ASBESTOS
Assumed
This inspection was performed in accordance with the Utah Division of Air Quality (DAQ) requirements as found in the Utah Air Quality Rule R307-801-10. This inspection report is required to be on site during all abatement, renovation, and demolition activities. Samples referenced in this report were analyzed by polarized light microscopy (PLM) utilizing method 600R-93-116 by The Science and Engineering laboratory at
Hill Air Force Base, Utah.
Exterior of facilities and mechanical rooms
Refurbish the HVAC systems.
Replace air conditioning equipment
Affected Area:
September 2015
Scott Combe
309 MMXG
Date Requested:
Requester:
Organization:
Location & Building:
Inspector:
58595
Statement of Work:
DEPARTMENT OF THE AIR FORCE
75 CIVIL ENGINEERING (CEOHA)
HILL AIR FORCE BASE, UTAH
REFURBISH HVAC SYSTEM
HILL AFB BUILDINGS, 2405 AND 2408
Inspection Date:
Work Order:
LIMITED ASBESTOS INSPECTION REPORT, HILL AFB BUILDINGS, 2405 AND 2408
Civil Engineering personnel also reviewed previous asbestos inspection reports of suspect asbestos containing building materials (ACM) that could potentially be encountered in this area. The information gathered from all current and previous inspections is shown below by homogenous area.
MATERIAL TYPE *LOCATIONS FOUNDQUANTITY
100 Linear
Feet
Category I, Potential RACM Non-Friable
14 October 2015
Chase Johnson (Utah Certified Asbestos
Inspector ASB#-5645)
*RACM
*Category I
*Category II
FRIABILITY
(During
Removal)*
Roof Flashing Duct Roof Penetrations and all
Other Flashing Areas.
SUMMARY OF ASBESTOS FOUND
A total of 6 1
GM153806
South Exterior Duct, Building 2405 None Detected
GM153807
South Exterior Duct, Building 2405 None Detected
Duct Insulation, Metal/Black/Yellow
GM153808
North Exterior Duct, Building 2408 None Detected
GM153809
North Exterior Duct, Building 2408 None Detected
GM153810
North Exterior Duct, Building 2408 None Detected
The following table summarizes the sampling data.
Homogenous Building Material, Description, Location, Quantity.
RACM: Regulated Asbestos-Containing Material (RACM)" means friable ACM, Category I non-friable ACM that has become friable, Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation project operations.
Locations found: Locations of building materials as described in this report indicate where they were found, but do not necessarily mean that these are the only locations where these materials may be encountered during the project.
Category II Non-Friable ACM: Any material, excluding Category I non- friable ACM, containing more than
1% asbestos as determined by using the methods specified in 40 CFR Part 763, Subpart E, Appendix E, Section
1, Polarized Light Microscopy (PLM) that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.
suspect materials assesses as part of the inspection.
Sample #
Duct Insulation, Metal/Black/Yellow
GM153805
South Exterior Duct, Building 2405 None Detected
*Per UDAQ definition.
Sample Location
Category I Non-Friable ACM: Asbestos-containing packings, gaskets, resilient floor coverings, or asphalt roofing products containing more than 1% asbestos as determined by using the method specified in 40 CFR
Part 763, Subpart E, Appendix E, Section 1, Polarized Light Microscopy (PLM).
Results
The following is a list of the "Suspect Materials" that were sampled as part of this inspection:
samples reference the
Building: 2405 and 2408
Refurbish HVAC System
WO#: 58595
6 November 2015
1330 Hours
Asbestos/LBP Shop (801)777-8006
This inspection report only encompasses the areas/materials designated within this report. Should the scope of the project be altered in any way or any materials found that are not identified in this report shall require additional assessment. This report cannot be used for any other projects within the building.
POTENTIAL FOR ADDITIONAL MATERIALS:
Any questions or concerns regarding this inspection report or if any new suspect asbestos containing material (ACM) is encountered, stop work and contact the personnel listed below for further assistance.
Cell: (801)430-4785
Supervisor: Nickolas King: DSN: (801)586-7094
Asbetsos/LBP Shop 75 CES(CEOHA)
CONTACT INFORMATION
This report was inspected by:
Chase Johnson (Utah Certified Asbestos Inspector ASB#-5645) of the 75 CES/CEOHA Asbestos/LBP Shop.
Building: 2405 and 2408
Refurbish HVAC System
WO#: 58595
6 November 2015
1330 Hours