Attachment 3 Repair Aircraft Maint Hanger Drawing Set.pdf
PDF 22 MB Posted
- Attached to
- Repair Maintenance Hanger, Bldg 700 Federal contract opportunity
- Solicitation number
- FA441821R0015
About this file
This document provides details on a federal solicitation to repair a maintenance hangar at an Air Force base. Solicitation number FA441821R0015 calls for bids to repair Building 700, as described in the attached drawings and specifications. The required work includes maintenance and repairs to ensure the hangar meets operational needs. The soliciting agency is the Department of the Air Force Air Mobility Command. Interested contractors should review all attachments for full details on the scope of work and submit bid responses in accordance with the instructions in the solicitation documents.
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G
E W
BAIR AS
I N62 8T H
IR
A D
M AN
COM
MO
IT Y
B I L
G
E W
BA IR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T H E
AI
R
FO
RC
E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N B
Y:
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
C H A R
LE
S
TO
N S C
ARCH E(30X42)
G000
C
OV
ER
S
HE
ET
De sig ne r
PJ
O
SM
7/1 0/2
JB
C
AB
B
RE
PA
IR
A
IR
C
RA
FT
M
AI
NT
EN
AN
C E H
AN
GE
R
DKFX 11-1171
DKFX 11-1171
REPAIR AIRCRAFT MAINTENANCE HANGAR B700
JOINT BASE CHARLESTON AIR BASE WING
CHARLESTON, SOUTH CAROLINA
100% SUBMITTAL
STRUCTURAL ENGINEER
ARCHITECT
ADC ENGINEERING
1226 YEAMANS HALL ROAD
HANAHAN, SOUTH CAROLINA 29410
843-566-0161
GLICK/BOEHM & ASSOCIATES
493 KING STREET, SUITE 100
CHARLESTONG, SC
843.577.6377
JULY 27, 2017
MECHANICAL/ELECTRICAL ENGINEER
DWG, INC.
1099 ANNA KNAPP BLVD, SUITE 202
MOUNT PLEASANT, SOUTH CAROLINA 29464
843-849-1141
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ACT ACOUSTICAL CEILING TILE
B/ BOTTOM OF
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BRG BEARING
CA CAST ACRYLIC
CI CONTINUOUS INSULATION
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CPT CARPET
DET DETAIL
DIAM DIAMETER
DIM DIMENSION
DN DOWN
DWG DRAWING
EA EACH
EJ EXPANSION JOINT
EL OR ELEV ELEVATION
EQ EQUAL
EQUIP EQUIPMENT
ET EPOXY TERRAZO
EW EACH WAY
EXIST EXISTING
EXP EXPOSED (TO STRUCTURE)
EXT EXTERIOR
FACT FACTORY FINISH
FD FLOOR DRAIN
FDN FOUNDATION
FEC FIRE EXTINGUISHER CABINET
FIN FINISH (ED)
FL OR FLR FLOOR
FOB FACE OF BRICK
FOF FACE OF FINISH
FOS FACE OF STUD
FT FOOT/FEET
G GROUT
GA GAGE, GAUGE
GALV GALVANIZED
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFRC GLASS FIBER REINFORCED
CONCRETE
GL GLASS, GLAZING
GWB GYPSUM WALLBOARD
GYP GYPSUM
HC HOLLOW CORE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
ID INSIDE DIAMETER
INSUL INSULATION
JT JOINT
LAV LAVATORY
LP LOW POINT
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MT METAL THRESHOLD
MTL METAL
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
NIC NOT IN CONTRACT
NO OR # NUMBER
N NORTH
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OPG OPENING
OPP OPPOSITE
PL PLASTIC LAMINATE
PNT PAINT
PT PRESSURE-TREATED
RAD RADIUS
RCP REFLECTED CEILING PLAN
REQ'D REQUIRED
R RISER
RD ROOF DRAIN
REINF REINFORCED
REV REVERSED
RO ROUGH OPENING
SC SOLID CORE
SF STOREFRONT
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
ST STAIN
STL STEEL
SV SHEET VINYL FLOORING
SUSP SUSPENDED
T/ TOP OF
T TREAD
TBB TILE BACKERBOARD
TEMP TEMPORARY
THK THICK
TP TOILET PARTITION
TYP TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VPAB VAPOR PERMEABLE
AIR BARRIER
VWC VINYL WALL COVERING
WD WOOD
W/ WITH
W/O WITHOUT
WT WALL TILE
ABBREVIATIONS
55 View Name
SCALE: 1/8" = 1'-0"
1 View Name
SCALE: 1/8" = 1'-0"A101
55 View Name
SCALE: 1/8" = 1'-0"A101 A101
View Name
SCALE: 1/8" = 1'-0"
TYPICAL SYMBOLS USED ON ALL
ARCHITECTURAL SHEETS
DETAIL TITLE WITHOUT DETAIL NUMBER: USED
ONLY FOR TYPICAL DETAILS THAT DO NOT
HAVE TO BE REFERENCED OR FOR "FLOOR"
TYPE PLANS.
1-PART DETAIL TITLE WITH DETAIL NUMBER:
USED TO IDENTIFY DETAILS THAT DO NOT HAVE
TO BE REFERENCED BACK TO DETAIL CUT.
2-PART DETAIL TITLE WITH DETAIL NUMBER &
REFERENCED SHEET NO.: USED TO IDENTIFY
DETAILS THAT NEED TO BE REFERENCED
BACK TO DETAIL CUT.
3-PART DETAIL TITLE WITH DETAIL NUMBER,
REFERENCE SHEET NO & ORIGINATION SHEET
NO.: USED TO IDENTIFY DETAILS THAT NEED TO
BE REFERENCED BOTH TO THE DETAIL CUT AS
WELL AS WHERE IT IS DRAWN.
A101
2-PART WALL SECTION CALLOUT KEY WITH
DETAIL NUMBER & SHEET REFERENCE WHERE
DETAIL IS DRAWN.
A101
3-PART WALL SECTION CALLOUT KEY WITH
DETAIL NUMBER, REFERENCE SHEET WHERE
DETAIL IS KEYED & SHEET REFERENCE WHERE
DETAIL IS DRAWN.
A101
A101
2-PART BUILDING SECTION CALLOUT KEY WITH
DETAIL NUMBER & SHEET REFERENCE WHERE
DETAIL IS DRAWN.
A101
3-PART BUILDING SECTION CALLOUT KEY WITH
DETAIL NUMBER, REFERENCE SHEET WHERE
DETAIL IS KEYED & SHEET REFERENCE WHERE
DETAIL IS DRAWN.
A101
A101
A101 A101
ELEVATION CALLOUT KEY WITH DETAIL NUMBER
& SHEET REFERENCE WHERE DETAIL IS DRAWN.
A101 A101
A101
2-PART ELEVATION CALLOUT KEY WITH DETAIL
NUMBER & SHEET REFERENCE WHERE DETAIL
IS DRAWN.
3-PART ELEVATION CALLOUT KEY WITH DETAIL
NUMBER, REFERENCE SHEET WHERE DETAIL IS
KEYED & SHEET REFERENCE WHERE DETAIL IS
DRAWN.
A101
0' 2' 4' 8' 16'
GRAPHIC SCALE OF A SHEET OR DETAIL
2 HOUR FIRE RATED WALL: SEE WALL TYPES
3 HOUR FIRE RATED WALL: SEE WALL TYPES
4 HOUR FIRE RATED WALL: SEE WALL TYPES
SMOKE RATED WALL: SEE WALL TYPES
Room name
101 ROOM NAME & NUMBER:
SEE SHEET A6xx FOR FINISHES
WALL TYPES: SEE SHEET A5xx FOR TYPES
REVISION MARK - ASI / RFI / PR / CCD
Name Elevation VERTICAL DATUM MARKER
KEYNOTE
COLUMN GRID MARK
CENTERLINE
DOOR MARK: SEE SHEET A6xx FOR
SCHEDULE, TYPES AND FRAME ELEVATIONS
WINDOW MARK: SEE SHEET A6xx FOR
SCHEDULE AND FRAME ELEVATIONS
CMU WALL: SEE WALL TYPES, SHT. A5xx
STUD WALL: SEE WALL TYPES, SHT. A5xx
EXISTING WALL TO REMAIN
DEMOLISHED WALL
1t
LEGEND & SYMBOLS
1i
1 HOUR FIRE RATED WALL: SEE WALL TYPES
0 EXISTING COLUMN GRID MARK
PROJ.
PLAN NORTH ARROW
DEMOLITION KEYNOTE
CEILING HEIGHT10'-0"
1 REVISION MARK - ADDENDA
ASI 01
EQUIPMENT TAG
ROOF SLOPE
1i
ROOF SLOPE - RISE / RUNX"
X"
X"/FT
TRUE
TRUE NORTH ARROW
GYP. BD -
SEE WALL TYPE
METAL STUDS -
SEE WALL TYPE
SOUND BATTS
WHERE INDICATED
SUSPENDED ACOUSTICAL
CEILING & GRID - SEE
REFLECTED CEILING PLAN &
SEISMIC SUPPORT DETAILS
TO BRACE WALL, EITHER
EXTEND STUDS STRAIGHT
UP TO DECK ABOVE OR
KICK OUT STUDS AT 45
DEGREES EACH SIDE 32" o.c.
STAGGERED
6"
METAL BAR JOIST -
SEE STRUCT. DWGS
FOR ACTUAL SIZE
GYP. BD -
SEE WALL TYPE
METAL STUDS -
SEE WALL TYPE
SOUND BATTS
WHERE INDICATED
SEAL WALL TO
DECK, TYP.
METAL DECK -
SEE STRUCT. DWGS
1' - 0"
MIN.
NOTE: WHEN SPACE BETWEEN STUD &
JOIST IS LESS THAN 12", CONSTRUCT
PER DETAIL OPTION "B" THIS SHEET.
METAL BAR JOIST -
SEE STRUCT. DWGS
FOR ACTUAL SIZE
1-5/8" METAL STUDS @
16" o.c. WRAP AROUND
JOIST
GYP. BD -
SEE WALL TYPE
METAL STUDS -
SEE WALL TYPE
METAL DECK -
SEE STRUCT. DWGS
SOUND BATTS
WHERE INDICATED
SEAL WALL TO
DECK, TYP.
NOTE: DETAIL SIMILAR AT STRUCTURAL STEEL MEMBERS
METAL BAR JOIST -
SEE STRUCT. DWGS
FOR ACTUAL SIZE
GYP. BD -
SEE WALL TYPE
METAL STUDS -
SEE WALL TYPE
METAL DECK -
SEE STRUCT. DWGS
SOUND BATTS
WHERE INDICATED
SEAL WALL TO
DECK & JOIST
PENETRATIONS,
TYP.
