SECTION 08 14 16
FLUSH WOOD DOORS
PART 1 – GENERAL
1.01 Related Documents
A.
Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.02 Summary
A.
This Section includes provision of all labor, materials, tools, and equipment necessary to furnish and install standard type solid core wood doors, with flush wood‑veneer faces, including:
1.
Factory‑machining and cut‑outs for hardware, viewlites, and louvers.
2.
Factory‑finishing.
3.
Field‑fitting of wood doors to frames.
4.
Installation of door hardware, glazing, and louvers.
B.
Related Sections:
Section 08 11 13 – Hollow Metal Doors and Frames: Hollow metal frames.
Section 08 71 00 – Door Hardware.
1.03
REFERENCES
A.
Definitions:
Or approved equal = Products similar to those listed immediately above and equivalent in quality, function, durability, and longevity (as determined by the Contracting Officer).
Reference Standards: The publications listed below form a part of this Section to the extent referenced. The publications are referred to within the text by the basic designation only.
General: In case of conflict between any of the referenced specifications or standards – or between this Section and any of the referenced specifications and standards, the one having the more stringent requirements shall govern.
Architectural Woodwork Institute (AWI) Architectural Woodwork Quality Standards Illustrated, Eighth Edition (Version 1.0), 2003 (AWI QSI).
1.04
SUBMITTALS
A.
General: Submit the following per the General Requirements.
Action Submittals:
Product Data and Shop Drawings: For each type of door, indicate:
a.
AWI Type.
b.
The Door Manufacturer's name.
c.
Thickness.
d.
Core constructions.
e.
Size of parts.
f.
Jointing methods.
g.
Face veneers.
h.
The arrangement or pattern.
i.
Hardware locations.
j.
Location(s) and size(s) of cut‑outs for glass and louvers.
k.
Factory‑finishing specifications.
l.
Other pertinent information.
Submit Samples for each face material and finish.
1.05 Delivery, Storage, and Handling
A.
Package doors individually in heavy, cardboard cartons prior to shipment.
B.
Mark both doors and carton with opening number and net size of door.
C.
Relative humidity in building and storage conditions shall be suitable to receive doors before doors are delivered to the Site.
D.
Store doors flat prior to hanging.
E.
Keep doors in cartons until ready to hang.
F.
Reposition cartons over doors after hanging to provide protection until area in which doors are hung is free of construction traffic.
PART 2 – PRODUCTS
2.01
MANUFACTURERS
Flush Wood Doors:
Algoma Hardwoods, Incorporated, Algoma WI (Website: www.algomahardwoods.com, Voice: 800.678.8910).
Buell Door Company, Dallas TX (Website: www.buelldoor.com, Voice: 800.556.0155).
Architectural Door Division of Eggers Industries, Two Rivers WI (Website: www.eggersindustries.com, Voice: 920.793.1351).
Graham Manufacturing Corporation, Essex Industries, Incorporated, ASSA ABLOY AB, Mason City IA (Website: www.grahamdoors.com, Voice: 641.423.2444).
5.
Marshfield Door Systems Incorporated, Marshfield WI (Website: www.marshfielddoors.com, Voice: 800.869.3667).
6.
Mohawk Flush Doors, Incorporated, Masonite International Corporation, Northumberland PA (Website: www.mohawkdoors.com, Voice: 570.473.3557).
7.
Oshkosh Architectural Door Company, Oshkosh WI (Website: www.oshkoshdoor.com, Voice: 920.233.6161).
8.
VT Industries Incorporated, Holstein IA (Website: www.vtindustries.com, Voice: 800.827.1615).
9.
Or approved equal.
2.02 Materials
Formaldehyde Content:
Do not use adhesives containing urea‑formaldehyde.
Do not use particleboard made with a binder containing urea‑formaldehyde resin.
Maximum Allowable Formaldehyde Emission Rate of Fabricated Door: 0.30 PPM at the loading ratio defined in ASTM E‑1333.
2.03 Manufactured Units
Flush Interior Doors:
1 3/4‑inches thick
Construction: Five or seven plies with stiles and rails bonded to core of glued block Abrasive‑plane entire unit before veneering.
Face Veneers:
Grade: Premium with Grade AA faces.
Species and Cut: Birch plain‑sliced.
Assembly of Veneer Leaves on Door Faces: Balance match.
B.
Glass and Louver Stops: Same species as face veneers.
C.
Glazing:
Clear, fully tempered, with a minimum thickness of 1/4 inch.
2.04
FABRICATION
Fabricate standard type solid core doors per the requirements of Section 1300 of the AWI QSI:
Type SLC5 (Glued Block Core Five Ply Bonded).
Type SLC7 (Glued Block Core Seven Ply Bonded).
B.
Provide doors with minimum 3/4‑inch thick edge strips, of wood species to match face veneers.
C.
Fabricate doors in sizes indicated for field‑fitting. Pre‑fit doors to provide the following clearances:
At Sides and Top: Not more than 1/8 inch.
At Bottom: Not more than 1/4 inch.
Exception Above Top of Carpet (where thresholds are not provided): Not more than 1/2 inch.
D.
Openings: Make cut‑outs and provide stops for openings through doors to comply with applicable requirements of referenced standards for kind(s) of door(s) required.
Viewlites: Trim openings with moldings of material and profile indicated.
Louvers: Factory‑install louvers in prepared openings.
E.
Fabricate doors with bevel or radius on all vertical edges.
Beveled Strike Edge of Single‑Acting Doors: 1/8 inch in 2 inches.
F.
Prepare doors to receive hardware.
Factory‑machine doors for hardware that is not surface‑applied.
2.05 Finishes
A.
General: Finish doors at factory that are indicated to receive transparent finish.
B.
Grade of Finish: Premium.
C.
AWI System: Catalyzed polyurethane (TR‑6).
D.
Staining: As selected from the Finish Manufacturer's full range.
E.
Effect: Semi‑filled finish.
F.
Sheen: Semi‑gloss.
PART 3 – EXECUTION
3.01
INSTALLATION
Install wood doors:
Per the Wood Door Manufacturer’s written instructions.
Per the referenced quality standard.
As indicated on the Drawings.
Field‑Fitting:
Align and fit doors:
Plumb and square in frames.
With uniform clearances and bevels.
With the following site tolerances:
1) Maximum Diagonal Distortion: 1/16 inch.
2) Clearance at Sides and Top: 1/8 inch.
3) Clearance at Bottom: 1/4‑inch.
Do not trim rails in excess of limits set by the Wood Door Manufacturer.
Machine doors for hardware.
Seal cut surfaces after fitting and machining.
Factory‑Finished Doors: If field‑fitting or ‑machining was required, restore finish before final hanging of doors in place.
C.
Install hardware.
D.
Coordinate installation of glass and glazing.
E.
Install door louvers.
3.02 Cleaning
Upon completion of the Work, remove surplus materials, debris, tools, and equipment from the Site.
END OF SECTIOn 08 14 16