BLDG D Combined Drawings.pdf
PDF 7 MB Posted
- Solicitation number
- N4008021R6986
About this file
This is a solicitation for a design-bid-build construction project. The project involves constructing a new single-story Marine Corps Reserve Center facility, a single-story vehicle maintenance facility, and a single-story organic storage shed at Marine Corps Reserve Center, Camp Fretterd, MD. The primary facility will be a 35,130 SF building for an armory, drill hall, lockers, classrooms, fitness center, supply storage, offices, and a covered weapons cleaning area. The vehicle maintenance facility will be 10,968 SF for vehicle bays, offices, and a carpentry shop with an outdoor vehicle wash platform. The organic storage shed will be 4,000 SF. The work includes reinforced concrete slabs, foundations, and a concrete block and steel frame structure with brick exterior and standing seam metal roofing. The solicitation is issued by the Naval Facilities Engineering Command, Department of the Navy.
View the file
Other files
Show 40 more
Latest 50 of 55 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
A
B
C
D
1 2 3 4 5
DRAWFORM REVISION: 10 MARCH 2009
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
E P A R
TM
E N T O F
TH
E
N A V Y
N
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
<<PM-DM>> ZN/DP
BRANCH MANAGER DAW
CHIEF ENG/ARCH THC
FIRE PROTECTION JTG
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
VICINITY MAP
P303 MARINE CORPS RESERVE CENTER
04/16/2021
4/
/2
9:
:5
PM
WASHINGTON NAVY YARD
PUMP ENCLOSURE
IFC SUBMISSION APRIL 16, 2021
NAVAL FACILITIES ENGINEERING COMMAND, WASHINGTON
CAMP FRETTERD
_G
-0
-C O
VE
R
S H
EE
T
D_G-001
RE
IS
TE
RS
TO
W N M
AR
YL
AN
13134100
1624807
ER ER WS
VE
SH
AM
P
FR
ET
TE
RD
PU
M
EN
LO
SU
AV
AL
F
AC
IL
IT
IE
G
IN
, W
AS
TO
W
AS
H
IN
GT
O
.C
H
IN
G
TO
N
N
AV
Y
YA
WASHINGTON D.C.
REISTERSTOWN, MARYLAND
AR
K
ES
IP
TI
AT
AP
PR
dagoberto.portillo
New Stamp
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
AS NOTED
_G
-S
EX
D_G-002
TE
RS
TO
W N M
AR
YL
13134101
ER ER WS
T
IN
DE
X
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
PUMP ENCLOSURE SHEET INDEX
CURRENT
NUMBER Sheet Number
NAVFAC
DRAWING
NUMBER Sheet Name
GENERAL
1 D_G-001 13134100 COVER SHEET
2 D_G-002 13134101 SHEET INDEX
STRUCTURAL
3 D_S-001 13134102 GENERAL NOTES
4 D_S-002 13134103 ABBREVIATIONS, LEGEND, AND LOAD DIAGRAM
5 D_S-101 13134104 STRUCTURAL PLANS, ELEVATIONS, AND SECTIONS
6 D_S-501 13134105 TYPICAL DETAILS
7 D_S-502 13134106 TYPICAL DETAILS
ARCHITECTURE
8 D_A-001 13134107 GENERAL NOTES, ABBREVIATIONS
9 D_A-101 13134108 PLANS
10 D_A-201 13134109 ELEVATIONS
11 D_A-301 13134110 BUILDING AND WALL SECTIONS
12 D_A-501 13134111 WALL DETAILS
13 D_A-601 13134112 SCHEDULES AND DIAGRAMS
FIRE PROTECTION
14 D_F-001 13134113 GENERAL NOTES
15 D_F-101 13134114 FIRE PUMP PLAN
16 D_F-501 13134115 DETAILS SHEET
17 D_F-502 13134116 FIRE MATRIX
PLUMBING
18 D_P-101 13134117 PLUMBING FLOOR PLAN, RISER & DETAILS
MECHANICAL
19 D_MH001 13134118 HVAC LEGEND
20 D_MH101 13134119 HVAC FLOOR PLAN
21 D_MH501 13134120 HVAC DETAILS
22 D_MH601 13134121 HVAC SCHEDULES
23 D_MH701 13134122 HVAC CONTROLS
24 D_MP001 13134123 MECHANICAL PROCESS LEGEND
25 D_MP101 13134124 MECHANICAL FLOOR PLAN
26 D_MP301 13134125 MECHANICAL PROCESS SECTIONS
27 D_MP302 13134126 MECHANICAL PROCESS SECTION AND SCHEDULES
28 D_MP501 13134127 MECHANICAL PROCESS DETAILS
29 D_MP901 13134128 MECHANICAL PROCESS ISOMETRIC VIEWS
30 D_MI001 13134129 INSTRUMENTATION LEGEND AND ABBREVIATIONS
31 D_MI002 13134130 P&ID FIRE SUPPLY STORAGE TANK
32 D_MI003 13134131 P&ID MECHANICAL PROCESS PUMP ENCLOSURE
ELECTRICAL
33 D_E-001 13134132 ELECTRICAL LEGEND AND ABBREVIATIONS
34 D_E-101 13134133 ELECTRICAL LIGHTING AND POWER FLOOR PLANS
35 D_E-112 13134134 LIGHTNING PROTECTION PLAN
36 D_E-501 13134135 ELECTRICAL LIGHTING DETAILS
37 D_E-502 13134136 ELECTRICAL LIGHTING PHOTOMETRICS
38 D_E-503 13134137 LIGHTNING PROTECTION DETAILS
39 D_E-504 13134138 ELECTRICAL DETAILS
40 D_E-505 13134139 ELECTRICAL DETAILS
41 D_E-506 13134140 ELECTRICAL DETAILS
42 D_E-601 13134141 ELECTRICAL POWER RISER DIAGRAM
43 D_E-602 13134142 ELECTRICAL GROUNDING DIAGRAM
44 D_E-611 13135420 ELECTRICAL SCHEDULES
45 D_E-621 13135421 ELECTRICAL PANEL SCHEDULES
D_G-001 - COVER SHEET
D_G-002 - SHEET INDEX
2021-04-14T11:23:26-0400
Peter Soukas
I am signing to certify the authenticity of this document.
2021-04-14T11:23:55-0400
Peter Soukas
I am signing to certify the authenticity of this document.
1. ELEVATIONS NOTED ON THE STRUCTURAL DRAWINGS ARE
RELATIVE TO MEAN SEA LEVEL DATUM.
2. DETAILS LABELED "TYPICAL DETAILS" OR DETAILS ON "TYPICAL
DETAILS" SHEETS APPLY TO SITUATIONS THAT ARE THE SAME
OR SIMILAR TO THOSE SPECIFICALLY DETAILED. SUCH DETAILS
AND DIMENSIONS APPLY WHETHER OR NOT DETAILS ARE
REFERENCED AT EACH LOCATION.
3. SLOPING DECK PLANES ARE USUALLY DEFINED BY A WORK
POINT ELEVATION AND A SLOPE. STEEL MEMBERS
SUPPORTING A SLOPING DECK PLANE HAVE THEIR TOP OF
STEEL COINCIDENT WITH THE BOTTOM OF DECK.
1. REVIEW AND VERIFY ACTUAL EQUIPMENT DIMENSIONS USING
APPROVED MANUFACTURER/ VENDOR DRAWINGS PRIOR TO
SUBMISSION OF SHOP DRAWINGS.
2. REVIEW AND VERIFY LOCATION OF CHASES, INSERTS,
OPENINGS, SLEEVES, FINISHES, DEPRESSIONS, PADS, AND
WALL OPENINGS. COORDINATE WITH ALL OTHER DISCIPLINE
SHEETS.
3. DO NOT SCALE DRAWINGS FOR THE PURPOSE OF
ESTABLISHING DIMENSIONS.
4. DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON
FLOORS/ROOFS IN EXCESS OF 80 PERCENT OF LIVE LOAD.
5. PROVIDE BRACING AND SHORING TO MAINTAIN THE STABILITY
OF, AND TO AVOID OVER-LOADING, THE STRUCTURE DURING
CONSTRUCTION. THE STRUCTURE IS DESIGNED FOR THE
COMPLETED CONDITION ONLY.
6. CUT NO HOLES IN STRUCTURAL MEMBERS WITHOUT WRITTEN
APPROVAL FROM THE COR.
1. COMPLY WITH THE REQUIREMENTS OF SPECIFICATION
SECTION 01 45 35, STRUCTURAL TESTS AND INSPECTIONS.
THE STRUCTURAL DESIGN CONFORMS TO THE FOLLOWING
CODES/STANDARDS:
1. UFC 1-200-01 DOD BUILDING CODE (8 OCTOBER 2019)
2. UFC 3-220-01 GEOTECHNICAL ENGINEERING (1 NOVEMBER 2012)
3. UFC 3-301-01 STRUCTURAL ENGINEERING (1 OCTOBER 2019)
4. UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR
BUILDINGS (12 DECEMBER 2018)
5. IBC 2018 INTERNATIONAL BUILDING CODE, AS MODIFIED BY THE
UFC
6. ASCE/SEI 7–16 MINIMUM DESIGN LOADS FOR BUILDINGS AND
OTHER STRUCTURES, AS MODIFIED BY THE UFC
1. SERVICEABILITY DESIGN FOR DEFLECTION CONFORMS TO IBC
2018 AND ASCE 7-16 APPENDIX C AND COMMENTARY AS
MODIFIED BY THE UFC.
A. VERTICAL LIMITS BASED ON UNFACTORED LOADS: 1/360
OF SPAN OF MEMBERS SUBJECTED TO FULL NOMINAL
LIVE LOAD, 1/240 OF SPAN OF MEMBERS SUBJECTED TO
DEAD PLUS LIVE LOAD.
B. LATERAL LIMITS: 1/480 OF BUILDING HEIGHT BASED ON
THE 10 YEAR MEAN RECURRENCE INTERVAL WIND
SPEED.
1. FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL
INVESTIGATION REPORT BY ECS MID-ATLANTIC, LLC, ENTITLED
"REPORT OF SUBSURFACE EXPLORATION, LABORATORY
TESTING, AND GEOTECHNICAL ENGINEERING ANALYSIS,"
DATED MAY 31, 2019. THE DESIGN OF FOUNDATIONS UTILIZES
THE FOLLOWING PARAMETERS:
A. ALLOWABLE NET BEARING CAPACITY OF 3,000 PSF
B. DENSITY OF NEW FILL MATERIAL: 120 PCF
C. SUBGRADE MODULUS, K1: 120 PCI
D. ACTIVE EARTH PRESSURE COEFFICIENT, Ka: 0.33 E. AT REST EARTH PRESSURE COEFFICIENT, Ko: 0.50 F. PASSIVE EARTH PRESSURE COEFFICIENT, Kp: 3.00
G. COEFFICIENT OF FRICTION FOR SLIDING: 0.35
2. FROST DEPTH: 30 INCHES
3. BELOW SLABS-ON-GRADE PROVIDE: VAPOR BARRIER AND MIN 4
INCH THICK POROUS FILL CONSISTING OF #57 STONE, CR-6, OR
GASB DENSE-GRADED AGGREGATE.
1. CONCRETE DESIGN CONFORMS TO ACI 318–14 BUILDING CODE
REQUIREMENTS FOR STRUCTURAL CONCRETE, AS MODIFIED
BY THE UFC.
2. CONCRETE REINFORCING
A. REINFORCING BARS: ASTM A615, GRADE 60, DEFORMED.
B. WELDED WIRE: ASTM A1064, PLAIN.
3. MINIMUM 28-DAY COMPRESSIVE STRENGTHS:
A. WALL FOOTINGS: 4,000 PSI
B. SLABS-ON-GROUND: 4,000 PSI
C. OTHER STRUCTURAL CONCRETE: 4,000 PSI
4. COVER FOR CONCRETE REINFORCEMENT - CAST IN PLACE:
A. CAST AGAINST AND PERMANENTLY IN CONTACT WITH
GROUND: 3 INCHES
B. EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
3 INCHES
C. NOT EXPOSED TO WEATHER OR IN CONTACT WITH
GROUND:
1. SLABS: #11 AND SMALLER, 1 INCH.
5. UNLESS NOTED OTHERWISE, WELDED WIRE FABRIC
REINFORCEMENT TO BE PLACED AT MID-HEIGHT OF THE SLAB.
6. WELDING OF REINFORCING BARS IS NOT PERMITTED.
NOTES:
(1) TOP BARS AS DEFINED AS ANY BARS IN WHICH THE DEPTH OF
THE CONCRETE CAST IN ONE LIFT BENEATH THE BARS EXCEEDS
1'-0".
(2) CASE 1: CLEAR SPACING OF BARS DEVELOPED OR SPLICED
NOT LESS THAN db, CLEAR COVER NOT LESS THAN db, AND STIRRUPS OR TIES THROUGHOUT Ld NOT LESS THAN THE CODE MINIMUM OR
CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED NOT LESS
THAN 2db AND CLEAR COVER NOT LESS THAN db.
CASE 2: BARS DEVELOPED OR SPLICED WITH CLEAR COVER
AND/OR SPACING NOT MEETING THE REQUIREMENTS OF CASE 1.
(3) SPLICE LENGTHS:
a. CLASS A TENSION SPLICE = 1.0 Ld, 12 in MIN
b. CLASS B TENSION SPLICE = 1.3 Ld, 12 in MIN
c. COMPRESSION SPLICE = 30db, 12 in MIN
(4) VALUES IN TABLES ARE FOR UNCOATED REBAR ONLY.
1. STRUCTURAL STEEL DESIGN CONFORMS TO AISC 360–16
SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, AS
MODIFIED BY THE UFC.
2. STRUCTURAL STEEL MATERIALS:
A. ANGLES AND CHANNELS: ASTM A36
B. PLATE AND BAR: ASTM A36
C. WELDING ELECTRODES: COMPLY WITH AWS
REQUIREMENTS. PROVIDE FILLER METAL WITH A MINIMUM
TENSILE STRENGTH OF 70 KSI.
3. BOLTS, CONNECTORS AND ANCHORS:
A. HIGH-STRENGTH BOLTS: ASTM F3125 GRADES A325 OR
A490, TYPE 1, HEAVY-HEX STRUCTURAL STEEL BOLTS
B. NUTS: ASTM A563, GRADE C, HEAVY-HEX CARBON STEEL
NUTS
C. WASHERS: ASTM F436, TYPE 1, HARDENED CARBON-
STEEL WASHERS; ALL WITH PLAIN FINISH
D. UNHEADED ANCHOR RODS: ASTM F1554, GRADE 36
E. HEADED ANCHOR RODS: ASTM F1554, GRADE 55- S1
(WELDABLE)
F. THREADED RODS: ASTM A36
4. DO NOT SPLICE STRUCTURAL MEMBERS EXCEPT WHERE
INDICATED ON THE DRAWINGS.
5. HOT DIP GALVANIZE ELEMENTS EXPOSED TO WEATHER.
1. STEEL DECKING DESIGN CONFORMS WITH SDI ANSI/RD1.0–10
STANDARD FOR ROOF DECK, AS MODIFIED BY THE UFC.
2. ROOF DECKING TO BE 1 1/2" DEEP, 18 GAGE, WIDE RIB DECK
SPANNING PERPENDICULAR TO SUPPORTS IN A THREE-SPAN
CONDITION WITH THE FOLLOWING MINIMUM PROPERTIES:
A. I = 0.295 IN4/FT
B. S = 0.327 IN3/FT
C. Fy = 33 KSI
3. FASTEN DECKING WITH 5/8" DIAMETER PUDDLE WELDS WITH A
36/4 PATTERN. PROVIDE MINIMUM TWO #10 SIDELAP SCREWS
PER SPAN.
1. MASONRY DESIGN CONFORMS TO TMS 402/602-2016 BUILDING
CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY
STRUCTURES, AS MODIFIED BY THE UFC.
2. MASONRY NET AREA COMPRESSIVE STRENGTH AT 28-DAYS:
2,000 PSI.
3. MASONRY DESIGN STRENGTH, f'm: 2,000 PSI
4. REINFORCING BARS: ASTM A615, GRADE 60, DEFORMED. LAP
REINFORCING BARS AS FOLLOWS:
A. #5 BARS AND SMALLER: 24"
B. #6 BARS: 38"
5. UNLESS NOTED OTHERWISE, PROVIDE BOND BEAMS AS
FOLLOWS:
A. CONTINUOUS WITH 2-#5 AT EACH STRUCTURALLY
CONNECTED ROOF AND FLOOR ELEVATION.
B. CONTINUOUS WITH 2-#5 AT WALL OPENINGS EXTENDING
NOT LESS THAN 24 INCHES PAST EACH END OF THE
OPENINGS.
6. UNLESS NOTED OTHERWISE, REINFORCE MASONRY WALLS AS
FOLLOWS:
A. HORIZONTAL REINFORCEMENT: PROVIDE GALVANIZED
W2.8x2.8 LADDER TYPE HORIZONTAL BED JOINT
REINFORCEMENT AT 16 INCHES OC.
B. VERTICAL REINFORCEMENT:
a. #5 @ 32" OC
b. PROVIDE AT LEAST ONE #5 VERTICAL AT THE
FOLLOWING LOCATIONS:
• WITHIN 16 INCHES OF EACH SIDE OF
OPENINGS
• WITHIN 8 INCHES OF EACH SIDE OF
MOVEMENT JOINTS
• WITHIN 8 INCHES OF ENDS OF WALLS
7. MASONRY INSTALLED BELOW GRADE TO BE FULLY GROUTED.
8. PLACE CONTROL JOINTS AT MIDSPAN OF WALLS UON ON THE
DRAWINGS. DO NOT PLATE CONTROL JOINTS IN PORTIONS OF
WALLS BELOW GRADE.
9. LINTELS MUST BEAR A MINIMUM OF 8 INCHES AT EACH END.
USE ANY OF THE FOLLOWING LINTELS WHEN THE HEAD OF THE
MASONRY OPENING IS BELOW FLOOR OR ROOF BEARING
ELEMENTS BY A MINIMUM OF 75% OF THE LINTEL SPAN,
UNLESS OTHERWISE NOTED ON PLAN:
A. CMU LINTELS PER 8" CMU THICKNESS:
a. 0 TO 4 FEET 8 INCH DEEP WITH 2-#5 BOT
b. 4 TO 6 FEET 8 INCH DEEP WITH 2-#5 BOT
c. 6 TO 8 FEET 16 INCH DEEP WITH 2-#5 BOT
B. STEEL LINTEL PER 4" BRICK:
a. 0 TO 8 FEET L4x3-1/2x3/8 LLV
DELEGATED DESIGN TO BE IN ACCORDANCE WITH THE
SPECIFICATIONS.
1. OPEN WEB STEEL JOISTS
1. DESIGN AND MANUFACTURE JOISTS TO COMPLY WITH THE
REQUIREMENTS OF THE STANDARD SPECIFICATIONS LOAD
TABLES AND WEIGHT TABLES FOR STEEL JOISTS AND JOIST
GIRDERS, SJI 100, FOR THE JOIST DESIGNATIONS INDICATED
ON THE DRAWINGS.
2. DESIGN JOISTS FOR 100 LB POINT LOAD ON BOTTOM CHORD
ANYWHERE ALONG ITS LENGTH.
3. JOIST BRIDGING, INCLUDING ALL CONNECTIONS, SHALL BE
DESIGNED BY THE JOIST DESIGNER IN ACCORDANCE WITH SJI
REQUIREMENTS.
4. DESIGN JOISTS AND JOIST UPLIFT BRIDGING TO RESIST A NET
ULTIMATE UPLIFT PRESSURE OF 41 PSF.
5. DO NOT CUT HOLES OR NOTCHES IN CHORD AND WEB
MEMBERS, UNLESS APPROVED BY THE JOIST DESIGNER AND
THE CONTRACTING OFFICER.
6. DO NOT APPLY TEMPORARY OR PERMANENT LOADS TO JOIST
BRIDGING.
7. DESIGN JOIST BEARING FOR A HORIZONTAL OUT-OF-PLANE
ROLLOVER FORCE OF 600 LBS PER JOIST.
1. MATERIALS:
A. CARBON STEEL WEDGE ANCHOR STUDS: ASTM A 510 OR
ASTM A 108.
B. NUT & WASHER: COMPATIBLE WITH STUD MATERIAL &
FINISH.
C. CARBON STEEL THREADED ROD: ISO 898 CLASS 5.8.
D. CONCRETE REINFORCING DOWELS: ASTM A 615, GRADE
E. MESH SCREEN TUBE: CYLINDRICAL SHAPE WITH ONE
END CLOSED MANUFACTURED FROM ZINC PLATED LOW
CARBON STEEL OR STAINLESS STEEL. MESH SIZE,
DIAMETER, AND LENGTH AS SPECIFIED BY ADHESIVE
MANUFACTURER.
