6 of 056 - S101 - Foundation Plan Rev 01 2021-07-13 (Q7 and Q10).pdf
PDF 631 KB Posted
- Attached to
- Repair Maintenance Hanger, Bldg 700
- Solicitation number
- FA441821R0015
About this file
This foundation plan details requirements for repair work on a maintenance hanger at Joint Base Charleston, South Carolina. The project involves removing and replacing asphalt paving, installing new steel columns and concrete foundations, adding ladder access, bracing, masonry walls, windows and ductwork. Foundation elements include spread footings, grade beams and tie beams with reinforcing schedules. The related solicitation seeks bids for repair and maintenance of Building 700 under Air Force contract FA441821R0015 to ensure aircraft maintenance capabilities. The scope involves structural, architectural and mechanical, electrical and plumbing work per the plans. The award date is unspecified but the response deadline is prior to the listed issue date of the foundation plan.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TYPICAL TOP OF FTG = -1'-4"
THE G.C. SHALL COOORD WITH TYPICAL DETAILS FOR ANY AND ALL
ADDITIONAL FRAMING REQUIREMENTS NOT SHOWN HEREIN.
= EXISTING FOUNDATIONS / BUILDING
• SF=STEP FOOTING, SEE TYPICAL DETAIL X/S-XXX
• CENTER ALL SPREAD FOOTINGS BENEATH
COLUMNS/PIERS/PILASTERS
• ALL STRIP FOOTING REINFORCING SHALL BE CONTINUOUS THROUGH
SPREAD FOOTINGS
• PROVIDE CORNER BARS AT ALL STRIP FOOTING CHANGES IN
DIRECTION
EXTEND STRIP FOOTINGS A MINIMUM OF 8" PAST END OF WALL AT
FOOTING TERMINATIONS
TYPICAL EXTERIOR SLAB ON GRADE CONSTRUCTION IS 4" SLAB W/ ONE
LAYER OF 6x6~W2.9xW2.9 WWR ON COMPACTED SUBGRADE. SEE SPECS
FOR FINISH REQUIREMENTS. SEE ARCH'LS AND CIVIL FOR ELEVARTIONS
AND SLOPES.
FOUNDATION PLAN NOTES:
0.20.1
A.1
A.2
H
SS
5X 5X
3/
H
SS
5X 5X
3/
H
SS
5X5X3/8
H
SS
5X5X3/8
F55
F55
F44
EXIST BLDG
102102
105105
105105
EXISTING 1990's
STEEL FRAME &
REINFORCED CMU
BLDG BLDG
0.3
F44
102102
102102
107 107
T B
-1 .5
TB-1.5
TB-1.5
T B
-1 .5
/8
A.3
19'-6 1/4" +/- 4'-3"
/4
/8
/8
/8
EXIST F20 H
SS6X
6X 3/
H
SS6X
6X 3/
119119
EQ EQ EQ
E Q
E Q
S241
S241
28'-9 1/4" +/-
CJ
CJ
CJ
S201
S201
S201
S201
117117
10'-10"
4"
19'-6 1/4" 4'-3"
117117
117117
117117
117117 117117
F125
1'-3"
102114
S201
4" Slab on Grade
S201
121121
121121
121121
121121
118 118
118 118
10B
S201
1 1
102102
7B
S201
7A
S201
7A
S201
GB/TB SCHEDULE NOTES:
1. SEE TYPICAL DETAILS ON SXXX SERIES OF DRAWINGS FOR TREATMENT OF REINFORCING AT INTERSECTIONS WITH PILE
CAPS, GB'S OR TB'S.
2. SEE X/SXXX FOR SPLICING REQUIREMENTS.
3. ALL STIRRUPS SHALL BE CLOSED WITH SEISMIC BENDS.
4. MAINTAIN 4" CLEAR COVER AROUND ALL REINFORCING UNO.
5. ALL BARS SHALL BE SUPPORTED ON CHAIRS (PLASTIC OR HDG) WITH FLAT BASED TO PREVENT SINKING INTO SUBGRADE
6. LOCATE FIRST STIRRUP 4" OR LESS FROM FACE OF PILE CAP OR SUPPORTING GRADE/TIE BEAM UNO
7. ALL CONTINUOUS GRADE BEAMS (PRESENT BOTH SIDES OF PILE CAP, GB OR TB) SHALL HAVE TOP AND BOTTOM BARS
CONTINUOUS THROUGH INTERRUPTING PILE CAP, GB OR TB, SEE X/SXXX.
C E
R T
IF
ICATE OF AUTHOR
I Z A
T I O
NENGINEERING
ADC
NO. 00253
INC.
