This is an architectural design document set for modular residential housing units at Yellowstone National Park, prepared by Stantec and marked as preliminary/not for construction. The document provides detailed construction plans for both 2-bedroom and 3-bedroom modular housing units, including standard and Americans with Disabilities Act (ABA) compliant versions, with design dates of June 12, 2026 and revisions through June 18, 2026.
The architectural specifications establish minimum design and construction requirements across multiple disciplines. Key specifications include: 2x6 exterior wall studs at 16-inch on-center spacing and 2x4 interior walls at 16-inch on-center with insulation meeting 2021 IECC standards; metal standing seam roofs with fiber cement siding; fiberglass windows with storm screens and decorative non-functional shutters; and 8-foot ceiling heights standard throughout. Water heaters must be 50-gallon minimum for 2-bedroom units and 66-gallon minimum for 3-bedroom units, with all plumbing conforming to 2021 Uniform Plumbing Code. Electrical systems require 2023 National Electric Code compliance with all interior LED lighting, exterior fully-shielded LED lighting limited to 2 foot-candles at 3,000K maximum, and compliance with NPS night sky protection guidelines. Fire suppression systems must comply with NFPA 13D standards for residential sprinkler systems, requiring NICET Level II minimum for installation, Level III for project oversight, and Level IV for design. All modular units must be reviewed, approved, and stamped by the manufacturer prior to fabrication and installation, with the contractor responsible for coordinating all work with applicable utility providers and obtaining required permits within ten days of receipt. ABA-compliant units include accessible kitchens, bathrooms, grab bars, and ramp requirements conforming to 2024 ABA standards.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
EV
IT
V
ER
SI
O
N
198433
/1
/2
:4
:0
P M
A u to d e sk
D o c s:
Y
E
LL
N
P S /0 a rc h b d r.
rv t
SHEET INDEX & CODE
INFORMATION
326141A000
06/12/2026
ARCHITECTURAL SHEET INDEX
NO. DRAWING NAME
GENERAL
A000 SHEET INDEX & CODE INFORMATION
ARCHITECTURAL
A005B 2BR ABA DOOR & WINDOW TYPES / SCHEDULES / DETAILS
A005C 3BR DOOR TYPES / SCHEDULES / DETAILS
A005D 3BR ABA DOOR TYPES / SCHEDULES / DETAILS
A006C 3BR WINDOW TYPES / SCHEDULES / DETAILS
A006D 3BR ABA WINDOW TYPES / SCHEDULES / DETAILS
A101A 2BR FLOOR & REFLECTED CEILING PLAN
A101B 2BR ABA FLOOR & REFLECTED CEILING PLAN
A101C 3BR FLOOR PLAN
A101D 3BR ABA FLOOR PLAN
A102C 3BR REFLECTED CEILING PLAN
A102D 3BR ABA REFLECTED CEILING PLAN
A200A 2BR ELEVATIONS
A200B 2BR ABA ELEVATIONS
A200C 3BR ELEVATIONS
A200D 3BR ABA ELEVATIONS
A610B 2BR ABA INTERIOR ELEVATIONS
A610C 3BR INTERIOR ELEVATIONS
A610D 3BR ABA INTERIOR ELEVATIONS
A901B 2BR ABA RENDERINGS
A901C 3BR RENDERINGS
A901D 3BR ABA RENDERINGS
PLUMBING
9. COMPLIANCE WITH IWUIC AND THE APPLICABLE FIRE-RESISTIVE
CONSTRUCTION REQUIREMENTS OF NPS REFERENCE MANUAL 58 ARE
REQUIRED.
8. PROVIDE PROPERLY SIZED WALLS TO ALLOW DRILLING & NOTCHING
COMPLIANCE PER R 602.6.
7. ALL CONCENTRATED FRAMING LOADS TO TRANSFER TO FOUNDATION.
6. BACKWATER VALVE MAY BE REQUIRED PER UPC 710.1. PLUMBER TO
VERIFY.
5. WATER HEATER TO BE 40 GAL FOR 2 BEDROOM & 60-80 FOR 3
BEDROOM
4. WATER HEATER SEISMIC STRAPS REQUIRED PER UPC 508.2.
3. WATER HEATER TP VALVE TO TERMINATE PER UPC 608.5 & 508.5 SEE
ALSO A.R.M.
2. FLOOR DRAINS REQUIRE TRAP SEAL PROTECTION PER UPC 1007.
1. FIREBLOCKING THROUGHOUT TO COMPLY WITH R 302.11.
CODE NOTES
*Minimum Requirements Above
Crawl Space Wall R-Value
15ci or 19 or 13&5ci
15ci or 19 or 13&5ci
Floor
30 or 19&7.5ci or
20ci
Wood-Framed Wall
30 or 20&5ci or 13&10ci or 0&20ci
30 or 20&5ci or 13&10ci or 0&20ci
Insulation Entirely Above Roof Deck
49 above ceiling & below deck
30ci or 38 above ceiling and below deck
Glazed Vertical Fenestration SHGC NR NR
Vertical Fenestration (U-factor)
0.3 *0.32 shall apply above 4,000 ft
0.28 *0.30 shall apply above 4,000 ft
2021 2024
Climate Zone 6B Requirements
Architectural Barriers Act
2024 International Wildland-Urban Interface Code
2024 International Fire Code
2017 ANSI 117.1
2024 International Energy Conservation Code
2024 International Fuel Gas Code
2024 International Mechanical Code
2023 National Electric Code
2021 Uniform Plumbing Code
2024 International Residential Code
2024 International Building Code
SITE CONDITIONS AND APPLICABLE CODES MAY VARY BY
JURISDICTION. IT IS THE RESPONSIBILITY OF THE CONTRACOTR AND
MANUFACTURER TO VERIFY ALL LOCAL REQUIREMENTS PRIOR T...
THESE DRAWINGS REPRESENT A CONFORMANCE SET AND ARE
INTENDED TO ILLUSTRATE DESIGN INTENT. ALL MODULAR UNITS
MUST BE REVIEWED, APPROVED, AND STAMPED BY THE MODULAR
UNIT MANUFACTURER PRIOR TO FABRICATION AND INSTALLATION.
APPLICABLE BUILDING CODES
ARCHITECTURAL SHEET INDEX
NO. DRAWING NAME
P101A 2BR PLUMBING PLAN
P101B 2BR ABA PLUMBING PLAN
P101C 3BR PLUMBING PLAN
P101D 3BR ABA PLUMBING PLAN
ELECTRICAL
E101A 2BR ELECTRICAL PLAN
E101B 2BR ABA ELECTRICAL PLAN
E101C 3BR ELECTRICAL PLAN
E101D 3BR ABA ELECTRICAL PLAN
ARCHITECTURAL
A001 STANDARD ABBREVIATIONS, SYMBOLS, & NOTES
ARCHITECTURAL
A002 TYPICAL MOUNTING HEIGHTS
ARCHITECTURAL
A003 ASSEMBLY
ARCHITECTURAL
A005A 2BR DOOR & WINDOW TYPES / SCHEDULES / DETAILS
ARCHITECTURAL
A610A 2BR INTERIOR ELEVATIONS
ARCHITECTURAL
A901A 2BR RENDERINGS
06/18/2026
A802
1 SIM
DETAIL NUMBER
SHEET ON WHICH
DETAIL IS SHOWN
A101
A1
DETAIL CALLOUTS
EXTERIOR ELEVATIONS
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS SHOWN
A101
1 Ref
R ef
1 Ref
R ef
INTERIOR ELEVATIONS
ELEVATION NUMBER
SHEET ON WHICH
ELEVATION IS SHOWN
A909
SIM
1_______ BUILDING SECTIONS
SECTION NUMBER
SHEET ON WHICH
SECTION IS SHOWN
A909
SIM
1_______
A909
SIM
1_______ WALL SECTIONS
SECTION NUMBER
SHEET ON WHICH
SECTION IS SHOWN
FLOOR
0'-0"
FLOOR OR ROOF LEVEL NAME
VERTICAL ELEVATION
NORTH ARROW
1 DRAWING REVISION
A101
1 Ref
PROJECT
NORTH
MATCH LINE
TRUE
NORTH
GENERAL SYMBOLS LEGEND
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
EV
IT
V
ER
SI
O
N
198433
/1
/2
:4
:0
P M
A u to d e sk
D o c s:
Y
E
LL
N
P S /0 a rc h b d r.
rv t
STANDARD
ABBREVIATIONS,
SYMBOLS, & NOTES
326141A001
06/12/2026
Abbreviations
ADJ ADJACENT/ADJUSTABLE
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISH GRADE
AHU AIR HANDLING UNIT
ALT ALTERNATE NO.