G
E W
BA IR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T H E
AI
R
FO
RC
E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N B
Y:
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
C H A R
LE
S
TO
N S C
ARCH E(30X42)
G001
GE
NE
RA
L
AR
C
HI
TE
C
TU
RA
L
IN
FO
RM
AT
IO
N
De sig ne r
Au tho r Ch ec ke r
/06
/12
JB
C
AB
B
RE
PA
IR
A
IR
C
RA
FT
M
AI
NT
EN
AN
C E H
AN
GE
R
DKFX 11-1171
SCALE: 1 1/2" = 1'-0"G001
1 T.O. WALL DETAIL - ABOVE CLG
SCALE: 1 1/2" = 1'-0"G001
2 WALL TO STRUCTURE DETAIL
SCALE: 1 1/2" = 1'-0"G001
3 WALL TO STRUCTURE DETAIL
SCALE: 1 1/2" = 1'-0"G001
4 WALL TO STRUCTURE DETAIL
SCALE (MILES)
CHARLESTON
FOLLY BEACH
ISLAND
JOHNS
SULLIVANS ISLAND
JAMES ISLAND
CHARLESTON
MT. PLEASANT
CHARLESTON
NORTH
AIR FORCE BASE
CHARLESTON
ATLA
NTIC
OCEA
N
CHARLESTON
HARBOR
SAVANNAH HWY
FO
LL
Y
RO
AD
ST
ON
O
RIV
ER
FT. JOHNSON ROAD
AS
HL
EY
17o701
CO
OP
ER
526p
BEES FERRY ROAD
o
CHARLESTON CO.
LANDFILL
AVIATION AVE.
52o
RI
VE
R
526p
AS
HL
EY
R
IV
ER
R
OA
D
DO
RC
HE
ST
ER
R
OA
D
26p
MONTAGUE AVE.
RIV
ER
CA
INH
OY
R
OA
D
MARK CLARK EXPY.
REMOUNT ROAD
RI
VE
RS
A
VE
ASHLEY PHOSPHATE ROAD
E
CHARLESTON
GEORGETOWN
NORTH CAROLINA
AT
LA
NT
IC
O
CE
AN
GEORGIA
SAVANNAH
ORANGEBURG
COLUMBIA
AUGUSTA
GREENVILLE
SPARTANBURG
FLORENCE
CHARLOTTE
MYRTLE
BEACH
WILMINGTON
BEAUFORT
SOUTH CAROLINA
SCALE (MILES)
20100 40 o p
20p p o 95p
85p 25o p85p 385 26p
77p o
701o p95 o21
BUILDING 700
PROJECT SITE
BUILDING 700
G
E W
BA IR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T H E
AI
R
FO
RC
E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N B
Y:
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
C H A R
LE
S
TO
N S C
ARCH E(30X42)
G100
PR
OJ
EC
T M
AP
S
AN
D
DR
AW
IN
G
IN
DE
X
De sig ne r
JG
AL
W
/03
/10
JB
C
AB
B
RE
PA
IR
A
IR
C
RA
FT
M
AI
NT
EN
AN
C E H
AN
GE
R
DKFX 11-1171
AIR BASE MAP
LOCATION MAP
DRAWING LIST
Sheet Count Sheet No. Sheet Title
GENERAL
1 G000 COVER SHEET
2 G001 GENERAL ARCHITECTURAL INFORMATION
3 G100 PROJECT MAPS AND DRAWING INDEX
4 G101 PROJECT AND CODE INFORMATION
STRUCTURAL
5 S000 GENERAL NOTES
6 S101 FOUNDATION PLAN
7 S102 PLATFORM FRAMING PLAN
8 S201 TYPICAL DETAILS
9 S221 TYPICAL STEEL DETAILS
10 S222 TYPICAL STEEL DETAILS
11 S231 TYPICAL CMU DETAILS
12 S241 ATFP DETAILS
ARCHITECTURAL
13 AE100 EXISTING FLOOR PLAN
14 AE130 EXISTING ROOF PLAN
15 AE200 EXISTING EXTERIOR ELEVATIONS
16 AE201 EXISTING EXTERIOR ELEVATIONS
17 AD100 DEMOLITION PLAN
18 AD120 DEMOLITION CEILING PLAN
19 AD130 DEMOLITION ROOF PLAN
20 AD200 DEMOLITION ELEVATIONS
21 AD201 DEMOLITION ELEVATIONS
22 A100 FIRST FLOOR PLAN
23 A101 FLOOR PLANS - 1 STORY AREA
24 A120 REFLECTED CEILING PLAN
25 A130 ROOF PLAN
26 A200 EXTERIOR ELEVATIONS
27 A201 EXTERIOR ELEVATIONS
28 A420 INTERIOR ELEVATIONS
29 A421 INTERIOR ELEVATIONS
30 A500 TYPICAL MOUNTING HEIGHT DETAILS
31 A560 CEILING DETAILS
PLUMBING
32 P001 PLUMBING NOTES & LEGENDS
33 P101 PLUMBING PLAN
MECHANICAL
34 M001 HVAC - NOTES & LEGENDS
35 M002 HVAC SCHEDULES
36 M003 HVAC DETAILS
37 M004 HVAC DETAILS
38 M051 HVAC DEMOLITION PLAN
39 M052 HVAC ENLARGED DEMO PLANS
40 M101 HVAC NEW WORK PLAN
41 M102 HVAC NEW WORK ENLARGED PLANS
42 M500 HVAC ISOMETRIC AND SECTION VIEWS
43 M501 HVAC ISOMETRIC AND SECTION VIEWS
ELECTRICAL
44 E001 ELECTRICAL NOTES & LEGENDS
45 E002 ELECTRICAL SCHEDULES & DETAILS
46 E003 ELECTRICAL DETAILS
47 E010 ELECTRICAL PANEL SCHEDULES
48 E051 POWER & SYSTEMS DEMO KEY PLAN
49 E052 POWER & SYSTEMS ENLARGED DEMO PLANS
50 E053 LIGHTING DEMO KEY PLAN
51 E054 LIGHTING ENLARGED DEMO PLANS
52 E101 POWER & SYSTEMS KEY PLAN
53 E102 POWER & SYSTEMS ENLARGED PLANS
54 E103 LIGHTING PLAN
55 E104 LIGHTING ENLARGED PLANS
56 E105 LIGHTING CALCULATIONS
FLOOD HAZARD INFORMATION
FLOOD HAZARD AREA: N/A
SOILS & SITE
SOILS INVESTIGATION: NO
SPECIAL INSPECTIONS ARE REQUIRED
SPECIAL INSPECTIONS ARE NOT REQUIRED
IF SPECIAL INSPECTIONS ARE REQUIRED, THE OWNER SHALL EMPLOY ONE OR MORE
SPECIAL INSPECTORS TO PROVIDE INSPECTION SERVICES DURING THE CONSTRUCTION
PHASE IN ACCORDANCE WITH CHAPTER 17 OF IBC 2006. SEE SPECIFICATION SECTION 01 45
33 FOR THE ACTUAL REQUIREMENTS OF WORK SUBJECT TO SPECIAL INSPECTIONS FOR THIS
PROJECT.
ARCHITECT
GLICK/BOEHM & ASSOCIATES, INC.
493 King Street, Suite 100 Charleston, South Carolina 29403 843.577.6377
MECHANICAL ENGINEER
STRUCTURAL ENGINEER
PLUMBING ENGINEER
ELECTRICAL ENGINEER
GENERAL PROJECT INFORMATION
DESIGN TEAM
ARCHITECT OF RECORD: Myles I Glick, SC Registration No. 1869
MECHANICAL ENGINEER OF RECORD:
PLUMBING ENGINEER OF RECORD:
ELECTRICAL ENGINEER OF RECORD:
FIRE PROTECTION ENGINEER OF RECORD:
BASIC PROJECT INFO
PROJECT NAME: REPAIR AIRCRAFT MAINTENANCE HANGAR B700
PROJECT ADDRESS: Joint Base Charleston Air Base Wing (JB CHS-ABW) Charleston, SC
NOTE: SCHEMATIC SUBMITTAL WAS MADE ON 10/14/2011 WHEN 2006 IBC CODE WAS IN
EFFECT.
1. 2015 INTERNATIONAL BUILDING CODE W/ SC MODIFICATIONS
2. 2015 INTERNATIONAL FIRE CODE W/ SC MODIFICATIONS
3. 2015 INTERNATIONAL MECHANICAL CODE
4. 2015 INTERNATIONAL PLUMBING CODE
5. 2015 INTERNATIONAL FUEL GAS CODE W/ SC MODIFICATIONS
6. 2009 INTERNATIONAL ENERGY CONSERVATION CODE
7. 2012 NATIONAL ELECTRIC CODE
8. CHARLESTON CITY ZONING ORDINANCE
9. 1992 AMERICANS WITH DISABILITY ACT
10. ICC/ANSI A117.1 ACCESSIBILE AND USEABLE BUILDINGS AND FACILITIES, LATEST ED.
11. SOUTH CAROLINA ELEVATOR CODE AND REGULATIONS, LATEST EDITION
12. SC ENERGY EFFICIENCY STANDARDS ACT
13. ASHRAE 90.1-2010, ENERGY EFFICIENT DESIGN OF NEW BUILDINGS EXCEPT LOW-RISE
RESIDENTIAL BUILDINGS
14. STATE FIRE MARSHAL REGULATIONS
SPECIAL INSPECTIONS
EROSION AND SEDIMENT REDUCTION /
STORMWATER MANAGEMENT
NOT REQUIRED - NO SITE WORK
NOTE: SEE SITE PLANS FOR DESIGNER'S CERTIFICATION.
LEADERSHIP THROUGH ENERGY AND
ENVIROMENTAL DESIGN (LEED)
NOT REQUIRED - LEED RATING WILL NOT BE PURSUED.
LEED RATING IS REQUIRED. RATING SHALL BE "SILVER" VERSION 3.0. REFER TO
SPECIFICATION SECTION 01 xx xx FOR THE ACTUAL SCOPE OF WORK.
PRIMARY CODES AND ORDINANCES USED:
PROJECT SCOPE
BUILDING 700 IS A FULLY SPRINKLERED, 89,000 SF AIRCRAFT MAINTENANCE FACILITY
BUILT IN 1970, HAVING AN ATTACHED 7,000 SF ONE STORY PORTION.
PROJECT SCOPE INCLUDES EXTERIOR CLEANING AND PAINTING, INTERIOR WALL AND
CEILING REPAIR AND PAINTING, HVAC/MECHANICAL REPAIR, AND LIGHTING
REPLACEMENT IN SELECTED AREAS. THE SCOPE ALSO INCLUDES THE
CONSTRUCTION OF A NEW EXTERIOR STEEL MECHANICAL PLATFORM.
PROJECT TO BE PHASED SO THAT EXTERIOR ROOF REPLACEMENT IS COMPLETED
BEFORE INTERIOR WORK IS BEGUN.
SITE IS IN ZONE X
DWG, INC.
ADC ENGINEERING
engineer, SC Registration No. xxxxxx engineer, SC Registration No. xxxxxx engineer, SC Registration No. xxxxxx engineer, SC Registration No. xxxxxx
DWG, INC.
DWG, INC.
1099 Anna Knapp Blvd, Suite 202 Mount Pleasant, SC 29464 843.849.1141
1226 Yeamans Hall Road Hanahan, SC 29410 843.566.0161
1099 Anna Knapp Blvd, Suite 202 Mount Pleasant, SC 29464 843.849.1141
1099 Anna Knapp Blvd, Suite 202 Mount Pleasant, SC 29464 843.849.1141
BASIC BUILDING CODE INFORMATION
CONSTRUCTION CLASSIFICATION Type (IBC 602)
OCCUPANCY GROUP (IBC 302)(Note IBC 506.4.1)
OCCUPANCY GROUP (IBC Table 503)
Does building require Incidental Use Area Separation?
