Attachment 5 Repair Aircraft Maint Hangar Fire Systems B700 Drawing Set.pdf
PDF 2 MB Posted
- Attached to
- Repair Maintenance Hanger, Bldg 700 Federal contract opportunity
- Solicitation number
- FA441821R0015
About this file
This package includes construction drawings and specifications for repair work to an aircraft maintenance hangar building and its fire systems at Joint Base Charleston, South Carolina. The scope of work includes replacing the fire alarm and mass notification system, installing new optical flame detectors, relocating manual foam release stations, and modifying the high-expansion foam system piping. Mechanical work consists of replacing an existing mini-split heat pump serving the foam room. The solicitation is for repair services in accordance with provided design documents and specifications issued by the Department of the Air Force under solicitation number FA441821R0015.
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G
E W
B
A IR AS
I N 62 8T H
I
R A
D
M A
N
COM
MO
IT Y
B I L
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D A
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
G000
C O
VE
R
S H
EE
T
D es ig ne r P
JO
S
M
1/
/2
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
1051184 TWCF
1051184 TWCF
REPAIR AIRCRAFT MAINTENANCE HANGAR FIRE
SYSTEMS BUILDING 700
JOINT BASE CHARLESTON AIR BASE WING
CHARLESTON, SOUTH CAROLINA
100% SUBMITTAL
ARCHITECT
GLICK/BOEHM & ASSOCIATES
493 KING STREET, SUITE 100
CHARLESTONG, SC
843.577.6377
JANUARY 29, 2021
MECHANICAL/ELECTRICAL ENGINEER
DWG, INC.
1099 ANNA KNAPP BLVD, SUITE 202
MOUNT PLEASANT, SOUTH CAROLINA 29464
843-849-1141
(Legacy Project No. DKFX 11-1171)
SHEET TITLE
G000 COVER SHEET
E200 ELECTRICAL NOTES & FOAM ROOM POWER PLAN
ED201 FIRST FLOOR SYSTEMS DEMO PLAN
ED202 SYSTEMS ENLARGED DEMO PLAN
E201 FIRST FLOOR SYSTEMS PLAN
E202 SYSTEMS ENLARGED PLAN
FP100 FIRE PROTECTION PLAN
M100 MECHANICAL FOAM ROOM PLAN
PROJECT DRAWING LIST
SYMBOL LEGEND
DESCRIPTIONSYMBOL
SD DUCT MOUNTED SMOKE DETECTOR
CLEAR FIRE STROBE AND SYSTEM SPEAKER
(CEILING MOUNTED)
AMBER MASS NOTIFICATION STROBE (CEILING
MOUNTED)
F
M
CLEAR FIRE STROBE
(WALL MOUNTED)
AMBER MASS NOTIFICATION STROBE (WALL
MOUNTED)M
REMOTE FIRE ANNUNCIATOR PANEL
FIRE ALARM PULL STATION
RFAP
F
F
LOC LOCAL OPERATING CONSOLE
TS
FS
TAMPER SWITCH
FLOW SWITCH
NOTIFICATION SPEAKER CLUSTER (4
LOUDSPEAKERS CEILING MOUNTED)
CEILING MOUTNED SMOKE DETECTORSD
OPTICAL FLAME DETECTOROFD
FACP
MNS
FIRE ALARM CONTROL PANEL
MASS NOTIFICAITON SYSTEM PANEL
1. AREAS OF WORK EXIST FOR THIS PROJECT WHICH WERE NOT ACCESSIBLE OR HAD LIMITED ACCESS DURING DESIGN. AS SUCH, CONTRACTOR SHALL VERIFY ALL UTILITIES IN AREA OF WORK BEFORE DEMOLITION OF ANY SERVICE. ANY ELECTRICAL COMPONENTS NOT SHOWN SHALL BE IDENTIFIED AND THE ARCHITECT AND ENGINEER SHALL BE NOTIFIED AS SOON AS POSSIBLE. NO ELECTRICAL REWORK SHALL BE COMMENCED WITHOUT COORDINATION OF BOTH ARCHITECT AND ENGINEER. WHERE INFORMATION SHOWN ON THESE DRAWINGS CONFLICTS WITH VERIFIED FIELD CONDITIONS, IT SHALL BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER.
2. IN AREAS WHERE THE EXISTING CEILINGS ARE NOT SLATED TO BE REPLACED, THE CONTRACTOR SHALL WORK THROUGH THE EXISTING CEILINGS (SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR AREA OF WORK).
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING A FIRESTOP SYSTEM IN ALL PENETRATIONS OF FIRE-RATED FLOORS AND WALLS CREATED BY THE REMOVAL OF EXISTING ELECTRICAL CONDUIT OR CABLES, AS WELL AS THOSE
CREATED BY NEWLY INSTALLED CONDUITS AND SLEEVES.
4. WHERE INSTALLATION REQUIRES CUTTING OR DRILLING OF THE EXISTING FLOOR SLAB, THE CONTRACTOR SHALL X-RAY THE EXISTING SLAB PRIOR TO WORK TO ENSURE THAT NO EXISTING UTILITIES OR STRUCTURAL ELEMENTS IN THE SLAB WILL BE COMPROMISED BY THE WORK. NOTIFY THE A/E OF ANY CONFLICTS THAT WILL REQUIRE RELOCATING THE PROPOSED SLAB WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGED UTILITIES OR STRUCTURAL
ELEMENTS CAUSED BY THE SLAB DEMOLITION.
GENERAL EXISTING CONDITION NOTES
GENERAL SIGNAL NOTES
1. PROVIDE CONDUIT FOR HVAC CONTROL CIRCUITS AS REQUIRED TO INTERCONNECT HVAC UNIT TO CONTROL CIRCUITS. ELECTRICAL
CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR AND CONTROLS PROVIDER TO DETERMINE SCOPE OF CONDUITS REQUIRED FOR HVAC CONTROLS. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED CONDUIT. COORDINATE POINTS OF CONNECTION WITH DIVISION 23. PROVIDE PULL CORD IN ALL EMPTY CONDUITS. SEE MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL HVAC EQUIPMENT (AHU, HP, CU, RTU, DUCT SMOKE DETECTORS, VAV, FCU, THERMOSTATS, ETC).
2. PROVIDE ALL DUCT SMOKE DETECTORS AND ACCESSORIES NECESSARY FOR INTERLOCKING WITH MECHANICAL EQUIPMENT (AHU'S, SMOKE DAMPERS, ETC). COORDINATE WITH MECHANICAL PLANS FOR LOCATIONS AND REQUIREMENTS.
3. THESE DOCUMENTS MAY NOT INCLUDE ENTIRE ELECTRICAL INFRASTRUCTURE REQUIRED TO SUPPORT THE BUILDING AUTOMATION SYSTEM. COORDINATE WITH BAS PROVIDER ON ALL NECESSARY INFRASTRUCTURE FOR A COMPLETE AND WORKING SYSTEM.