ALUM ALUMINUM
ANOD ANODIZED
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPD APPROVED
APPROX APPROXIMATELY
ARCH ARCHITECT
ASSY ASSEMBLY
AUTO AUTOMATIC/AUTOMATION
AVG AVERAGE
AWI AMERICAN WOODWORKING INSTITUTE
B/B BACK TO BACK
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BOT BOTTOM
BSMT BASEMENT
BTWN BETWEEN
C / C CENTER TO CENTER
CAB CABINET
CBB CEMEMTITOUS BACKER BOARD
CEM CEMENT
CER CERAMIC
CF CUBIC FOOT / FEET
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFLG COUNTER FLASHING
CFMF COLD FORMED METAL FRAMING
CG CORNER GUARD
CIP CAST IN PLACE
CJ CONTROL JOINT / CONSTRUCTION JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
COND CONDITION
CONST CONSTRUCTION
CONT CONTINUE / CONTINUATION / CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
COP COPING
CPT CARPET
CT CERAMIC TILE
CTR CENTER
CU FT CUBIC FOOT / CUBIC FEET
CU YD CUBIC YARDS
CW COLD WATER
D DEPTH / DEEP
DBL DOUBLE
DEG DEGREE
DEL DELETE
DEMO DEMOLITION
DET DETAIL
DETN DETENTION
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DMPF DAMPPROOFING
DN DOWN
DR DOOR / DRAIN
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
E EAST
EA EACH
EIFS EXTERIOR INSULATION FINISH SYSTEM
EJ EXPANSION JOINT
EL REFERENCE ELEVATION
ELEC ELECTRIC / ELECTRICAL
ELEV ELEVATOR / ELEVATION
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER / ENGINEERING
EPDM ETHYLENE PROPYLENE DIENE MONOMOR
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EST ESTIMATE
ETC ET CETERA
EW EACH WAY
EXIST EXISTING
EXP EXPOSED / EXPAND / EXPANSION
EXT EXTERIOR / EXTERNAL / EXTINGUISHER
F / F FACE TO FACE
F F EL FINISHED FLOOR ELEVATION
FA FIRE ALARM / FACE AREA / FRESH AREA
FACP FIRE ALARM CONTROL PANEL
FD FLOOR DRAIN
FDTN FOUNDATION
Abbreviations
FDV FIRE DEPARTMENT VALVE CABINET
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FIN GR FINISHED GRADE
FIXT FIXTURE
FL FLOW LINE / FLOOR LINE
FLR FLOOR / FLOORING
FRT FRAME / FIRE RATED / FIRE RETARDANT
FT FOOT / FEET / FIRE TREATED / FULLY TEMPERED
FTG FOOTING
FURG FURRING
FURN FURNISH / FURNITURE
FUT FUTURE
GA GAGE
GAL GALLONS
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERAL / GENERATOR
GI GALVANIZED IRON
GL GLASS / GROUND LEVEL
GLZ GLAZING
GND GROUND
GYP BD GYPSUM BOARD
GYP SHTG GYPSUM SHEATHING BOARD.
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING VENTILATION AND AIR CONDITIONING
HW HOT WATER
HWH HOT WATER HEATER
IF INSIDE FACE / INTAKE FAN
IN INCHES
INCL INCLUDING
INSTL INSTALL
INSUL INSULATE / INSULATION
INT INTERIOR / INTERNAL
J BOX JUNCTION BOX
JAN JANITOR
JAN CLO JANITOR CLOSET
JT JOINT
KIT KITCHEN
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LBS POUNDS
LF LINEAR FEET
LPT LOW POINT
LT LIGHT
LTG LIGHTING
MAINT MAINTENANCE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MFG MANUFACTURING
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MOD BIT MODIFIED BITUMEN
MR MOISTURE RESISTANT
MTD MOUNTED
MTL METAL
N NORTH
N/A NOT APPLICABLE
NCOMBL NONCOMBUSTIBLE
NEG NEGATIVE
NIC NOT IN CONTACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O/O OUT TO OUT
OA OVERALL / OUTSIDE AIR
OC ON CENTER
OD OUTSIDE DIAMETER / OUTSIDE DIMENSION
OF OUTSIDE FACE
OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH OPPOSITE HAND / OVERHEAD / OVERHANG
OPNG OPENING
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
ORS OVERFLOW ROOF SCUPPER
PAT PATTERN
PBD PARTICLE BOARD
PCC PRECAST CONCRETE
PERF PERFORATED
PERM PERMANENT
PL PLATE / PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER / PLASTIC
Abbreviations
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
POL POLISHED
PR PAIR / PIPE RAIL
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRELIM PRELIMINARY
PREP PREPARATION
PROJ PROJECT
PT PAINT / PRESSURE TREATED
PT CONC POST TENSION CONCRETE
PTD PAINTED / PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE
QTY QUANTITY
R RADIUS / RISER
RA RETURN AIR
RB RUBBER BASE / RESILIENT BASE
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REBAR REINFORCED STEEL BAR
REC RECESSED
REF REFERENCE / REFRIGERATOR
REINF REINFORCED / REINFORCEMENT
REM REMOVE
REQD REQUIRED
REV REVISION
RGD INS RIGID INSULATION
RLG RAILING
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RP REFERENCE POINT
RTG RATING
RVL REVEAL
S SOUTH
SALV SALVAGE
SAN SANITARY
SCHED SCHEDULE / SCHEDULED
SCHEM SCHEMATIC
SCWD SOLID CORE WOOD DOOR
SEC SECOND
SECT SECTION
SF SQUARE FOOT / SQUARE FEET / SUPPLY FAN
SGL SINGLE
SHT SHEET
SHT MTL FLASH SHEET METAL FLASHING
SHTHG SHEATHING
SIM SIMILAR
SLNT SEALANT
SM SHEET METAL / SMALL / SURFACE MOUNTED
SMACNA SHEET METAL AIR CONDITIONING CONTRACTOR'S NATIONAL
ASSOCIATION
SPEC SPECIFICATION(S)
SPLY SUPPLY
SPRT SUPPORT
SQ SQUARE
SST STAINLESS STEEL
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STOR STORAGE
STRUC STRUCTURAL
SURF SURFACE
SUSP SUSPENDED
SYMM SYMMETRICAL
T&B TOP AND BOTTOM
TBD TO BE DETERMINED
TEL TELEPHONE
TEMP TEMPERATURE / TEMPORARY
THK THICK / THICKNESS
THRES THRESHOLD
THRU THROUGH
TO TOP OF ____
TOC TOP OF CONCRETE / TOP OF CURB
TOJ TOP OF JOIST
TOW TOP OF WALL
TRTD TREATED
TS TUBE STEEL
TYP TYPICAL
UL UNDERWRITER'S LABORATORIES
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
VAR VARIES
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VNR VENEER
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
Abbreviations
W WEST / WIDTH / WIDE
W/ WITH
W/O WITHOUT
WBL WOOD BLOCKING
WC WATER CLOSET / WALL COVERING
WD WOOD / WOOD DOOR
WDW WINDOW
WF WIDE FLANGE
WH WATER HEATER
WP WATERPROOFING / WORKING POINT
WR WATER RESISTANT / WEATHER RESISTANT
WT WEIGHT
YD YARD / YARDS
ALL EXTERIOR WALLS TO BE 2X6 STUDS AT 16" o/c TYPICAL. ALL WALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHAPTER 6 OF 2021 IRC CODE. INTERIOR WALLS TO BE 2X4 AT 16" o/c
UNLESS NOTED OTHERWISE. ALL WALLS TO MEET MIN. IECC 2021 INSULATION.
