Mech 035 - Pages 7-12.pdf

PDF 26 MB Posted

Attached to
Y1DA--504-18-119 Replace Boilers and Piping Federal contract opportunity
Solicitation number
36C25722R0010
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17

About this file

This document provides details on a federal contract solicitation. The solicitation number is 36C25722R0010 from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17 for replacing boilers and piping at VA-22-00004245. The opportunity type is listed as a solicitation. No further details are provided on products or services required, response dates, pricing terms, set asides, or other salient information needed to fully understand the requirements of this contracting opportunity.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--504-18-119 Replace Boilers and Piping, newest first.
File Type Posted
Amendment 36C25722R0010 0001.docx DOCX document
Answers to Questions 36C25722R0010 DB Replace Boilers.pdf PDF
VA NOTICE OF LIMITATIONS ON SUBCONTRACTING REQUIREMENT.pdf PDF
Past Performance Questionnaire.pdf PDF
Mech 035 - Pages 1-3.pdf PDF
Mech 035 - Pages 4-6.pdf PDF
OSHA - EMR requirement.pdf PDF
BP-3-Boiler-steam.pdf PDF
BP-1-Boiler-fueloil.pdf PDF
AS ST Series Sheets.pdf PDF
AD AE Series Sheets.pdf PDF
Elect 035.pdf PDF
G Series Sheets.pdf PDF
BP-4-Water-Treatment.pdf PDF
36C25722R0010_1.docx DOCX document
Phasing sheets.pdf PDF
Struct 035.pdf PDF
SELF-PERFORMED CALCULATIONS.pdf PDF
Mech 035 - Pages 8-19.pdf PDF
BP-2-Boilers-natgasandpropane.pdf PDF
20-09 035 Narrative 02 1r1 Phasing Narrative.pdf PDF
20-09 035 Narrative 06 1r1 Civil-LS Design Narrative.pdf PDF
20-09 035 Narrative 13 1r1 Specs TOC 000110 035 21-06-30.pdf PDF
Show all 23

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

11-EF-1

NEW

EXHAUST

FAN

EXISTING PACKAGED

ROOFTOP UNIT

TO REMAIN

EXISTING SHOWER /

LOCKER EXHAUST

FAN TO REMAIN

1 11

EXISTING PRESS.

REDUCING STATION

SAFETY RELIEF VENT

TO REMAIN

2.2

C K M N

4A

A

2.7

B

GD E F

3.5

L

2.2

H

1A

JC1

EXISTING ROOF

ACCESS HATCH

EXISTING BOILER

#4 BREECHING TO

REMAIN

EXISTING BOILER

STEAM SAFETY

VALVE VENT TO

REMAIN

11-EF-2

EXISTING SURGE

VENT THROUGH

ROOF TO REMAIN

6 11-EF-3

2.2

C K M N

4A

A

2.7

B

GD E F

3.5

L

2.2

H

1A

JC1

5 3

4 4

11 1

EXISTING

EXHAUST

FAN TO BE REMOVED

EXISTING PACKAGED

ROOFTOP UNIT

TO REMAIN

EXISTING SHOWER /

LOCKER ROOM EXHAUST

FAN TO REMAIN

EXISTING PRESS.

REDUCING STATION

SAFETY RELIEF VENT

TO REMAIN

EXISTING BOILER

#4 BREECHING TO

REMAIN

EXISTING ROOF

ACCESS HATCH

EXISTING BOILER

STEAM SAFETY

VALVE VENT TO

REMAIN

EXISTING SURGE

VENT THROUGH

ROOF TO REMAIN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:5

:0

P M

11-M-102

ROOF PLAN - MECHANICAL- BLDG. 11

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

KEYNOTES:

1. NEW 2" BOILER SAFETY RELIEF VENT

THROUGH ROOF AND EXTEND 7'-0" ABOVE

ROOF LEVEL.

2. NEW 8" STEAM BOILER TEST HEADER VENT

THROUGH ROOF AND EXTEND 7'-0" ABOVE

ROOF LEVEL.

3. NEW 2" DEAERATOR STEAM RELIEF VENT

THROUGH ROOF AND EXTEND 7'-0" ABOVE

ROOF LEVEL.

4. NEW BOILER BREECHING WITH WEATHER CAP.

EXTEND 7'-0" ABOVE ROOF LEVEL. UTILIZE

EXISTING ROOF PENETRATION AND PROVIDE

OFFSETS AS REQUIRED. PROVIDE FLASHING

AND COUNTER FLASHING AT NEW BOILER

STACK THROUGH ROOF.

5. NEW 6" BOILER BLOW DOWN SEPARATOR

RELIEF VENT THROUGH ROOF. EXTEND 7'-0"

ABOVE ROOF LEVEL.

6. NEW EXHAUST FANS FOR BOILER PLAN

VENTILATION.

7. NEW GENERATOR EXHAUST. (ADD ALTERNATE)

N O R

HT

1/8" = 1'-0"

ROOF PLAN - BLDG. 11 - MECHANICAL

N O R

HT

1/8" = 1'-0"

ROOF PLAN - BLDG. 11 DEMOLITION - MECHANICAL

DEMOLITION KEYNOTES:

1. DEMOLISH 2" BOILER SAFETY RELIEF VENT

THROUGH ROOF.

2. DEMOLISH 8" STEAM BOILER TEST HEADER

VENT THROUGH ROOF.