1. BRANCH CIRCUIT WIRING FOR 20A/120V CIRCUITS LESS THAN 100' FROM PANEL TO FARTHEST DEVICE SHALL BE 2-#12s, #12 GND IN 3/4" C. AND 2-#10s, #10 GND IN 3/4" C. FOR CIRCUITS GREATER THAN 100' UNLESS NOTED OTHERWISE. WHERE CONDUCTOR AND RACEWAY SIZE ARE SHOWN AT HOMERUN, SUCH SIZE SHALL BE USED FOR THE ENTIRE CIRCUIT. EXCEPTION: FINAL CONNECTION TO
DEVICES IN OUTLET BOXES IS NOT REQUIRED TO BE LARGER THAN #12.
2. PRIOR TO ROUGH-IN, COORDINATE THE LOCATION AND MOUNTING HEIGHT OF ALL WALL MOUNTED DEVICES WITH THE ARCHITECTURAL INTERIOR ELEVATIONS AND MILLWORK SHOP DRAWINGS. IN THE EVENT OF A CONFLICT, NOTIFY THE ARCHITECT.
MINOR ADJUSTMENTS IN DEVICE LOCATION, SUCH AS 5'-0" IN ANY DIRECTION, SHALL BE DONE AT NO ADDITIONAL COST TO THE OWNER. UNDERCABINET LIGHT FIXTURES, RECEPTACLES AND OTHER DEVICES TO BE MOUNTED INSIDE CABINETS SHALL BE REVIEWED WITH THE ARCHITECT PRIOR TO ROUGH IN TO CONFIRM THE EXACT LOCATION OF FIXTURES AND DEVICES.
3. RACEWAYS SHALL BE INSTALLED CONCEALED IN NEW WALL CONSTRUCTION, ABOVE CEILINGS, BELOW FLOOR AND IN OTHER CAVITIES TO THE GREATEST EXTENT POSSIBLE. EXPOSED RACEWAYS MAY BE USED IN UNFINISHED SPACES, WHERE EXPLICITLY NOTED ON PLANS AND WHERE APPROVED BY THE ARCHITECT AND ENGINEER. LAY OUT EXPOSED RACEWAYS TO MINIMIZE THE
NUMBER OF VERTICAL RUNS.
4. BRANCH CIRCUIT ROUTING SHALL COMPLY WITH DETAILS ON DRAWINGS AND SHALL BE COORDINATED WITH THE WORK OF OTHER TRADES BEFORE AND DURING CONSTRUCTION. BRANCH CIRCUITS SHALL BE ROUTED OVERHEAD UNLESS PRIOR APPROVAL HAS
BEEN GRANTED BY THE ARCHITECT AND ENGINEER.
5. A FIRESTOP SYSTEM SHALL BE USED TO SEAL ALL PENETRATIONS OF ELECTRICAL CONDUITS AND CABLES THROUGH FIRE-RATED PARTITIONS. THE FIRESTOP SYSTEM SHALL CONSIST OF A FIRE-RATED CAULK TYPE SUBSTANCE AND HIGH TEMPERATURE FIBER INSULATION BY STI OR APPROVED EQUAL. ONLY METAL CONDUIT SHALL BE USED TO PENETRATE FIRE-RATED PARTITIONS. SEE
ARCHITECTURAL DRAWINGS FOR ALL LOCATIONS OF FIRE-RATED WALLS.
6. THE USE OF MC CABLE IS NOT ALLOWED, UNLESS NOTED OTHERWISE.
7. PROVIDE A LISTED EXPANSION/DEFLECTION FITTING FOR ALL CONDUIT CROSSING EXPANSION JOINTS PER NEC 300.4.H. SEE
ARCHITECTURAL DRAWINGS FOR LOCATIONS OF EXPANSION JOINTS.
8. WHEREVER THE WORD "PROVIDE" IS USED ON THE ELECTRICAL DRAWINGS, IT SHALL BE INFERRED TO MEAN "FURNISH AND INSTALL", UNLESS NOTED OTHERWISE.
9. THE ARRANGEMENT, GROUPING, AND ROUTING OF BRANCH CIRCUITS SHALL BE PROVIDED AT THE CONTRACTOR'S DISCRETION IN
ACCORDANCE WITH GENERALLY ACCEPTED PRACTICE FOR ELECTRICAL WORK, THE NATIONAL ELECTRICAL CODE REQUIREMENTS, LOCAL ORDINANCES, AND THE FOLLOWING: 1 - A COMMON NEUTRAL MAY NOT BE INSTALLED IN A HOMERUN FOR 2 OR 3 BRANCH CIRCUITS. 2 - MULTIPLE SINGLE-POLE BRANCH CIRCUITS (UP TO 3 HOTS, 3 NEUTRALS AND 1 GROUND) RATED FOR 30A OR LESS MAY BE PULLED INTO A SINGLE RACEWAY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SIZING THE RACEWAYS AND DE-RATING CONDUCTORS PER NEC 310.15. 3 - A GROUND CONDUCTOR SHALL BE PROVIDED IN ALL RACEWAYS UNLESS NOTED OTHERWISE.
GENERAL ELECTRICAL NOTES
1. ALL ELECTRICAL EQUIPMENT TO BE REMOVED SHALL REMAIN THE PROPERTY OF THE OWNER. THE CONTRACTOR SHALL NOT DISPOSE OF ANY MATERIALS UNTIL RELEASED BY THE OWNER'S PROJECT MANAGER. MATERIALS THAT THE OWNER'S PROJECT MANAGER CHOOSES TO RETAIN SHALL BE DELIVERED BY THE CONTRACTOR TO A LOCATION DESIGNATED BY THE PROJECT
MANAGER. ALL OTHER MATERIALS SHALL BE PROPERLY DISPOSED OF BY THE CONTRACTOR.
GENERAL DEMOLITION NOTES
G
HP-1
AH-1
FIRE ALARM SINGLE-LINE NOTES
MONACO ENTERPRISES MAAP-X COMBINATION FIRE ALARM/MASS NOTIFICATION PANEL
PROVIDE CABLING AND INPUT MODLES AS REQUIRED FOR ALARM, SUPERVISORY, AND TROUBLE SIGNALS
FOR INTERCONNECTION BETWEEN PANELS.
PROVIDE ONE 4-PAIR TELEPHONE CABLES IN 1/2" EMT TO
COMMUNICATIONS BOARD.
PROVIDE SURGE PROTECTIVE DEVICES FOR ALL INCOMING POWER
CONNECTIONS TO FIRE ALARM CONTROL PANELS, POWER SUPPLIES,
AND BATTERY SYSTEMS.
SPD
120-V
PUSH-TO-TALK
MICROPHONE
ADDRESSABLE INITIATING DEVICES
FIRE ALARM NOTIFICATION CLEAR STROBES/SPEAKERS
FIRE ALARM SYSTEM GENERAL NOTES:
1. SEE FLOOR PLANS FOR INTENDED COVERAGE OF FIRE ALARM
SYSTEM AND MASS NOTIFICATION SYSTEM.
2. THE FOLLOWING SHALL OCCUR UPON ACTIVATION OF ANY INITIATING
DEVICE:
A) SOUND ALL AUDIBLE DEVICES (SPEAKERS, BELLS, ETC.)
AND FLASH ALL VISUAL DEVICES (LIGHTS OR STROBES)
THROUGHOUT THE ENTIRE FACILITY.
B) ALERT CENTRAL STATION ALARM REPORTING SERVICE VIA
RADIO TRANSMITTER.
