23 of 56 - A101 - FLOOR PLANS - 1 STORY AREA Rev 01 2021-07-13 (Q10).pdf

PDF 311 KB Posted

Attached to
Repair Maintenance Hanger, Bldg 700
Solicitation number
FA441821R0015
Issued by

About this file

This document package includes floor plans and specifications for repair work on an aircraft maintenance hangar building at Joint Base Charleston-Air Base Charleston in South Carolina. The project involves repairing and renovating several areas of the one-story building, including restrooms, a break room, storage areas, and installing a new ADA-compliant shower. Finishes, fixtures, casework and other interior elements are specified. The floor plans provide dimensions, notes and details for the scope of work. This appears to relate to solicitation number FA441821R0015 issued by the Department of the Air Force Air Mobility Command for repair and maintenance of Building 700 at the base.

View the file

Other files

File Type Posted
Solicitation Amendment FA441821R00150002 SF 30.pdf PDF
18 of 56 - AD120 - DEMOLITION CEILING PLAN Rev 01 2021-07-13.pdf PDF
Roofing Q19.pdf PDF
17 of 56 - AD100 - DEMOLITION PLAN Rev 01 2021-07-13 (Q10).pdf PDF
6 of 056 - S101 - Foundation Plan Rev 01 2021-07-13 (Q7 and Q10).pdf PDF
01 30 00 Rev01 2021-07-15.pdf PDF
5 of 056 - S000 - General Notes Rev 01 2021-07-13 (Q13).pdf PDF
8 of 056 - S201 - Typical Foundation Details Rev 01 2021-07-13.pdf PDF
22 of 056 - A100 - FIRST FLOOR PLAN Rev 01 2021-07-13.pdf PDF
B700 Pre-Proposal Questions and Answers 27 Jul 2021.xlsx XLSX spreadsheet
Solicitation Amendment FA441821R00150001 SF 30.pdf PDF
Q and A Attachment 1 233113 Metal Ducts - Rectangular Double Wall.pdf PDF
Q and A Attachment 2 Answer to Question 16.png PNG image
B700 Pre-Proposal Questions and Answers.xlsx XLSX spreadsheet
JB Charleston - Offeror Inquiry Form FA44182R0015.xlsx XLSX spreadsheet
Attachment 7 WD SC20210023.pdf PDF
Attachment 2 Design Narrative Maintenance Hangar B700.pdf PDF
Attachment 3 Repair Aircraft Maint Hanger Drawing Set.pdf PDF
Attachment 5 Repair Aircraft Maint Hangar Fire Systems B700 Drawing Set.pdf PDF
Attachment 8 Green Procurement Form.pdf PDF
Attachment 9 Past Performance Questionnaire.pdf PDF
Attachment 4 Design Narrative Repair Aircraft Maint Hangar Fire Systems B700.pdf PDF
Attachment 6 Asbestos and Lead Based Paint Survey Report.pdf PDF
Solicitation - FA441821R0015 FINAL.pdf PDF
Attachment 1 Specs Repair Aircraft Maint Hangar B700.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R

EF

REF.

GENERAL FLOOR PLAN NOTES:

1. DIMENSIONS INDICATED ARE FROM FACE OF STUD AND TO FACE OF

MASONRY, U.O.N. REFER TO ENLARGED PLANS FOR ADDITIONAL

DIMENSIONS NOT INDICATED ON OVERALL PLANS.

2. DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH, U.O.N.

3. CONTRACTOR TO COORDINATE LOCATIONS OF ADDITIONAL

PENETRATIONS THROUGH WALLS AND FLOORS NOT INDICATED ON

ARCHITECTURAL DRAWINGS. RE: MECHANICAL, PLUMBING AND

ELECTRICAL. REFER TO STRUCTURAL FOR LINTEL OR FRAMING

REQUIREMENTS.

4. ALL NEW WALLS ARE TO BE TYPE H2, U.O.N.

5. CONTRACTOR TO PAINT ALL INTERIOR WALLS OF ONE STORY BUILDING.

PATCH AND REPAIR ANY DAMAGE TO GYPSUM BOARD WALLS PRIOR

TO PAINTING.

6. GC TO PROVIDE SAMPLES OF ALL INTERIOR AND EXTERIOR COLORS AND

FINISHES. SAMPLES TO INCLUDE MANUFACTURER, BRAND, PATTERN,

NUMBER, AND COLOR.

7. WALL FINISH IN SHOWER 20 TO BE WFP1.

8. WHERE CT-1 AND CT-2 OCCUR, GROUT COLOR SHALL MATCH LATTICRETE

COLOR "RAVEN".

