G Series Sheets.pdf
PDF 1 MB Posted
- Attached to
- Y1DA--504-18-119 Replace Boilers and Piping Federal contract opportunity
- Solicitation number
- 36C25722R0010
About this file
This document package includes architectural drawings and specifications for a federal construction project to replace boilers and piping at a Department of Veterans Affairs medical center. Key project details include replacing existing boilers, installing a new deaerator tank and related equipment in two phases, replacing steam tunnels, repairing or replacing the building roof, repairing exterior walls, replacing heat exchangers and modernizing steam and condensate systems across multiple campus buildings. The project also offers alternates for additional roof replacement and generator replacement. Drawings cover demolition plans, renovation plans, mechanical, electrical, structural, phasing and existing conditions. Specifications address asbestos abatement, lead remediation and other hazardous materials handling requirements. The related solicitation is for design-build services for the project under solicitation number 36C25722R0010.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 36C25722R0010 0001.docx | DOCX document | |
| Answers to Questions 36C25722R0010 DB Replace Boilers.pdf | ||
| VA NOTICE OF LIMITATIONS ON SUBCONTRACTING REQUIREMENT.pdf | ||
| Past Performance Questionnaire.pdf | ||
| Mech 035 - Pages 1-3.pdf | ||
| Mech 035 - Pages 4-6.pdf | ||
| OSHA - EMR requirement.pdf | ||
| BP-3-Boiler-steam.pdf | ||
| BP-1-Boiler-fueloil.pdf | ||
| AS ST Series Sheets.pdf | ||
| AD AE Series Sheets.pdf | ||
| Elect 035.pdf | ||
| BP-4-Water-Treatment.pdf | ||
| 36C25722R0010_1.docx | DOCX document | |
| Mech 035 - Pages 7-12.pdf | ||
| Phasing sheets.pdf | ||
| Struct 035.pdf | ||
| SELF-PERFORMED CALCULATIONS.pdf | ||
| Mech 035 - Pages 8-19.pdf | ||
| BP-2-Boilers-natgasandpropane.pdf | ||
| 20-09 035 Narrative 02 1r1 Phasing Narrative.pdf | ||
| 20-09 035 Narrative 06 1r1 Civil-LS Design Narrative.pdf | ||
| 20-09 035 Narrative 13 1r1 Specs TOC 000110 035 21-06-30.pdf |
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 Fax: 402.291.9193
AH. INZ
Shaffer & Stevens 9910 North 48th Street
Omaha, Nebraska68152
Phone: 402.455.7698 Fax: 402.455.7597
504-18-119
IMEG Corp.
14755 Preston Rd., Suite 845
Dallas, TX 75254
Phone:(972) 239-6100
15% Design Submission 07/14/2020
20% Design Submission
30% Design Submission
35%/SD1 Schematic Design Submission - Request for Proposal
AMI Environmental Inc
8802 S 135th Street
Omaha, NE 68138
Phone:(402) 397-5001
08/14/2020
FOR REFERENCE
ONLY NOT FOR
CONSTRUCTION
09/08/2020
11/17/2020
C
L H
D C
\H o m e \t fi e s e lm a n
\R e v it
M o d e ls \R
-5
-1 -1
B o ile rs tf ie s e lm a n A
G Y
.r v t
/1 /2
:1
:2
A
M
G-001
COVER SHEET
xxx AHTNovember 17, 2020
Replace Boilers & PipingSD-1 35% SUBMITTAL -
REQUEST FOR PROPOSAL
Thomas E. Creek VAMC-Amarillo,TX
EXTERIOR PERSPECTIVE - BUILDINGS 11-16-19
REPLACE BOILERS & PIPING
THOMAS E. CREEK AMARILLO VA HEALTH CARE SYSTEM
VA PROJECT NO. 504-18-119
CLH PROJECT NO. 2020-09
6010 Amarillo Blvd. West, Amarillo, TX 79106-1990
BOILER PLANT -
BLDG. 11
WATER
TREATMENT -
BLDG. 19
COMMUNITY
LIVING CENTER
(CLC) - BLDG. 29
MAIN
HOSPITAL -
BLDG. 28
ORIGINAL
HOSPITAL -
BLDG. 1
SERVICES /
DIETARY -
BLDG. 4
W E S T
A M
A R
IL
LO
B
LV
D
(H
IS
T.
U
S H
W Y . 6
6)
S.W. 9TH AVENUE
MAIN ENTRANCE
NORTH ENTRANCE
B E
L L
S T
R E
E T
N N
TRUE
NORTH
PLAN
NORTH
12" = 1'-0"
PROJECT LOCATION PLAN
MAINTENANCE
STORAGE -
BLDG. 16
HENRID
ON
W . E
DM
AN
N. EDM
AN
S. EDM
AN
E. W
ALKER
W . W
A
LK
E R
NOT TO SCALE
PARKING LOT 'K'
