1596300spc02of04.pdf
PDF 12 MB Posted
- Solicitation number
- N4008520R0015
About this file
This solicitation is for design-bid-build services for a P-204 F-35 Training and Simulator Facility at Marine Corps Air Station Cherry Point in North Carolina. The Navy seeks proposals by April 9, 2020 for the construction project estimated between $25-100 million. The NAICS code is 236210 for industrial building construction and the small business size standard is $39.5 million. This is an unrestricted solicitation with full and open competition. The wage determination is General Decision Number NC20200065 from January 3, 2020.
View the file
Other files
Show 40 more
Latest 50 of 69 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WORK ORDER NO. 1590340
A/E CONTRACT NO.
N40085-18-D-0600
APPROPRIATION: MCON
P-204 F-35 TRAINING AND SIMULATOR FACILITY
Volume 2 of 4
At the
Marine Corps Air Station, Cherry Point, NC
(P-204)
SUBMITTED BY:
NAVFAC MIDLANT, CI Core 9324 Virginia Avenue
Norfolk, VA 23511
PREPARED BY:
Architectural: Erik Velazquez, R.A.
Structural: R. Christopher Pyle, P.E.
Plumbing/Mechanical: Ryan M. Browning P.E.
Electrical: Luther A. Woodruff, III, P.E.
Fire Protection: Andrew P Leahy, P.E.
Civil: Marty L. Crow, P.E.
Landscape Arch: Stephen L. Stritzl, RLA
Telecommunications: Luther A. Woodruff, III, RCDD
Design Manager (DM):
Rosie M. Shanks, RA, AIA, GPCP.
Date:
ACCEPTED BY:
For Commander, NAVFAC MIDLANT: ___________________________________
Date:
Name: Marty Crow, PE Discipline: Civil
Name: Stephen Stritzl, LS Discipline: Landscape
Name: Christopher Pyle, PE Discipline: Structural
Name: Erik Velazquez, RA Discipline: Architectural
Name: Andrew Leahy, PE Discipline: Fire Protection
Name: Charles W. Southall, PE Discipline: Plumbing, Mechanical
Name: Luther Woodruff, PE Discipline: Electrical
Name: Luther Woodruff, RCDD Discipline: Telecommunications
P-204 F-35 Training and Simulator Facility Work Order Number 1590340 MCAS Cherry Point, North Carolina
PROJECT TABLE OF CONTENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
00 01 15 LIST OF DRAWINGS
00 22 13.00 20 SUPPLEMENTARY INSTRUCTIONS TO OFFERORS
DIVISION 01 - GENERAL REQUIREMENTS
01 11 00 SUMMARY OF WORK
01 14 00 WORK RESTRICTIONS
01 20 00.00 20 PRICE AND PAYMENT PROCEDURES
01 30 00 ADMINISTRATIVE REQUIREMENTS
01 30 01.00 22 DESIGN, PROCUREMENT, AND INSTALLATION OF FURNITURE,
FIXTURES, AND EQUIPMENT
01 31 23.13 20 ELECTRONIC CONSTRUCTION AND FACILITY SUPPORT CONTRACT
MANAGEMENT SYSTEM
01 32 17.00 20 COST-LOADED NETWORK ANALYSIS SCHEDULES (NAS)
01 33 00 SUBMITTAL PROCEDURES
01 33 29 SUSTAINABILITY REPORTING
01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS
01 42 00 SOURCES FOR REFERENCE PUBLICATIONS
01 45 00.00 20 QUALITY CONTROL
01 45 35 SPECIAL INSPECTIONS
01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS
01 57 19.01 20 SUPPLEMENTAL TEMPORARY ENVIRONMENTAL CONTROLS
01 58 00 PROJECT IDENTIFICATION
01 60 00.00 22 REQUIREMENTS FOR PESTICIDE AND HERBICIDE COORDINATION
01 78 00 CLOSEOUT SUBMITTALS
01 78 23 OPERATION AND MAINTENANCE DATA
01 78 24.00 20 FACILITY ELECTRONIC OPERATION AND MAINTENANCE SUPPORT
INFORMATION (eOMSI)
01 78 30.00 22 GIS DATA DELIVERABLES
01 80 00 REPORTS
01 91 00.15 22 TOTAL BUILDING COMMISSIONING
DIVISION 02 - EXISTING CONDITIONS
02 41 00 DEMOLITION
02 61 13 EXCAVATION AND HANDLING OF CONTAMINATED MATERIAL
02 82 00 ASBESTOS REMEDIATION
02 83 00 LEAD REMEDIATION
02 84 16 HANDLING OF LIGHTING BALLASTS AND LAMPS CONTAINING PCBs
AND MERCURY
DIVISION 03 - CONCRETE
03 30 00 CAST-IN-PLACE CONCRETE
DIVISION 04 - MASONRY
04 20 00 UNIT MASONRY
DIVISION 05 - METALS
05 12 00 STRUCTURAL STEEL
05 21 00 STEEL JOIST FRAMING
05 30 00 STEEL DECKS
PROJECT TABLE OF CONTENTS Page 1
05 40 00 COLD-FORMED METAL FRAMING
05 50 13 MISCELLANEOUS METAL FABRICATIONS
05 51 33 METAL LADDERS
05 52 00 METAL RAILINGS
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
06 10 00 ROUGH CARPENTRY
06 20 00 FINISH CARPENTRY
06 61 16 SOLID SURFACING FABRICATIONS
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 05 23 PRESSURE TESTING AN AIR BARRIER SYSTEM FOR AIR TIGHTNESS
07 11 13 BITUMINOUS DAMPPROOFING
07 21 13 BOARD AND BLOCK INSULATION
07 22 00 ROOF AND DECK INSULATION
07 27 10.00 10 BUILDING AIR BARRIER SYSTEM
07 27 19.01 SELF-ADHERING AIR BARRIERS
07 27 26 FLUID-APPLIED MEMBRANE AIR BARRIERS
07 27 36 SPRAY FOAM AIR BARRIERS
07 41 13 METAL ROOF PANELS
07 42 63 FABRICATED WALL PANEL ASSEMBLIES
07 60 00 FLASHING AND SHEET METAL
07 84 00 FIRESTOPPING
07 92 00 JOINT SEALANTS
DIVISION 08 - OPENINGS
08 11 13 STEEL DOORS AND FRAMES
08 14 00 WOOD DOORS
08 31 00 ACCESS DOORS AND PANELS
08 33 23 OVERHEAD COILING DOORS
08 34 73 SOUND CONTROL DOOR ASSEMBLIES
08 41 13 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS
08 44 00 CURTAIN WALL AND GLAZED ASSEMBLIES
08 51 13 ALUMINUM WINDOWS
08 71 00 DOOR HARDWARE
08 81 00 GLAZING
08 91 00 METAL WALL LOUVERS
DIVISION 09 - FINISHES
09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD
09 29 00 GYPSUM BOARD
09 30 10 CERAMIC TILING
09 51 00 ACOUSTICAL CEILINGS
09 62 38 STATIC-CONTROL FLOORING
09 64 29 WOOD STRIP AND PLANK FLOORING
09 65 00 RESILIENT FLOORING
09 66 23.00 22 RESINOUS (EPOXY) TERRAZZO FLOORING
09 67 23.16 FUEL RESISTIVE RESINOUS FLOORING, 5-COAT SYSTEM
09 68 00 CARPETING
09 69 13 RIGID GRID ACCESS FLOORING
09 72 00 WALLCOVERINGS
09 84 20 ACOUSTICAL WALL PANELS
09 90 00 PAINTS AND COATINGS
DIVISION 10 - SPECIALTIES
PROJECT TABLE OF CONTENTS Page 2