9. ALL PENETRATIONS THROUGH FIRE RATED WALL TO BE SEALED WITH

FIRE CAULK.

10. CAULK CONTAINING ASBESTOS IS PRESENT AROUND EXISTING EXTERIOR

WALL LOUVERS. REFER TO SPECIFICATION SECTION 02 82 16.00 FOR

DETAILS. SCOPE INCLUDES REMOVING AND REPLACING CAULK.

11. HANGAR DOOR BUMPERS AND WALL GUARDS AT THRESHOLD OF SMALL

ROLL-UP DOOR ON WEST SIDE ARE COATED WITH LEAD-BASED PAINT.

EMPLOY WET METHODS TO PREPARE SURFACES FOR REPAINTING.

PAINT WASTE FROM SURFACE PREPARATIONS SHALL BE DISPOSED AS

HAZARDOUS WASTE. REFER TO LIMITED ASBESTOS AND LEAD-BASED

PAINT ASSESSMENT REPORT AND SUPPLEMENTAL ASBESTOS AND LEAD-

BASED PAINT TESTING REPORT FOR LOCATIONS.

INDICATES 1-HR FIRE RATED WALL

E

F

G

BREAK ROOM

RESERVES OFFICE

MENS RESTROOM

BOILER ROOM

STORAGE

SHOWER

2.43

2.43

2.43

2.43

2.43

2.372.37

9.06

9.01

9.33

22.01

22.08

22.11

8 3/8"

10.30 10.31

9.06

VEST.

7A

KITCHEN

7B

STO.

7C

9.06

9.06

9.34

VFY DIMS W/

SHOWER UNIT

2.39

2.40

22.11

22.11B

10.114'-0 1/2"

J2

3'

3"

ALL PLUMBING

FIXTURES IN THIS

ROOM TO BE

REPLACED, RE:

PLUMBING

A

B

C

D

SECTION CHIEFS

FLIGHT LEADERSHIP

TOOL ROOM

STORAGE

5 WOMENS RESTROOM

9.01 9.01

2.43

2.43

2.43

2.43

2.372.37

22.01

9.31

A.1

A.3

A.2

0.1 0.2 0.3

A101A101

EXISTING

2.32

5' - 4"

19' - 6 1/4" 4' - 3"

W1

9.34

1'

/6 4"4

A101 A101

EXISTING OIL INTERCEPTOR,

TANK, HATCH AND VENTS SHALL

BE PROTECTED DURING

CONSTRUCTION PROCESS

1 24

5/

5'

1/

8"

5'

0"

28' - 9 1/4"

PAINT (PNT)

MANUFACTURER:

COLOR:

PNT-2

PNT-1 MANUFACTURER:

COLOR:

MANUFACTURER:

STYLE:

COLOR:

SIZE:

CERAMIC TILE (CT)

CT-1 DALTILE

SANDALO

CASTILLIAN GRAY

2X2 MOSAIC

INTERIOR FINISH LEGEND

MANUFACTURER:

PATTERN:

CARPET (CPT)

CPT-1 MILLIKEN

SCATTERGRAPH

SCA107-108

HYPERPLANE

50cmX50xm TILE

INSTALLED RANDOM

SHERWIN WILLIAMS

PURE WHITE 7005

RUBBER BASE (RB)

RB-1 MANUFACTURER:

STYLE:

COLOR:

JOHNSONITE

4" RUBBER BASE

280 SHORELINE

(MANUFACTURER & COLOR-BASIS OF DESIGN)

EPOXY FLOORING (EF)

EF-1 MANUFACTURER:

STYLE:

COLOR:

DURA-A-FLEX

POLY-CRETE SLB

DARK GREY

ACOUSTICAL CEILING TILE (ACT)

MANUFACTURER:

STYLE:

ACT-1 USG

MARS, 2'x2' TEGULAR

WHITE

9/16" WHITE CEILING GRID

RESILIENT TILE (RT)

MANUFACTURER:

STYLE:

COLOR:

RT-

FORBO

MCT

MCT-3048 GRAPHITE

SHERWIN WILLIAMS

NATURAL CHOICE SW7011

LOW VOC LATEX

EGGSHELL FINISH

MANUFACTURER:

STYLE:

COLOR:

SIZE:

QUARRY TILE (QT)

QT-1 DALTILE

QUARRY

ARID FLASH (2) 0Q48

6"x6"

MANUFACTURER:

STYLE:

COLOR:

SIZE:

CT-2 DALTILE

SANDALO

CASTILLIAN GRAY

6X6

FIRST FLOOR

0"

A.3

A101

A101

8.05

9.03

9.04

5.05

32.02 2.34

7.06

EXISTING

4.01A

EXISTING

4.04B

4.04A

7.35

W1

3.33

4'

0" 8"

2'

4"

1/2"

1/2"

3"

CMU BOND BEAM, RE: STRUCT.

