTS

@ 8" o.c.

ROHNER WALL

PANEL

1/4" BOLTS

@ 8" o.c.

M

IN

S2.0

ROHNER DOUBLE

RIB FRAME

REF PLAN

/8

/8

18Ga. ROHNER

WALL PANEL

(BY OTHERS)

ROHNER WALL

PANEL

1/4"-20 BOLTS

@ 6" o.c.

SANDWICH PANEL

TAB BETWEEN

DOUBLE RIB

STRUCTURE

(2) L2x2 1/2x3/16 LLH

ROHNER DOUBLE

RIB FRAME

ROHNER ROOF

PANEL

ROHNER ROOF

PANEL

1/4"-20 BOLTS

@ 6" o.c.

SANDWICH PANEL

TAB BETWEEN

DOUBLE RIB

STRUCTURE

(4) #12 SCREWS

TO BEAM/COLUMN

DOUBLE RIB

REF. PLAN

1 1/4"x14 GA. STRAP

(5) #12 SCREWS

TO PANEL OR

ANGLEROHNER PANEL

OR ANGLE

1 1/2" = 1'-0"2

DOUBLE RIB FRAME CORNER

CONN. - SINGLE PL

3" = 1'-0"4

ROHNER DOUBLE RIB SECTION

EXPIRES 12-31-21

N O

R

TH CAROLIN

A

P R

O

FE SS ION

A L

E N

G I N E E

RM

ARK TO B I N

048476

SEAL

W.

S

W F if th

A v e

S u it e

P o rt la n d

O

R

O

.2

.3

F

.2

.7 w w w .k p ff

.c o m

CONSTRUCTION SET

ISSUED DATE:

DRAWN BY:

CHECKED BY:

JOB NO:

DRAWING TITLE:

R O

H N

E R

M E C H

A N

IC

A L

IN

C

D .B

.A

"R O

H N

E R

N

E A

N D

R E S E N

R D

S U

IT

E

V A N

C O

U V E R

W A

(3

-7

V

O

IC

E

(3

-5

F

A X

W A

L

IC

H N

E M

I0 L H

O R

L

IC

C A

W W

W .R

O H

N E R

-U S A .C

O M

EQUIP. NO:

C 2007- 2014 ROHNER ALL RIGHTS

RESERVED.

THIS DOCUMENT AND THE IDEAS

EXPRESSED HEREIN ARE THE

EXCLUSIVE PROPERTY OF ROHNER

AND IS NOT TO BE REPRODUCED

IN ANY MANNER WITHOUT

THE EXPRESS WRITTEN

AUTHORIZATION OF ROHNER.

REV:

DESCRIPTION OF CHANGE(S):

SHEET NO:

TL

AJB

06/02/2021

/3

/2

:4 :1

P

M

C

R

E V

IT

\1 th o n g .l a m k p ff .c o m

.r v t

S2.0

10022100329

BOOTH DETAILS

C A M

P L

E

JU

N E

A S C a m p b e ll

S t.

M a ri n e C o rp s A ir S ta ti o n

N e w

R iv e r, J a ck so n v ill e N

C

A C

U S T O

M B

A T C H

P O

W D

E R B

O O

T H

W

IT

H C

O L L E C T O

R M

O D

U L E F

O R

1 1/2" = 1'-0"3

RIB COLUMN BASE CONNECTION

3/8" = 1'-0"1

ELEVATION

3" = 1'-0"5

ROOF STEP

1 1/2" = 1'-0"6

WF STRAP BRACING CONN.

AutoCAD SHX Text 6-8-2021

EQUIPMENT SUPPORT STAND BY STRUCTURAL ENGINEER

6-8-2021

Section 2 Revisions:

A. 07-30-2021 – 1. Page 2.7 Air Solenoid Valve changed from ¾” to 1 ¼” connection, 2.1a Titan AMU drawing updated.

B. No changes C. 09-02-2021 – 1. Page 2.1a updated Titan AMU, 2.2 updated GH exhaust fan submittal.

Components:

2.1 AMU

2.1a AMU Drawing

2.2 Exhaust Fans

2.3 Light Study

2.3a Light Study – LED Strip – Cost Adder Alternate to 2.3

2.4 Exhaust Filters

2.5 Supply Filters

2.6 Caulking

2.7 Air Solenoid Valve

2.8 N/A

2.9 Door Switch

2.10 Manometer

2.11 N/A

2.12 N/A

2.13 N/A

2.14 N/A

2.15 N/A

2.16 N/A

2.17 N/A

2.18 N/A

2.19 N/A

2.20 N/A

2.21 N/A

Any Job Specific Components:

2.50 N/A

2.51 N/A

2.52 N/A

2.53 N/A

2.54 N/A

2.55 N/A

2.56 N/A

2.57 N/A

2.58 N/A

2.59 N/A

2.60 N/A

ACCESSORY

SIZE

OPTIONAL SLIDE IN

FILTER SECTION

94 75

ACCESS

BLOWER/

MOTOR

ACCESS

40x40x1

ELEC./

GAS TRAIN

ACCESS

40x55x1

FILTER

ACCESS

NTS

(FRONT)

