About this file

This document provides details for a federal solicitation to design and construct an F-35 Training and Simulator Facility at Marine Corps Air Station Cherry Point in North Carolina. The solicitation number is N40085-20-R-0015 and proposals are due on April 9, 2020 by 2:00pm EDT. The pre-proposal inquiry cut-off date is 10 days prior to the proposal due date. The magnitude of construction is estimated between $25 million to $100 million. The NAICS code is 236210 for industrial building construction and the small business size standard is $39.5 million. This acquisition will be conducted as full and open competition on an unrestricted basis. The wage determination general decision number is NC20200065 from January 3, 2020. The Department of the Navy, Naval Facilities Engineering Command is the issuing agency.

View the file

Other files

File Type Posted
Amendment 0009.pdf PDF
Amendment 8 P204 Drawings-Specs.pdf PDF
Amendment 0008.pdf PDF
Amendment 8 Attachment I -Updated Price Proposal Form_REVISED.pdf PDF
Amendment 0007-Update Proposal Submission.pdf PDF
Amendment 6 Attachment I-REVISED Price Proposal Form.pdf PDF
Amendment 0006.pdf PDF
Amendment 5.pdf PDF
Amendment 0005 PPI Responses.pdf PDF
Amendment 5 PPI-31_P-204 Soil Guidance Section for NEPA-PAMS.pdf PDF
Amendment 5 M-602.pdf PDF
Amendment 4 B286_Photos.zip ZIP file
Amendment 4 P204 B286 B4038 B4162 Existing FFE List Floor Plans.pdf PDF
Amendment 4 B4038_2of2.zip ZIP file
Amendment 0004.pdf PDF
Amendment 4-B286_As-Built Drawings.pdf PDF
Amendment 4 P204 FF E List for Contractors.xlsx XLSX spreadsheet
Amendment 4 B4038_1of2.zip ZIP file
Amendment 3-Attachment I - Price Proposal Form_REVISED.docx DOCX document
Amendment 3-P-204_Hazardous Survey.pdf PDF
Amendment 3-B4038_As-Built Drawings_01.pdf PDF
Amendment 3-P-204_Site Investigation Report.pdf PDF
Amendment 0003.pdf PDF
Amendment 3-B4038_As-Built Drawings_02.pdf PDF
Amendment 3-B4162_As-Built Drawings.pdf PDF
Amendment 0002 Extend Proposal Due Date.pdf PDF
Amendment 0001 Site Visit Cancelled.pdf PDF
Attachment I - Price Proposal Form.docx DOCX document
Attachment D - Small Business Subcontracting Record.docx DOCX document
Attachment F - Past Performance Questionnaire.docx DOCX document
1596300dwg17of26_Interiors.pdf PDF
Attachment E - Small Business Participation and Commitment Strategy.docx DOCX document
1596300dwg03of26_Civil-C.pdf PDF
1596300dwg24of26_Electrical.pdf PDF
1596300dwg11of26_Civil-CS.pdf PDF
1596300dwg25of26_Telecom-AV.pdf PDF
1596300dwg14of26_Structural.pdf PDF
1596300dwg26of26_Telecom.pdf PDF
Attachment B - SECNAV 5512.pdf PDF
1596300dwg20of26_Mechanical.pdf PDF
1596300spc02of04.pdf PDF
1596300dwg09of26_Civil-CG.pdf PDF
Attachment J - Site Visit Map to B-163.pdf PDF
1596300dwg16of26_Architectural.pdf PDF
Attachment A - Pre-Proposal Inquiries Form.xlsx XLSX spreadsheet
1596300dwg23of26_Electrical.pdf PDF
1596300dwg06of26_Civil-CE.pdf PDF
RFP- P204.pdf PDF
Attachment G - Small Business Subcontracting Plan.docx DOCX document
1596300dwg01of26_General.pdf PDF
Show 40 more

Latest 50 of 69 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amendment

To: Rosie Shanks

NAVFAC MIDATLANTIC

9324 Virginia Avenue

Bldg Z-144, 2nd Flr

Norfolk, VA 23551

Amendment: 003

Requested By: Burns & McDonnell

Date Issued: 04/07/2020

Subject: P-204 F-35 Simulator and Training Facility

Contract No.: N40085-18-D-0600

Specification Reference: See Below

Drawing Reference: See Below

Reason for Change: [ X ] Change in Scope [ ] Unforeseen Condition [ ] Error or Omission

Description of Scope Change:

This Amendment is an update to the contract drawings to reflect additional Owner direction, and/or changes in design as follows:

Document 00 01 15 List of Drawings

1.2 Contract Drawings

The following drawings are revised as of 04/06/2020:

NAVFAC Dwg. Nos.

12804039 S-113 – ROOF FRAMING PLAN – AREA C

12804040 S-114 – ROOF FRAMING PLAN – AREA D

These revised Drawings accompany this Amendment.

Document 00 01 15 List of Drawings

1.2 Contract Drawings

On NAVFAC Dwg No. 12804039 ROOF FRAMING PLAN – AREA C

Text note on plan between gridlines 18 and 19. Delete reference “RE: C1/S-313” and replace with “RE: A1/S-

312”.

On NAVFAC Dwg No. 12804040 ROOF FRAMING PLAN – AREA D

Text note on plan between gridlines 18 and 19. Delete references “RE: C1/S-313” and replace with “RE: A1/S-

312”.

SECTION 05 12 00 DOOR HARDWARE

2.6.2 Shop Primer

Delete first sentence and replace with the following: “SSPC Paint 20 or SSPC Paint 29, (zinc rich primer), for exposed exterior steel. Standard shop primer otherwise.”

SECTION 08 71 00 DOOR HARDWARE

3.6 HARDWARE SETS

Delete this section in its entirety and replace with the attached.

SECTION 09 90 00 PAINTS AND COATINGS

1.3.1 SSPC QP 1 Certification

Delete this paragraph in its entirety and replace with the following:

“1.3.1 Contractor Qualification

Submit the name, address, telephone number, FAX number, and e-mail address of the contractor that will be performing all surface preparation and coating application. Submit evidence that key personnel have successfully performed surface preparation and application of coatings on a minimum of three similar projects within the past three years. List information by individual and include the following:

a. Name of individual and proposed position for this work.

b. Information about each previous assignment including:

Position or responsibility

Employer (if other than the Contractor)

Name of facility owner

Mailing address, telephone number, and telex number (if non-US) of facility owner

Name of individual in facility owner's organization who can be contacted as a reference

Location, size and description of structure

Dates work was carried out

Description of work carried out on structure”

SECTION 31 21 13 VAPOR MITIGATION SYSTEM

2.1.2 Vapor Mitigation Systems Components

Replace “f. Crawl space soil-gas retarder membrane must be minimum 40 mils thick.”