6" METAL STUDS

HSS 6x6, RE: STRUCT.

5/8" GYP. BD.

WOOD SILL, PAINT

STEEL PLATE, RE: STRUCT.

ALUM. STOREFRONT SILL

SELF-ADHERED

FLEXIBLE

FLASHING

METAL FLASHING

SET IN SEALANT

BED

EXISTING BRICK

METAL FLASHING

SET IN SEALANT

BED

BACKER ROD AND SEALANT

8" CMU

PLYWOOD SHIM 1/2"

SEALANT

7 1/8"

8" CMU

CMU BOND

BEAM, RE:

STRUCT.

METAL FLASHING

SELF-ADHERED

FLEXIBLE

FLASHING

BACKER ROD

AND SEALANT

6" METAL STUDS

HSS 6x6, RE: STRUCT.

5/8" GYP. BD.

STEEL PLATE, RE: STRUCT.

BACKER ROD AND SEALANT

PLYWOOD SHIM

ALUM. STOREFRONT HEAD

GLAZING LEGEND - SEE SPECIFICATION 08 88 00

MARK

GL-1 1 5/16" TINTED INSULATED GLASS UNIT

GL-2

DESCRIPTION

FIRELITE GLASS

ABBREVIATIONS

ALUM -

FACTORY -

HM -

PNT -

SC -

ALUMINUM

FACTORY FINISH

HOLLOW METAL

PAINT

SOLID CORE (WOOD DOOR)

D1

FLUSH

D2

FULL

VISION

6" 6"

6" 1'

0"

D3

HALF

VISION

GL-2

6" 6"

6"

TO

G

LA

S S

3'

6"

VFY GLAZING

SIZE W/ MANUF.

FIRST FLOOR

0"

4'

0" 3'

0"

1/

2" 3'

7"

1/

2"

3' - 4"

2 1/2" 2' - 11" 2 1/2"

ALUM. STOREFRONT

BACKER ROD

AND SEALANT

5/8" GYP. BD.

STEEL PLATE,

RE: STRUCT.

PLYWOOD SHIM

BACKER ROD

AND SEALANT

CMU RE: STRUCT.

FURRING

HSS 6x6, RE: STRUCT.

5/8" GYP. BD.

1/ 2"

5'

0"

FINISHED FLOOR

CEILING

BULLNOSE EDGE

PNT-1 (SEMI-GLOSS)

CT-2

CHARLESTON

NO. 2676

GARY J. BOEHMST

AT

E OF SOUTH CAROLINA

REGISTERED A RCHITECT

G

E W

BAIR AS

I N62 8T H

IR

A D

MAN

COM

MO

IT Y

B I L

SEAL AREA

DA

TE

P R E P

B Y

A P P R 'D

RECORD DRAWING DATE

DRAWING SIZE:

PROJECT NO.

DE

PA

RT

M

EN

T

OF

T H E

AI

R

FO

RC

E

AI

R M

OB

IL

IT

Y C

OM

M

AN

D

R E V

D A

TE

D E S C R

IP

TI

O N

D R A W

IN

G

R E V

IS

IO

N S

CH

K B

Y:

DR

AW

N

BY

DS

GN

BY

SU

PV

CH

EN

GR

GL

IC

K/

BO

EH

M

AS

SO

CI

AT

ES

, IN

C

3 K

IN

G

ST

RE

ET

, S

UI

TE

CH

AR

LE

ST

ON

, S

C

JO

IN

T B A S E

C H A R

LE

S

TO

N

A B

C H A R

LE

S

TO

N S C

ARCH30 E(30X42)

OF 056SHEET

A101

FL

OO

R

PL

AN

S S

TO

RY

A

RE

A

De sig ne r

Au tho r Ch ec ke r

/27

/17

JB

C

AB

B

RE

PA

IR

A

IR

C

RA

FT

M

AI

NT

EN

AN

C E H

AN

GE

R

DKGV:DKFX 11-1171

KEYNOTE LEGEND

Key Value Keynote Text

2.32 EXISTING STEEL LADDER, TO REMAIN. PAINT.

2.34 EXISTING CONCRETE SLAB ON GRADE

2.37 EXISTING CONCRETE BOLLARD

2.39 EXISTING ICE MAKER

2.40 EXISTING DRINKING FOUNTAIN

2.43 EXISTING DOWNSPOUT

3.02 CONCRETE FOUNDATION, RE: STRUCT.

3.33 12" X 12" CONCRETE FOOTING AT NEW OPENING, RE:

STRUCT.