SERVICE ELEVATION

NTS

(BACK)

FILTER ACCESS ELEVATION

NTS

RIGHT ELEVATION

NOTES:

- ACCESSORIES ARE LARGER THAN OPENINGS & SUPPORTED BY OTHERS

- MUST SHIP DROP DECK

VESTIBULE

VENT

POWER ENTRY LOCATION

(BOTH SIDES)

(OPTIONAL)

POWER ENTRY LOCATION

(THROUGH FLOOR)

(OPTIONAL)

15) 24x24xLP

GAS INLET

ACCESSORY

SIZE

QUOTE NUMBER:

SERIAL NUMBER:

NOTICE:

REP. NAME:

JOB NAME:DRAWING NAME:

DESCRIPTION:

DRAWN BY:

DRAWN DATE:

SHEET #:

ISSUE #:

SCALE:

REVIEWED:

CONFIDENTIAL PROPERTY OF TITAN AIR

LLLP. INFORMATION CONTAINED

ON THIS DRAWING IS CONFIDENTIAL IN

NATURE, IT MAY NOT BE REPRODUCED OR

RELEASED WITHOUT PRIOR WRITTEN

CONSENT OF TITAN AIR INCORPORATED.

W LARSON

TA-127 VRH

18590

19042-4

ROHNER

R20210008

8/13/2021

NTS 1-OF-1

x x

D I S

C H

A R

G E

D A

M P

E R

MOUNT AT

INSIDE WALL

D U

C T

B

Y

O

T H

E R

S

44 x 44

BY:____________________DATE:_____________

APPROVED/NO CHANGES ____

NOTE: THIS DRAWING IS PRELIMINARY UNTIL

APPROVED AND ACKNOWLEDGED BY TITAN AIR.

APPROVED WITH CHANGES ____

NOT APPROVED ____

APPROVAL PRINT

Performance Quantity 1

Volume (CFM) 22,000 Total External SP (in. wg) 0.5

Operating Power (hp) 5.2 Required Power (hp) 5.2

Fan RPM 1037 Max Fan RPM 1327

Elevation (ft) 26 Start-up Temp.(F) 70

Operating Temp.(F) 70

Fan Configuration Size 42

Arrangement 9 Level 3

Discharge Position Upblast Mounting Base Mount

Material Type Steel Spark Resistance None Impeller Material Aluminum

Equipment Weights Fan (LMD)(lb) 345

Motor/Drive (lb) 156 Accessories (lb) 85

Misc Fan Data Fan Eff. Index (FEI) 1.29

Outlet Velocity (ft/min) 2,233 Static Efficiency (%) 35

Tip Speed (ft/min) 11,407

Motor and Drives Motor Included

Size (hp) 7 1/2

RPM 1725

Enclosure TEFC V/C/P 460/60/3

Frame Size 213T Max Frame Size 215

Pulley Type Constant Drive Loss (%) 3.9

Drives Standard Drive Service Factor 1.5

NEC FLA* (Amps) 11

Model: TBI-CA-3H42-75 Tube Axial Belt Drive

Operating Performance

Sound Power by Octave Band Sound Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA

Inlet 106 100 95 93 88 84 80 77 95 83 *FLA - based on tables 150 or 148 of National Electrical Code 2002. Actual motor FLA may vary, for sizing thermal overload, consult factory.

LwA - A weighted sound power level, based on ANSI S1.4 dBA - A weighted sound pressure level, based on 11.5 dB attenuation per octave band at 5 ft- dBA levels are not licensed by AMCA International

08/30/2021Printed Date:

R20210008 - Exhaust FanJob:

TBI-22000-0.5-7.5Mark:

TBI-CA-3H42-75Model:

Generated by: kevinhsei@rohner-usa.comCAPS 4.36.1095 Page 1 of 3

R:\shared\CUSTOMER DOC\2021\S - Z\R20210008,SILER,Camp Lejune Marine Corps Base,MCD MAU\Vendor-Subcontractor Info,Bids,POs\GH \R20210008 - Exhaust Fan.gfcj

Model: TBI-CA-3H42-75 Tube Axial Belt Drive

Standard Construction Features:

HOUSING: Continuously welded housing - Inlet and Outlet flanges with mounting holes - Adjustable motor base - Extended lube lines with grease fittings

BEARINGS, SHAFT AND PROPELLER: Heavy duty, self aligning pillow block bearings - Turned, precision ground and polished shaft - Airfoil blade design - Cast aluminum propeller

Selected Options & Accessories:

Motor PN - 304933, Baldor Motor Model Number - EM3710T NEMA Premium Efficient Motor - meets NEMA Table 12-12 Motor VFD Rated without Shaft Grounding Protection Motor with Class B or Greater Insulation Standard Drives Coating - Permatector, Concrete Gray-RAL 7023, Fan and Attached Accessories UL/cUL-705 - "Power Ventilators" Mounting Support - Universal Belt Guard Mounting Rails Unit Warranty: 1 Yr (Standard)

08/30/2021Printed Date:

R20210008 - Exhaust FanJob:

TBI-22000-0.5-7.5Mark:

TBI-CA-3H42-75Model:

Generated by: kevinhsei@rohner-usa.comCAPS 4.36.1095 Page 2 of 3

R:\shared\CUSTOMER DOC\2021\S - Z\R20210008,SILER,Camp Lejune Marine Corps Base,MCD MAU\Vendor-Subcontractor Info,Bids,POs\GH

Bolt Circle Ø 44.25 Flange Hole Ø 0.56 Quantity 8

TOP VIEW

0.56 DIA. MOUNTING HOLES

TOP VIEW SHOWS FROM OUTLET END OF UNIT

A

IR

FL

O W

SIDE VIEW

37.25

MAX

17.38

50.00

51.25

42.50

45.75

30.00

Model: TBI-CA-3H42-75 Tube Axial Belt Drive

Notes: All dimensions shown are in units of in.

08/30/2021Printed Date:

R20210008 - Exhaust FanJob:

TBI-22000-0.5-7.5Mark:

TBI-CA-3H42-75Model:

Generated by: kevinhsei@rohner-usa.comCAPS 4.36.1095 Page 3 of 3

R:\shared\CUSTOMER DOC\2021\S - Z\R20210008,SILER,Camp Lejune Marine Corps Base,MCD MAU\Vendor-Subcontractor Info,Bids,POs\GH

Date:5/17/2021 Page 1 of 2

The placement of any windows, doors, ductwork, etc. not shown was not factored in the calculation results. Such areas may have a negative effect on the results. Also not included is the presence of the object(s) being painted, prepped, etc., which will affect the Actual

Foot Candle, reading at that area. Calculation is also performed assuming a clean maintenance factor and the effects of dirt and/or dust, etc.

are absent.

The factors above may reduce Light Values by up to 20%.

The numeric values represent the Initial Foot Candle reading at the calculation plane(s).

If you should have any questions or comments regarding the calculations given, please do not hesitate to contact LDPI Lighting, Inc.

at anytime. Normal business hours are from 8:00 AM thru 4:30 PM, Central Time, Monday thru Thursday and 7:30 AM thru 4:00 PM, Central

Time on Friday.

Copyright© 2019 by LDPI, Inc. All rights reserved.

LDPI, Inc.

4404 Anderson Drive

Eau Claire, WI 54703-3607

Tel. (800) 854-0021 Or (715) 839-9585

Fax. (715) 839-8145

E-Mail. Sales@ldpi-inc.com.

ROHNER - R202100008

45 X 24 X 10 FT

Walls - .7, Ceiling - .2 (Filter), Floor - .3

Room Summary

Summary

Special Notes or Features Surface Reflectances

Area WP CalcType Units Avg Max Min

Room_1_Workplane 3 Illuminanc Fc

Luminaire Schedule

Symbol Label LLF Qty Watts

107 166 31

Lumens

390440-LEDS5 0.950 22 68 6150

Date:5/17/2021 Page 2 of 2

Copyright© 2019 by LDPI, Inc. All rights reserved.

LDPI, Inc.

4404 Anderson Drive

Eau Claire, WI 54703-3607

Tel. (800) 854-0021 Or (715) 839-9585

Fax. (715) 839-8145

E-Mail. Sales@ldpi-inc.com.

ROHNER - R202100008

45 X 24 X 10 FT

31 39 48 56 65 74 84 92 96 95 89 80 70 61 53 46 38 31

37 49 61 72 82 93 105 114 118 117 110 100 89 78 68 57 46 36

46 65 82 96 108 118 127 135 138 137 132 124 114 103 90 75 58 44

55 79 102 118 130 139 146 150 153 152 149 144 136 125 110 92 70 51

61 89 114 132 144 151 157 160 162 161 159 156 150 140 124 103 78 57

65 94 121 139 150 158 162 164 165 166 164 161 156 147 131 109 83 61

66 96 123 141 152 159 162 164 164 165 164 161 157 148 133 111 85 62

66 95 122 139 149 154 157 157 157 158 158 157 154 146 132 111 84 62

64 92 117 133 142 145 144 144 143 143 145 146 145 139 127 107 82 60

60 84 107 122 128 128 125 121 119 120 124 127 130 127 117 99 76 56

53 74 93 105 110 108 102 96 93 94 99 106 110 110 102 87 67 50

46 62 76 85 89 87 82 77 74 75 79 85 89 89 83 72 57 44

1-800-854-0021 www.ldpi-inc.com LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc.

Product design and specifications subject to change without notice.

Visit www.ldpi-inc.com for the most current version and photometric data. v.02.05.21

SLIM LIGHT LED

Paint and Powder Booths ● Blast Booths ● Inspection ● Prep ● Sanding

LED HAZARDOUS BOOTH LIGHTING

1 2 3

The Slim Light LED Series features a 20 Ga. white powder coat steel housing that is only 2 ¼” thick. The Slim LED Series is available as a 4’ fixture with 2, 4 and 6 row LED tube options. It can be built with low and standard output factor drivers and is available with 5,000K LEDs. This series provides a hinged front door lens assembly with a paint spray cutoff switch when opened. This fixture must be installed with the hinge side up when being horizontally mounted. LED tubes and 8 Ft. wire whip included. Contact LDPI for availability.