(IBC 508.2.2)
Does building have Accessory Occupancy (ies)?
What percent of story is accessory occupancy?
SF(IBC 508.3.1)
Mixed Occupancy (IBC 508.3)
Non separated (IBC 508.3.2)
Separated (IBC 508.3.3)
(IBC506.4.1)
OTHER FIRE PROTECTION SYSTEMS, DEVICES or FEATURES
The existing building is fully-sprinklered.
Existing - unknown
S-1
S-1
N/A
N/A
BASIC BUILDING CODE INFORMATION
No Yes
No Yes
No Yes
No Yes
No Yes
B
EXIST.
EXIST.
EXIST.
EXIST.
FIRE RATED WALL
- SEE PLANS FOR
WALL TYPE
FIRE CAULK & BACKER ROD
w/ CASING BEAD, EA. SIDE
NON-FIRE RATED
WALL - SEE PLANS
FOR WALL TYPE
FIRE RATED WALL
INSTALLATION GUIDE
SCALE: 1-1/2" = 1'-0"
NOTE:
FRAME 1 HR WALLS BEFORE NON-RATED WALLS.
FRAME 2 HR WALLS BEFORE 1 HR WALLS.
FRAME 3 HR WALLS BEFORE 2 HR WALLS
FRAME 4 HR WALLS BEFORE 3 HR WALLS
FRAME FIRE RATED WALLS BEFORE SMOKE WALLS
FRAME SMOKE WALLS BEFORE NON-RATED WALLS
MAINTAIN MIN.
3/4" GAP FOR
GYP. BD
FIRE RATED WALL CONSTRUCTION NOTES:
SECURE ALL STUDS TO FLOOR SLAB AND STRUCTURE ABOVE.
PROVIDE FOR MOVEMENTOF STRUCTURE ABOVE WITH
ADJUSTABLEPARTITION HEAD FRAMING AS SPECIFIED IN SECTION 09 20
00.
SEAL ALL VOIDS IN FIRE RATED WALL CONSTRUCTION AS SPECIFIED IN
SECTION 07 94 00.
PERMANENTLY IDENTIFY ALL FIRE RATED WALLS, INCLUDING BUT NOT
LIMITED TO FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS BY
PROVIDING EITHER A PERMANENTLY FIXED SIGN OR STENCIL IN ALL
CONCEALED SPACES. SEE DETAIL BELOW.
SEE SHEET A___ FOR TYPICAL FIRE RATED DETAILS.
1.
2.
3.
4.
5.
1 HOUR FIRE AND SMOKE BARRIER
PROTECT ALL OPENINGS
FIRE RATED WALL SIGNAGE
NO SCALE
USE 2 FOR TWO HOUR RATED WALLS
USE 3 FOR THREE HOUR RATED WALLS, ETC.
SPACE MAXIMUM 12' o.c. ON WALL. .
3" HIGH LETTERS IN A
CONTRASTING COLOR
G
E W
BA IR AS
I N62 8T H
IR
A D
MAN
COM
MO
IT Y
B I L
SEAL AREA
OFSHEET
DA
TE
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
DE
PA
RT
M
EN
T
OF
T H E
AI
R
FO
RC
E
AI
R M
OB
IL
IT
Y C
OM
M
AN
D
R E V
D A
TE
D E S C R
IP
TI
O N
D R A W
IN
G
R E V
IS
IO
N S
CH
K B
Y:
DR
AW
N B
Y:
DS
GN
BY
SU
PV
CH
EN
GR
GL
IC
K/
BO
EH
M
AS
SO
CI
AT
ES
, IN
C
3 K
IN
G
ST
RE
ET
, S
UI
TE
CH
AR
LE
ST
ON
, S
C
JO
IN
T B A S E
C H A R
LE
S
TO
N
C H A R
LE
S
TO
N S C
ARCH E(30X42)
G101
PR
OJ
EC
T
AN
D C
OD
E
IN
FO
RM
AT
IO
N
De sig ne r
Au tho r Ch ec ke r
/02
/16
JB
C
AB
B
RE
PA
IR
A
IR
C
RA
FT
M
AI
NT
EN
AN
C E H
AN
GE
R
DKFX 11-1171
TCX TOP CHORD EXTENSION
E0S EDGE OF SLAB
OUT TO OUT
OUTSIDE DIAMETER
OUTSIDE FACE
ON CENTER
OPENING
PLATE
OPPOSITE
OPEN WEB
POWDER ACTUATED FASTENER
POUNDS PER LINEAL FOOT
RADIUS
REFERENCE
RIGHT
RADIUS POINT
ROOF TOP UNIT
REVISION
RETURN
REINFORCEMENT
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PRESSURE TREATED
PROJECTION
O/O
OPNG
OC
OF
OD
OPP
0W
PLF
PAF
PL
ADJ
AB
AHU
AFF
ALUM
BUILDING
ARCH
APPD
B/
BLDG
APPROX
ALT
APPROXIMATE
APPROVED
ALTERNATE
ALUMINUM
ADJACENT
BOTTOM OF
ARCHITECT
AIR HANDLING UNIT
ABOVE FINISHED FLOOR
ANCHOR BOLT
PT
PSF
PSI
REF
RAD
RP
REV
RET
RTU
RT
BOTTOM
BEARING
BETWEEN
BLOCK
BRG
BOT
BRDG
BTWN
BLK
CLEAR
COLUMN
CHAM
CIRC
C/C
CLR
COL
CMU
CJ
CANT
BRIDGING
CANTILEVER
CONTROL JOINT
CIRCULAR
CHAMFER
CONCRETE MASONRY UNITS
CENTER TO CENTER
BEAMBM
PROJ
REINF
SLAB BOLSTER
STEP FOOTING
SPECIFICATIONS
SCHEDULE
SECTION
SIMILAR
SLEEVE ANCHOR
STEEL
STAINLESS STEEL
STANDARD
STIFFENERS
SPACING,ES
SQUARE
SHORT SLOTTED HOLES
TOP OF
SYMMETRICAL
TOP AND BOTTOM
TIE BEAM
TIE COLUMN
TYPICAL
TUBE STEEL
TRANSVERSE
TEMPORARY
UNLESS NOTED OTHERWISE
SB
SA
SIM
SPEC
SF-
SECT
SSL
SQ
SP
STIFF
STL
STD
SS
CONST
CONN
CONC
CTRD
COORD
CONTR
CONT
DOUBLE
DEPTH
DETAIL
D
DBL
DIA
DIM
DIAG
DET
CONSTRUCTION
COORDINATE
CONTINUOUS
CONTRACTOR
CENTERED
DIMENSION
DIAGONAL
DIAMETER
CONNECTION
CONCRETE
SYMM
TC
T&B
TB
T/
TYP
TS
TRAN
UNO
TEMP
EACH
EAST
DWGS
EB
EF
EA
E
EQUAL
EL
ELEV
EMBED
EJ
EQ
ENGR
EQUIP
DRAWINGS
EXPANSION BOLT
EACH FACE
EMBEDMENT
EQUIPMENT
ELEVATOR
ENGINEER
ELEVATION
EXPANSION JOINT
DEAD LOADDL
SCHED
WEST
WITH
WITHOUT
VERTICAL
WEIGHT
WORK POINT
WELDED WIRE MESH
W
VERT
W/
W/O
WT
WWM
WP
EXISTING
EXP
EW
ES
EXT
EXIST
FINISH
FLOOR
FEET
FOOTING
FRAMING
FF
FLR
FIN
FTG
FRMG
FT
FDN
FC
EXTERIOR
EXPANSION
FILLED CELL
EACH WAY
FOUNDATION
FINISHED FLOOR
EACH SIDE
GAUGE
FV
GA
GALV
HORIZ
HEIGHT
INCH
HSB
HT
IF
IN
ID
HSA
HORIZONTAL
GALVANIZED
INSIDE DIAMETER
INSIDE FACE
HIGH STRENGTH BOLT
HEADED STUD ANCHOR
FIELD VERIFY
EQUIVALENTEQUIV
SOUTHS
INTERIOR
LONG
POUND
INCL
INT
LL
LG
LB
LIGHT
LLV
LLH
LONG
LTWT
LT
LSL
LLBB
INCLUDE, ING
LIVE LOAD
LIGHTWEIGHT
LONGITUDINAL
LONG LEG BACK TO BACK
LONG SLOTTED HOLES
LONG LEG VERTICAL
LONG LEG HORIZONTAL
MINIMUM
MIDDLE
MAX
MAS
MECH
MID
MIN
MFR
MEZZ
NOMINAL
NUMBER
NORTH
MJ
MISC
MO
NOM
NO
NIC
N
MANUFACTURER
MEZZANINE
MECHANICAL
MAXIMUM
MASONRY
MASONRY JOINT
MISCELLANEOUS
NOT IN CONTRACT
MASONRY OPENING
NTS
NS
NOT TO SCALE
NEAR SIDE
AESS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL
ABBREVIATIONS:
JOIST BEARING ELEVATIONJBE
DECK BEARING ELEVATIONDBE
1. FOUNDATION DESIGN VALUES:
ALLOWABLE BEARING CAPACITY 2000-PSF (FROM EXIST AS-BUILT
DWG'S)
2. GRAVITY LOAD DESIGN VALUES: IBC-2015 / ASCE 7-10 / IEBC-2015
LIVE LOADS:
GRATING 150-PSF
ROOF LIVE LOADS:
FLAT ROOF 30-PSF
GROUND SNOW LOADS:
SNOW 5-PSF
DEAD LOADS:
ACTUAL MATERIAL WEIGHTS PER ASCE 7-10, SEE
ARCHITECTURAL DRAWINGS FOR ROOF, WALL, AND FLOOR
CONSTRUCTION
3. SEISMIC DESIGN VALUES: IBC-2015 / ASCE 7-10 / IEBC-2015
Ss = 1.50 g S1 = 0.50 g Sds = 1.00 g Sd1 = 0.50 g
SITE CLASS: "D" (ASSUMED)
BUILDING RISK CATEGORY: "IV"
IMPORTANCE FACTOR: Ie = 1.5
SEISMIC DESIGN CATEGORY: "D"
ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE METHOD
SEISMIC FORCE RESISTING SYSTEM:
-ORDINARY REINFORCED MASONRY SHEAR WALLS
RESPONSE MODIFICATION FACTOR: R = 2
DEFLECTION AMPLIFICATION FACTOR: Cd = 1.75
SYSTEM OVERSTRENGTH FACTOR: OMEGA = 2.5
-ORDINARY STEEL CONCENTRICALLY BRACED FRAMES
RESPONSE MODIFICATION FACTOR: R = 3.25
DEFLECTION AMPLIFICATION FACTOR: Cd = 3.25
SYSTEM OVERSTRENGTH FACTOR: OMEGA = 2
ALLOWABLE INTERSTORY DRIFT: 0.02 Hsx
4. WIND LOAD DESIGN VALUES: IBC-2015 / ASCE 7-10 / IEBC -2015
V = 154 mph (3-sec gust)
BUILDING RISK CATEGORY: "IV"
IMPORTANCE FACTOR: I = 1.00
EXPOSURE CATEGORY: "C"
ENCLOSURE CLASSIFICATION: OPEN
WIND DIRECTIONALITY FACTOR: Kd = 0.85 TOPOGRAPHIC FACTOR: Kzt = 1.0 VELOCITY EXPOSURE COEFFICIENT: Kz = 0.85 VELOCITY PRESSURE (ULTIMATE): q(ult) = 43.87-PSF VELOCITY PRESSURE (ASD): q(asd) = 26.32-PSF
INTERNAL PRESSURE COEFFICIENT: GCpi = +/- 0.18
ALLOWABLE INTERSTORY DRIFT: 0.0025 Hsx
STRUCTURAL DESIGN CRITERIA GENERAL NOTES
1. STRUCTURAL DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ENTIRE SET OF PROJECT DRAWINGS, PROJECT
MANUAL, AND ALL SHOP DRAWING SUBMITTALS.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING AND COORDINATING DIMENSIONS, CLEARANCES AND ALL OTHER
COORDINATION ISSUES WITH OTHER TRADES.