4.01A BRICK VENEER, EXISTING TO REMAIN.

4.04A 8" CMU, ABRADE AND PAINT

4.04B 8" CMU

5.02 STRUCTURAL STEEL COLUMN, RE: STRUCT., PAINT

5.05 STRUCTURAL STEEL STUD 6"

7.06 STANDING SEAM METAL ROOF.

7.35 EXPANSION JOINT MATERIAL, 1/2", RE: STRUCT.

8.05 ALUMINUM STOREFRONT

9.01 CARPET, CPT-1. PROVIDE BASE RB-1.

9.03 ACOUSTIC CEILING TILE

9.04 GYPSUM WALL BOARD

9.06 RESILIENT TILE FLOORING, RT-1. PROVIDE BASE RB-1.

9.31 ROUGH, NON-SKID FLOOR SURFACE: EF-1 WITH COVE

BASE.

9.33 CERAMIC TILE FLOORING AND WALLS. TILE ON WALLS TO

EXTEND TO UNDERSIDE OF CEILING. CT-1

9.34 INFILL AND PATCH WALL AT LOCATIONS OF DUCT

REMOVAL, RE: MECH. MATCH CONSTRUCTION AND FINISH

OF EXISTING WALL.

10.11 ADA SHOWER SEAT

10.30 TOWEL HOOK

10.31 SHOWER ROD AND CURTAIN

22.01 DRINKING FOUNTAIN, EXISTING TO REMAIN.

22.08 EYE WASH AND SHOWER, EXISTING TO REMAIN.

22.11 PRE-MANUFACTURED SHOWER STALL

22.11B FLOOR SLAB TO BE GROUND. DONE TO ALLOW 1" RECCESS.

INTENT IS FOR LIP ON SHOWER UNIT TO BE NO MORE THAN

1/2" A.F.F. ADD METAL FURRING STRIPS AROUND SHOWER

UNIT AS NECESSARY. COORDINATE WITH

MANUFACTURER'S INSTRUCTIONS.

23.01A HVAC UNIT, RE: MECH.

32.02 CEMENT CONCRETE PAVING, SLOPE AWAY FROM BUILDING

1% MIN, 2% MAX

SCALE: 1/8" = 1'-0"A100 A101

2 ENLARGED FIRST FLOOR PLAN - NORTH

SCALE: 1/8" = 1'-0"A100 A101

1 ENLARGED FIRST FLOOR PLAN - SOUTHSCALE: 3/4" = 1'-0"A101 A101

3 WALL SECTION

SCALE: 3" = 1'-0"A101 A101

5 WINDOW SILL DETAIL

SCALE: 3" = 1'-0"A101 A101

6 WINDOW HEAD DETAIL

NUMBER TYPE HEIGHT WIDTH (LEAF 1) THICKNESS MATERIAL FINISH GLAZING

FRAMES FIRE

RATING HARDWARE SET

DETAILS

NOTESTYPE MATERIAL FINISH HEAD JAMB SILL

03 D3 7' - 0" 3' - 0" 1 3/4" FRP BY MANUF. GL-2 EXIST EXIST PNT 45 MIN. 1 NEW FIRE DOOR IN EXISTING HM FRAME

SCALE: 1/4" = 1'-0"

DOOR TYPE ELEVATIONS

SCALE: 1/4" = 1'-0"

FRAME TYPE W1

HARDWARE SETS:

HW 1: 1 1/2 PAIR BUT HINGES A8112, 4.5x1.5 BHMA 626

1 LOCKSET (MORTISSE) SERIES 4000, GRADE 1, F21, BHMA 626

1 KICKPLATE

1 CLOSER C02022, SIZE IV, BHMA 626

1 SET SILENCERS

1 SWEEP

SCALE: 3" = 1'-0"A101 A101

4 WINDOW JAMB DETAIL

SCALE: 1/2" = 1'-0"

WFP1

AD

DE

ND

UM

7/

/2

Sheets
A100 - FIRST FLOOR PLAN
A101 - FLOOR PLANS - 1 STORY AREA

File details come from the government source that posted it. Updated .