With “f. Crawl space soil-gas retarder membrane must be minimum 20 mils thick.”

--End of Amendment--

P-204 F-35 Training and Simulator Facility

MCAS Cherry Point, North Carolina

Work Order Number 1590340

3.6 HARDWARE SETS

Manufacturer's Abbreviations:

1. MK - McKinney

2. PE - Pemko

3. RF - Rixson

4. RO - Rockwood

5. RW - Richards Wilcox

6. SA - SARGENT

7. YA - Yale

8. KA - Kaba Ilco

9. SU - Securitron

10. SI - Simplex-KABA ILCO

11. HS - HES

12. LK - Lockwood

13. NO - Norton

14. HD - HID

15. OT - OTHER

Hardware Sets

Set: 1.0

Doors: 101

Description: Exterior Aluminum Keypad Access Exit Pair

1 Hinge - A31041G CFMxxHD1 x Door Height PE

2 Exit Device - Type 4, F01 WS AD8510 US32D SA

1 Mechanical Pushbutton Lever Trim 5010-B WL 26D SI

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

2 Closer - C02021, PT4G (spring stop) CPS8501 689 NO

1 Threshold - J332133 x L A R 171A PE

2 Sweep - R3B434 x L A R 315CN x door width PE

Center mullion by door manufacturer for windstorm compliance.

Perimeter gasket by frame manufacturer.

Set: 2.0

Doors: 102B

Description: Aluminum Card Access Pair

2 Hinge - A31041G CFMxxHD1 x Door Height PE

2 Magnetic Lock - E08501-1000 x DPS x Bondstat M62BD SU

2 Push Bar & Pull - J505 BF15747 US32D RO

2 Closer - C02021, PT4G (spring stop) CPS8501 689 NO

1 Motion Sensor (by others) XMS (by others) SU

1 Wall Multiclass Reader SE RP40 (by others) HD

1 Emergency Exit Button - UL 294 EEB2 SU

1 Power Supply (by others) BPS-24 X Amperage as Required SU

Notes: Door position switch in magnetic lock indicates propped door condition.

Door controller and security management software by others.

Prep frame head for electronic device.

Perimeter gasket by frame manufacturer.

OPERATION: Card reader outside and motion sensor and emergency button inside temporarily unlock magnetic lock. Mag lock is fail-safe and includes integral door position switch sensor & status sensor.

Notes: OPERATION: Integral keypad outside temporarily unlocks outside lever when authorized PIN number is entered:

Automatic relock. Lock is mechanically operated with outside key override. Inside push bar always allows egress.

All exterior doors on this project shall meet prevailing local standards for windstorm. The door hardware specified is listed as a basis of design. If alternate hardware is proposed, please provide third-party test results and compliance information to architect.

Provide hardware for aluminum doors under this section. Deliver Hardware templates and hardware, except field-applied hardware, to the aluminum door and frame manufacturer for use in fabricating doors and frames.

SECTION 08 71 00

Work Order Number 1590340

Set: 3.0

Doors: 102A

Description: Aluminum Push-Pull Pair

2 Hinge - A31041G CFMxxHD1 x Door Height PE

2 Push Bar & Pull - J505 BF15747 US32D RO

2 Closer - C02021, PT4G (spring stop) CPS8501 689 NO

Notes: Perimeter gasket by frame manufacturer.

Set: 4.0

Doors: 112, 131, 147, 155, 163

Description: Exterior Exit-Only - STC Assembly

3 Hinge A5111 T4A3386 NRP 4-1/2" x 4-1/2" US32D MK

1 Exit Device Type 1, F01, Inside Alarm AL HC 72 8810 US32D SA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Closer - C02021, PT4G (spring stop) CPS8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Position Switch DPS-M-GY (by others) SU

Notes: Seals at frame perimeter and sill in lieu of scheduled silencers by STC door assembly manufacturer as indicated.

Door contact switch indicates propped door condition.

Set: 5.0

Doors: 104

Description: Exterior Exit-Only + Local Alarm

3 Hinge A5111 T4A3386 NRP 4-1/2" x 4-1/2" US32D MK

1 Exit Device Type 1, F01, Inside Alarm AL HC 72 8810 US32D SA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Closer - C02021, PT4G (spring stop) CPS8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Threshold - J332133 x L A R 171A PE

1 Gasketing x L A R 303CS head & jambs PE

1 Sweep - R3B434 x L A R 315CN x door width PE

Set: 6.0

Doors: 194

Description: Exterior Card Access Exit

3 Hinge A5111 T4A3386 NRP 4-1/2" x 4-1/2" US32D MK

1 Exit Device - Type 1, F03 - SFIC x Temp Core HC 72 8804 PSB US32D SA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Electric Strike - E09731, E09732, E09373 9600 630 HS

1 SMART Pac Bridge Rectifier 2005M3 HS

1 Closer - C02021, PT4G (spring stop) CPS8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Threshold - J332133 x L A R 171A PE

1 Gasketing x L A R 303CS head & jambs PE

1 Sweep - R3B434 x L A R 315CN x door width PE

1 Position Switch DPS-M-GY (by others) SU

1 Wall Multiclass Reader SE RP40 (by others) HD

1 Power Supply (by others) BPS-24 X Amperage as Required SU

All exterior doors on this project shall meet prevailing local standards for windstorm. The door hardware specified is listed as a basis of design. If alternate hardware is proposed, please provide third-party test results and compliance information to architect.

All exterior doors on this project shall meet prevailing local standards for windstorm. The door hardware specified is listed as a basis of design. If alternate hardware is proposed, please provide third-party test results and compliance information to architect.

Notes: OPERATION: Inside push bar is alarmed. Battery powered local alarm sounds when push bar is pressed. Key-cylinder in rail resets alarm.

Work Order Number 1590340

Notes: Access control panel and security management software by others.

Prep strike jamb for electrical component.

Door contact switch indicates propped door condition.

Set: 7.0

Doors: 228B, 229B, 230B

Description: Exterior Exit Only Pair - STC Assembly - NEC

6 Hinge A5111 T4A3386 NRP 4-1/2" x 4-1/2" US32D MK

1 Removable Mullion - Type 22 HC980 PC SA

2 Exit Device Type 1, F01, Inside Alarm AL HC 72 8810 US32D SA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

2 Closer - C02021, PT4G, PT8C (spring stop) CPS8501T 689 NO

2 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Threshold - J332133 x HWT x L A R 1715A PE

1 Gasketing x L A R 303CS head & jambs PE

2 Sweep - R3B434 x L A R 315CN x door width PE

2 Position Switch DPS-M-GY (by others) SU

Notes: Seals at frame perimeter and sill in lieu of scheduled silencers by STC door assembly manufacturer as indicated.

