This document appears to be a schematic drawing for the installation of a new satellite TV system on the NOAA Ship Henry Bigelow. The drawing provides details on the connections, splitters, and cabling required to upgrade the existing satellite TV system, including reuse of existing equipment where possible.

The related federal contract opportunity is a special notice for the NOAA Ship Henry Bigelow FY25 Dockside Repairs, solicitation number 1305M224R0041. This is for the NOAA Region 1 Dockside Repair and Ship Maintenance Indefinite Delivery, Indefinite Quantity (IDIQ) Contract Holders Only. The attached references, drawings, and manuals provide details on the required repairs and upgrades for this ship maintenance project.

View the file

Other files

File Type Posted
Wet Lab Conveyor System Parts Manual.pdf PDF
Immersion Suit Inventory (05-2-24).xlsx XLSX spreadsheet
HB-167-002 Wet Lab Door Modification REV A - Approved_143748972.pdf PDF
HB-583-03 (FRV40-225-093-010) Rescue Boat Handling System.pdf PDF
00 51 21.01 Vent Duct Cleaning.pdf PDF
HB-085 FF01 Insulation Arrangement.pdf PDF
Bigelow 2024 GMDSS Inspection Certificates.pdf PDF
3-ZF 63 Marine Propulsion Systems Operator_s Manual.pdf PDF
Steering Gear Handwheel Pump H330 and Piping Drawings.pdf PDF
HB-512 FV02 HVAC Diagram.pdf PDF
DWG MOCA-HB-434A-02 INSTALLATION Rev B (As Built).pdf PDF
Carsoe REPORT No 2 Conveyor Overhaul.pdf PDF
HB-631 FF04 Paint Schedule r1.0.pdf PDF
HB-170 FH22 Mast Rigging Flagstaff Layout Details.pdf PDF
HB-801 FC05 Tank Capacity Curves.pdf PDF
HB-167-001 Hydro Lab Door Modification REV A - Approved_143742608.pdf PDF
MarineTuff - Cat6 Cable Specification.pdf PDF
Immersion Suit Pressure Testing.pdf PDF
2-Volvo Penta D3 Operator_s Manual.pdf PDF
HB-985 FA05 Fire Control Plan.pdf PDF
SECNAV FORM 5512-NSNPT - JUL 2023 - HIGHLIGHTED.pdf PDF
Installation Guide TracVision UHD7 SWM Expansion Kit.pdf PDF
OLEX processor location and dimensions.pdf PDF
15732 Henry Bigelow_Lab Manual.pdf PDF
SECNAV FORM 5512 - Quick Guide.pdf PDF
HB-568 PE32 Bow Thruster Control System Terminal List.pdf PDF
Newport Naval Station Base Access Map.pdf PDF
New KVH UDH-7 and old Intellian HD6 Antenna footprint.pdf PDF
MOC-631-2D Coating Systems for Steel Surfaces.pdf PDF
4-HJ-274 Water Jet Installation and Service Manual.pdf PDF
FRV40-226-008-010 Bow Thruster Model 40 T3S.zip ZIP file
HB-506 FP02 Vents Sounds System Diagram.pdf PDF
HB-085 FA02 General Arrangements.pdf PDF
HVAC Systems for Duct Cleaning (04-25-24).xlsx XLSX spreadsheet
AMC-583-1B General Requirements for Liferaft Inspections.pdf PDF
Installation Guide - TracVision UDH7 - 54-1308_UHD7_IG.pdf PDF
00 00 01.07 General Requirements.pdf PDF
FRV40-225-058-010 Motor Propulsion DC.pdf PDF
Bigelow Direct TV Box Inventory March 2024.xlsx XLSX spreadsheet
Newport Naval Station-Pier 2 Load Restrictions 7-15-19.pdf PDF
Bow Thruster HMI Cutout Pictures.pdf PDF
IEEE 45 Recommended Practice for Electrical Installations on Shipboard.pdf PDF
HB Fire System Inventory (05-3-24).xlsx XLSX spreadsheet
Rescue Boat Manual - 670 SOLAS - Willard Marine.zip ZIP file
Siemens Report - How to built a NOAA SPDM.pdf PDF
HB-512 FV04 Fan List.pdf PDF
HB-561 02 (FRV40-225-128-010) Steering Gear Model 1xSR662.pdf PDF
HB Fire System Inspection Report - FEB 2024.pdf PDF
13603 Manual Complete.pdf PDF
Show all 49

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Flying Bridge – Main Mast 04 Deck

Bridge/Radio Chart

RE‐use existing +12V DC power from removed

ACU

SPLIT4MRV x4 #1 SPLIT4MRV x4 #2 SPLIT4MRV x4 #3 SPLIT4MRV x4 #4

RE‐use existing AC connection from removed swtich

RE‐use existing AC connection from removed swtich

Out1 Out1 Out1

Out1

Out

Out

Out

Out

Out 2Out

Out

Out

Out

Out

Out

Out

Out

SWM 16

#1

SWM 16

#3

SWM 16

#4

SWM 16

#2

RE‐use existing AC connection from removed swtich

RE‐use existing AC connection from removed swtich

02‐29‐1 CO SR

02‐39‐1 Chief Scientist SR

02‐29‐0 FOO SR

02‐29‐2 CME SR

02‐38‐2 1st Engr SR

02‐45‐0 XO SR

02‐46‐2 XO SR

Mess

Lounge

Office

01‐33‐4

01‐28‐2

01‐24‐4

01‐19‐2

SPLIT8MRV

OUTPUT TO SET

H25 SET TOP

RECEIVERS

SPLIT8MRV

OUTPUT TO SET

TOP RECEIVERS

SPLIT8MRV

OUTPUT TO H25

SET TOP

RECEIVERS

SPLIT8MRV (x2)

OUTPUT TO H25

SET TOP

RECEIVERS

222‐2 SR

239‐5 SR

222‐1 SR

231‐5 SR

229‐4 SR

234‐2 SR

244‐1 SR

239‐4 SR

329‐4 DER

244‐2 SR

Forward Lounge 01‐19‐1

MAIN DECK – CHEM LAB

01 DECK – ET SHOP

SAT TV JUNCTION BOX

231‐3 SR

B

A A

A

A

B B

B

B

C C

C

C

D D

D

D

B

A

A

C

C

D

D

TO

SHEET 3

SWM #3

INPUTS

TO

SHEET 3

SWM #4

INPUTS

FR

O M

SH

EE

T

FR

O M

SH

EE

T

Drawing No: MOCA‐HB‐434A‐02

SHEET 1 OF 4

Drawing No: MOCA‐HB‐434A‐02

Drawing No:

MOCA‐HB‐

434A‐02

SHEET 2 OF 3

SHEET 3 OF 3

x x xx x

OUT 1 OUT 2 OUT 3 OUT 4

18V 13V 18V 22KHz

13V 22KHz

To Bridge PC Re‐use existing cable and port

NOTES

1) Sat TV Service Direct TV

2) All coax cables run from Main Mast Antenna are RG11. All other coax is RG6.

3) UHD7 Antenna modified with SWM expansion kit 72‐0897 supporting up to 52 tuners.

4) Green highlighted cables are to be newly run or available spares to support UHD7 upgrade.

5) Black cables are existing to be reused.

6) Terminate all unused splitter outputs with 75 ohm terminaters.