PARKING LOT 'J'
REQUEST FOR PROPOSAL
TO DESIGN BUILD
Revisions: Date:
ABBREVIATIONS
DET, DTL
DIAMETER
DIMENSION
DAMPER
DOWN
DISTRIBUTION PANEL
DOWNSPOUT, STORM DRAINAGE STRUCTURE
DOMESTIC WATER
DRAWING
EACH
EACH FACE, EXHAUST FAN
EXHAUST GRILLE
ELEVATION
ELECTRIC, ELECTRICAL CLOSET
EMER
EQ
EQUIP
EACH WAY
ELECTRIC WATER COOLER
EXH
EXIST
EXP
EXPANSION JOINT
EXPANSION JOINT
HEIGHT, HUMIDIFIER
HB
HANDICAPPED
HDW
HORIZ
HR
NA
NEC
NEUT
NIC
NOM
NTS
OA
OC
OD
OPNG
OPP
OH, OVHD
FRAME
FTG
T
T&B
TEL
TEMP
TERM
3/C
3/P
3 WAY
TO
TRANS
TS
TV
TW
TYP
WA
UH
V
VA
VAC
VCT
VENT
VERT
VEST
VS
VTR
VWC
W
W
W/
W/O
WC
WD
WP
WS
WT
WWF
SG
SAN
SCH
SD
SECT
SH
1 PH
SL
SP
SPDT
SPEC
SPST
SQ
SR
SS
ST
STA
STD
STL
SUP
SUSP
SV
SW
SWBD
SWGR
SIM
M
MAS
MATL
MAX
MECH
MET/MTL
MH
MIN
MISC
MM
MTD
MTG
MWP
MULL
KO
KVA
KW
L
LT
LAV
INT
INSUL
INV
JB
JC
JCT
JT
FXTR
GA
GALV
GFI
GL
GWB
GYP
C
C
CAPACITY
CENTER TO CENTER
CEILING DIFFUSER
CEM
CAST IRON, COURTYARD INLET
CHILLER
CAST IRON PIPE
CIRCULATING
CONTROL JOINT
CIRCUIT
CENTERLINE
CEILING
CLEAR
CORRUGATED METAL PIPE
CORRUGATED METAL PIPE ARCH
CONCRETE MASONRY UNITS
CONDENSATE
CLEANOUT
COLUMN
COMMUNICATION
CONCRETE
CONDUCTOR
CONNECTION
CONSTRUCTION
CONTINUOUS
CONVERTER
NONREINFORCED CONCRETE PIPE
CONDUIT
CERAMIC TILE, CURRENT TRANSFORMER,
COOLING TOWER
CENTER, COOLING TOWER RETURN
COOLING TOWER SUPPLY
COLD WATER
CARPET
CONCRETE SEALER/SURFACE
BOARD
BUILDING
BLK
BEAM
BOTTOM
BEARING
BASEMENT
ACOUSTIC
ADJUSTABLE
ABOVE FINISHED FLOOR
ALTERNATE
AIR HANDLING UNIT
ANCHOR BOLT, AUGER BORING
AL
APPROXIMATE
ARCH
AUTOMATIC TRANSFER SWITCH
FA
FLOOR DRAIN, FIRE DAMPER
FOUNDATION
FEEDER
FIRE EXTINGUISHER
FINISHED FLOOR ELEVATION
FIG
FIN
FLOOR, FLASHING, FLOW LINE
FLUOR
P
PB
PIV
PL
PLYWD
PNL
PNT
CHAIR OR CRASH RAIL
CORNER GUARD
FIRE EXTINGUISHER CABINET
OF
WG
ALC
CUBICAL CURTAIN TRACK
CLEAN
ACOUSTIC TILE
L
EPDM ROOF MEMBRANE
HSKP
NEG
STRUC
R
RA
RAD
RVB
RCP
RECP
REINF
REG
REQD
REV
RF
RHC
RM
RPM
RVT
PRELIM
PRIM
PT
PTN
PVMT
PVC
PVC
AB
ACT
ACST
ADJ
AFF
AHU
ALT
ALUMINUM
ALCOVE
APPROX
ARCHITECTURAL
ATS
BD
BLDG
BLOCK
BM
BOT
BRG
BSMT
CELSIUS
CAP
CC
CD
CCT
CEMENT
CG
CH
CI
CIP
CIR
CJ
CKT
CLN
CLG
CLR
CMP
CMPA
CMU
CND,C
CNDS
CO
COL
COMM
CONC
COND
CONN
CONST
CONT
CONV
CP
CR
CS
CT
CT
CTR
CTS
CW
CPT
DETAIL
DIA
DIM
DMPR
DN
DP
DS
DW
DWG
EA
EF
EG
EJ
ELEV
ELEC
EMERGENCY
EPDM
EQUAL
EQUIPMENT
EW
EWC
EXHAUST
EXISTING
EXPANSION, EXPOSED
EXP JT
FIRE ALARM
FD
FDN
FDR
FE
FEC
FFE
FIGURE
FINISH
FL
FLUORESCENT
FRAME
FOOTING
FIXTURE
GAGE
GALVANIZED
GROUND FAULT INTERRUPT
GLASS
GYPSUM WALL BOARD
GYPSUM
HGT, H
HOSE BIBB
HC
HARDWARE
HORIZONTAL
HOUR, HAND RAIL
HOUSEKEEPING
INTERIOR
INSULATION, INSULATED
INVERT
JUNCTION BOX
JANITOR CLOSET
JUNCTION
JOINT
KNOCK OUT
KILOVOLT-AMPERE
KILOWATT
LOUVER, LENGTH, LENGTH OF CURVE
LIGHT
LAVATORY VERTICAL
METER, MEGA
MASONRY
MATERIAL
MAXIMUM
MECHANICAL
METAL
MANHOLE
MINIMUM, MINUTE
MISCELLANEOUS
MILLIMETER
MOUNTED
MOUNTING
MEMBRANE WATERPROOFING
MULLION
NOT APPLICABLE
NATIONAL ELECTRIC CODE
NEGATIVE
NEUTRAL
NOT IN CONTRACT
NOMINAL
NOT TO SCALE
OUTSIDE AIR
ON CENTER
OUTSIDE DIAMETER
OVERFLOW DRAIN
OPENING
OPPOSITE
PIPE, POLE
OVERHEAD
PULL BOX
POST INDICATOR VALVE
PLATE
PLYWOOD
PANEL
PAINT
PRELIMINARY
PRIMARY
POINT, POINT OF TANGENT
PARTITION
POINT OF VERTICAL CURVE
POLY VINYL CHLORIDE
PAVEMENT
RADIUS, RISER, RUBBER SHEATH
RETURN AIR
RADIUS
RESILIENT VINYL BASE
RCP
RECEPTACLE
REINFORCEMENT
REGULATOR, REGISTER
REQUIRED
REVISION
ROOF, RETURN FAN
REHEAT COIL
ROOM
REVOLUTIONS PER MINUTE
RESILIENT VINYL TILE
SANITARY SEWER
SCHEDULE
SPLITTER DAMPER, STORM DRAIN
SECTION
SUPPLY GRILLE
SHEET
SIMILAR
SINGLE PHASE
SLOPE
STATIC PRESSURE, SINGLE POLE
SINGLE POLE, DOUBLE THROW
SPECIFICATION