ALL FINISH MATERIALS SHALL CONFORM TO IBC & IRC FOR FLAME SPREAD AND SMOKE
DEVELOPMENT, REFER TO SPECIFIC MATERIAL SPECIFICATION SECTIONS AND FINISH SCHEDULE
FOR ADDITIONAL REQUIREMENTS. CONTRACTOR TO BE FAMILIAR WITH REQUIREMENTS AND
PROVIDE DOCUMENTATION WITH MATERIAL SUBMITTALS FOR REVIEW.
FOR THE PURPOSE OF PRICING/ESTIMATES, WHEN THERE IS A CONFLICT/DISCREPANCY IN THE
DRAWINGS AND/OR SPECIFICATIONS, THE CONTRACTOR SHALL PRICE THE HIGHER COST ITEM.
THE CONTRACTOR SHALL MAINTAIN A CURRENT/UPDATED RECORD OF DRAWINGS ON SITE AT
ALL TIMES.
EACH INSTALLER SHALL EXAMINE THE SUBSTRATE CONDITION AND/OR SITE CONDITIONS WHICH AFFECT THE QUALITY OF EACH PRODUCT TO BE INSTALLED. IF ANY CONDITIONS EXIST WHICH WILL HAVE A DETRIMENTAL EFFECT ON THE QUALITY OF THE INSTALLATION, THE INSTALLER SHALL
IMMEDIATELY ADVISE THE CONTRACTOR. INSTALLATION SHALL NOT PROCEED UNTIL THE
UNSATISFACTORY CONDITIONS ARE CORRECTED. INSTALLATION OF PRODUCTS SHALL SIGNIFY
ACCEPTANCE BY THE INSTALLER OF THE SUBSTRATE CONDITIONS.
THE CONTRACTOR SHALL BECOME FAMILIAR WITH AND COMPLY WITH OWNER’S PROCEDURES
FOR MAINTAINING A SECURE SITE AND BUILDING.
THE CONTRACTOR SHALL PROMPTLY REMOVE AND PROPERLY DISPOSE OF ALL CONSTRUCTION
AND DEMOLITION DEBRIS. THE CONTRACTOR SHALL OBTAIN APPROVAL OF OWNER FOR DETAILS
RELATED TO ALL SITE ACCESS AND REMOVAL PLANS.
THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR MEANS, METHODS AND SEQUENCES OF
CONSTRUCTION.
THE CONTRACTOR SHALL PROVIDE AND COORDINATE ALL BLOCK-OUTS, SLEEVES, INSERTS,
BOLTS, PLATES, ETC. FOR ALL TRADES PRIOR TO PLACING CONCRETE.
THE DRAWINGS SHALL NOT BE REPRODUCED FOR SUBMITTALS. DRAWINGS OR PORTIONS
THEREOF USED FOR SUBMITTALS WILL BE REJECTED AND RETURNED TO THE CONTRACTOR
WITHOUT THE APPROVAL OF THE ARCHITECT.
9 THE CONTRACTOR SHALL COORDINATE ALL WORK WITH APPLICABLE UTILITY PROVIDERS.
THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASES REQUIRED FOR
THE CONSTRUCTION AND OCCUPANCY OF THE PROJECT. THE CONTRACTOR SHALL FURNISH
COPIES OF ALL SUCH ITEMS TO THE OWNER AND ARCHITECT WITHIN 10 DAYS OF RECEIPT OF
SUCH ITEMS. IF PERMITS ARE ISSUED SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE
WORK OR IF PERMITS ARE DELAYED FOR ANY REASON, THE CONTRACTOR SHALL IMMEDIATELY
NOTIFY THE OWNER AND ARCHITECT.
THE CONTRACTOR IS RESPONSIBLE TO UNDERSTAND AND COMPLY WITH ALL APPLICABLE LAWS,
CODES, REGULATIONS AND ORDINANCES OF THE PLACE (CITY, COUNTY,DISTRICT, AND STATE)
WHERE THE PROJECT IS LOCATED.
THE DRAWINGS MAY MAKE REFERENCE TO AND/OR ILLUSTRATE ITEMS WHICH ARE NOT PART OF
THE WORK OF THE CONTRACT. THESE ‘NOT IN CONTRACT’ ITEMS AS INDICATED ARE REFERENCED
AND/OR ILLUSTRATED FOR THE CONTRACTORS REFERENCE, INFORMATION AND COORDINATION
ONLY.
THE CONTRACTOR SHALL IDENTIFY AND NOTIFY IN WRITING TO THE ARCHITECT CONFLICTS
BETWEEN THE WORK OF DIFFERENT PARTIES, AND DISCREPANCIES BETWEEN THE DOCUMENTS
AND THE ACTUAL CONDITIONS AT THE EARLIEST POSSIBLE DATE SO AS TO ALLOW REASONABLE
AND ADEQUATE TIME FOR THE CONFLICT TO BE RESOLVED WITHOUT DELAYING THE WORK. ALL
DEVIATIONS FROM THAT WHICH IS REQUIRED BY THE CONTRACT DOCUMENTS MUST BE
APPROVED IN ADVANCE BY THE ARCHITECT AND OWNER PRIOR TO PROCEEDING.
THE DRAWINGS AND SPECIFICATIONS ESTABLISH MINIMUM REQUIREMENTS FOR THE DESIGN AND
CONSTRUCTION OF THE PROJECT.
THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY THE
WORK DESCRIBED ON DRAWINGS OF ANOTHER DISCIPLINE AND MAY REQUIRE CROSS
REFERENCE. PARTIAL SETS OF DRAWINGS ARE INCOMPLETE AND SHOULD NOT BE DISTRIBUTED OR
UTILIZED BY THE CONTRACTOR.
IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL
SUB-CONTRACTORS, TRADES AND SUPPLIERS WITH REQUIREMENTS OF THE CONTRACT BEFORE
COMMENCING CONSTRUCTION, AND ASSURE THAT ALL PARTIES ARE AWARE OF ALL
REQUIREMNTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT
DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY.
THE FOLLOWING GENERAL NOTES APPLY TO THE ENTIRE SET OF DRAWINGS AND ARE NOT
SPECIFIC TO ANY ONE DISCIPLINE.
GENERAL NOTES
F10
FIRE EXTINGUISHER LOCATIONS TO BE PROVIDED PER IBC/IFC AND NFPA 10.
EXTINGUISHERS WITHIN MODULAR UNITS BY MODULAR MANUFACTURER.
F9
120 VOLT COMBO PHOTO ELECTRIC SMOKE/CARBON MONOZICE
DETECTORS WITH BATTERY BACK UP, INTER-TIED SO THAT ACTIVATION OF A
SINGLE DETECTOR CAUSES ALL DETECTORS TO GO INTO ALARM. ALL
EQUIPMENT TO BE RATED TO MEET NFPA 72.
F8
SUBMIT FIRE SUPRESSION DESIGN FOR CO APPROVAL. FIRE SUPPRESSION
DESIGN SHALL BE REVIEWED BY THE NPS REGIONAL STRUCTURAL FIRE...
F7
INTERIOR SPINKLER SYSTEM TO COMPLY WITH NFPA 13D STANDARD FOR THE
INSTALLATION OF SPRINKLER SYSTEMS IN ONE- AND TWO- FAMILY DWELLING
AND MANUFACTURED HOMES.
F6
NICET II MIN. FOR THE INSTALLATION OF AUTOMATIC SPRINKLER SYSTEMS.
NICET III MIN. FOR PROJECT OVERSIGHT NICET IV FOR SPRINKLER DESIGN.
F5
FIRE ALARM IS THE BE INSTALLED TO NFPA 72 AND NFPA 70 (NEC), AS 120V,9V
SMOKE DETECTORS WITH A 120V EXTERIOR HORN STROBE; DETECTORS TO BE
INTERCONNECTED.