C) CLOSE ALL SMOKE DOORS THROUGHOUT THE FACILITY.
D) STOP OR START AHU'S OR FANS.
E) INDICATE BY ZONE WITH AUDIO/VISUAL SIGNAL AT FACP AND
ALL REMOTE ANNUNCIATORS.
INITIATING DEVICES SHALL BE SMOKE DETECTORS, DUCT-MOUNTED
SMOKE DETECTORS, MANUAL PULL STATIONS AND SPRINKLER
FLOW SWITCHES.
4. UPON ACTIVATION OF ANY VALVE SUPERVISORY (TAMPER) SWITCH, A
DISTINCT SIGNAL ACCEPTABLE TO THE AUTHORITY HAVING
JURISDICTION SHALL BE SENT TO THE FACP . VISUAL PORTION OF
SIGNAL SHALL BE CONTINUOUS. TONE DURATION SHALL BE 3
SECONDS.
5. SYSTEM TROUBLE (OPEN WIRING, SHORTED WIRING, OR GROUND
FAULTS) SHALL BE ANNUNCIATED BOTH AUDIBLY AND VISUALLY AT
THE FACP AND AT ALL ANNUNCIATORS.
6. ALL SYSTEM WIRING SHALL BE CLASS B, NO T-TAPPING IS PERMITTED.
7. PROVIDE BATTERY AND VOLTAGE DROP CALCULATIONS THAT
INCLUDE ALL EXISTING AND NEW DEVICES AND APPLIANCES
INSTALLED IN SYSTEM AND SUBMIT TO CONTRACTING OFFICER.
8. FIRE ALARM SYSTEM CONTROL EQUIPMENT, ALARM INITIATING
DEVICES, POWER SOURCES, MUNICIPAL OR REMOTE STATION
SIGNALING APPARATUS, AND REMOTE ANNUNCIATION/CONTROL
PANELS SHALL BE UNDERWRITER'S LABORATORIES LISTED FOR THE
INSTALLED APPLICATION.
FOAM
SYSTEM
RELEASING
CONTROL
PANEL
MANUAL FOAM RELEASING STATIONS
BLUE BEACONS
3.
TAMPER SWITCHES, PRESSURE SWITCHES, FLOW SWITCHES
SPD
OPTICAL FLAME DETECTORS
MASS NOTIFICATION AMBER STROBES
COMBINATION
FIRE ALARM/
MASS
NOTIFICATION
PANEL
SPD
ANTENNAE
REMOTE FIRE
ANNUNCIATOR
PANEL (RFAP)
LOCAL OPERATING
CONSOLE (LOC), TYP
5 BATTERY/NAC/AMPLIFIER CABINETS AS REQUIRED.
Scale: 1 / 8 " = 1 ' - 0 "
32 '16 '8 '4 '0
SCALEGRAPHIC
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D A
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
E200
EL
EC
TR
IC
AL
N O
TE
S
FO
AM
R O O M
P O W
ER
P
LA
N
B M
P B
M P
A C
N
2/
/2
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
1051184 TWCF
ELECTRICAL ABBREVIATIONS
ABBR DESCRIPTION
(E) EXISTING
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
EF EXHAUST FAN
EXT. EXTERIOR
FACP FIRE ALARM CONTROL PANEL
FDS FUSED DISCONNECT SWITCH
FSD FIRE/SMOKE DAMPER
HP HEAT PUMP
J-BOX JUNCTION BOX
KW KILOWATTS
MNS MASS NOTIFICATION SYSTEM
NEC NATIONAL ELECTRICAL CODE
NFDS NON-FUSED DISCONNECT SWITCH
TYP TYPICAL
W/ WITH
WP WEATHERPROOF
ELECTRICAL CODES & STANDARDS
CODE DESCRIPTION
ASHRAE 90.1 (2013) AMERICAN SOCIETY OF HEATING, REFRIGERATING AND
AIR-CONDITIONING ENGINEERS ENERGY STANDARD FOR BUILDINGS
IBC (2015) INTERNATIONAL BUILDING CODE
IFC (2015) INTERNATIONAL FIRE CODE
NFPA 70 (2014) NATIONAL ELECTRICAL CODE
NFPA 72 (2016) NATIONAL FIRE ALARM AND SIGNALING CODE
UFC 3-501-01 ELECTRICAL ENGINEERING
UFC 3-520-01 INTERIOR ELECTRICAL SYSTEMS
UFC 3-530-01 DESIGN; INTERIOR AND EXTERIOR LIGHTING AND CONTROLS
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES
UFC 4-021-01 MASS NOTIFICATION SYSTEMS
UFC 4-211-01 AIRCRAFT MAINTENANCE HANGERS
SCALE: 1/8" = 1'-0"E200
2 FIRST FLOOR POWER PLAN- FOAM ROOM
EQUIPMENT CONNECTION SCHEDULE
EQUIPMENT
DESCRIPTION
ELECTRICAL
BRANCH CIRCUIT
WIRING
DISCONNECT /
STARTER NOTESVOLTS
# OF
POLES
LOAD
(VA)
DUCTLESS MINI-SPLIT
AH-1 208 V 2 655 (2) #12, 1#12G, 3/4"C MOTOR-RATED SWITCH 1
SPLIT SYSTEM HEAT PUMP
HP-1 208 V 2 3328 (2) #10, #10G IN 3/4"C NFDS 30/2/3R
EQUIPMENT CONNECTION SCHEDULE NOTES:
1. INDOOR UNIT IS POWERED FROM OUTDOOR UNIT.
2. SEAL ALL CONDUIT PENETRATIONS THROUGH WALL FOR 1-HOUR RATING
SCALE: NOT TO SCALEE200
1 PARTIAL FIRE RISER DIAGRAM
KEYNOTES:
UNIT IS REPLACED IN EXISTING LOCATION. POWER UNIT FROM
EXISTING BREAKER SERVING DEMOLISHED UNIT. EXTEND
EXISTING WIRE AND PROVIDE NEW CONDUIT FOR FINAL
CONNECTION.
DN
DN
DN
UP
R E
F
REF.
F F
F
FF
F F
F
F
F F
F F
F
A
B
C
D
E
F
G
H
10.5 0.90.80.6 0.7
0.1 0.20.3
FOAM ROOM
HANGAR
LPK-2 (E)
LPK-1 (E)
A-2 (E)
ED202
ED202
ED202
ED202
ED202
ED202
Scale: 1 / 1 6 " = 1 ' - 0 "
16 ' 64 '32 '8 '0
SCALEGRAPHIC
N
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D A
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
DEMOLITION KEY NOTES
GENERAL NOTES
ED201
FI
R S T
FL
O O R
S
YS
TE
M S
D
EM
O
P
LA
N
B M
P B
M P
A C
N
1/
/2
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
1051184 TWCF
SCALE: 1/16" = 1'-0"ED201
1 FIRST FLOOR SYSTEMS PLAN
1 EXISTING BLUE BEACONS TO REMAIN
DEMOLISH EXISTING FOAM SYSTEM START / STOP STATIONS.
NEW STATIONS SHALL BE IN APPROXIMATELY THE SAME
LOCATION.
DEMOLISH EXISTING FOAM SYSTEM START / STOP STATIONS.