SINGLE POLE, SINGLE THROW
SQUARE
SUPPLY REGISTER
SANITARY SEWER
STEAM, SINGLE THROW, STREET, STAFF
STATION
STANDARD
STEEL
STRUCTURAL
SUPPORT
SUSPENDED
SHEET VINYL
SWITCH, SIDEWALK
SWITCHBOARD
SWITCHGEAR
TILE,TOP,TANGENT
TOP AND BOTTOM
TELEPHONE
TEMPERATURE, TEMPORARY
TERMINAL
THREE CONDUCTOR
THREE POLE
THREE WAY
TOP OF
TRANSITION
TOP OF STEEL, TOP OF STONE, TOP OF SLAB
TELEVISION
TOP OF WALL
TYPICAL
UNIT HEATER
VENT,VOLT,VALVE
VOLT AMPRE
VACUUM
VINYL COMPOSITION TILE
VENTILATING
VERTICAL
VESTIBULE
VENT STACK
VENT THRU ROOF
VINYL WALL COVERING
WIDTH,WASTE,WATER,WATT,WEST, WIRE,
WATER LINE STRUCTURE
WATT
WITH
WITHOUT
WATER CLOSET, WHEEL CHAIR
WIDTH, WINDOW DIMENSION
WALL GUARD
WATERPROOF, WEATHERPROOF
WASTE STACK, WATER SURFACE, WATERSTOP
WEIGHT
WELDED WIRE FABRIC
TA TOILET ACCESSORIES
WDW WINDOW
ARCHITECTURAL
SYMBOLS
A101
DETAIL NUMBER
COLUMN NUMBER /
GRID LINE
SHEET NUMBER
ARCHITECTURAL
SECTION
WINDOW TYPE
1 Ref
R e f
1 Ref
R e f
ARCHITECTURAL
ELEVATION
X
X-XXX
DETAIL NUMBER
SHEET NUMBER
CENTER LINE
DIMENSION LINE
DOOR NUMBER
SYMBOL
x'- x"
EXISTING TO REMAIN
NEW CONSTRUCTION
EXISTING TO BE
REMOVED
EXISTING TO REMAIN
1i
KEYNOTE -
RENOVATION
WALL / PARTITION TYPE
KEYNOTE - DEMOLITION
PLAN
X
X
X
NOTE: NOT ALL SYMBOLS USED
ROOM NAME
ROOM NAME
ROOM NUMBER
XX
X-XXX
SHEET DETAIL IS
DRAWN ON
DETAIL NUMBER
XX
X-XXX ARCHITECTURAL
ELEVATION - EXTERIOR
XX SP XX SP DESIGN SF
PROGRAM SF
ACT-X
X'-X" AFF
CEILING CODE
CEILING HEIGHT,
ABOVE FINISH FLOOR
1. SCHEMATIC DEISGN DRAWINGS HAVE BEEN PREPARED FOR
USE OF DESIGN-BUILD OFFERORS TO ILLUSTRATE DESIGN
CONCEPTS AND SCOPE OF WORK IN CONJUNCTION WITH
ADDITIONAL REQUEST FOR PROPOSAL (RFP) DOCUMENTS.
THE DESIGN-BUILD TEAM/OFFEROR SHALL REVIEW ALL
DOCUMENTS PROVIDED AS PART OF THIS RFP SOLICITATION
AND PREPARE THEIR PROPOSAL AS REQUIRED IN SECTION 00
11 21 - REQUEST FOR PROPOSAL TO DESIGN-BUILD.
2. REFER TO SPECIFICATION SECTIONS 00 11 21 AND 01 00 00
FOR DESCRIPTION OF ITEMS TO BE INCLUDED IN THE BASE
BID AND LISTING OF ADD ALTERNATES.
3. DESIGN-BUILD OFFERORS, CONSULTANTS,
SUBCONTRACTORS, MANUFACTURERS AND SUPPLIERS ARE
REQUIRED TO ATTEND A PRE-PROPOSAL CONFERENCE AND
WALK-THROUGH TO BE SCHEDULED BY THE OWNER. REFER
TO THE RFP SOLICITATION AND SECTION 00 11 21.A4 FOR
DATE, TIME AND LOCATION.
4. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS PRIOR TO CONSTRUCTION.
5. ALL NEW CONSTRUCTION IS INDICATED BOLD OR FULL TONE.
6. ALL EXISTING CONSTRUCTION, CABINETWORK, EQUIPMENT,
ETC. TO REMAIN IS INDICATED LIGHT OR HALF TONE.
7. ALL METAL STUD AND GYPSUM WALLBOARD PARTITIONS ARE
DIMENSIONED TO THE OUTSIDE FACE AND TO COLUMN GRID
UNLESS OTHERWISE NOTED.
8. WHEN WALL PARTITIONS OF DIFFERENT FIRE RATING
INTERSECT, THE HIGHEST RATED PARTITION TAKES
PRECEDENT. MAINTAIN RATING BEHIND FIRE EXTINGUISHER
CABINETS, ETC.
9. ALL FURNITURE SHOWN HALF TONE WILL BE OWNER
FURNISHED AND OWNER INSTALLED.
10. ALL EXISTING TO REMAIN CEILING AND WALL GRILLES,
DIFFUSERS AND LIGHTS ETC. ARE TO BE CLEANED PRIOR TO
PROJECT COMPLETION AND ACCEPTANCE BY THE OWNER.
11. VERIFY THAT THE EXISTING WALLS REQUIRING FIRE RATING
ARE MAINTAINED, REPAIRED AND EXTENDED TO STRUCTURE.
12. ALL CORRIDOR WALLS ARE REQUIRED TO BE SMOKE TIGHT,
WHETHER THEY ARE FIRE RATED OR NOT. REPAIR AND
EXTEND AT LEAST THE CORRIDOR SIDE OF NON-FIRE RATED
CORRIDOR WALLS TO STRUCTURE, UNLESS NOTED
OTHERWISE.
13. TEMPORARY OPENING SUPORTS AND ENCLOSURES SHALL
BE DESINGED AND INSTALLED BY THE DESIGN-BUILD
OFFEROR SO AS TO PROVIDE A WEATHERTIGHT ENCLOUSRE
FOR THE BUILDING. REVIEW AND APPROVAL OF OPENING
SUPPORTS AND ENCLOSURE DESIGN IS REQUIRED BY THE
VA'S COR PRIOR TO BEGINNING OF WORK.