2. MECHANICAL ANCHORS AND THREADED INSERTS TO BE
CARBON STEEL WITH ZINC PLATING IN ACCORDANCE WITH
ASTM B 633,TYPE III Fe/Zn 5 (SC1), UNLESS NOTED OTHERWISE.
3. POST-INSTALLED ANCHORS MANUFACTURED BY HILTI, INC.
ARE SPECIFIED AS A BASIS OF DESIGN AND TO ESTABLISH THE
DESIRED QUALITY AND PERFORMANCE OF THE WORK. OTHER
APPROVED MANUFACTURERS ARE:
A. SIMPSON STRONG TIE.
B. DEWALT FASTENERS.
4. ANCHORING TO CONCRETE: TYPE AND SIZE AS INDICATED.
A. MECHANICAL ANCHORS:
a. MECHANICAL ANCHORS USED IN CONCRETE MUST
BE TESTED AND PREQUALIFIED FOR
PERFORMANCE IN CRACKED AND UNCRACKED
CONCRETE IN ACCORDANCE WITH ACI 355.2 AND
ICC-ES AC193, INCLUDING SEISMIC SHEAR AND
TENSION.
b. EXPANSION ANCHORS: WEDGE TYPE, TORQUE
CONTROLLED ANCHORS.
B. ADHESIVE ANCHORS:
a. ANCHORS CONSISTING OF AN INSERT AND
CARTRIDGE TYPE, TWO COMPONENT, EPOXY OR
HYBRID ADHESIVE DISPENSED AND MIXED
THROUGH A STATIC MIXING NOZZLE PROVIDED BY
THE ADHESIVE MANUFACTURER.
b. ADHESIVE TO BE TESTED AND PREQUALIFIED FOR
PERFORMANCE IN CRACKED AND UNCRACKED
CONCRETE IN ACCORDANCE WITH ICC-ES AC308,
INCLUDING SEISMIC SHEAR & TENSION,
HORIZONTAL AND OVERHEAD INSTALLATIONS, AND
LONG TERM CREEP.
5. ANCHORING TO GROUT FILLED OR HOLLOW CONCRETE
MASONRY: TYPE AND SIZE AS INDICATED
A. ADHESIVE ANCHORS
a. ANCHORS CONSISTING OF AN INSERT AND
CARTRIDGE TYPE, TWO COMPONENT, EPOXY OR
HYBRUD ADHESEIVE DISPENSED AND MIXED
THROUGH A STATIC MIXING NOZZLE PROVIDED BY
THE ADHESIVE MANUFACTURER.
b. PROVIDE A MESH SCREEN TUBE WHEN ANCHORING
TO HOLLOW CONCRETE MASONRY.
c. ADHESUVE MUST HAVE BEEN TESTD AND
PREQUALIFIED IN ACCORDANCE WITH ICC-ES AC58,
INCLUDING FREEZE-THAW CONDITIONS, CRITICAL
AND MINIMUM EDGE DISTANCE AND SPACING, AND
LONG-TERM CREEP.
6. ADHESIVE ANCHORS MUST BE TENSION PROOF LOADED TO
THE GREATER OF 50 PERCENT OF EXPECTED ADHESIVE
ULTIMATE STRENGTH OR 80 PERCENT OF STEEL YIELD
STRENGTH OF THE ANCHOR RODS. PROOF LOADING MUST BE
PERFORMED AFTER A MINIMUM CURING PERIOD SPECIFIED BY
THE MANUFACTURER.
7. IDENTIFY POSITION OF REINFORCING STEEL AND OTHER
EMBEDDED ITEMS PRIOR TO DRILLING HOLES FOR ANCHORS.
EXERCISE CARE IN DRILLING TO AVOID DAMAGING EXISTING
REINFORCING OR EMBEDDED ITEMS. STOP DRILLING AND
NOTIFY THE COR IF REINFORCING STEEL OR OTHER
EMBEDDED ITEMS ARE ENCOUNTERED DURING DRILLING.
8. INSTALL ANCHORS IN DRY HOLES IN ACCORDANCE WITH
MANUFACTURER’S PRINTED INSTRUCTIONS. EMBED ANCHORS
INTO THE SUBSTRATE AS INDICATED IN THE POST-INSTALLED
ANCHOR SCHEDULE UON.
POST-INSTALLED ANCHOR SCHEDULE NOTES:
MINIMUM EFFECTIVE EMBEDMENT IS BASED ON THE SPECIFIED
ANCHOR MANUFACTURED BY HILTI, INC. ANCHORS BY OTHER
MANUFACTURERS MAY REQUIRE DEEPER EMBEDMENT TO
ACHIEVE COMPARABLE STRENGTHS. ANCHORS ARE ASSUMED
TO BE EMBEDDED IN CRACKED CONCRETE.
POST-INSTALLED ANCHOR SCHEDULE
ANCHORING TO NORMAL AND LIGHT WEIGHT CONCRETE
ANCHOR TYPE
BASIS OF DESIGN
EXPANSION
ANCHOR
KWIK BOLT TZ
ADHESIVE ANCHOR
HY 200-R
ADHESIVE ANCHOR
RE 500 V3
ANCHOR
DIAMETER
MIN EFFECTIVE
EMBEDMENT, UON
1/2" 5/8" 3/4"
1/2" - 1"
#3 - #8
3 1/4" 4"
4 3/4"
AS INDICATED ON
DWGS
AS INDICATED ON
DWGS
SUPERIMPOSED DEAD LOAD
A. SOG: 120 PSF
(EQUIPMENT PAD, WATER HEATER)
B. ROOF: 27 PSF
2. FLOOR LIVE LOAD (NON-REDUCIBLE)
A. SOG: 150 PSF UNIFORM
3. ROOF LIVE LOAD (NON-REDUCIBLE): 20 PSF
4. SNOW
A. GROUND SNOW LOAD: 25 PSF
B. FLAT-ROOF SNOW LOAD: 24 PSF
C. SNOW LOAD IMPORTANCE FACTOR: 1.2
D. THERMAL FACTOR: 1.1
5. WIND
A. ULTIMATE DESIGN WIND SPEED: 125 MPH
B. RISK CATEGORY: IV
C. WIND EXPOSURE: C
D. INTERNAL PRESSURE COEFFICIENT: +/-0.18
E. 10 YEAR MRI WIND SPEED: 75 MPH
F. NORTH-SOUTH DESIGN BASE SHEAR: 8 KIP
G. EAST-WEST DESIGN BASE SHEAR: 5 KIP
6. EARTHQUAKE
A. RISK CATEGORY: IV
B. SEISMIC IMPORTANCE FACTOR: 1.25
C. SS: 0.145 g S1: 0.044 g
D. SITE CLASS: C
E. SDS: 0.126 g SD1: 0.044 g
F. SEISMIC DESIGN CATEGORY: A
G. DESIGN BASE SHEAR: 5.5 KIP
H. SEISMIC RESPONSE COEFFICIENT, CS: 0.079
I. SEISMIC FORCE-RESISTING SYSTEM:
a. ORDINARY REINFORCED MASONRY SHEAR WALLS
• RESPONSE MODIFICATION COEFFICIENT, R: 2
• OVERSTRENGTH FACTOR, Ω0: 2.5
• DEFLECTION AMPLIFICATION FACTOR, Cd: 1.75
J. ANALYSIS PROCEDURE USED: DESIGNED FOR GENERAL
STRUCTURAL STABILITY AS PER ASCE 7-16 SECTION 1.4.
