Building: 2405 and 2408 Refurbish HVAC
WO#: 58595 6 November 2015 1335 Hours
DATE:
75TH CES/CEOHA
Building
Inspector:
Building
Note:
06-November-2015
ORGANIZATION:
Niton used for this inspection: XRF Analyzer XL3t 300 (Serial #30660)
REQUESTER:
2405 and 2408 58595 Lead Based Paint (LBP) Survey, WORK ORDER:
Scott Combe
309 MMXG
Built in:
Refer to "Readings" tab for all readings.
14-October-2015
Building 2405 and 2408
Niton:
3-The U.S. Department of Housing and Urban Development defines Lead-based paint as any paint, varnish, stain, or other applied coating that has 1mg/cm² as measured by an X-ray Fluorescence (XRF) Analyzer or laboratory analysis or 0.5 percent by weight (5,000 µg/g by dry weight) by laboratory analysis, or more of lead. All other components tested were less than 1 mg/cm².
4-Any effort to disturb lead paint can create lead dust. Please ensure that appropriate abatement, cleanup, and disposal will be accomplished and that the appropriate safety measures are taken IAW 29 CFR 1926.62. If you have any questions please feel free to call Nickolas King at 586-7094.
Chase Johnson (Utah Certified Lead Inspector #PB-2125)
Inspector:
1-Lead based paint was non-detected. Please refer to specific results of this inspection; see attachment 1.
2-Limited lead-based paint identification has been completed for, DEPARTMENT OF THE AIR FORCE
75TH CIVIL ENGINEERING (CEOHA)
HILL AIR FORCE BASE, UTAH
FROM:
SUBJECT:
Inspection Date:
1961 and 1962
SCOPE OF WORK: Refurbish HVAC
XRF Analyzer XL3t 300 (Serial #30660)
Chase Johnson (Utah Certified Lead Inspector #PB-2125)
2405 and 2408 It is possible that lead based paint could be encountered during any renovation project. Additional identification for lead based paint on other building components may be required. The facility manager should ensure that these components are surveyed for lead as well, to meet OSHA Standard 29 CFR 1926.62 construction requirements for lead.
Building: 2405 and 2408 Refurbish HVAC
WO#: 58595 6 November 2015 1335 Hours