F4
SPRINKLERS MADE OF CROSS-LINKED POLYETHYLENE PIPE(PEX OR EQUAL) TO
BE ALLOWED IN CEILINGS AS LONG AS ALL APPLICABLE CODES ARE MET.
F3 FIRE SUPPRESSION SYSTEMS SHALL BE DESIGNED TO MEET NFPA 13D.
F2
THE CONTRACTOR IS RESPONSIBLE FOR CONTRACTING AND
COORDINATING FIRE ALARM AND SUPRESSION SUBS TO ENSURE
COMPLIANCE WITH LATEST BUILDING CODE.
F1
FIRE SUPPRESSION SYSTEMS SHALL BE PROVIDED BY THE MODULAR BUILDING
MANUFACTURER AND SHALL BE DESIGNED IN ACCORDANCE WITH THE
REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) AND
NPS REFERENCE MANUAL 58 REQUIREMENTS.
FIRE SUPPRESSION & DETECTION
P5
WATER HEATERS TO BE ELECTIC & A 50 GALLON MIN. FOR ALL TWO
BEDROOM MODULES & A 66 GALLON MIN. FOR ALL THREE BEDROOM
MODULES.
P4
ALL FAUCETS AND BARS TO BE SATIN NICKEL UNO. ALL TOILETS TO BE
ELONGATED UNO. ALL KITCHEN SINKS TO BE UNDER-COUNTER MOUNTED
STAINLLESS STEEL UNO.
P3
WINTERIZATION DRAIN LOCATED IN THE CRAWL SPACE AND DRAINED TO THE
EXTERIOR OF THE MODULAR BUILDING PAST THE FOUNDATION WALL WITH AN
EXTERIOR FROST FREE VALVE. ALL WATER PIPING TO BE DESIGNED FOR UNITS
TO BE FULLY DRAINED FOR WINTERIZATION.
P2
ALL PLUMBING TO CONFORM TO U.P.C. (2021 EDITION) AND HIGHEST
STANDARDS OF THE TRADE. ALL WATER LINES TO BE COPPER OR PLASTIC AND
ALL SEWER LINES TO BE MIN. SCH 40 PVC. GAS LINES SHALL BE BLACK IRON
PER CODE. FIXTURES LOCATIONS SHALL BE INCLUDED IN SHOP DRAWINGS
AND SHALL BE SPECIFIED AND INSTALLED BY MODULAR BUILDING
MANUFACTURER. PLUMBING CONTRACTOR TO OBTAIN ALL NECESSARY
PERMITS. PLUMBER SHALL VERIFY LOCATION TO SEWER AND WATER MAINS
AND MAKE SERVICE CONNECTIONS AS REQUIRED. BURIED WATER SERVICE
TO BE HDPE PIPE.
P1
PLUMBING SYSTEMS SHALL BE PROVIDED BY THE MODULAR BUILDING
MANUFACTURER AND SHALL MEET ALL APPLICABLE LOCAL CODES AND GSA
REQUIREMENTS.
PLUMBING
E5 ALL INTERIOR LIGHTING TO BE LIGHT EMITTING DIODE (LED) U.N.O.
E4
EXTERIOR LIGHTING TO BE FULLY SHIELDED, MAX 2 FOOT CANDLES, 3,000K
MAX.(LED).
E3
NIGHT SKY: PROJECT SHALL COMPLY WITH NPS AND PARK LIGHTING
GUIDLINES TO REDUCE IMPACTS TO THE NIGHT SKY AND WILDLIFE. THIS WILL
INCLUDE, BUT IS NOT LIMITED TO, LOW-LEVEL LIGHTING, MINIMIZED GLARE,
DOWNWARD FOCUSED LIGHT FIXTURES, AND ENERGY EFFICIENT LIGHT
SOURCES SUCH AS LOW-PRESSURE SODIUM LAMPS.
E2
ALL ELECTRICAL SHALL CONFORM TO N.E.C (2023 EDITION) AND ALL
APPLICABLE STATE CODES. ALL SERVICES SHALL BE COPPER AND ALL WIRING
TO BE MIN. 14-2 COPPER W/ GRD. ELEC. CONTRACTOR SHALL OBTAIN
NECESSARY STATE PERMITS. FIXTURES SHALL BE SPECIFIED AND INSTALLED BY
MODULAR BUILDING MANUFACTURER, AS APPROVED THROUGH SHOP
DRAWINGS.
E1
ELECTRICAL SYSTEMS SHALL BE PROVIDED BY THE MODULAR BUILDING
MANUFACTURER AND SHALL CONFORM TO ALL APPLICABLE LOCAL
JURISDICTIONAL CODES AND GSA STANDARDS.
ELECTRICAL
M5 WOOD STOVE TO BE EPA COMPLIANT
M4
THERMOSTAT CONTROL FOR ALL COVE STYLE HEATING TO BE PROVIDE IN
EACH ROOM. LOCATIONS SHALL BE INCLUDED IN SHOP DRAWINGS.
M3
HEATING SHALL BE INSTALLED BY CERTIFIED HEATING CONTRACTOR AND
SHALL BE OF TYPE SPECIFIED AND INSTALLED BY MODULAR BUILDING
MANUFACTURER. SHOP DRAWINGS SHALL INCLUDE LOCATIONS OF ALL
HEAT REGISTERS AND RETURNS.
M2
THE CONTRACTOR SHALL COORDINATE ALL MECHANICAL CHASE SIZES WITH
MECHANICAL SUB-CONTRACTOR AND NOTIFY ARCHITECT WITH
DISCREPANCIES IN THE FIELD.
M1
MECHANICAL SYSTEMS SHALL BE PROVIDED BY THE MODULAR BUILDING
MANUFACTURER & SHALL COMPLY WITH ALL APPLICABLE LOCAL CODES
AND GSA REQUIREMENTS.
MECHANICAL
DISCIPLINE NOTES
30" MIN CLR
M
A X
(B) 10"-24"
(A) 0" TO 20"
M
IN
M
A X
4" MAX
(B
M
A X
(A
M
A X
(B) 20" TO 25" MAX
M
IN
11" MIN6" MAX
8" MIN
M
IN
M
IN
12" MAX 42" MIN
39" MIN TO 41" MAX
M
IN
T
O
M A
X
M
IN
T
O
M A
X
M
IN
54" MIN
M
IN
12" MIN24" MIN
M
IN
T
O
M A
X
36" MIN
24" MIN
42" MAX
36" MAX
M
A X
M
IN
/2
M
IN
M
IN 6"
3'-0"
M
IN
60" MIN
60" MIN
M
IN
6" MAX
15" MAX
M
A X
A B
O V
E G
R A
B B
A R
5'-0"
M
IN
M
A X
M
A X
A B
O V
E G
R A
B B
A R
27" MAX
16" MIN
M A
X
(A) 0" TO 10" MAX
(B
M
A X
(A
M
A X
M
IN
H G
T O
F L
A V
/S
IN
K S
M
A X
2 1/2" MAX
/2
M A
X
M A
X
15" MIN - 16" MAX
22" MIN - 23" MAX
A
F F
4" 4"
UNLIMITED
UNLIMITED
UNLIMITED
1'-2"4" 4"
M
IN
T
O
M A
X
12" MIN
TOE CLEARANCES [306.2]
KNEE CLEARANCES [306.3]
HEIGHT OF LAVS/SINKS [606.3]
REACH RANGES [308]
PROTRUDING OBJECTS [307]
CIRCULATION
AISLE
TOE CLEARANCE
KNEE CLEARANCE
MAX REACH HEIGHT
OBSTRUCTION
LIMITS
MIN REACH HEIGHT
IF UNOBSTRUCTED
INCLUDING BUT
NOT LIMITED TO
OUTLETS AND
JUNCTION BOXES
(TYP.)