NEW STATIONS SHALL BE LOCATED ON THE OTHER SIDE OF
THE DOOR IN ACCORDANCE WITH UFC 4-211-01 SECTION
3-6.19.8.1.
1. COORDINATE THE OUTAGE ASSOCIATED WITH THE
DEMOLITION OF THE FIRE ALARM SYSTEM WITH THE JOINT
BASE CHARLESTON PROJECT MANAGER AND BUILDING
OWNER.
1/29/2021
F
F
F
FF
F F
F
F
R E
F
REF.
F
F
F
F
F
F F
SD
F
F
F
F
B
C
D
0.1 0.2 0.3
TOOL ROOM
FLIGHT
LEADERSHIP
SECTION
CHIEFS
STORAGE
WOMENS
RESTROOM
LP (E)
D
COORDINATORS
SHACK
CS-1 (E)
CS (E)
E
F
10.5 0.90.80.6 0.7
BREAK
ROOM
RESERVES
OFFICE
MENS
RESTROOM
BOILER
ROOM
SWBD. (E)
MCC (E)
D
CONFERENCE
OFFICE
F
SHEET
METAL
SHOP
CONFERENCE
/ BREAK
JETS ADMIN.
G
FOAM ROOM
Scale: 1 / 8 " = 1 ' - 0 "
32 '16 '8 '4 '0
SCALEGRAPHIC
N
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D A
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
DEMOLITION KEY NOTES
GENERAL NOTES
ED202
S
YS
TE
M S
EN
LA
R G
ED
D
EM
O
P
LA
N S
B M
P B
M P
A C
N
2/
/2
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
1051184 TWCF
4SCALE: 1/8" = 1'-0"ED202
4 FIRST FLOOR SYSTEMS DEMO PLAN -OFFICE BUILDING
SCALE: 1/8" = 1'-0"ED202
1 FIRST FLOOR SYSTEMS DEMO PLAN - COORDINATION SHACK
SCALE: 1/8" = 1'-0"ED202
5 FIRST FLOOR SYSTEMS DEMO PLAN - UTILITY BUILDING
SCALE: 1/8" = 1'-0"ED202
2 SECOND FLOOR SYSTEMS DEMO PLAN- COORDINATION SHACK
SCALE: 1/8" = 1'-0"ED202
6 FIRST FLOOR SYSTEMS DEMO PLAN- JET SHOP
SCALE: 1/8" = 1'-0"ED202
3 FIRST FLOOR SYSTEMS DEMO PLAN - FOAM ROOM
1 DEMOLISH EXISTING FIRE ALARM AND CONTROL PANEL
AND ALL ASSOCIATED DEVICES REQUIRED FOR
REPLACEMENT OF MAIN PANEL. SEE NEW WORK
DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
DEMOLISH EXISTING FOAM SYSTEM CONTROL PANEL
AND ALL ASSOCIATED DEVICES REQUIRED FOR
REPLACEMENT OF MAIN PANEL. SEE NEW WORK
DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
DEMOLISH EXISTING FOAM SYSTEM START / STOP
STATIONS.
1. EXISTING DEVICES INDICATED SHALL BE REMOVED
AND REPLACED.
DN
DN
UP
R E
F
REF.
F M
F
F
F
F
F
F F M
M M
M
M M
M
FS TS
FS TS
FS TS
FS TS
FS TS
FS TS
FS TS
FS TS
FS TS
FS TS
FS TS
FS TS
FS TS
F F
F F
F F
M M
M M
M M
F F
TS
TS
TS TS
TS TS
TS TS
TS
FS TS
TSTS
FSTS
TS
TS
TS
TS
TS TS
TS
TSTS
FS
FS
FS
FS
A
B
C
D
E
F
G
H
10.5 0.90.80.6 0.7
0.1 0.2 0.3
STORAGE
11 FOAM ROOM
HANGAR
LPK-2 (E)
SWBD. (E)
MCC (E)
CS-1 (E)
CS (E)
LPK-1 (E)
A-2 (E)
E202
E202
E202
E202
E202
177cd
177cd
177cd
177cd
177cd 177cd
177cd
177cd
177cd
177cd
177cd
177cd
177cd
177cd
177cd
177cd
L O
C L O
C
L O
C L O
C
SD SD
SD SD
SD SD
SD SD
SDSD
SD SD
SDSD
SDSD
TYP
TYP
E202
OFD 6
OFD 6
OFD 6
OFD 6
OFD6
OFD6
OFD6
OFD6
EXT.
EXT.
EXT.
EXT.
EXT.
EXT.
T
T
T
T
T
T
(IN PIT)
Scale: 1 / 1 6 " = 1 ' - 0 "
16 ' 64 '32 '8 '0
SCALEGRAPHIC
N
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D A
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
RENOVATION KEY NOTES
GENERAL NOTES
E201
FI
R S T
FL
O O R
S
YS
TE
M S
P
LA
N
B M
P B
M P
A C
N
2/
/2
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
1051184 TWCF
SCALE: 1/16" = 1'-0"E201
1 FIRST FLOOR SYSTEMS PLAN
DUCT SMOKE DETECTORS SHALL BE TIED INTO FIRE ALARM
SYSTEM. COORDINATE EXACT LOCATION OF DETECTORS WITH
MECHANICAL CONTRACTOR.
PROVIDE CEILING MOUNTED NOTIFICATION SPEAKER
CLUSTER. BASIS OF DESIGN: EATON WHEELOCK STH CLUSTER
SPEAKER, STH-4R OR EQUAL.
PROVIDE NEW NEMA 250 TYPE 4 MANUAL FOAM RELEASING
STATIONS AND ZONE LETTERING IN ACCORDANCE WITH UFC
4-211-01 SECTION 3-6.19.8. PROVIDE NEW NEMA 250 TYPE 4
MANUAL FOAM "DEAD-MAN" TYPE STOP STATIONS IN
ACCORDANCE WITH UFC 4-211-01 SECTION 3-6.19.9. PROVIDE
TAMPER COVERS FOR START AND STOP STATIONS THAT EMIT
AN AUDIBLE ALARM WHEN LIFTED. PROVIDE SEPARATE BUT
ADJACENT 24 INCHES HIGH BY 20 INCHES WIDE METAL SIGNS
FOR START AND STOP STATIONS IN ACCORDANCE WITH UFC
4-211-01 SECTION 3-6.19.10. PROVIDE NEW WIRE FROM FOAM
SUPPRESSION SYSTEM CONTROL UNIT TO START AND STOP
STATIONS, AND REROUTE CONDUIT TO NEW LOCATIONS AND
ENTER FROM BELOW.
PROVIDE LISTED / APPROVED FIXED TEMPERATURE SENSORS
SET AT 32°F. LOCATE SENSORS AT THE SAME LEVEL AS THE
ADJACENT SPRINKLER HEAD BRANCHLINE. PROVIDE CENTER
TO CENTER SPACING NOT EXCEEDING 200 FEET OR SPACING
FROM THE WALL NOT EXCEEDING 100 FEET. CONNECT AND
PROGRAM TEMPERATURE SENSORS TO ALARM AS A
SUPERVISORY CONDITION ON THE FIRE ALARM CONTROL
PANEL AND THE ENERGY MANAGEMENT CONTROL SYSTEM IN
ACCORDANCE WITH UFC 4-211-01 SECTION 3-6.15.3.1.
