22 of 056 - A100 - FIRST FLOOR PLAN Rev 01 2021-07-13.pdf
PDF 250 KB Posted
- Attached to
- Repair Maintenance Hanger, Bldg 700
- Solicitation number
- FA441821R0015
About this file
This set of architectural drawings and federal contract opportunity solicitation provide details for repair and maintenance work at Hangar 700 at Joint Base Charleston - Air Base Charleston in South Carolina. The architectural drawings show the existing first floor plan and include notes specifying finishes, materials, and scope of work such as removing and replacing caulk containing asbestos. The related solicitation FA441821R0015 from the Department of the Air Force Air Mobility Command is for repair and maintenance of the hangar building. The opportunity involves general repairs and upgrades to building systems along with hazardous material abatement activities. The response date is not stated.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
DN
DN
DN
UP
R
EF
REF.
DN
A200
A200
A201
A201
HANGAR
SECTION CHIEFS
3FLIGHT LEADERSHIP
TOOL ROOM
STORAGE
WOMENS RESTROOM
BREAK ROOM
RESERVES OFFICE
MENS RESTROOM
BOILER ROOM
STORAGE
FOAM ROOM
SHEET METAL SHOP
515.24 SF
COORDINATORS
SHACK
A420
A421
A100 A101
A100 A101
CONFERENCE / BREAK
JETS ADMIN.
OFFICE
13' - 8"
9.31
EXISTING
2.32
EXISTING
2.32
9.32
2.38
2.38
2.38
2.38
2.38
2.38 2.38
2.38
9.34
REFER TO GEN. NOTE 11,
THIS SHEET.
REFER TO GEN. NOTE 11,
THIS SHEET.
REFER TO GEN. NOTE 11,
THIS SHEET.
GENERAL FLOOR PLAN NOTES:
1. DIMENSIONS INDICATED ARE FROM FACE OF STUD AND TO FACE OF
MASONRY, U.O.N. REFER TO ENLARGED PLANS FOR ADDITIONAL
DIMENSIONS NOT INDICATED ON OVERALL PLANS.
2. DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, U.O.N.
3. CONTRACTOR TO COORDINATE LOCATIONS OF ADDITIONAL
PENETRATIONS THROUGH WALLS AND FLOORS NOT INDICATED ON
ARCHITECTURAL DRAWINGS. RE: MECHANICAL, PLUMBING AND
ELECTRICAL. REFER TO STRUCTURAL FOR LINTEL OR FRAMING
REQUIREMENTS.
4. ALL NEW WALLS ARE TO BE TYPE H2, U.O.N.
5. CONTRACTOR TO PAINT ALL INTERIOR WALLS OF ONE STORY BUILDING.
PATCH AND REPAIR ANY DAMAGE TO GYPSUM BOARD WALLS PRIOR
TO PAINTING.
6. GC TO PROVIDE SAMPLES OF ALL INTERIOR AND EXTERIOR COLORS AND
FINISHES. SAMPLES TO INCLUDE MANUFACTURER, BRAND, PATTERN,
NUMBER, AND COLOR.
7. WALL FINISH IN SHOWER 20 TO BE WFP1.
8. WHERE CT-1 AND CT-2 OCCUR, GROUT COLOR SHALL MATCH LATTICRETE
COLOR "RAVEN".
9. ALL PENETRATIONS THROUGH FIRE RATED WALL TO BE SEALED WITH
FIRE CAULK.
10. CAULK CONTAINING ASBESTOS IS PRESENT AROUND EXISTING EXTERIOR
WALL LOUVERS. REFER TO SPECIFICATION SECTION 02 82 16.00 FOR
DETAILS. SCOPE INCLUDES REMOVING AND REPLACING CAULK.
11. HANGAR DOOR BUMPERS AND WALL GUARDS AT THRESHOLD OF SMALL
ROLL-UP DOOR ON WEST SIDE ARE COATED WITH LEAD-BASED PAINT.
EMPLOY WET METHODS TO PREPARE SURFACES FOR REPAINTING.
PAINT WASTE FROM SURFACE PREPARATIONS SHALL BE DISPOSED AS
HAZARDOUS WASTE. REFER TO LIMITED ASBESTOS AND LEAD-BASED
PAINT ASSESSMENT REPORT AND SUPPLEMENTAL ASBESTOS AND LEAD-
BASED PAINT TESTING REPORT FOR LOCATIONS.
INDICATES 1-HR FIRE RATED WALL
OFFICE
CONFERENCE
H1 NON-RATED METAL STUD WALL
SOUND RATING: STC ____
EXTEND TO STRUCTURE ABOVE
FIRE RATING: N/A
5/8" GYP. BD.
3 5/8" METAL
STUD @ 16" O.C.,
U.O.N.
H2 NON-RATED METAL STUD WALL
EXTEND TO 6" ABOVE CEILING
SOUND RATING: ____
FIRE RATING: N/A
5/8" GYP. BD.
3 5/8" METAL
STUD @ 16" O.C.,
U.O.N.
CHARLESTON
NO. 2676
GARY J. BOEHMST
AT
E OF SOUTH CAROLINA
REGISTERED A RCHITECT
G
E W
BAIR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T H E
AI
R
FO
RC
E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N
BY
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
A B
C H A R
LE
S
TO
N S C
ARCH30 E(30X42)
OF 056SHEET
A100
FI
RS
T
FL
OO
R
PL
AN
De sig ne r
Au tho r Ch ec ke r
/27
/17
JB
C
AB
B
RE
PA
IR
A
IR
C
RA
FT
M
AI
NT
EN
AN
C E H
AN
GE
R
DKGV:DKFX 11-1171
SCALE: 1/16" = 1'-0"A101 A100
1 FIRST FLOOR PLAN
PROJ.TRUE
0' 8' 16' 32' 64'
KEYNOTE LEGEND
Key Value Keynote Text
2.32 EXISTING STEEL LADDER, TO REMAIN. PAINT.
2.38 EXISTING HVAC UNIT, RE: MECH.
9.31 ROUGH, NON-SKID FLOOR SURFACE: EF-1 WITH COVE
BASE.
9.32 INDUSTRIAL NON-SKID, ROUGH SURFACE TILE
FLOORING, QT-1. PROVIDE MATCHING BASE.
9.34 INFILL AND PATCH WALL AT LOCATIONS OF DUCT
REMOVAL, RE: MECH. MATCH CONSTRUCTION AND
FINISH OF EXISTING WALL.
SCALE: 1/16" = 1'-0"A201 A100
2 SECOND FLOOR PLAN
SCALE: 1 1/2" = 1'-0"
WALL TYPE H1 - H2
AD
DE
ND
UM
7/
/2
| Sheets |
| A100 - FIRST FLOOR PLAN |
| A101 - FLOOR PLANS - 1 STORY AREA |
File details come from the government source that posted it. Updated .