This is an architectural design document set for modular residential housing units at Yellowstone National Park, prepared by Stantec and marked as preliminary/not for construction. The document provides detailed construction plans for both 2-bedroom and 3-bedroom modular housing units, including standard and Americans with Disabilities Act (ABA) compliant versions, with design dates of June 12, 2026 and revisions through June 18, 2026.

The architectural specifications establish minimum design and construction requirements across multiple disciplines. Key specifications include: 2x6 exterior wall studs at 16-inch on-center spacing and 2x4 interior walls at 16-inch on-center with insulation meeting 2021 IECC standards; metal standing seam roofs with fiber cement siding; fiberglass windows with storm screens and decorative non-functional shutters; and 8-foot ceiling heights standard throughout. Water heaters must be 50-gallon minimum for 2-bedroom units and 66-gallon minimum for 3-bedroom units, with all plumbing conforming to 2021 Uniform Plumbing Code. Electrical systems require 2023 National Electric Code compliance with all interior LED lighting, exterior fully-shielded LED lighting limited to 2 foot-candles at 3,000K maximum, and compliance with NPS night sky protection guidelines. Fire suppression systems must comply with NFPA 13D standards for residential sprinkler systems, requiring NICET Level II minimum for installation, Level III for project oversight, and Level IV for design. All modular units must be reviewed, approved, and stamped by the manufacturer prior to fabrication and installation, with the contractor responsible for coordinating all work with applicable utility providers and obtaining required permits within ten days of receipt. ABA-compliant units include accessible kitchens, bathrooms, grab bars, and ramp requirements conforming to 2024 ABA standards.

View the file

Other files

File Type Posted
Sol_140P2026R0078_Amd_0004.pdf PDF
B08_Attachment_7_Limitations_on_Subcontracting_Report_0004.xlsx XLSX spreadsheet
B09-140P2026R0078-Amd_4_0004.pdf PDF
Sol_140P2026R0078_Amd_0003.pdf PDF
B09_Amendment_3__Past_Performance_Questionnaire_0003.docx DOCX document
B09_Amendment_3_Questions_and_Answers_0003.pdf PDF
B09_Amendment_3_Yellowstone_Canyon_Project_Report_0003.pdf PDF
B09_Amendment_3_estimated_cut_and_fill_quantities_0003.pdf PDF
B09_Amendment_3_Yellowstone_NE_Entrance_Project_Report_0003.pdf PDF
B09_Amendment_3_Yellowstone_Mammoth_Project_Report_0003.pdf PDF
B09_Amendment_3__Project_Experience_Questionnaire_0003.docx DOCX document
B09_Amendment_3_General_References_0003.docx DOCX document
B09-Attachment_2_-_Revised_Final_Construction_Drawings_2026_08_18_Part3_0002.pdf PDF
B09-Attachment_2_-_Revised_Final_Construction_Drawings_2026_08_18_Part5_0002.pdf PDF
B09-Attachment_2_-_Revised_Final_Construction_Drawings_2026_08_18_Part2_0002.pdf PDF
B09-Attachment_2_-_Revised_Final_Construction_Drawings_2026_08_18_Part6_0002.pdf PDF
Sol_140P2026R0078_Amd_0002.pdf PDF
B09-Attachment_1_-_Revised_Final_CD_Specifications_2026_08_18_0002.pdf PDF
B09-Attachment_2_-_Revised_Final_Construction_Drawings_2026_08_18_Part1_0002.pdf PDF
B09-Attachment_2_-_Revised_Final_Construction_Drawings_2026_08_18_Part4_0002.pdf PDF
B09-140P2026R0078-Amd_2_0002.pdf PDF
B09-Attachment_2_-_Revised_Final_Construction_Drawings_2026_08_18_Part7_0002.pdf PDF
Sign_In_Sheet_Page_2_0001.jpg JPG image
B08-YELL_326141_MODULAR_HOUSING_Preproposal__0001.pdf PDF
Sol_140P2026R0078_Amd_0001.pdf PDF
Sign_In_Sheet_Page_1_0001.jpg JPG image
Sol_140P2026R0078.pdf PDF
B08-Attachment_2-01_YELL_326141_Final_CD_Plans_2026_07_22_Part6.pdf PDF
B08-YELL_326141_pre-proposal_project_overview_and_site_visit_(002).pdf PDF
B08-Attachment_1_-_02_YELL_326141_Final_Specifications_2026_07_22.pdf PDF
B08-Attachment_2-01_YELL_326141_Final_CD_Plans_2026_07_22_Part5.pdf PDF
B08-Attachment_1A-03_YELL_326141_Final_Specification_Appendicies_2026_07_22.pdf PDF
B08_Solitation-140P2026R0078_v16_17June2026.pdf PDF
E15_Deliverables_LmtOnSubconRpt_REQD.xlsx XLSX spreadsheet
B08-Attachment_2-01_YELL_326141_Final_CD_Plans_2026_07_22_Part4.pdf PDF
B08-Attachment_2-01_YELL_326141_Final_CD_Plans_2026_07_22_Part2.pdf PDF
B08-Attachment_2-01_YELL_326141_Final_CD_Plans_2026_07_22_Part1.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C