14. PROTECTION OF EXISTING STRUCTURES ADJACENT TO
TEMPORARY OPENINGS SHALL BE REVIEWED WITH AND
APPROVED BY THE VA'S COR PRIOR TO BEGINNING OF
WORK.
15. PHASING AND SCHEDULING OF UTILITY SHUT-DOWNS OR
OTHER DISTURBANCES IN OPERATION OF THE FACILTY SHALL
BE WITH THE INPUT AND APPROVAL OF THE VA'S COR AND
CAMPUS ENGINEERING.
16. REFER TO SPECIFICATIONS FOR REQUIREMENTS RELATED
TO THE USE AND OPERATION OF TEMPORARY BOILERS,
INCLUDING SAFETY TRAINING, INSPECTIONS AND
MAINTENANCE BY THE CONTRACTOR.
17. COMPLY WITH REQUIREMENTS OF THE LATEST VA PHYSICAL
SECURITY & RESILIENCY DESIGN MANUAL FOR ITEMS
DISTURBED BY THE WORK, INCLUDING PROVISION OF
PROTECTIVE FILMS, LAMINATED GLAZING AND USE OF
STRUCTURAL SILICONE, ANCHORAGES OF WINDOW FRAMES,
AND RELATED ITEMS AT WINDOWS.
18. SEE ARCH RA-SERIES, MECH M-SERIES FLOOR PLANS &
MECH RM-SERIES EXISTING CONDITIONS SHEETS FOR
PHOTOS OF EXISTING CONDITIONS.
GENERAL NOTES:
1. THE CONTRACTOR SHALL INSPECT THE SITE, STUDY EXISTING CONDITIONS,
REVIEW DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PROVIDED AS
PART OF THE CONSTRUCTION DOCUMENTS. CONTRACTOR SHALL ADJUST FOR
ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE GOV'T.
2. CONTRACTOR SHALL TAKE ALL MEASUREMENTS FOR THE WORK AND BE
RESPONSIBLE FOR SAME. COORDINATE THE WORK AND SHOP DRAWINGS WITH
ALL OTHER TRADES AFFECTED AND MAKE ANY NECESSARY OFFSETS TO
CONCEAL PIPING AND DUCTWORK AND TO CLEAR EQUIPMENT, STRUCTURAL
MEMBERS AND OTHER OBSTRUCTIONS.
3. ALL UTILITIES AND SERVICES SHALL BE KEPT IN CONTINUOUS OPERATION
UNLESS WRITTEN PERMISSION IS OTHERWISE GRANTED BY THE THE GOV'T..
CONTRACTOR MUST CONTACT VA'S COR PRIOR TO ANY SHUTDOWNS.
4. TEMPORARY ALTERATIONS AND CONNECTIONS REQUIRED BY THIS CONTRACT
SHALL BE MADE SO THAT ALL BUILDING SERVICES ARE MAINTAINED WITH
MINIMUM INTERRUPTION.
5. SCHEDULE ALL ELECTRICAL/MECHANICAL OUTAGES 14 DAYS IN ADVANCE WITH
THE GOV'T. UNLESS OTHERWISE DIRECTED IN THE SPECIFICATIONS.
SPECIFICATIONS REQUIREMENTS WILL SUPERSEDE.
6. PROTECT ALL WORK, MATERIALS AND EQUIPMENT DESIGNATED TO REMAIN. CAP
OR PLUG TEMPORARY OPENINGS. DELIVER ALL WORK TO THE THE GOV'T. IN
CLEAN AND IN GOOD CONDITION.
7. WHEN DEMOLITION IS COMPLETE, NOTIFY ARCHITECT AND THE GOV'T. FOR A
SCHEDULED MEETING TO REVIEW EXISTING CONDITIONS AND ANY CONCERNS
REGARDING NEW WORK.
8. CUTTING AND PATCHING OF EXISTING WALLS, FLOORS OR CEILINGS REQUIRED
BY NEW WORK SHALL BE INCLUDED AS WORK PROVIDED UNDER THIS CONTRACT.
9. CUTTING SHALL BE DONE WITH CARE SO AS NOT TO DAMAGE EXISTING
EQUIPMENT, CONNECTIONS, CONTROLS, ETC. DAMAGE CAUSED BY SUCH
CUTTING SHALL BE REPLACED OR REPAIRED TO ORIGINAL CONDITION BY
CONTRACTOR AT NO COST TO THE THE GOV'T., UNLESS UNFORESEEN EXISTING
CONDITIONS ARE DISCOVERED AND THE GOV'T./ARCHITECT ARE NOTIFIED.
10. ALL OCCUPIED WORK AREAS, BUILDING CORRIDORS AND EXTERIOR AREAS
SHALL BE KEPT CLEAR OF DEBRIS.
11. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, OF THE BEST QUALITY AND
FREE FROM DEFECTS.
12. MANUFACTURER AND MODEL NUMBERS SPECIFIED ESTABLISH THE TYPE AND
QUALITY REQUIRED, UNLESS OTHERWISE NOTED.
13. ALL WORK SHALL COMPLY WITH APPLICABLE REGULATIONS, CODES AND
ORDINANCES.
14. THE CONTRACTOR SHALL PERFORM ALL TESTS AS SPECIFIED OR AS NECESSARY
TO DEMONSTRATE A COMPLETE AND SATISFACTORY INSTALLATION.
15. ALL EXPOSED PENETRATIONS MADE THROUGH EXISTING ROOFS, FLOORS, AND
WALLS SHALL BE PATCHED WITH LIKE MATERIALS TO MATCH THE SURROUNDING
AREAS, AND FILLED AS CLOSE AS POSSIBLE TO THE NEW PIPING OR DUCTWORK.
16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING AND REPLACING ANY
DAMAGE TO EXISTING MATERIALS RESULTING FROM WORK UNDER THIS
CONTRACT AND SHALL RESTORE SUCH TO ITS ORIGINAL CONDITION OR BETTER
WITH NEW MATERIALS TO MATCH.
17. INSTALL THE SPECIFIED FIRE STOPPING (SLEEVES, WRAP, CONDUIT, ETC.) AT
RATED CONSTRUCTION (NEW OR EXISTING) OR SMOKE PARTITIONS:
A. REPLACE FIRE STOPPING AT ALL PENETRATIONS WHERE NEW
DEVICES/LINES USE EXISTING PENETRATIONS OF RATED BARRIERS.