CERTIFICATIONS

UL844 / CSA-C22.2 No.137 (Hazardous) CI D2, Grps A,B,C,D CII D2, Grps F,G Paint Spray Listed T-Codes: CI D2, CII D2=T3C UL1598 / CSA-C22.2 No.250 (Wet/Damp) Lumen Maintenance (L70) >50,000 hrs. (lamps only)

CRI >80

-18°C to 40°C Ambient

CONSTRUCTION

20 gauge white powder coated steel housing Hinged front access panel 4Ft. Length (nominal dimension) Access panel clear tempered glass 1/2” NPT Hubs Weight: Min: 34lbs. / Max: 52lbs.

ELECTRICAL

120-277VAC

8Ft. 5-Wire whip standard, factory installed

FEATURES

2.25” depth 40%+ energy savings compared to F32 T8 fluorescent lamps Recess mount, front access 5 Year Warranty

PERFORMANCE

1 SERIES 2 SOURCE 3 CCT

420: 2 Row 440: 4 Row 460: 6 Row

L: Low Output Factor* S: Standard Output Factor H: High Output Factor

*only available with 390440-LED (4 Row)

5: 5,000K

390 -LED 5

SERIES Source Voltage (VAC)

50/60Hz Input Current

(A) Wattage

(W) Lumen Output* (Lm)

5,000K

390420-LED

L

120-277 n/a S .29 - .13 35 3250 H .41 - .18 49 4010

390440-LED

L .54 - .23 64 5470 S .59 - .26 70 6150 H .82 - .35 97 8550

390460-LED

L n/a S .88 - .38 105 10070 H 1.22 - .53 145 13310

* Nominal values

Kevin.Hsei Highlight

Kevin.Hsei Highlight

1-800-854-0021 www.ldpi-inc.com LDPI® is a registered trademark of LDPI, Inc. © LDPI, Inc.

Product design and specifications subject to change without notice.

Visit www.ldpi-inc.com for the most current version and photometric data. v.02.05.21

SLIM LIGHT LED

LED HAZARDOUS BOOTH LIGHTING

DIMENSIONS

Paint and Powder Booths ● Blast Booths ● Inspection ● Prep ● Sanding

PANEL CUTOUT DIMENSIONS

Model Dimensions* (in./mm)

C D

390420-LED 10.75" / 273 7.0" / 178

390440-LED 15.75” / 400 12.0" / 305

390460-LED 20.75” / 527 17.0" / 432

* Actual dimensions

C D

50.25" (1276.4mm)

16.0" (406mm)

16.0" (406mm)

16.0" (406mm)

.50" (12.7mm)

TYP.

.31" (7.9mm)

TYP.

.31" (7.9mm)

(12) PLCS

SYMMETRICAL

ABOUT CL

*NOTE

Normally open magnetic switches are intended to be used to trigger a relay (furnished by others) which disables the paint system. Because of the small capacity of the switch a solid state relay is recommended. It may be desired by others to utilize a separate power supply to segregate the relay (furnished by others) from the lighting power supply. The magnetic switch IS NOT designed to directly control light operation! The magnetic switch is rated for 10 watts resistive at a maximum of 300 VAC.

CAUTION

Overloading the switch circuits WILL cause failure. LDPI, Inc. recommends having a certified electrician/engineer review loads to ensure that overloading of switch does not occur.

SEE NOTE*

51.9" (1318mm)

1/2" NPT HUB

(BOTH ENDS)

50.0" (1270mm)

A B

2.25" (57.1mm)

Model Dimensions* (in./mm)

A B

390420-LED 9.5" / 241 13.0" / 330

390440-LED 14.50" / 368 18.0" / 457

390460-LED 19.50" / 495 23.0" / 584

* Nominal dimensions

Kevin.Hsei Highlight

Koch Filter Corporation Filtration Products Crafted with Pride

Maxi-Grid™

A Complete Line of Internally-Supported Panel Filters

• Self sealing design

• Progressive density media

• Durable steel internal support wire

• Individual panels or link panels for front access holding frames or side-access housings

• Excellent filter for high moisture applications

Bulletin No. K-902

Koch Filter Corporation offers six unique Maxi-Grid Panel Filters for use as prefilters or final filters in commercial and industrial air filtration systems of all types. Koch MG Panels are widely used in commercial office buildings, hospitals, paint spray booths, universities, and in many manufacturing facilities.

Maxi-Grid A Complete Line of Internally-Supported Panel filters

General Description and Primary Application(s)

Primary Feature

Physical Description (upstream /downstream)

Steel wire support

MERV Rating (According to ASHRAE 52.2)

Initial Pressure Drop

Dust Holding Capacity (According to ASHRAE 52.1)

Arrestance Efficiency (According to ASHRAE 52.1)

UL Classification

Tackifier (non-migrating)

Antimicrobial Treatment

Available in Links

MG200

Economical, 3-ply, UL Class 1 panel filter. For use in commercial buildings, hospitals, industrial plants, and paint spray booths.