3. IN CASE OF CONFLICT BETWEEN VARIOUS STRUCTURAL DRAWINGS, STRUCTURAL PLANS, OR STRUCTURAL DETAILS
THE MORE STRINGENT SHALL GOVERN. THE CONTRACTOR SHALL MAKE ALLOWANCE IN HIS BID FOR THE MORE COSTLY
CONDITION.
4. IN CASE OF CONFLICT BETWEEN DRAWINGS, DRAWING NOTES, AND SPECIFICATIONS THE MORE STRINGENT SHALL GOVERN. THE CONTRACTOR SHALL MAKE ALLOWANCE IN HIS BID FOR THE MORE COSTLY CONDITION.
5. WORK NOT INDICATED ON THE DRAWINGS, BUT REASONABLY IMPLIED TO BE SIMILAR TO THAT SHOWN AT
CORRESPONDING PLACES SHALL BE REPEATED.
6. ALL NOTES, DETAILS AND SECTIONS ARE INTENDED TO BE TYPICAL FOR THE GENERAL CONDITIONS INDICATED OR REFERENCED. ALL NOTES, DETAILS AND SECTIONS SHALL APPLY TO ANY SIMILAR SITUATION THROUGHOUT THE ENTIRE
PROJECT UNLESS A SEPARATE NOTE, DETAIL OR SECTION IS PROVIDED.
7. REVIEW ALL PROJECT DOCUMENTS PRIOR TO FABRICATION AND START OF CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE OWNER OR OWNER'S REPRESENTATIVE PRIOR TO PROCEEDING WITH WORK.
8. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROTECT EXISTING AND IN PLACE WORK OR UTILITIES DURING
CONSTRUCTION
9. COORDINATE STRUCTURAL DRAWINGS WITH OTHER CONTRACT DRAWINGS, SPECIFICATIONS, OR SHOP DRAWINGS
WHICH MAY AFFECT THE STRUCTURAL WORK.
10. USE OF REPRODUCED CONTRACT DRAWINGS IN PART OR WHOLE FOR THE PURPOSE OF SHOP DRAWING PREPARATION SHALL NOT RELIEVE THE CONTRACTOR OR SUBCONTRACTOR FROM THE REQUIREMENT TO ACCURATELY LAYOUT, COORDINATE, DETAIL, FABRICATE AND INSTALL A COMPLETE STRUCTURE.
11. ALL SUBMITTALS SHALL BE REVIEWED BY THE SUBCONTRACTOR AND CONTRACTOR FOR CONFORMANCE TO THE CONTRACT DOCUMENTS, FOR COMPLETENESS, AND TO RESPOND TO CONTRACTOR COORDINATION RELATED QUESTIONS PRIOR TO SUBMITTING FOR APPROVAL. ALL SHEETS SHALL BE STAMPED AND INITIALED BY THE CONTRACTOR INDICATING SUCH A REVIEW HAS BEEN COMPLETED PRIOR TO ISSUING SUBMITTAL FOR APPROVAL.
12. CONTRACTOR SHALL MAKE NO DEVIATIONS FROM THE CONTRACT DOCUMENTS WITHOUT WRITTEN APPROVAL.
13. ALL ELEVATIONS INDICATED IN STRUCTURAL DRAWINGS ARE IN REFERENCED TO A GROUND FLOOR FINISHED SLAB
ELEVATION OF 0'-0" UNLESS NOTED OTHERWISE. SEE CIVIL FOR GROUND FLOOR FINISHED SLAB ELEVATION.
14. ALL EXTERIOR COMPONENTS ARE SUBJECT TO COMPONENTS AND CLADDING LOADING AS DIRECTED BY THE IBC. IT IS
THE G.C. AND COMPONENT MANUFACTURER'S RESPONSIBILITY TO ENSURE ALL COMPONENTS HAVE BEEN DESIGNED AND/OR TESTED TO MEET THE COMPONENTS AND CLADDING LOADING SPECIFIC TO THIS SITE AS REQUIRED BY THE IBC.
STRUCTURAL STEEL FRAMING
1. ALL STRUCTURAL STEEL FRAMING SHALL CONFORM TO SPECIFICATION SECTION 051200-"STRUCTURAL STEEL
FRAMING".
2. ALL STRUCTURAL STEEL FRAMING AND ARCHITECTURALLY EXPOSED STRUCTURAL STEEL FRAMING SHALL
CONFORM TO SPECIFICATION SECTION 051200-"STRUCTURAL STEEL FRAMING".
3. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL CONFORM TO SPECIFICATION SECTION
051213-"ARCHITECTURALLY EXPOSED STRUCTURAL STEEL FRAMING".
4. ALL STRUCTURAL STEEL ERECTION SHALL COMPLY WITH AISC 360-10 AND AISC 303-10.
5. CUTS OR BURNING OF HOLES IN STRUCTURAL STEEL MEMBERS IN THE FIELD WILL NOT BE PERMITTED.
6. THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING OR GUYS TO PROVIDE LATERAL SUPPORT OF THE
STRUCTURAL STEEL UNTIL THE PERMANENT LATERAL FORCE RESISTING SYSTEM IS COMPLETED.
7. THE ERECTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE OWNER'S SPECIAL INSPECTOR FOR PRE-
INSTALLATION VERIFICATION OF SLIP CRITICAL BOLT TIGHTENING PROCEDURES.
8. FIELD TESTING AND INSPECTION OF STRUCTURAL STEEL MATERIALS AND STRUCTURAL STEEL INSTALLATION SHALL
BE COMPLETED BY AN INDEPENDENT TESTING AGENCY COMMISSIONED BY THE OWNER, AND SHALL BE IN
ACCORDANCE WITH THE SCHEDULE OF SPECIAL INSPECTIONS.
FIELD WELDING
1. ALL FIELD WELDING SHALL CONFORM TO SPECIFICATION SECTION 051200-"STRUCTURAL STEEL FRAMING" FOR
WELDING STRUCTURAL STEEL FRAMING
2. ALL FIELD WELDING SHALL CONFORM TO SPECIFICATION SECTION 052100-"STEEL JOIST FRAMING" FOR WELDING
STEEL JOIST FRAMING
3. ALL FIELD WELDING SHALL CONFORM TO SPECIFICATION SECTION 053100-"STEEL DECKING" FOR WELDING STEEL
DECKING
4. ALL FIELD WELDING SHALL CONFORM TO SPECIFICATION SECTION 054000-"COLD FORMED METAL FRAMING", 054100-"ENGINEERED COLD FORMED METAL FRAMING", AND 054400-"ENGINEERED COLD FORMED METAL TRUSSES"
FOR WELDING COLD FORMED MEMBERS
5. ALL FIELD WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1, "STRUCTURAL WELDING CODE-STEEL" AND AWS
D1.3, "STRUCTURAL WELDING CODE-SHEET STEEL", LATEST EDITIONS.
6. ALL FIELD WELDING SHALL BE IN STRICT ACCORDANCE WITH WRITTEN WELD PROCEDURE (WPS) FOR THE GIVEN
WELD CONDITION
7. REPAIR ALL DAMAGED GALVANIZING, PRIMER OR PAINT ONCE WELDING IS COMPLETE
8. ELECTRODES SHALL BE STORED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS.
9. ALL PERSONNEL COMPLETING FIELD WELDS SHALL BE CERTIFIED IN ACCORDANCE WITH AWS TO PERFORM THE
GIVEN WELD.
10. FIELD TESTING AND INSPECTION OF FIELD WELDING MATERIALS AND FIELD WELDING SHALL BE COMPLETED BY AN
INDEPENDENT TESTING AGENCY COMMISSIONED BY THE OWNER, AND SHALL BE IN ACCORDANCE WITH THE
SCHEDULE OF SPECIAL INSPECTIONS.
POST INSTALLED STRUCTURAL ANCHORS
1. ALL POST INSTALLED STRUCTURAL ANCHORS SHALL CONFORM TO SPECIFICATION SECTION 050520-"POST
INSTALLED STRUCTURAL ANCHORS"
2. NOTED EMBEDMENT DEPTHS ARE FROM FACE OF CMU OR FACE OF CONCRETE
3. ALL INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURER'S DATA AND THE ASSOCIATED ICC
REPORT.
4. ALL PERSONNEL INSTALLING ANCHORS SHALL HAVE ATTENDED INSTALLER TRAINING PER THE SPECIFICATIONS
5. FIELD TESTING AND INSPECTION OF POST INSTALLED ANCHOR MATERIALS AND POST INSTALLED ANCHOR
INSTALLATION SHALL BE COMPLETED BY AN INDEPENDENT TESTING AGENCY COMMISSIONED BY THE OWNER, AND
SHALL BE IN ACCORDANCE WITH THE SCHEDULE OF SPECIAL INSPECTIONS.
CONTRACTOR NOTES
1. ALL EXPOSED STRUCTURAL STEEL SHALL BE HOT DIP GALVANIZED, G90 FINISH. THIS SHALL ALSO
INCLUDE TUBES, CHANNELS, AND ANGLES. THE G.C. SHALL PROVIDE TOUCH-UP COATINGS AS
REQUIRED AT LOCATIONS OF SCRATCHES, WELDS, AND ANY OTHER DAMAGED OR UNCOATED AREAS
DUE TO A CONNECTION OR CONTACT WITH AN ALTERNATE METERIAL, ETC.
2. THE G.C. SHALL FIELD VERIFY ALL EXISTING FRAMING ELEVATIONS AND DIMENSIONS.
3. THE G.C. SHALL COORDINATE NEW EQUIPMENT LAYOUT WITH EXISTING STRUCTURE AND EXISTING
MECH'L EQUIPMENT.
4. THE G.C. SHALL COORDINATE HVAC EQUIPMENT LAYOUT AND ATTACHMENT TO NEW STEEL PRIOR TO
STEEL FABRICATION.
5. NEW STEEL LOCATIONS MAY BE ADJUSTED SLIGHTLY TO ACCOMMODATE NEW MEP EQUIPMENT
SUPPORT & ATTACHMENT LOCATION/REQUIREMENTS.
