10 51 13.pdf

PDF 18 KB Posted

Attached to
P303, DESIGN-BID-BUILD, MARINE CORPS RESERVE CENTER, CAMP FRETTERD MD
Solicitation number
N4008021R6986
Issued by

About this file

This solicitation is for the construction of a new Marine Corps Reserve Center, vehicle maintenance facility, and organic storage shed at Camp Fretterd, Maryland. The project involves constructing a single-story reserve center facility of approximately 35,130 square feet that will include an armory, drill hall, lockers, showers, classrooms, fitness center, supply storage, offices, and a covered weapons cleaning area. It also includes constructing a single-story vehicle maintenance facility of approximately 10,968 square feet with vehicle bays, offices and a carpentry shop, and an outdoor vehicle wash platform. A single-story organic storage shed of approximately 4,000 square feet with a steel frame and metal siding will also be constructed. The solicitation was issued by the Department of the Navy, Naval Facilities Engineering Command for design-build services. Responses are due based on the solicitation schedule.

View the file

Other files

File Type Posted
P303 AMENDMENT 0007.pdf PDF
P303 AMENDMENT 0006.pdf PDF
P303 Amendment 0005.pdf PDF
BLDG-P303-1624797_C_A-002.pdf PDF
P303 Revised Price Schedule 1NOV2021.doc DOC document
BLDG-P303-1624797_C_A-200.pdf PDF
1624807Amendment4SPECS.pdf PDF
08 71 00.pdf PDF
BLDG-P303-1624797_A_A-601 Revised.pdf PDF
BLDG-P303-1624797_A_A-303.pdf PDF
32 31 13.pdf PDF
1624807Amendment4DWG.pdf PDF
1624807Amendment4.docx DOCX document
BLDG-P303-1624797_A_A-631.pdf PDF
07 05 23.pdf PDF
08 71 00C.pdf PDF
Revision Description (10-26-2021).docx DOCX document
P303 Amendment 0004.pdf PDF
P303-AMENDMENT 0003.pdf PDF
FFE FINAL - Building A.pdf PDF
SID Package - Building B.pdf PDF
SID Package - Building A.pdf PDF
BLDG-P303-1624797_A_A-601.pdf PDF
P303 Amendment 0002.pdf PDF
P303 Site Visit Sign-In Sheet.pdf PDF
C-508.pdf PDF
C-501.pdf PDF
E-601.pdf PDF
ST101.pdf PDF
CS400.pdf PDF
26 20 00.pdf PDF
32 15 00.pdf PDF
P303 Amendment 0001.pdf PDF
40 95 00.pdf PDF
CS410.pdf PDF
COMBINED CIVIL DRAWINGS 2 of 2.pdf PDF
COMBINED CIVIL DRAWINGS 1 of 2.pdf PDF
ATTACHMENT E - SAFETY DATA SHEET.docx DOCX document
BLDG A COMBINED DRAWING.pdf PDF
P303 Final Volume 3 Specs.pdf PDF
1624807DWGBLDGC1of1.pdf PDF
SF1442 - N40080-21-R-6986.pdf PDF
ATTACHMENT D - CONSTRUCTION EXPERIENCE PROJECT DATA SHEET.docx DOCX document
Visitor Access Request List.xlsx XLSX spreadsheet
Small Business Subcontracting Plan.doc DOC document
P303 Final Volume 1 Specs.pdf PDF
BLDG B Combined Drawings.pdf PDF
SITE-VISIT PARKING AREA.png PNG image
ATTACHMENT F - SMALL BUSINESS PAST PERFORMANCE.docx DOCX document
P303 Final Volume 2 Specs.pdf PDF
Show 40 more

Latest 50 of 55 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P-303 Marine Corps Reserve Center - BLDG A & C W.O. No. 1624797 Camp Fretterd, Reisterstown, MD AMMENDMENT 6

SECTION 10 51 13

METAL LOCKERS

05/11

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM A1008/A1008M (2016) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable

ASTM B456 (2017) Standard Specification for Electrodeposited Coatings of Copper Plus Nickel Plus Chromium and Nickel Plus Chromium

U.S. GENERAL SERVICES ADMINISTRATION (GSA)

FS AA-L-00486 (Rev J) Lockers, Clothing, Steel

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for Contractor Quality Control approval. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING.

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES:

SD-02 Shop Drawings

Types ; G

Location ; G

Installation

Numbering system

SD-03 Product Data

Material

Locking Devices

Lock Control Chart

Handles

SECTION 10 51 13 Page 1

UNCLASSIFIED//FOR OFFICIAL USE ONLY (FOUO)

Finish

Locker components

Locker Benches

Assembly instructions

SD-04 Samples

Color chips ; G

1.3 DELIVERY, HANDLING, AND STORAGE

Deliver lockers and associated materials in their original packages, containers, or bundles bearing the manufacturer's name and the name of the material. Protect from weather, soil, and damage during delivery, storage, and construction.