UL Class 1;

cost-effective 3-ply

White / Green

Rust resistant, 9-gauge internal steel wire support

MERV 7

.36" w.g. @ 400 FPM

243 grams @ 1.5" w.g.

89.76%

UL Class 1

Downstream

No

Yes

MG300

All-purpose 3-ply panel filter.

For use in commercial buildings, hospitals and industrial plants.

Excellent replacement for standard and high capacity pleated filters. Ideal for high moisture applications.

White / Pink

Rust resistant, 9-gauge internal steel wire support

MERV 8

.28" w.g. @ 400 FPM

268 grams @ 1.5" w.g.

88.79%

UL Class 2

Encapsulated between 2nd and 3rd layers

No

Yes

MG400

Heavy-duty 4-ply panel designed for applications requiring higher efficiency. For use in commercial buildings, hospitals, industrial plants, and paint spray booths.

MERV 11,

antimicrobial-treated, 4-ply panel.

White / Green

Rust resistant, 9-gauge internal steel wire support

MERV 11

.48" w.g. @ 400 FPM

195 grams @ 1.5" w.g.

92.53%

UL Class 2

Downstream

Yes

Yes

General Description and Primary Application(s)

Primary Feature

Physical Description (upstream /downstream)

Steel wire support

MERV Rating (According to ASHRAE 52.2)

Initial Pressure Drop

Dust Holding Capacity (According to ASHRAE 52.1)

Arrestance Efficiency (According to ASHRAE 52.1)

UL Classification

Tackifier (non-migrating)

Antimicrobial Treatment

Available in Links

MG600

Externally supported diffusion panel filter designed for crossdraft and downdraft paint spray booths, automotive plants, and coating applications.

Combination air filter and diffusor panel for industrial paint spray booths.

White / White (air exit marked)

Rust resistant, 9-gauge external steel wire

N/A

.21" w.g. @ 100 FPM

117 grams @ 1.5" w.g.

96%

UL Class 2

Individual fibers are tackified

No

Yes

Slip-On Sleeves

Available in two versions, Type SS (polyester and spunbonded) and Type DL (dual-layered polyester).

Both feature replaceable wire frames. For use in fan coil units, package air conditioning units in hotels, commercial buildings, and hospitals.

Economical replacement for fiberglass filters.

Individual sleeves or sleeve rolls.

White / White

Replaceable, rust resistant, 9-gauge internal steel wire

MERV 5

Type SS: .30" w.g./Type DL: .34" w.g. @ 400 FPM

Type SS: 105 grams/Type DL: 140 grams @ 1.5" w.g.

85%

UL Class 2

No tackifier

No

No

MG550

3-ply all-white antimicrobial tackified panel with heavy duty wire support. For use in commercial buildings, hospitals, industrial plants, and paint spray booths.

Antimicrobial-treated, all-white “non-glare” panel.

White / White (air exit marked)

Rust resistant, 9-gauge internal steel wire support

MERV 8

.33" w.g. @ 400 FPM

245 grams @ 1.5" w.g.

89.67%

UL Class 2

Downstream

Yes

Yes

Koch Filter Corporation offers six unique Maxi-Grid Panel Filters for use as prefilters or final filters in commercial and industrial air filtration systems of all types. Koch MG Panels are widely used in commercial office buildings, hospitals, paint spray booths, universities, and in many manufacturing facilities.

Maxi-Grid A Complete Line of Internally-Supported Panel filters designer2

Maxi-Grid Technical Data and Performance Specifications Nominal Actual Wire Capacity (CFM) Resistance (in W.G.)

Size Size Low/Med/High MG 200 MG 300 MG 400 MG 550 MG 600

300 400 500 FPM 300 400 500 FPM 300 400 500 FPM 300 400 500 FPM 300 400 500 FPM 300 400 500 FPM

10x20" 91⁄2 x 191⁄2" 417/556/694 .24/.36/.49 .19/.28/.38 .34/.48/.67 .25/.33/.41 .91/1.38/1.92

12x24 111⁄2 x 231⁄2 600/800/1000 .24/.36/.49 .19/.28/.38 .34/.48/.67 .25/.33/.41 .91/1.38/1.92

16x20 151⁄2 x 191⁄2 667/889/1111 .24/.36/.49 .19/.28/.38 .34/.48/.67 .25/.33/.41 .91/1.38/1.92

16x25 151⁄2 x 241⁄2 833/1111/1389 .24/.36/.49 .19/.28/.38 .34/.48/.67 .25/.33/.41 .91/1.38/1.92

20x20 191⁄2 x 191⁄2 833/1111/1389 .24/.36/.49 .19/.28/.38 .34/.48/.67 .25/.33/.41 .91/1.38/1.92

20x24 191⁄2 x 231⁄2 1000/1333/1667 .24/.36/.49 .19/.28/.38 .34/.48/.67 .25/.33/.41 .91/1.38/1.92

20x25 191⁄2 x 241⁄2 1050/1388/1736 .24/.36/.49 .19/.28/.38 .34/.48/.67 .25/.33/.41 .91/1.38/1.92

24x24 231⁄2 x 231⁄2 1200/1600/2000 .24/.36/.49 .19/.28/.38 .34/.48/.67 .25/.33/.41 .91/1.38/1.92

Particle Fractional Efficiency

Ef fic ie nc y

Particle Size (Microns)

1 2 3 4 5 6 7 8 9 10

MG550

MG400

MG300

MG200

MG600

Airflow vs. Resistance

Airflow (CFM)

Re si st an ce in ch es W

.G

0.