10 11 00 VISUAL DISPLAY UNITS
10 14 00.10 EXTERIOR SIGNAGE
10 14 00.20 INTERIOR SIGNAGE
10 21 13 TOILET COMPARTMENTS
10 22 39 FOLDING PANEL PARTITIONS
10 26 00 WALL AND DOOR PROTECTION
10 28 13 TOILET ACCESSORIES
10 51 13 LOCKERS AND BENCHES
DIVISION 12 - FURNISHINGS
12 22 00 CURTAINS AND DRAPES
12 24 13 ROLLER WINDOW SHADES
12 36 00 COUNTERTOPS
12 48 13 ENTRANCE FLOOR MATS AND FRAMES
12 61 13 UPHOLSTERED AUDIENCE SEATING
DIVISION 21 - FIRE SUPPRESSION
21 13 13.00 20 WET PIPE SPRINKLER SYSTEM, FIRE PROTECTION
21 30 00 FIRE PUMPS
DIVISION 22 - PLUMBING
22 00 00 PLUMBING, GENERAL PURPOSE
22 05 48.00 20 MECHANICAL SOUND, VIBRATION, AND SEISMIC CONTROL
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC)
23 00 00 AIR SUPPLY, DISTRIBUTION, VENTILATION, AND EXHAUST SYSTEMS
23 03 00.00 20 BASIC MECHANICAL MATERIALS AND METHODS
23 05 48.00 40 VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT
23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC
23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS
23 09 00 INSTRUMENTATION AND CONTROL FOR HVAC
23 09 13 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC
23 09 23.02 BACNET DIRECT DIGITAL CONTROL FOR HVAC AND OTHER BUILDING
CONTROL SYSTEMS
23 09 93 SEQUENCES OF OPERATION FOR HVAC CONTROL
23 11 25 FACILITY GAS PIPING
23 25 00 CHEMICAL TREATMENT OF WATER FOR MECHANICAL SYSTEMS
23 52 43.00 20 LOW PRESSURE WATER HEATING BOILERS (UNDER 800,000 BTU/HR
OUTPUT)
23 64 10 WATER CHILLERS, VAPOR COMPRESSION TYPE
23 64 26 CHILLED AND HEATING-HOT WATER PIPING SYSTEMS
23 81 23.00 20 COMPUTER ROOM AIR HANDLING UNITS (CRAH)
23 82 00.00 20 TERMINAL HEATING UNITS
DIVISION 25 - INTEGRATED AUTOMATION
25 05 11.01 CYBERSECURITY FOR MCAS ENERGY MONITORING AND CONTROL
SYSTEM (EMCS)
25 05 11.02 CYBERSECURITY FOR HEATING, VENTILATION, AIR CONDITIONING
(HVAC) CONTROL SYSTEM
25 05 11.03 CYBERSECURITY MCAS FIRE ALARM CONTROL SYSTEM (FACS)
25 10 10 UTILITY MONITORING AND CONTROL SYSTEM (UMCS) FRONT END
AND INTEGRATION
PROJECT TABLE OF CONTENTS Page 3
DIVISION 26 - ELECTRICAL
26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS
26 08 00 APPARATUS INSPECTION AND TESTING
26 08 01.00 10 POWER SYSTEM STUDY FOR NEW CONSTRUCTION PROJECTS
26 12 19.10 THREE-PHASE PAD-MOUNTED TRANSFORMERS
26 12 21 SINGLE-PHASE PAD-MOUNTED TRANSFORMERS
26 20 00 INTERIOR DISTRIBUTION SYSTEM
26 24 13 SWITCHBOARDS
26 27 14.00 20 ELECTRICITY METERING
26 29 23 VARIABLE FREQUENCY DRIVE SYSTEMS UNDER 600 VOLTS
26 32 13.00 20 SINGLE OPERATION GENERATOR SETS
26 36 23.00 20 AUTOMATIC TRANSFER SWITCHES
26 41 00 LIGHTNING PROTECTION SYSTEM
26 51 00 INTERIOR LIGHTING
26 56 00 EXTERIOR LIGHTING
DIVISION 27 - COMMUNICATIONS
27 05 29.00 10 PROTECTIVE DISTRIBUTION SYSTEM (PDS) FOR SIPRNET
COMMUNICATION SYSTEMS
27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM
27 54 00.00 20 COMMUNITY ANTENNA TELEVISION (CATV) SYSTEMS
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY
28 31 76 INTERIOR FIRE ALARM AND MASS NOTIFICATION SYSTEM
DIVISION 31 - EARTHWORK
31 05 19 GEOTEXTILE
31 11 00 CLEARING AND GRUBBING
31 21 13 VAPOR MITIGATION
31 23 00.00 20 EXCAVATION AND FILL
DIVISION 32 - EXTERIOR IMPROVEMENTS
32 01 19 FIELD MOLDED SEALANTS FOR SEALING JOINTS IN RIGID
PAVEMENTS
32 05 33 LANDSCAPE ESTABLISHMENT
32 12 13 BITUMINOUS TACK AND PRIME COATS
32 12 16 HOT-MIX ASPHALT (HMA) FOR ROADS
32 13 13.06 PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE
FACILITIES
32 16 19 CONCRETE CURBS, GUTTERS AND SIDEWALKS
32 17 23 PAVEMENT MARKINGS
32 92 23 SODDING
32 93 00 EXTERIOR PLANTS
DIVISION 33 - UTILITIES
33 11 00 WATER UTILITY DISTRIBUTION PIPING
33 30 00 SANITARY SEWERAGE
33 40 00 STORM DRAINAGE UTILITIES
33 61 14 EXTERIOR BURIED PREINSULATED WATER PIPING
33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION
33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)
-- End of Project Table of Contents --
PROJECT TABLE OF CONTENTS Page 4
F-35 Program Information
Export Controlled Information, LM Aero Export Certification Number 98733288
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
(For Additional Releaseability Refer to the Cover Page)
© 2018 Lockheed Martin Corporation
LM Aero REL to 3S Data Links; Abigroup Contractors Pty Ltd.: ADAPS Pty Ltd.: AECOM; Aeronautical and General Instruments Ltd.; Air
Services Australia; Daintree Systems Pty Ltd.: Alenia Aermacchi; Alstec Ltd.; Asplan Viak; Aurecon; Aviation and General Pty Ltd.: Aviation
Requirements Ltd.; Aviation Requirements Ltd.; Babcock Marine (Rosyth) Ltd.; Babcock Support Services Ltd.; BAE Australia; BAE Insyte, BAE Systems; BAE Systems Integrated System Technologies Ltd.; BAE Systems Maritime Services; BAE Systems (Operations) Ltd., acting through its Military Air and Information Organisation; BAE Systems Surface Ships Ltd.; Ballistic Systems Pty Ltd.: Baulderstone Hornibrook
Queensland Pty Ltd.: Boeing Australia Ltd.; Booz Allen Hamilton Ltd.; CAE Professional Services Australia Pty Ltd.: Capital Ships Project
Team Defence Equipment and Support Agency; Coffey Environments; Connell Wagner Pty Ltd.: Cooperative Research Centre for Advanced
Composites Structures Ltd.: ECON; Environmental Resources Management Australia PL; Faveo Prosjektledelse AS; Fincanteri-Canteri; Frazer
Nash Consultancy; GHD Pty Ltd.: Hansen Yuncken; Havelsan Hava Elektronik Sanayi Ve Ticaret A.S.; Hemple (UK) Ltd.: Her Majesty the
Queen In Right of Canada as Represented by the Minister of National Defence; HolteProsjekt as; INBIS; Institute of Sound and Vibration Research