1.4 FIELD MEASUREMENTS

To ensure proper fits, make field measurements prior to the preparation of drawings and fabrication. Verify correct location

1.5 QUALITY ASSURANCE

1.5.1 Color Chips

Provide a minimum of three color chips, not less than 3 inches square, of each color .

Government may request performance-characteristic tests on assembled lockers. Tests and results must conform to FS AA-L-00486 . Lockers not conforming will be rejected.

PART 2 PRODUCTS

2.1 TYPES

Locker must have the following type and size in the location and quantities indicated. Locker finish colors will be as scheduled.

2.1.1 Double-Tier

Double-tier lockers must be as follows:

Type DTW-3: Double-tier Z style locker 12 inches wide, 18 inches deep, and 60 inches high, without base

Type DTL-3: Double-tier gear locker 36 inches wide, 36 inches deep, and 72 inches high, attached to 6 inch high legs

SECTION 10 51 13 Page 2

2.2 MATERIAL

2.2.1 Galvanized Steel Sheet

ASTM A1008/A1008M , commercial quality, minimized spangle material.

Prepare material surfaces for powder coat paint finishing in accordance with FS AA-L-00486 . Fabricate locker bodies from not less than 0.0239-inch thick steel sheet.

2.2.2 Chromium Coating

Nickel and chromium electrodeposited on the specified base metal. Conform to ASTM B456, SC-3, as applicable to the base metal.

2.2.3 Finish

FS AA-L-00486 .

2.2.3.1 Color

As selected.

2.3 COMPONENTS

2.3.1 Built-In Locks

FS AA-L-00486 . Provide locking devices as built-in key locks.

2.3.2 Coat Hooks

FS AA-L-00486 , chromium plated.

2.3.3 Hanger Rods

FS AA-L-00486 .

2.3.4 Door Handles

FS AA-L-00486 . Provide zinc alloy or steel handles with a chromium coating.

2.3.5 Doors

FS AA-L-00486 , not less than 0.0598 inch thick steel sheet. Provide perforated or meshed steel door for gear locker.

2.3.5.1 Hinges

In addition to the requirements of FS AA-L-00486 , provide 5-knuckle hinges, minimum 2 inches high. Fabricate knuckle hinges from not less than

0.0787 inch thick steel sheet. A full height piano hinge may be provided if standard with the manufacturer. Weld or bolt hinges to the door frame. Weld, bolt, or rivet hinges to the door.

2.3.5.2 Latching Mechanisms

FS AA-L-00486 .

SECTION 10 51 13 Page 3

2.3.6 Latch Strikes

FS AA-L-00486 . Fabricate from not less than 0.0787 inch thick steel sheet, except latch strike may be continuous from top to bottom and fabricated as part of the door framing.

2.3.7 Silencers

FS AA-L-00486 .

2.3.8 Back and Side Panels, Tops, and Bottoms

FS AA-L-00486 , not less than 0.0474 inch thick steel sheet. Provide perforated or meshed steel side panels for gear locker.

2.3.9 Shelves

FS AA-L-00486 . Fabricate from not less than 0.0598 inch thick steel sheet.

2.3.10 Legs

FS AA-L-00486 .

2.3.11 Number Plates

FS AA-L-00486 . Aluminum. Provide consecutive numbers from 01 to as counted on plan .

2.3.12 Label Holders

FS AA-L-00486 .

2.3.13 Fastening Devices

Provide bolts, nuts, and rivets as specified in FS AA-L-00486 .

2.4 Locker Benches

Provide Wood Locker Benches in light finishes. Wood seat to be constructed of solid butcher block wood, benches are 9.5 inches deep, 18 inches high.

Coordinate length of the bench with overall locker and bench design from the drawing. Provide two single-post with cover plate pedestals, bolt mounted in powder coated fininsh.

PART 3 EXECUTION

3.1 ASSEMBLY AND INSTALLATION

Assemble lockers according to the locker manufacturer's instructions.

Align lockers horizontally and vertically. Secure lockers to wall and base with screws as indicated. Bolt adjacent lockers together. Adjust doors to operate freely without sticking or binding and to ensure they close tightly.

3.2 NUMBERING SYSTEM

Install number plates on lockers consecutively with odd numbers on top and

SECTION 10 51 13 Page 4 even numbers on bottom.

3.3 FIELD QUALITY CONTROL

3.3.1 Testing

Government may request performance-characteristic tests on assembled lockers in accordance with FS AA-L-00486 . Lockers not conforming will be rejected.

3.3.2 Repairing

Remove and replace damaged and unacceptable portions of completed work with new.

3.3.3 Cleaning

Clean surfaces of the work, and adjacent surfaces soiled as a result of the work, in an approved manner. Remove equipment, surplus materials, and rubbish from the site.

-- End of Section --

SECTION 10 51 13 Page 5

File details come from the government source that posted it. Updated .