0.

0.

0.

0.

500 1000 1500 2000 2500

Link Panels Koch Maxi-Grid Panels are also available linked in a continuous series of panels for installation into side access filter housings. MG Link Panels allow for quick and easy installation and removal of the filter from the channel as a single unit.

Link Panels eliminate the possibility of air bypass caused by gaps between filters or gaps at the end of a filter track.

designer2 Highlight designer2 Highlight designer2

SDS Number: 00010002001 Revision Date: 10/23/2018

Safety Data Sheet

24 Hour Emergency Phone Numbers Medical/Poison Control:

In U.S.: Call 1-800-222-1222

Outside U.S.: Call your local poison control center

Transportation/National Response Center:

1-800-535-5053 1-352-323-3500

NOTE: The National ResponseCenter emergency numbers to be used only in the event of chemical emergencies involving a spill, leak, fire, exposure or accident involving chemicals.

IMPORTANT: Provide this information to employees, customers, and users of this product. Read this SDS before handling or disposing of this product. This product is covered by the OSHA Hazard Communication Standard and this document has been prepared in accordance with requirements of this standard. All abbreviated terms used in this SDS are further described in Section 16.

1. Identification

This Safety Data Sheet is available in American Spanish upon request.

Los Datos de Serguridad pueden obtenerse en Espanol si lo riquiere.

Product Name: Alex Plus Acrylic Latex Caulk Plus Silicone - All Colors

Revision Date: 10/23/2018

9/12/2018Product UPC Number: 070798181106, 070798181120, 070798181113, 070798181090, 070798181076, 070798181359, 070798181014, 070798181281, 070798181366, 070798181724, 070798181557, 070798114401

Supercedes Date:

Product Use/Class: Caulking Compound SDS No: 00010002001

Preparer:Manufacturer: DAP Products Inc.

2400 Boston Street Suite 200 Baltimore, MD 21224-4723 888-327-8477 (non - emergency matters)

SDS Coordinator: MSDS@dap.com

Emergency Telephone:

Transportation: 1-800-535 -5053 1-352-323-3500 Poison Control: 1-800-222-1222

Regulatory and Environmental Affairs

2. Hazards Identification

Page 1 / 6

GHS Classification Not a hazardous substance or mixture.

Symbol(s) of Product

None

Signal Word Not a hazardous substance or mixture.

Possible Hazards 6% of the mixture consists of ingredients of unknown acute toxicity

3. Composition/Information on Ingredients

Chemical Name CAS-No. Wt. % GHS Symbols GHS Statements Limestone 1317-65-3 45-70 No Information No Information Lubricating petroleum oil 72623-86-0 3-7 GHS07 H332 Petroleum distillates 64741-88-4 1-5 GHS06 H331 Dipropylene glycol dibenzoate 27138-31-4 1-5 No Information No Information Solvent ref. light paraffinic 64741-89-5 0.5-1.5 GHS06 H331 Diethylene glycol dibenzoate 120-55-8 0.5-1.5 GHS07 H312 Titanium dioxide 13463-67-7 0.1-1.0 No Information No Information Quartz 14808-60-7 0.1-1.0 GHS07 H302 Carbon black 1333-86-4 0.1-1.0 GHS02 H251

The text for GHS Hazard Statements shown above (if any) is given in the "Other information" Section.

4. First-aid Measures

FIRST AID - INHALATION: Material is not likely to present an inhalation hazard at ambient conditions. If you experience difficulty in breathing, leave the area to obtain fresh air. If continued difficulty is experienced, get medical attention immediately.

FIRST AID - SKIN CONTACT: In case of contact, wash skin immediately with soap and water.

FIRST AID - EYE CONTACT: In case of contact, immediately flush eyes with large quantities of water for at least 15 minutes until irritation subsides. Get medical attention immediately.

FIRST AID - INGESTION: If swallowed, DO NOT INDUCE VOMITING. Get medical attention immediately.

5. Fire-fighting Measures

UNUSUAL FIRE AND EXPLOSION HAZARDS: No Information

SPECIAL FIREFIGHTING PROCEDURES: Wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent) and full protective gear. Use water spray to cool exposed surfaces.

EXTINGUISHING MEDIA: Alcohol Foam, Carbon Dioxide, Dry Chemical, Foam, Water Fog

6. Accidental Release Measures

ENVIRONMENTAL MEASURES: No Information

STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED: Use personal protective equipment as necessary. In case of spillage, absorb with inert material and dispose of in accordance with applicable regulations. Scrape up dried material and place into containers.