ISVR; International Coatings Ltd.; Jacobs Australia PTY LTD.: John Holland; Kellogg, Brown, and Root Ltd.; Laing O Rourke; Leighs Paints;
Leighton Contractors Pty Ltd.: Lloyds Register EMEA; Lockheed Martin Global Inc; LPO Arkitekter AS; MacTaggart Scott Ltd.; Maker Coatings;
Multiconsult AS; Mincom Ltd.; MPL Group Pty Ltd.: Natural Resources Assessments P-L; Nederlands Centrum voor Interim Management;
Nederlansde Organisatie Voor Toegepast Natuurwetenschappelijk Onderzoek (TNO); Netherlands Organization for Applied Scientific Research;
Nova Defence; Parsons Brinckerhoff Australia Pty Ltd.: PHM Technology Pty Ltd.: Qasco Surveys Pty Ltd.: QinetiQ Ltd.; QinetiQ
AeroStructures; QinetiQ Consulting Pty Ltd.: Rocol Site Safety Systems; Sandal Consultants; Savunma Teknolojileri Muhendisuk ve Ticaret A.S.
(STM); SELEX; Sinclair Knight Merz Pty Ltd.: Stichting Nationaal Lucht-En Ruimtevaartlaboratorium; Sigma Coatings Ltd.; Systems
Consultants Services Ltd.; Teleplan AS; Thales UK Ltd.; Thales Naval Ltd.; Thales Training and Simulation Ltd.; Thales Underwater Systems
Ltd.; The Acoustic Group Ltd.: Tony Smith; Ultra Electronics Ltd.; URS Corporation; URS Australia Pty Ltd.: VT Shipbuilding Ltd.; and
Wikborg, Rein and Co..
F-35 INFORMATION DISCLOSURE WARNING
Distribution of this data is restricted to the entities listed in the “REL TO” statement and is not releasable outside of Lockheed
Martin Corporation or its F-35 Program Teammates, suppliers, customers, or Partners without the advance written approval of the
Joint Program Office for the F-35 Joint Strike Fighter Program.
EXPORT CONTROLLED INFORMATION
WARNING - This document contains technical data whose export is restricted by the Arms Export Control Act (Title 22, U. S.C., Sec. 2751 et seq.) or the Export Administration Act of 1979 (Title 50, U.S.C., App. 2401 et seq.), as amended. Violations of these export laws are subject to severe criminal penalties. Disseminate in accordance with provisions of DoD Directive 5230.25.
A hard copy of this document may not be the document currently in effect. The current version is always the version on the
Lockheed Martin network.
CONTRACT DELIVERABLE
DISTRIBUTION STATEMENT D: Distribution authorized to the Department of Defense (DoD) and U.S. DoD Contractors only;
Critical Technology, August 31, 2016 Other requests shall be referred to the JSF Program Office (JSFPO).
Document No: 2PJG00001, Rev P Date: 23 October 2018
Document Type: CDRL
Data Maturity: FINAL
Lockheed Martin Aeronautics Company CAGE Code: 81755
Contract Number: N00019-18-C-1041
CDRL No.: D00B
F-35 Lightning II Facilities Requirements Document
Section 4: Training Facility Requirements
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
F-35 LIGHTNING II
FACILITIES REQUIREMENTS DOCUMENT
CONTRACT # N00019-18-C-1041
Prepared by:
Lockheed Martin Aeronautics Company, Fort Worth
PO Box 748
Fort Worth, Texas 76101
Cage Code: 81755
Prepared for:
F-35 Joint Program Office
Responsible Point of Contact:
Elizabeth Arnold
817-935-4626
List of Embedded Files
Embedded File Name Header Marking Detail Location
CRB Approval Letter 2018.pdf
Lockheed Martin Proprietary Information
F-35 Program Information
Export Controlled Information, LM Aero Export Certification Number 98733288
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO
MOD, TU MND, UK MOD, NGC, PW
atch
Prepared by:
/Signed/
Elizabeth Arnold
Site & Ship Activation Team
F-35 Lightning II Program
Lockheed Martin Aeronautics
Authorized by:
/Signed/
Robbie Maize
Sr. Mgr, Site & Ship Activation Team
F-35 Lightning II Program
Lockheed Martin Aeronautics
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
TABLE OF CONTENTS
1.0 WEAPON SYSTEM CHARACTERISTICS
2.0 TEST FACILITY REQUIREMENTS
3.0 OPERATIONAL FACILITY REQUIREMENTS
4.0 TRAINING FACILITY REQUIREMENTS
4.1 Introduction
4.1.1 Purpose
4.1.2 Scope
4.1.3 References
4.1.4 Core Accommodations
4.2 Training Facility Description
4.2.1 Number of Personnel
4.2.2 Facility Layout Considerations
4.2.3 Notional Facility Relationship
4.3 Overall Facility Physical Characteristics
4.3.1 Functional Area Space
4.3.2 Ceilings
4.3.3 Access
4.3.4 Windows and Walls
4.3.5 Floor
4.3.6 Acoustics
4.3.7 Heating, Ventilating, and Air Conditioning
4.3.8 Plumbing
4.3.9 Fire Protection System
4.3.10 Electrical
4.3.11 Grounding
4.3.12 Lightning Protection
4.3.13 Lighting
4.3.14 Communications and Information Systems
4.3.15 Security
4.3.16 Environmental, Safety, and Occupational Health
4.3.17 GFE and CFE
4.4 Training System Accommodation Requirements
4.4.1 Full Mission Simulator System
4.4.1.1 FMS Cockpit/OTW Display Room
4.4.1.2 Instructor Operator Station Room
4.4.1.3 Briefing and Debriefing System Room
4.4.1.4 Computer Equipment Room
4.4.1.5 Pilot Training Devices Network Patch Room
4.4.1.6 FMS Global Positioning System Antenna
4.4.1.7 Channels Between Rooms
4.4.1.8 Channels Between Pods
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
4.4.2 Deployable Mission Rehearsal Trainer
4.4.2.1 Shore-based DMRT
4.4.2.2 Shipboard DMRT
4.4.3 Mission Rehearsal Trainer
4.4.4 Simulator Helmet Room
4.4.5 FMS Repair Room and Spares Storage
4.4.6 Aircraft Systems Maintenance Trainer
4.4.7 Ejection System Maintenance Trainer
4.4.8 Weapons Loading Trainer System
4.4.9 Borescope Training Device
4.4.10 F135 Hands-On Engine Training Room
4.4.11 Liftfan Clutch Assembly Trainer
4.4.12 Integrated Power Package Maintenance Trainer
