JL-1_N6945026R0007_Labor Hours Spreadsheet.xlsx
XLSX spreadsheet 37 KB Posted
- Attached to
- Base Operations Support (BOS) Services at Naval Air Station (NAS) Jacksonville, FL and Outlying Areas
- Solicitation number
- N6945026R0007
About this file
This file is a Labor Hours Spreadsheet for a Base Operations Support (BOS) Services contract (Solicitation Number: N6945026R0007) for Naval Air Station Jacksonville and outlying areas. The spreadsheet details a comprehensive list of recurring work and services across multiple facility categories, including Facility Management, Facility Investment, Utilities Management, Transportation, and Environmental services. The contract covers 18 primary work areas (CLINs) for various commands and facilities such as 81st Regional Support Center, CNRSE, Defense Health Agency, Defense Logistics Agency, Fleet Readiness Center Southeast, Naval Supply, and others.
The contract includes extensive labor hour allocations for specific tasks like preventive maintenance, equipment inspections, utility operations, vehicle maintenance, and environmental services. Key service categories include E/U/R (Engineering/Utility/Repair) Work, Preventive Maintenance Programs, Inspection/Testing/Certification Programs, and Other Recurring Services across systems like HVAC, electrical, fire protection, transportation equipment, and utility infrastructure. The contract is structured with a base period of one year and potential for seven additional one-year option periods, totaling a maximum of eight years, with the primary NAICS Code 561210 and a small business size standard of $47.0 million.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JL-1
| Base Period JL-1 Sheet |
| Solicitation/Contract No.: N69450-26-R-0007 |
| CLIN 0001 - Recurring Work - Base Period | |||||||||
| Provide Prices for Recurring Work in accordance with Section C, Spec Item 3 | |||||||||
| ELINs A001 through A018 | |||||||||
| Customer | Category | Sub-Category | ELIN | Sub-ELIN | Annex/Sub-annex | Spec Item | Description | Spec Item 3 | |
| Labor Hours | Annex 0200000 and Functional Annexes' Spec Items 1 and 2 |
On-Site
| Labor Hours | Total Labor Hours Spec Items 1, 2 & 3 | |||||||
| 81st Regional Support Center | Facility Investment | Preventive Maintenance Program | A001 | A001AA | 1502000 | 3.2.6 | Doors and Gate Systems | |
| 81st Regional Support Center | Facility Investment | Preventive Maintenance Program | A001 | A001AB | 1502000 | 3.2.7 | Fire Protection Systems | |
| 81st Regional Support Center | Facility Investment | Preventive Maintenance Program | A001 | A001AC | 1502000 | 3.2.11 | HVAC and Refrigeration Systems | |
| 81st Regional Support Center | Facility Investment | Preventive Maintenance Program | A001 | A001AD | 1502000 | 3.2.14 | Unfired Pressure Vessels (UPVs) | |
| 81st Regional Support Center | Facility Investment | Preventive Maintenance Program | A001 | A001AE | 1502000 | 3.2.16 | Ventilation Systems | |
| 81st Regional Support Center | Facility Investment | Other Recurring Services Program | A001 | A001AF | 1502000 | 3.4.3 | Fuel/Oil Storage Tanks and Berms | |
| 81st Regional Support Center | Facility Investment | Other Recurring Services Program | A001 | A001AG | 1502000 | 3.4.7 | Lighting Systems | |
| 81st Regional Support Center | Facility Investment | Other Recurring Services Program | A001 | A001AH | 1502000 | 3.4.9 | Oily Water Separators | |
| 81st Regional Support Center | Facility Investment | Other Recurring Services Program | A001 | A001AJ | 1502000 | 3.4.12 | Drinking Fountains & Water Coolers | |
| CNRSE | Facility Management | Recurring Work | A002 | A002AA | 1501000 | 3.1 | NAVFAC MAXIMO Data Entry | |
| CNRSE | Facility Management | Recurring Work | A002 | A002AB | 1501000 | 3.2 | Infrastructure Condition Assessment Program (ICAP) Services | |
| CNRSE | Facility Management | Recurring Work | A002 | A002AC | 1501000 | 3.3 | Technical Support Services | |
| CNRSE | Facility Investment | E/U/R Work | A002 | A002AD | 1502000 | 3.1 | E/U/R Work - 5000 EA | |
| CNRSE | Facility Investment | E/U/R Work | A002 | A002AE | 1502000 | 3.1.2 | Emergency-Unaccompanied Housing (UH) - 160 EA | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AF | 1502000 | 3.2.1 | Aircraft Rinse Facility | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AG | 1502000 | 3.2.2 | Airfield Lighting Systems | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AH | 1502000 | 3.2.3 | Auxiliary Generators | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AJ | 1502000 | 3.2.4 | Boiler Systems | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AK | 1502000 | 3.2.5 | Compressed Air Systems | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AL | 1502000 | 3.2.6 | Door and Gate Systems | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AM | 1502000 | 3.2.7 | Fire Protection Systems | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AN | 1502000 | 3.2.8 | Frequency Converters (400HZ) Systems | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AP | 1502000 | 3.2.9 | Galley Equipment and Systems | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AQ | 1502000 | 3.2.10 | Hangar Door Systems – Mega Door | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AR | 1502000 | 3.2.11 | HVAC and Refrigeration Systems | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AS | 1502000 | 3.2.13 | Truck Scale | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AT | 1502000 | 3.2.14 | Unfired Pressure Vessels (UPVs) | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AU | 1502000 | 3.2.15 | Uninterruptible Power Supplies (UPS) | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AV | 1502000 | 3.2.16 | Ventilation Systems | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AW | 1502000 | 3.2.17 | Vertical Transportation Equipment (VTE) | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AX | 1502000 | 3.2.18 | Facility Mounted Weight Handling Equipment (WHE) | |
| CNRSE | Facility Investment | Preventive Maintenance Program | A002 | A002AY | 1502000 | 3.2.19 | Wash Rack | |
| CNRSE | Facility Investment | Inspection, Testing, and Certification Program | A002 | A002AZ | 1502000 | 3.3.1 | Backflow Prevention Devices | |
| CNRSE | Facility Investment | Inspection, Testing, and Certification Program | A002 | A002BA | 1502000 | 3.3.2 | Boilers and UPVs | |
| CNRSE | Facility Investment | Inspection, Testing, and Certification Program | A002 | A002BB | 1502000 | 3.3.3 | Condenser Tube Inspection | |
| CNRSE | Facility Investment | Inspection, Testing, and Certification Program | A002 | A002BC | 1502000 | 3.3.4 | Grounding Points and Grounding Systems | |
| CNRSE | Facility Investment | Inspection, Testing, and Certification Program | A002 | A002BD | 1502000 | 3.3.7 | Truck Scale | |
| CNRSE | Facility Investment | Inspection, Testing, and Certification Program | A002 | A002BE | 1502000 | 3.3.8 | Vertical Transportation Equipment (VTE) | |
| CNRSE | Facility Investment | Inspection, Testing, and Certification Program | A002 | A002BF | 1502000 | 3.3.9 | Facility Mounted Weight Handling Equipment (WHE) | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BG | 1502000 | 3.4.1 | Boiler Water Testing and Treatment Services | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BH | 1502000 | 3.4.2 | Exhaust Hoods and Ducts Systems | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BJ | 1502000 | 3.4.3 | Fuel/Oil Storage Tanks and Berms | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BK | 1502000 | 3.4.4 | Grease Traps and Grit Traps | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BL | 1502000 | 3.4.5 | HVAC Seasonal Start-Up and Shutdown | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BM | 1502000 | 3.4.6 | HVAC Water Testing and Treatment Services | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BN | 1502000 | 3.4.7 | Lighting Systems | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BP | 1502000 | 3.4.8 | Lint Traps | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BQ | 1502000 | 3.4.9 | Oily Water Separators | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BR | 1502000 | 3.4.10 | Process Water Treatment | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BS | 1502000 | 3.4.11 | Septic Systems | |
| CNRSE | Facility Investment | Other Recurring Services Program | A002 | A002BT | 1502000 | 3.4.12 | Drinking Fountains/Water Coolers | |
| CNRSE | Other (Training) Pools | Recurring Work | A002 | A002BU | 1503040 | 3.1 | Pool Operator Maintenance | |
| CNRSE | Other (Training) Pools | Recurring Work | A002 | A002BV | 1503040 | 3.1.1 | Water Treatment | |
| CNRSE | Other (Training) Pools | Operations | A002 | A002BW | 1503040 | 3.2 | Operations | |
| CNRSE | Other (Training) Pools | Preventive Maintenance Program | A002 | A002BX | 1503040 | 3.3 | Preventive Maintenance | |
| CNRSE | Base Support Vehicles and Equipment (BSVE) | Support Services | A002 | A002BY | 1700000 | 3.1.1 | Dispatch Services - 440 Annually | |
| CNRSE | Base Support Vehicles and Equipment (BSVE) | Support Services | A002 | A002BZ | 1700000 | 3.1.2 | GSA Leased Vehicles | |
| CNRSE | Base Support Vehicles and Equipment (BSVE) | Maintenance of Non-Tactical Vehicles and Equipment (NTVE) | A002 | A002CA | 1700000 | 3.2 | Maintenance of Non-Tactical Vehicles and Equipment (NTVE) | |
| CNRSE | Base Support Vehicles and Equipment (BSVE) | NTVE Trouble Calls | A002 | A002CB | 1700000 | 3.2.1.5 | NTVE Trouble Calls - 150 each | |
| CNRSE | Base Support Vehicles and Equipment (BSVE) | NTVE Accessories Installation and Removal | A002 | A002CC | 1700000 | 3.3 | NTVE Accessories Installation and Removal | |
| CNRSE Environmental | Environmental | Oil/Regulated Substance Spill Response and Cleanup Ashore | A003 | A003AA | 1800000 | 3.1 | Oil and Regulated Substance Spill Response and Cleanup Ashore | |
| Defense Health Agency (DHA) | Facility Investment | E/U/R Work | A004 | A004AA | 1502000 | 3.1 | E/U/R Work | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AB | 1502000 | 3.2.1 | Boiler and UPVs Systems & Equipment | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AC | 1502000 | 3.2.2 | Compressed Air Systems | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AD | 1502000 | 3.2.3 | Emergency Generator Systems | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AE | 1502000 | 3.2.4 | Fire Protection Systems | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AF | 1502000 | 3.2.5 | Food Service Equipment | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AG | 1502000 | 3.2.6 | General Equipment | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AH | 1502000 | 3.2.7 | HVAC and Refrigeration Systems | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AJ | 1502000 | 3.2.9 | Isolation Rooms, Operating Rooms & Clean Rooms | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AK | 1502000 | 3.2.10 | Lightning Arrestors and Grounding Devices | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AL | 1502000 | 3.2.11 | Nurse Call Station and Infant Alarms | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AM | 1502000 | 3.2.12 | Public Address System (PA) | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AN | 1502000 | 3.2.13 | Security Systems and Equipment | |
| Defense Health Agency (DHA) | Facility Investment | Preventive Maintenance Program | A004 | A004AP | 1502000 | 3.2.14 | Vertical Transportation Equipment (VTE) | |
| Defense Health Agency (DHA) | Facility Investment | Inspection, Testing, and Certification Program | A004 | A004AQ | 1502000 | 3.3.1 | Backflow Prevention Devices | |
| Defense Health Agency (DHA) | Facility Investment | Inspection, Testing, and Certification Program | A004 | A004AR | 1502000 | 3.3.2 | Boilers and UPVs | |
| Defense Health Agency (DHA) | Facility Investment | Inspection, Testing, and Certification Program | A004 | A004AS | 1502000 | 3.3.3 | Crawlspace Inspections | |
| Defense Health Agency (DHA) | Facility Investment | Inspection, Testing, and Certification Program | A004 | A004AT | 1502000 | 3.3.4 | Roof Inspection & Cleaning | |
| Defense Health Agency (DHA) | Facility Investment | Inspection, Testing, and Certification Program | A004 | A004AU | 1502000 | 3.3.5 | Vertical Transportation Equipment (VTE) | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004AV | 1502000 | 3.4.1 | Boiler Water Testing and Treatment Services | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004AW | 1502000 | 3.4.2 | Duty Crew Requirements | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004AX | 1502000 | 3.4.3 | Electrical Receptacles | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004AY | 1502000 | 3.4.4 | Electrical Transformers, Breakers and Switches | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004AZ | 1502000 | 3.4.5 | Exhaust Fans, Exhaust Hoods and Ducts | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004BA | 1502000 | 3.4.6 | Freeze Protection | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004BB | 1502000 | 3.4.7 | Fuel Storage Tanks and Berms | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004BC | 1502000 | 3.4.8 | Grease Traps and Plaster Traps | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004BD | 1502000 | 3.4.9 | HVAC Water Testing and Treatment Services | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004BE | 1502000 | 3.4.10 | Interior and Exterior Lighting Systems | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004BF | 1502000 | 3.4.11 | Locksmith Services | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004BG | 1502000 | 3.4.12 | Medical Gas Systems | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004BH | 1502000 | 3.4.13 | Public Address System | |
| Defense Health Agency (DHA) | Facility Investment | Other Recurring Services Program | A004 | A004BJ | 1502000 | 3.4.14 | Visual and Audible Check on HVAC Systems | |
| Defense Health Agency (DHA) | Transportation | Maintenance of Non-Tactical Vehicles and Equipment (NTVE) | A004 | A004BK | 1700000 | 3.2 | Maintenance of Non-Tactical Vehicles and Equipment (NTVE) | |
| Defense Health Agency (DHA) | Transportation | Maintenance of Non-Tactical Vehicles and Equipment (NTVE) | A004 | A004BL | 1700000 | 3.3 | NTVE Accessories Installation and Removal | |
| Defense Health Agency (DHA) | Environmental | Oil/Regulated Substance Spill Response and Cleanup Ashore | A004 | A004BM | 1800000 | 3.1 | Oil and Regulated Substance Spill Response and Cleanup Ashore | |
| Defense Logistics Agency (DLA) – Aviation | Facility Investment | E/U/R Work | A005 | A005AA | 1502000 | 3.1 | E/U/R Work - 50 EA | |
| Defense Logistics Agency (DLA) – Defense Energy Support Center | Facility Investment | E/U/R Work | A006 | A006AA | 1502000 | 3.1 | E/U/R Work - 86 EA | |
| Defense Logistics Agency (DLA) – Defense Energy Support Center | Facility Investment | Preventive Maintenance Program | A006 | A006AB | 1502000 | 3.2.5 | Compressed Air Systems | |
| Defense Logistics Agency (DLA) – Defense Energy Support Center | Facility Investment | Preventive Maintenance Program | A006 | A006AC | 1502000 | 3.2.7 | Fire Protection Systems | |
| Defense Logistics Agency (DLA) – Defense Energy Support Center | Facility Investment | Preventive Maintenance Program | A006 | A006AD | 1502000 | 3.2.12 | Self-Retracting Lifelines (SRL) and Trolleys | |
| Defense Logistics Agency (DLA) – Defense Energy Support Center | Facility Investment | Inspection, Testing, and Certification Program | A006 | A006AE | 1502000 | 3.3.4 | Grounding Points and Grounding Systems | |
| Defense Logistics Agency (DLA) – Defense Energy Support Center | Facility Investment | Inspection, Testing, and Certification Program | A006 | A006AF | 1502000 | 3.3.6 | Self-Retracting Lifelines (SRL), Horizontal Lifelines (HLL), and Trolleys | |
| Defense Logistics Agency (DLA) – Defense Energy Support Center | Facility Investment | Other Recurring Services Program | A006 | A006AG | 1502000 | 3.4.7 | Lighting Systems | |
| Defense Logistics Agency (DLA) – Defense Energy Support Center | Facility Investment | Other Recurring Services Program | A006 | A006AH | 1502000 | 3.4.9 | Oily Water Separators | |
| Defense Logistics Agency (DLA) – Disposition | Facility Investment | E/U/R Work | A007 | A007AA | 1502000 | 3.1 | E/U/R Work - 146 EA | |
| Defense Logistics Agency (DLA) – Disposition | Facility Investment | Preventive Maintenance Program | A007 | A007AB | 1502000 | 3.2.6 | Door and Gate Systems | |
| Defense Logistics Agency (DLA) – Disposition | Facility Investment | Preventive Maintenance Program | A007 | A007AC | 1502000 | 3.2.7 | Fire Protection Systems | |
| Defense Logistics Agency (DLA) – Disposition | Facility Investment | Preventive Maintenance Program | A007 | A007AD | 1502000 | 3.2.11 | HVAC and Refrigeration Systems | |
| Defense Logistics Agency (DLA) – Disposition | Facility Investment | Other Recurring Services Program | A007 | A007AE | 1502000 | 3.4.12 | Drinking Fountains & Water Coolers | |
| Defense Logistics Agency (DLA) - Distribution | Facility Investment | E/U/R Work | A008 | A008AA | 1502000 | 3.1 | E/U/R Work - 174 EA | |
| Defense Logistics Agency (DLA) - Distribution | Facility Investment | Preventive Maintenance Program | A008 | A008AB | 1502000 | 3.2.6 | Door and Gate Systems | |
| Defense Logistics Agency (DLA) - Distribution | Facility Investment | Preventive Maintenance Program | A008 | A008AC | 1502000 | 3.2.7 | Fire Protection Systems | |
| Defense Logistics Agency (DLA) - Distribution | Facility Investment | Preventive Maintenance Program | A008 | A008AD | 1502000 | 3.2.11 | HVAC and Refrigeration Systems | |
| Defense Logistics Agency (DLA) - Distribution | Facility Investment | Inspection, Testing, and Certification Program | A008 | A008AE | 1502000 | 3.3.1 | Backflow Prevention Devices | |
| Defense Logistics Agency (DLA) - Distribution | Facility Investment | Inspection, Testing, and Certification Program | A008 | A008AF | 1502000 | 3.3.4 | Grounding Points and Grounding Systems | |
| Defense Logistics Agency (DLA) - Distribution | Facility Investment | Other Recurring Services Program | A008 | A008AG | 1502000 | 3.4.3 | Fuel/Oil Storage Tanks and Berms | |
| Defense Logistics Agency (DLA) - Distribution | Facility Investment | Other Recurring Services Program | A008 | A008AH | 1502000 | 3.4.5 | HVAC Seasonal Start-Up and Shutdown | |
| Defense Logistics Agency (DLA) - Distribution | Facility Investment | Other Recurring Services Program | A008 | A008AJ | 1502000 | 3.4.7 | Lighting Systems | |
| Defense Logistics Agency (DLA) - Distribution | Facility Investment | Other Recurring Services Program | A008 | A008AK | 1502000 | 3.4.12 | Drinking Fountains & Water Coolers | |
| Document Automation and Production Service (DAPS) | Facility Investment | E/U/R Work | A009 | A009AA | 1502000 | 3.1 | E/U/R Work - 12 EA | |
| Document Automation and Production Service (DAPS) | Facility Investment | Preventive Maintenance Program | A009 | A009AB | 1502000 | 3.2.3 | Auxiliary Generators | |
| Document Automation and Production Service (DAPS) | Facility Investment | Preventive Maintenance Program | A009 | A009AC | 1502000 | 3.2.4 | Boiler Systems | |
| Document Automation and Production Service (DAPS) | Facility Investment | Preventive Maintenance Program | A009 | A009AD | 1502000 | 3.2.7 | Fire Protection Systems | |
| Document Automation and Production Service (DAPS) | Facility Investment | Preventive Maintenance Program | A009 | A009AE | 1502000 | 3.2.11 | HVAC and Refrigeration Systems | |
| Document Automation and Production Service (DAPS) | Facility Investment | Preventive Maintenance Program | A009 | A009AF | 1502000 | 3.2.16 | Ventilation Systems | |
| Document Automation and Production Service (DAPS) | Facility Investment | Inspection, Testing, and Certification Program | A009 | A009AG | 1502000 | 3.3.1 | Backflow Prevention Devices | |
| Document Automation and Production Service (DAPS) | Facility Investment | Inspection, Testing, and Certification Program | A009 | A009AH | 1502000 | 3.3.2 | Boilers and UPVs | |
| Document Automation and Production Service (DAPS) | Facility Investment | Other Recurring Services Program | A009 | A009AJ | 1502000 | 3.4.1 | Boiler Water Testing and Treatment Services | |
| Document Automation and Production Service (DAPS) | Facility Investment | Other Recurring Services Program | A009 | A009AK | 1502000 | 3.4.5 | HVAC Seasonal Start-Up and Shutdown | |
| Document Automation and Production Service (DAPS) | Facility Investment | Other Recurring Services Program | A009 | A009AL | 1502000 | 3.4.7 | Lighting Systems | |
| Family Housing | Facility Investment | E/U/R Work | A010 | A010AA | 1502000 | 3.1 | E/U/R Work - 16 EA | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | E/U/R Work | A011 | A011AA | 1502000 | 3.1.1 | E/U/R Work - 1900 EA | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Preventive Maintenance Program | A011 | A011AB | 1502000 | 3.2.4 | Boiler Systems | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Preventive Maintenance Program | A011 | A011AC | 1502000 | 3.2.5 | Compressed Air Systems | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Preventive Maintenance Program | A011 | A011AD | 1502000 | 3.2.6 | Door and Gate Systems | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Preventive Maintenance Program | A011 | A011AE | 1502000 | 3.2.7 | Fire Protection Systems | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Preventive Maintenance Program | A011 | A011AF | 1502000 | 3.2.11 | HVAC and Refrigeration Systems | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Preventive Maintenance Program | A011 | A011AG | 1502000 | 3.2.12 | Self-Retracting Lifelines (SRL) and Trolleys | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Preventive Maintenance Program | A011 | A011AH | 1502000 | 3.2.14 | Unfired Pressure Vessels (UPVs) | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Preventive Maintenance Program | A011 | A011AJ | 1502000 | 3.2.16 | Ventilation Systems | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Preventive Maintenance Program | A011 | A011AK | 1502000 | 3.2.17 | Vertical Transportation Equipment (VTE) | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Preventive Maintenance Program | A011 | A011AL | 1502000 | 3.2.18 | Facility Mounted Weight Handling Equipment (WHE) | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Inspection, Testing, and Certification Program | A011 | A011AM | 1502000 | 3.3.1 | Backflow Prevention Devices | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Inspection, Testing, and Certification Program | A011 | A011AN | 1502000 | 3.3.2 | Boilers and UPVs | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Inspection, Testing, and Certification Program | A011 | A011AP | 1502000 | 3.3.3 | Condenser Tube Inspection | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Inspection, Testing, and Certification Program | A011 | A011AQ | 1502000 | 3.3.4 | Grounding Points and Grounding Systems | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Inspection, Testing, and Certification Program | A011 | A011AR | 1502000 | 3.3.5 | Roof Inspection and Cleaning | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Inspection, Testing, and Certification Program | A011 | A011AS | 1502000 | 3.3.6 | Self-Retracting Lifelines (SRL) and Trolleys | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Inspection, Testing, and Certification Program | A011 | A011AT | 1502000 | 3.3.8 | Vertical Transportation Equipment (VTE) | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Inspection, Testing, and Certification Program | A011 | A011AU | 1502000 | 3.3.9 | Facility Mounted Weight Handling Equipment (WHE) | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Other Recurring Services Program | A011 | A011AV | 1502000 | 3.4.1 | Boiler Water Testing and Treatment Services | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Other Recurring Services Program | A011 | A011AW | 1502000 | 3.4.2 | Exhaust Hoods and Ducts Systems | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Other Recurring Services Program | A011 | A011AX | 1502000 | 3.4.3 | Fuel/Oil Storage Tanks and Berms | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Other Recurring Services Program | A011 | A011AY | 1502000 | 3.4.5 | HVAC Seasonal Start-Up and Shutdown | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Other Recurring Services Program | A011 | A011AZ | 1502000 | 3.4.6 | HVAC Water Testing and Treatment Services | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Other Recurring Services Program | A011 | A011BA | 1502000 | 3.4.7 | Lighting Systems | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Other Recurring Services Program | A011 | A011BB | 1502000 | 3.4.9 | Oily Water Separators | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Other Recurring Services Program | A011 | A011BC | 1502000 | 3.4.10 | Process Water Treatment | |
| Fleet Readiness Center Southeast (FRCSE) | Facility Investment | Other Recurring Services Program | A011 | A011BD | 1502000 | 3.4.12 | Drinking Fountains & Water Coolers | |
| Fleet Readiness Center Southeast (FRCSE) | Transportation | Maintenance of Non-Tactical Vehicles and Equipment (NTVE) | A011 | A011BE | 1700000 | 3.2 | Maintenance of Non-Tactical Vehicles and Equipment (NTVE) | |
| Fleet Readiness Center Southeast (FRCSE) | Transportation | NTVE Accessories Installation and Removal | A011 | A011BF | 1700000 | 3.3 | NTVE Accessories Installation and Removal | |
| Fleet Readiness Center Southeast (FRCSE) | Environmental | Oil/Regulated Substance Spill Response and Cleanup Ashore | A011 | A011BG | 1800000 | 3.1 | Oil and Regulated Substance Spill Response and Cleanup Ashore | |
| Fleet Readiness Center Southeast (FRCSE) | Environmental | Cleaning and Inspection Services | A011 | A011BH | 1800000 | 3.2 | Cleaning and Inspection Services | |
| Housing Learning Center | Facility Investment | E/U/R Work | A012 | A012AA | 1502000 | 3.1 | E/U/R Work - 30 EA | |
| Housing Learning Center | Facility Investment | Preventive Maintenance Program | A012 | A012AB | 1502000 | 3.2.7 | Fire Protection Systems | |
| Housing Learning Center | Facility Investment | Preventive Maintenance Program | A012 | A012AC | 1502000 | 3.2.11 | HVAC and Refrigeration Systems | |
| Housing Learning Center | Facility Investment | Preventive Maintenance Program | A012 | A012AD | 1502000 | 3.4.7 | Lighting Systems | |
| Morale, Welfare and Recreation (MWR) | Facility Investment | E/U/R Work | A013 | A013AA | 1502000 | 3.1 | E/U/R Work - 10 EA | |
| CNRSE | Utilities Management | Utility E/U/R Work | A014 | A014AA | 1601000 | 3.1 | Utility E/U/R Work - 144 EA | |
| CNRSE | Utilities Management | Utility Operations Management | A014 | A014AB | 1601000 | 3.2 | Utility Operations Management | |
| CNRSE | Utilities Management | Utility Infrastructure Condition Assessment (UICAP) Support | A014 | A014AC | 1601000 | 3.3 | Utility Infrastructure Condition Assessment (UICAP) Support | |
| CNRSE | Utilities Management | NAVFAC Maximo Data Entry | A014 | A014AD | 1601000 | 3.4 | NAVFAC Maximo Data Entry | |
| CNRSE | Electrical | Operate Electrical Power Distribution Systems | A014 | A014AE | 1602000 | 3.1 | Operate Electrical Power Transmission and Distribution Systems | |
| CNRSE | Electrical | Preventive Maintenance | A014 | A014AF | 1602000 | 3.2 | Preventive Maintenance | |
| CNRSE | Electrical | Other Recurring Services Program | A014 | A014AG | 1602000 | 3.3 | Other Recurring Services | |
| CNRSE | Electrical | Other Recurring Services Program | A014 | A014AH | 1602000 | 3.4 | Utility Right of Way Clearance | |
| CNRSE | Wastewater | Operation | A014 | A014AJ | 1604000 | 3.1 | Operation - 24/7 Requirement | |
| CNRSE | Wastewater | Preventive Maintenance | A014 | A014AK | 1604000 | 3.2 | Preventive Maintenance | |
| CNRSE | Steam | Operation | A014 | A014AL | 1605000 | 3.1 | Operation - 24/7 Requirement | |
| CNRSE | Steam | Preventive Maintenance | A014 | A014AM | 1605000 | 3.2 | Preventive Maintenance | |
| CNRSE | Steam | Inspection, Testing, and Certification Program | A014 | A014AN | 1605000 | 3.3 | Inspection, Testing, and Certification Program | |
| CNRSE | Steam | Other Recurring Services Program | A014 | A014AP | 1605000 | 3.4 | Other Recurring Services | |
| CNRSE | Water | Operation | A014 | A014AQ | 1606000 | 3.1 | Operation - 8 hours a day, 4 hours on weekend & holidays | |
| CNRSE | Water | Preventive Maintenance | A014 | A014AR | 1606000 | 3.2 | Preventive Maintenance | |
| CNRSE | Water | Inspection, Testing, and Certification Program | A014 | A014AS | 1606000 | 3.3 | Inspection, Testing, and Certification Program | |
| CNRSE | Water | Other Recurring Services Program | A014 | A014AT | 1606000 | 3.4 | Other Recurring Services | |
| CNRSE | Compressed Air | Operation | A014 | A014AU | 1608000 | 3.1 | Operation - Check every 2 hours approx. 15 minutes each visit | |
| CNRSE | Compressed Air | Preventive Maintenance | A014 | A014AV | 1608000 | 3.2 | Preventive Maintenance | |
| CNRSE | Compressed Air | Inspection, Testing, and Certification Program | A014 | A014AW | 1608000 | 3.3 | Inspection, Testing, and Certification Program | |
| CNRSE | Compressed Air | Other Recurring Services Program | A014 | A014AX | 1608000 | 3.4 | Other Recurring Services | |
| Naval Supply (NAVSUP) Fleet Logistics Center Jacksonville (FLCJ) | Facility Investment | E/U/R Work | A015 | A015AA | 1502000 | 3.1 | E/U/R Work - 140 EA | |
| Naval Supply (NAVSUP) Fleet Logistics Center Jacksonville (FLCJ) | Transportation | Maintenance of Non-Tactical Vehicles and Equipment (NTVE) | A015 | A015AB | 1700000 | 3.2 | Maintenance of Non-Tactical Vehicles and Equipment (NTVE) | |
| Naval Supply (NAVSUP) Fleet Logistics Center Jacksonville (FLCJ) | Transportation | NTVE Accessories Installation and Removal | A015 | A015AC | 1700000 | 3.3 | NTVE Accessories Installation and Removal | |
| Navy Inn | Facility Investment | E/U/R Work | A016 | A016AA | 1502000 | 3.1 | E/U/R Work - 46 EA | |
| Navy Inn | Facility Investment | Preventive Maintenance Program | A016 | A016AB | 1502000 | 3.2.3 | Auxiliary Generators | |
| Navy Inn | Facility Investment | Preventive Maintenance Program | A016 | A016AC | 1502000 | 3.2.4 | Boiler Systems | |
| Navy Inn | Facility Investment | Preventive Maintenance Program | A016 | A016AD | 1502000 | 3.2.6 | Door and Gate Systems | |
| Navy Inn | Facility Investment | Preventive Maintenance Program | A016 | A016AE | 1502000 | 3.2.7 | Fire Protection Systems | |
| Navy Inn | Facility Investment | Preventive Maintenance Program | A016 | A016AF | 1502000 | 3.2.11 | HVAC and Refrigeration Systems | |
| Navy Inn | Facility Investment | Preventive Maintenance Program | A016 | A016AG | 1502000 | 3.2.17 | Vertical Transportation Equipment (VTE) | |
| Navy Inn | Facility Investment | Inspection, Testing, and Certification Program | A016 | A016AH | 1502000 | 3.3.1 | Backflow Prevention Devices | |
| Navy Inn | Facility Investment | Inspection, Testing, and Certification Program | A016 | A016AJ | 1502000 | 3.3.2 | Boilers and UPVs | |
| Navy Inn | Facility Investment | Inspection, Testing, and Certification Program | A016 | A016AK | 1502000 | 3.3.8 | Vertical Transportation Equipment (VTE) | |
| Navy Inn | Facility Investment | Other Recurring Services Program | A016 | A016AL | 1502000 | 3.4.1 | Boiler Water Testing and Treatment Services | |
| Navy Inn | Facility Investment | Other Recurring Services Program | A016 | A016AM | 1502000 | 3.4.5 | HVAC Seasonal Start-Up and Shutdown | |
| Navy Inn | Facility Investment | Other Recurring Services Program | A016 | A016AN | 1502000 | 3.4.6 | HVAC Water Testing and Treatment Services | |
| Navy Inn | Facility Investment | Other Recurring Services Program | A016 | A016AP | 1502000 | 3.4.7 | Lighting Systems | |
| Navy Inn | Facility Investment | Other Recurring Services Program | A016 | A016AQ | 1502000 | 3.4.8 | Lint Traps | |
| Navy Inn | Facility Investment | Other Recurring Services Program | A016 | A016AR | 1502000 | 3.4.12 | Drinking Fountains & Water Coolers | |
| Navy Lodge | Facility Investment | E/U/R Work | A017 | A017AA | 1502000 | 3.1 | E/U/R Work - 36 EA | |
| Naval Surface Warfare Center (NSWC) Corona | Facility Investment | E/U/R Work | A018 | A018AA | 1502000 | 3.1 | E/U/R Work - 16 EA | |
| Naval Surface Warfare Center (NSWC) Corona | Facility Investment | Preventive Maintenance Program | A018 | A018AB | 1502000 | 3.2.3 | Auxiliary Generators | |
| Naval Surface Warfare Center (NSWC) Corona | Facility Investment | Preventive Maintenance Program | A018 | A018AC | 1502000 | 3.2.11 | HVAC and Refrigeration Systems | |
| Naval Surface Warfare Center (NSWC) Corona | Facility Investment | Inspection, Testing, and Certification Program | A018 | A018AD | 1502000 | 3.3.4 | Grounding Points and Grounding Systems | |
| Naval Surface Warfare Center (NSWC) Corona | Facility Investment | Other Recurring Services Program | A018 | A018AE | 1502000 | 3.4.5 | HVAC Seasonal Start-Up and Shutdown | |
| Naval Surface Warfare Center (NSWC) Corona | Facility Investment | Other Recurring Services Program | A018 | A018AF | 1502000 | 3.4.7 | Lighting Systems |
Total Recurring Work Line Items:
&P Source Selection Information. See FAR 2.101 and 3.104.
File details come from the government source that posted it. Updated .