Refer to drawings and schedules for STC requirements.

Door contact switch indicates propped door condition.

If alternate hardware is proposed, please provide third-party test results and compliance information to architect.

OPERATION: Inside push bar is alarmed. Local alarm sounds when pressed. Key-cylinder in rail resets alarm.

Set: 8.0

Doors: 232, 234

Description: Exterior Electrical Room Storeroom Function Exit Pair

6 Hinge A5112 TA2314 NRP 4-1/2" x 4-1/2" US32D MK

1 Removable Mullion - Type 22 HC980 PC SA

1 Exit Device - Type 1, F03 - SFIC x Temp Core HC 72 8804 PSB US32D SA

1 Exit Device - Type 1, F01 HC 8810 US32D SA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

2 Closer - C02021, PT4G, PT8C (spring stop) CPS8501T 689 NO

1 Threshold - J332133 x HWT x L A R 1715A PE

1 Gasketing x L A R 303CS head & jambs PE

2 Sweep - R3B434 x L A R 315CN x door width PE

1 Mullion Gasket - R0C004 5110BL PE

2 Position Switch DPS-M-GY (by others) SU

Notes: Door contact switch indicates propped door condition.

If alternate hardware is proposed, please provide third-party test results and compliance information to architect.

Set: 9.0

Doors: 197A, 198A

Description: Classroom Function Exit

3 Hinge A8111 T4A3786 NRP 4-1/2" x 4-1/2" US26D MK

1 Fire Exit Hardware - Type 1, F08 - SFIC x Temp Core 12 72 8813 ETL US32D SA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Surface Closer - C02021 HDPA PR8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

All exterior doors on this project shall meet prevailing local standards for windstorm. The door hardware specified is listed as a basis of design.

All exterior doors on this project shall meet prevailing local standards for windstorm. The door hardware specified is listed as a basis of design.

OPERATION: Outside card reader temporarily unlocks electric strike: automatic relock. Electric strike is fail-secure.

Mechanical lock outside pull is always fixed. Outside key retracts latchbolt. Inside push bar always allows free egress.

All exterior doors on this project shall meet FBC standards for windstorm. The door hardware specified is listed as a basis of design. If alternate hardware is proposed, please provide third-party test results and compliance information to architect.

Work Order Number 1590340

Set: 10.0

Doors: 186A, 196A, 197B, 198B

Description: Exit-Only with Local Alarm

3 Hinge A8111 T4A3786 NRP 4-1/2" x 4-1/2" US26D MK

1 Exit Device Type 1, F01, Inside Alarm AL GL 72 8810 US32D SA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Surface Closer - C02021 HDPA PR8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

Notes: OPERATION: Inside push bar is alarmed. Local alarm sounds when pressed. Key-cylinder in rail resets alarm.

Set: 10.1

Doors: 190A

Description: Exit-Only with Local Alarm

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Exit Device Type 1, F01, Inside Alarm AL GL 72 8810 US32D SA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Closer - C02011 8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

Notes: OPERATION: Inside push bar is alarmed. Local alarm sounds when pressed. Key-cylinder in rail resets alarm.

Set: 11.0

Doors: 129

Description: Card Access Electrical Room Exit

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Rim Exit Device - Milled OS Lever 72 76 8804 ETL US32D SA

1 Electric Strike - E09731, E09732, E09373 9600 630 HS

1 SMART Pac Bridge Rectifier 2005M3 HS

1 Closer - C02021, PT4G (spring stop) CPS8501 689 NO

1 Gasketing - R3D166 x L A R S88D PE

1 Position Switch DPS-M-GY (by others) SU

1 Wall Multiclass Reader SE RP40 (by others) HD

1 Power Supply (by others) BPS-24 X Amperage as Required SU

Notes: Door contact switch indicates propped door condition.

Access control panel and security management software by others.

Prep strike jamb for electrical component.

Set: 11.1

Doors: 119A

Description: Card Access Exit - STC Assembly

3 Hinge A8111 T4A3786 NRP 4-1/2" x 4-1/2" US26D MK

1 Exit Device (classroom) 72 8813 ETL US32D SA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Electric Strike - E09731, E09732, E09373 9600 630 HS

1 SMART Pac Bridge Rectifier 2005M3 HS

1 Surface Closer - C02021 HDPA PR8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

1 ElectroLynx Harness (hinge to controller) QC-C1500P MK

1 ElectroLynx Harness QC-C306 MK

1 Position Switch DPS-M-GY (by others) SU

1 Wall Multiclass Reader SE RP40 (by others) HD

1 Power Supply (by others) BPS-24 X Amperage as Required SU

OPERATION: Outside card reader temporarily unlocks electric strike: automatic relock. Electric strike is fail-secure.

Mechanical lock outside lever is always fixed. Outside key retracts latchbolt. Inside lever is always free.

Work Order Number 1590340

Notes: Seals at frame perimeter and sill in lieu of scheduled silencers by STC door assembly manufacturer as indicated.

Refer to drawings and schedules for STC requirements.

Door contact switch indicates propped door condition.

Access control panel and security management software by others.

Prep strike jamb for electrical component.

Set: 12.0

Doors: 229A, 234B

Description: Electrical Room Exit - NEC

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Rim Exit Device - Milled OS Lever 72 76 8804 ETL US32D SA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Closer - C02021, PT4G (spring stop) CPS8501 689 NO

1 Gasketing - R3D166 x L A R S88D PE

Set: 13.0

Doors: 200, 203, 207

Description: Classroom Function

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F05 - SFIC Temp Core AUCN 8808FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

Set: 14.0

Doors: 187, 208A

Description: Classroom Function + Closer

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F05 - SFIC Temp Core AUCN 8808FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Closer - C02011 8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

Set: 15.0

Doors: 182

Description: Card Access Pair - Magnetic Lock + Closer

6 Hinge A8111 T4A3786 NRP 4-1/2" x 4-1/2" US26D MK

1 Dust Proof Strike L04021 570 US26D RO

2 Flush Bolt L04251 555 US26D RO

1 Lockset - Series 1000 - F05 - SFIC Temp Core AUCN 8808FL K625xCT6SL 630 YA

1 Magnetic Lock - E08501-1000 x DPS x Bondstat M62BD SU

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Closer - C02011 8501 689 NO

2 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

2 Wall Stop - L02101 406 US32D RO

1 Astragal - R5Y63 357SS x Door Height PE

2 Silencer - L03011 608 RO

1 Motion Sensor (by others) XMS (by others) SU

1 Emergency Exit Button - UL 294 EEB2 SU

Notes: Install magnetic lock & closer on active leaf.