4.4.13 Engine/Liftfan Removal and Installation Trainer
4.4.14 Landing Gear Maintenance Trainer
4.4.15 Outer Mold Line Maintenance Room
4.4.16 Maintainer Training Device Repair Room and Spares Storage
4.4.17 Data Center
4.4.18 Pilot Fit Equipment Lab
4.4.19 Aerospace Ground Equipment Training Room
4.5 Courseware Accommodation Requirements
4.5.1 Pilot EML Classroom
4.5.2 Pilot EML/MP Classroom
4.5.3 Pilot ICW Classroom
4.5.4 Mission Planning Training Classroom
4.5.5 Maintainer EML/ICW Classroom
4.5.6 Learning Resource Center
4.5.7 Student Pilot Laptop Room
4.6 Training System Support Center Accommodation Requirements .. 265
4.6.1 Software Development Center
4.6.2 Classified Development Areas
4.6.3 Database Generation System
4.6.4 Configuration Management Library
4.6.4.1 Classified Configuration Management Library
4.6.4.2 Unclassified Configuration Management Library
4.6.5 Unclassified Development Area
4.7 Administration & Support Accommodation Requirements
4.7.1 Administration Offices
4.7.2 Scheduling Office
4.7.3 Conference Rooms
4.7.4 Lobby, Vestibule
4.7.5 Break Rooms
4.7.6 Instructor Offices
4.7.7 Government Offices
4.7.8 Security Offices
4.8 Pilot Fit Facility (PFF)
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
4.8.1 Head Scanning and HMD Fitting Room
4.8.2 Milling and Visor Trim Room
4.8.3 Below the Neck Fitting Room
4.8.4 Ejection Seat Assembly Fitting Area
4.8.5 Chem-Bio Garment Sizing Area
4.8.6 Pilot Changing Area
4.8.7 Administrative Space/Pilot Reception Area
4.8.8 LM Conference Room/Office
4.8.9 Mechanical Room
4.8.10 Storage Space
4.8.11 Contractor Furnished Equipment/Government Owned Equipment
5.0 DEPOT FACILITY REQUIREMENTS
6.0 SITE SPECIFIC DOCUMENTATION
7.0 SHIPBOARD FACILITY REQUIREMENTS
8.0 ACRONYM LIST
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
LIST OF TABLES
Table 4-1 List of References Table 4-2 Example Eglin AFB ATC Number of personnel Table 4-3 Example: Notional Ops Base Simulator Facility Table 4-4 Functional Area Space Matrix
Table 4-5 Ceiling Height Table 4-6 Floor Surfacing Table 4-7 Floor Loading Matrix Table 4-8 CONUS Training Devices Power Connections Table 4-9 OCONUS Training Devices Power Connections
Table 4-10 Electrical Requirements Key Table 4-11 Electrical Requirements Matrix
Table 4-12 Lighting Levels
Table 4-13 Lighting Control Matrix Table 4-14 Detailed Network Diagram-ICD References Table 4-15 Telecommunications Drops
Table 4-16 Classified Room Matrix Table 4-17 Unclassified Areas Outside Secure Area Table 4-18 FMS Changes by LRIP Contract
Table 4-19 FMS System Equipment Cooling Requirements Table 4-20 Support Equipment by Work Center
Table 4-21 Training Systems GFE/CFE List Table 4-22 Interconnect Rack Power Requirements Table 4-23 MRT System Equipment Cooling Requirements
Table 4-24 ASMT System Equipment Cooling Requirements (LRIP 6 and on)
Table 4-25 ASMT System Equipment Cooling Requirements (Before LRIP 6) Table 4-26 ESMT System Equipment Cooling Requirements Table 4-27 WLT System Equipment Power and Cooling Requirements
Table 4-28 Propulsion HAZMAT Table 4-29 IPP Maintenance Trainer Common Fuselage Dimensions
Table 4-30 OML Maintenance Room Electrical Requirements Table 4-31 Data Center Power Requirements Table 4-32 Data Center Equipment Cooling Requirements Table 4-33 DBGS Equipment Cooling Requirements
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
LIST OF FIGURES
Figure 4-1 Ground Bar Kit Figure 4-2 Training System High Level Network Diagram Figure 4-3 Legend Detailed Network Diagram Figure 4-4 Detailed Network Diagram-Unclassified Operational Environment
Figure 4-5 Detailed Network Diagram-UOE ALIS SOU-U Network Figure 4-6 Detailed Network Diagram-Unclassified Development Environment Figure 4-7 Detailed Network Diagram-Classified Operational Environment Part 1 Figure 4-8 Detailed Network Diagram-Classified Operational Environment Part 2 Figure 4-9 Detailed Network Diagram-Classified Development Environment
Figure 4-10 Detailed Network Diagram-Contractor Support Network (LM Com. Network) Figure 4-11 Large Footprint FMS Pod Layout in 3D view
Figure 4-12 Reduced Footprint FMS Layout Option 1
Figure 4-13 Reduced Footprint FMS Layout Option 2 Figure 4-14 Large Footprint FMS Quad Pod Layout Figure 4-15 Reduced Footprint FMS Quad Pod Layout Option 1
Figure 4-16 Reduced Footprint FMS Quad Pod Layout Option 2 Figure 4-17 FMS Pod Power Cable Maximum Distance Figure 4-18 FMS Pod Signal Cable Maximum Distance
Figure 4-19 Large Footprint FMS Layout, Cable Routing and Interfaces Figure 4-20 Reduced Footprint FMS Option 1 Layout, Cable Routing and Interfaces
Figure 4-21 Reduced Footprint FMS Option 2 Layout, Cable Routing and Interfaces Figure 4-22 FMS EPO System Figure 4-23 Plan view of FMS Out-the-Window (OTW) Display Configuration
Figure 4-24 Recommended Duct Location Layout
Figure 4-25 One of Two Supply Air Ducts for FMS Figure 4-26 Return Air Duct for FMS/MRT/SDC Figure 4-27 FMS Supply and Return Air Duct Location
Figure 4-28 Alternate view of FMS Supply and Return Air Duct Location Figure 4-29 Large Footprint FMS Supply and Return Air Duct Locations
Figure 4-30 Reduced Footprint FMS Supply and Return Air Duct Locations Figure 4-31 FMS Cockpit Cable Track Interface Figure 4-32 FMS Instructor Operator Station (IOS) Figure 4-33 FMS Instructor Operator Station (IOS) Figure 4-34 FMS Briefing Room
Figure 4-35 FMS Single Ship Debriefing Room Layout Figure 4-36 FMS Multi-Ship Debriefing Room Layout