7. Handling and Storage

HANDLING: KEEP OUT OF REACH OF CHILDREN!DO NOT TAKE INTERNALLY. Use only with adequate ventilation. Ensure fresh air entry during application and drying. Wash thoroughly after handling.

STORAGE: Avoid excessive heat and freezing. Do not store at temperatures above 120 degrees F. Store away from caustics and oxidizers.

8. Exposure Controls/Personal Protection

Ingredients with Occupational Exposure Limits Chemical Name ACGIH TLV-TWA ACGIH-TLV STEL OSHA PEL-TWA OSHA PEL-CEILING

Page 2 / 6

Limestone N.E. N.E. 15 mg/m3 TWA total dust, 5 mg/m3 TWA respirable fraction

N.E.

Lubricating petroleum oil N.E. N.E. N.E. N.E.

Petroleum distillates N.E. N.E. N.E. N.E.

Dipropylene glycol dibenzoate N.E. N.E. N.E. N.E.

Solvent ref. light paraffinic N.E. N.E. N.E. N.E.

Diethylene glycol dibenzoate N.E. N.E. N.E. N.E.

Titanium dioxide 10 mg/m3 TWA N.E. 15 mg/m3 TWA total dust N.E.

Quartz 0.025 mg/m3 TWA respirable particulate matter

N.E. 50 µg/m3 TWA N.E.

Carbon black 3 mg/m3 TWA inhalable particulate matter

N.E. 3.5 mg/m3 TWA N.E.

Further Advice: MEL = Maximum Exposure Limit OES = Occupational Exposure Standard SUP = Supplier's Recommendation Sk = Skin Sensitizer N.E. = Not Established

Personal Protection

RESPIRATORY PROTECTION: No personal respiratory protective equipment normally required. National Institute for Occupational Safety and Health (NIOSH) has recommended that the permissible exposure limit be changed to 50 micrograms respirable free silica per cubic meter of air (0.05 mg/m3) as determined by a full shift sample up to 10-hour work shift.

SKIN PROTECTION: Rubber gloves.

EYE PROTECTION: Goggles or safety glasses with side shields.

OTHER PROTECTIVE EQUIPMENT: Not required under normal use.

HYGIENIC PRACTICES: Wash hands before breaks and at the end of workday. Remove and wash contaminated clothing before re-use.

9. Physical and Chemical Properties

Appearance: Colored Physical State: Paste Odor: Very Slight Ammonia Odor Threshold: Not Established Density, g/cm3: 1.60 - 1.67 pH: Between 7.0 and 12.0 Freeze Point, °C: Not Established Viscosity (mPa.s): Not Established Solubility in Water: No Information Partition Coeff., n-octanol/water: Not Established Decomposition Temperature, °C: Not Established Explosive Limits, %: N.E. - N.E.

Boiling Range, °C: 100 - 100 Auto-Ignition Temperature, °C Not Established Minimum Flash Point, °C: 100 Vapor Pressure, mmHg: Not Established Evaporation Rate: Slower Than n-Butyl Acetate Flash Method: Seta Closed Cup Vapor Density: Heavier Than Air Flammability, NFPA: Non-Flammable Combustibility: Does not support combustion

(See "Other information" Section for abbreviation legend) (If product is an aerosol, the flash point stated above is that of the propellant.)

Page 3 / 6

10. Stability and Reactivity

STABILITY: Stable under recommended storage conditions.

CONDITIONS TO AVOID: Excessive heat and freezing.

INCOMPATIBILITY: Incompatible with strong bases and oxidizing agents.

HAZARDOUS DECOMPOSITION PRODUCTS: Normal decomposition products, i.e., COx, NOx.

11. Toxicological Information

EFFECT OF OVEREXPOSURE - INHALATION: Under normal use conditions, this product is not expected to cause adverse health effects. Inhalation of vapors in high concentration may cause mild irritation of respiratory system (nose, mouth, mucous membranes).

EFFECT OF OVEREXPOSURE - SKIN CONTACT: Under normal use conditions, this product is not expected to cause adverse health effects. Prolonged or repeated contact with skin may cause mild irritation.

EFFECT OF OVEREXPOSURE - EYE CONTACT: Under normal use conditions, this product is not expected to cause adverse health effects. Direct eye contact may cause irritation.

EFFECT OF OVEREXPOSURE - INGESTION: Under normal use conditions, this product is not expected to cause adverse health effects. Single dose oral toxicity is very low. Amounts ingested incidental to industrial handling are not likely to cause injury; however, ingestion of large amounts may cause injury.