INCLUDING BUT
NOT LIMITED TO
HIGH OUTLETS,
INTERCOMS,
THERMOSTATS,
FIRE ALARM PULL,
CARD READERS,
ARMING
STATIONS
BATHROOM
HEIGHT
PROTRUDING
DISPENSER (DARK GREY)
RECESSED DISPENSER
(DASHED)
WHEELCHAIR ACCESSIBLE COMPARTMENT GRAB BAR AND
DISPENSER LOCATION
TRANSFER-TYPE SHOWER COMPARTMENT SIZE AND
CLEARANCE(CONTROL WALL)
SHOWER
CONTROL
AND
HANDSHOWER
LOCATION
MIN SIDE REACH IF
UNOBSTRUCTED
MAX SIDE REACH
MAX HEIGHT OF
SIDE OBSTRUCTION
TOE
CLEARANCE
WATER CLOSET AND TOILET COMPARTMENTS [604] SHOWER COMPARTMENTS [608] L SHAPE SHOWER COMPARTMENT SEAT [610]
(B) L-SHAPED SEAT
(A) RECTANGLE SEAT
FOLDING
SHOWER
SEAT
ACCESSIBLE FORWARD REACH RANGES AND CLEARANCES
DIAGRAM (SIDE VIEW)
ACCESSIBLE SIDE REACH RANGES AND CLEARANCES
DIAGRAM (SIDE VIEW)
ACCESSIBLE FORWARD REACH CLEARANCES DIAGRAM (PLAN
VIEW)
L-SHAPED SHOWER COMPARTMENT
CONTROL WALL
LOCKER
NOTE: AT LEAST
5% (NOT LESS
THAN 1) LOCKERS
SHALL BE
ACCESSIBLE.
PROVIDE 30"X48"
CLEAR SPACE
FOR PARALLEL
APPROACH.
TYPICAL ACCESSIBLE FIXTURE
HEIGHTS DIAGRAM
NOTE: OPERABLE PARTS SHALL BE
OPERABLE WITH ONE HAND AND
SHALL NOT REQURE TIGHT
GRASPING,
PINCHING OR TWISTING OF THE
WRIST. THE FORCE REQUIRED SHALL
BE 5LB MAX.
GRAB HEIGHT
NOTE: OPERABLE PARTS SHALL BE OPERABLE WITH
ONE HAND AND SHALL NOT REQURE TIGHT
GRASPING,
PINCHING OR TWISTING OF THE WRIST. THE FORCE
REQUIRED SHALL BE 5LB MAX.
OPERABLE PARTS [309.4]
ACCESSIBLE
ROBE HOOK
WHEELCHAIR ACCESSIBLE COMPARTMENT GRAB BAR/TOILET
LOCATION AND CLEARANCE
OPERABLE PARTS [309.4]
LIMITS OF PROTRUDING OBJECTS DIAGRAM
(SIDE VIEW)
PROTRUDING OBJECTS [307]
REDUCED VERTICAL CLEARANCE DIAGRAM (SIDE VIEW)
REACH RANGES [308]
SHOWER COMPARTMENTS [608]
ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
DIAGRAM (PLAN VIEW)
SHOWER COMPARTMENTS [608]
LIGHT
SWITCH
DUPLEX
OUTLET
(TYP.)
DUPLEX
OUTLET
(HIGH)
DESK
INTERCOM
OUTLET
TELEPHONE
OR DATA
OUTLET
THERMOSTAT
OR FIRE ALARM
SPECIAL
PURPOSE
OUTLETS
SPECIAL
PURPOSE
OUTLETS
JUNCTION
BOX
SWITCH AT
DOOR OR CASED
OPENING
AUDIBLE &
VISUAL FIRE
ALARM
SECURITY
STROBE LIGHT
(BLUE LIGHT)
ELECTRICAL PANEL
BOARD
(RECESSED)
FIXED SHOWER
HEAD
FLEXIBLE 60"
SHOWER SPRAY
HOSE
FLEXIBLE 60"
BATHTUB SPRAY
HOSE
SINGLE LEVER
SHOWER MIXING
VALVE
RECESSED
SHOWER STALL
SOAP DISH
ACCESSIBLE
ROBE HOOK
GRAB BARS IN ACCESSIBLE
SHOWER (CONTROL WALL)
SHOWER CURTAIN
ROD
ACCESSIBLE
SHOWER PLAN
NOTE: CA REQUIREMENT
ACCESSIBLE SINK PLAN ACCESSIBLE LAVATORY HC W.C. ACCESSIBLE WATER
CLOSET (SIDE VIEW)
DRINKING FOUNTAIN OR WATER
COOLER (SIDE VIEW) THRESHOLD ON ACCESSIBLE
PATH
M
IN
L O
W R
E A
C H
M A
X F
O R
W A
R D
R E
A C
H
1' -6
M A
X F
O R
W A
R D
R E
A C
H
3'-0"
4' -0
5' -0
5' -0
2' -0
M
T G
B R
A C
K E
T
3' -2
B
O T
O F
M T
G B
R A
C K
E T
4' -0
T
O P
O F
M T
G B
R A
C K
E T
3' -4
3' -4
4' -0
3'-0"
3' -0
MIN
5'-0"
FOLDING SHOWER SEAT
SLOPE TO DRAIN 1/2"
PER FOOT MAX.
SHOWER GRAB BARS
M A
X
1' -7
2'-6"
4' -0
8" MIN
6" MAX
9" M
IN
2' -5
M
IN
C
LR
3' -4
M
A X
2' -1
0" M
A X
T O
R
IM
LAVATORIES ADJ TO A WALL SHALL BE
MOUNTED 18" MIN (OR GREATER AS
INDICATED ON PLANS) FROM ADJ WALL TO
CENTERLINE OF FIXTURE.
1' -5
WATER CLOSETS SHALL BE MOUNTED 18"
FROM ADJACENT WALL OR TOILET PARTITION
TO CENTERLINE OF FIXTURE.
1' -5
T
Y P
1'-5" TO 1'-7"
8" MIN
6" MAX
2' -3
M
IN
9" M
IN
1/ 4"
M A
X
1/ 2"
M A
X
5' -0
WALL MOUNTED FE COAT HOOKS (WALL-
MTD)
COAT HOOKS
(DOOR-MTD)
MIRROR
(WALL MOUNT)
MIRROR ABOVE COUNTER
3'-0"
1'-8"
4' -0
SEE PLAN
2' -6
4"
4"
3' -0
M
IN
F
O R
C O
N T
R O
LS
24" MAX
M
IN
C
LR
5' -0
18" MIN
CLR
32" MIN,
SINGLE OCCUPANCY TOILET
MIN
1'-6"
MAX. 12" ENCROACHMENT WITH A MIN. 67" LANDING FOR DOORS
THAT SWINGS INWARD; MAX 10" OVERLAP OF KNEE AND TOE
4' -0
3' -9
CLEAR FLOOR SPACE REQUIREMENTS
BOTTOM OF
MIRROR
1' -0
M
IN
6' -0
M
A X
M A
X S
ID
E
R E
A C
H
M
A X
S
ID
E R
E A
C H
M
IN
L O
W R
E A
C H
M
IN
. F O
R C
O N
T R
O L
M
IN
L O
W R
E A
C H
M A
X F
O R
W A
R D
R E
A C
H
M A
X S
ID
E
R E
A C
H
3'-4"
MAX
12"
42"
36" 6"
TOILET TISSUE
DISPENSER
M A
X
CLEAR WIDTH AT 180° TURNA
T-SHAPED TURNING SPACE
C
(6
M
IN
M
IN
(36" MIN)
3'-6" MIN
(36" MIN)
3'-6" MIN
1'-0" MIN 3'-0" MIN 1'-0" MIN
M
IN
M
IN 5
M
IN
5'-0" MIN
THE SPACE SHALL
BE PERMITTED TO
INCLUDE KNEE AND
TOE CLEARANCE
ONLY AT THE END
OF EITHER THE
BASE OR ONE ARM.
THE SPACE
SHALL BE
PERMITTED TO
INCLUDE KNEE
AND TOE
CLEARANCE.