3. DEMOLISH BOILER HOUSE EXHAUST FANS AND

ROOF CURBS.

4. DEMOLISH BOILER BREECHING AND WEATHER

CAP.

5. DEMOLISH 6" BOILER BLOW DOWN SEPARATOR

RELIEF VENT.

6. DEMOLISH EXISTING GENERATOR EXHAUST.

Revisions: Date:

T U N N E L

S T A

IR

S

EXISTING

PRESS. RED.

STATION TO

REMAIN

MPS UP

EXISTING

HOT WATER HEAT

EXCHANGERS

TO REMAIN

REPLACE EXISTING

DOMESTIC HOT WATER

HEATING HEAT

EXCHANGER

EXISTING

CONDENSATE

PUMP TO REMAIN

REMOVE EXISTING

ABANDONED STEAM

DROP

EXIST. PRESSURE

REDUCING VALVE

EXIST. STEAM

PRESS.SAFETY

VALVE

MPS

EXISTING FLASH

TANK TO REMAIN

EXISTING

HOT WATER

PUMPS TO

REMAIN

NO SCALE2

PIPE DROP TO BE REMOVED

NO SCALE3

POOR INSULATION

NO SCALE4

WATER HEATER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:4

:4

P M

28-M-100

EXISTING CONDITIONS PLAN AND

PHOTOS - MECH ROOM - BLDG 28

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

N O R

HT

1/8" = 1'-0"

BASEMENT FLOOR PLAN - BLDG. 28 - MECHANICAL ROOM 1158

RECEPTION

RECOVERY

STORAGE

MED

GAS

SOILED

DECON

RAT SUPPLY

NURSE

STATION

ENDO

ROOM

MECHANICAL

ROOM

144 127

PRESS. RED.

STATION

CONDENSATE

PUMP TO REMAIN

REPLACE AND RECONFIGURE

CONDENSATE PIPING TO FLASH

TANK. REPLACE FLASH TANK

REPLACE EXISTING

DOM. HOT WATER

HEAT EXCHANGERS

6" HPS

FROM

TUNNEL

2" PUMPED

CONDENSATE

RETURN

4" MPS

HEAT EXCHANGER

W/COND. PUMP

4" MPS

HIGH

PRESSURE

RETURN

STEAM

VENT

MEDIUM

PRESSURE

RETURN

AIR SEPARATOR

INSULATE

CONDENSATE PIPING

EXISTING HOT

WATER HEATING

HEAT EXCHANGERS

TO REMAIN

29-FT-1

NO SCALE2

REINSULATE CONDENSATE PIPING

NO SCALE3

FLASH TANK AND PIPING

NO SCALE4

CONDENSATE PUMP

NO SCALE5

FLASH TANK AND CONDENSATE PIPING

NO SCALE6

REINSULATE CONDENSATE PIPING

NO SCALE7

FLASH TANK TO CONDENSATE PIPING

NO SCALE8

DOMESTIC WATER HEATER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:4

:5

P M

29-M-100

EXISTING CONDITIONS PLAN AND

PHOTOS - MECH ROOM - BLDG 29

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

N O R

HT

1/8" = 1'-0"

BASEMENT FLOOR PLAN - BLDG. 29 - MECHANICAL ROOM 0528

GENERAL NOTES:

1. REINSULATE CONDENSATE PIPING FROM PRV

AND HEAT EXCHANGERS TO FLASH TANK.

KEYNOTES:

1. REROUTE ALL MEDIUM PRESSURE

CONDENSATE RETURN BACK TO

DEARERATOR, IN BOILER PLANT, SEPERATE

FROM LOW PRESSURE OR PUMPED

CONDENSATE PIPING.

ELEVATION

CONCRETE BASE BOILER ROOM

FINISHED FLOOR

BURNER

SIGHTFLOW INDICATOR

WITH ROTOR (ORIENT

WINDOWS TO FACE UP

AND DOWN)

20mm [3/4"]

TO BLOWOFF LINE

15mm [1/2"]

STEAM PRESSURE GAGE

(0-2000kPa [0-300 PSIG])

HIGH PRESSURE

CUTOUTS

FEEDWATER LEVEL CONTROL

UNIT LOW WATER CUTOFF

BOILER

PLUGGED CROSS

(TYPICAL)

AUXILIARY LOW

WATER CUTOFF LOW

WATER ALARM HIGH

WATER ALARM

AUXILIARY LOW WATER

CUTOFF SHUNT SWITCH

(LOCATE WITHIN 900mm [3'] OF

ALWCO DRAIN VALVE)

20mm [3/4"]

TO BLOWOFF

LINE

SIGHTFLOW INDICATOR

WITH ROTOR (ORIENT

WINDOWS TO FACE UP

AND DOWN)

32mm [1 1/4"]

GAGE GLASS

LOW WATER CUTOFF SHUNT

SWITCH (LOCATE WITHIN 3'

[900mm] OF LWCO AND GAGE

GLASS DRAIN VALVES)

BALL VALVES PROHIBITED

(TYP)

STEAM NOZZLE

m m

32mm [1 1/4"] m m

32mm [1 1/4"]

600mm [2'] MAX.