DRAWING ORGANIZATION
CONSTRUCTION REQUIREMENTS
STRUCTURAL TESTS AND
INSPECTIONS
DESIGN CRITERIA
DESIGN LOADS
SERVICEABILITY
GEOTECHNICAL
CONCRETE
STRUCTURAL STEEL
STEEL DECKING
MASONRY
DELEGATED DESIGN
POST INSTALLED ANCHORS
OPEN WEB STEEL JOISTS
REINFORCING BAR DEVELOPMENT LENGTHS (INCHES), 4000 PSI
#3 #4 #5 #6
CASE 1 CASE 2
OTHER BARSTOP BARS
CASE 1
CASE 2
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
:0
_S
-G
ER
D_S-001
TE
RS
TO
W N M
AR
YL
13134102
SAK SAK TJH
GE
ER
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
& AND
@ AT
AB ANCHOR BOLT
ABV ABOVE
ACI AMERICAN CONCRETE INSTITUTE
ADDL ADDITIONAL
ADH ADHESIVE
ADJ ADJACENT
AE AIR ENTRAINED
AFF ABOVE FINISH FLOOR
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
ALNMT ALIGNMENT
ALT ALTERNATE
ALUM ALUMINUM
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
APPROX APPROXIMATE
AR ANCHOR ROD
ARCH ARCHITECT or ARCHITECTURAL
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS
ASTM AMERICAN SOCIETY FOR TESTING &
MATERIALS
AWS AMERICAN WELDING SOCIETY
B/ BOTTOM OF
B/B BACK TO BACK
BF BOTH FACES
BLDG BUILDING
BM BEAM
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BASE PLATE
BRDG BRIDGING
BRG BEARING
BS BOTH SIDES
BTWN BETWEEN
C TO C CENTER TO CENTER
C/C CENTER TO CENTER
CANT CANTILEVER
CF CUBIC FEET
CFRP CARBON-FIBER-REINFORCED POLYMER
CHFR CHAMFER
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CY CUBIC YARD
D DEPTH
db REINFORCING BAR DIAMETER
DBA DEFORMED BAR ANCHOR
DBL DOUBLE
DEG DEGREE
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DL DEAD LOAD
DN DOWN
DTL DETAIL
DWG(S) DRAWING(S)
DWLS DOWELS
(E) EXISTING
EA EACH
EE EACH END
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELECT ELECTRIC or ELECTRICAL
ELEV ELEVATION
EMBED EMBEDMENT
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
ES EACH SIDE
ETC ETCETERA
EW EACH WAY
EXIST EXISTING
EXP JT EXPANSION JOINT
EXT EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FIN FINISH or FINISHED
FLG FLANGE
FLR FLOOR
FOB FACE OF BUILDING
FOW FACE OF WALL
FP FIRE PROTECTION
FT FOOT or FEET
FTG FOOTING
GA GAGE or GAUGE
GALV GALVANIZED
GACB GRANULAR AGGREGATE CAPILLARY BREAK
GC GENERAL CONTRACTOR
GR GRADE
H HIGH
HI HIGH BEAM
HGR HANGER
HK HOOK
HORZ HORIZONTAL
HP HIGH POINT
HPC HIGH PERFORMANCE COATING
HS HIGH STRENGTH
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR
CONDITIONING
ID INSIDE DIAMETER
IF INSIDE FACE
IN INCH
INCL INCLUDED
INFO INFORMATION
INT INTERIOR
INV INVERT
JF JOINT FILLER
JST JOIST
JT JOINT
K KIPS (1000 POUNDS)
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
L LENGTH
LB(S) POUND(S)
Ld REINF BAR DEVELOPMENT LENGTH
LE LEFT END
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LO LOW BEAM
LP LOW POINT
LTWT LIGHT WEIGHT
MANUF MANUFACTURE(R)
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEP MECH, ELECT AND PLUMB
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MTL METAL
N NORTH
(N) NEW
NLWT NORMAL WEIGHT
NOM NOMINAL
No. or # NUMBER
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
OPP OPPOSITE or OPPOSITE HAND
PEN PENETRATION
PJF PREFABRICATED JOINT FILLER
PJP PARTIAL JOINT PENETRATION
PLUMB PLUMBING
PROJ PROJECTION
PS PRESTRESSED
PSF POUND PER SQUARE FOOT
PSI POUND PER SQUARE INCH
R RISER or RADIUS
RAD RADIUS
RE RIGHT END
REBAR REINFORCING STEEL BARS
REF REFERENCE
REINF REINFORCEMENT or REINFORCING
REV REVISION
RFI REQUEST FOR INFORMATION
SCHED SCHEDULE
SDI STEEL DECK INSTITUTE
SDL SUPERIMPOSED DEAD LOAD
SEC SECTION
SHT SHEET
SIM SIMILAR
SLV SLEEVE
SOG SLAB-ON-GRADE
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
STAG STAGGERED
STD STANDARD
STIF STIFFENER
STIR STIRRUPS
STL STEEL
STRUC STRUCTURAL
SUPP SUPPORT
SW SHEAR WALL
SYMM SYMMETRICAL or SYMMETRY
T TREAD
T/ TOP OF
TB THROUGH BOLT
T&B TOP AND BOTTOM
TEMP TEMPORARY
THK THICK or THICKNESS
THRU THROUGH
TMS THE MASONRY SOCIETY
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOL TOLERANCE
TOS TOP OF SLAB
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V VERTICAL
VERT VERTICAL
VR VAPOR RETARDER
VIF VERIFY IN FIELD
W WIDTH
W/ WITH
W/C WATER-CEMENTITIOUS MATL RATIO
W/O WITHOUT
WD WOOD
WP WATERPROOFING
WP WORK POINT
WS WATERSTOP
WT WEIGHT
WWR WELDED WIRE REINF
BP# STEEL BASE PLATE MARK
D#+# STEEL DECKING MARK
MW# MASONRY WALL MARK
ABBREVIATIONS
3 3
54 5 4
TYP
7' - 4"
3' - 0" TYP BUILDING CORNER
T/ CONC
SLAB EL
T/ ROOF
TY
2'
- 6
EFFECTIVE AREA (SF)
SECTION ZONE 10 20 50 ≥ 100
FLAT ROOF 1 +16 / -55 +16 / -50 +16 / -47 +16 / -43
2 +16 / -72 +16 / -68 +16 / -61 +16 / -57 3 +16 / -98 +16 / -89 +16 / -77 +16 / -68
WALLS 4 +35 / -37 +33 / -36 +31 / -34 +29 / -32
5 +35 / -46 +33 / -43 +31 / -39 +29 / -36
TABLE AND DIAGRAM NOTES:
1. FOR THE CLADDING FASTENERS, THE EFFECTIVE WIND AREA MUST NOT BE GREATER THAN THE AREA
THAT IS TRIBUTARY TO AN INDIVIDUAL FASTENER.
2. WIND PRESSURE MAGNITUDES ARE FACTORED/ULTIMATE (LRFD) VALUES. MULTIPLY TABULATED VALUES
BY 0.6 TO OBTAIN SERVICE LEVEL (ASD) PRESSURE MAGNITUDES.
3. WIND PRESSURES ARE THE GROSS WIND PRESSURES FOR COMPONENTS AND CLADDING (SUM OF THE INTERNAL AND EXTERNAL PRESSURES) APPLIED NORMAL TO THE CLADDING SURFACE. THE MAGNITUDES
DO NOT INCLUDE COMPONENT SELF WEIGHTS.
4. POSITIVE VALUES INDICATE PRESSURE TOWARDS THE SURFACE AND NEGATIVE VALUES INDICATE
PRESSURE AWAY FROM THE SURFACE.
BUILDING COMPONENTS AND CLADDING PRESSURES (PSF)
ONE-WAY DECK
SPAN
DIRECTION
F1
X2 [X
'-X X"
T/CONC FOOTING EL
CONC FOOTING MARK
SLAB ON GRADE
SLAB
EXTENTS
DX
LEGEND
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
-A
BR
EV
IA
S, L
EG
, A
AD
D_S-002
TE
RS
TO
W N M
AR
YL
13134103
AB
RE
VI
AT
IO
N S, L
EG
EN
D, A
AD
GR
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
PE-1
PE-B
PE-2
PE-A
0"
28' - 0"
A1 D_S-101
B2
SOG6
0' - 0"
CJ
CJ
MW8
MW8
x2 [-2
WF1x2 [-2' - 0"] x2 [-2
WF1x2 [-2' - 0"]
B1
8" 8"
8" 8"
7 7
K3
D1.5SL
OP
DO
EOD 8"
EQ EQ EQ EQ EQ EQ
T/ CONC SLAB EL
T/ WALL LP
11' - 4"
PE-B PE-A
T/WALL HP
13' - 0 1/4"
20' - 0"
7'
- 4
2' - 0" 6' - 4"
2' - 8" 3' - 0"
MIN 8"
PE-BPE-A
2' - 0" 2' - 0" MIN 8"
FOR SEE
CONCRETE SLAB-ON-GRADE SCHEDULE
MASONRY WALL SCHEDULE
WALL FOOTING SCHEDULE
/A1 D_S-501 /A1 D_S-502 /A2 D_S-501
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
:1
-1
TR
U
TU
LA
LE
VA
SE
TE
RS
TO
W N M
AR
YL
13134104
ST
RU
TU
RA
L
PL
AN
S, E
LE
VA
TI
O N S, A
TI
O
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
1/8" = 1'-0"C1 FOUNDATION PLAN
1/8" = 1'-0"C2 ROOF FRAMING PLAN
GENERAL SHEET NOTES
1. ELEVATIONS SHOWN THUS [X' - X"]. REFER TO LEGEND SHEET ON B_S-002
2. INSIDE FACE OF LOAD BEARING WALLS ARE ALIGNED WITH GRID UON
3. COORD PENETRATIONS THRU SOG AND EQUIP PADS W/ MEP
# KEY NOTES
1/8" = 1'-0"B2 EAST ELEVATION
1/8" = 1'-0"B1 WEST ELEVATION
1 CJ = SAW CUT CONTRACTION JOINT, TYP
2 INTERIOR EQUIPMENT PAD. REFER TO MEP FOR LOCATION AND EXTENTS
3 CONCRETE RAKE BEAM
4 8" HIGH BOND BEAM WITH (2) #5 CONT AROUND PERIMETER
5 JOIST BRIDGING SHOWN FOR COORD ONLY, FINAL DESIGN AND LOCATION
BY JOIST SUPPLIER
6 1/2" COMPRESSIBLE FOAM BETWEEN EQUIPMENT PAD AND CMU WALL
7 CMU CONTROL JOINT
1/8" = 1'-0"A1 BUILDING SECTION
GRAPHIC SCALE 1/8" = 1'-0"
24'4' 8' 16'
1 1/2" DEEP SAWCUT JOINT. FILL
WITH SEMIRIGID JOINT FILLER
SEE SOG SCHED FOR SLAB REINF
3/4" DIA x 0'-10" LONG SMOOTH
DOWEL @ 12" OC. LIGHTLY OIL
FULL LENGTH OF DOWEL.
CONTRACTION JOINT
CONSTRUCTION JOINT
4" DRAINAGE COURSE SE
PL
SL
HK
VAPOR RETARDER
4" DRAINAGE COURSE BASE
VAPOR RETARDER
SEE SOG SCHED
HI
CK
NE
SS
T/SLAB
PROVIDE 1/4" WIDE x 1" DEEP TOOLED
SLOT. FILL WITH SEMIRIGID JOINT
FILLER T/ SLAB EL
SEE PLAN
T/ SLAB EL
NOTE:
1. PLATE DOWELS OF EQUAL OR BETTER PERFORMANCE ARE PERMITTED
IN LIEU OF ROUND DOWELS.
2"
LR
MARK THICKNESS
(IN)
REINF
EACH WAY
TOP COVER
(IN)
SOG6 6 WWR 6x6 W5.5/W5.5 2
SLAB-ON-GRADE SCHEDULE
1. COORDINATE PAD LOCATIONS AND SIZE WITH ELECTRICAL & MECHANICAL
DRAWINGS AND EQUIP MANUFACTURER'S RECOMMENDATIONS
ROUGHEN TO 1/4" AMPLITUDE
& APPLY BONDING AGENT
ADHESIVE ANCHORS, REFER TO
EQUIP SHOP DRAWINGS FOR TYPE,
SIZE, PROJECTION AND LOCATION.
MIN 3" EMBEDMENT INTO SLAB.
#3 @ 12" OC
MIN
6"
SEE NOTE 1
3/4" CHAMFER, TYPTY
1 1 /2"
WALL FOOTING SCHEDULE
SCHEDULED
WALL FOOTING
T/WALL FTG EL
REINF "L"
3"
FOOTING
MARK
(3) #4WF1x2
"M"
"L"THICK
1'-0"
WIDTH
2'-0"
FOOTING SIZE
SC
HE
REINF "M"SEE SCHEDULE
DOWELS TO MATCH CMU
VERTICAL REINF SIZE AND
SPACING
#4@8
CMU WALL
GROUT SOLID
BELOW GRADE AND
8" ABOVE GRADE
SEE ARCH
EQ EQ
ISOLATION JOINT
2" CLR(2) #3 x 3'-0" DIAGONAL
TYP EA CORNER
SLAB OPENING
1. TYPICAL SLAB REINFORCING NOT SHOWN.
2. DETAIL ALSO APPLIES TO CIRCULAR OPENINGS. ORIENT
DIAGONAL BARS 45 DEG FROM TYPICAL REINFORCING FOR
CIRCULAR OPENINGS.
