Mech 035 - Pages 8-19.pdf

PDF 3 MB Posted

Attached to
Y1DA--504-18-119 Replace Boilers and Piping Federal contract opportunity
Solicitation number
36C25722R0010
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17

About this file

This document package includes mechanical drawings and flow diagrams for a boiler replacement project at the Veterans Affairs Medical Center in Amarillo, Texas. The project involves demolishing existing boilers and related piping and installing new boilers, steam and condensate piping, fuel oil piping and associated equipment. Drawings show demolition plans, new piping layouts, and isometric diagrams. The related federal contract opportunity is solicitation number 36C25722R0010 for project 504-18-119 to replace the boilers and piping. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 17 for this project at the Amarillo VAMC.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--504-18-119 Replace Boilers and Piping, newest first.
File Type Posted
Past Performance Questionnaire.pdf PDF
Answers to Questions 36C25722R0010 DB Replace Boilers.pdf PDF
VA NOTICE OF LIMITATIONS ON SUBCONTRACTING REQUIREMENT.pdf PDF
Amendment 36C25722R0010 0001.docx DOCX document
36C25722R0010_1.docx DOCX document
Mech 035 - Pages 7-12.pdf PDF
Phasing sheets.pdf PDF
Struct 035.pdf PDF
SELF-PERFORMED CALCULATIONS.pdf PDF
BP-2-Boilers-natgasandpropane.pdf PDF
20-09 035 Narrative 02 1r1 Phasing Narrative.pdf PDF
20-09 035 Narrative 06 1r1 Civil-LS Design Narrative.pdf PDF
20-09 035 Narrative 13 1r1 Specs TOC 000110 035 21-06-30.pdf PDF
AS ST Series Sheets.pdf PDF
AD AE Series Sheets.pdf PDF
Elect 035.pdf PDF
G Series Sheets.pdf PDF
BP-4-Water-Treatment.pdf PDF
Mech 035 - Pages 1-3.pdf PDF
Mech 035 - Pages 4-6.pdf PDF
OSHA - EMR requirement.pdf PDF
BP-3-Boiler-steam.pdf PDF
BP-1-Boiler-fueloil.pdf PDF
Show all 23

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EMERGENCY BY-PASS

VACUUM

BREAKER

ROOF

LPS 2#

V

L P

S

0-15 PSIG

LPS 5# 2"

N.C.

BY-PASS

0-200 PSIG

11-PRV1

0-100 PSIG

11-PRV2

MPS 65# LPS 5#

PRESSURE SENSING LINE

TO PILOT (TYP.)

PRESSURE REDUCING STATION No.1

STEAM

TRAP

11-ST4

STEAM

TRAP

11-ST3

HPS 70#

HP STEAM ORIFICE

BOILER ROOM FLOOR

FIRETUBE BOILER

B

D /2

125 HP

CONDENSATE

FROM FACILITY

SKIDMORE

UNIT

VACUUM

CONDENSATE

RECEIVER

VACUUM COND.

FROM FACILITY

SURGE TANK

RO WATER FROM

WATER TREATMENT

30#VAC-15 PSIG

SV SET @

15 PSIG

30-

300F

CONDENSATE

TRANSFER

PUMP #2

CONDENSATE

TRANSFER

PUMP #1

TO BOILER PLANT

BLDG. HEATING

SOFTWATER FROM

WATER TREATMENT

CONDENSATE

FROM BOILER PLANT

BOILER

FEED

PUMP #1

BOILER

FEED

PUMP #2

BOILER

FEED

PUMP #3

LP COND. FROM

BOILER PLANT

CONDENSATE

FILTER

TO HIGH PRESS.

STEAM DIST.

LC

OVERFLOW

CHEMICAL

FEED POT

ECONOMIZER

BOILER PLANT

HW HEATER

LC

HAND VALVE

PRESSURE RELIEF VALVE

REGULATOR VALVE

LEVEL CONTROL VALVE

LEGEND

EMERGENCY BY-PASS

LC

BY-PASS

EMERGENCY BY-PASS

V

V

DEAERATING

FEED TANK

H

BOILER PLANT

STEAM

FLOW RECORDER

ORIFICE

HPS 90#

-1

/2

STEAM

SILENCER

FIRETUBE BOILER

V

H P

S

0-200 PSIG

HPS

H P

S /4

PRESSURE

TRANSMITTER

STEAM

TRAP

11-ST2

D 3/4"D 3/4"

D

D

H P

S

STEAM

TRAP

11-ST1

200 HP

3/4"

(TYP.)