LADDER HANDRAIL

BOILER

ACCESS PANEL

STACK

ECONOMIZER

SAFETY VALVE

VENT THRU ROOF

VENT

MANWAY

NON-RETURN

STOP-CHECK VALVE

BURNER

PLAN VIEW

HANDRAIL

PLATFORM

TOP OF BOILER

CASING

LADDER

STEAM LEAD

NON-RETURN

STOP-CHECK VALVE

BOILER

CONCRETE PAD

BOILER ROOM FLOOR

BURNER

ELEVATIONNOTE:

SUPPORT PLATFORM FROM FINISHED

FLOOR OR FROM BOILER IF BOILER

MANUFACTURER PROVIDES BOILER

ATTACHMENTS AND APPROVES

INSTALLATION. COORDINATE WITH

STRUCTURAL

HANDLE FOR VALVE TO BE

ACCESSED FROM PLATFORM

LC

762mm [2'-6"]

PLATFORM

300mm [12"]

25mm [1"]

D

S W

F W

S

B W

S

B W

S

B W

S

15mm [1/2"]

FROM EACH

BOILER

8mm [1/4"]

FROM

DEAERATOR

20mm [3/4"]

COOLING

WATER

8mm [1/4"]

SAMPLE

OUTLET

20mm [3/4"]

ANTI-SYPHON

VACUUM BREAKER

0-83°C [30-180°F]

SAMPLE COOLER

PROVIDE SEPARATE COOLERS FOR BWS

AND FWS. MOUNT BWS COOLER 1.2M [4']

ABOVE FINISHED FLOOR ON WALL OR

COLUMN. MOUNT FWS COOLER 0.6M [2'] ±

ABOVE MEZZANINE FLOOR AT DEAERATOR.

15mm [1/2"]

ELEVATION

FD

S W

PROVIDE SAME WATER SAMPLE AS

COOLER'S PIPING ARRANGEMENT

AND EQUIPMENT FOR THE BOILER

WATER AS SHOWN FOR THE

FEEDWATER SAMPLE COOLER.

127mm [5"] THICK

CONCRETE HOUSEKEEPING

PAD

FLOOR

20mm [3/4"] DRAIN, DISCHARGE INTO NEAREST

FLOOR DRAIN, NC.

THERMOMETER

GRAVITY RETURN

FROM FLASH TANK

IF SHOWN ON

FLOOR PLAN

SCHEDULE 80

PUMP DISCHARGE

TO PLANT

CONTROL CABINET

VENT

RECEIVER

WATER LEVEL

GAUGE

THERMOMETER

FLUSHING

CONNECTION

SCHEDULE 80

STEEL PIPE

SCHEDULE 80

STEEL PIPE

LPR

R

F W

P S

FROM FEEDWATER DEAERATOR

TO FEEDWATER DEAERATOR

WITH BYPASS TO CONDENSATE

STORAGE TANK

R

FWPS

[30" VAC-30PSI]

0-2000kPa

[0-300PSI]

0-150°C [30-300°F]

F W

P D

-1

F W

P D

-2

BOILER FEEDWATER

PUMP NO. 1

(TYPICAL)

F W

P S

R

F W

P D

-1

F W

P D

-2

BOILER FEEDWATER

PUMP NO. 2

F W

P S

R

F W

P D

-1

F W

P D

-2

BOILER FEEDWATER

PUMP NO. 3

FWPD-1

FWPD-2

TO BOILERS

AND ECONOMIZERS

NOTE:

CAPACITY OF EACH PUMP

APPROX. 125% OF ONE BOILER

FLEX

CONNECTION

RECIRCULATION

ORIFICE SEE DETAIL

THIS SHEET

XXS PIPE

2000kPA

[300 PSI]

FITTINGS

PLUG

TO TANK

COUPLING

UNION

COUPLING

ORIFICE

PUMP DISCHARGE

DETAIL - PUMP RECIRCULATION

ORIFICE ASSEMBLY

EMERGENCY BOILER

CONNECTION TO

OUTSIDE OF BUILDING

762mm VAC-207kPa m m

[3

M

BO

CF

C B

D

BOILER

(TYPICAL)

ECONOMIZER

(TYPICAL)

V

D

OSD

V T

R

D

CV-6,7,8

10-260°C [50-500°F]

F W

P D

FWPD

F W

P D

FWPD

SRV-1

F W

P D

-2

F W

P D

-1 F

R O

M F

E E

D W

A T

E R

P U

M P

S

20mm [3/4"]

VENT INTO

BOILER ROOM

20mm [3/4"]

STACK

B W

S

BO

51mm [2"]

T O

S A

M P

L E

C O

O L E

R

20mm 3/4" FROM

CHEMICALFEEDER

TO BO TANK

OR, IF SPECIFIED, TO

BLOWDOWN HEAT

RECOVERY

BO

2ND BO LINE

REQUIRED IF BOILER

HAS TWO BO

CONNECTIONS

FWPD

CONTROLLER

BOILER WATER LEVEL CONTROL SCHEMATIC

(SEE SPECS FOR TYPE OF SYSTEM)

CV-6,7,8

BOILER WATER LEVEL

TRANSMITTER

BOILER STEAM FLOW

TRANSMITTER

BOILER FEEDWATER

PRESSURE TRANSMITTER

S

IN

G L E

E L E

M E

N T

S Y

S T

E M

D U

A L

E L E

M E

N T

S Y

S T

E M

T H

R E

E E

L E

M E

N T

S Y

S T

E M

0-150°C [30-300°F]

0-2000kPa

[0-300PSIG]

C V

-9 ,1

,1

DESIGNER'S NOTE:

SEE SD232111-04 BASIC FLOW DIAGRAM -

CONDENSATE AND BOILER FEEDWATER FOR

COMPLETE SYSTEM.