PROVIDE SIGN ON BACKGROUND MATCHING THE MANUAL
FOAM RELEASING STATION SIGNS THAT READS "FOAM
RELEASE WHEN ILLUMINATED" IN RED LETTERING NOT LESS
THAN 3-INCHES HIGH FOR EXISTING ROTATING BLUE BEACONS
IN ACCORDANCE WITH UFC 4-211-01 SECTION 5-6.5.
PROVIDE TRIPLE INFRARED OPTICAL FLAME DETECTORS IN
ACCORDANCE WITH UFC 4-211-01 SECTIONS 3-6.19.11 AND
5-6.3. MOUNT OPTICAL FLAME DETECTOR APPROXIMATELY 8'
ABOVE FINISHED FLOOR. PROVIDE 5' OF FLEXIBLE CONDUIT
TO ALLOW MINOR ADJUSTMENT OF DETECTOR. DETECTORS
SHALL BE ALIGNED SUCH THAT CONE OF VISION STAYS WITHIN
5' OF PERIMETER OF HANGAR OR DOES NOT EXTEND INTO
ANOTHER FIRE AREA. WHERE THE SINGLE AIRCRAFT WING
AREA EXCEEDS 1,000 SF A MINIMUM OF TWO OPTICAL FLAME
DETECTORS COVERING THE SILHOUTTE ARE REQUIRED ON
EACH SIDE OF THE FUSELAGE. ZONE THE DEVICES TO ONLY
RELEASE THE FOAM TO THE ZONE ASSOCIATED WITH THE
FIRE EVENT IN ACCORDANCE WITH UFC 4-211-01 SECTION
3-6.17.1. DETECTORS SHALL BE INSTALLED PER
MANUFACTURER'S INSTRUCTIONS BUT AT A MINIMUM
CONNECTING CONDUITS SHALL BE SEALED TO PREVENT ANY
CONDENSING WATER FROM GETTING INTO DEVICE.
1. CONNECT ALL EXISTING FIRE ALARM DEVICES NOT BEING
DEMOLISHED TO THE NEW FIRE ALARM/ MASS
NOTIFICATION CONTROL PANEL. VERIFY THAT ALL FIRE
ALARM DEVICES EXISTING TO REMAIN FUNCTION
PROPERLY AND REPLACE DEVICES IF NECESSARY.
2. ALL FIRE ALARM CIRCUITING IN HANGAR BAY SHALL BE IN
WATERTIGHT CONDUIT/CONNECTIONS WITH NEMA 4
JUNCTION BOXES, BACK BOXES AND ENCLOSURES.
3. CONDUIT FOR INITIATING DEVICES SHALL ENTER THE
BOTTOM OF THE BACK BOX WITH A DRAIN PROVIDED AT
THE LOW POINT.
4. OPTICAL FLAME DETECTORS SHALL BE X3301 MULTI-
SPECTRUM FLAME DETECTOR MANUFACTURED BY DET-
TRONICS. DETECTORS SHALL BE TRIPLE INFRARED
FLAME DETECTORS LISTED / APPROVED FOR THE
EXPECTED FUEL HAZARD IN THE HANGAR BAY IN
ACCORDANCE WITH UFC 4-211-01 SECTIONS 3-6.19.11 AND
5-6.3.
F M
F
F
M
M
M
F
F
F
F M
M
M
M MF
F F
M
FFS TS
R E
F
REF.
M
M
M
M
M
M F
F
F
F
F
F
F F
FSTS
F
M
M
F
F
TS
TS
TS
TS
TS TS
TS
TSTS
FS
FS
FS
FS
D
COORDINATORS
SHACK
30cd30cd
CS-1 (E)
CS (E)
F
JETS ADMIN.
OFFICE
CONFERENCE
/ BREAK
SHEET
METAL
SHOP
A-2 (E)
15cd15cd
15cd15cd
30cd 30cd
B
C
D
0.1 0.2 0.3
FLIGHT
LEADERSHIP
SECTION
CHIEFS
TOOL ROOM
STORAGE
WOMENS
RESTROOM
LP (E)
30cd 30cd 30cd 30cd
15cd 15cd
75cd 75cd
75cd 75cd
RFAP
E
F
10.5 0.90.80.6 0.7
BREAK
ROOM
RESERVES
OFFICE
MENS
RESTROOM
BOILER
ROOM
SWBD. (E)
MCC (E)
15cd 15cd
15cd15cd
30cd30cd
15cd15cd
15cd15cd
30cd30cd
VEST.
7A
D
OFFICE
CONFERENCE
15cd15cd
15cd15cd
G
1SD
FOAM ROOM
T
PRESSURE
SWITCHES
Scale: 1 / 8 " = 1 ' - 0 "
32 '16 '8 '4 '0
SCALEGRAPHIC
N
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D A
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
RENOVATION KEY NOTES
GENERAL NOTES
E202
S
YS
TE
M S
EN
LA
R G
ED
P
LA
N S
B M
P B
M P
A C
N
2/
/2
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
1051184 TWCF
SCALE: 1/8" = 1'-0"E202
1 FIRST FLOOR SYSTEMS PLAN - COORDINATION SHACK
SCALE: 1/8" = 1'-0"E202
5 FIRST FLOOR SYSTEMS PLAN - JET SHOP
SCALE: 1/8" = 1'-0"E202
3 FIRST FLOOR SYSTEMS PLAN - OFFICE BUILDING
SCALE: 1/8" = 1'-0"E202
4 FIRST FLOOR SYSTEMS PLAN - UTILITY BUILDING
SCALE: 1/8" = 1'-0"E202
2 SECOND FLOOR SYSTEMS PLAN- COORDINATION SHACK
1 PROVIDE NEW POINT TO POINT MONACO MAAP-X FIRE
ALARM/MASS NOTIFICATION PANEL. CONFIGURE PANEL TO
BE COMPATIBLE WITH JOINT BASE CHARLESTON CENTRAL
STATION D-21. CONNECT TO EXISTING POWER SERVING
DEMOLISHED PANEL.
LOCATE FOAM SYSTEM RELEASING AND MONITOR
MODULES INTEGRAL TO THE RELEASE OF THE FOAM
SYSTEM APPROXIMATELY IN THIS LOCATION.
PROVIDE KEY OPERATED SUPERVISED DISCONNECT
SWITCH FOR EACH OF THE THREE FOAM RISERS TO
PHYSICALLY DISABLE THE SOLENOID. PROVIDE SWITCH
THAT DISABLES THE RELEASING FUNCTIONS WITHOUT THE
USE OF PROGRAMMING, WHILE LEAVING ALL OTHER
FUNCTIONS OF THE PANEL OPERATIONAL. MONITOR
DISCONNECT SWITCHES AT THE FOAM SYSTEM CONTROL
PANEL FOR A SUPERVISORY SIGNAL.
PROVIDE A SIGN FOR EACH FOAM/WATER RISER
DISCONNECT SWITCH. SIGN SHALL HAVE WHITE
BACKGROUND, MINIMUM 1/2-INCH WIDE BLUE BORDER
LABELED "DISABLE FOAM SYSTEM" IN RED LETTERING NOT
LESS THAN 1-INCH HIGH. LABELS ON DISCONNECT
SWITCHES SHALL ALSO INDICATE WHEN THE SWITCH IS
"ENABLED" OR "DISABLED". SIGNS SHALL NOT BE
OBSTRUCTED IN ANY MANNER.