6. ALL ITEMS SHALL BE VERIFIED PRIOR TO NEW STEEL FABRICATION.
7. ALL FLASHING AND WATERPROOFING IS BY OTHERS, NOT APART OF ADC'S SCOPE OF WORK.
C E
R T
I F
IC
AT E
OF AUTHOR
I Z A
T I O
NENGINEERING
ADC
NO. 00253
INC.
S O
U
T H
C A R O L
I N
A
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D
AT
E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K
BY
D
R
AW
N B
Y:
D
SG
N
B Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
07/27/2017
S000
G
EN
ER
AL
N O
TE
S
A C
P A
C P
C
JG
/1
0/
JB
C
AB
B
R
EP
AI
R
AI
R C R
AF
T
M
AI
N
TE
N
AN
C E H
AN
G
ER
ADC #17005.0
WIND PRESSURE ZONES DIAGRAM
a = 3-FT
DRAWING LIST
SHEET
NUMBER SHEET NAME
S000 GENERAL NOTES
S101 FOUNDATION PLAN
S102 PLATFORM FRAMING PLAN
S201 TYPICAL FOUNDATION DETAILS
S221 TYPICAL STEEL DETAILS
S222 TYPICAL STEEL DETAILS
S231 TYPICAL CMU DETAILS
S241 ATFP DETAILS
No. 28196
S O
UTH CAROL INA
L
IC
E
N S
E D
P
R O
F E S S I O N A
L E
N G
I N
E E
R
C H
R
IS
TOPHER J .
G
I L G
E R
TYPICAL TOP OF FTG = -1'-4"
THE G.C. SHALL COOORD WITH TYPICAL DETAILS FOR ANY AND ALL ADDITIONAL
FRAMING REQUIREMENTS NOT SHOWN HEREIN.
= EXISTING FOUNDATIONS / BUILDING
• SF=STEP FOOTING, SEE TYPICAL DETAIL X/S-XXX
• CENTER ALL SPREAD FOOTINGS BENEATH COLUMNS/PIERS/PILASTERS
• ALL STRIP FOOTING REINFORCING SHALL BE CONTINUOUS THROUGH SPREAD
FOOTINGS
• PROVIDE CORNER BARS AT ALL STRIP FOOTING CHANGES IN DIRECTION
EXTEND STRIP FOOTINGS A MINIMUM OF 8" PAST END OF WALL AT FOOTING
TERMINATIONS
TYPICAL EXTERIOR SLAB ON GRADE CONSTRUCTION IS 4" SLAB W/ ONE LAYER
OF 6x6~W2.9xW2.9 WWR ON COMPACTED SUBGRADE. SEE SPECS FOR FINISH
REQUIREMENTS. SEE ARCH'LS AND CIVIL FOR ELEVARTIONS AND SLOPES.
FOUNDATION PLAN NOTES:
A
10.1 0.2 0.3
0.20.1
A.1
A.2
H
SS5X
5X 3/
H
SS5X
5X 3/
H
SS5X5X
3/8
H
SS5X5X
3/8
F66
F66 F66
EXIST BLDG
102102
105105
105105
EXISTING 1990's
STEEL FRAME &
REINFORCED CMU
BLDG BLDG
0.3
F66
102102
102102
107 107
T B
-1 .5
TB-1.5
TB-1.5
T B
-1 .5
.5
A.3
19'-6 1/4" +/- 4'-3"
/4
/8
/8
/8
EXIST F20 H
SS6X
6X 3/
H
SS6X
6X 3/
102114
EQ EQ EQ
E Q
E Q
S241
S241
28'-9 1/4" +/-
CJCJ
CJ
S201
S201
S201
S201
S201
117117
GB/TB SCHEDULE NOTES:
1. SEE TYPICAL DETAILS ON SXXX SERIES OF DRAWINGS FOR TREATMENT OF REINFORCING AT INTERSECTIONS WITH PILE CAPS, GB'S
OR TB'S.
2. SEE X/SXXX FOR SPLICING REQUIREMENTS.
3. ALL STIRRUPS SHALL BE CLOSED WITH SEISMIC BENDS.
4. MAINTAIN 4" CLEAR COVER AROUND ALL REINFORCING UNO.
5. ALL BARS SHALL BE SUPPORTED ON CHAIRS (PLASTIC OR HDG) WITH FLAT BASED TO PREVENT SINKING INTO SUBGRADE
6. LOCATE FIRST STIRRUP 4" OR LESS FROM FACE OF PILE CAP OR SUPPORTING GRADE/TIE BEAM UNO
7. ALL CONTINUOUS GRADE BEAMS (PRESENT BOTH SIDES OF PILE CAP, GB OR TB) SHALL HAVE TOP AND BOTTOM BARS
CONTINUOUS THROUGH INTERRUPTING PILE CAP, GB OR TB, SEE X/SXXX.
C E
R T
I F
IC
AT E
OF AUTHOR
I Z A
T I O
NENGINEERING
ADC
NO. 00253
INC.
S O
U
T H
C A R O L
I N
A
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D
AT
E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K
BY
D
R
AW
N B
Y:
D
SG
N
B Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
07/27/2017
S101
FO
U N D
AT
IO
N
P
LA
N
A C
P A
C P
C
JG
/1
0/
JB
C
R
EP
AI
R
AI
R C R
AF
T
M
AI
N
TE
N
AN
C E H
AN
G
ER
ADC #17005.0
KEYED NOTES (THIS SHEET ONLY)
102 REMOVE & REPLACE EXISTING ASPHALT PAVING AS NEEDED TO INSTALL NUEW COLUMNS AND FOUNDATIONS. PROVIDE NEW ASPHALT TO MATCH EXISTING ADJACENT ASPHALT.
COORDINATE WITH ARCH'LS AND CIVIL FOR SLOPES AND DRAINAGE REQUIREMENTS.
104 NEW LADDER, BOLT TO WALL, LADDER SHALL BE PER STEEL SUPPLIER / FABRICATOR, LADDER SHALL BEET ALL CURRENT OSHA AND IBC CODE REQUIREMENTS.
105 T/EXISTING SLAB = 0'-0"
106 PROVIDE PROTECTIVE/ RESTRICTIVE ACCESS TO LADDER (LOCKABLE LADDER COVER)
107 HSS 4x4x1/4" DIAGONAL BRACING BETWEEN COLUMNS. PROVIDE 1/2" GUSSET PL's (HDG).
109 HSS 6X6X3/8 HDR & SILL.
110 NEW 3000 PSI CONCRETE FTG 12"X12"X5'-0". SEE TYP DETAIL.
111 NEW TYPE B CMU INTEL OVER OPENING.
112 REINFORCE 2 ADJACENT CELL EACH SIDE OF OPENING.
113 NEW 8"CMU BOND BEAM SILL W/ 2-#4'S CONT., BELOW OPENING.
114 PROVIDE NEW 4" 3000-PSI (NW) CONCRETE SLAB WITH 6x6~W2.9xW2.9 WWF. PROVIDE CONTROL JOINTS @ 10'-0" O.C. EACH DIRECTION
115 SEE ARCH'LS FOR WINDOW SIZE AND LOCATION.
116 SEE MEP AND ARCH'LS DRWG'S FOR DUCT SIZE AND LOCATION.
117 THE G.C. SHALL BE RESPONSIBLE FOR FIELD LOCATING ALL UNDERGROUND UTILITIES AND INTERFERENCES PRIOR TO DIGGING FOUNDATIONS.
1/2" = 1'-0"1 FOUNDATION PLAN -AREA-B
GRADE BEAM/TIE BEAM SCHEDULE
TYPE WIDTH THICKNESS
TOP
REINFORCING
BOTTOM
REINFORCING STIRRUPS
TB-1.5 1'-6" 1'-0" (3)-#5'S (3)-#5'S #3'S @ 5" O.C.
SPREAD FOOTING SCHEDULE
FOOTING
TYPE LENGTH WIDTH THICKNESS BOTTOM REINFORCING TOP REINFORCING
CONTINUOUS FOOTING SCHEDULE
FOOTING TYPE WIDTH THICKNESS
LONGITUDINAL
REINFORCING
TRANSVERSE
REINFORCING
EXIST F15 1'-6" 1'-0" EXIST (2)-#5'S N/A
EXIST F20 2'-0" 1'-0" EXIST. (3)-#5'S N/A
No. 28196
S O
UTH CAROL INA
L
IC
E
N S
E D
P
R O
F E S S I O N A
L E
N G
I N
E E
R
C H
R
IS
TOPHER J .
G
I L G
E
DN
T
OS
OS
OS
OS
OS
T
T
T
T
TT
PROVIDE 1 1/4" OPEN METAL GRATING (HDG), NON-SERATED.
GRATING LOADING REQ'S = 150-PSF LL, 300-LB CONCENTRATED LOAD AT ANY POINT
HVAC UNIT SEISMIC AND VIBRATION ISOLATION BY OTHERS.
ALL EXPOSED STEEL SHALL BE HOT DIP GALVANIZED.
NOTE:
ADDITIONAL REINFORCING OF EXISTING WALL MAY BE REQ'D IF EXIST WALL REINF IS
DETERMINED TO BE INSUFFICIENT.
(F) = FLUSH
PLATFORM FRAMING PLAN NOTES:
A
10.1 0.2 0.3
0.20.1
A.1
A.2
0.3
W X
C
O N
T
W X
C
O N
T
/4
203203
EXISTING 1990's STEEL
FRAME &
REINFORCED CMU
BLDG BLDG
EXIST CMU
WALL BELOW
EXISTING 1970's
STEEL FRAME
HANGER
208208208
4'-3"19'-6 1/4"
/4
W14X22 (F)
W14X22 (F)
W14X22 (F)
W14X22 (F)
W X
F
W X
F
W X
F
W X
F
W X
F
W X
F
W X
F
W X
F
W X
F
W X
F
A.3
/8
/8
/8
EQ EQ
EQ EQ
5'-6" 9'-0 1/4" 5'-0"
S222
S222
S222
S222
S222
S221 max unit weight = 2500lbs
W10X12W10X12W10X12
W X
F
STEEL BEAM LEGEND
WXXxXX (+) C=XX" R=XX <XX>
BEAM SZE
BEAM CAMBER
FACTORED BEAM END SHEAR
(TYP. BOTH ENDS UNO)
(MIN. 25KIPS ALL BEAMS UNO)
CANTILEVER CONNECTION
CANTILEVER SECTION,
MATCH BEAM SIZE UNO.
MOMENT CONNECTION
FACTORED BEAM END AXIAL FORCE
(15+/- KIPS) (TYP. BOTH ENDS UNO)
INDICATES BEAM IS FLUSH WITH ADJACENT TOP OF JOIST/DBE
A
B
C
D
E
10.5 0.90.80.6 0.7
0.1 0.2 0.3
E X
IS
T
W A
L L W
B
R
IC
K V
E N
E E
R B
E L O
W
S221
S221
S222
111 113
111 113
S221
C E
R T
I F
IC
AT E
OF AUTHOR
I Z A
T I O
NENGINEERING
ADC
NO. 00253
INC.