B. REPLACE FIRE STOPPING AT ALL EXISTING PENETRATIONS OF RATED
BARRIERS WHERE EXISTING LINES HAVE BEEN MODIFIED OR RELOCATED.
C. FIRE STOP ALL NEWLY CREATED PENETRATIONS WHERE NEW
DEVICES/LINES PENETRATE EXISTING FLOORS, CEILINGS AND OTHER
RATED BARRIERS.
D. FIRE STOP ALL NEW PENETRATIONS WHERE NEW DEVICES/LINES
PENETRATE THROUGH NEWLY CONSTRUCTED RATED BARRIERS OR
SMOKE PARTITIONS.
E. USE ONLY APPROVED FIRE CAULKING AND FIRE STOPPING (SEE
SPECIFICATIONS).
18. ALL METAL STUD AND GYPSUM WALLBOARD PARTITIONS ARE DIMENSIONED TO
THE OUTSIDE FINISH FACE OF WALL AND TO THE COLUMN GRID UNLESS
OTHERWISE NOTED.
19. ALL GYPSUM BOARD SHALL BE TYPE 'X' FIRE CODE GYPSUM BOARD AND SHALL
BE MOLD AND MOISTURE RESISTANT.
20. PROVIDE WOOD BLOCKING OR 16 GA. SHEET METAL BACKING PLATES IN ALL
WALLS TO RECEIVE WALL HUNG ACCESSORIES, SUCH AS EQUIPMENT, GRAB
BARS, MILLWORK, COAT HOOKS, AND DOOR STOPS, ETC. IF WOOD BLOCKING IS
USED, PROVIDE AS FIRE-RESISTANT.
21. ALL ITEMS AND DEVICES, SUCH AS COVER PLATES, SWITCH PLATES,
CONVENIENCE OUTLETS, DOOR STOPS, AND OTHER FINISH HARDWARE, ETC.
SHALL BE REMOVED AND REINSTALLED AS PART OF THE REFINISHING OF
EXISTING WALLS INDICATED TO REMAIN.
22. THE CONTRACTOR SHALL WORK WITH THE CONDITIONS AS THEY EXIST AT THE
SITE. ALL ABOVE CEILING CONDITIONS SHALL BE REVIEWED, AND MODIFICATIONS
IDENTIFIED, COORDINATED, AND INCORPORATED INTO THE SHOP DRAWING
PROCESS. COORDINATE ALL ABOVE EILING WORK TO ENSURE A COMPLETE AND
OPERATIONAL SYSTEM AT NO ADDITIONAL COST TO THE GOV'T.. COORDINATION
SHALL INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING:
A. THE GOV'T.'S EQUIPMENT REQUIREMENTS.
B. THE CEILING SUPPORT SYSTEM.
C. THE MECHANICAL DUCTWORK SYSTEM.
D. THE LIGHTING FIXTURES.
E. ELECTRICAL WIRING AND CONDUIT SYSTEMS.
F. THE PLUMBING AND PIPING SYSTEMS.
G. FIRE PROTECTION SYSTEMS
H. THE COMMUNICATIONS AND SPECIAL SYSTEMS.
23. ALL CONTRACTORS ARE RESPONSIBLE FOR REVIEWING ENTIRE SET OF
DOCUMENTS TO DETERMINE THEIR FULL SCOPE OF WORK. CONTRACTOR SHALL
NOT BE ALLOWED EXTRA COSTS DUE TO FAILURE TO REVIEW ENTIRE SET OF
DOCUMENTS.
24. ALL NEW STUD WALLS AND GYPSUM BOARD SHALL EXTEND TO STRUCTURE
UNLESS NOTED OTHERWISE.
25. WHEN ALTERING THE BUILDING, IF STRUCTURAL INTEGRITY APPEARS TO BE IN
QUESTION CONTRACTOR SHALL NOTIFY THE GOV'T. AND ARCHITECT
IMMEDIATELY.
26. ALL NEW CONSTRUCTION IS INDICATED BOLD OR FULL TONE.
27. WHEN WALL PARTITIONS OF DIFFERENT FIRE RATING INTERSECT, THE HIGHEST
RATED PARTITION TAKES PRECEDENT. MAINTAIN RATING BEHIND RECESSED
AREAS IN WALLS.
28. ALL CORRIDOR WALLS WITHIN BUILDINGS ARE REQUIRED TO BE SMOKE TIGHT,
WHETHER THEY ARE FIRE RATED OR NOT. REPAIR AND EXTEND AT LEAST THE
CORRIDOR SIDE OF NON-RATED CORRIDOR WALLS TO STRUCTURE, UNLESS
NOTED OTHERWISE.
29. COORDINATE CONSTRUCTION REQUIREMENTS WITH CIVIL, STRUCTURAL,
MECHANICAL, FIRE PROTECTION, PLUMBING AND ELECTRICAL DRAWINGS.
30. AFTER DEMOLITION AND NEW CONSTRUCTION, REPAIR ALL FINISHED SURFACES
ON EXISTING ITEMS TO REMAIN AFFECTED BY WORK TO LIKE-NEW CONDITION.
31. ALL FINISHED SURFACES ON NEW WALLS, ETC. INFILLING OR EXTENDING
EXISTING ITEMS SHALL BE INSTALLED SO NEW FINISHED SURFACES ALIGN WITH
EXISTING.
32. FURNITURE SHOWN IS N.I.C. UNLESS NOTED OTHERWISE. EQUIPMENT SHALL BE
PROVIDED BY THE GOV'T. UNLESS NOTED OTHERWISE AND INSTALLED BY THE
CONTRACTOR AS SCHEDULED. DISCONNECTION, RELOCATION, AND
RECONNECTION OF EXISTING EQUIPMENT IS THE RESPONSIBILITY OF THE
CONTRACTOR.
33. CONTRACTOR SHALL VERIFY LOCATION OF ANY EXISTING CONDUITS, PIPING AND
SUPPORTS ABOVE AND BELOW THE EXISTING ROOF PRIOR TO START OF
DRILLING OR CUTTING ANY HOLES, IF NECESSARY, IN THE ROOF DECK. POWER
INTERRUPTION SHALL BE AVOIDED.