PROVIDE CONTROL VALVES HERE

THAT WOULD MODULATE IN

UNISON (ONE OPENS, THE OTHER

ONE CLOSES) TO PREVENT TOO

LOW A FLUE GAS TEMPERATURE

OUT OF THE ECONOMIZER.

PROVIDE

TEMPERATURE

TRANSMITTERS

HERE

0-2000kPa

[0-300PSIG]

20mm [3/4"]

DESIGNER'S NOTE:

SEE SD232111-04 BASIC FLOW DIAGRAM -

CONDENSATE AND BOILER FEEDWATER FOR

COMPLETE SYSTEM.

SW

CTPD

CONTROLLER

WATER LEVEL

TRANSMITTER

WATER LEVEL CONTROL SCHEMATIC

LPS

HPR/MPR

F W

P S

O F

L

FROM PRV STATION

(FOR DETAIL SEE

SD232213-01)

FEEDWATER DEAERATOR

AND STORAGE TANK

TO CONDENSATE STORAGE

TANK. TANK TO BE ASME

STAMPED FOR THE DESIGN

PRESSURE AND TEMPERATURE

OF THE APPLICATION.

EMERGENCY MAKE-UP

NORMAL

MAKE-UP

CTPD

CV-3

CV-4

NC

40mm [1 1/2"]

NCNCNCNC

25mm [1"]

LEVEL

TRANSMITTER

LOW LEVEL

ALARM SW

GAGE GLASS

HIGH LEVEL

ALARM SW

OFL CONTROL

SWITCH

D

OSD

NC

51mm [2"]

F W

S

C F

P

6mm [1/4"]

TO

SAMPLE

COOLER

TO

BOILER

FEEDER

PUMPS

FROM

CHEMICAL

PUMP

VALVE LOCKED OPEN

OFL PIPE IN TANK-INLET

150mm [6"] BELOW LOW LEVEL

ALARM SET POINT

CV-5

SW

R

FROM BOILER FEED

WATER PUMPS SEE SD

232111-07

0-150°C [30-300°F]

TOP OF TANK

OFL LINE

HIGH LEVEL ALARM

LOW LEVEL ALARM

EMERGENCY MAKE-UP

NORMAL WATER LEVEL

CV-3

CV-4

OFL

OFL

CONTROLLER

OFL CONTROL

SWITCH

OVERFLOW CONTROL SCHEMATIC

CV-5

SAFETY DEVICE MANUAL

CAN BE 1/3 OF TANK

PROVIDE STEAM CONTROL

VALVE MODULATED TO

CONTROL TEMPERATURE AT

THE SCRUBBING SECTION OF

THE DEARERATOR.

0-150°C [30-300°F]

[30" VAC-30PSI]

762mm VAC-207kPa

25mm [1"]

B Y

D A

M F

G R m m m m m m

C OF TANKL

[4

[4

[4

D

PROVIDE UNION UNLESS

SAFETY VALVE HAS

FLANGED OUTLET

SAFETY VALVE

OPEN DRAIN (NOTE 3)

CONNECTION TO

PRESSURE VESSEL

OR PIPE

VENT PIPE THROUGH ROOF

SUPPORT AS INDICATED ON

DWGS. (NOTES 1, 2)

PIPE THREADED INTO ELBOW

(SAME SIZE AS ELBOW)

DRIP PAN ELBOW

(SECTIONAL VIEW)

20mm [3/4"] DRAIN TO

FLOOR DRAIN OR OPEN

SIGHT DRAIN (NOTE 4)ELEVATION

NOTES:

1. UNLESS OTHERWISE SHOWN ON THE DRAWINGS, SIZE THE VENT PIPE SO THAT STEAM IS

NOT BLOWN OUT AT THE VENT PIPE ENTRANCE. UTILIZE THE CALCULATION METHOD

CONTAINED IN ANSI B31.1. POWER PIPING CODE, APPENDIX II. THE VENT PIPE SHOULD GO

VERTICAL THRU THE ROOF WITH NO TURNS OR ANGLES. WHERE REQUIRED THERE SHALL

BE NO MORE THEN A TOTAL OR 180 DEGREES IN DIRECTIONAL CHANGES MADE WITH 45

DEG. ELBOWS.

2. VENT PIPE SHALL TERMINATE 1829mm [6'] MIN. ABOVE FINISHED ROOF.

3. DISCHARGE OF DRAIN SHALL BE DIRECTED AWAY FROM PLATFORMS OR OTHER AREAS

WHERE PERSONNEL MAY OCCUPY.