ID
TH
DI
OP
NG
>1
9"
SLEEVE
DIA D" OF
SLEEVE
DIA D" OF
9"
MI
N4"
N6"
MIN
NO
3'
- 0
SLEEVE, 1" MIN CLR
AROUND PIPES,
COUNDUITS, ETC
CMU STEM WALL
PIPE THRU WALL
EXTEND FTG
AROUND SLEEVE
WALL FTG
1. FOR PIPES 3'-0" OR LESS BELOW BOTTOM OF FOOTING, PROVIDE SLEEVE AND CONCRETE AS SHOWN
2. FOR PIPES BETWEEN 3'-0" AND 5'-0" BELOW BOTTOM OF FOOTING, STEP FOOTING SO THAT THE
BOTTOM OF SLEEVE IS 3'-0" MAX FROM BOTTOM OF FOOTING AS SHOWN ABOVE
3. FOR PIPES 5'-0" OR MORE BELOW BOTTOM OF FOOTING, SLEEVES AND FOOTING EXTENSIONS ARE NOT
REQUIRED
SEALANT AND BACKER ROD
CONC SLAB-ON-GRADE
1/2" EXP JOINT FILLER
CLR
EDGE OF SLAB
ISOLATION JOINT
1' -
45.00°
(1) #4 RE-ENTRANT
CORNER, MIDDLE OF
SLAB EACH SIDE
1' - 0"
CONCRETE SLAB-ON-GRADE
(1) #4 CONT
3'
STD 90 DEG HOOK
4" CMU GROUT
SOLID BELOW
GRADE
EXTERIOR
PAVEMENT, SEE CIVIL
#4
" O
(1) #4 CONT
#4 @ 12" OC
1/2" PJF
CONT WALL
FOOTING SEE
PLAN
8"
SOG SEE PLAN
PLAN SECTION
RADIUS
2' - 0"
FLOOR DRAIN FLANGE
RA
1"
EP
IO
1. SEE ARCH, MECH, AND PLUMBING FOR DRAIN SIZE, TYPE, AND LOCATION.
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
-5
-T
YP
IC
ET
AI
LS
D_S-501
TE
RS
TO
W N M
AR
YL
13134105
PI
C
AL
DE
TA
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
NTSB1 SLAB-ON-GRADE JOINT DETAILS
NTSA1 SLAB-ON-GRADE SCHEDULE
NTSB2 INTERIOR EQUIPMENT PAD DETAIL
NTSA2 WALL FOOTING DETAIL AND SCHEDULE
NTSA3 SOG PENETRATION
NTSB4 FOOTING PIPE PENETRATION
NTSB3 CONCRETE SLAB ISOLATION JOINT
NTSA4 SLAB REINF AT DOOR
NTSC1 SLAB-ON-GRADE FLOOR DRAIN
MARK NOMINAL
THICKNESS (IN) REINF VERTICAL REMARKS
MW8 8 #4@32" OC CMU WALL FULLY GROUTED BELOW GRADE
MASONRY WALL SCHEDULE
GROUT CELLS
1/4" THICK GALV STEEL
STRAP @ 4'-0" OC VERT
2" 2"2' - 0"
1. VERTICAL REINF NOT SHOWN.
BOND BEAM REINF
SEE WALL SECTIONS
& MASONRY NOTES
CORNER BARS &
DOWELS TO
MATCH
BOND BEAM REINF
1. VERTICAL REINF NOT SHOWN.
LAP SPLICE
TENSION
ST
1'-
VERT BAR EACH SIDE OF CONTROL JOINT,
FULL HEIGHT OF WALL, MATCH SIZE OF TYP
WALL REINF
SEAL W/ BACKER ROD &
SEALANT, BOTH SIDES OF
WALL
STOP JOINT REINFORCEMENT AT CONTROL
JOINT
CONTROL JOINT
CMU WALL, SEE SCHED FOR REINF
1/8 2
T/ WALL
SEE EL
MIN 4" JOIST BEARING
STEEL JOIST,
SEE PLANCONCRETE RAKE BEAM
1/4" SEE PLAN 7 5/8"
2 1 /4"
1 1/2" 1 1/2"
PL 3/8x6x0'-9" W/ (2) 1/2" DIA x 6"
LONG HEADED STUDS. GALV AT
EXTERIOR WALLS
CONT BENT PL
1/4"x3"x0'-6" LLV
3" 3 1
7 5/8" SEE PLAN 1/4"
1'
CL
1 1
ROOF DECK
CONC RAKE BEAM
CMU REINF SEE SCHD
LAP SPLICE AS REQUIRED
TERMINATE END W/ STD HOOK
(2) #4 BARS
OPEN
GROUT CELLS SOLID
WHEN H > 4'-0" PROVIDE ADDL 1 #5 VERT EA SIDE OF
OPENING EXTEND BAR FROM 16" BELOW OPENING TO BOT OF
LINTEL
LINTEL, SEE
MAS NOTES
PROVIDE 1/2 OF THE INTERRUPTED VERT REINF FULL
HEIGHT OF WALL EA SIDE OF THE OPENING, 1 #5 MINIMUM
GROUT SOLID UNDER
OPENING AND WHEN W >
24" PROVIDE A BOND BEAM
W/ 2 #5 BELOW OPENING,
EXTEND BARS 24" PAST
OPENING
3/4"
LINTEL SEE MAS NOTES
SEE ARCH
CMU WALL SEE PLAN
14 GA CLOSURE PL
T/ WALL
SEE EL
SEE PLAN 7 5/8"
1 1/2" 1 1/2"
PL 3/8x6x0'-9" W/ (2) 1/2" DIA x 6" LONG
HEADED STUDS @ 32" OC MAX GALV AT
EXTERIOR WALLS, FASTEN DECK TO EACH
PLATE W/ (2) 5/8" DIA PUDDLE WELDS
CMU WALL, SEE SCHED FOR REINF
CONCRETE RAKE BEAM
ROOF DECK
SEALANT
PIPE/CONDUIT
PIPE SLEEVE
3/16" ANCHOR RING PLATE
INVERT EL
SEE MEP
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
-T
YP
IC
D_S-502
TE
RS
TO
W N M
AR
YL
13134106
PI
C
AL
DE
TA
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
NTSA1 MASONRY WALL SCHEDULE
NTSA2 MASONRY CORNER REINFORCING
NTSA4 MASONRY BOND BEAM CORNER DETAIL
NTSB1 MASONRY CONTROL JOINT DETAIL
NTSB2 JOIST BEARING ON WALL
NTSC4 RAKE BEAM
NTSC1 MASONRY WALL OPENING
NTSC2 LINTEL DETAIL
NTSB4 DECK BEARING ON WALL
NTSC3 PIPE SLEEVE THRU CME WALL
D_S-001 - GENERAL NOTES
D_S-002 - ABBREVIATIONS, LEGEND, AND LOAD DIAGRAM
D_S-101 - STRUCTURAL PLANS, ELEVATIONS, AND SECTIONS
D_S-501 - TYPICAL DETAILS
D_S-502 - TYPICAL DETAILS
2021-04-14T13:08:22-0400
Matthew T Bretthauer
I am signing to certify the authenticity of this document.
2021-04-14T13:08:46-0400
Matthew T Bretthauer
I am signing to certify the authenticity of this document.
2021-04-14T13:08:46-0400
Matthew T Bretthauer
I am signing to certify the authenticity of this document.
2021-04-14T13:08:46-0400
Matthew T Bretthauer
I am signing to certify the authenticity of this document.
2021-04-14T13:08:46-0400
Matthew T Bretthauer
I am signing to certify the authenticity of this document.
GENERAL SYMBOLS
MATCH LINE
KEYED NOTE
DOOR TAG
PARTITION TYPE TAG
(FIRST DIGIT INDICATES HOURLY FIRE RATING)
ELEVATION TARGET
NORTH ARROW
REVISION CLOUD
REVISION DESIGNATION TAG
WINDOW / LOUVER TYPE TAG
COLUMN REFERENCE
BREAK LINE
INDICATES PLAN NORTH
INTERIOR ELEVATION DESIGNATION
EXTERIOR ELEVATION DESIGNATION
SECTION / DETAIL DESIGNATION
DETAIL DESIGNATION
DRAWING /DETAIL LOCATION DESIGNATION
DRAWING/DETAIL TITLE
DRAWING NUMBER DESIGNATION
WHERE FIRST REFERENCED
DRAWING/DETAIL LIMITS
DRAWING / DETAIL LOCATION
DESIGNATION
DRAWING NUMBER DESIGNATION
WHERE FIRST REFERENCED
DRAWING / DETAIL LOCATION DESIGNATION
DRAWING NUMBER DESIGNATION WHERE SHOWN
DRAWING/DETAIL LOCATION DESIGNATION
DRAWING/DETAIL LOCATION DESIGNATION
DRAWING SCALE
ROOM TAG
GLASS TAGG1
A-100
A-100
A-200
A1A-400
W1
1A
MATCH LINE
A1 / A-101
DRAWING DESIGNATION
ROOM NUMBER
ROOM NAME
ELEMENT ELEVATED
EL:XX' - XX"
INDICATES TRUE NORTH
GENERAL ABBREVIATIONS
ABA ARCHITECTURAL BARRIERS ACT
ABI ALTERNATE BID ITEM
ACI AMERICAN CONCRETE INSTITUTE
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
ALUM ALUMINUM
AL/GL ALUMINUM GLASS DOOR
APC ACOUSTIC PANEL CEILING
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING
ENGINEERS
ASTM AMERICAN SOCIETY OF TESTING AND
MATERIALS
AV AUDIO VISUAL
AWP ACOUSTIC WALL PANEL
BD BOARD
BLDG BUILDING
BM BEAM
BOT BOTTOM
CFCI CONTRACTOR FURNISHED, CONTRACTOR
INSTALLED
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COR CONTRACTING OFFICER
CPT CARPET TILE
DIA DIAMETER
DWG DRAWING
E EAST
EA EACH
EJ EXPANSION JOINT
EL REFERENCE ELEVATION
ELEC ELECTRIC OR ELECTRICAL
EO EDGE OF
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXPAN EXPANSION
EXT EXTERIOR
EXTG EXISTING
FCO FLOOR CLEAN OUT
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FURNITURE, FIXTURES AND EQUIPMENT
FIN FINISH
FLR FLOOR
FM FACTORY MANUAL
FO FACE OF
GA GAGE OR GAUGE
GALV GALVANIZED
GFGI GOVERNMENT FURNISHED,
GOVERNMENT INSTALLED
GFCI GOVERNMENT FURNISHED,
CONTRACTOR INSTALLED
GL GLASS
GWB GYPSUM WALL BOARD
GYP GYPSUM
HD HEAD
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HM HOLLOW METAL
HT HEIGHT
HORIZ HORIZONTAL
HVAC HEATING, VENTILATION AND AIR CONDITIONING
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
IT INFORMATION TECHNOLOGY
JAN JANITOR
JT JOINT
LAM LAMINATE
LVT LUXURY VINYL TILE
MAINT MAINTENANCE
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL AND PLUMBING
MET METAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
N NORTH
N/A NOT APPLICABLE
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRIC MANUFACTURERS
ASSOCIATION
NGB NATIONAL GUARD BUREAU
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NOM NOMINAL
EQ EQUAL
OA OVERALL
OC ON CENTER
OFD OVERFLOW DRAIN
OH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
PART PARTITION
PH PHASE
PLAM PLASTIC LAMINATE
PLAS PLASTIC OR PLASTER
PLBG PLUMBING
PLYWD PLYWOOD
PREFAB PREFABRICATED
PRESS PRESSURE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PTD PAINTED
PVC POLYVINYL CHLORIDE
QT QUARRY TILE
R RISER
RAF RAISED ACCESS FLOOR
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REBAR REINFORCED STEEL BAR
REF REFERENCE
REQ'D REQUIRED
RM ROOM
RO ROUGH OPENING
SCHED SCHEDULE
SCW SOLID CORE WOOD
SF SQUARE FOOT
SHT SHEET
SIM SIMILAR
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOCIATION
SPEC SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
T TREAD
TC TOP OF COPING
TELECOM TELECOMMUNICATIONS
THK THICK OR THICKNESS
TOC TOP OF CONCRETE
TBD TO BE DETERMINED
TCNA TILE COUNCIL OF NORTH AMERICA
TOS TOP OF SLAB
TPO THERMOPLASTIC POLYOLEFIN
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
V VOLTS
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
WD WOOD
WP WATERPROOFING
WR WATER RESISTANT
WWF WELDED WIRE FABRIC
YD YARDS
GENERAL NOTES
1. IF THE CONTRACTOR DISCOVERS A CONDITION WHICH CONFLICTS WITH THE
DRAWINGS AND/OR SPECIFICATION, OR IF THE CONTRACTOR DISCOVERS AN UNCLEAR
OR MISLEADING DIRECTIVE GIVEN IN THE DRAWINGS OR SPECIFICATIONS, THE
CONTRACTOR MUST BRING THE ISSUE IMMEDIATELY TO THE ATTENTION OF THE
CONTRACTING OFFICER (COR).