CIRCULAR TURNING SPACE
B
WHEEL CHAIR TURNING SPACE AND TOE AND KNEE CLEARANCES
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:4
:0
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
TYPICAL MOUNTING
HEIGHTS
326141A002
06/12/202606/18/2026
CONTINUOUS METAL
RIDGE VENT
STANDING SEAM METAL ROOF; RE:
SECTION 07 41 13.16 STANDING METAL
ROOF PANELS
UNDERLAYMENT; RE:
SECTION 07 41 13.16 STANDING METAL
ROOF PANELS
SHEATHING; RE:
SECTION 06 16 00 SHEATHING
PREFINISHED FLEXIBLE METAL
FLASHING
VENTILATED SOFFIT; RE:
SECTION 07 46 46 FIBER-CEMENT
SIDING
FIBER CEMENT SIDING; RE:
SECTION 07 46 46 FIBER-CEMENT
SIDING
1/2 GLASS MAT GYPSUM RE;
SECTION 06 16 00 SHEATHING
GYPSUM BOARD CEILING
SUBFLOOR DECKING
WOOD TRIM
CAST IN PLACE CONCRETE; RE:
STRUCTURAL
MANUF. STANDARD SIDING STARTER
STRIP
SPRAY FOAM INSULATION;
RE: A000 FOR R-VALUES;
INSPECT UPON DELIVERY
10 MIL MIN. VAPOR
RETARDER
CONCRETE FACED INSULATION
BOARD; RE: A000 FOR R-VALUES;
CONFIRM FROST DEPTH WITH
STRUCTURAL
DRAIN TILE
GYPSUM BOARD
BATT INSULATION; RE:
A000 FOR R-VALUES
SPRAY FOAM INSULATION;
RE: A000 FOR R-VALUES;
INSPECT UPON DELIVERY
SPRAY FOAM INSULATION;
RE: A000 FOR R-VALUES;
INSPECT UPON DELIVERY
FIBERGLASS WINDOW; FLASH & SHIM
WINDOW PER MANUFACTURER
RECOMMENDATIONS
PREFINISHED FLEXIBLE METAL
FLASHING; ENSURE METAL FLASHING
DOES NO INTERRUPT CRITICAL SEALS
BETWEEN WINDOW FRAME AND ROUGH
OPENING, TYP.
PREFINISHED FLEXIBLE METAL
FLASHING; ENSURE METAL FLASHING
DOES NO INTERRUPT CRITICAL SEALS
BETWEEN WINDOW FRAME AND ROUGH
OPENING, TYP.
WOOD FRAMING
SELF-ADHESIVE MEMBRANE
RIGID INSULATION; RE: A000 FOR
R-VALUES
VAPOR RETARDER
TAPE
3" 3"
NOTE(S):
1. WHERE WOOD FRAMING CANTILEVERS CONCRETE WALL,
ADJUST METAL BASE FLASHING TO SUIT.
2. MAINTAIN FIBER CEMENT SIDING MANUFACTURER'S MIN.
CLEARANCE BETWEEN SIDING AND GRADE. SLOPE GRADE AWAY
FROM BUILDING. REGRADE AS REQUIRED.
3. INSTALL FIBER CEMENT SIDING PER MANUFACTURER'S
RECOMMENDATIONS.
4. SPACE PLANKS 1/8" (HORIZ.) MAINTAIN 3/8" MIN. EDGE DISTANCE
FROM END OF PLANKS WITH FASTENERS AND 1" FROM THE TOP
EDGE.
FURRING STRIPS WITH INSECT
SCREENS
TRIM
FILLET BEAD OF SEALANT
MINIMUM CODE REQUIRED
VENTILATION CHUTE OR FURRING
CHANNEL
FLOOR FINISH
UNDERLAYMENT; RE:
SECTION 07 41 13.16 STANDING METAL
ROOF PANELS
SHEATHING; RE:
SECTION 06 16 00 SHEATHING
WATERPROOFING/DAMPROOFING;
REFER TO MODULAR BUILDINGS
SPECIFICATION
RE: IRC FOR MIN GAP
RE: STRUCTURAL
SHIM & SEAL AS REQUIRED BY MANUF.
SHIM & SEAL AS REQUIRED BY MANUF.
FLUID-APPLIED AIR BARRIER; WEATHER
BARRIER
FLUID-APPLIED AIR BARRIER; WEATHER
BARRIER; WRAP BARRIER AS
REQUIRED BY MANUFACTURER AT
OPENINGS
R E
: C
IV
IL
8" M
IN
, T
Y P
SYSTEM COMPONENTS & FIRE RATING
REQUIREMENTS MAY VARY PER UNITS SPECIFIC
LOCATION. FIRE RESISTIVE CONTRUCTION MUST
COMPLY WITH NPS REFERENCE MANUAL 58 AND THE
IWUIC.
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:4
:0
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
ASSEMBLY
326141A003
06/12/2026
1 1/2" = 1'-0"A003
A1 EXTERIOR ASSEMBLIES
PRE-FINISHED WINDOW TRIM
WINDOW
PRE-FINISHED WINDOW TRIM
WINDOW
TYPE A1 TYPE A2 TYPE A3
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:4
:0
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
2BR DOOR & WINDOW
TYPES / SCHEDULES /
DETAILS
326141A005A
06/12/2026
DOOR SCHEDULE
NO. ROOM NAME
ROOM
NO.
DOOR FRAME
DOOR COMMENTSWIDTH HEIGHT THICK DOOR TYPE MAT'L FIN GLAZ MAT'L FINISH
LEVEL 01
A101 GREAT ROOM 3 3'-0" 6'-8" 1 3/4" Type A1 - Pre-Hung GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors
A102 MUD ROOM 10 3'-0" 6'-8" 1 3/4" Type A1 - Pre-Hung GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors
A103 MUD ROOM 10 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
A104 BATH 01 9 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
A105A BEDROOM 01 8 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
A105B BEDROOM 01 8 6'-0" 6'-8" 1 3/8" Type A3 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
A106A BEDROOM 02 2 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
A106B BEDROOM 02 2 6'-0" 6'-8" 1 3/8" Type A3 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
A106C BATH 02 5 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
A107 LAUNDRY/UTILITY 7 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
WINDOW SCHEDULE
TYPE MARK WIDTH HEIGHT MATERIAL COMMENTS
AW1 3'-0" 5'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO
RECEIVE STORM SCREEN.
AW2 3'-0" 3'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO
RECEIVE STORM SCREEN.
DOOR PANEL TYPES
WINDOW TYPES
AW1
AW2
DEADBOLT SPECIFICATIONS
SCHLAGE B SERIES GRADE 1 DEADBOLTS CORE LESS 1-3/4 SATIN
NICKEL US15 SCHB660J626
ZZ_SP-DOORHW_6929
HOT# 124572
CYLINDER CORE SPECIFICATIONS
SCHLAGE ZZ_SP-DOORHW_6932 SCH23-030E626 IC CORE CYLINDER E CORE
PROVIDE 2 BLANK KEYS
HOT# 117977
ENTRY DOOR HANDLE SPECIFICATIONS
SCHLAGE ND SERIES GRADE 1 CYLINDRICAL LOCK RHOES HANDLE ND 105
PASSAGE LATCH 1-3/4 2-3/4 SATIN NICKEL SCHND10SRHO626
ZZ_SP-DOORHW_6930
HOT# 133193
NOTE: LOCKSETS WILL REQUIRE EXTERIOR DOORS TO BE CUT TO RECEIVE COMMERCIAL LOCKSET.
DOOR HARDWARE
* ALL BEDROOMS TO RECEIVE AW1 WINDOWS IN COMPLIANCE WITH 2024 IRC SECTION R319 MINIMUMS.