4. DO NOT CONNECT ANY OTHER DRAIN TO THE DRIP PAN ELBOW DRAIN PIPE.

5. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

FLEXIBLE

CONNECTOR

m m [1

M

IN

610mm

[24" MAX]

76mm [3"]

TT

PT

PRESSURE

TRANSMITTER

TEMPERATURE

TRANSMITTER

FLOW METER

INTERFACE WITH

BACNET SYSTEM

DIFFERENTIAL

PRESSURE (DP)

CELL STEAM FLOW

MEASUREMENT

SHUTOFF VALVE

TO METERING

SYSTEM

BUILDING INCOMING

MAIN STEAM

NOTE:

MAINTAIN UPSTREAM AND DOWN STREAM DISTANCES RECOMMENDED BY

METER MANUFACTURERS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:0

:1

P M

M-300

MECHANICAL DETAILS

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

NO SCALE

FIRE TUBE BOILER AUXILIARY WATER LEVEL SAFETY PIPING

1 NO SCALE

ACCESS PLATFORM ARRANGEMENT

2 NO SCALE

WATER SAMPLE COOLERS BOILER WATER AND FEED WATER

NO SCALE

CONDENSATE PUMPS PIPING CONNECTIONS

4 NO SCALE

BOILER FEEDWATER PUMPS FLOW DIAGRAM

5 NO SCALE

BOILER FLOW DIAGRAM

NO SCALE

FEEDWATER DEAERATOR FLOW DIAGRAM

7 NO SCALE

STEAM SAFETY VALVE

NO SCALE

STEAM METER DETAIL

m m

M A

X

SIDE VIEW TRAPEZE HANGER FOR UP TO

453KG [1000 LB.] UNIFORM LOAD

ADJUSTABLE CLEVIS HANGER TYPE 1 - SEE SPECIFICATIONS ADJUSTABLE CLEVIS HANGER TYPE 43 - SEE SPECIFICATIONS

MAXIMUM PIPE/TUBING SUPPORT SPACING

NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.

NOM. SIZE

PIPE

TUBING

mm

[IN]

mm

[FT]

mm

[FT]

THRU 20

[THRU 3/4]

[7]

[5]

[1]

[7]

[6]

[11/4]

[7]

[7]

[11/2]

[9]

[8]

[2]

[10]

[8]

[21/2]

[11]

[9]

[3]

[12]

[10]

[4]

[14]

[12]

[5]

[16]

[13]

[6]

[17]

[14]

[8]

[19]

[16]

[10]

[22]

[12]

[23]

[14]

[25]

[16]

[27]

[18]

[28]

[20]

[30]

[24]

[32]

PROVIDE INSULATION

SHIELD & INSERT FOR ALL

PIPING (200mm [8"] MIN.)

43mm [1-5/8"] 12 GAUGE CHANNEL OR 50x50x6.4mm [2"X2"X1/4"] ANGLE

15mm [1/2"] DIA. HANGER RODS WITH 900mm [36"] MAX. SPACING

ON EACH CHANNEL

WELD

SADDLE

INSULATION SHIELD

AT HANGER

PROVIDE HIGH COMPRESSIVE

STRENGTH INSULATION (9

PSF MIN. DENSITY) UNDER

INSULATION SHIELD

INSULATION (VAPOR

BARRIER TYPE IS

REQUIRED FOR LOW

TEMPERATURE PIPE)

HANGER ROD

NOTE:

SEE SPECIFER FOR DETAILED

HANGER REQUIREMENTS

BAND

A

A

BB

SECTION A-A (BASE NOT POURED WITH SLAB)

SECTION A-A (BASE POURED WITH FLOOR SLAB)

PLAN

TYPICAL ANCHOR

BOLT NUT & WASHER

SECTION B-B

EQUIPMENT BASE PLATE

PROVIDE #3 BARS 12" [300mm] O.C.

EACH WAY IN THE BASE & DOWEL

BASE TO FLOOR

EQUIPMENT BASE PLATE

PROVIDE DOUBLE SLAB

REINFORCING IN BASE AREA

WELD HEAD TO PLATE OR

BEND OVER END 5D

FLOOR

PIPE SLEEVE (5D, 3"

[75mm] MIN.)

ANCHOR

BOLT (TYP)

CONCRETE BASE

NOTE:

L & W DIMENSIONS SHALL

BE 6" [150mm] GREATER

THAN THE EQUIPMENT

BASE PLATE.

[400mm]

M

IN

[1 m m

M

IN

[1 m m

TYPICAL ANCHOR

BOLT NUT & WASHER

[2 m m

L /1

L

/1

D 1

16"

2D

L

W

D

5D

CW

TEMPERATURE REGULATOR,

CHECK VALVE, STRAINER,

AND THERMOMETER

CONNECT TO

DRAIN

FROM BOILER

BLOWDOWN

STEAM VENT

THRU ROOF

FLOOR

102mm [4"]

HEIGHT DEPENDING

ON INLET OR PUMP

TO BE INSTALLED.

PROVIDE PIPE

SUPPORT

AND SADDLES.

0-2000kPa [30°-300°F]

FLASH TANK DIELECTRIC FITTING

(WHEN RETURN IS COPPER)

RETURN

H.P. DRIP RETURNS.

(SEE FLOOR PLANS)

51mm [2"] VENT TO

OUTSIDE OF BUILDING

FLOOR

GRAVITY RETURN TO

CONDENSATE PUMP

PIPE WITH 6mm [1/4"] PERFORATIONS

SHALL EXTEND FULL LENGTH OF

TANK AND SHALL BE SAME

DIAMETER OF CONDENSATE

RETURN CONNECTION TO TANK.

TOTAL AREA OF ALL 6mm [1/4"]

PERFORATIONS SHALL BE

EQUIVALENT TO THE TRANSVERSE

AREA OF THE PIPE.