2. DO NOT SCALE THE DRAWINGS - FOLLOW WRITTEN DIMENSIONS ONLY.
3. "MINIMUM" AS USED IN THESE DOCUMENTS MUST MEAN THAT THE CONDITION IS
SLIGHTLY ADJUSTABLE BUT MAY NOT VARY TO A DIMENSION OR QUALITY LESSER THAN
THAT INDICATED.
4. "MAXIMUM" AS USED IN THESE DOCUMENTS MUST MEAN THAT THE CONDITION IS
SLIGHTLY ADJUSTABLE BUT MAY NOT VARY TO A DIMENSION OR QUALITY GREATER
THAN THAT INDICATED.
5. "TYPICAL" AS USED IN THESE DOCUMENTS MUST MEAN THAT THE CONDITION OR
DIMENSION IS THE SAME OR REPRESENTATIVE FOR SIMILAR CONDITIONS
THROUGHOUT.
6. "CLEAR" AS USED IN THESE DOCUMENTS MUST MEAN THAT THE DIMENSION IS NOT
ADJUSTABLE WITHOUT THE APPROVAL OF THE CONTRACTING OFFICER. CLEAR
DIMENSIONS ARE TYPICALLY TO FINISHED FACE.
7. "ALIGN" AS USED IN THESE DOCUMENTS MUST MEAN TO ACCURATELY LOCATE THE
FINISHED FACES IN THE SAME PLANE.
8. FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO FABRICATION AND/OR
CONSTRUCTION.
9. WORK INDICATED ON THE DRAWINGS IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR UNLESS OTHERWISE NOTED.
10. CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS AND SEQUENCE OF
CONSTRUCTION. THE CONTRACTOR MUST SOLELY AND COMPLETELY BE RESPONSIBLE
FOR CONDITIONS OF THE PROJECT ON WHICH THE WORK IS PERFORMED AND FOR THE
SAFETY OF PERSONS AND/OR PROPERTY DURING THE PERFORMANCE OF THE
CONTRACT.
11. KEYED NOTES LISTED ON DRAWINGS REFER ONLY TO THOSE KEYED NOTE SYMBOLS
ASSOCIATED WITH THE PARTICULAR DRAWING WHERE THE KEYED NOTES ARE LISTED.
12. PLUMBING, MECHANICAL, ELECTRICAL AND FIRE PROTECTION SUBCONTRACTORS MUST
COORDINATE WITH GENERAL CONTRACTOR LOCATIONS OF REQUIRED ACCESS PANELS
FOR GENERAL CONTRACTOR TO PROVIDE IN THE BUILDING.
13. EXPOSED STEEL MUST BE PAINTED UNLESS OTHERWISE NOTED.
14. THERE ARE NO ASBESTOS CONTAINING MATERIALS SPECIFIED AND THEY MUST NOT BE
USED ON THIS PROJECT.
15. HAUL ROUTE TO THE SITE MUST BE COORDINATED WITH THE COR.
16. ACCESS TO THE WORK AREA MUST BE REGULATED BY THE OWNER.
17. COORDINATE THE WORK OF TRADES AND CHECK DIMENSIONS. DISCREPANCIES MUST
BE CALLED TO THE ATTENTION OF THE COR AND MUST BE RESOLVED BEFORE
PROCEEDING WITH THE WORK.
18. REFER TO SURVEYOR DRAWINGS THAT HAVE BENCH MARK ELEVATIONS FOR VERTICAL
ELEVATIONS REFERENCED.
19. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE
CONDITIONS ARE NOT SPECIFICALLY INDICATED, SIMILAR DETAILS MUST BE USED
SUBJECT TO REVIEW BY THE ARCHITECT / ENGINEER.
20. REFER TO FIRE SUPPRESSION AND ALARM DRAWINGS AND ELECTRICAL DRAWINGS FOR
LOCATIONS OF FIRE ALARM HORNS/STROBES, EXIT SIGNS, AND EMERGENCY LIGHTING.
23. EXPOSED CONCRETE FLOORS MUST BE PROTECTED DURING CONSTRUCTION AND MUST
BE FREE OF CONSTRUCTION MARKERS, STAINS, PAINTS, OIL, OR OTHER DEFECTS.
PATCH, IF REQUIRED, PRIOR TO HARDENING AND SEALING.
24. CONFINE EQUIPMENT, STORAGE OF MATERIALS, AND OPERATIONS OF WORKERS TO
LIMITS INDICATED.
25. OWNER HAS NO RESPONSIBILITY FOR DAMAGE OR LOSS DUE TO STORING OF
MATERIALS AND EQUIPMENT.
26. TRUCKS HAULING DEBRIS FROM THE PROJECT SITE OR MATERIAL TO THE PROJECT
MUST BE EQUIPPED WITH THE MEANS TO COVER LOADS AND WITH WATERPROOF
TAILGATES WHICH SHUT TIGHTLY AND DO NOT PERMIT THE DEBRIS TO SPILL FROM THE
TAILGATE AREA. TRUCK BEDS MUST BE SWEPT CLEAN AT THE TAILGATE BEFORE
LEAVING FROM THE WORK AREA. SIDEBOARDS MUST BE KEPT IN GOOD REPAIR. UNDER
NO CIRCUMSTANCES WILL TRUCKS BE PERMITTED TO LOAD OR UNLOAD GREATER THAN
THE LEGAL LIMIT OR HIGHER THAN THE SIDEBOARDS.
27. OWNER WILL MAKE USE OF THE AREAS IN AND SURROUNDING THE CONSTRUCTION
AREAS. EVERY EFFORT MUST BE MADE TO MINIMIZE THE DISTURBANCE TO
EMPLOYEES, PATRONS, AND TENANTS.
28. MANUFACTURER'S NAME AND/OR MODEL NUMBERS ARE BEING UTILIZED FOR BASIS OF
DESIGN ONLY. THE SPECIFICATION OUTLINES THE SPECIFIC CRITERIA FOR THE
EQUIPMENT OR MATERIAL AND IS NON-PROPRIETARY.
29. MANUFACTURED MATERIALS, EQUIPMENT, MUST BE INSTALLED IN ACCORDANCE WITH
THE MANUFACTURER'S RECOMMENDATIONS, INSTRUCTIONS, AND ABA/ADA
REQUIREMENTS UNLESS OTHERWISE NOTED.
30. PROVIDE A RED LINED "RECORD" CONSTRUCTION DOCUMENT SET AT THE SITE. THE
OWNER RESERVES THE RIGHT TO REVIEW THESE DOCUMENTS ON A DAILY BASIS.
31. ITEMS INDICATED ON THE DRAWINGS AS "GFGI" MEANS GOVERNMENT FURNISHED AND
GOVERNMENT INSTALLED. COORDINATE WITH THE GOVERNMENT FOR THE REQUIRED
POWER, PLUMBING, AND OTHER REQUIRED UTILITIES AS APPLICABLE.
32. ITEMS INDICATED ON THE DRAWINGS AS "GFCI" MEANS GOVERNMENT FURNISHED AND
CONTRACTOR INSTALLED. COORDINATE WITH SCOPE OF WORK.
33. SUSPENDED ITEMS OF THE WORK EXCEEDING 31 POUNDS IN WEIGHT (EXCLUDING
DISTRIBUTED SYSTEMS SUCH AS PIPING NETWORKS) MUST BE ANCHORED TO RESIST A
HORIZONTAL LOAD 0.5 TIMES THE COMPONENT WEIGHT IN ACCORDANCE WITH UFC
4-010-01. THIS REQUIREMENT DOES NOT PRECLUDE REQUIREMENTS FOR SEISMIC
ANCHORAGE IN ACCORDANCE WITH ASCE 7-05 AND THE PROJECT SPECIFICATIONS. FOR
ADDITIONAL INFORMATION ON EQUIPMENT SUPPORT FRAMING REFERENCE
STRUCTURAL.