AW1
NET CLEAR WIDTH: 34" - 36"
NET CLEAR OPENING HEIGHT: 32" - 34"
NET CLEAR OPENING AREA: 8.0SF - 8.5SF
IRC MINIMUMS
NET CLEAR WIDTH: 20"
NET CLEAR HEIGHT:24"
NET CLEAR OPENING AREA: 5.7SF
PRE-FINISHED WINDOW TRIM
WINDOW
TYPE B1 TYPE B2 TYPE B3 TYPE B4
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:0
:1
P M
A u to d e sk
D o c s:
/1
Y
E L L N
P S a rc h b d r_ a d a .r v t
2BR ABA DOOR &
WINDOW TYPES /
SCHEDULES / DETAILS
326141A/326104A005B
05/28/25
WINDOW SCHEDULE
TYPE MARK WIDTH HEIGHT MATERIAL COMMENTS
BW1 3'-0" 5'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
BW2 3'-0" 3'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
DOOR SCHEDULE
NO. ROOM NAME
ROOM
NO.
DOOR FRAME
DOOR COMMENTSWIDTH HEIGHT THICK Door Type MAT'L FIN GLAZ MAT'L FINISH
LEVEL 01
B101 GREAT ROOM 6 3'-0" 6'-8" 1 3/4" TYPE B1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors
B102 MUD ROOM 3 3'-0" 6'-8" 1 3/4" TYPE B1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors
B103 MUD ROOM 3 3'-0" 6'-8" 1 3/8" TYPE B2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
B104 BATH 01 2 3'-0" 6'-8" 1 3/8" TYPE B2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
B105A BEDROOM 01 9 3'-0" 6'-8" 1 3/8" TYPE B2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
B105B BEDROOM 01 9 6'-0" 6'-8" 1 3/8" TYPE B3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
B106A BEDROOM 02 10 3'-0" 6'-8" 1 3/8" TYPE B2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
B106B BEDROOM 02 10 6'-0" 6'-8" 1 3/8" TYPE B3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
B106C BATH 02 ABA 4 3'-0" 6'-8" 1 3/8" TYPE B2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
B106D BATH 02 ABA 4 2'-6" 6'-8" 1 3/8" TYPE B4 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
DOOR PANEL TYPES
DEADBOLT SPECIFICATIONS
SCHLAGE B SERIES GRADE 1 DEADBOLTS CORE LESS 1-3/4 SATIN
NICKEL US15 SCHB660J626
ZZ_SP-DOORHW_6929
HOT# 124572
CYLINDER CORE SPECIFICATIONS
SCHLAGE ZZ_SP-DOORHW_6932 SCH23-030E626 IC CORE CYLINDER E CORE
PROVIDE 2 BLANK KEYS
HOT# 117977
ENTRY DOOR HANDLE SPECIFICATIONS
SCHLAGE ND SERIES GRADE 1 CYLINDRICAL LOCK RHOES HANDLE ND 105
PASSAGE LATCH 1-3/4 2-3/4 SATIN NICKEL SCHND10SRHO626
ZZ_SP-DOORHW_6930
HOT# 133193
NOTE: LOCKSETS WILL REQUIRE EXTERIOR DOORS TO BE CUT TO RECEIVE COMMERCIAL LOCKSET.
DOOR HARDWARE
BW1
BW2
WINDOW TYPES
* ALL BEDROOMS TO RECEIVE AW1 WINDOWS IN COMPLIANCE WITH 2024 IRC SECTION R319 MINIMUMS.
BW1
NET CLEAR WIDTH: 34" - 36"
NET CLEAR OPENING HEIGHT: 32" - 34"
NET CLEAR OPENING AREA: 8.0SF - 8.5SF
IRC MINIMUMS
NET CLEAR WIDTH: 20"
NET CLEAR HEIGHT:24"
TYPE C1 TYPE C3TYPE C2
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:2
:3
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
3BR DOOR TYPES /
SCHEDULES / DETAILS
326141A005C
06/12/2026
DOOR SCHEDULE
NO. ROOM NAME
ROOM
NO.
DOOR FRAME
DOOR COMMENTSWIDTH HEIGHT THICK TYPE MAT'L FIN GLAZ MAT'L FINISH
LEVEL 01
C101A FOYER 1 3'-0" 6'-8" 1 3/4" TYPE C1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors
C101B FOYER 1 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
C103 HALL 3 4'-0" 6'-8" 1 3/8" TYPE C3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
C104A BEDROOM 02 4 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
C104B BEDROOM 02 4 4'-0" 6'-8" 1 3/8" TYPE C3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
C106A LAUNDRY 6 3'-0" 6'-8" 1 3/4" TYPE C1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; 60 Min Fire. Solid core door, code-compliant hardware, including gasketing, spring hinge / self-closing; Contracting officer to select from manufacturer's standard colors, Spring Hinge, Seals
C106B LAUNDRY 6 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
C107A BEDROOM 03 7 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
C107B BEDROOM 03 7 4'-0" 6'-8" 1 3/8" TYPE C3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
C108 BATH 02 8 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
C109 DINING 9 3'-0" 6'-8" 1 3/4" TYPE C1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors
C111A BEDROOM 1 11 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
C111B BEDROOM 1 11 3'-0" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR Barn Door, Color: Contracting officer to select from manufacturer's standard colors
C113 BATH 01 13 2'-6" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
D114 GARAGE 14 3'-0" 6'-8" 1 3/4" TYPE C1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors
DOOR PANEL TYPES
DEADBOLT SPECIFICATIONS
SCHLAGE B SERIES GRADE 1 DEADBOLTS CORE LESS 1-3/4 SATIN
NICKEL US15 SCHB660J626
ZZ_SP-DOORHW_6929
HOT# 124572
CYLINDER CORE SPECIFICATIONS
SCHLAGE ZZ_SP-DOORHW_6932 SCH23-030E626 IC CORE CYLINDER E CORE
PROVIDE 2 BLANK KEYS
HOT# 117977
ENTRY DOOR HANDLE SPECIFICATIONS
SCHLAGE ND SERIES GRADE 1 CYLINDRICAL LOCK RHOES HANDLE ND 105
PASSAGE LATCH 1-3/4 2-3/4 SATIN NICKEL SCHND10SRHO626
ZZ_SP-DOORHW_6930
HOT# 133193
NOTE: LOCKSETS WILL REQUIRE EXTERIOR DOORS TO BE CUT TO RECEIVE COMMERCIAL LOCKSET.
DOOR HARDWARE
TYPE D1 TYPE D3TYPE D2
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:3
:4
P M
A u to d e sk
D o c s:
/1
Y
E L L N
P S a rc h b d r_ a d a .r v t
3BR ABA DOOR TYPES /
SCHEDULES / DETAILS
326141A005D
06/12/2026
DOOR SCHEDULE
NO. ROOM NAME
ROOM
NO.
DOOR FRAME
DOOR COMMENTSWIDTH HEIGHT THICK TYPE MAT'L FIN GLAZ MAT'L FINISH
LEVEL 01
D101A FOYER 1 3'-0" 6'-8" 1 3/4" TYPE D1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors
D101B FOYER 1 3'-0" 6'-8" 1 3/8" TYPE D2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
D103 HALL 3 4'-0" 6'-8" 1 3/8" TYPE D3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
D104A BEDROOM 02 4 2'-8" 6'-8" 1 3/8" TYPE D2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
D104B BEDROOM 02 4 4'-0" 6'-8" 1 3/8" TYPE C3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
D106A LAUNDRY 6 3'-0" 6'-8" 1 3/4" TYPE D1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; 60 Min FRR. Solid core door. Code-compliant hardware, including gasketing, spring hinge / self-closing, must meet ABA requirements for clear opening width, maneuvering clearances, opening force; Color: Contracting officer to select from manufacturer's standard colors, Spring Hinge, Seals
D106B LAUNDRY 6 2'-8" 6'-8" 1 3/8" TYPE D2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
D107A BEDROOM 03 7 2'-8" 6'-8" 1 3/8" TYPE D2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
D107B BEDROOM 03 7 4'-0" 6'-8" 1 3/8" TYPE C3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
D108 BATH 2 8 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors
D109 DINING 9 3'-0" 6'-8" 1 3/4" TYPE D1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors
D111A BEDROOM 01 11 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: As selected by contracting officer from manufacturer's full range of colors
D111B BEDROOM 01 11 3'-0" 6'-8" 1 3/8" TYPE D2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR Barn Door, Color: Contracting officer to select from manufacturer's standard colors
D113 BATH 01 13 3'-0" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR Pocket Door, Color: Contracting officer to select from manufacturer's standard colors
D114 GARAGE 14 3'-0" 6'-8" 1 3/4" TYPE D1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors
DOOR PANEL TYPES
DEADBOLT SPECIFICATIONS
SCHLAGE B SERIES GRADE 1 DEADBOLTS CORE LESS 1-3/4 SATIN
NICKEL US15 SCHB660J626
ZZ_SP-DOORHW_6929
HOT# 124572
CYLINDER CORE SPECIFICATIONS
SCHLAGE ZZ_SP-DOORHW_6932 SCH23-030E626 IC CORE CYLINDER E CORE
PROVIDE 2 BLANK KEYS
HOT# 117977
ENTRY DOOR HANDLE SPECIFICATIONS
SCHLAGE ND SERIES GRADE 1 CYLINDRICAL LOCK RHOES HANDLE ND 105
PASSAGE LATCH 1-3/4 2-3/4 SATIN NICKEL SCHND10SRHO626
ZZ_SP-DOORHW_6930
HOT# 133193
NOTE: LOCKSETS WILL REQUIRE EXTERIOR DOORS TO BE CUT TO RECEIVE COMMERCIAL LOCKSET.