Door controller and security management software by others.

OPERATION: Outside card reader temporarily unlocks electric strike: automatic relock. Electric strike is fail-secure.

Mechanical lock outside lever is always fixed. Outside key retracts latchbolt. Inside lever is always free.

OPERATION: Card reader outside and motion sensor inside or emergency button inside temporarily unlock magnetic lock. Mag lock is fail-safe and includes integral PIR/motion sensor & status sensor.

Work Order Number 1590340

Set: 16.0

Doors: 209, 216

Description: Classroom Function

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F05 - SFIC Temp Core AUCN 8808FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

Notes: Seals at frame perimeter and sill by STC door assembly manufacturer.

Refer to drawings and schedules for STC requirements.

Set: 17.0

Doors: 106B, 107, 111, 113, 125, 136, 143, 152, 160, 168, 172, 186B, 191

Description: Card Access - STC Assembly

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F04 - SFIC Temp Core AUCN 8807FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 SMART Pac Bridge Rectifier 2005M3 HS

1 Electric Strike - L2E06 1006 630 HS

1 Closer - C02011 8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

1 Position Switch DPS-M-GY (by others) SU

1 Wall Multiclass Reader SE RP40 (by others) HD

1 Power Supply (by others) BPS-24 X Amperage as Required SU

Notes: Seals at frame perimeter and sill in lieu of scheduled silencers by STC door assembly manufacturer as indicated.

Refer to drawings and schedules for STC requirements.

Access control panel and security management software by others.

Prep strike jamb for electrical component.

Door contact switch indicates propped door condition.

OPERATION: Outside card reader temporarily unlocks electric strike: automatic relock. Electric strike is fail-secure.

Mechanical lock outside lever is always fixed. Outside key retracts latchbolt. Inside lever is always free.

Set: 18.0

Doors: 130, 183

Description: Card Access

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F05 - SFIC Temp Core AUCN 8808FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 SMART Pac Bridge Rectifier 2005M3 HS

1 Electric Strike - L2E06 1006 630 HS

1 Overhead Stop - C02541 9-X36 630 RF

1 Closer - C02011 8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

3 Silencer - L03011 608 RO

1 Position Switch DPS-M-GY (by others) SU

1 Wall Multiclass Reader SE RP40 (by others) HD

1 Power Supply (by others) BPS-24 X Amperage as Required SU

Notes: Door contact switch indicates propped door condition.

Access control panel and security management software by others.

Prep strike jamb for electrical component.

OPERATION: Outside card reader temporarily unlocks electric strike: automatic relock. Electric strike is fail-secure.

Mechanical lock outside lever is always fixed. Outside key retracts latchbolt. Inside lever is always free.

Work Order Number 1590340

Set: 19.0

Doors: 106A, 185, 188

Description: Card + Combination Lock Access - STC Assembly

3 Hinge A8111 T4A3786 NRP 4-1/2" x 4-1/2" US26D MK

1 Combination Lock - FF-L-2890B, Type V CDX-10 x Strike as Required KA

1 Lockset - Series 1000 - F05 - SFIC Temp Core AUCN 8808FL K625xCT6SL 630 YA

1 Electric Strike - E09731, E09732, E09373 9600 630 HS

1 SMART Pac Bridge Rectifier 2005M3 HS

1 Electric Strike - L2E06 1006 630 HS

1 Surface Closer - C02021 HDPA PR8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

1 Position Switch DPS-M-GY (by others) SU

1 Wall Multiclass Reader SE RP40 (by others) HD

1 Power Supply (by others) BPS-24 X Amperage as Required SU

Notes: Seals at frame perimeter and sill in lieu of scheduled silencers by STC door assembly manufacturer as indicated.

Refer to drawings and schedules for STC requirements.

Access control panel and security management software by others.

Prep strike jamb for electrical component.

Door contact switch indicates propped door condition.

Set: 20.0

Doors: 115, 116, 117, 176, 177, 178, 179

Description: Card Access - STC Assembly

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F05 - SFIC Temp Core AUCN 8808FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 SMART Pac Bridge Rectifier 2005M3 HS

1 Electric Strike - L2E06 1006 630 HS

1 Closer - C02011 8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

1 Position Switch DPS-M-GY (by others) SU

1 Wall Multiclass Reader SE RP40 (by others) HD

1 Power Supply (by others) BPS-24 X Amperage as Required SU

Notes: Seals at frame perimeter and sill by STC door assembly manufacturer.

Refer to drawings and schedules for STC requirements.

Access control panel and security management software by others.

Prep strike jamb for electrical component.

Door contact switch indicates propped door condition.

OPERATION: Outside card reader temporarily unlocks electric strike: automatic relock. Electric strike is fail-secure.

Mechanical lock outside lever is always fixed. Outside key retracts latchbolt. Inside lever is always free.

Set: 21.0

Doors: 171A

Description: Card Access Pair - STC Assembly

5 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Hinge A8112 x 12-wire harness TA2714 QC12 4-1/2" x 4-1/2" US26D MK

1 Dust Proof Strike L04021 570 US26D RO

2 Flush Bolt L04251 555 US26D RO

1 Electric Lockset - Series 1000 U2-E01,E05 - SFIC AUCN 8891FL K625xCT6SL REX 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Closer - C02011 8501 689 NO

2 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

2 Wall Stop - L02101 406 US32D RO

1 ElectroLynx Harness (hinge to controller) QC-C1500P MK

1 ElectroLynx Harness QC-C306 MK

2 Position Switch DPS-M-GY (by others) SU

1 Wall Multiclass Reader SE RP40 (by others) HD

1 Power Supply (by others) BPS-24 X Amperage as Required SU

OPERATION: Door is normally locked by combination lock and storeroom lockset via electric strike. Unlock from outside by first unlocking combination lock. Card can then be presented at outside reader to retract electric strike, allowing ingress. Strike is fail-secure. Mechanical lever lock has outside key override. Egress requires retraction of combination lock by inside knob AND operation of inside lever to release latchbolt.

Work Order Number 1590340

Notes: Seals at frame perimeter and sill by STC door assembly manufacturer.