CONDENSATE

PUMP CAP. - L/S

(GPM)

APPROX. CAP. OF

FLASH TANK - L

(GALLONS)

SIZE OF FLASH

TANK - mm (in)

0 THRU 237

[0 THRU 15]

253THRU 349

[16 THRU 22]

364 THRU 475

[23 THRU 30]

491 THRU 586

[31 THRU 37]

602 THRU 713

[38 THRU 45]

729 THRU 951

[46 THRU 60]

967 THRU 1189

[61 THRU 75]

1205 THRU 1537

[76 THRU 97]

1553 THRU 2377

[98 THRU 150]

61 [16]

91[24]

117[31]

140[37]

159[42]

231[61]

284[75]

360[95]

587[155]

356mm DIA X 610mm LONG

[14 DIA. X 24 LONG]

365mm DIA X 914mm LONG

[14 DIA. X 36 LONG]

406mm DIA X 914mm LONG

[16 DIA. X 36 LONG]

406mm DIA X 1067mm LONG

[16 DIA. X 42 LONG]

406mm DIA X 1219mm LONG

[16 DIA. X 48 LONG]

457mm DIA X 1372mm LONG

[18 DIA. X 54 LONG]

457mm DIA X 1676mm LONG

[18 DIA. X 66 LONG]

610mm DIA X 1372mm LONG

[24 DIA. X 54 LONG]

610mm DIA X 1981mm LONG

[24 DIA. X 78 LONG]

FLASH TANK SCHEDULE

NOTES:

1. SEE FLOOR PLANS FOR PIPE SIZES.

2. SEE EQUIPMENT SCHEDULES FOR VALVE DATA AND PIPE SIZES D1 AND D2. INSTALL VALVES AS

RECOMMENDED BY MANUFACTURER.

3. MAKE BYPASS VALVE DISCHARGE PIPE THE SAME SIZE AS D2 FOR THE LARGEST PRV.

4. PROVIDE NECESSARY UNIONS FOR THE REMOVAL OF VALVE WITH SCREWED CONNECTIONS.

5. SLOPE PILOT CONTROL LINE FROM PRESSURE REDUCING VALVE TO DOWN STREAM STEAM PIPING. MIMIMUM

SLOPE SHALL BE 25'/100', 25mm/300mm [1"/12"]

SIPHON (TYP.)

VENT TO ATMOSPHERE

PILOT CONTROL LINE

REDUCER

(TYP.) IF

REQUIRED

NOTE 1

D1

N.C.

D2

D2

NOTE 1

NOTE 3

INVERTER

BUCKET TRAP

ASSEMBLY TYP.

PSV

V

4XD2 MIN.

20XD2 MIN.10XD1 MIN.

NOTES:

1. ALL DRIP POINTS ON STEAM MAINS SHALL BE PROVIDED WITH A 300mm [12"] MINIMUM HIGH

DRIP LEG FROM BOTTOM OF STEAM MAIN TO TRAP INLET. DRIP LEG SHALL HAVE 150mm [6"]

SCALE POCKET BELOW TRAP INLET.

2. PROVIDE BYPASS PIPING.

SEE DRAWINGS

FOR PIPE SIZES

TO RETURN MAIN

SCHEDULE 80 STEEL

PIPE

PIPE SIZE SHALL

BE SAME SIZE

AS TRAP

INVERTED BUCKET TRAP.

SEE PLANS, AND

SCHEDULES

DIELECTRIC FITTING

WHERE RETURN IS

COPPER PIPE

FLOW

SCHEDULE 80

STEEL PIPE

BYPASS-INSTALL IN HORIZONTAL

PLANE LEVEL WITH TRAP OR IN

VERTICAL PLANE & BELOW TRAP

DRIP LEG OR EQUIPMENT CONNECTION.

MAKE THE SAME SIZE AS THE SUPPLY

MAIN OR EQUIPMENT CONNECTION.

SEE NOTE 1

1" GATE VALVE

USE 4-BOLT RAISED FACE

FLANGES

m m m m

[1

M

IN

[6

M

IN

NOTE:

ALL DRIP POINTS ON STEAM MAINS SHALL BE PROVIDED WITH A 300mm [12"] MINIMUM HIGH

DRIP LEG FROM BOTTOM OF STEAM MAIN TO TRAP INLET. DRIP LEG SHALL HAVE 150mm [6"]

SCALE POCKET BELOW TRAP INLET.

TO RETURN MAIN

PIPE SIZE SHALL BE SAME

SIZE AS TRAP

FLOAT AND THERMOSTATIC

TRAP. SEE PLANS, AND

SCHEDULES

DIELECTRIC FITTING

WHERE RETURN IS

COPPER PIPE

FLOW

SCHEDULE 80

STEEL PIPE

BYPASS-INSTALL IN HORIZONTAL PLANE

LEVEL WITH TRAP OR IN VERTICAL

PLANE & BELOW TRAP PROVIDE BYPASS

PIPING FOR ALL TRAPS 25mm [1"] AND

LARGER.

DRIP LEG OR EQUIPMENT

CONNECTION. MAKE THE SAME

SIZE AS THE SUPPLY MAIN OR

EQUIPMENT CONNECTION. SEE

NOTE 1

SCHEDULE 80 STEEL PIPE

SEE DRAWINGS FOR PIPE

SIZES

25mm [1"]

GATE VALVE

USE 4-BOLT RAISED FACE

FLANGES

m m m m

[1

M

IN

[6

M

IN

NOTE:

1. ALL DRIP POINTS ON STEAM MAINS SHALL BE PROVIDED WITH A 300mm [12"] MINIMUM HIGH DRIP LEG

FROM BOTTOM OF

STEAM MAIN TO TRAP INLET. DRIP LEG SHALL HAVE 150mm [6"] SCALE POCKET BELOW TRAP INLET.

