0102_A_STRUCTURAL INSPECTIONS REV A.docx

DOCX document 40 KB Posted

Attached to
USNS SPEARHEAD Federal contract opportunity
Solicitation number
N32205-15-R-4006
Issued by
Department of the Navy Military Sealift Command

About this file

WI 0102

View the file

Other files for this federal contract opportunity

Other files attached to USNS SPEARHEAD, newest first.
File Type Posted
N32205-15-R-4006-0005.doc DOC document
0910_A_RIDE_CONTROL_SCF_BEARING_SUPPORT_REV_A_(TALT_XXR).docx DOCX document
RFP_Q_ _A_10.docx DOCX document
0011_A_GENERAL_SERVICES_FOR_SHIP_REV_A.docx DOCX document
J_-_1_SPEARHEAD-_ROH_WI_Index_ROH.docx DOCX document
0304_A_MODIFY_EXTERIOR_FLOOD_LIGHTING_REV_A.docx DOCX document
AMENDMENT_N32205-14-R-4006-0004.doc DOC document
RFP_Q_ _A_11.docx DOCX document
J_-_2_Category_A_Items_Spearhead_ROH.xls XLS spreadsheet
RFP_Q_ _A_13.docx DOCX document
RFP_Q_ _A_10.docx DOCX document
RFP_Q_ _A_11.docx DOCX document
RFP Q A 6.docx DOCX document
RFP Q A 9.docx DOCX document
RFP Q A 8.docx DOCX document
RFP Q A 7.docx DOCX document
RFP Q A 12.docx DOCX document
N32205-15-R-4006-03.doc DOC document
0510_A_REBUILD FIREPUMP REV A.docx DOCX document
0302_A_ PLC SURVEY REV A.docx DOCX document
0101_A_ INSPECT FLIGHT DECK TIE DOWNS REV A.docx DOCX document
RFP_Q_ _A_2.docx DOCX document
RFP_Q_ _A_3.docx DOCX document
0803_A_HVAC SYSTEM ANNUAL MAINT REV A.docx DOCX document
0011_A_GENERAL SERVICES FOR SHIP REV A.docx DOCX document
0908_B_REMOVE WATERJET JETAVATOR REV A.doc DOC document
J A_Mod_1_OEM_Reps_-_USNS_SPEARHEAD_(FebBizOps).docx DOCX document
RFP_Q_ _A_4.docx DOCX document
0609_A_FIRE DOOR MAINT REV A.docx DOCX document
0304_A_MODIFY_EXTERIOR_FLOOD_LIGHTING REV A.docx DOCX document
0910_A_RIDE CONTROL SCF BEARING SUPPORT REV A —
RFP_Q_ _A_5.docx DOCX document
0906_A_RIDE CONTROL SYSTEM MAINT REV A.docx DOCX document
AMENDMENT_N32205-15-R-4006-02.doc DOC document
0907_A_WATERJET MAINTENANCE REV A.docx DOCX document
0903_A_ INSPECT SEA VALVES AND SEA CHESTS REV A.docx DOCX document
0506_A_TEST MAIN AIR RECEIVERS REV A.docx DOCX document
0905_A_INSPECT AND REPAIR UW HULL COATING REV A.docx DOCX document
N32205-15-R-4006_P00001.doc DOC document
RFP-RFQ_Q_ A__1.docx DOCX document
N32205-15-R-4006.doc DOC document
Spearhead_J A.PDF PDF
SPHD_15-R-4006_J_Attachments.zip ZIP file
SPHD_15-R-4006_CDRLS.zip ZIP file
Show all 44

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USNS SPEARHEAD

(JHSV 1)

HULL STRUCTUREN32205-15-R-4006
31 MAY 2015
ITEM NO. 0102Category “A”MSC/PALANDRO/RP

STRUCTURAL INSPECTIONS REV A

1.0 ABSTRACT

1.1 This item describes structural inspections of areas identified on JHSV-1.

2.0 REFERENCES

2.1 JHSV_Structural_Inspection_Guide_

2.2 8443364_F General_Arrangement

2.3 8444521_A Tunnel FR 8-24

2.4 8444522_A Tunnel FR 25-41

2.5 8444524_A Tunnel FR 52-70

3.0 ITEM LOCATION/DESCRIPTION

3.1 Location

3.1.1 Various per 2.1

3.1.2 Tunnel Void 2-7-0

4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICE: NONE

5.0 NOTES

5.1 The contractor and all subcontractors, regardless of tier must consult the General Technical Requirements (GTR) to determine applicability to this work item. In performance of this work item, the contractor and all subcontractors regardless of tier must comply with the requirements of all applicable GTR’s.

5.2 The contractor and all subcontractors, regardless of tier are advised to review other work items under this contract to determine their effect on the work required under this work item. Many of the definitions relating to performance of this work item are found in Work Item 001.

5.3 The contractor shall furnish the services of an ABS approved Non-Destructive Test Inspection and Analysis company.

6.0 QUALITY ASSURANCE REQUIREMENTS

6.1 The contractor shall document the findings as stated in this SOW and provide a report.

7.0 STATEMENT OF WORK REQUIRED

7.1 Furnish access to locations for inspections identified to include removal of man-hole covers, scaffolding, lighting, ventilation and removal of insulation.

7.2 Furnish services of Marine Chemist to certify spaces for inspection as “Safe for Man”.

7.3 Restore inspected areas to as found condition to include replacement and repair of insulation. All manhole covers shall be replaced with new gaskets.

7.3.1 Procure and install lagging pads in areas with removed insulation. Pads shall match existing color and fire rating. Secure pads with stainless fasteners and wire.

7.4 Furnish the services of an ABS approved Non-Destructive (NDT) Services Company to examine the following locations using 5X visual inspection in accordance with NAVSEA Technical Publication T9074-AS-GIB-010/271, is acceptable:

7.4.1 All locations identified in reference 2.1. (86 page document)

7.4.2 Tunnel Void 2-7-0: All welds on Frames 7,16,24,32,41,52,70 only in the location of the Tunnel area 2-7-0 will be gas free IAW WI 0021.

7.5 Record the results of the inspections. Deficiencies shall be by digital photograph and documented by location description and finding. Provide an electronic copy of the completed document with photographs to MSC REP.

7.6 Provide all staging, gas free and labor required to weld repair a total of 20 (twenty) crack locations found during para 7.4 inspection. Assume cracks will be 4 inches in length.

7.7 Manufacturer’s Representative:NONE

8.0 General Requirements: None additional.

0102-3