S O
U
T H
C A R O L
I N
A
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D
AT
E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K
BY
D
R
AW
N B
Y:
D
SG
N
B Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
07/27/2017
S102
P
LA
TF
O R M
FR
AM
IN
G
P
LA
N
A C
P A
C P
C
JG
/1
0/
JB
C
R
EP
AI
R
AI
R C R
AF
T
M
AI
N
TE
N
AN
C E H
AN
G
ER
ADC #17005.0
KEYED NOTES (THIS SHEET ONLY)
111 NEW TYPE B CMU INTEL OVER OPENING.
112 REINFORCE 2 ADJACENT CELL EACH SIDE OF OPENING.
113 NEW 8"CMU BOND BEAM SILL W/ 2-#4'S CONT., BELOW OPENING.
202 GRATING SPAN.
203 HVAC UNIT, SEE MECH'L
205 1/2"Ø THRD'D ROD BRACING (HORIZONTAL). PROVIDE 3/8" TAB PL'S TO BOTTOM FLANGE OF BEAMS AND #2 CLEVIS'S FOR
ATTACHMENTS. ALL COMPONENTS SHALL BE (HDG).
206 NEW LADDER AND LOCKING ACCESS COVER PLATE, BY STEEL SUPPLIER / LADDER DESIGNER, TO MEET ALL CURRENT OSHA &
IBC CODE REQUIREMENTS.
207 PROVIDE FALL PROTECTION AT OPENING. FALL PROTECTION DESIGN, REQUIREMENTS, AND INSTALLATION BY OTHERS.
208 HANDRAIL POST LOCATION.
212 G.C. TO COORDINATE RAILING WITH MEP TO AVOID INTERFERENCE.
213 EXISTING CAGED LADDER TO REMAIN. G.C. TO ADJUST PLATFORM LOCATION AS NEEDER TO MAINTAIN CLEARANCE
REQUIREMENTS FOR EXISTING CAGED LADDER
214 COORDINATE DIMENSION WITH FINAL APPROVED HVAC EQUIPMENT SUPPORT REQUIREMENTS. G.C. SHALL COORDINATE WITH
STEEL FABRICATOR.
215 G.C. TO FIELD VERIFY CLEARANCE IS ACCEPTABLE.
301 UNISTRUT FRAME FOR DUCT SUPPORT BY OTHERS.
302 SEE MEP & ARCH'LS FOR DUCT LOCATION.
1/2" = 1'-0"1
PLATFORM FRAMING PLAN - AREA-B
T/ STEEL = 12'-0" AFF
1/8" = 1'-0"
STEEL BEAM LEGEND
No. 28196
S O
UTH CAROL INA
L
IC
E
N S
E D
P
R O
F E S S I O N A
L E
N G
I N
E E
R
C H
R
IS
TOPHER J .
G
I L G
E R
1/8" = 1'-0"3 HVAC DUCTWORK FRAMING PLAN
3"
NOTES:
1. DO NOT LOCATE CONSTRUCTION JOINTS IN COLUMN FOOTINGS OR ENLARGED SECTIONS
OF CONTINUOUS STRIP FOOTINGS.
2. EXTEND REINFORCING FROM FIRST POUR THRU BULKHEAD ADEQUATE DISTANCE TO
ENSURE A CLASS "B" SPLICE WITH REINFORCING FOR SECOND POUR.
2'-6 1/4"
CLASS "B" SPLICE
SEE GENERAL NOTES
KEY JOINT FULL WIDTH OF FOOTING,
PROVIDE ONE KEY PER 12" OF
FOOTING THICKNESS
(1)-#5x36" SHEAR DOWEL
PER 12" OF FOOTING WIDTH,
TYP. TOP AND BOTTOM
CONT. FOOTING REINFORCEMENT,
SEE SCHEDULES AND SECTIONS
3"
NOTES:
1. EXTEND REINFORCING FROM FIRST POUR THRU BULKHEAD ADEQUATE DISTANCE
TO ENSURE A CLASS "B" SPLICE WITH REINFORCING FOR SECOND POUR
2. BULKHEAD FOR FIRST POUR SHALL BE REMOVED AFTER INITIAL SET AND CONCRETE
ROUGHENED TO A MINIMUM 1/4" AMPLITUDE
3. LOCATE GRADE BEAM COLD JOINTS AT THIRD POINTS BETWEEN PILE CAPS AND/OR
SUPPORTING GRADE BEAMS
4. DO NOT LOCATED COLD JOINTS WITHIN REGIONS OF TOP OR BOTTOM BAR SPLICES
5. G.C. SHALL COORDINATE LOCATION OF CONSTRUCTION JOINTS WITH REBAR
DETAILER TO ENSURE PROPER TOP AND BOTTOM BAR SPLICING, AND PROPER
NUMBER OF JOINT DOWEL BARS.
2'-1 3/8"
CLASS "B" SPLICE
SEE GENERAL NOTES
KEY JOINT FULL WIDTH OF
GRADE/TIE BEAM
(2)-#9 x 9'-0" SHEAR DOWELS, TYP. TOP AND BOTTOM
TOP BARS, SEE SCHEDULE
SECOND
POUR
FIRST
POUR
BOTTOM BARS,
SEE SCHEDULE
EQ EQ
M
IN
COL.
CL
SEE PLAN
8"
C L R
T
Y P
3" CLR.
TYP.
ADJACENT GRADE
V A
R
IE
S
M
IN
NOTE:
SLAB SLOPES,
SEE PLAN.
4" SLAB W/ 3000 PSI CONC.
(NORMAL WEIGHT), SEE
PLAN ALSO.
FORM WIRE MESH
DOWN
INTO FOOTING.
3/4" CHAMFER EDGE.
#4 CONT. NOSE BAR.
(2)-#5's CONT.
3000 PSI CONCRETE FOOTING.
SHEAR REINFORCING/
STIRRUPS, SEE SCHEDULE
FOR SIZE & SPACING.
CONT. TOP REINFORCING,
SEE SCHEDULE FOR SIZE
& QUANTITY.
TYPICAL TB1 & F30 FOOTING
SECTION DETAIL
SEE SCHEDULE FOR
SIZE & REINFORCING
S E
E S
C H
E D
CONT. BOTTOM REINFORCING,
SEE SCHEDULE FOR SIZE &
QUANTITY.
A L L
S
ID
E S
C L R
T
Y P
135° HOOK
SHEAR REINF. STIRRUPS @
EA. INTERIOR BAR
NOTES:
1) PROVIDE STEP FOOTINGS AT ALL LOCATIONS INDICATED ON PLAN
2) PROVIDE STEP FOOTINGS AS REQUIRED TO AVOID PIPING AND OTHER MISC. MECHANICAL ITEMS
3) DO NOT STEP GRADE BEAM OR TIE BEAM FOOTING WITHOUT PRIOR APPROVAL FROM ENGINEER
18"
36"
#4 BENT NOSE BARS @ 6" O.C.
S E
E P
L A
N
M
A X
U
.N .O
TIE BARS, MATCH SIZE AND QUANTITY
OF MAIN FOOTING BARS
CLASS "B" SPLICE
SEE GENERAL
NOTES
CLASS "B" SPLICE
SEE GENERAL
NOTES
MAIN FOOTING BARS,
SEE FOOTING
SCHEDULE
18"W.x12"D.xLENGTH
3000 PSI CONC.
1/4" BENT PLATE W/ 1-5/8Øx6"
EMBEDMENT ANCHOR BOLT.
NEW SLAB
3/16
NEW STEEL LADDER, THE
LADDER SHALL BE
DESIGNED BY THE STEEL
SUPPLIER, AND SHALL
MEET ALL IBC AND OSHA
REQUIREMENTS.
1_
1/2" EXPANSION JOINT 1/2" EXPANSION JOINT
NEW SLAB
EDGE OF COLLAR, TYP.
M
IN
S E
E P
L A
N
M
IN
EDGE OF SLAB/ FACE OF BLOCK
STEP COLLAR INTO BRICK
SPACE BELOW GRADE AS
REQUIRED TO PROVIDE 3"
COVER ON BASE PLATE
BASE PLATE AND ANCHOR
BOLTS, SEE SPECIFIC DETAILS
COLUMN, SEE PLAN AND
SCHEDULE FOR SIZE
NOTES:
1. TOP OF COLLAR SHALL MATCH TOP OF ADJACENT SLAB. COORDINATE WITH UPFIT SLAB REQUIREMENTS
2. PROVIDE #3 TIES (2-PIECE "U" SHAPED) @ 8" O.C. VERTICALLY IN COLLAR. MIN. NUMBER OF TIES SHALL BE (2)
3. STEP COLLAR INTO BRICK SPACE BELOW GRADE AS REQUIRED TO PROVIDE MINIMUM COVER
4. COAT COLUMN, BASE PLATE, AND ANCHOR RODS WITH ASPHALT PAINT PRIOR TO POURING CONCRETE COLLAR.
5. DETAIL IS TYPICAL AT SLAB ON GRADE ONLY
6. COORDINATE COLLAR GEOMETRY WITH SPECIFIC PLAN DETAILS
3" MIN.3" MIN.
1'-6" Ø
6"
ROUNDED CONC.
TOP 1/2" CROWN
NOTE: BOLLARDS SHALL BE AS
REQUIRED BY OSHA
REGULATIONS. G.C. TO COORD.
6"Ø CONC. FILLED STEEL PIPE
PAINT SAFETY YELLOW
1" CROWN
PAVING
GRANULAR FILL
STEEL PIPE SLEEVE
CONCRETE FOOTING
10x10x1/4" THICK
PLATE WELDED
ALL AROUND
NOTE: SEE ARCHITECTURAL
DRAWINGS FOR LOCATION
EXISTING SLAB NEW SLAB/FOOTING
6" 1'-0" UNO
NEW #4x1'-6" LONG DOWELS
@ 24" O.C. (DRILL & EPOXY
INTO EXISTING SLAB)
SLAB ON GRADE,
SEE PLAN
VAPOR RETARDER
CAPILLARY BARRIER
AS INDICATED EXISTING FILL, RECOMPACTED PRIOR
TO POURING NEW SLAB/FOOTING
SLAB EDGES
#4x5'-0" RE-ENTRANT BAR
CONTROL JOINT, COORDINATE WITH
PLANS AND FINAL FIELD LAYOUT OF
CONTROL JOINTS
2"
2' -6
2' -6
FIRST POUR SECOND POUR
1'-0" 1'-0"
1/2"øx24" SMOOTH BARS @
24" O.C. (GREASE ONE END)
SLAB ON GRADE,
SEE PLAN
VAPOR RETARDER
CAPILLARY BARRIER
AS INDICATED COMPACTED SUBGRADE
PLATE, THROUGH
CENTERLINE OF TUBE STEEL
4" SLAB W/ WWM
ON COMPACTED FILL
SLIP CRITICAL CONNECTIONS DO NOT HDG,
GALVANIZE IN FIELD AFTER CONNECTION IS
FINAL. TYPICAL ALL CONNECTIONS SHOWN
HEREIN. DESIGN WELDED CONNECTIONS TO BE IN
ACCORDANCE WITH ALL CURRENT CODE
REQUIREMENTS, SEISMIC PROVISIONS AND ALL
SUBSEQUENT ADDENDUM'S TO THE CODE AND
SEISMIC PROVISIONS.
SEE TYPICAL DETAIL FOR BASE
PLATE ATTACHMENT
2" GROUT, TYPICAL
SEE PLAN FOR
COLUMN SIZE
3000-PSI CONC. COLLAR AROUND
COLUMNS, TYP.