Install closer on active leaf.

Door contact switch indicates propped door condition.

Security management software and access control panel by others.

Prep door and hinge jamb for electronic lock.

Outside trim has key override. Inside trim always allows egress.

Set: 22.0

Doors: 121, 132, 139, 148, 156, 164

Description: Card Access - STC Assembly

3 Hinge A8111 T4A3786 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F05 - SFIC Temp Core AUCN 8808FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 SMART Pac Bridge Rectifier 2005M3 HS

1 Electric Strike - L2E06 1006 630 HS

1 Closer - C02011 8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

1 Position Switch DPS-M-GY (by others) SU

1 Wall Multiclass Reader SE RP40 (by others) HD

1 Power Supply (by others) BPS-24 X Amperage as Required SU

Notes: Seals at frame perimeter and sill in lieu of scheduled silencers by STC door assembly manufacturer as indicated.

Refer to drawings and schedules for STC requirements.

Access control panel and security management software by others.

Prep strike jamb for electrical component.

Door contact switch indicates propped door condition.

OPERATION: Outside card reader temporarily unlocks electric strike: automatic relock. Electric strike is fail-secure.

Mechanical lock outside lever is always fixed. Outside key retracts latchbolt. Inside lever is always free.

Set: 23.0

Doors: 114, 175, 196B

Description: Card Access + RX - STC Assembly

3 Hinge A8111 T4A3786 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F05 - SFIC Temp Core AUCN 8808FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 SMART Pac Bridge Rectifier 2005M3 HS

1 Electric Strike - L2E06 1006 630 HS

1 Closer - C02011 8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

1 Position Switch DPS-M-GY (by others) SU

1 Motion Sensor (by others) XMS (by others) SU

1 Wall Multiclass Reader SE RP40 (by others) HD

1 Power Supply (by others) BPS-24 X Amperage as Required SU

Notes: Seals at frame perimeter and sill in lieu of scheduled silencers by STC door assembly manufacturer as indicated.

Refer to drawings and schedules for STC requirements.

Access control panel and security management software by others.

Prep strike jamb for electrical component.

Door position is monitored by magnetic switch for authorized egress.

OPERATION: Outside card reader temporarily unlocks electric strike: automatic relock. Electric strike is fail-secure.

Mechanical lock outside lever is always fixed. Outside key retracts latchbolt. Inside lever is always free.

OPERATION: Card Reader outside temporarily unlocks outside lever: auto-relock. Electronic lock function is fail-secure with inside RX switch.

Work Order Number 1590340

Set: 24.0

Doors: 119B

Description: Exit Only + Alarm + Closer - STC Assembly

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Exit Device Type 1, F01, Inside Alarm AL GL 72 8810 US32D SA

1 Surface Closer - C02021 HDPA PR8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

1 Position Switch DPS-M-GY (by others) SU

Notes: Seals at frame perimeter and sill by STC door assembly manufacturer.

OPERATION: Inside push bar is alarmed. Local alarm sounds when pressed. Key-cylinder in rail resets alarm.

Door contact switch indicates propped door condition.

Set: 25.0

Doors: 127C, 138C, 145C, 154C, 162C, 170C

Description: Oversized Door Assembly - No Outside Access - STC Assembly

2 Cremone Bolt 1028-00320-012 RW

Notes: Seals at frame perimeter, meeting stile and sill by STC door assembly manufacturer.

Hinges by door assembly manufacturer.

Set: 26.0

Doors: 128, 171B

Description: Exterior Oversized Door Assembly - No Outside Access - STC Assembly

2 Cremone Bolt 1028-00320-012 RW

1 Padlock PD515 YA

2 Position Switch DPS-M-GY (by others) SU

1 Hasp 0182.00030ZC RW

Notes: Seals at frame perimeter, meeting stile and sill by STC door assembly manufacturer.

Hinges by door assembly manufacturer.

If alternate hardware is proposed, please provide third-party test results and compliance information to architect.

Set: 27.0

Doors: 184, 212

Description: Classroom Function - STC Assembly

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F05 - SFIC Temp Core AUCN 8808FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Wall Stop - L02101 406 US32D RO

Notes: Seals at frame perimeter and sill by STC door assembly manufacturer.

Set: 28.0

Doors: 105, 108, 109, 120, 201, 202, 204, 205, 206, 208B, 210, 211, 213, 214, 215, 217, 218, 219

Description: Office / Entry Function - STC Assembly

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F04 - SFIC Temp Core AUCN 8807FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

1 Coat Hook 796 US26D RO

Notes: Seals at frame perimeter and sill in lieu of scheduled silencers by STC door assembly manufacturer as indicated.

Refer to drawings and schedules for STC requirements.

All exterior doors on this project shall meet prevailing local standards for windstorm. The door hardware specified is listed as a basis of design.

Work Order Number 1590340

Set: 28.1

Doors: 122, 124, 133, 135, 140, 142, 149, 151, 157, 159, 165, 167

Description: Office / Classroom Function - STC Assembly

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F05 - SFIC Temp Core AUCN 8808FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

Notes: Seals at frame perimeter and sill in lieu of scheduled silencers by STC door assembly manufacturer as indicated.

Refer to drawings and schedules for STC requirements.

Set: 29.0

Doors: 103, 222

Description: Privacy Function + Occupancy Indicator + Closer

3 Hinge A5112 TA2314 NRP 4-1/2" x 4-1/2" US32D MK

1 Lockset - Series 1000 - F02 x Occupancy Indicator AUCN 8802FL - IND 630 YA

1 Closer - C02011 8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Mop Plate - J102 K1050 4" High X 1" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

1 Gasketing - R3D166 x L A R S88D PE

1 Coat Hook 796 US26D RO

Set: 30.0

Doors: 173, 174, 192, 193, 223, 225

Description: Push-Pull + Closer + Gasketing

3 Hinge A8111 T4A3786 NRP 4-1/2" x 4-1/2" US26D MK

1 Push Plate J301, 8" x 16" 70F US32D RO

1 Pull Plate J401, 1" Dia, 10" CTC, 4" x 16" Plate BF 111x70C US32D RO

1 Closer - C02011 8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Mop Plate - J102 K1050 4" High X 1" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

1 Gasketing - R3D166 x L A R S88D PE

Set: 31.0

Doors: 146, 181, 199, 220, 227

Description: Storeroom Function - STC Assembly

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F07 - SFIC Temp Core AUCN 8805FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Wall Stop - L02101 406 US32D RO

3 Silencer - L03011 608 RO

Notes: Seals at frame perimeter and sill in lieu of scheduled silencers by STC door assembly manufacturer as indicated.