34. DO NOT PAINT BUILDING GROUNDING CABLES.
35. PROVIDE SURFICIAL TERMITE TREATMENT UNDER ENTIRE FOOTPRINT OF THE MSTC
BUILDING. CONDUITS AND PIPES PENETRATING THE SLAB ON GRADE MUST HAVE A
TERMITE SHIELD.
MATERIAL LEGEND
STEEL
THERMAL INSULATION (BATT)
THERMAL INSULATION (RIGID)
ACOUSTIC PANEL CEILING
WOOD ROUGH
CMU TYPE 1
WOOD BLOCKING, SHIM
PARTICLEBOARD/PLYWOOD
GLASS
METAL GRATING
SOLID SURFACE MATERIAL
GYPSUM BOARD
CONCRETE
EARTH
NUMBERING SYSTEM:
XX100
DISCIPLINE:
C - CIVIL
L - LANDSCAPE
A - ARCHITECTURE
M - MECHANICAL
E - ELECTRICAL
P - PLUMBING
S - STRUCTURAL
K - FOOD SERVICE
DISCIPLINE MODIFIER
SHEET NUMBER WITHIN
SERIES
REFER TO AEC CAD
STANDARDS FOR PROPER
SHEET NUMBERING
A-123
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
:3
_A
BB
VI
IO
D_A-001
TE
RS
TO
W N M
AR
YL
13134107
PS AD WS
ER
S, A B B
RE
VI
AT
IO
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
LV
VS
VS
FM
FPC
J
J J J J
D_A-201 C3
C1 D_A-301
B3
PUMP ROOM
10120
1' - 3 5/8" 1' - 3 5/8" 30' - 7 1/4"
- 3
5/
6'
7 1
1' - 3 5/8" 1' - 3 5/8"
0"1"
KEYNOTES#
A. EXTERIOR DIMENSIONS ARE FROM CMU AND MASONRY OPENINGS.
DIMENSION STRINGS ON ENDS OF BUILDING ARE TO OUTSIDE FINISH
MATERIAL.
B. PARTITION / WALL MOUNTED EQUIPMENT NOT INDICATED ON THE
DRAWINGS MUST BE COORDINATED WITH THE COR PRIOR TO
INSTALLATION.
C. FOR RECESSES IN FLOOR SLAB, REFER TO STRUCTURAL.
D. NON-ARCHITECTURAL EQUIPMENT LOCATIONS INDICATED ON
ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. EQUIPMENT
LOCATIONS MUST BE COORDINATED WITH UTILITIES INDICATED ON CIVIL,
MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL, AND
EQUIPMENT DRAWINGS.
E. EXPOSED CMU VENEER AT CORNERS MUST BE SOLID BLOCK TO MAINTAIN
8" MODULE, WIDE EXPOSED SURFACES MATCHING INDICATED FINISH.
F. REFER TO PLUMBING, MECHANICAL, ELECTRICAL, FIRE SUPPRESSION,
FIRE ALARM AND TELECOMMUNICATION DRAWINGS FOR VENTS,
SPRINKLER HEADS, GRILLES, REGISTERS, DIFFUSERS, DUCTS, LIGHTS,
DETECTORS, ETC AND COORDINATE BETWEEN DISCIPLINES.
G. ROOF: HYDROSTATIC STANDING SEAM METAL ROOF. SLOPE AS
INDICATED ON ROOF PLAN.
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
:4
-P
D_A-101
TE
RS
TO
W N M
AR
YL
13134108
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
GRAPHIC SCALE 1/4" = 1'-0"
2' 4' 8' 12'
1/4" = 1'-0"C1 GROUND LEVEL PLAN
1/4" = 1'-0"C3 ROOF PLAN
1/4" = 1'-0"A1 REFLECTED CEILING PLAN
1 JOIST. REFER TO STRUCTURAL
2 MECHANICAL EQUIPMENT, TYP. REFER TO MECHANICAL
3 STANDING SEAM METAL ROOF, RP-1
4 8"W X 6"H METAL GUTTER
5 LIGHTNING PROTECTION, REFER TO ELECTRICAL
6 5" MTL DOWNSPOUTS, TYP
PE-1 PE-2
PE-B PE-A
LV-1
D_A-601
PE-1PE-2
11 11 11
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
-2
-E
TE
RS
TO
W N M
AR
YL
13134109
EL
AT
IO
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
1/4" = 1'-0"C3 SOUTH ELEVATION
1/4" = 1'-0"C1 EAST ELEVATION
1/4" = 1'-0"B3 NORTH ELEVATION
1/4" = 1'-0"B1 WEST ELEVATION
1 8"W X 6"H METAL GUTTER
2 4"X4"X16" NOM ARCHITECTURAL BLOCK AB-1
3 AIR INTAKE LOUVER/ VENT, TYP PT-1
4 EXHAUST LOUVER/ VENT, TYP REFER TO MECHANICAL
5 ROOF RIDGE
6 5" MTL DOWNSPOUTS, TYP
7 SPLASH BOX
8 STANDING SEAM METAL ROOF, RP-1
9 WALL PACK LIGHT. REFER ELECTRICAL DWGS
10 MANUAL TRANSFER SWITCH, REFER ELECTRICAL
11 CONTROL JOINT, TYP.
12 LIGHTNING PROTECTION, REFER TO ELECTRICAL
13 STANDING SEAM MTL ROOF
14 RIB-MOUNTED SNOW RETENTION
15 2-PART FASCIA, TYP
GRAPHIC SCALE 1/4" = 1'-0"
2' 4' 8' 12'
D_A-501
PE-1 PE-2
A4
B4
RI
A3
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
-3
-B
TE
RS
TO
W N M
AR
YL
13134110
IL
DI
L
SE
C
TI
O
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
3/8" = 1'-0"C1 BUILDING SECTION
3/8" = 1'-0"A1 BUILDING SECTION
1 STRUCTURAL STEEL JOIST, REFER TO STRUCTURAL
2 STANDING SEAM METAL ROOF, RP-1
3 LIGHTNING PROTECTION, REFER TO ELECTRICAL
4 MANUAL TRANSFER SWITCH, REFER ELECTRICAL
5 SPLASH BOX
6 5" MTL DOWNSPOUTS, TYP
7 2-PART FASCIA, TYP
GRAPHIC SCALE 3/8" = 1'-0"
8'2' 4'1'
SLOPE
MA
X3"
1 0 "
N.1"
22 1519
3 1
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
-W
TE
RS
TO
W N M
AR
YL
13134111
L
DE
TA
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
3" = 1'-0"A3 FOUNDATION
3" = 1'-0"C1 ROOF DRAIN
3" = 1'-0"C3 ROOF RAKE
3" = 1'-0"A1 ROOF FASCIA
1 8" CMU
2 CRUSHED STONE; SEE STRUCT DWGS
3 CONC SOG. SEE STRUCT DWGS
4 VAPOR BARRIER, LAP UP WALL
5 5" MTL DOWNSPOUTS, TYP
6 8"W X 6"H METAL GUTTER
7 1" X 1" CONT. DRIP ANGLE
8 GUTTER CLEAT WITH 3/4" OPEN HEM TO HANG GUTTER
9 1/8" X 1 1/2" GUTTER STRAP @30" O/C.
10 ROOF UNDERLAYMENT WITH ICE & WATER SHIELD
11 4"X4"X16" NOM ARCHITECTURAL BLOCK AB-1
12 6" RIGID INSULATION
13 STRUCTURAL STEEL JOIST, REFER TO STRUCTURAL
14 5/8" ROOF COVER BOARD / SHEATHING
15 STANDING SEAM METAL ROOF, RP-1
16 STANDING SEAM KNEE/RIB CLOSURE
17 TURNED-DOWN STANDING SEAM PANEL, RF-1
18 METAL DECK, REFER TO STRUCTURAL
19 AIR BARRIER / VAPOR RETARDER
20 CONT. CLEAT
21 2" RIGID INSULATION
22 ICE AND WATER SHIELD UNDERLAYMENT
23 2-PART FASCIA: FORMED SHEET METAL MTL-1 OVER 2
LAYERS OF BLOCKING. OUTER LAYER OF BLOCKING DEEP
ENOUGH TO ACCOMMODATE GUTTER, INNER LAYER TO
OVERLAP BRICK 1" MIN
24 CONTINUOUS HOLD DOWN CLEAT
25 LIGHTNING PROTECTION, REFER TO ELECTRICAL
26 MORTAR NET
27 FOOTING
28 WATERPROOFING
29 DRAINAGE MAT
30 4" CMU
31 GROUT CAVITY
32 RIGID INSULATION R-15 MIN.
33 WEEP HOLES AT 24" AT OC
34 BRICK TIES AT 2'-0" OC
35 PREMOLDED JOINT FILLER, REFER TO STRUCTURAL
36 THROUGH WALL FLASHING
37 GABLE CLIP
38 FOAM INSERT
39 FORMED METAL COPING
40 4" RIGID INSULATION FOR 24"
41 SEALANT
42 METAL DECK FLUTE FOAM CLOSURE
43 MINERAL WOOL INSULATION, TYP
44 CONCRETE RAKE BEAM
45 8" CMU GROUTED
0 6" 1'
GRAPHIC SCALE 3" = 1'-0"
TYPE: F1
2" 2"
FE
CH
ED
UL
REFER TO
SCHEDULE
REFER
TO SCHEDULE
FE
CH
UL
3' - 0"
Sim
B4
Sim
LV-1
2 1/2" 10"
LOUVER SCHEDULE
NO. WIDTH HEIGHT HEAD ACCESSORIES
LV-1 3' - 0" 2' - 6" B4 / D_A-601
JAMB
A3 / D_A-601
SILL
A4 / D_A-601
1' - 0 1/2"
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
-6
TE
RS
TO
W N M
AR
YL
13134112
SC
ED
U
LE
S
AG
RA
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
NAVFAC_DOOR SCHEDULE
DOOR NO. TYPE
DOOR
FIRE
RATING
FRAME
HARDWARE COMMENTS:
SIZE
FINISH
UNDER
CUT TYPE MATERIAL
DETAILS
WIDTH HEIGHT
THICKNES
S HEAD JAMB
101 A 6' - 0" 7' - 0" 0' - 1 3/4" PAINT - NR F1 HM B1/D_A-601 B2/D_A-601 10.0 INSULATED DOOR, REFER TO VMF DOOR HARDWARE SET
1/2" = 1'-0"
DOOR AND FRAME TYPES
1" = 1'-0"A1 LOUVER ELEVATION
3" = 1'-0"A2 LOUVER JAMB DETAIL
3" = 1'-0"B4 LOUVER HEAD DETAIL
3" = 1'-0"A4 LOUVER SILL DETAIL
3" = 1'-0"C3 HEAD DETAIL
3" = 1'-0"C4 JAMB DETAIL
1 4"X4"X16" NOM ARCHITECTURAL BLOCK AB-1
2 BACKER ROD AND SEALANT
3 2" RIGID INSULATION
4 HM DOOR AND FRAME, TYP
5 AIR BARRIER / VAPOR RETARDER
6 BOND BEAM, REFER TO STRUCTURAL
7 EXTERIOR GRADE SHIM
8 LOUVER
9 8" CMU
10 NON-CURING BUTYL SEAL
11 LOUVER ATTACHMENT ANGLE AND FASTENER
12 LOUVER
13 METAL FLASHING
14 SILL PLATE
15 MORTAR MESH
16 WEEP VENT INSERTS AT 24" OC
17 STEEL ANGLE, REFER TO STRUCTURAL
18 4"X4"X16" NOM LIPPED ARCHITECTURAL BLOCK AB-1
19 THROUGH WALL FLASHING
20 METAL FLASHING CLOSURE
3" = 1'-0"B2 SILL DETAIL
0 6" 1'
GRAPHIC SCALE 3" = 1'-0"
0 2'
GRAPHIC SCALE 1" = 1'-0"
6" 1' 3'
GRAPHIC SCALE 1/2" = 1'-0"
1' 2' 4' 6'
D_A-001 - GENERAL NOTES, ABBREVIATIONS
D_A-101 - PLANS
D_A-201 - ELEVATIONS
D_A-301 - BUILDING AND WALL SECTIONS
D_A-501 - WALL DETAILS
D_A-601 - SCHEDULES AND DIAGRAMS
2021-04-14T11:24:41-0400
Peter Soukas
I am signing to certify the authenticity of this document.