PRELIMINARY

NOT FOR

CONSTRUCTION

Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.

YELLOWSTONE NATIONAL PARK

TITLE OF SHEET

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.DESIGNED:

JC

CADD:

BB/PS/AS

TECH. REVIEW:

LF

DATE:

A/E: FIRM

PRIME:

STANTEC

CHEYENNE, WY

SHEET

OF

P

LO

T D

A

TE

R

EV

IT

V

ER

SI

O

N

198433

/1

/2

:4

:0

P M

A u to d e sk

D o c s:

Y

E

LL

N

P S /0 a rc h b d r.

rv t

SHEET INDEX & CODE

INFORMATION

326141A000

06/12/2026

ARCHITECTURAL SHEET INDEX

NO. DRAWING NAME

GENERAL

A000 SHEET INDEX & CODE INFORMATION

ARCHITECTURAL

A005B 2BR ABA DOOR & WINDOW TYPES / SCHEDULES / DETAILS

A005C 3BR DOOR TYPES / SCHEDULES / DETAILS

A005D 3BR ABA DOOR TYPES / SCHEDULES / DETAILS

A006C 3BR WINDOW TYPES / SCHEDULES / DETAILS

A006D 3BR ABA WINDOW TYPES / SCHEDULES / DETAILS

A101A 2BR FLOOR & REFLECTED CEILING PLAN

A101B 2BR ABA FLOOR & REFLECTED CEILING PLAN

A101C 3BR FLOOR PLAN

A101D 3BR ABA FLOOR PLAN

A102C 3BR REFLECTED CEILING PLAN

A102D 3BR ABA REFLECTED CEILING PLAN

A200A 2BR ELEVATIONS

A200B 2BR ABA ELEVATIONS

A200C 3BR ELEVATIONS

A200D 3BR ABA ELEVATIONS

A610B 2BR ABA INTERIOR ELEVATIONS

A610C 3BR INTERIOR ELEVATIONS

A610D 3BR ABA INTERIOR ELEVATIONS

A901B 2BR ABA RENDERINGS

A901C 3BR RENDERINGS

A901D 3BR ABA RENDERINGS

PLUMBING

9. COMPLIANCE WITH IWUIC AND THE APPLICABLE FIRE-RESISTIVE

CONSTRUCTION REQUIREMENTS OF NPS REFERENCE MANUAL 58 ARE

REQUIRED.

8. PROVIDE PROPERLY SIZED WALLS TO ALLOW DRILLING & NOTCHING

COMPLIANCE PER R 602.6.