Figure 4-37: Briefing Room Monitor Locations Figure 4-38 Debriefing Room Monitor Locations Figure 4-39 Nominal CE Filter Installation Figure 4-40 FMS Computer Equipment Room, Isometric (ISO) View Figure 4-41 FMS Computer Equipment Room with Maintenance Console
Figure 4-42 Notional FMS Network Patch Room Layout Figure 4-43 Standard Patch Panel Room Rack Setup Figure 4-44 GPS Coax inside SAPF with transceiver in computer equipment room
Figure 4-45: Installation method with coax terminated at SAPF boundary
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
Figure 4-46 Large Footprint FMS Trench, Supply & Return Duct from Center of High Bay ... 141 Figure 4-47 Reduced Footprint FMS Trench, Supply & Return Duct from center of High Bay 142 Figure 4-48 DMRT Primary and Secondary containers Figure 4-49 DMRT Primary Container Showing Access Door Figure 4-50 DMRT Austere Power Requirements
Figure 4-51 DMRT Facility Power Requirements Figure 4-52 DMRT Power Requirement for Overseas Locations Figure 4-53 Notional MRT Cockpit/OTW Display System Configuration Figure 4-54 MRT Cable Routing Figure 4-55 MRT OTW Exhaust Enclosure
Figure 4-56 Nominal CE Filter Installation Figure 4-57 Simulator Helmet Room Layout
Figure 4-58 Simulator HMD Setup Cart and Wall Chart
Figure 4-59 Aircraft System Maintenance Trainer Figure 4-60 ASMT Instructor Station Figure 4-61 ASMT Student Workstation
Figure 4-62 ESMT with Support Brace Figure 4-63 ESMT Configuration Figure 4-64 ESMT with Removable Observation Platform
Figure 4-65 ESMT Front View Figure 4-66 ESMT Top View
Figure 4-67 ESMT Floor Plan Figure 4-68 Notional FLSC TA Layout Figure 4-69 ESMT Facility Electrical Requirements
Figure 4-70 Notional WLT Configuration, ISO View
Figure 4-71 WLT Configuration, Front View Figure 4-72 WLT Configuration, Top View Figure 4-73 WLT Floor Plan
Figure 4-74 Top down view of electrical connection locations for WLT Figure 4-75 Schematic for wiring the connector of the J75400E Electric Weapons Loader
Figure 4-76 WLT Non-Functional Ground Connection Point Figure 4-77 Borescope Training Device Figure 4-78 Borescope Training Device (with computer) Figure 4-79 F135 Hands-On Engine Training Room Figure 4-80 Liftfan Clutch Assembly Trainer
Figure 4-81 IPPMT Notional Configuration Figure 4-82 Preliminary Layout of IPP Maintenance Trainer
Figure 4-83 Non-Functional Ground Connection Point Figure 4-84 ELFRIT Fuselage Assembly Figure 4-85 ELFRIT Facility Floor Layout Figure 4-86 ELFRIT Fuselage Assembly Overall Dimensions Figure 4-87 Location of Nose Gear Stanchion/Plate
Figure 4-88 Emerging conduit should be forward Nose Gear Stanchion/Plate Figure 4-89 ELFRIT Ground Point Locations Figure 4-90 ELFRIT Overhead Crane Alternative
Figure 4-91 LGMT Layout
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
Figure 4-92 OML Maintenance Room Figure 4-93 OML workbench compressed air regulator Figure 4-94 Typical OML classroom student workbench Figure 4-95 Commonly available compressed air hose Figure 4-96 Hazardous Storage Container Example
Figure 4-97 Facility Electrical Requirements Figure 4-98 Recommended 12-Student PFE Lab Layout Figure 4-99: Recommended Six-Student PFE Room Layout Figure 4-100 Typical PFE Lab compressed air regulator Figure 4-101 Commonly available compressed air hose
Figure 4-102 Pilot Electronically Mediated Lecture (EML) Classroom Layout Figure 4-103 Pilot Training System with Panoramic Display and HOTAS
Figure 4-104 Classified Pilot EML Classroom Network Requirements
Figure 4-105 Unclassified Pilot EML Classroom Network Requirements Figure 4-106 Pilot EML/MP Classroom Layout Figure 4-107 Interactive Courseware (ICW) Room Layout
Figure 4-108 Mission Planning Training Room Layout Figure 4-109 Classified Mission Planning Training Network Requirements Figure 4-110 Maintainer EML/ICW Classroom Layout
Figure 4-111 Maintainer EML/ICW Classroom Layout for eight students Figure 4-112 Unclassified Maintainer EML/ICW Classroom Network Requirements
Figure 4-113 Unclassified Learning Resource Center Notional Layout Figure 4-114 Classified Learning Resource Center Notional Layout Figure 4-115 Notional Student Pilot Laptop Room Layout
Figure 4-116 Notional DBGS Configuration
Figure 4-117 Classified Configuration Management Library Figure 4-118 Unclassified Configuration Management Library Figure 4-119 Notional Security Staff Office Space
Figure 4-120 Notional Security Staff Office space in Secure Area Figure 4-121 Notional IAM/ISSO Office space in Secure Area
Figure 4-122 Above the Neck Pilot Flight Equipment Figure 4-123 Below the Neck Pilot Flight Equipment Figure 4-124 Notional Pilot Fit Facility Layout
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
1.0 Weapon System Characteristics
2.0 Test Facility Requirements
3.0 Operational Facility Requirements
4.0 Training Facility Requirements
4.1 Introduction
This document addresses the facility requirements specific to the F-35 Joint Strike Fighter (JSF) training system (TS) for academic training facilities of various sizes with different resource quantities. The requirements specified in this document, when combined with a tailored facility-sizing matrix and recommended functional layout, should provide adequate information to commence the architectural and engineering (A&E) design phase for Integrated Training Centers
(ITCs) (pilot and maintainer training), Pilot Training Centers (PTCs), Maintainer Training Centers
(MTCs), Field Training Detachments (FTDs) and Operational Simulator Facilities.