GENERAL
ARCHITECTURAL
NOTES:
1. DASHED BOLD LINES INDICATE EXTEND OF DEMOLITION
INCLUDING THE FOLLOWING:
A. INTERIOR PARTITIONS (REMOVED TO STRUCTURE
B. CEILINGS, INCLUDING CEILING SUSPENSION SYSTEM,
MISC. STEEL SUPPORTS FOR SUSPENDED
EQUIPMENT, SUSPENDED EQUIPMENT, LIGHT
FIXTURES, DIFFUSERS AND GRILLES ETC.
C. FLOOR FINISHES (TO CONCRETE) INCLUDING CARPET,
RVT, SHEET VINYL, CERAMIC TILE, QUARRY TILE,
BRICK PAVERS, ETC.
D. DOORS AND FRAMES UNLESS NOTED OTHERWISE IN
DOOR SCHEDULE
E. WINDOW GLAZING AND FRAMES UNLESS NOTED
OTHERWISE
F. BRICK AND BACK-UP WALL SYSTEM
G. CABINETWORK, SHELVING, BASES
H. TOILET PARTITIONS AND ACCESSORIES
I. TACK BOARDS, MARKER BOARDS, PEGBOARDS,
DISPLAY BOARDS
J. EQUIPMENT ITEMS
K. PLUMBING FIXTURES
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS.
2. ALL LIGHT OR HALFTONE LINES INDICATE EXISTING TO
REMAIN.
3. SEE SPECIFICATIONS SECTION 02 41 00 FOR CUTTING,
PATCHING AND DEMOLITION.
4. SEE STRUCTURAL, MECHANICAL AND ELECTRICAL PLANS
FOR EXTENTS OF WORK AT OR ABOVE EXSTING
CEILINGS. PATCH AND REFINISH CEILINGS DISTURBED BY
DEMOLITION AND NEW CONSTRUCTION TO MATCH
ADJACENT FINISHES UNLESS NOTED OTHERWISE.
5. EXISTING FLOORS WHICH ARE DISTURBED BY
DEMOLTION AND NEW CONSTRUCTION ARE TO BE
PATCHED AND REFINISHED TO MATCH ADJACENT
EXISTING FINISHES UNLESS NOTED OTHERWISE.
6. IN ARES WHERE EXSITING WALL FINISHES ARE
DISTURBED BY DEMOLITION AND NEW CONSTRUCTION,
PATCH AND REFINISH TO MATCH ADJACENT EXISTING
FINISHES. REMOVE EXISTING WALL FINISHES (I.E.
RESILIENT WALL BASE, CERAMIC TILE, ETC.) AND
REPLACE WITH NEW MATERIAL TO MATCH EXISTING.
7. CONTRACTOR TO VERIFY ALL WALL CONSTRUCTION &
FINISHES NOTED FOR REMOVAL. TAKE INTO ACCOUNT
ANY DISCREPANCY AND MAKE PROPER ADJUSTMENT TO
ACCOMPLISH REQUIRED CONSTRUCTION & FINISHES. IF
STRUCTURAL INTEGRITY IS VIOLATED, CONTACT
ARCHITECT. COORDINATE PHASING WITH OWNER.
8. COORDINATE REMOVAL OF FURNITURE AND EXISTING
EQUIPMENT WITH OWNER.
9. SAW CUT EDGES OF EXISTING FLOOR SLAB FOR
REMOVAL AND INSTALLATION OF UNDERFLOOR ITEMS
SUCH AS FOOTINGS, FOUNDATIONS AND UTILITIES.
REFER TO STRUCTURAL, MECHANICAL AND ELECTRICAL
DRAWINGS.
10. REMOVE FURRING OR GWB ONLY WHERE REQUIRED TO
COMPLETE CONSTRUCTION. PATCH AND MATCH WALLS
AS REQUIRED TO COMPLETE AND MATCH EXISTING
CONDITIONS, UNLESS AN ALTERNATIVE MATERIAL AND
FINISH IS INDICATED.
11. REMOVE CEILINGS ONLY AS REQUIRED FOR NEW
CONSTRUCTION. REINSTALL, REPLACE OR PATCH AS
REQUIRED.
GENERAL
DEMOLITION
NOTES:
1. CONTRACTOR SHALL COMPLY WITH THE MOST-CURRENT
VERSION OF OSHA'S PUBLICATION 3142-12R "LEAD IN
CONSTRUCTION" (29 CFR 1926.62) FOR CONSTRUCTION
ACTIVITIES THAT DISTURB LEAD-BASED PAINTED SURFACES,
PAINT CONTAINING DETECTABLE LEVELS OF LEAD OR OTHER
MATERIALS CONTAINING LEAD..
2. CONTACT THE COR TO OBTAIN MOST-CURRENT COPIES OF
ASBESTOS AND LEAD BASED PAINT (LBP) REPORTS. REFER TO
DIVISION 2 IN THE SPECIFICATIONS FOR ASBESTOS ABATEMENT
AND LEAD BASED PAINT REMOVAL AND/OR ENCAPSULATION
SPECIFICATIONS.
3. HAZARDOUS MATERIALS DISCLOSED IN THE ACM AND LBP
REPORTS MAY NOT BE A FULL ACCOUNTING OF SUCH
MATERIALS IN THE AREA OF THE FACILITY IN QUESTION. REFER
TO THE VA'S ABATEMENT SPECIFICATIONS FOR HANDLING OF
MATERIALS THAT WERE NOT DIRECTLY OBSERVED, BUT
SHOULD BE EXPECTED BY THE ABATEMENT CONTRACTOR.
4. CONTRACTOR TO VERIFY THE ABSENCE OF ASBESTOS
CONTAINING MATERIALS (ACM) PRIOR TO ANY DEMOLITION.
5. IF THE CONTRACTOR ENCOUNTERS MATERIAL THAT COULD BE
HAZARDOUS, THE CONTRACTOR SHALL STOP WORK AND
NOTIFY THE GOVT. IMMEDIATELY FOR DIRECTION.