S O
U
T H
C A R O L
I N
A
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D
AT
E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T O F
TH
E
AI
R
FO
RC
E
AI
R M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K
BY
D
R
AW
N B
Y:
D
SG
N
B Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G
S
TR
E E
T, S
U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
07/27/2017
R E V
IS
IO
N
C J G
C J G
S101
FO
U N
DA
TI
O N P
LA
N
A C P
A C P
C J G
JB
C
AB
B R
EP
AI
R A
IR
C R
AF
T
M
AI
N
TE
N
AN
C E H
AN
GE
R
ADC #17005.0
KEYED NOTES (THIS SHEET ONLY)
102 REMOVE & REPLACE EXISTING ASPHALT PAVING AS NEEDED TO INSTALL NEW COLUMNS AND FOUNDATIONS.
104 NEW LADDER, BOLT TO WALL, LADDER SHALL BE PER STEEL SUPPLIER / FABRICATOR, LADDER SHALL BEET ALL CURRENT OSHA AND IBC CODE REQUIREMENTS.
105 T/EXISTING SLAB = 0'-0"
106 PROVIDE PROTECTIVE/ RESTRICTIVE ACCESS TO LADDER (LOCKABLE LADDER COVER)
107 HSS 4x4x1/4" DIAGONAL BRACING BETWEEN COLUMNS. PROVIDE 1/2" GUSSET PL's (HDG).
109 HSS 6X6X3/8 HDR & SILL.
110 NEW 3000 PSI CONCRETE FTG 12"X12"X5'-0". SEE TYP DETAIL.
111 NEW TYPE B CMU INTEL OVER OPENING.
112 REINFORCE 2 ADJACENT CELL EACH SIDE OF OPENING.
113 NEW 8"CMU BOND BEAM SILL W/ 2-#4'S CONT., BELOW OPENING.
114 PROVIDE NEW 4" 3000-PSI (NW) CONCRETE SLAB WITH 6x6~W2.9xW2.9 WWF. PROVIDE CONTROL JOINTS @ 10'-0" O.C. EACH DIRECTION
115 SEE ARCH'LS FOR WINDOW SIZE AND LOCATION.
116 SEE MEP AND ARCH'LS DRWG'S FOR DUCT SIZE AND LOCATION.
117 THE G.C. SHALL BE RESPONSIBLE FOR FIELD LOCATING ALL UNDERGROUND UTILITIES AND INTERFERENCES PRIOR TO DIGGING FOUNDATIONS.
118 DEMO EXISTING BOLLARDS. COORD. W/ ARCH'LS
119 EXISTING UNDERGROUND OIL SEPERATOR/CONTAINMENT THE G.C. SHALL TAKE SPECIAL CARE TO PROTECT. N. HEAVY EQUIPMENT SHALL BEAR ON THIS STRUCTURE. THE G.C.
SHALL FIELD LOCATE AND CLEARLY MARK G.C. TO CONFIRM TOP OF UNIT = -1'-0"
120 FOOTING MAY BE SLIGHTLY OFF CENTER DUE TO EXISTING OIL SEPERATOR. COLUMN TO REMAIN WHERE LOCATED
121 NEW 3000-PSI CONCRETE SLAB G.C. TO COORD. EXTENTS. PROVIDE POSITIVE DRAINAGE AWAY FROM THE BUILDING. TIE INTO ADJACENT SURFACES AND ALLOW POSITIVE WATER
FLOW AWAY FROM THE BUILDING
1/2" = 1'-0"1 FOUNDATION PLAN -AREA-B
GRADE BEAM/TIE BEAM SCHEDULE
TYPE WIDTH THICKNESS
TOP
REINFORCING
BOTTOM
REINFORCING STIRRUPS
TB-1.5 1'-6" 1'-0" (3)-#5'S (3)-#5'S #3'S @ 5" O.C.
SPREAD FOOTING SCHEDULE
FOOTING
TYPE LENGTH WIDTH THICKNESS BOTTOM REINFORCING TOP REINFORCING
F32 2'-0" 3'-0" 1'-0" (3)-#5's LINGITUDINAL, (4)-#5'S
TRANSVERSE
N/A
F44 4'-0" 4'-0" 1'-0" (5)-#5'S EW N/A
F55 5'-0" 5'-0" 1'-6" (6)-#5'S EW N/A
F125 5'-0" 1'-0" 1'-0" (3)-#5'S EW N/A
CONTINUOUS FOOTING SCHEDULE
FOOTING TYPE WIDTH THICKNESS
LONGITUDINAL
REINFORCING
TRANSVERSE
REINFORCING
EXIST F15 1'-6" 1'-0" EXIST (2)-#5'S N/A
EXIST F20 2'-0" 1'-0" EXIST. (3)-#5'S N/A
No. 28196