This Facilities Requirements Document (FRD) outlines minimum requirements. The actual working and storage areas required for each function at the site should be determined upon completion of the facility’s site-specific survey. The A&E design phase should develop the precise layout and total square footage requirements. The requirements stated in this document are limited for the most part to those items required to accommodate the F-35 training system. Ancillary areas within the facility (e.g., corridors, restrooms, etc.) are not specifically identified, as their requirements are dictated by the government’s facility regulations/guidelines and are not F-35 training system specific.
For the purposes of this document, use the term Academic Training Center (ATC) for any facility, which contains classrooms, flight simulators, or maintenance training devices. Current ATC configurations of the F-35 program include the following:
ITCs, which train pilots for their initial and subsequent tours in the F-35 and maintainers for their initial F-35 tour
PTCs, which train pilots for their initial and subsequent tours in the F-35
MTCs, which train F-35 maintainers for their initial tour in the F-35
Flight Simulator Buildings, which provide continuation training for Operational F-35 pilots at the same base as the Operational Squadrons
United States Air Force (USAF) FTDs, which provide transition and continuation training for USAF maintainers only
Multiple organizations within the F-35 program provide various elements of the F-35 training system. The government is generally responsible for facilities availability, to include any real property alterations and or improvements necessary to support program requirements. The host service should ultimately determine how best to meet facilities requirements through new and or existing real property assets. Government/host service responsibilities include building construction, heating, ventilating, and air conditioning (HVAC), electrical, plumbing, physical security systems, fire detection/suppression equipment, telephone infrastructure, furnishings, building systems and other utilities/services, such as compressed air, networks, etc. F-35 program
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
integrated product teams (IPTs) are responsible to provide the required training system components as specified under the applicable Production Contract.
Throughout the document the following terms are used as defined below:
"must" for an obligation
"must not" for a prohibition
"should" for a recommendation
"may" for a discretionary action
4.1.1 Purpose
This document provides the requirements to assist in the programming of new construction and/or alteration of existing facilities for F-35 academic training. The JSF Program Office (JPO) conveys the academic facility requirements as a recommendation to the Host Service. In planning for real property improvements and/or alterations, the Host Service should endeavor to meet the minimum requirements of this document, recognizing individual project programming may include additional Service requirements not necessarily associated with the F-35. In addition to project programming and planning, this document’s content should aid the Host Service in identifying salient functional requirements to a facility design agent, typically a contracted A&E firm to aid in construction project and design development. The A&E must then develop a detailed architectural design that fulfills the facility requirements specified in this document as well as applicable commercial, local, and Host Service building codes and construction criteria. Where a conflict exists between this document and building codes, the A&E firm should default to the more stringent of the two.
4.1.2 Scope
This document lists the requirements for F-35 Training Centers of all types including Simulator
Facilities located at operational bases. This document contains facility requirements for the various components of the F-35 training system. A separate facility-sizing matrix is included with each
Site Specific Activation Plan (SSAP) and indicates the quantity and type of spaces recommended for a specific location along with a recommended functional layout for those spaces.
The combination of this document, the facility-sizing matrix, and the functional layout should provide adequate information for facility budget estimates as well as commencement of the A&E process.
This document contains the Master GFE/CFE list (defined in section 4.3.17). The list should be referenced and tailored for site-specific needs and used during the design review stage to assist the service and A&E firm.
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
4.1.3 References
Table 4-1 List of References
Number Name
AFOSH STD 91-118 Training Systems Fire Protection
AFOSH STD 91-56 Fire Protection And Prevention
DG 1110-3-106 Engineer Design Guide US Army Schools
DoD 5220.22-M
(NISPOM)
National Industrial Security Program Operating Manual (NISPOM)
ETL 02-12 Communications and Information System Criteria for Air Force
Facilities
ICD 705 Sensitive Compartmented Information facilities
JSIG Joint Special Access Program (SAP) Implementation Guide
MIL-HDBK-419A Grounding, Bonding, And Shielding For Electronic Equipments And
Facilities
MIL-HDBK-274A Department Of Defense Handbook: Electrical Grounding For Aircraft
Safety
MIL-STD-1472 Department Of Defense Design Criteria Standard: Human Engineering
MIL-STD-1686 Electrostatic Discharge Control Program For Protection Of Electrical
And Electronic Parts, Assemblies And Equipment
MIL-STD-188-124B GROUNDING, BONDING AND SHIELDING for Common Long
Haul/Tactical Communication Systems Including Ground Based
Communications-Electronics Facilities and Equipments
NEC 250 Grounding And Bonding National Electrical Code
Article 250
NFPA 12 Standard on Carbon Dioxide Extinguishing Systems
NFPA 70 National Electrical Code (NEC)
NFPA 72 National Fire Alarm and Signaling Code
NFPA 780 Standard for the Installation of Lightning Protection Systems
TIA/EIA-607 Grounding And Bonding Requirements For Telecommunications
UFC 3-575-01 Lightning and Static Electricity Protection Systems
UFC 4-171-01N Design: Aviation Training Facilities Architectural Graphic Standards (by Ramsey Sleeper)
UFC 3-301-01 UFC Structural Engineering
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
4.1.4 Core Accommodations
The core accommodation requirements address the following training devices (TDs)/operations areas.
Pilot:
Full Mission Simulator (FMS)
Deployable Mission Rehearsal Trainer (DMRT)
Mission Rehearsal Trainer (MRT)
FMS Mission Briefing Facilities
FMS Mission Debriefing Facilities
Maintenance:
Aircraft Systems Maintenance Trainer (ASMT)
Ejection System Maintenance Trainer (ESMT)
Weapons Loading Trainer (WLT)
F135 Hands-On Engine Trainer
Liftfan Clutch Assembly Trainer
Integrated Power Package Maintenance Trainer (IPPMT)
Engine/Liftfan Removal and Installation Trainer (ELFRIT)
Landing Gear Maintenance Trainer (LGMT)
Outer Mold Line (OML) Maintenance Room
Additional core accommodation requirements address other training facility rooms, such as:
Pilot EML Classrooms
Pilot ICW Classrooms
Maintainer EML/ICW Classrooms
4.2 Training Facility Description
ATC training uses instructor-led classroom activities, self-paced independent study via Interactive
Courseware Workstations (ICWs), training in virtual simulators, and training on various aircraft component mock-ups. The ATC also contains Autonomic Logistics Information System (ALIS) equipment needed to support the F-35 training system. In addition to the instructional capabilities mentioned above, the ATC contains all the administrative, operational, instructor, and support personnel necessary to operate the facility.
The JSF ITC Simulation Model is used to determine the number of training resources required to support a given student/pilot throughput. The ground rules and assumptions for the ITC Model that impact the training resource determination are on the F-35 Joint Data Library (JDL) at the following locations:
Link:
https://edcs-jsf.lmaeronautics.com/jsf/livelink/open/15697168
JDL Drill Down:
Data Library
Collaborative Workspaces ...