6. ALL CONTRACTORS' PERSONNEL IN AREAS NEAR DISTURBANCE
OR ABATEMENT OF HAZARDOUS MATERIALS MUST MUST BE
NOTIFIED OF ACTIVITIES.
7. ASBESTOS AND LEAD-BASED PAINT ABATEMENT, IF REQUIRED,
SHALL BE CONDUCTED IN ACCORDANCE WITH VA
SPECIFICATIONS AND ALL APPLICABLE REGULATIONS.
8. ABATEMENT CONTRACTORS SHALL SCHEDULE WORK IN
GENERAL ACCORDANCE WITH THE PROJECT'S PHASING
STRATEGY.
1. MAINTAIN FIRE RATED CONSTRUCTION AT WALL
PENETRATIONS - CONSTRUCTION IS TO CONFORM TO
MANUFACTURER'S FIRE RATED / TEST ASSEMBLIES.
2. FIRE CAULK ALL SLEEVES AND PENETRATIONS AT FIRE WALLS /
PARTITIONS AND FLOORS. CONFORM WITH THE TESTED /
SUBMITTED FIRE RATED ASSEMBLY. USE RED FIRE CAULK AND
LABEL WALL WITH U.L. DESIGN NUMBER. FIRE RATED WALLS
SHOWN ON PLAN.
3. PATCH AND REPAIR ALL EXISTING FIREPROOFING ON EXISTING
STRUCTURAL MEMBERS, INCLUDING THAT WHICH IS
UNCOVERED NEEDING REPAIR AND THAT WHICH IS DISTURBED
DURING CONSTRUCTION.
4. PATCH AND REPAIR ALL EXISTING FIRE CAULKING AT EXISTING
RATED WALLS WHICH IS UNCOVERED NEEDING REPAIR AND
THAT WHICH IS DISTURBED DURING CONSTRUCTION. RE-
LABEL EXISTING WALL IF NECESSARY.
HAZARDOUS MATERIALS
FIRE PROOFING
GENERAL NOTES
MATERIAL SYMBOLS
EARTH
CAST-IN-PLACE CONCRETE /
PRECAST CONCRETE
CONCRETE MASONRY
STEEL
CONTINUOUS WOOD FRAMING
WOOD BLOCKING
FIBROUS INSULATION
GYPSUM BOARD
BRICK MASONRY
RIGID INSULATION
ROOF INSULATION
ALUMINUM
1. PHASE I - TEMPORARY CONDITIONS AND DEMOLITION -
TEMPORARY BOILERS, BOILER REMOVAL & BOILER HEADER
REVISIONS.
2. PHASE II - INSTALLATION OF NEW EQUIPMENT - NEW
BOILERS, DEAERATOR TANK AND RELATED EQUIPMENT.
PHASE ALSO INCLUDES:
A. STEAM TUNNELS - REPLACEMENT OF CONDENSATE
LINES IN PIPE TUNNELS;
B. BLDG. 11 - REPAIR (BASE BID) AND/OR
REPLACEMENT OF ROOFING (ADD ALTERNATE);
C. BLDG. 11 - REPAIR OF CRACKS AND JOINTS AT
EXTERIOR WALLS;
D. BLDG. 11 - REPLACEMENT OF GENERATOR (ADD
ALTERNATE);
E. BLDGS. 1, 4, 28 & 29 - REPLACEMENT OF HEAT
EXCHANGER WATER HEATERS;
F. BLDGS. 1, 4, 28 & 29 - MODERNIZATION OF OF STEAM
DISTRIBUTION AND CONDENSATE PIPING;
G. BLDGS. 1 & 4 - REPLACEMENT OF PRESSURE
REDUCTION VALVES AND CONDENSATE RETURN
LINES;
H. BLDGS. 1, 4, 28 & 29 - REPLACEMENT OF DEFECTIVE
STEAM TRAPS.
3. REFER TO SHEET 11-PH101, SPECIFICATION SECTIONS 00 11
21-REQUST FOR PROPOSAL TO DESIGN BUILD AND 01 00 00-
GENERAL REQUIREMENTS FOR ADDITIONAL PHASING
INFORMATION.
4. PHASING OF WORK TO BE COORDINATED WITH AVAHCS'
HEATING AND COOLING SEASONS TO MINIMIZE
DISRUPTIONS TO OPERATION OF THE FACILITY.
5. SHUT-DOWNS AND OUTAGES SHALL BE SCHEDULED IN
ADVANCE WITH THE COR. REFER TO SPECIFICATIONS -
GENERAL REQUIREMENTS AND GENERAL NOTES FOR
NUMBER OF DAYS' NOTICE REQUIRED PRIOR TO WORK.
REFER TO SPECIFICATIONS SEC. 01 00 00 GENERAL REQ'TS.
FOR ADD'L INFO. RE: PHASING.
PHASING NOTES:
ADD ALTERNATES ARE TO BE PROVIDED PER THE SPECIFICATIONS -
GENERAL REQUIREMENTS FOR THE FOLLOWING ITEMS.
1. REMOVE EXISTING LOOSE-LAID BALLASTED EPDM ROOFING
AND ROOF INSULATION SYSTEMS; REPLACE WITH NEW
RIGID ROOF INSULATON, TPO ROOFING, FLASHINGS,
ACCESSORIES, ETC. FOR COMPLETE INSTALLATION. SEE
ARCHITECTURAL DRAWINGS.
2. REPLACE EXISTING EMERGENCY BACKUP GENERATOR AT
BLDG. 11 WITH NEW GENERATOR. SEE MEP DRAWINGS.
ALTERNATES:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 Fax: 402.291.9193
AH. INZ
Shaffer & Stevens 9910 North 48th Street
Omaha, Nebraska68152
Phone: 402.455.7698 Fax: 402.455.7597
504-18-119
IMEG Corp.