FIRETUBE BOILERFIRETUBE BOILER

B

B

B

MAIN STEAM HDR.

BOILER STEAM OPERATION

METER ORIFICE, TYP.

4"

4"

4"

HPS 70#

HPS 70#

3/4" VENT

3/4" VENT

3/4" VENT

D /2

D /2

D /2

200 HP200 HP

4"

LC LC LC

CHEMICAL

FEED POT

CHEMICAL

FEED POT

CHEMICAL

FEED POT

H P

S

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:5

:0

P M

M-400

MECHANICAL FLOW DIAGRAMS -

WATER AND STEAM - DEMOLITION

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

NO SCALE

BOILER PLANT-WATER & STEAM FLOW DIAGRAM - DEMOLITION

Revisions: Date:

EMERGENCY BY-PASS

DEAERATING

FEED TANK

250 HP

BOILER

D /2

250 HP250 HP

BOILER BOILER

B

B

B

NORMALLY OPEN

HEADER VALVE

ROOF

LPS 2#

V

L P

S

# 2

0-15 PSIG

LPS 5# 2"

N.C.

BY-PASS

0-200 PSIG

11-PRV1

0-100 PSIG

11-PRV2

MPS 65# LPS 5#

PRESSURE SENSING LINE

TO PILOT (TYP.)

PRESSURE REDUCING STATION No.1

STEAM

TRAP

11-ST4

STEAM

TRAP

11-ST3

HPS 70#

HP STEAM ORIFICE

FIRETUBE BOILER

B

D /2

125 HP

CONDENSATE

FROM FACILITY

SKIDMORE

UNIT

VACUUM

CONDENSATE

RECEIVER

VACUUM COND.

FROM FACILITY

SURGE TANK

RO WATER FROM

WATER TREATMENT

30#VAC-15 PSIG

SV SET @

15 PSIG

30-

300F

CONDENSATE

TRANSFER

PUMP #2

CONDENSATE

TRANSFER

PUMP #1

TO BOILER PLANT

BLDG. HEATING

SOFTWATER FROM

WATER TREATMENT

CONDENSATE

FROM BOILER PLANT

BOILER

FEED

PUMP #1

BOILER

FEED

PUMP #2

BOILER

FEED

PUMP #3

LP COND. FROM

BOILER PLANT

CONDENSATE

FILTER

TO HIGH PRESS.

STEAM DIST.

LC

OVERFLOW

TO

BLOWDOWN

SEPARATOR

CHEMICAL

FEED POT

ECONOMIZER

BOILER PLANT

HW HEATER

LC

HAND VALVE

PRESSURE RELIEF VALVE

REGULATOR VALVE

LEVEL CONTROL VALVE

LEGEND

EMERGENCY BY-PASS

LC

VACUUM

BREAKER

BOILER ROOM FLOOR

BY-PASS

EMERGENCY BY-PASS

VV

D /2

D /2

LC LC LC

0-200 PSIG

H P

S /4

STEAM

TRAP

11-ST2

8"

STEAM

SILENCER

V

0-200 PSIG

HPS

H P

S /4

PRESSURE

TRANSMITTER

STEAM

TRAP

11-ST2

D 3/4"

D

D

H P

S T E

A M

D

IS

T R

IB

U

T

IO

N

MAIN STEAM HDR.

D 3/4"

HPS

PRESSURE

TRANSMITTER

-1

/2

H P

S T E

A M

D

IS

T R

IB

U

T

IO

N

B -4

B -2

B -3

B -1

8"

FMFMFM STEAM

FLOW

METER

(TYP.)

NEW

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:4

:2

P M

M-401

MECHANICAL FLOW DIAGRAMS -

WATER AND STEAM

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

NO SCALE

BOILER PLANT-WATER & STEAM FLOW DIAGRAM

BRINE

PUMP

BRINE

TANK

#3 WATER

SOFTENER REVERSE

OSMOSIS

SYSTEM #2

R.O. WATER

STORAGE

TANK #1

RO TRANSFER

PUMP #1

3" HW

" M

2" B

N.C.