TYP ALL
1'-0" M
IN
S E
E P
L A
N
S C
H E
D
T Y
P
S E
E P
L A
N
SEE PLAN/SCHED. FOR FTG. SIZE & REINF. REQUIREMENTS
1/2" EXPANSION JOINT MATERIAL
#4 DOWELS
C E
R T
I F
IC
AT E
OF AUTHOR
I Z A
T I O
NENGINEERING
ADC
NO. 00253
INC.
S O
U
T H
C A R O L
I N
A
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D
AT
E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K
BY
D
R
AW
N B
Y:
D
SG
N
B Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
07/27/2017
S201
TY
P
IC
AL
FO
U N D
AT
IO
N
D
ET
AI
LS
A C
P A
C P
C
JG
/1
0/
JB
C
R
EP
AI
R
AI
R C R
AF
T
M
AI
N
TE
N
AN
C E H
AN
G
ER
ADC #17005.0
1" = 1'-0"1
TYP. FOOTING CONSTRUCTION
JOINT
1" = 1'-0"2 TYP. GB/TB SPLICE
1" = 1'-0"4 TYP. THICKENED SLAB EDGE
1" = 1'-0"3 TYP. GB/ TB FOOTING SECTION
1" = 1'-0"6 TYP. STEP FOOTING (AS NEEDED)
1" = 1'-0"12 TYP LADDER BASE DETAIL
1" = 1'-0"5
TYP. STEEL COLUMN COLLAR
(PERIMETER CONDITION)
1" = 1'-0"8 TYP. BOLLARD DETAIL
1" = 1'-0"9A
TYP. NEW-TO-EXISTING SLAB
CONSTRUCTION
1" = 1'-0"10 TYP. SLAB RE-ENTRANT CORNER
1" = 1'-0"9B
TYP. SLAB-ON-GRADE
CONSTRUCTION JOINT
1" = 1'-0"11 TYP. FOUNDATION DETAIL
No. 28196
S O
UTH CAROL INA
L
IC
E
N S
E D
P
R O
F E S S I O N A
L E
N G
I N
E E
R
C H
R
IS
TOPHER J .
G
I L G
E
1" BASE
PLATE.
(4)-1" DIA. A325
(GRADE 55)
ANCHOR BOLTS.
2" 5" 5" 2"
1' - 2"
HSS COL.
5/16
2" TYP.
NON-SHRINK
GROUT.
@ HSS COLUMN
1" BASE PLATE.
(6)-1"Ø F1554 (GRADE
55, WELDABLE) ANCHOR
BOLTS.
NON-SHRINK
GROUT.
COL
CL
COL
CL
2" 6" 9" 2"
1' - 7"
1/8"x3"x3" PLATE WASHER
(W/ STANDARD HOLE).
1½"Ø GROUT HOLES.
1/4
5/16
3/8
COL TO BASE PL
BOTTOM OF GRADE BEAM.
1/2" THICK
GUSSET PLATE.
HSS COL.
3/8
HSS 6x6 COL.
5/16
5/16
1"Ø ANCHOR BOLTS.
PLATE, THROUGH CENTERLINE
OF TUBE STEEL
SLIP CRITICAL CONNECTIONS DO NOT GALVANIZE, GALVANIZE IN FIELD AFTER
CONNECTION IS FINAL. TYPICAL ALL CONNECTIONS SHOWN HEREIN. DESIGN
WELDED CONNECTIONS TO BE IN ACCORDANCE WITH ALL CURRENT CODE
REQUIREMENTS, SEISMIC PROVISIONS AND ALL SUBSEQUENT ADDENDUM'S TO
THE CODE AND SEISMIC PROVISIONS.
SLIP CRITICAL CONNECTION DO NOT SHOP
PRIME, PRIME IN FIELD AFTER CONNECTION
IS FINAL. TYPICAL ALL CONNECTIONS
SHOWN HEREIN.
SEE PLAN FOR
COLUMN SIZE
COLUMN CAP (1/4")
TYP ALL
1'-0" M
IN.
SLIP CRITICAL CONNECTIONS DO NOT GALVANIZE,
GALVANIZE IN FIELD AFTER CONNECTION IS FINAL.
TYPICAL ALL CONNECTIONS SHOWN HEREIN.
DESIGN WELDED CONNECTIONS TO BE IN
ACCORDANCE WITH ALL CURRENT CODE
REQUIREMENTS, SEISMIC PROVISIONS AND ALL
SUBSEQUENTS ADDENDUMNS TO THE CODE AND
SEISMIC PROVISIONS.
BEAM, SEE PLAN
C O
L U
M N
S
E E
P L A
N
C O
L U
M N
S
E E
P L A
N
SEE PLAN
SEE PLAN
SEE
TYP
SEE
TYP
SEE PLAN
NEW LINTEL
NEW L4 x 4 x 1/4
EXISTING 4" SPLIT FACE CMU
EXISTING 8" CMU
EXISTING K-SERIES BAR JOIST
NEW 8" CMU BOND BEAM
CONTINUOUS TO ADJACENT
CMU ON EACH SIDE
METAL STUD FURRING
REMOVE AND REPLACE
EXISTING END CLOSURE
EXISTING METAL DECK
EXISTING #5 CONT.
NEW DUCT,
SEE MEP
1/2"Ø THREADED ROD @ 10'-0"
MAX PER UNISTRUT DESIGNER
EXISTING W-BEAM
EXISTING HSS
EXISTING W-COLUMN
EXISTING W-GIRT
EXISTING WT-BEAM
A1001 UNISTRUT @ 10' O.C.
EXISTING METAL FRAMED WALLS
EXISTING CMU WALL
EXISTING BAR JOISTS
NEW HVAC DUCTWORK,
SEE MEP FOR DESIGN AND ATTACHMENTS
EXISTING METAL ROOF DECK
GIRT C/L
EL= 13'-6"
GIRT C/L
EL= 19'-6"
NEW L2 LINTEL
NEW DUCT,
SEE MEP
NEW CMU SILL
REINFORCE 2 ADJACENT CELLS EA SIDE
EXISTING CMU BOND BEAM W/ ANCHOR BOLT
EXISTING W-GIRT
EXISTING METAL SIDING
HVAC DUCTWORK, SEE MEP PLANS
ATTACHMENTS PER DUCT SUPPLIER/DESIGNER
1/2"Ø THREADED ROD @ 10'-0"
MAX PER UNISTRUT DESIGNER
EXISTING WT-BEAM,
CONNECTION PER
UNISTRUT DESIGNER
EXISTING HSS
UNISTRUT & ATTACHMENTS
BY OTHERS
EXISTING CMU WALL
EXISTING METAL DECK
EXISTING RAFTER BEAM
GIRT C/L
EL= 13'-6"+/-
GIRT C/L
EL= 8'-0"
GIRT C/L
EL= 19'-6"+/-
UNISTRUT ATTACHMENT BY
UNISTRUT SUPPLIER/DESIGNER
EXISTING COLUMN BRACE
NEW DUCT,
SEE MEP
NEW TYPE L2 LINTEL
NEW CMU SILL
REINFORCE 2 ADJACENT CELLS EACH SIDE
C E
R T
I F
IC
AT E
OF AUTHOR
I Z A
T I O
NENGINEERING
ADC
NO. 00253
INC.
S O
U
T H
C A R O L
I N
A
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D
AT
E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K
BY
D
R
AW
N B
Y:
D
SG
N
B Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
07/27/2017
S221
TY
P
IC
AL
S
TE
EL
D
ET
AI
LS
A C
P A
C P
C
JG
/1
0/
JB
C
R
EP
AI
R
AI
R C R
AF
T
M
AI
N
TE
N
AN
C E H
AN
G
ER
ADC #17005.0
3/4" = 1'-0"2 BP - TYP. BASE PLATE DETAIL (@ HSS COL.)
1" = 1'-0"3
TYP. BRACED FRAME HSS BASE
PLATE DETAIL
1" = 1'-0"4
STL - TYP. BRACED FRAME
(CONNECTION PER STEEL SUPPLIER)
1" = 1'-0"11
STL - TYP. ELEVATION OF BRACED
FRAME
No. 28196
S O
UTH CAROL INA
L
IC
E
N S
E D
P
R O
F E S S I O N A
L E
N G
I N
E E
R
C H
R
IS
TOPHER J .
G
I L G
E R
1" = 1'-0"1 SECTION
1/2" = 1'-0"5 SECTION
1/2" = 1'-0"7 SECTION
3/16
W-SECTION BEAM,
PER PLAN.
11/2"Ø PIPE RAILING @
12" O.C. (VERT.)
11/2"Ø POST COORD.
LOCATION W/ PLAN.
STEEL
GRATING,
SEE PLAN.
M A
X
M
IN
NOTE:
AT GRATING LOCATIONS SEE
GRATING MANUFACTURERS
REQUIREMENTS FOR GRATING
CONNECTION.
BEAM, PER PLAN.
1/4" TAB PLATE.
DBL L2x2x1/4
1/4" TAB PLATE.
1/4'x6" TOE PL (HDG), CONT
NOTE: SEE ALSO 9/S222
PROVIDE 1" SQUARE OPENING @
12" FROM BOTTOM OF PLATE FOR
WATER TO DRAIN
STEEL
GRATING,
SEE PLAN.
M
IN
NOTE:
AT GRATING LOCATIONS SEE GRATING
MANUFACTURERS REQUIREMENTS FOR
GRATING CONNECTION.
SHEAR CONX PER TYP.
DETAIL.
BEAM, PER PLAN.
M
IN
"Ø PIPE RAILING @
21" O.C. (VERT.) MAX.
11/2"Ø POST COORD.
LOCATION W/ PLAN.
11/2
1/4'x6" TOE PL (HDG), CONT
PROVIDE 1" SQUARE OPENING @
12" FROM BOTTOM OF PLATE FOR
WATER TO DRAIN
NOTE: SEE ALSO 9/S222
STEEL
GRATING,
SEE PLAN.
7" MIN
CLR.
1/4" TAB PL'S
LADDER, PER LADDER
SUPPIER/
STEEL FABRICATOR,
LADDER TO
MEET OSHA
REQUIREMENTS. FOR
FIXED LADDERS
ATTACHING TO A
PLATFORM
3/4"Ø RUNG, MIN. TYP.
NOTE:
AT GRATING LOCATIONS SEE GRATING
MANUFACTURERS REQUIREMENTS FOR
GRATING CONNECTION.
SHEAR CONX PER TYP.
DETAIL.
BEAM, PER PLAN.
BEAM, PER PLAN.
M
IN
"Ø PIPE RAILING @
12" O.C. (VERT.)
11/2"Ø POST COORD.
LOCATION W/ PLAN.
11/2
NOTE: SEE ALSO 9/S222
A-A
(PLAN VIEW)
1/2" TAB PLATE
COL
CL
A A
NOTE:
SEE PLAN FOR TOP OF
STEEL ELEVATION.
NOTE:
SOME FRAMING
OMITTED FOR CLARITY.
BEAM, SEE PLAN.
SHEAR CONX, PER
TYP. DETAIL.
DROPPED BEAM,
SEE PLAN.
SEE PLAN FOR PIN, THRD'D
ROD, & CLEVIS SIZE.
