N3220520R4051_0007.docx
DOCX document 34 KB Posted
- Attached to
- USNS SUPPLY ROH/DD Federal contract opportunity
- Solicitation number
- N3220520R4051
About this file
This document provides answers to questions regarding solicitation number N3220520R4051 for repair, overhaul, and drydocking of the USNS Supply. The solicitation involves standard work items for categories A and B. Key work includes propeller and rudder stock clearances, exhaust plenum repairs, firefighting system inspections, potable water tank cleaning and painting, line shaft bearing inspection and replacement, gas turbine intake inspection and repair, oily water separator installation, and drydocking and hull preservation services. The Navy's Military Sealift Command is the contracting agency, and the document provides additional clarification to support offerors in developing proposals for the work on the USNS Supply.
View the file
Other files for this federal contract opportunity
Show all 27
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N3220520R4051
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION B - SUPPLIES OR SERVICES AND PRICES
The following have been added by full text:
AMENDMENT 7 RFCS
SPECIFICATION ITEM NO.: 917
PARAGRAPH / SECTION NO: 7.1.1
TITLE: Propeller and Rudder Stock Clearances
QUESTION: 57
According to drawings, the propeller fairwaters are bolted on. It states that “new fairwaters shall be fit at reassembly”. Please specify if new propeller fairwaters are to be installed and who is to furnish the new fairwaters.
ANSWER: Fairwaters are welded as per Para 7.2.1. Contractor is to furnish new fairwaters
SPECIFICATION ITEM NO.: 540
PARAGRAPH / SECTION NO: NA
TITLE: E1-257-1 Exhaust Plenum Repairs
QUESTION: 58
Please clarify scope of work. Spec says Replace removed section with 11 gage stainless steel. From the photos, it looks like the area to be removed is actually the plenum bulkhead. Is this the intent or is there a duct inside the plenum.
Also, please advise sizes of the 2 screens. The reference drawing is frame 393-459. The item location says frame 245-260 ------01 Level Port side--
ANSWER: It is the Duct work internal to the Plenum, Interior Plenum Bulkhead bottom section ( wasted lower area) and the screen lip external to the bulkhead duct internal to the plenum. See additional pictures for Screen size. The Location is correct. I have been unable to locate a drawing for the location. However, all of the main deck plenums are designed the same. See attached Previous work item for REFERENCE ONLY
SPECIFICATION ITEM NO.: 502
PARAGRAPH / SECTION NO: 2.1
TITLE: Firefighting System Annual Inspections
QUESTION: 59
Please provide the following references:
MSC SWI 28 Firefighting System Inspection and Testing DWG. 6360224-Circuit FH Sprinkling Alarm Circuit DWG. 8394052 Fire and Smoke Detection DWG. 8394456 Fire and Smoke Detection DWG. 8394038 Halon Damper Install
ANSWER: Please see attached. Please substitute DWG 8390433_B for DWG 8394052 and substitute DWG8390875 for DWG 839456
SPECIFICATION ITEM NO.: ________________________________
PARAGRAPH / SECTION NO: __________________________________
TITLE: __Vessel Availability for Ship Check_________________________
QUESTION: 60
Please advise if MSC is able to provide an additional ship check date.
ANSWER: The Sister Ship USNS ARCTIC is in Detyens Shipyard. USNS Supply Is deployed until the end of June. If additional ship check dates are needed please contact John.bolan@navy.mil for access to the ship. Ship checkers will need to complete Detyens Shipyard Covis-19 Check list prior to requesting access to the yard and ship
SPECIFICATION ITEM NO.: ___917_____________________________
PARAGRAPH / SECTION NO: __7.1_____________________________
TITLE: __Propeller and Rudder Stock Clearances____________________
QUESTION: 61
7.1.1 states that the propeller fairwater is welded on, new fairwaters shall be fit at reassembly. Please clarify if only propeller fairwaters (items 9 - 10 in Dwg 6360800) are to be new and fit at reassembly or if all fairwaters (items 5 - 10 in Dwg 6360800, not to include the coupling covers) are to be new and fit at reassembly.