SWITCHES AND SIGNS SHALL BE IN ACCORDANCE WITH
UFC 4-211-01 SECTION 3-6.19.2.3
NEW FOAM SUPPRESSION CONTROL PANEL (FSCP) SHALL
BE DET-TRONICS EAGLE QUANTUM PREMIER FIRE
DETECTION / RELEASING SYSTEM. SEE 21 13 25 HIGH
EXPANSION FOAM SYSTEM, FIRE PROTECTION,
SPECIFICATION FOR ADDITIONAL INFORMATION. NEW
PANEL LOCATION SHALL MAINTAIN ALL REQUIRED
CLEARANCES.
PROVIDE LISTED/APPROVED FIXED TEMPERATURE
SENSORS SET AT 32°F. LOCATE AT THE SAME LEVEL AS
THE ADJACENT SPRINKLER HEAD BRANCHLINE. CONNECT
AND PROGRAM TEMPERATURE SENSORS TO ALARM AS A
SUPERVISORY CONDITION ON THE FIRE ALARM CONTROL
PANEL AND THE ENERGY MANAGEMENT CONTROL SYSTEM
IN ACCORDANCE WITH UFC 4-211-01 SECTION 3-6.7.2.
SCALE: 1/8" = 1'-0"E202
6 FIRST FLOOR SYSTEMS PLAN - FOAM ROOM
ALL PENETRATIONS THROUGH FOAM ROOM 12 SHALL
MAINTAIN A 1-HOUR RATING.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIRE
WATCHES NECESSARY TO CHANGE OUT EXISTING FIRE
ALARM SYSTEM.
1.
2.
DN
DN
UP
R E
F
REF.
A
B
C
D
E
F
G
H
10.5 0.90.80.6 0.7
0.1 0.2 0.3
FLIGHT
LEADERSHIP
SECTION
CHIEFS
TOOL ROOM
STORAGE
WOMENS
RESTROOM
BREAK
ROOM
RESERVES
OFFICE
MENS
RESTROOM
BOILER
ROOM
STORAGE
FOAM ROOM
HANGAR
SHEET
METAL
SHOP
COORDINATORS
SHACK
CONFERENCE
/ BREAK
JETS ADMIN.
OFFICE
VEST.
7A
KITCHEN
7B
STO.
7C
FDC
FP100
FP100
G
FOAM ROOM
10" FS
3" FS
EXISTING 800 GALLON
HORIZONTAL FOAM
STORAGE TANK
(E) 3" FS
GG
EXISTING 800 GALLON
HORIZONTAL FOAM
STORAGE TANK
(E) 10" FS
(E) 3" FS
(E) 6" FS(E) 6" FS(E) 6" FS
FOAM ROOM
GENERAL FIRE PROTECTION NOTES
1. EXISTING WET PIPE SPRINKLER SYSTEM AND HIGH EXPANSION FOAM SYSTEM
ARE EXISTING TO REMAIN, EXCEPT FOR MODIFICATIONS NOTED HEREIN.
2. DO NOT SCALE DRAWINGS. ROUGH FROM ARCHITECTURAL AND EQUIPMENT
MANUFACTURER'S DRAWINGS. COORDINATE CEILING FINISHES AND HEIGHTS AS
APPLICABLE.
3. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH NFPA 13 AND ALL
APPLICABLE LOCAL CODES AND ORDINANCES.
4. COORDINATE SPRINKLER SYSTEMS WITH ALL TRADES TO AVOID INTERFERENCE
AND CONFLICTS PRIOR TO INSTALLATION OF PIPING, VALVES, AND EQUIPMENT.
5. LOCATE VALVES TO PERMIT EASY ACCESSIBILITY AND IN ACCORDANCE WITH
NFPA 13.
6. WHENEVER THE WORD "PROVIDE" IS USED, IT SHALL MEAN FURNISH AND INSTALL
COMPLETE AND READY FOR USE.
7. UNLESS OTHERWISE SHOWN OR NOTED, ALL PIPING SHALL BE RUN CONCEALED
IN WALLS, CHASES, AND/OR ABOVE CEILINGS.
8. PROVIDE SEISMIC BRACING ON ANY MODIFIED SPRINKLER MAINS PER NFPA 13.
9. ALL SITE UTILITIES ARE SHOWN IN APPROXIMATE LOCATIONS ONLY. VERIFY
EXACT LOCATION AND INVERT ELEVATION IN FIELD BEFORE BEGINNING WORK.
10. ALL SUSPENDED PIPING SHALL BE SUPPORTED FROM FLOOR AND/OR ROOF
STRUCTURAL MEMBERS. IN NO CASE SHALL PIPING BE SUSPENDED FROM FLOOR
AND ROOF DECK.
11. ALL PIPING IN AREAS WITH EXPOSED STRUCTURE SHALL BE INSTALLED TIGHT TO
EXPOSED BEAMS. EXACT LOCATIONS IN PLAN AND ELEVATION SHALL BE
COORDINATED WITH THE GOVERNMENT DURING THE SHOP DRAWING REVIEW
PHASE.
12. ALL WORK AND SYSTEM OUTAGES SHALL BE COMPLETED IN ACCORDANCE WITH
NFPA 25 AND SHALL BE FULLY COORDINATED WITH THE GOVERNMENT.
13. CONTRACTOR SHALL CONDUCT FLOW TEST TO OBTAIN RECENT FIRE FLOW TEST
DATA. CONTRACTOR SHALL PERFORM AND PROVIDE ALL REQUIRED HYDRAULIC
CALCULATIONS, HIGH-EXPANSION FOAM DISCHARGE RATE CALCULATIONS, AND
FOAM SPREAD CALCULATIONS FOR MODIFIED SYSTEM USING THE FIRE FLOW
TEST DATA IN ACCORDANCE WITH UFC 4-211-01 SECTION 3-6.18. IF FIRE FLOW
TEST DATA IS MORE THAN 12 MONTHS OLD THE CONTRACTOR SHALL PERFORM A
NEW FIRE FLOW TEST.
14. COORDINATE SPRINKLER SYSTEMS WITH STRUCTURE AND ALL OTHER TRADES TO
AVOID INTERFERENCE AND CONFLICTS PRIOR TO INSTALLATION OF PIPING,
VALVES, AND EQUIPMENT.
15. PROVIDE UL RATED FIRE AND SMOKE PENETRATION FIRESTOPPING SYSTEMS FOR
ALL PENETRATIONS OF FIRE RATED ASSEMBLIES.
16. FIRE SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED
SUBMITTALS TO GOVERNMENT FOR PERMITTING AND ANY OTHER REQUIRED
SUBMITTALS OR APPROVALS. FIRE SPRINKLER SHOP DRAWINGS, PRODUCT DATA,
HYDRAULIC CALCULATIONS, HIGH-EXPANSION FOAM DISCHARGE RATE
CALCULATIONS, FOAM SPREAD CALCULATIONS, AND SEISMIC CALCULATIONS
SHALL BE REVIEWED AND STAMPED/SIGNED BY THE FIRE PROTECTION
SPECIALIST AND SUBMITTED TO THE GOVERNMENT AND FIRE PREVENTION
OFFICE FOR REVIEW. ALL SUBMITTALS MUST BE COMPLETED IN ACCORDANCE
WITH UFC 3-600-1 SECTION 9-6.3.