" H

W

" H

W

R.O. WATER

STORAGE

TANK #2

6"

CHARCOAL

FILTER

" H

W

#2 WATER

SOFTENER

#1 WATER

SOFTENER

REVERSE

OSMOSIS

SYSTEM #1

3/4" HOT WATER

WATER

TEMPERING

STATION

3/4" HOT WATER

WATER

TEMPERING

STATION

CHARCOAL

FILTERS

OUTDOOR BRINE TANKS

TRUCK FILL

CONNECTION

BRINE

TANK #1

BRINE

TANK #2

BRINE

TANK #3

BRINE

TANK #4

RO TRANSFER

PUMP #2

TOWER WATER

(HARD)

SOFT WATER

TO SURGE TANK

TO BOILER

SURGE TANK

WASTE

WATER

TO DRAIN

WASTE

WATER

TO DRAIN

TO BOILER

PLANT

TO HOSPITAL

CHECK VALVE

HAND VALVE

Y-TYPE STRAINER

METER

LEGEND

REDUCER

M

3" SW

DD

D

REPLACE EXISTING WATER

SOFTENERS IN PLACE. REVIEW

FLOW AND WATER QUALITY

REPORT TO PROPERLY SIZE.

LLC

O F

L

/4

R

O

M

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:5

:0

P M

M-402

MECHANICAL FLOW DIAGRAMS -

WATER TREATMENT

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

NO SCALE

WATER TREATMENT FLOW DIAGRAM

ST

M

ST

ST

M

M M

PS

PS

M S

T

M M

PS

PS

M S

T

M M

PS

PS

M S

T

S

S

V

FLAME

ARRESTOR

S

S

ST

ST

M

M M

PS

PS

M

ST

HP

BOILER

#4

HP

HP

HP

BOILER

#1 BOILER

#2

BOILER

#3

FUEL OIL

TANK #3

FUEL OIL

TANK #2

FUEL OIL

PUMP #1

FUEL OIL

PUMP #2

FUEL RATIO

VALVE

FUEL RATIO

VALVE

FUEL RATIO

VALVE

FUEL RATIO

VALVE

REMOVE AND

REPLACE

FUEL OIL PIPING TO

BOILERS#1,2&3

(TYP.)

BOILER FUEL OIL

TRAIN TO BOILER#4

TO

REMAIN

REMOVE AND

REPLACE ALL

FUEL OIL

PIPING.

REMOVE AND

REPLACE FUEL

OIL PUMPS.

BUILDING

LINE.

FLUE

DISCHARGE

FLUE

DISCHARGE

FLUE

DISCHARGE

FLUE

DISCHARGE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:0

:1

P M

M-403

MECHANICAL FLOW DIAGRAMS -

BOILER - FUEL OIL - DEMOLITION

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

NO SCALE

BOILER - FUEL OIL DIAGRAM - DEMOLITION

ST

M

ST

ST

M

M M

PS

PS

M S

T

M M

PS

PS

M S

T

M M

PS

PS

M S

T

S

S

V

FLAME

ARRESTOR

S

S

M

M M

PS

PS

M

S T

HP

BOILER

#4

HP

HP

HP

BOILER

#1 BOILER

#2

BOILER

#3

FUEL OIL

TANK #3

FUEL OIL

TANK #2

FUEL OIL

PUMP #1

FUEL OIL

PUMP #2

FUEL RATIO

VALVE

FUEL RATIO

VALVE

FUEL RATIO

VALVE

FUEL RATIO

VALVE

(ETR) (ETR)

NEW STRAINERS

AND VALVES

NEW FUEL OIL

PUMPS

NEW STRAINERS

AND FILTRATION

EXTERIOR PIPING

TO REMAIN

NEW

METERS

(TYP.)

BOILER FUEL OIL

TRAIN TO BOILER#4 TO

REMAIN

NEW FUEL OIL TRAIN

TO BOILERS

(TYP. 1, 2, & 3)

FLUE

DISCHARGE

FLUE

DISCHARGE

FLUE

DISCHARGE

FLUE

DISCHARGE

BUILDING

LINE.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:0

:1

P M

M-404

MECHANICAL FLOW DIAGRAMS -

BOILER - FUEL OIL

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

NO SCALE

BOILER - FUEL OIL DIAGRAM

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:5

:1

P M

M-601

BOILER PLANT DEMO ISOMETRIC

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

N O R

HT

BOILER PLANT DEMOLITION - ISOMETRIC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:5

:1

P M

M-602

BOILER PLANT NEW WORK ISOMETRIC

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

N O R

HT

BOILER PLANT NEW WORK ISOMETRIC

File details come from the government source that posted it. Updated .