DOOR HARDWARE
PRE-FINISHED WINDOW TRIM
WINDOW
PRE-FINISHED WINDOW TRIM
WINDOW
PRE-FINISHED WINDOW TRIM
WINDOW
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:2
:3
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
3BR WINDOW TYPES /
SCHEDULES / DETAILS
326141A006C
06/12/2026
WINDOW SCHEDULE
TYPE MARK WIDTH HEIGHT MATERIAL COMMENTS
CW1 3'-0" 5'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
CW3 4'-0" 4'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
CW4 3'-6" 1'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
CW5 5'-0" 2'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
CW1
CW2
CW3
CW4
WINDOW TYPES
* ALL BEDROOMS TO RECEIVE AW1 WINDOWS IN COMPLIANCE WITH 2024 IRC SECTION R319 MINIMUMS.
CW1
NET CLEAR WIDTH: 34" - 36"
NET CLEAR OPENING HEIGHT: 32" - 34"
NET CLEAR OPENING AREA: 8.0SF - 8.5SF
IRC MINIMUMS
NET CLEAR WIDTH: 20"
NET CLEAR HEIGHT:24"
PRE-FINISHED WINDOW TRIM
WINDOW
PRE-FINISHED WINDOW TRIM
WINDOW
PRE-FINISHED WINDOW TRIM
WINDOW
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:3
:4
P M
A u to d e sk
D o c s:
/1
Y
E L L N
P S a rc h b d r_ a d a .r v t
3BR ABA WINDOW TYPES
/ SCHEDULES / DETAILS
326141A006D
06/12/2026
WINDOW SCHEDULE
Type Mark Width Height MATERIAL Comments DW1 3'-0" 5'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
DW3 4'-0" 4'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
DW4 3'-6" 1'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
DW5 5'-0" 2'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
DW1
DW2
DW3
DW4
WINDOW TYPES
* ALL BEDROOMS TO RECEIVE AW1 WINDOWS IN COMPLIANCE WITH 2024 IRC SECTION R319 MINIMUMS.
DW1
NET CLEAR WIDTH: 34" - 36"
NET CLEAR OPENING HEIGHT: 32" - 34"
NET CLEAR OPENING AREA: 8.0SF - 8.5SF
IRC MINIMUMS
NET CLEAR WIDTH: 20"
NET CLEAR HEIGHT:24"
R a n g e
WH
FD
R e fr ig e ra to r
DW
SD
SD
SD/CO
SD
A610A
A6
A610A
A9
A610A A4
A8
A610AA2
A1
B1
A200A
A
A A
A1
A200A
B
A A
A610A A3
A610A
A7
BEDROOM 02
A106A
AW2 AW2
AW1
AW1
AW1
AW1
AW1AW1
AW1
AW1
GREAT ROOM
KITCHEN
BATH 02
HALL
LAUNDRY/UTILITY
BEDROOM 01
BATH 01
MUD ROOM
A106C
A107
A101
A
A
A
A105A
A105B
A106B
LVP-1
LVP-1
TL-1
LVP-1
LVP-1
LVP-1
LVP-1
LVP-1
CPT-1
CPT-1
A
C
B
1 2 3
48'-0"
40'-0" 8'-0"
'-0
'-0
'-0
'-0
7'-8 1/2"
3'-8 1/2"
3'-0"
6'-7"
'-6
'-8
6" 12'-0" 5'-4 1/2" 8" 8 1/2"
4'-10" 6'-0 1/2" 4'-0" 5'-4 1/2" 6"
'-3
/2
'-3
'-6
'-9
/2
'-8
/2
'-6
'-1
/2
8'-0"40'-0"
48'-0"
'-0
BENCH &
COAT RACK
INCLUDE BLOCKING
FOR TV MOUNT
ABOVE RECEPTACLE
BRACED WALL
BEHIND WALL FINISH
2X6 WALL FOR DRYER VENT
TO CLEAR TRUSS
BRACED WALL
BEHIND WALL FINISH
WOOD STOVE W/
48"X48" HEARTH PAD
1'-0"
1'-4" MIN CLR
1'-11" MIN CLR
DISHWASHER
EXTERIOR VENT
RANGE HOOD W/ MICROWAVE
PANTRY
CABINET
LINEN
CABINET
4" RADON PIPE
LINEN CABINET
WASHER
& DRYER
5X SHELVES
6X6 POST
8X8
POST
8X8
POST
8X8
POST
8X8
POST
8X8
POST
6X6 POST
CRAWL
SPACE
ACCESS
'-6
/8
'-1
/2
'-2
/2
'-6
'-1
/2
'-5
'-4
/2
'-4
/2
10'-8"
2'-8"
'-2
6" 12'-0" 5'-9 1/2" 5'-3" 6'-6 1/2" 9'-5" 6"
/2
/2
A5
A10
PROVIDE STAIRS AS
REQUIRED BY SITE SPECIFIC
GRADING; RE CIVIL
ELEV=100'-0"
ELEV=100'-0"
ELEV=100'-0"
ELEV=100'-0"
A
C
B
1 2 3
2'-1 1/2"
2'-0"1'-10"
3'-9"
'-0
'-5
'-1
10'-7"
4'-10"
CENTER
CENTER
E Q
E Q
CENTER CENTER
CENTER
CENTER
WALL MOUNTED
LINEAR LED LIGHT
FAN WITH INTEGRATED
LED LIGHT
FAN WITH INTEGRATED
LED LIGHT
2'-2"
'-8
CENTER LIGHT
ABOVE SINK
'-0
'-3
/2
CEILING
ACCESS
PANEL
FIRE SUPPRESSION SYSTEM TO BE PROVIDED.
DELEGATED DESIGN. PROVIDE UPONOR AQUASAFE
SYSTEM OR APPROVED EQUAL. PROVIDE FIRE
SUPPRESSION SYSTEM DRAWINGS, HYDRAULIC
CALCULATIONS, AND MANUFACTURER'S PRODUCT
DATA SHEETS FOR REVIEW AND APPROVAL BY THE
NPS FIRE CODE OFFICIAL/AHJ OR DESIGNEE, PRIOR
TO INSTALLATION.
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:4
:0
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
2BR FLOOR & REFLECTED
CEILING PLAN
326141A101A
06/12/2026
1/4" = 1'-0"A101A
A1 FLOOR PLAN
1/4" = 1'-0"A101A
C1 REFLECTED CEILING PLAN
NOTES PLAN
1 REFERENCE ALL GENERAL NOTES ON SHEET A001
2 NIGHT SKY: PROJECT SHALL COMPLY WITH NPS AND PARK LIGHTING GUIDLINES TO REDUCE IMPACTS TO THE
NIGHT SKY AND WILDLIFE. THIS WILL INCLUDE, BUT IS NOT LIMITED TO,…