17. SPRINKLER PIPING SHALL BE U.L. LISTED. PIPING SHALL BE A MINIMUM SCHEDULE
40 BLACK STEEL.
18. COORDINATE WORK WITH GOVERNMENT. OBTAIN ALL PERMITS AND PASS ALL
INSPECTIONS FROM GOVERNMENT.
NOTE TO AUTHORITY HAVING JURISDICTION
FIRE SPRINKLER SHOP DRAWINGS AND CALCULATIONS ARE A
DELEGATED DESIGN. SPRINKLER CONTRACTOR SHALL SUBMIT
SHOP DRAWINGS AND CALCULATIONS TO GOVERNMENT AND FIRE
PREVENTION OFFICE PRIOR TO START OF SPRINKLER WORK. SHOP
DRAWINGS AND CALCULATIONS SHALL BE REVIEWED ANS
STAMPED/SIGNED BY A FIRE PROTECTION ENGINEER IN
ACCORDANCE WITH UFC 3-600-01.
Scale: 1 / 1 6 " = 1 ' - 0 "
16 ' 64 '32 '8 '0
SCALEGRAPHIC
N
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D A
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
RENOVATION KEY NOTES
GENERAL NOTES
FP100
FI
R E P R O
TE
C
TI
O N
P
LA
N
C G
G C
G G
M G
W
1/
/2
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
1051184 TWCF
SCALE: 1/16" = 1'-0"FP100
1 FIRE PROTECTION PLAN
MODIFY WATER PIPING TO BLADDER TANK AS SHOWN TO
CONNECT DOWNSTREAM OF DELUGE VALVES IN
ACCORDANCE WITH UFC 4-211-01 SECTION 5-6.7.7.
TEST ALL RISERS TO VERIFY OPERATION OF FLOW
SWITCH, ALARM SYSTEM, AND ACCESSORIES. TEST OS&Y
VALVES, SUPERVISORY SWITCHES AND MONITOR
CIRCUITS. PROVIDE NEW RISER AND VALVE TAGS.
REPLACE ANY COMPONENTS THAT FAIL INSPECTION.
APPROXIMATE LOCATIONS OF EXISTING FOAM
GENERATORS. RELOCATE EXISTING FOAM GENERATORS
TO DISCHARGE FOAM WITHIN CLOSE PROXIMITY BUT NOT
DIRECTLY ONTO AIRCRAFT OR SURROUNDING
MAINTENANCE PLATFORMS. NEW LOCATIONS SHALL BE
DETERMINED BY THE CONTRACTOR IN ACCORDANCE WITH
UFC 4-211-01 SECTION 3-6.17.4. PROVIDE A FOAM SPREAD
CALCULATION / DIAGRAM DEMONSTRATING THE
PERFORMANCE REQUIREMENTS TO COVER THE AIRCRAFT
SILHOUETTE ARE MET WITHIN ONE MINUTE IN
ACCORDANCE WITH UFC 4-211-01 SECTION 3-6.18.
RELOCATE EXISTING W14x26 SUPPORT BEAMS, (2) PER
FOAM GENERATOR, AND SEISMICALLY RESTRAIN FOAM
GENERATOR IN NEW LOCATION. FIELD VERIFY LOCATION
OF FOAM GENERATORS AND COORDINATE AIRCRAFT
LOCATIONS WITH GOVT.
PROVIDE BASKET STRAINER ON INCOMING FIRE WATER
LINE IN ACCORDANCE WITH UFC 4-211-01 SECTION 3-6.8.3.
DEMOLISH EXISTING 10 GALLON SURGE ARRESTOR AND
PROVIDE MINIMUM 25 GALLON SURGE ARRESTOR WITH A
A MINIMUM RATED WORKING PRESSURE OF 275 PSI IN
ACCORDANCE WITH UFC 4-211-01 SECTION 3-6.5.
RECONNECT TO EXISTING PIPING.
CAP PIPE AT HEADER.
REPLACE EXISTING DELUGE VALVE WITH A FLOW
CONTROL VALVE WITH REMOTE RESETTING CAPABILITY,
AUTOMATIC RE-CLOSING FEATURE, AND ADJUSTABLE
SPEED CONTROL IN ACCORDANCE WITH UFC 4-211-01
SECTION 3-6.9.
1. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL
INFORMATION.
2. SEE SPECIFICATIONS FOR SYSTEM TESTING
REQUIREMENTS.
3. LABEL NEW PIPING WITH PLASTIC WRAP AROUND-TYPE
PIPE LABELS CONFORMING TO ASME A13.1 IN
ACCORDANCE WITH UFC 4-211-02 SECTION 3-6.8.1.
4. PROVIDE SIGNAGE FOR EMERGENCY FOAM SHUTDOWN
PROCEDURE IN ACCORDANCE WITH UFC 4-211-01 SECTION
3-6.19.15.4.
SCALE: 1/4" = 1'-0"FP100
3 FIRE PROTECTION FOAM ROOM ENLARGED RENOVATION PLAN
SCALE: 1/4" = 1'-0"FP100
2 FIRE PROTECTION FOAM ROOM ENLARGED DEMOLITION PLAN
FIRE PROTECTION CODES AND STANDARDS
CODE DESCRIPTION
ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES
NFPA 1 (2018) FIRE CODE
NFPA 13 (2019) STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
NFPA 101 (2018) LIFE SAFETY CODE
UFC 3-600-01
(10 MAY 2019)
UNITED FACILITIES CRITERIA - FIRE PROTECTION ENGINEERING
FOR FACILITIES
UFC 4-211-01
(13 APRIL 2017)
AIRCRAFT MAINTENANCE HANGARS
FIRE PROTECTION ABBREVIATIONS
ABBR DESCRIPTION
(E) EXISTING
FDC FIRE DEPARTMENT CONNECTION
FEC FIRE EXTINGUISHER CABINET
GPM GALLONS PER MINUTE
HR HOUR
MIN MINUTE
SF SQUARE FOOT
UNO UNLESS NOTED OTHERWISE
W/ WITH
CONNECT TO EXISTING
1/29/2021
T
DN
T
G
FOAM ROOM
(E) AHU-1
(E) HP-1
G
FOAM ROOM
AH-1
3/4" D
HP-1
NOTES:
H = FAN STATIC PRESSURE
(IN. W.C.) + 1 IN.
3.
ACCESSIBLE FOR CLEANING.
2. "RUNNING" TYPE TRAPS SHALL
BE UNACCEPTABLE.
1. LOCATE TRAPS SO AS TO BE
PIPE FULL SIZE OF
UNIT DRAIN
UNIT CASING
SCREWED CAP
OPEN END (VENT)
J = H/2 (MINIMUM)4.
J
H
Scale: 1 / 4 " = 1 ' - 0 "
SCALEGRAPHIC
16 '8 '4 '2 '0
R
No.
