Contract Att04 - BLS - Responder Decomm Checklist.pdf
PDF 155 KB Posted
- Solicitation number
- 70T04020R9AP4050
About this file
This decommissioning checklist is used to document the removal of Smiths RespondeR Bottled Liquid Scanner systems from airports. It requires photos and inspections of equipment components and packaging to identify any damage. Functional tests include verifying system detection capabilities, calibration, and login. Cleaning of lens areas is also specified. Sign-offs are required from system integrators and federal employees to confirm all documentation and removal procedures were properly completed on-site.
The related federal contract opportunity is a Request for Proposal for Checkpoint Screening Equipment Deployment Services issued by the Transportation Security Administration within the Department of Homeland Security. Interested offerors are directed to the attached RFP for details regarding providing security equipment deployment services to TSA checkpoints. Questions may be submitted using the provided template. Relevant information includes the solicitation number, opportunity type, issuing agency, and instruction to review the RFP package for full requirement details.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Section Yes No
Take a photo of the FRONT of the unit and document any damage or concerns.
Take a photo of the SIDES of the unit and document any damage or concerns.
Take a photo of the BACK of the unit and document any damage or concerns.
In v en to ry
RespondeR BLS System?
Power Supply with AC Adapter?
Safety Enclosure?
(Should be attached to the RespondeR BLS)
Clear Sticker Dispenser?
(Should be attached to the Safety Enclosure)
Subcontractor Contact Information and Verification
Printed Name
Sign and date this Decommission Checklist and leave a copy with the unit.
Performed By:
V is u a l
V er if ic a ti o n
U n it
C o n d it io n
Is the labeling correct on the packaging?
"Abnormal Object" Test Sample with Red Label?
(NO PASS)
System Keys?
Does the unit have any Exterior Damage?
(i.e. broken pieces, dents, paint chipping, locally added stickers)
Does the unit have Interior Damage?
(i.e. broken pieces, dust, locally added stickers)
T es ti n g
Does the system turn on?
Does the system allow users to Log On?
Take photo of the unit PACKAGED for shipping and document any damage or concerns.
U n it
P a ck a g in g
Take a photo of the unit while OPERATIONAL and document any damage or concerns. (screen included)
The comments/concerns section may be used to provide further detail concerning unit quality, quantity, or general notes on unit/part condition
Decommission Checklist For the Smiths RespondeR
Bottled Liquid Scanner (BLS)
Operation Test Kit (OTK)?
Take a photo of the MAKE/MODEL of the unit and document any damage or concerns.
Take a photo of the SERIAL NUMBER and BARCODE on the unit and document any damage or concerns.
BLS S/N: TSA/FAA Bar Code Number:
Airport Code: Terminal: Date of Test: Time:
Did the system pass the System Detection Verification Check Successfully?
Does the system calibrate correctly?
Comments/ConcernsEvaluation Criteria
Email Address Phone Number
Signature DateCompany Name
C le an in g Using a cotton tip applicator, gently clean the lens area to remove any dust or debris.
Using no chemicals, wipe off any dust or debris from the viewing windows.
Yes No
Signature Date
Evaluation Criteria Comments/Concerns
System Integrator Section (This section should be filled in by the System Integrator ONLY)
Has all damage been documented? If NO, please specify in the comments section.
Systems Integrator Additional Comments
Are there any components missing? If YES, please specify in the comments section.
Is a Verification Kit being returned with this unit? If YES, please note it in the comments section.
DateSignature
Federal Employee Comments/Concerns
Federal Employee Verification
As a witness, sign and date this Decommission Checklist to confirm the document was completed on-site.
Confirmed By:
Printed Name
Systems Integrator Contact Information and Verification
Sign and date this Decommission Checklist and leave a copy with the unit.
Reviewed By:
Printed Name Email Address Phone Number
Company Name