Refer to drawings and schedules for STC requirements.

Set: 32.0

Doors: 110, 189

Description: Storeroom Function

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F07 - SFIC Temp Core AUCN 8805FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Overhead Holder - C02511 9-X26 630 RF

3 Silencer - L03011 608 RO

Work Order Number 1590340

Set: 33.0

Doors: 123, 134, 141, 150, 158, 166

Description: Storeroom Function - STC Assembly

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F07 - SFIC Temp Core AUCN 8805FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Overhead Holder - C02511 9-X26 630 RF

3 Silencer - L03011 608 RO

Notes: Seals at frame perimeter and sill in lieu of scheduled silencers by STC door assembly manufacturer as indicated.

Refer to drawings and schedules for STC requirements.

Set: 34.0

Doors: 127A, 138A, 145A, 154A, 162A, 170A, 190B

Description: Exit Only + Monitor Switch - STC Assembly

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Exit Device (exit only) 8810 US32D SA

1 Closer - C02011 8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

1 Position Switch DPS-M-GY (by others) SU

Notes: Seals at frame perimeter and sill by STC door assembly manufacturer.

Door contact switch indicates propped door condition.

Set: 34.1

Doors: 230A, 230C

Description: Storeroom Function - Electrical

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F07 - SFIC Temp Core AUCN 8805FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Closer - C02021, PT4G, PT8C (spring stop) CPS8501T 689 NO

1 Gasketing - R3D166 x L A R S88D PE

Set: 35.0

Doors: 126, 137, 144, 153, 161, 169

Description: Rated Storeroom Function - STC Assembly

3 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Lockset - Series 1000 - F07 - SFIC Temp Core AUCN 8805FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Closer - C02011 8501 689 NO

1 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

1 Wall Stop - L02101 406 US32D RO

Notes: Seals at frame perimeter and sill by STC door assembly manufacturer.

Set: 36.0

Doors: 195A

Description: Storeroom Function Pair + Closer

6 Hinge A8111 T4A3786 NRP 4-1/2" x 4-1/2" US26D MK

1 Dust Proof Strike L04021 570 US26D RO

2 Flush Bolt L04251 555 US26D RO

1 Lockset - Series 1000 - F07 - SFIC Temp Core AUCN 8805FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Closer - C02011 8501 689 NO

2 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

2 Wall Stop - L02101 406 US32D RO

1 Astragal - R5Y63 357SS x Door Height PE

2 Silencer - L03011 608 RO

Notes: Install closer on active leaf.

Overlapping astragal by door manufacturer.

Work Order Number 1590340

Set: 37.0

Doors: 127B, 138B, 145B, 154B, 162B, 170B

Description: Rated Keyed Closet Function Pair - STC Assembly

6 Hinge A8112 TA2714 NRP 4-1/2" x 4-1/2" US26D MK

1 Dust Proof Strike L04021 570 US26D RO

2 Flush Bolt L04251 555 US26D RO

1 Lockset - Series 1000 - F07M- SFIC Temp Core AUCN 8829FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Overhead Stop - C02541 9-X36 630 RF

1 Closer - C02021, PT4G (spring stop) CPS8501 689 NO

2 Kick Plate - J102 K1050 10" High 2" LDW US32D RO

Notes: Seals at frame perimeter, meeting stile and sill by STC door assembly manufacturer.

Install closer on active leaf. Install overhead stop at inactive leaf.

No inside trim on lockset.

Set: 38.0

Doors: 231, 233, 235

Description: Exterior Storeroom Function Pair

6 Hinge A5112 TA2314 NRP 4-1/2" x 4-1/2" US32D MK

2 Surface Bolt L04161 988 Bright ZincSA

1 Lockset - Series 1000 - F07 - SFIC Temp Core AUCN 8805FL K625xCT6SL 630 YA

1 Permanent Combinated Core - SFIC 7300B GMK US15 SA

1 Overhead Holder - C02511 9-X26 630 RF

1 Closer - C02021, PT4G, PT8C (spring stop) CPS8501T 689 NO

1 Threshold - J332133 x HWT x L A R 1715A PE

1 Gasketing x L A R 303CS head & jambs PE

2 Sweep - R3B434 x L A R 315CN x door width PE

2 Position Switch DPS-M-GY (by others) SU

Notes: Install closer on active leaf. Install overhead stop at inactive leaf.

Door contact switch indicates propped door condition.

Overlapping astragal by door manufacturer.

Set: 39.0

Doors: 180, 221A, 221B, 224, 226

Description: Cased Opening

1 Cased Opening No Hardware Required 0

Set: 40.0

Doors: 195B

Description: Overhead Door

1 NOTE: No 087100 Hardware Required OT

Notes: All hardware by door manufacturer.

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LHSP

44LH09

44LH09

16KCS2

16KCS2

10KCS1

28KCS5

28KCS5

32LH10

44LH09

44LH09

36LH10

K

7 20 K

W

X

W

X

W

X

W

X14

W

X55 C2

S-311

W

X

W

X

(E L/

T O

S =1

'-4

(E L/

T O

S =1

'-4

W

X

W

X

W

X

(E L/

T O

S =1

'-4

(E

L/ T

O S

=1

'-4

(E L/

T O

S =1

'-4

(EL/TOS=126'-4")

W30X90

W

X

(E L/

T O

S =1

'-4

(EL/TOS=126'-4")

W30X90

(EL/TOS=126'-4")

W21X50

M A

T C

H

LI

N E

S E

E S

H E

E T

S -1

MATCHLINE

SEE SHEET S-114

SL SL

S L

TYP

R4

(E L

/ B O

T T

O M

'-8

16KCS2

28KCS5

44LH09

44LH09

44LH09

44LH09

W

X

K

K

K

K

K

24K7

30K7

30K10

28LH07

32LH08

32LH09

HSS6X

6X

1/4

HSS6X

6X

1/4

HSS6X

6X

1/4

JBE = 119'-4 1/2"

JBE = 131'-5"

JBE = 119'-4 1/2"

B1

S-312

JBE = 125'- 2 3/4"

JBE = 129'-11 1/2"

B1

S-312

TYP

R2

H S

S

X

X 1/

SIM

SIM

B4

S-312

A1

S-312

W

X

B E

LO

W

E L/

T O

S =1

'-4

W

X

B

E

LO

W E

L/ T

O S

=1

'-4

R E

: A 1/

S -3

W

X

B E

LO

W

E L/

T O

S =1

'-4

B1

S-211

B1

S-211

SIM

TYP

R8

TYP

R8

JB

E

'-8

/2

72KIP

44LH09

1'

