Attachment_33_-_Attachment_6_B270_Survey_LBP.pdf
PDF 55 KB Posted
- Attached to
- Multiple Award Construction Contract (MACC) III for Hill Air Force Base, UT Federal contract opportunity
- Solicitation number
- FA8201-15-R-0019
About this file
Attachment 33 - Seed SOW Attachment 6 B270 Survey LBP
View the file
Other files for this federal contract opportunity
Show all 50
Multiple Award Construction Contract (MACC) III for Hill Air Force Base, UT has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
75TH CIVIL ENGINEERING (CEEV)
HILL AIR FORCE BASE, UTAH
19 October 2015
MEMORANDUM FOR: 309 MXSS (Mr. Bart Priest)
FROM: 75 CES/CEOHA
SUBJECT: Lead Based Paint (LBP) Survey, Building 270 (WO #57659). Install three new LO paint booths.
1. On 21 August 2014, Neldon Anderson (Utah LBP Certification #PB-1072) tested the painted components of building 270 that would be impacted by installing three new paint booths. This building was built in 1943. A Niton XL3t 300 Serial#30660 was used to test the painted surfaces of these components. Please refer to specific results of our survey; see attachment 1.
2. The table below summarizes the building components in building 270 that tested positive for LBP. These components should be segregated or abated prior to renovation or demolition, and a composite TCLP taken of the waste before disposal.
(See attached results for further detail).
Component Color Lead Read Condition C-130 Metal Safety Hand Rail Yellow .9 Good
3. The U.S. Department of Housing and Urban Development defines Lead-based paint as any paint, varnish, stain, or other applied coating that has 1mg/cm2 as measured by an X-ray Fluorescence (XRF) Analyzer or laboratory analysis or 0.5 percent by weight (5,000ug/g by dry weight) by laboratory analysis, or more of lead. All other components tested were less than 1 mg/cm2.
4. Any effort to disturb lead paint can create lead dust. Please ensure that appropriate abatement, cleanup, and disposal will be accomplished and that the appropriate safety measures are taken IAW 29 CFR 1926.62. If you have any questions please feel free to call Nickolas King at 586-7094.
//original signed// Neldon Anderson 75th CES/CEOHA Certified LBP Inspector Utah Certification #PB-1072
Attch: Survey Results