K
TU
S
A
M K
Y A. U
A
A
27045
RCAH OL INN
E E
D
R
P
F ESS IO O
E C
S N
E I L R
L A
G I
E N
N
O
N
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D A
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K B
Y:
D
R
AW
N B
Y:
D
S G
N B
Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
RENOVATION KEY NOTES
GENERAL NOTES
M100
M
EC
H
AN
IC
AL
FO
AM
R O O M
P
LA
N
C G
G C
G G
M A
U
1/
/2
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
R
EP
AI
R
AI
R C R
AF
T M
AI
N
TE
N
AN
C E
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
H
AN
G
ER
FI
R E S
YS
TE
M S
B
LD
G
1051184 TWCF
1/29/2021
SCALE: 1/4" = 1'-0"M100
1 MECHANICAL FOAM ROOM DEMOLITION PLAN
SCALE: 1/4" = 1'-0"M100
2 MECHANICAL FOAM ROOM RENOVATION PLAN
EXISTING EQUIPMENT PAD TO REMAIN. PROVIDE SEISMIC
RESTRAINT FOR NEW HEAT PUMP TO EXISTING PAD.
ROUTE NEW CONDENSATE PIPING THROUGH EXISTING
PENETRATION AND TERMINATE ABOVE PAVEMENT. SEAL
PENETRATION AIR TIGHT. FIRESTOP PENETRATION WITH
U.L. LISTED FIRE STOPPING MATERIAL TO MAINTAIN 1
HOUR FIRE RATING OF THE WALL.
ROUTE NEW REFRIGERANT LINESET THROUGH EXISTING
PENETRATION. FOLLOW MANUFACTURER'S
RECOMMENDATIONS FOR SIZING OF LINESET. SEAL
PENETRATION AIR TIGHT. FIRESTOP PENETRATION WITH
U.L. LISTED FIRE STOPPING MATERIAL TO MAINTAIN 1
HOUR FIRE RATING OF THE WALL. PROVIDE ALUMINUM
JACKETING ON EXTERIOR INSULATION.
PROVIDE NEW WALL MOUNTED TEMPERATURE SENSOR
TIED TO THE ENERGY MANAGEMENT CONTROL SYSTEM TO
CONTROL THE MINI-SPLIT.
1. DEMOLISH EXISTING EQUIPMENT AND PIPING AS SHOWN.
2. PROVIDE 1 INCH FLEXIBLE ELASTOMERIC INSULATION ON
REFRIGERANT SUCTION PIPING AND CONDENSATE PIPING.
3. COORDINATE WITH FIRE ALARM CONTRACTOR TO HAVE
FIXED TEMPERATURE SENSORS IN HANGER AND FOAM
ROOM ALARM THE ENERGY MANAGEMENT CONTROL
SYSTEM WHEN THE TEMPERATURE DROPS BELOW 32°F.
SEE ELECTRICAL DRAWINGS FOR ADDITIONAL
INFORMATION.
DUCTLESS MINI-SPLIT SYSTEM SCHEDULE
INDOOR
UNIT MARK
OUTDOOR
UNIT MARK
MAXIMUM AIRFLOW
(CFM)
MAX COOLING
CAPACITY @ 95°F
(MBH)
MIN COOLING
CAPACITY @ 95°F
(MBH)
ENTERING AIR TEMP
SEER
MAX HEATING
CAPACITY @ 17°F
(MBH)
BASIS OF
DESIGN INDOOR MODEL OUTDOOR MODELDB WB
AH-1 HP-1 590 24 6.4 80 °F 67 °F 16 18.6 TRANE 4MXW6524A1 4TXK6524A1
NOTES:
1. SEE ELECTRICAL DRAWINGS FOR VOLTAGE REQUIREMENTS.
2. PROVIDE SEACOAST COATING ON CONDENSER COILS.
3. CONNECT TO EXISTING ENERGY MANAGEMENT CONTROL SYSTEM TO MONITOR ROOM TEMPERATURE, UNIT STATUS, ALL ALARMS, AND TO SET THE ROOM TEMPERATURE SETPOINT.
NOT TO SCALE
M100
3 CONDENSATE DRAIN TRAP INSTALLATION DETAIL
| 1 of 8 - G000 - COVER SHEET |
| Sheets |
| E200 - ELECTRICAL NOTES & FOAM ROOM POWER PLAN |
| E201 - FIRST FLOOR SYSTEMS PLAN |
| E202 - SYSTEMS ENLARGED PLANS |
| ED201 - FIRST FLOOR SYSTEMS DEMO PLAN |
| ED202 - SYSTEMS ENLARGED DEMO PLANS |
| FP100 - FIRE PROTECTION PLAN |
| G000 - COVER SHEET |
| M100 - MECHANICAL FOAM ROOM PLAN |
| 2 of 8 - E200 - ELECTRICAL NOTES & FOAM ROOM POWER PLAN |
| Sheets |
| E200 - ELECTRICAL NOTES & FOAM ROOM POWER PLAN |
| E201 - FIRST FLOOR SYSTEMS PLAN |
| 3 of 8 - ED201 - FIRST FLOOR SYSTEMS DEMO PLAN |
| Sheets |
| E200 - ELECTRICAL NOTES & FOAM ROOM POWER PLAN |
| E201 - FIRST FLOOR SYSTEMS PLAN |
| E202 - SYSTEMS ENLARGED PLANS |
| ED201 - FIRST FLOOR SYSTEMS DEMO PLAN |
| ED202 - SYSTEMS ENLARGED DEMO PLANS |
| FP100 - FIRE PROTECTION PLAN |
| G000 - COVER SHEET |
| M100 - MECHANICAL FOAM ROOM PLAN |
| 4 of 8 - ED202 - SYSTEMS ENLARGED DEMO PLANS |
| Sheets |
| E201 - FIRST FLOOR SYSTEMS PLAN |
| E202 - SYSTEMS ENLARGED PLANS |
| ED202 - SYSTEMS ENLARGED DEMO PLANS |
| 5 of 8 - E201 - FIRST FLOOR SYSTEMS PLAN |
| Sheets |
| E200 - ELECTRICAL NOTES & FOAM ROOM POWER PLAN |
| E201 - FIRST FLOOR SYSTEMS PLAN |
| 6 of 8 - E202 - SYSTEMS ENLARGED PLANS |
| Sheets |
| E201 - FIRST FLOOR SYSTEMS PLAN |
| E202 - SYSTEMS ENLARGED PLANS |
| ED202 - SYSTEMS ENLARGED DEMO PLANS |
| 7 of 8 - FP100 - FIRE PROTECTION PLAN |
| Sheets |
| E200 - ELECTRICAL NOTES & FOAM ROOM POWER PLAN |
| E201 - FIRST FLOOR SYSTEMS PLAN |
| E202 - SYSTEMS ENLARGED PLANS |
| ED201 - FIRST FLOOR SYSTEMS DEMO PLAN |
| ED202 - SYSTEMS ENLARGED DEMO PLANS |
| FP100 - FIRE PROTECTION PLAN |
| G000 - COVER SHEET |
| M100 - MECHANICAL FOAM ROOM PLAN |
| 8 of 8 - M100 - MECHANICAL FOAM ROOM PLAN |
| Sheets |
| M100 - MECHANICAL FOAM ROOM PLAN |
File details come from the government source that posted it. Updated .