0" 1'

0"

44LH09

K

B4

S-211

200#

BOT CHORD

200#

BOT CHORD

150#

BOT CHORD

115#

BOT CHORD

TYP

R1

C1

S-311

A5

S-312 SIM

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 12 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

I C

O R

E N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

IR

G

IN

IA

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

O R

T H

C A

R O

L

IN

A

AS NOTED

P -2

F

-3

T R

A

IN

IN

G

A N

D S

IM

U

L A

T O

R F

A C

IL

IT

Y

1305 EXECUTIVE BLVD.

SUITE 160

CHESAPEAKE, VA 23320

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

1596300

CJC/RMS

MCAS CP

DONALD ELLIOTT

(BY EMAIL)

08 JAN 2020

C

R e v it P ro je c ts

\B L D

G P

-1

-S

-C e n tr a l_ c p y le b u rn s m c d .c o m

.r v t

/6

/2

:0

:5

P

M

S-113

R O

O F

F R

A M

IN

G

P

LA

N

A R

E A

C

DTJ

12804039

CBT ZGA

N40085-20-R-0015

1. REFER TO SHEETS S-001 AND S-002 FOR GENERAL NOTES,

ABBREVIATIONS, PLAN LEGEND AND CALLOUT IDENTIFICATION.

2. REFER TO FOUNDATION PLANS FOR DIMENSIONS NOT SHOWN.

3. REFER TO S-511 THRU S-513 FOR TYPICAL FRAMING DETAILS.

4. ERECTION BRACING CABLES MUST REMAIN IN PLACE UNTIL ALL OF THE

ROOF DECK HAS BEEN INSTALLED AND ANCHORED TO THE MASONRY

SHEAR WALLS.

5. FOR ADDITIONAL INFORMATION ON EQUIPMENT AND EQUIPMENT

WEIGHTS INDICATED ON PLAN, REFER TO MEP DRAWINGS.

COORDINATE EXACT WEIGHT AND LOCATION WITH SUPPLIER.

6. JOISTS DESIGNATED WITH "SP" INDICATE "SPECIAL" AND ARE

REQUIRED TO BE DESIGNED FOR THE ULTIMATE AXIAL LOAD INDICATED

BY A BOX AT THE JOIST END.

ROOF FRAMING PLAN GENERAL NOTES

ROOF FRAMING KEY NOTES RX

PLAN

NORTH

4' 8' 16'0'1/8" = 1'-0" A1

ROOF FRAMING PLAN - AREA C

PLAN

NORTH

A B

C

D

KEY PLAN

R1 UNLESS OTHERWISE NOTED, ROOF CONSTRUCTION MUST CONSIST OF 1

1/2" x 22 GA. TYPE B METAL ROOF DECK. FASTEN DECK TO SUPPORTS WITH

5/8" DIAMETER PUDDLE WELDS AT 36/7 PATTERN OVER SUPPORTS AT 5'-6"

MAX SPACING. FASTEN SIDELAPS TOGETHER WITH #10 TEK SCREWS AT 12"

OC AND FASTEN EDGEMOST DECK PANEL TO STEEL FRAMING WITH 5/8"

DIAMETER PUDDLE WELDS IN EVERY FLUTE. INSTALL 14 GA X 12" WIDE

RIDGE AND VALLEY PLATES, SCREWED TO DECK WITH #10 TEK SCREWS @

12" ON CENTERS.

R2 HATCHING INDICATES 1 1/2" X 18 GA. TYPE B METAL DECK CONTINUOUS

AROUND PERIMETER IN 9FT WIDE STRIPS. FASTEN DECK TO SUPPORTS

WITH 5/8" DIAMETER PUDDLE WELDS AT 36/7 PATTERN OVER SUPPORTS AT

5'-6" MAX SPACING. FASTEN SIDELAPS TOGETHER WITH #10 TEK SCREWS AT

12" OC AND FASTEN EDGEMOST DECK PANEL TO STEEL FRAMING WITH 5/8"

DIAMETER PUDDLE WELDS IN EVERY FLUTE. INSTALL 14 GA X 12" WIDE

RIDGE AND VALLEY PLATES, SCREWED TO DECK WITH #10 TEK SCREWS @

12" ON CENTERS.

R3 2.5K1 JOIST SUBSTITUTE OUTRIGGERS UNDER METAL DECK AT 36" OC MAX.

PROVIDE DOUBLE OUTRIGGERS AT CORNERS AS INDICATED ON PLAN.

R4 INDICATES DECK SPAN DIRECTION.

R5 OPERABLE PARTITION SUPPORT BEAM. W18x65 BOTTOM OF STEEL 115'-10".

COORDINATE WITH OPERABLE PARTITION SUPPLIER. REFER TO

ARCHITECTURAL FOR ADDITIONAL INFORMATION.

R6 WELD PLATE AT TOP OF WALL. SEE DETAIL A1/S-311.

R7 1/4" STEEL PLATE TEE TO SUPPORT ROOF DECK, MATCH JOIST SEAT

HEIGHT

R8 INDICATES BEAM BOTTOM FLANGE BRACING. REFER TO TYPICAL DETAIL ON

SHEET S-511.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

1/

/2

C

O R

R E

C T

E D

D E

TA

IL

R E

F E

R E

N C

E

/0 6/

M

JV

4/6/2020

32LHSP 32LHSP

44LH0944LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

28KCS5

28KCS5

28KCS5

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09 44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

10KCS1

18KCS2

18KCS2

28KCS5

28KCS5

28KCS5

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

44LH09

W

X

W

X

W

X

W

X

W

X

W

X

W

X

W

X

W

X

(E L/

T O

S =1

'-4

(E

L/ T

O S

=1

'-4

(E L/

T O

S =1

'-4

(E L/

T O

S =1

'-4

(E

L/ T

O S

=1

'-4

(E L/

T O

S =1

'-4

W30X90 (EL/TOS=126'-4")

W30X90 (EL/TOS=126'-4")

TYP

R3

MATCHLINE

SEE SHEET S-113

SL SL

TYP

R4

HSS12X10X1/2

(EL/BOT - 112'-8")

44LH09 44LH09

32LH10 32LH10

18KCS2

10KCS1

18KCS2

18KCS2 18KCS2

44LH09

44LH09

B1

S-312

1'

8"

HSS6X

6X

1/4

HSS6X

6X

1/4

JBE = 119'-4 1/2"

JBE = 119'-4 1/2"

W30X90 (EL/TOS=126'-4")

TYP

R2

B1

S-312

SIM

B1

S-312

HSS6X

6X

1/4

W

X

B E

LO

W

E L/

T O

S =1

'-4

R

E : A

1/ S

-3

W

X

B E

LO

W

E L/

T O

S =1

'-4

R

E : A

1/ S

-3

B1

S-211B1

S-211

B1

S-211 B1

S-211

SIM

SIM SIM

JB

E

'-8

/2

53KIP 53KIP

44LH0944LH09

44LH09 44LH09

1'

0" 1'

0"

1'

0" 1'

0"

200#

BOT CHORD

200#

BOT CHORD

150#

BOT CHORD

B4

S-211

SIM

R1

JB

E

'-8

/2

C1

S-311 C1

S-311

A5

S-312

LOW

A5

S-312OPP.