2000 - F-35 Sustainment https://edcs-jsf.lmaeronautics.com/jsf/livelink/open/15697168 https://aztecsc.jsfvpc.lmtas.com/jsf/livelink?func=ll&objId=2001&objAction=browse&sort=name https://aztecsc.jsfvpc.lmtas.com/jsf/livelink?func=ll&objId=14176223&objAction=browse&sort=name https://aztecsc.jsfvpc.lmtas.com/jsf/livelink?func=ll&objId=8859192&objAction=browse&sort=name
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
2300 - Training System
2300 - Tier 4 IPTs***FULL...
2360 Integrated Training ...
ITC Simulation Model ***F...
File Name: ITC Simulation Model Ground Rules & Assumptions *** Releasable Non-Technical
Data for ITAR ***
4.2.1 Number of Personnel
Each training center is sized to accommodate a specific number of students, instructors, technicians, and Training Systems Support Center (TSSC) personnel in single shift or dual shift operations. Training system maintenance and reconfiguration of components in preparation for the next day may require an additional shift Table 4-2 and
Table 4-3 are intended to allow A&E firms to estimate the facility requirements for personnel and are not to be used in site-specific facility design. Personnel estimates for training centers are developed using the ITC Simulation Model, as described in Section 4.2, during the SSAP event.
These initial personnel estimates are included in the site-specific sizing matrix described in Section
4.1.2. The site-specific sizing matrix should be used for initial facility designs, these personnel estimates are refined as the site activation process matures and documented in the interim contractor support (ICS) plan in found in Section 1.8.11 of the FRD.
Table 4-2 provides an example of the types and numbers of personnel using the Eglin Air Force
Base (AFB) ATC, personnel numbers for an ATC for another service may vary based upon student/pilot throughput. The Eglin AFB ATC personnel numbers were developed using the ITC
Simulation Model and refined in the site activation process.
Table 4-2 Example Eglin AFB ATC Number of personnel
Example: ATC Eglin AFB
Gov't Contractor
Pilot Students 120
Maintainer Students 316
Site Management 4 42
Simulation Technicians 0 38
Academic Pilot Instructors 15 40
Maintenance Instructors 120
Training System Support Center 5 91
Subtotals 580 211
Total 791
Table 4-3 provides an example of the types and numbers of personnel using a Simulator Facility at a notional operations base. The notional operations base personnel numbers represent a facility supporting only four pilot simulators. The actual numbers will vary based on the number of assigned pilots and the number of simulators needed to provide training.
https://aztecsc.jsfvpc.lmtas.com/jsf/livelink?func=ll&objId=8859205&objAction=browse&sort=name https://aztecsc.jsfvpc.lmtas.com/jsf/livelink?func=ll&objId=14913747&objAction=browse&sort=name https://aztecsc.jsfvpc.lmtas.com/jsf/livelink?func=ll&objId=14913426&objAction=browse&sort=name
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
Table 4-3 Example: Notional Ops Base Simulator Facility
Example: Notional Ops Base Sim Facility (4 FMS)
Gov't Contractor
Pilots 12
Site Management 2 2
Simulation Technicians 0 6
Contract Pilot Instructors 4
Subtotals 14 12
Total 26
4.2.2 Facility Layout Considerations
Detailed facility designs should account for the following criteria:
Minimize student/pilot and staff foot traffic and crossing over patterns
Consider noise mitigation to prevent interference from adjacent rooms and other base activity
Locate simulators and mock-ups adjacent to exterior doors
Classified areas should be placed in a single section of the facility when possible, allow for red/black separation and equipment layout separation from unclassified areas
Communications equipment room (CER) and telecommunication closets (TCs) should not be located near building utility rooms or generators to minimize electromagnetic interference (EMI) issues
Provide for all necessary building operations and maintenance provisions, or special built-in features to allow for the performance of all necessary building and maintenance operations without disruption to training
Design with future expansion in mind, such that maintainer training devices, for example, would be located adjacent to potential facility additions
4.2.3 Notional Facility Relationship
Each training center should develop a relationship diagram detailing the recommended adjacency relationships and traffic flow for the training. Each training center will have a recommended functional layout specified in the appropriate SSAP for that basing location.
4.3 Overall Facility Physical Characteristics
Overall Facility Physical Characteristics applies to the overall training facility; additional information, details, and specifications follow in the remainder of the document. All training related rooms within the facility will address the requirements for the following attributes: area, ceilings, access, windows and walls, floor, acoustics, HVAC, plumbing, fire protection system
(FPS), lighting, communications and information systems, security, environmental safety and occupational health (ESOH), and government-furnished equipment (GFE)/contractor-furnished equipment (CFE).
4.3.1 Functional Area Space
This section of the document contains square footage estimates for facility areas. These estimates are based on one or more of the following factors:
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
USAF Standards, Naval Facilities Engineering Command (NAVFAC) Standards, Military Standards (MIL STD) and Corps of Engineering Standards
Unified Facilities Criteria (UFC)
Commercial Building Codes
F-35 minimum space requirements
Facility Planners should also take into account Service Specific Requirements, Country Specific requirements, and EU compliance. To reduce construction costs the A&E firm may combine certain areas, such as the repair shops or storage to the extent, the design constraints listed in this document are not materially compromised.