TO RETURN MAIN

PIPE SIZE SHALL BE SAME SIZE AS

TRAP

THERMOSTATIC TRAP. SEE

OTHER STEAM DETAILS,

PLANS, AND SCHEDULES

DIELECTRIC FITTING

WHERE RETURN IS

COPPER PIPE

FLOW

SCHEDULE 80

STEEL PIPE

DRIP LEG OR EQUIPMENT

CONNECTION. MAKE THE SAME

SIZE AS THE SUPPLY MAIN OR

EQUIPMENT CONNECTION. SEE

NOTE 1

SCHEDULE 80 STEEL PIPE

SEE DRAWINGS FOR PIPE

SIZES

25mm [1"]

GATE VALVE

USE 4-BOLT RAISED FACE FLANGES

m m m m

[1

M

IN

[6

M

IN

TO DRAIN

MV

MANUAL

AIR VENT

TO BUILDING

LOAD

INVERTED

BUCKET

TRAP ASSEMBLYWELDED TEE

SCHEDULE 80 STEEL

PIPE

25mm [1"] GATE VALVE

WELDED TEE

CONDENSATE

STEAM PIPE

300mm[12"]

150mm[6"]

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:0

:1

P M

M-301

MECHANICAL DETAILS

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

NO SCALE

PIPE HANGERS DETAIL

1 NO SCALE

CONCRETE EQUIPMENT BASES

NO SCALE

BOILER BLOW DOWN SEPARATOR

NO SCALE

TYP. CONNECTIONS TO FLASH TANK

NO SCALE

STEAM PRESS. RED. STATION DOUBLE VALVE 1/3 & 2/3

5 NO SCALE

INVERTED BUCKET STEAM TRAP ASSY.

6 NO SCALE

FLOAT & THERMOSTATIC STEAM TRAP ASSY.

NO SCALE

THERMOSTATIC STEAM TRAP ASSY.

8 NO SCALE

END OF LINE STEAM TRAP

STEAM TRAP ASSEMBLY

STEAM LINE DRIP POCKET

DRIP LEG (TYP.)

20mm [3/4"] DRAIN

(ALTERNATE LOCATIONS)

(TYPICAL)

STEAM LINE

(TYPICAL)

CAP (TYPICAL)

PIPE T0 STEAM

TRAP (TYPICAL)

NOTE:

DRIP POCKET PIPE SIZE SAME AS

STEAM MAIN UNLESS OTHERWISE

NOTED.

20mm [3/4"] MIN.

FROM DRIP

CONNECTION

DRIP

RETURN

10mm [3/8"] TEST

CONNECTION

m m [6

M

IN

m m

[1 m m [6

M

IN

[1

M

IN

m m

V T

R

BO

HPR

CW

CW

32mm [1 1/4"]

OFL

FULL

CIRCUMFERENCE

WEAR PLATE

PLAN VIEW

LEG (4 REQD.)

HPR

BO

C W

50mm [2"]

PLUGGED

COUPLING

(TYP)

WEAR PLATE

TEMPERATURE

CONTROL

VALVE (TCV-1)

32mm [1 1/4"]

20mm [3/4"]

THERMAL BULB

50mm [2"]

PIPE SIZE IN

AREA OF

THERMAL

BULB

0-150°C

[30-300°F] (TYP)

WELL

CROSS

OFL

FROM STEAM ATOMIZING

BURNER AND OIL HEATER

TRAPS

0-200 kPa [0-30 PSIG]

FROM BOILERS

GAUGE GLASS (25mm [1/2"] MIN.DIA)

INTERNAL OFL PIPE (WATER SEAL)

STEEL

ANGLES GROUT

PLUGS

ELEVATION

NOTE:

TANK SHALL BE MANUFACTURED AND

FURNISHED IN ACCORDANCE WITH

THE ASME BOILER AND PRESSURE

VESSEL CODE AND AMERICAN

NATIONAL STANDARD ANSI/ASME BPV

VIII-1. INSPECTION AND

REGISTRATION ARE WITH THE

NATIONAL BOARD OF BOILER AND

PRESSURE VESSEL INSPECTORS

20mm [3/4"]

OPENING

(SYPHON

BREAKER)

50mm [2"] DRAIN

FINISHED

FLOOR

PLATE

OPEN SIGHT DRAIN

MANHOLE 305x406mm [12"x16"]

32mm [1 1/4"]

NC

C

305mm [12"]

ALIGN WITH CENTER OF WEAR

PLATE

L TANK (NORMAL WATER LEVEL)

152mm [6"]

152mm [6"]

152mm [6"] m

1/2" ALL AROUND

1" X 1/8" X LENTH OF

SLEEVE (4 REQ'D)

PIPE SLEEVE 2"

LARGER I.D.

THAN PIPE O.D.

AS REQUIRED

FOR DIFFERENT

PIPE SIZES

6 GA. SHEET

METAL (GALV.)

FLASHING COLLAR

FLASHING &

COUNTER FLASHING

ROOF

WELD (TYP)

WELD TO VENT

INSULATION

WHERE REQUIRED

FLASHING AND COUNTER

VENT STORM COLLAR

RAIN CAP

7'-0" ABOVE ROOF

DOUBLE WALL POSITIVE

PRESSURE TYPE

SMOKE STACK

19-1/4" INSIDE DIA. STACK

FROM BOILERS.