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

DRAWFORM REVISION: 12 APRIL 2018

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

M

ID

-A

T L A

N T

IC

C

I C

O R

E N

A V

A L

S T

A T

IO

N

N

O R

F O

L K

V

IR

G

IN

IA

EJA

M C

A S

C H

E R

R Y

P O

IN

T

C H

E R

R Y

P O

IN

T

N

O R

T H

C A

R O

L

IN

A

AS NOTED

P -2

F

-3

T R

A

IN

IN

G

A N

D S

IM

U

L A

T O

R F

A C

IL

IT

Y

1305 EXECUTIVE BLVD.

SUITE 160

CHESAPEAKE, VA 23320

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

F

IL

E N

A M

E

P

LO

T T

E D

1596300

CJC/RMS

MCAS CP

DONALD ELLIOTT

(BY EMAIL)

08 JAN 2020

C

R e v it P ro je c ts

\B L D

G P

-1

-S

-C e n tr a l_ c p y le b u rn s m c d .c o m

.r v t

/6

/2

:0

:5

P

M

S-114

R O

O F

F R

A M

IN

G

P

LA

N

A R

E A

D

DTJ

12804040

CBT ZGA

N40085-20-R-0015

1. REFER TO SHEETS S-001 AND S-002 FOR GENERAL NOTES,

ABBREVIATIONS, PLAN LEGEND AND CALLOUT IDENTIFICATION.

2. REFER TO FOUNDATION PLANS FOR DIMENSIONS NOT SHOWN.

3. REFER TO S-511 THRU S-513 FOR TYPICAL FRAMING DETAILS.

4. ERECTION BRACING CABLES MUST REMAIN IN PLACE UNTIL ALL OF THE

ROOF DECK HAS BEEN INSTALLED AND ANCHORED TO THE MASONRY

SHEAR WALLS.

5. FOR ADDITIONAL INFORMATION ON EQUIPMENT AND EQUIPMENT

WEIGHTS INDICATED ON PLAN, REFER TO MEP DRAWINGS.

COORDINATE EXACT WEIGHT AND LOCATION WITH SUPPLIER.

6. JOISTS DESIGNATED WITH "SP" INDICATE "SPECIAL" AND ARE

REQUIRED TO BE DESIGNED FOR THE ULTIMATE AXIAL LOAD INDICATED

BY A BOX AT THE JOIST END.

ROOF FRAMING PLAN GENERAL NOTES

ROOF FRAMING KEY NOTES RX

PLAN

NORTH

4' 8' 16'0'1/8" = 1'-0" A1

ROOF FRAMING PLAN - AREA D

PLAN

NORTH

A B

C

D

KEY PLAN

R1 UNLESS OTHERWISE NOTED, ROOF CONSTRUCTION MUST CONSIST OF 1

1/2" x 22 GA. TYPE B METAL ROOF DECK. FASTEN DECK TO SUPPORTS WITH

5/8" DIAMETER PUDDLE WELDS AT 36/7 PATTERN OVER SUPPORTS AT 5'-6"

MAX SPACING. FASTEN SIDELAPS TOGETHER WITH #10 TEK SCREWS AT 12"

OC AND FASTEN EDGEMOST DECK PANEL TO STEEL FRAMING WITH 5/8"

DIAMETER PUDDLE WELDS IN EVERY FLUTE. INSTALL 14 GA X 12" WIDE

RIDGE AND VALLEY PLATES, SCREWED TO DECK WITH #10 TEK SCREWS @

12" ON CENTERS.

R2 HATCHING INDICATES 1 1/2" X 18 GA. TYPE B METAL DECK CONTINUOUS

AROUND PERIMETER IN 9FT WIDE STRIPS. FASTEN DECK TO SUPPORTS

WITH 5/8" DIAMETER PUDDLE WELDS AT 36/7 PATTERN OVER SUPPORTS AT

5'-6" MAX SPACING. FASTEN SIDELAPS TOGETHER WITH #10 TEK SCREWS AT

12" OC AND FASTEN EDGEMOST DECK PANEL TO STEEL FRAMING WITH 5/8"

DIAMETER PUDDLE WELDS IN EVERY FLUTE. INSTALL 14 GA X 12" WIDE

RIDGE AND VALLEY PLATES, SCREWED TO DECK WITH #10 TEK SCREWS @

12" ON CENTERS.

R3 2.5K1 JOIST SUBSTITUTE OUTRIGGERS UNDER METAL DECK AT 36" OC MAX.

PROVIDE DOUBLE OUTRIGGERS AT CORNERS AS INDICATED ON PLAN.

R4 INDICATES DECK SPAN DIRECTION.

R5 OPERABLE PARTITION SUPPORT BEAM. W18x65 BOTTOM OF STEEL 115'-10".

COORDINATE WITH OPERABLE PARTITION SUPPLIER. REFER TO

ARCHITECTURAL FOR ADDITIONAL INFORMATION.

R6 WELD PLATE AT TOP OF WALL. SEE DETAIL A1/S-311.

R7 1/4" STEEL PLATE TEE TO SUPPORT ROOF DECK, MATCH JOIST SEAT

HEIGHT

R8 INDICATES BEAM BOTTOM FLANGE BRACING. REFER TO TYPICAL DETAIL ON

SHEET S-511.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

1/

/2

C

O R

R E

C T

E D

D E

TA

IL

R E

F E

R E

N C

E

/0 6/

M

JV

4/6/2020

P-204 AMENDMENT 003
P-204 AMENDMENT 003 - SPECS
P-204 AMENDMENT 003 - DRAWINGS
12804039 - S-113 - ROOF FRAMING PLAN - AREA C
12804040 - S-114 - ROOF FRAMING PLAN - AREA D

File details come from the government source that posted it. Updated .