ANSWER: Propeller fairwaters only. If other fairwaters require replacement that will be done with a CCO
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
C – 2 List of Standard WIs included for this solicitation:
CATEGORY A
| 0001 | INTENT, SCOPE, GENERAL CONDITION AND DEFINITIONS |
| 0002 | TECHNICAL AND MANUFACTURER’S REPRESENTATIVES |
| 0003 | APPROACH, BERTH AND MOORING REQUIREMENTS |
| 0004 | TESTING AND QUALITY ASSURANCE |
| 0005 | ELECTRICAL SAFETY PROCEDURE REQUIREMENTS |
| 0006 | HEAVY WEATHER PLAN |
| 0007 | COLD WEATHER PLAN |
| 0010 | FURNISH OFFICE FOR OVERHAUL MANAGEMENT TEAM |
| 0011 | GENERAL SERVICES FOR SHIP, T-AOE |
| 0012 | INFORMATION TECHNOLOGY SERVICES |
| 0013 | PROJECT PLANNING AND PRODUCTION STATUS MONITORING REPORTS |
| 0014 | WEIGHT AND MOMENT REPORT |
| 0015 | INTEGRATED LOGISTICS AND GFM SUPPORT REQUIREMENTS |
| 0016 | FIRE PROTECTION AND SHIP'S SAFETY PROGRAM |
| 0017 | HANDLING OF SHIP'S STORES |
| 0018 | DELIVERY AND REDELIVERY OF THE VESSEL |
| 0019 | SHIPBOARD ACCESS AND SECURITY |
| 0020 | GAS FREE CERTIFICATES |
| 0021 | CLEAN AND GAS FREE TANKS, VOIDS, AND COFFERDAMS |
| 0022 | MACHINERY SPACE TURNOVER, DOCK TRIALS AND SEA TRIALS |
| 0023 | HAZARDOUS WASTE DISPOSAL AT CONTRACTOR’S FACILITY |
| 0024 | PHYSICAL SECURITY AT PRIVATE CONTRACTOR'S FACILITY |
| 0101 | SHIP YARD SUPPORT FOR ABS SURVEY |
| 0103 | TANK INSPECTION AND BOUNDARY TESTING (ABS) |
| 0104 | TANK ENTRANCE COMBING REPAIR (3C & 4C) |
| 0105 | FLIGHT DECK SAFETY NET REPAIRS |
| 0107 | FLIGHT DECK DRAIN PIPING REPLACEMENT |
| 0110 | AFT CHT TANKS MAINTENANCE COAT REV |
| 0111 | FWD CHT TANKS MAINTENANCE COAT REV - FWD |
| 0112 | FWD AFT MSD V1 AND V2 TANKS CLEANING AND PAINTING |
| 0113 | WEATHERDECK HANDRAILS, BULWARK EDGES REPLACEMENT |
| 0114 | REPLACE 04 LEVEL NON SKID |
| 0115 | REPLACEMENT OF STEEL DECK BENEATH STATION 9 TOPPING WINCH |
| 0116 | LADDER PLATFORM INSERT REPAIR |
| 0117 | SHAFT ALLEY WORKING PLATFORM (T-ALT 17-326) |
| 0120 | CARGO TIE DOWN DECK SOCKET REPLACMENT |
| 0125 | CARGO TLI SYSTEM SENSOR INSTALL |
| 0133 | POTABLE WATER TANKS CLEANING AND PAINTING |
| 0201 | LINE SHAFT BEARINGS OPEN & INSPECT |
| 0209 | PORT AND STBD LINE SHAFT BEARING REACTIONS |
| 0215 | GAS TURBINE INTAKE INSPECTION AND REPAIR |
| 0301 | STUFFING TUBE REPLACEMENT |
| 0310 | SSDG TOP END OVERHAUL (20,000 HR) SSDG 2 & 5 |
| 0315 | CAPSTAN CONTROLLER OVERHAUL AND REPAIR |
| 0328 | SSDG HEAT EXCHANGER REPAIRS (TWO SSDG) |
| 0329 | SSDG FUEL OIL COOLER REPLACEMENT |
| 0401 | GMDSS SAFETY RADIO CERTIFICATION |
| 0402 | RADAR PREVENTATIVE MAINTENANCE |
| 0403 | ANTENNA PREVENTATIVE MAINTENANCE |
| 0406 | UHF TRANSCEIVER GROOM |
| 0407 | OE-82B ANTENNA GROUP MAINTENANCE |
| 0410 | FATHOMETER PREVENTATIVE MAINTENANCE AND REPAIR |
| 0411 | 1B CLUTCH CANNON PLUG REPLACEMENT |
| 0412 | S/Y SUPPORT FOR PELCO CAMERA INSTALLATION |
| 0413 | STEERING CONTROL CIRCUIT CARD MAINTENANCE |
| 0415 | GYROCOMPASS AND REPEATER GRROM |
| 0428 | TV-DTS SATELLITE SYSTEM UPGRADES (T-AOE 6-13-023R) |
| 0501 | ASSIST SHIPS FORCE |
| 0502 | FIREFIGHTING SYSTEM ANNUAL INSPECTION |