SPRING VIBRATION

ISOLATORS

YOKE END FORGED

STEEL CLEVIS HANGER

FORGED STEEL

THREADED TURNBUCKEL

WITH ALL THREAD ROD

ROOF SUPPORT

ASSEMBLY

PRIME AND PAINT. REFER TO SPECIFICATION

SECTION. NTS: EDIT SECTION BASED ON

WHICH CONTRACTOR IS RESPONSIBLE FOR

EXHAUST PIPING.

PROVIDE GAP FOR VERTICAL

EXPANSION OF PIPE.

18 GA. RADIANT

DEFLECTOR NOTE 1

PERFORATE RADIANT

DEFLECTOR SUPPORT RING

TO ALLOW AIR FLOW PAST.

RAIN HOOD

(18 GA. GALV. STEEL)

PREFABRICATED CURB WITH

WOOD NAILER.

FASTEN COUNTER

FLASHING TO CURB WITH

CADMIUM PLATED SCREWS.

CARRY ROOFING UP UNDER

COUNTER FLASHING.

INSULATION

CONCRETE ROOF DECK

PIPE ANCHORS BY H.C. AT 120̊ SPACING.

CONTINUOUS WELD TO PIPE SLEEVE.

LONG SWEEP ELBOW

3/4" DRAIN LINE WITH NORMALLY CLOSED

DRAIN VALVE - PIPE TO FLOOR DRAIN

EXHAUST PIPE TO SILENCER

PIPE SUPPORT

METAL

ROOF DECK

CAP HEIGHT 12"

ABOVE ROOF DECK

6”

A P

P R

O X

STAINLESS STEEL BIRD

SCREEN WELDED TO PIPE

OPENING.

CUT END AT 45°

WELD RAIN HOOD CAP TO

STACK (CONTINUAL WELD

TO MAKE WATER TIGHT)

3" HIGH TEMPERATURE

FIBERBOARD INSULATION.

BIRD SCREEN (NOT

ATTACHED TO ROOF

CURB).

6”3”

NOTES:

1. RADIANT DEFLECTOR RING SHALL BE EXTENDED 6" ABOVE

INSULATED ROOF CURB AND 6" BELOW ROOF DECK.

OUTSIDE WALL

PIPE TO FLOOR DRAIN.

FLEX CONNECTION

BYPASS MOTORIZED

DAMPER (NEW)

MOTORIZED

DAMPER (NEW)

EXISTING EXHAUST AIR

LOUVER

DUCTWORK

FLEX CONNECTION AND

ISOLATION VALVE REQUIRED ON

FUEL PIPING

EMERGENCY GENERATOR

3/4"

LONG SWEEP ELBOW

LABELED DRAIN VALVE

(NORMALLY CLOSED).

RADIATOR WITH GEN SET

VIBRATION ISOLATORS BY M.C. (TYPICAL)

FURNISH AND INSTALL SADDLE TYPE

SUPPORTS TRAPEZE HANGERS, AND

STRUCTURAL STEEL ROOF

ATTACHMENT (I.E. BEAM CLAMPS).

(TYPICAL)

FURNISH AND PROVIDE NEW

SILENCERPIPE SUPPORTS 5' O.C. AND AT

CHANGE OF DIRECTION (TYP.)

EXHAUST PIPE PITCHED AWAY

FROM ENGINE

EXHAUST PIPING

FLEXIBLE PIPE CONNECTION

VIBRATION ISOLATION BASE

EXISTING

INTAKE HOOD

NEW MOTORIZED

DAMPER

REFER TO DETAIL 5/M302 FOR

EXHAUST PIPE INSTALLATION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Shaffer & Stevens 9910 North 48th Street

Omaha, Nebraska68152

Phone: 402.455.7698 Fax: 402.455.7597

504-18-119

AMI Environmental Inc

8802 S 135th Street

Omaha, NE 68138

Phone:(402) 397-5001

IMEG Corp.

14755 Preston Rd., Suite 845

Dallas, TX 75254

Phone:(972) 239-6100

15% Design Submission 07/14/2020

20% Design Submission

30% Design Submission

35%/SD1 Schematic Design Submission

09/08/2020

08/14/2020

11/17/2020

FOR REFERENCE

ONLY NOT FOR

CONSTRUCTION

C R e v it L o c a l F ile s \M

E

.0

A m a ri llo B o ile r R e p la c e m e n t_ C d e ta c h e d

P a u l.

W

.L ic h te n h a n .r v t

/1 /2

:5

:0

P M

M-302

MECHANICAL DETAILS

November 17, 2020

Replace Boilers and PipingSD-1 35% SUBMITTAL

REQUEST FOR PROPOSAL

Thomas E. Creek VAMC-Amarillo, TX

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.

14755 PRESTON ROAD, SUITE 845

DALLAS, TX 75254

972.239.6100 FAX: 972.239.6102

www.imegcorp.com

TBPE# F-18632

20001967.00

NO SCALE

STEAM DRIP POCKET AND TRAP ASSEMBLY

2 NO SCALE

BOILER BLOWDOWN SEPARATOR TANK

3 NO SCALE

HOT VENT THROUGH ROOF

4NO SCALE

BOILER STACK DETAIL

NO SCALE

GENERATOR EXHAUST PIPE ROOF PENETRATION

5 NO SCALE

GENERATOR INSTALLATION DETAIL - ADD ALTERNATE