Table 4-4 shows the recommended component square footage for each space in the facility-sizing matrix. Lockheed Martin (LM) generates a site-specific matrix for each training center location with the recommended quantities for each type of space. Each of the areas listed in Table 4-4 are not necessarily required for each facility. Support spaces should relate to staffing and population levels. The sizes of the support spaces in Table 4-4 are sized based on a training operation of eight
FMSs, two ASMTs, one ESMT, and one WLT. A version of the sizing matrix can be seen at the below JDL link:
https://edcs-jsf.lmaeronautics.com/jsf/livelink?func=ll&objId=82309646&objAction=browse&viewType=1
Table 4-4 Functional Area Space Matrix
Room Description Unit
Unit (m2 ) Unit (ft2
Training Infrastructure Systems
Classified Data Center (Total)
Operational Systems Servers
TMS/LMS Integrated Classified Configuration 27 2.51
Growth 27 2.51
TSNI - IT Admin 27 2.51
Classroom Workstation Racks 27 2.51
Development Systems Servers
CW/LMS 27 2.51
PTA Development 27 2.51
Training Devices 27 2.51
IT Admin 27 2.51
TMS/LMS Integrated CLAS Configuration 27 2.51
UPS & Power Distribution 160 14.86
Department Internal Circulation 15%
Unclassified Data Center (Total)
Operational Systems Servers https://edcs-jsf.lmaeronautics.com/jsf/livelink?func=ll&objId=82309646&objAction=browse&viewType=1 https://edcs-jsf.lmaeronautics.com/jsf/livelink?func=ll&objId=82309646&objAction=browse&viewType=1
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
CW/LMS 27 2.51
TMS (Training Mgmt. System) 27 2.51
Growth #1 27 2.51
ALIS SOU (U) 27 2.51
Product Maintenance (Distribution Server) 27 2.51
IT Admin 27 2.51
Performance Assessment 27 2.51
Classroom Workstation Racks 27 2.51
Development Systems Servers
TMS (Training Mgmt. System) 150 13.94
CW/LMS 54 5.02
Training Devices 27 2.51
IT Admin 27 2.51
UPS & Power Distribution 160 14.86
Department Internal Circulation 15%
Network Rooms
Classified
Central Network Room 208 19.32
Distributed Network Room (A) 79 7.34
Unclassified
Central Network Room 154 14.31
Distributed Network Room (A) 79 7.34
TSSC Development Areas
Classified Developer Area (shared) #1 90 8.36
Classified Build Room 180 16.72
Software Development Center (SDC)/Mission Rehearsal
Trainer (MRT) 986 91.6
TD Software Development Environment (SDE) #1 95 8.83
TD Database Generation System (DBGS) #1 600 55.74
TD Database Generation System (DBGS) #2 600 55.74
TSSC Manager's Office
TSSC Manager Office 150 13.94
TSSC Developer's Office
Software Quality Assurance 90 8.36
Functional Support Team Lead and Systems Eng Mgr 90 8.36
Configuration Management 90 8.36
Problem Management/Ops Desk 90 8.36
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
Logistics Support Engineering 90 8.36
Test Engineer 90 8.36
Instructional Product Support Team Lead 90 8.36
Pilot and Maintainer SME 90 8.36
Courseware Developer 90 8.36
Media Specialist 90 8.36
TMS DB SW Engineer 90 8.36
TD Product Support Team Lead and SW Eng Mgr 90 8.36
Training Device Database Generation System (DBGS) 90 8.36
TSSC Office Space
TSSC Secretarial / Admin 90 8.36
File Area - Unclassified 20%
Conference Room - Unclassified 375 34.84
Conference Room - Classified 375 34.84
Shared Office Equipment 450 41.81
TSSC Break Room 66 6.13
Configuration Management Library (UNCL) 375 34.84
Configuration Management Library (CLASS) 275 25.55
File Area - Classified 3%
Department Internal Circulation 15%
Courseware
Maintainer EML/ICW Classroom (16 seat) 1200 111.48
Maintainer EML/ICW Classroom (8 seat) 750 69.7
Pilot EML Classroom - Unclassified 1200 111.48
Pilot EML Classroom - Classified 1200 111.48
Pilot ICW Workstation Room - Unclassified 613 56.95
Pilot ICW Workstation Room - Classified 613 56.95
Mission Planning Training Room - Classified 1200 111.48
Learning Resource Center (LRC) * 2354 218.72
Learning Resource Center (LRC) – Classified* 500 46.45
Department Internal Circulation 15%
Training Devices
FMS Repair Shop 600 55.74
FMS Maintenance Storage Area (4 FMS) 140 13
Reduced Footprint FMS (Cockpit/OTW Display) 1200 111.5
Large Footprint FMS (Cockpit/OTW Display) 1505 139.8
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
FMS Electrical/Mechanical/Computer Equip Room (1 per
FMS)
360 33.45
FMS Instructor/Operator Station 225 20.90
FMS Pod Hallway 125 11.15
FMS Pilot Brief Room (4-Ship) 330 30.66
FMS Pilot Debrief Room (4-Ship) 440 40.88
FMS Brief/Debrief Small Server room 66 6.13
FMS Network Patch Room 280 26.01
Simulator Helmet Room 400 37.16
DMRT (Interior installation) 600 55.74
TD Repair Shop (Maintenance Devices) 600 55.74
TD Maintenance Spares (Maintenance Devices) 140 13
Weapons Load Trainer (WLT) 5600 520.26
Storage of Training Weapons 980 91.04
Aircraft Systems Maintenance Trainer (12 Seat) 1200 111.48
Aircraft Systems Maintenance Trainer (8 Seat) 900 89.61
Ejection System Maintenance Trainer 4200 390.19
Outer Mold Line (OML) Maintenance Room 1482 137.68
PFE Lab 1500 137.68
Hands-On Engine Trainers 1550 144
Borescope Trainer Room 400 37.16
Liftfan Clutch Assembly Trainer Room 500 46.45
Integrated Power Package Maintenance Trainer (IPPMT) 952 88.44
Engine/Liftfan Removal and Installation Trainer (ELFRIT) 6300 585.29
Landing Gear Maintenance Trainer (LGMT) 5375 499.354
Department Internal Circulation 15%
Fork Truck Circulation for Selected Areas 65%
Government
Government Director 250 23.23
Government Deputy Director 250 23.23
Government Offices 90 8.36
Government Break Room 72 6.69
Administration and Support
Training Operations Mgr 200 18.58
Administrative Assistant 90 8.36
Quality 90 8.36
Training Support Manager 150 13.94
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
Facility Services 90 8.36
Spares Clerk 90 8.36
Shipping/Receiving Clerk 90 8.36
Instructional Manager 150 13.94
Support Manager 150 13.94
Registrars 90 8.36
Schedulers 90 8.36
File Area - Government & Contractor 20%
Office and General Supply Room 200 18.58
Reproduction Area 115 10.68
Office Break Areas 150 13.94
Security Manager 150 13.94
Security Generalist 90 8.36
Classified Area Equipment 350 32.52
IAM/ISSO 90 8.36
Contract Pilot Instructor Work Stations 90 8.36
Contract Pilot Instructor Work Stations – Classified 90 8.36
Contract Pilot Instructor Mgt. Work Stations 130 12.08
Contract Pilot Instructors File Area 20%
Supply, Shipping & Receiving Area 1400 130.06
Warehouse Area 2557 237.55
Conference Room - Government 375 34.84
Conference Room - Operation Manager 375 34.84
Conference Room - Training Manager's 375 34.84
Conference Room - Large General Use 690 64.1
Conference Room - Classified 375 34.84
Conference Room - Instructor 375 34.84
Lobby 1132 105.17
Vestibule 80 7.43
Auditorium 1950 181.16
A/V Room for Auditorium 250 23.23
Mail Room 100 9.29
Telecommunication Closets (TC) 763 70.89
Communications Equipment Room (CER) 500 46.45
Security Mantrap Room 108 10.03
Pilots Student Break Room 309 28.71
LM Aero REL TO US DOD, AU DOD, CA DND, DK MOD, IT MOD, NL MOD, NO MOD, TU MND, UK MOD, NGC, PW
Use or disclosure of the information contained herein is subject to the restrictions on the cover page.
Contract Pilot Instructor Break Room 120 11.15
Student Pilot Laptop Room 600 55.7
Maintenance Training Squadron (MTS)
US…
This is the start of the file's text. The full file is on GovTribe.