CARCINOGENICITY: No Information

EFFECT OF OVEREXPOSURE - CHRONIC HAZARDS: Repeated or prolonged exposure may cause mild irritation of eyes and skin. The International Agency for Research on Cancer (IARC) has determined that crystalline silica in the form of quartz or cristobalite that is inhaled from occupational sources is carcinogenic to humans (Group 1- carcinogenic to humans). Refer to IARC Monograph 68, Silica, Some Silicates and Organic Fibres (published in June 1997) in conjunction with the use of these materials. The National Toxicology Program (NTP) classifies respirable crystalline silica as "known to be a human carcinogen". Refer to the 9th Report on Carcinogens (2000). The American Conference of Governmental Industrial Hygienists (ACGIH) classifies crystalline silica, quartz, as a suspected human carcinogen (Group A2). Breathing dust containing respirable crystalline silica may not cause noticeable injury or illness even though permanent lung damage may be occurring. Inhalation of dust may have the following serious chronic health effects: Excessive inhalation of respirable dust can cause pneumoconiosis, a respiratory disease, which can result in delayed, progressive, disabling and sometimes fatal lung injury. Symptoms include cough, shortness of breath, wheezing, non-specific chest illness and reduced pulmonary function. Smoking exacerbates this disease. Individuals with pneumoconiosis are predisposed to develop tuberculosis. There is some evidence that breathing respirable crystalline silica or the disease silicosis is associated with an increased incidence of significant disease endpoints such as scleroderma (an immune system disorder manifested by fibrosis of the lungs, skin and other internal organs) and kidney disease.

PRIMARY ROUTE(S) OF ENTRY: Skin Contact, Inhalation

Acute Toxicity Values The acute effects of this product have not been tested. Data on individual components are tabulated below

CAS-No. Chemical Name Oral LD50 Dermal LD50 Vapor LC50 1317-65-3 Limestone 6450 mg/kg Rat >2000 mg/kg >20 mg/L

72623-86-0 Lubricating petroleum oil >5000 mg/kg Rat >2000 mg/kg Rabbit N.I.

64741-88-4 Petroleum distillates >5000 mg/kg Rat >2000 mg/kg Rabbit 2.18 mg/L Rat

27138-31-4 Dipropylene glycol dibenzoate 5368 mg/kg Rat >2000 mg/kg Rabbit >200 mg/L Rat

64741-89-5 Solvent ref. light paraffinic >15000 mg/kg Rat >5000 mg/kg Rabbit 2.18 mg/L Rat

120-55-8 Diethylene glycol dibenzoate 2830 mg/kg Rat 2000 mg/kg Rabbit >200 mg/L Rat

13463-67-7 Titanium dioxide >10000 mg/kg Rat >5000 mg/kg Rabbit >20 mg/L

14808-60-7 Quartz 500 mg/kg Rat >2000 mg/kg >20 mg/L

1333-86-4 Carbon black >15400 mg/kg Rat N.I. N.I.

N.I. = No Information

Page 4 / 6

12. Ecological Information

ECOLOGICAL INFORMATION: Ecological injuries are not known or expected under normal use.

13. Disposal Information

DISPOSAL INFORMATION: This product does not meet the definition of a hazardous waste according to U.S. EPA Hazardous Waste Management Regulation, 40 CFR Section 261. Dispose as hazardous waste according to all local, state, federal and provincial regulations. State and Local regulations/restrictions are complex and may differ from Federal regulations. Responsibility for proper waste disposal is with the owner of the waste.

14. Transport Information

SPECIAL TRANSPORT PRECAUTIONS: No Information

DOT UN/NA Number: N.A.

DOT Proper Shipping Name: Not Regulated DOT Technical Name: N.A.

DOT Hazard Class: N.A.

Hazard SubClass: N.A.

Packing Group: N.A.

15. Regulatory Information

SARA SECTION 313:

This product contains the following substances subject to the reporting requirements of Section 313 of Title III of the Superfund Amendment and Reauthorization Act of 1986 and 40 CFR part 372:

No Sara 313 components exist in this product.

TOXIC SUBSTANCES CONTROL ACT:

All ingredients in this product are either on TSCA inventory list, or otherwise exempt.

This product contains the following chemical substances subject to the reporting requirements of TSCA 12(B) if exported from the United States:

No TSCA 12(b) components exist in this product.

16. Other Information

Supersedes Date: 9/12/2018Revision Date: 10/23/2018 Reason for revision: Substance and/or Product Properties Changed in Section(s):

05 - Flammability Information 09 - Physical & Chemical Information 11 - Toxicological Information 13 - Disposal Information 14 - Transportation Information

Datasheet produced by: Regulatory Department HMIS Ratings:

Health: Flammability: Reactivity: Personal Protection:

1 1 0 X

VOC Less Water Less Exempt Solvent, g/L: 37.5 VOC Material, g/L: 27

0.8VOC as Defined by California Consumer Product Regulation, Wt/Wt%:

VOC Actual, Wt/Wt%: 1.6

Page 5 / 6

Text for GHS Hazard Statements shown in Section 3 describing each ingredient:

H251 Self-heating: may catch fire.

H302 Harmful if swallowed.

H312 Harmful in contact with skin.

H331 Toxic if inhaled.

H332 Harmful if inhaled.

Icons for GHS Pictograms shown in Section 3 describing each ingredient:

GHS02

GHS06

GHS07

Legend: N.A. - Not Applicable, N.E. - Not Established, N.D. - Not Determined

DAP believes the data and…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .