Text version
54.0000 (36.00)
5.0000
7.
5.0000
5.
1.0625
5.
7.0000
5.
1.
5.5625
.0
<4.0000>
7.
5.0000
1.0625
9.0000
9.
.47
.5
23.5000
A
A
B B
TYPICAL ALL REBAR TO ANGLE IRON JOINTS TYPICAL
TYPICAL
ALL
TYPICAL ALL
REBAR CROSSINGS
SECTION A-A
0.3750
TYPICAL
4.
0.
C
SECTION B-B
1/4" x 4" x 4"
ANGLE IRON
1/4" PLATE
TYPICAL
DETAIL C
SCALE 1 : 1
NOTE:
BLDGS 980, 975, 970, & 965 SHALL HAVE BURGLAR•
BARS WITH DIMENSIONS OF 54" X 44"
BLDGS 940, 950, & 945 SHALL HAVE BURGLAR•
BARS WITH DIMENSIONS OF 36" X 44"
ALL OPENINGS WITHIN THE FRAME WORK SHALL NOT EXCEED •
4" X 4"
A36 STEEL
BURGLAR BARS FOR BLDGS
940, 945, 950, 965, 970, 975, 980
BURGLAR BAR
WEIGHT:
A1
SHEET 1 OF 1SCALE:1:5
DWG NO.
TITLE:
REVISIONDO NOT SCALE DRAWING
MATERIAL:
DATESIGNATURENAME
DEBUR AND
BREAK SHARP
EDGES
FINISH:UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
TOLERANCES:
LINEAR:
ANGULAR:
Q.A
MFG
APPV'D
CHK'D
DRAWN