14755 Preston Rd., Suite 845
Dallas, TX 75254
Phone:(972) 239-6100
15% Design Submission 07/14/2020
20% Design Submission
30% Design Submission
35%/SD1 Schematic Design Submission - Request for Proposal
AMI Environmental Inc
8802 S 135th Street
Omaha, NE 68138
Phone:(402) 397-5001
08/14/2020
FOR REFERENCE
ONLY NOT FOR
CONSTRUCTION
09/08/2020
11/17/2020
C
L H
D C
\H o m e \t fi e s e lm a n
\R e v it
M o d e ls \R
-5
-1 -1
B o ile rs tf ie s e lm a n A
G Y
.r v t
/1 /2
:1
:2
A
M
G-002
SHEET INDEX, ABBREVIATIONS, SYMBOLS
& GENERAL NOTES
RJRNovember 17, 2020
Replace Boilers & PipingSD-1 35% SUBMITTAL -
REQUEST FOR PROPOSAL
Thomas E. Creek VAMC-Amarillo,TX
Index of Drawings - Architectural
SHEET
NO. SHEET NAME
AS100 ARCHITECTURAL SITE PLAN & LOCATION
ST-AE100 STEAM TUNNEL PLAN
11-AD101 LOWER LEVEL & FIRST FLOOR PLANS - DEMOLITION BLDGS. 11, 16
& 19
11-AD102 MEZZANINE PLANS - DEMOLITION - BLDG. 11
11-AD201 EXTERIOR ELEVATIONS - DEMOLITION - BLDGS. 11, 16 & 19
11-AD301 BUILDING SECTIONS - DEMOLITION - BLDGS. 11, 16 & 19
11-AD310 WALL SECTIONS - DEMOLITION - BLDG. 11
11-AE101 LOWER LEVEL & FIRST FLOOR PLANS - RENOVATION - BLDGS. 11,
16 & 19
11-AE102 MEZZANINE PLANS - RENOVATION - BLDG. 11
11-AE110 ROOF PLANS - DEMOLITION & RENOVATION - BLDGS. 11, 16 & 19
11-AE201 EXTERIOR ELEVATIONS - RENOVATION - BLDGS. 11, 16 & 19
11-AE301 BUILDING SECTIONS - RENOVATION - BLDGS. 11 & 16
11-AE310 WALL SECTIONS - RENOVATION - BLDG. 11
AE401 PARTIAL FLOOR PLANS - BLDGS. 1, 4, 28 & 29 MECHANICAL ROOMS
Index of Drawings - General
SHEET
NO. SHEET NAME
G-001 COVER SHEET
G-002 SHEET INDEX, ABBREVIATIONS, SYMBOLS & GENERAL NOTES
Index of Drawings - Mechanical
SHEET
NO. SHEET NAME
MD010 MECHANICAL DEMOLITION SITE PLAN
M-010 MECHANICAL SITE PLAN
01-M-100 EXISTING CONDITIONS PLAN & PHOTOS - MECH ROOM - BLDG. 1
04-M-100 EXISTING CONDITIONS PLAN & PHOTOS - MECH ROOM - BLDG. 4
11-M-100 FIRST FLOOR PLAN - MECHANICAL - BLDGS. 11, 16 & 19
11-M-101 PARTIAL LOWER LEVEL - MECHANICAL - BLDG. 11
11-M-102 ROOF PLAN - MECHANICAL - BLDG. 11
28-M-100 EXISTING CONDITIONS PLAN & PHOTOS - MECH ROOM - BLDG. 28
29-M-100 EXISTING CONDITIONS PLAN & PHOTOS - MECH ROOM - BLDG. 29
M-300 MECHANICAL DETAILS
M-301 MECHANICAL DETAILS
M-302 MECHANICAL DETAILS
M-400 MECHANICAL FLOW DIAGRAMS - WATER AND STEAM - DEMOLITION
M-401 MECHANICAL FLOW DIAGRAMS - WATER AND STEAM
M-402 MECHANICAL FLOW DIAGRAMS - WATER TREATMENT
M-403 MECHANICAL FLOW DIAGRAMS - BOILER - FUEL OIL - DEMOLITION
M-404 MECHANICAL FLOW DIAGRAMS - BOILERS - FUEL OIL
M-601 BOILER PLANT DEMO ISOMETRIC
M-602 BOILER PLANT NEW WORK ISOMETRIC
Index of Drawings - Electrical
SHEET
NO. SHEET NAME
E-100 ELECTRICAL COVER SHEET
11-ED100 FIRST FLOOR PLAN ELECTRICAL - DEMOLITION - BUILDGS 11, 16, &
11-E-100 FIRST FLOOR PLAN ELECTRICAL - BUILDGS 11, 16, & 19
E-300 ELECTRICAL DETAILS
Index of Drawings - Structural
SHEET
NO. SHEET NAME
11-S-101 SCHEMATIC FOUNDATION PLAN - BLDG. 11 (FOR GENERAL
INFORMATION ONLY)
16/19-S-101 SCHEMATIC FOUNDATION PLAN - BLDGS. 16 & 19 (FOR GENERAL
INFORMATION ONLY)
Index of Drawings - Phasing
SHEET
NO. SHEET NAME
00-PH103 PHASING PLAN - CAMPUS - PHASE 2
11-PH101 PHASING PLANS - BOILER PLANT - PHASE 1
11-PH102 PHASING PLANS - BOILER PLANT - PHASE 2
Index of Drawings - Resource
SHEET
NO. SHEET NAME
11-RA101 EXISTING CONDITIONS PLAN & PHOTOS - INTERIOR - BLDG. 11
11-RA102 EXISTING CONDITIONS PLAN & PHOTOS - MEZZANINES - BLDG. 11
& 16
11-RA103 EXISTING CONDITIONS PLAN & PHOTOS - EXTERIOR - BLDG. 11 &
11-RA104 EXISTING CONDITIONS PLAN & PHOTOS - ROOF - BLDG. 11 & 16
19-RA101 EXISTING CONDITIONS PLAN & PHOTOS - INTERIOR & EXTERIOR -
BLDG. 19
11-RM100 EXISTING CONDITIONS PLAN & PHOTOS - MECHANICAL - BLDG. 11,
16, 19
11-RM101 EXISTING CONDITIONS PLAN & PHOTOS - MECHANICAL - BLDG.
11,16, 19
ST-RM100 EXISTING CONDITIONS PLAN AND PHOTOS MECHANICAL - STEAM
TUNNELS
Revisions: Date:
| Sheets |
| G-001 - COVER SHEET |
| G-002 - SHEET INDEX, ABBREVIATIONS, SYMBOLS & GENERAL NOTES |
File details come from the government source that posted it. Updated .