NOTE:
AT SIMILAR CONDITION,
HORIZONTAL BRACE IS ON
ONLY ONE SIDE.
RODS SHOWN
SCEWED
FOR CLARITY.
SEE PLAN FOR PIN,
THRD'D ROD, &
CLEVIS SIZE.
DROPPED BEAM,
SEE PLAN.
BEAM, SEE PLAN.
SHEAR CONX, PER
TYP. DETAIL.
SEE PLAN FOR PIN,
THRD'D ROD, &
CLEVIS SIZE.
SEE PLAN FOR PIN,
THRD'D ROD, &
CLEVIS SIZE.
CLEVIS FOR THRD'D ROD
BRACING CONNECTS TO TOP
FLANGE OF DROPPED BEAM.
STUB COL. BEYOND,
SEE PLAN.
TYP. BEAM TO HSS COL. CONX DETAIL
1/4
3/8" TAB PL
NOTCH THRU
COL.
BEAM, PER
PLAN.
BOLTS.
1/2" CAP PLATE.
STUB COLUMN,
SEE PLAN FOR
SIZE.
NOTE:
SEE PLAN FOR TOP
OF STEEL ELEVATION.
NOTE:
SOME FRAMING
OMITTED FOR CLARITY.
MAX 3/4"Ø A325
TYP. FLUSHED BEAM TO BEAM CONX
BEAM, PER
PLAN.
DBL L3x3x1/4 SHEAR
CONX W/ MAX 3/4"Ø
A325 BOLTS EA LEG
C-C
D
D
C
C
D-D
BEAM, PER
PLAN.
NOTE:
AT SIMILAR CONDITION,
BEAMS MAY FRAME INTO
BOTH SIDES.
NOTE:
SOME FRAMING
OMITTED FOR CLARITY.
NOTE:
SEE PLAN FOR TOP
OF STEEL ELEVATION.
M
IN
BEAM, SEE PLAN
1/4'x6" TOE PL (HDG), CONT
1/4"x6" TOE PL (HDG), CONT
PROVIDE 1" SQ WEEP
HOLES @ 12" O.C.
1/4"
3/16 4-12
STEEL GRATING,
SEE PLAN.
NOTE:
AT GRATING LOCATIONS SEE GRATING
MANUFACTURERS REQUIREMENTS FOR
GRATING CONNECTION.
NOTE:
SEE PLAN FOR TOP
OF STEEL ELEVATION.
NOTE:
AT SOME LOCATIONS 1 1/2"Ø
MAY BE AN HSS COL
1/2"Ø PIPE RAILING
@ 21" MAX SPACING
1 1/2"Ø POST (SPACING AS NEEDED
BY DESIGN, 6'-0" O.C. MAX)
1/2"
UNISTRUT FRAMING PER UNISTRUT DESIGNER
NEW HVAC DUCTWORK, SEE MEP PLANS
1/2"Ø A36 THREADED ROD
EXISTING CONCRETE SLAB
UNISTRUT PER UNISTRUT DESIGNER
UNISTRUT PER UNISTRUT DESIGNER
UNISTRUT CROSS BRACING PER UNISTRUT DESIGNER
ALL CONNECTIONS IN ACCORDANCE WITH
UNISTRUT DETAILS AND SPECIFCIATIONS
UNISTRUT BRACING PER UNISTRUT DESIGNER
ANCHORAGE FOR UNISTRUT BY OTHERS
(USE EXP OR EPOXY BOLTS) PROVIDE
EACH END AND MAX SPACING OF 24"
UNISTRUT PER UNISTRUT DESIGNER
B/ DUCT
EL= G.C. TO COORD W/ MEP
T/ DUCT
EL= SEE MEP
G.C. TO COORD W/ MEP
E Q
E Q
NOTE: G.C. TO PROVIDE OPENING IN EXSTING
BUILDING/STRUCTURE. G.C. TO PROVIDE
SIGNED AND SEALED LINTEL DETAIL FOR
APPROVAL PRIOR TO START OF WORK.
C E
R T
I F
IC
AT E
OF AUTHOR
I Z A
T I O
NENGINEERING
ADC
NO. 00253
INC.
S O
U
T H
C A R O L
I N
A
G
E W
B
A IR AS
I N 62 8
T H
IR
A
D
MAN
CO
M
MO
IT Y
B I L
SEAL AREA
OFSHEET
D
AT
E
P R E P
B Y
A P P R 'D
RECORD DRAWING DATE
DRAWING SIZE:
PROJECT NO.
D
EP
AR
TM
EN
T O F
TH
E
AI
R
FO
R C E
AI
R
M O B
IL
IT
Y C O M M
AN
D
R E V
D A T E
D E S C R
IP
T
IO
N
D R A W
IN
G
R E V
IS
IO
N S
C H
K
BY
D
R
AW
N B
Y:
D
SG
N
B Y:
SU
PV
C H
E N
G R
G
LI
C K
/B O
E H
M
A S
S O
C
IA
TE
S
, I N
C
K
IN
G S
TR
E
E T, S U
IT
E
C H
A R
LE
S
TO
N
, S C
J O
IN
T
B A S E
C H A R L E S T O N
C H A R L E S T O N S C
ARCH E(30X42)
07/27/2017
S222
TY
P
IC
AL
S
TE
EL
D
ET
AI
LS
A C
P A
C P
C
JG
/1
0/
JB
C
R
EP
AI
R
AI
R C R
AF
T
M
AI
N
TE
N
AN
C E H
AN
G
ER
ADC #17005.0
1" = 1'-0"3 SECTION
1" = 1'-0"5 SECTION
1" = 1'-0"4 TYP. HANDRAIL FRAMING
1" = 1'-0"1 TYP. HORIZ. THREADED ROD CONX.
1" = 1'-0"6
TYP. BEAM TO HSS CONN (FLUSH &
BRG)
1" = 1'-0"8 TYP. FLUSHED BEAM TO BEAM CONN
1" = 1'-0"9
TYP. HANDRAIL & CONN TO METAL
PLATFORM DETAIL
No. 28196
S O
UTH CAROL INA
L
IC
E
N S
E D
P
R O
F E S S I O N A
L E
N G
I N
E E
R
C H
R
IS
TOPHER J .
G
I L G
E
3/4" = 1'-0"11 SECTION 10
(2)-#5'S @ 8"/12" CMU,
(1)-#5 @ 6" CMU,
SEE TYPICAL OPENING DETAILS
STANDARD LINTEL BLOCK
TYPICAL STRETCHER UNITS
VERTICAL REINFORCING @
TYP. SPACING, EXTEND
INTO BOTTOM COURSE OF
LINTEL AS INDICATED
(8" DEEP, ONE COURSE)
(2)-#5'S EA COURSE, SEE
TYPICAL OPENING DETAILS
STANDARD LINTEL BLOCK,
TYP. BOTTOM COURSE
STANDARD OPEN BOTTOM
BOND BEAM COURSE
VERTICAL REINFORCING @ TYP.
SPACING, EXTEND INTO BOTTOM
COURSE OF LINTEL AS INDICATED
NOTES:
1. SUPPORT LINTEL BARS ON HORIZONTAL REBAR POSITIONERS @ 16" O.C. MAX TO ACHIEVE PROPER LOCATION
2. PROVIDE ADDITIONAL BARS, WIRE TIES, ETC. AS REQUIRED TO ENSURE LINTEL BARS ARE NOT DISPLACED DURING GROUTING
OPERATIONS
3. ALL VERTICAL REINFORCING SHALL EXTEND INTO BOTTOM COURSE OF LINTEL AS SHOWN.
4. ALL COURSES OF LINTELS SHALL BE GROUTED AT THE SAME TIME WITHOUT COLD JOINTS PRESENT BETWEEN THE COURSES.
5. SEE AND FOR TYPICAL CMU OPENING CONSTRUCTION.
6. WHERE LINTEL IS NOTED AS "CONT." IT IS CONTINUOUS ACROSS ADJACENT OPENINGS.
7. WHERE LINTEL IS NOTED AS "ABOVE" IT REFERS TO A SECOND LINTEL ABOVE A HIGHER OPENING.
8. ALLOWABLE SPANS ARE FOR MISCELLANEOUS OPENINGS NOT SPECIFICALLY INDICATED ON PLAN.
8.1 TYPE "L1" LINTELS SHALL BE LOCATED A MINIMUM OF (3)-COURSES BELOW FLOOR ELEVATION OR ROOF JOIST BEARING
ELEVATION.
8.2 TYPE "L2" LINTELS SHALL BE LOCATED A MINIMUM OF 3'-4" BELOW FLOOR ELEVATION OR ROOF JOIST BEARING ELEVATION.
9. DO NOT LOCATE LINTEL WITHIN 8" FROM END OF BEAM BEARING PLATE OR 1'-4" EACH SIDE OF CENTERLINE OF BEAM BEARING
ABOVE UNO.
10. PROVIDE MIN. 1'-4" CLEAR BETWEEN ADJACENT OPENINGS UNO.
11. TOP OF MECHANICAL OPENINGS NOTED BELOW SECOND FLOOR CONSTRUCTION SHALL NOT BE HIGHER THAN 12'-0" ABOVE
FIRST FLOOR FINISHED FLOOR UNO.
12. TOP OF MECHANICAL OPENINGS NOTED BELOW ROOF JOIST BEARING SHALL BE A MINIMUM OF 2'-0" BELOW JOIST BEARING
ELEVATION UNO.
(16" DEEP, TWO COURSES)
TYPE LINTELL2
TYPE LINTELL1
ALLOWABLE LINTEL SPANS
LINTEL TYPE ALLOWABLE SPAN
(NOTE #9)
< 2'-0"
2'-0" TO 4'-0"L2
/3 S231 /4 S231
L1
BEARING EACH END
MIN. 16" LINTEL
CMU LINTEL, SEE PLANS
AND SCHEDULES
JAMB REINFORCING,
SEE SCHEDULE
EXTEND WALL REINFORCING INTO
BOTTOM COURSE OF LINTEL
SEE TYP DETAIL FOR BOND
BEAM REINFORCING AT
OPENING
DOOR OPENING
NOTES:
1. JAMB BAR SIZE SHALL MATCH TYPICAL ADJACENT WALL REINFORCING SIZE
2. PROVIDE HORIZONTAL JOINT REINFORCEMENT @ 16" O.C. VERTICALLY AND FIRST COURSE ABOVE AND BELOW
OPENING, EXTEND MIN. OF 24" PAST OPENING
3. LINTELS SHALL BE CONSTRUCTED OF STANDARD "U" SHAPED UNITS (NOT BOND BEAM UNITS)
4. JAMB REINFORCING SHALL BE CONTINUOUS FROM FOOTING, GIRT, OR DIAPHRAGM LEVEL BELOW TO DIAPHRAGM
LEVEL, GIRT OR TOP OF WALL ABOVE
5. DETAIL IS TYPICAL ALL OPENINGS GREATER THAN 1'-0" WIDE
6. COORDINATE JAMB BARS WITH SPECIFIC CMU PIER DETAILS WHERE INDICATED
JAMB BAR SCHEDULE
EQUIVALENT
OPENING WIDTH
# OF…
This is the start of the file's text. The full file is on GovTribe.