2021-04-14T11:24:54-0400
Peter Soukas
I am signing to certify the authenticity of this document.
2021-04-14T11:24:54-0400
Peter Soukas
I am signing to certify the authenticity of this document.
2021-04-14T11:24:54-0400
Peter Soukas
I am signing to certify the authenticity of this document.
2021-04-14T11:24:55-0400
Peter Soukas
I am signing to certify the authenticity of this document.
2021-04-14T11:24:55-0400
Peter Soukas
I am signing to certify the authenticity of this document.
P A R
TM
E N T O F
TH
E
N A
V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A
ARLINGTON, VIRGINIA 22201
8:
_F
D_F-001
TE
RS
TO
W N M
AR
YL
13134113
BT JR BT
ER
ET
AS
H
IN
GT
O
H
IN
G
TO
N
N
AV
Y
YA
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING JURISDICTION
DN DOWN
EX EXISTING
FDC FIRE DEPARTMENT CONNECTION
FM FM GLOBAL
FP FIRE PROTECTION
GPM GALLONS PER MINUTE
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NO NORMALLY OPEN
RN RISER NIPPLE
SQ FT SQUARE FOOT
UL UNDERWRITERS LABORATORIES
COTR CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE
FIRE PUMP SYSTEM NOTES
THESE DOCUMENTS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN LAYOUT TO BE
UTILIZED AS GUIDANCE FOR THE PLANNING OF THE SYSTEM. PROVIDE COMPLETE
DOCUMENTS FOR REVIEW AND APPROVAL FROM THE ENGINEER OF RECORD AND THE
AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. INCLUDE IN THE SHOP
DRAWINGS AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY.
COORDINATE AND SEQUENCE THE WORK PRIOR TO FABRICATION AND INSTALLATION OF
EQUIPMENT. MAKE NECESSARY ACCOMMODATIONS TO MEET THE INTENT OF THE
DRAWINGS AND ENSURE A COORDINATED INSTALLATION.
PROVIDE PRODUCT INFORMATION, SHOP DRAWINGS, DOCUMENTS AND WARRANTIES FOR
MATERIALS AND SERVICES PROVIDED ON THIS PROJECT.
PERFORM INSTALLATION IN A NEAT AND PROFESSIONAL MANNER IN ACCORDANCE WITH
INDUSTRY STANDARD MATERIALS, TOOLS, AND METHODS.
COORDINATE MOUNTING HEIGHTS OF DEVICES ON FINISHED WALLS TO PROVIDE A NEAT
AND SYMMETRICAL APPEARANCE.
CLEAR ALL DEBRIS FROM THE AREA OF WORK AND LEAVE SITE IN CLEAN CONDITION.
CLEAN ALL EQUIPMENT ENCLOSURES, INSIDE AND OUTSIDE
CONTRACT DRAWINGS MUST BE USED WITH THE SPECIFICATIONS TO OBTAIN COMPLETE
CONSTRUCTION INFORMATION. COORDINATE ALL DRAWINGS AND SPECIFICATIONS PRIOR
TO COMMENCING WORK. QUESTIONS REGARDING DESIGN INTENT OR SYSTEM OPERATION
MUST BE PROMPTLY BROUGHT TO THE CONTRACTING OFFICER.
ANY CONFLICTS BETWEEN SPECIFICATIONS AND DRAWINGS MUST BE BROUGHT TO THE
GOVERNMENT'S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH ANY WORK EXCEPT AT
THEIR OWN RISK, UNTIL CLARIFICATIONS OF CONFLICTS ARE ISSUED TO THE CONTRACTOR
BY THE COTR OR HIS/HER AUTHORIZED REPRESENTATIVE.
AVOID ALL CONFLICTS WITH LIGHT FIXTURES, HVAC DIFFUSERS, GRILLS, DUCTS, CONDUIT
AND OTHER PIPING OR OTHER OBSTRUCTIONS ENCOUNTERED. COORDINATE ALL WORK
WITH FIELD CONDITIONS. PROMPTLY NOTIFY COTR PRIOR TO INITIATING WORK, IF ANY
MOUNTING LOCATIONS ARE OBSTRUCTED AND/OR IF ANY MOUNTING CONFLICTS OR
PROBLEMS ARE DISCOVERED.
INSTALL SPRINKLERS IN CENTER OF CEILING TILES. ALIGN SPRINKLERS SYMMETRICALLY
OR OTHERWISE ALIGNED ON CENTERLINES WITH OTHER SPRINKLERS AND WITH
CONSIDERATION TO ARCHITECTURAL FEATURES (SOFFITS, ETC.) WITHOUT VIOLATING
REFERENCED STANDARDS OR THIS SPECIFICATION.
DESIGN LAYOUT AND DRAWING BACKGROUNDS ARE FOR BIDDING PURPOSES ONLY AND
ARE NOT TO BE USED FOR CONSTRUCTION. DRAWING BACKGROUNDS MAY NOT MATCH
FIELD CONDITIONS. VERIFY ALL FIELD DIMENSIONS PRIOR TO FABRICATION/INSTALLATION
OF ANY EQUIPMENT.
CORE DRILL PENETRATIONS IN MASONRY WALLS AND FLOOR/CEILING SLABS. EXAMINE ALL
WALLS AND FLOORS FOR HIDDEN OBSTRUCTIONS PRIOR TO CORE DRILLING.
SEE ARCHITECTURAL DRAWINGS FOR ROOM FINISH SCHEDULE AND ROOM USE. SEE
ARCHITECTURAL, ELECTRICAL, MECHANICAL, AND TELECOMMUNICATIONS PLANS FOR THE
LOCATION OF ALL CEILING-MOUNTED DEVICES. FIELD VERIFY AND COORDINATE THE
LOCATIONS OF ALL SYSTEM COMPONENTS INCLUDING PIPING, ALARMS, DRAINS, TEST
POINTS, ETC. WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL
EQUIPMENT WITHIN THE BUILDING.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
FIRE SPRINKLER NOTES
COORDINATE ALL REQUIRED SYSTEMS TO THE SATISFACTION OF THE CONTRACTING
OFFICER AND AUTHORITY HAVING JURISDICTION. CORRECTION OF ANY DEFICIENCIES,
INCONSISTENCIES, OR POORLY COORDINATED INSTALLATIONS ARE THE RESPONSIBILITY
OF THE CONTRACTOR AT NO ADDITIONAL COST.
FINAL DESIGN REQUIREMENTS (DEVICE QUANTITY, SIZE, AND LOCATIONS) ARE THE SOLE
RESPONSIBILITY OF THE CONTRACTOR. DRAWINGS INDICATE MINIMUM REQUIREMENTS;
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND COORDINATING FINAL DESIGN
REQUIREMENTS WITH THESE CONSTRUCTION DOCUMENTS, SPECIFICATIONS, REFERENCE
DOCUMENTS, APPLICABLE CODES, AND FACILITY USER REQUIREMENTS.
ALL DRAIN PENETRATIONS THROUGH EXTERIOR WALL MUST BE NO GREATER THAN 2'-0"
ABOVE FINISHED GRADE.
INSTALL ALL VALVES, INCLUDING CONTROL AND TRIM VALVES, WITHIN 6'-0" AFF.
FIRE SUPPRESSION DESIGN CRITERIA:
A.
B.
C.
D.
CONNECT THE FIRE SUPPRESSION SYSTEM TO NEW FIRE PROTECTION
INFRASTRUCTURE. BASE HYDRAULIC CALCULATION ON THE DEDICATED SITE-WIDE
FIRE PUMP RATING. SEE SHEET D_F-101.
HYDRAULICALLY DESIGN ORDINARY HAZARD OCCUPANCY AREAS (OH) BASED ON A
MINIMUM 0.20 GPM/SF OVER THE HYDRAULICALLY MOST REMOTE 2,500 SF. MAXIMUM
SPRINKLER SPACING MUST NOT EXCEED 130 SF. INCLUDE A 250 GPM HOSE STREAM
ALLOWANCE IN THE HYDRAULIC DESIGN.
THE FIRE SUPPRESSION SYSTEM MUST BE DESIGNED AND INSTALLED BY A LICENSED /
CERTIFIED COMPANY WHERE EMPLOYEES ARE LICENSED / CERTIFIED TO INSTALL FIRE
PROTECTION EQUIPMENT IN THE STATE OF VIRGINIA.
ALL COMPONENTS AND ASSEMBLIES USED IN THIS FIRE PROTECTION SYSTEM MUST BE
SPECIFICALLY UL LISTED OR FM APPROVED FOR THEIR INTENDED USE.
FIRE ALARM NOTES
PROVIDE SYSTEM DESIGN AND INSTALLATION OF A NEW FULLY CODE COMPLIANT, SUPERVISED, ADDRESSABLE FIRE ALARM SYSTEM.
This is the start of the file's text. The full file is on GovTribe.