| 0503 | SCBA COMPRESSOR MAINTENANCE AND CERTIFICATION |
| 0504 | PORT AND STBD RHIB DAVIT INSPECTION |
| 0505 | PORT AND STBD RHIB INSPECTION |
| 0506 | AUXILARY BOILER INSPECTION |
| 0510 | PALLET CONVEYOR RESTORATION |
| 0513 | LAGING AND INSULATION REPAIR |
| 0514 | PIPING REPAIRS REV B |
| 0515 | ASSIST L3 BUILD 26 SUPPORT AND ETHERNET REDUNDANT LOOP |
| 0516 | REPLACE PURIFIER FLEX HOSES |
| 0517 | WATERTIGHT DOOR REFURBISHMENT |
| 0518 | AIR COMPRESSOR GROOM AND REPAIR |
| 0525 | FAIRLEAD CONTROLLER INSPECTION |
| 0530 | STEERING PUMP OVEHAUL |
| 0531 | MISC EQUIPMENT AND MOTOR OVERHAUL |
| 0535 | PIPING REPAIRS VARIOUS |
| 0536 | CARGO REFRIGERATION PLENUM REPAIRS |
| 0539 | AMR HALON FIRE DAMPERS INSTALLATION |
| 0540 | E1-257-1 EXHAUST PLENUM REPAIRS |
| 0541 | INSTALL GAS TURBINE FUEL SENSORS IN FUEL OIL SERVICE SYSTEM (ABS) |
| 0542 | INSTALL SSDGs AND AUX BOILERS FUEL SENSORS IN FUEL OIL SERVICE SYSTEM (ABS) |
| 0543 | DEGAUSSING QIQP COIL CONDUIT PRESERVATION |
| 0552 | STEERING AND RUDDER ANGLE INDICATOR CHECKS |
| 0555 | INSTALL OILY WATER SEPARATOR (OWS) UNIT TA301 |
| 0601 | GALLEY AND SCULLERY EQUIPMENT MAINTENANCE |
| 0604 | LIFE RAFTS AND EMBARKATION LADDER CERTIFICATION |
| 0606 | INTERIOR TILE REPLACEMENT WITH STRATICA FLOORING |
| 0607 | INTERIOR CPC DECK REPLACMENT REV 1 |
| 0608 | INTERIOR CPC DECK REPLACMENT CPO |
| 0801 | HABITABILITY SPACES VENT SYSTEMS CLEANING |
| 0901 | DRY-DOCKING AND UNDOCKING VESSEL |
| 0903 | SEA VALVES |
| 0904 | RUDDER AND STERN FRAME EXAMINATION |
| 0905 | BILGE KEEL EXAMINATION |
| 0906 | CATHODIC PROTECTION SYSTEM MAINTENANCE |
| 0907 | CATHELCO PROTECTION SYSTEM PREVENTATIVE MAINTENANCE |
| 0908 | ZINC RENEWAL |
| 0909 | ULTRA SONIC TESTING |
| 0910 | CHAIN AND LOCKER PAINTING |
| 0911 | HULL FREEBOARD CLEANING AND PAINTING |
| 0912 | HULL FREEBOARD CLEANING AND PAINTING 30% |
| 0913 | MAIN PROPULSION SHAFTING |
| 0914 | REPLACE STERN TUBE SHAFT BEARING LINERS |
| 0915 | PROPELLER CLEAN AND REPAIR |
| 0916 | PROPELLER SHAFT INSTALLATION PREPARATIONS |
| 0917 | PROPELLER AND RUDDER STOCK CLEARANCES |
| 0918 | SEA SUCTION AND DISCHARGE LINES (ABS) |
| 0919 | FOREPEAK TANK REPAIR (ABS OSR) |
| 0920 | PORT & STBD ANCHOR WINDLASS BRAKE REPAIR |
| 0921 | SHELL PLATE WELDING AND REPAIR (ABS OSR) |
| 1002 | HIGH PRESSURE AIR RELIEF VALVE CALIBRATION |
| 1003 | TOPPING WINCH FOUNDATION AND WINCH REFURB |
| 1004 | GYPSY WINCH FOUNDATION AND WINCH REPAIRS |
| 1005 | SLIDING BLOCK CHAIN REPLACEMENT |
| 1006 | WINCH CONTROL BOOTH WINDOW REPLACEMENT, LATCHES AND STOPS |
CATEGORY B
| 0025 | PHYSICAL SECURITY AT PRIVATE CONTRACTOR'S FACILITY IN FORCE PROTECTION | CONDITIONS CHARLIE – DELTA |
| 0030 | CONTINUATION OF SERVICES | |
| 0304 | STUFFING TUBE REPLACEMENT | |
| 0305 | MULTIPLE CABLE TRANSIT REPAIRS | |
| 0513 | LAGGING AND INSULATION REPAIR | |
| 0902 | DRY DOCKING AND UNDOCKING VESSEL | |
| 0928 | SHELL PLATE AND WELDING REPAIR | |
| 0929 | STEEL RENEWAL | |
| 0932 | ULTRASONIC TESTING |
(End of Summary of Changes) image1.wmf
File details come from the government source that posted it. Updated .