7. ALL CONCENTRATED FRAMING LOADS TO TRANSFER TO FOUNDATION.

6. BACKWATER VALVE MAY BE REQUIRED PER UPC 710.1. PLUMBER TO

VERIFY.

5. WATER HEATER TO BE 40 GAL FOR 2 BEDROOM & 60-80 FOR 3

BEDROOM

4. WATER HEATER SEISMIC STRAPS REQUIRED PER UPC 508.2.

3. WATER HEATER TP VALVE TO TERMINATE PER UPC 608.5 & 508.5 SEE

ALSO A.R.M.

2. FLOOR DRAINS REQUIRE TRAP SEAL PROTECTION PER UPC 1007.

1. FIREBLOCKING THROUGHOUT TO COMPLY WITH R 302.11.

CODE NOTES

*Minimum Requirements Above

Crawl Space Wall R-Value

15ci or 19 or 13&5ci

15ci or 19 or 13&5ci

Floor

30 or 19&7.5ci or

20ci

Wood-Framed Wall

30 or 20&5ci or 13&10ci or 0&20ci

30 or 20&5ci or 13&10ci or 0&20ci

Insulation Entirely Above Roof Deck

49 above ceiling & below deck

30ci or 38 above ceiling and below deck

Glazed Vertical Fenestration SHGC NR NR

Vertical Fenestration (U-factor)

0.3 *0.32 shall apply above 4,000 ft

0.28 *0.30 shall apply above 4,000 ft

2021 2024

Climate Zone 6B Requirements

Architectural Barriers Act

2024 International Wildland-Urban Interface Code

2024 International Fire Code

2017 ANSI 117.1

2024 International Energy Conservation Code

2024 International Fuel Gas Code

2024 International Mechanical Code

2023 National Electric Code

2021 Uniform Plumbing Code

2024 International Residential Code

2024 International Building Code

SITE CONDITIONS AND APPLICABLE CODES MAY VARY BY

JURISDICTION. IT IS THE RESPONSIBILITY OF THE CONTRACOTR AND

MANUFACTURER TO VERIFY ALL LOCAL REQUIREMENTS PRIOR T...

THESE DRAWINGS REPRESENT A CONFORMANCE SET AND ARE

INTENDED TO ILLUSTRATE DESIGN INTENT. ALL MODULAR UNITS

MUST BE REVIEWED, APPROVED, AND STAMPED BY THE MODULAR

UNIT MANUFACTURER PRIOR TO FABRICATION AND INSTALLATION.

APPLICABLE BUILDING CODES

ARCHITECTURAL SHEET INDEX

NO. DRAWING NAME

P101A 2BR PLUMBING PLAN

P101B 2BR ABA PLUMBING PLAN

P101C 3BR PLUMBING PLAN

P101D 3BR ABA PLUMBING PLAN

ELECTRICAL

E101A 2BR ELECTRICAL PLAN

E101B 2BR ABA ELECTRICAL PLAN

E101C 3BR ELECTRICAL PLAN

E101D 3BR ABA ELECTRICAL PLAN

ARCHITECTURAL

A001 STANDARD ABBREVIATIONS, SYMBOLS, & NOTES

ARCHITECTURAL

A002 TYPICAL MOUNTING HEIGHTS

ARCHITECTURAL

A003 ASSEMBLY

ARCHITECTURAL

A005A 2BR DOOR & WINDOW TYPES / SCHEDULES / DETAILS

ARCHITECTURAL

A610A 2BR INTERIOR ELEVATIONS

ARCHITECTURAL

A901A 2BR RENDERINGS

06/18/2026

A802

1 SIM

DETAIL NUMBER

SHEET ON WHICH

DETAIL IS SHOWN

A101

A1

DETAIL CALLOUTS

EXTERIOR ELEVATIONS

ELEVATION NUMBER

SHEET ON WHICH

ELEVATION IS SHOWN

A101

1 Ref

R ef

1 Ref

R ef

INTERIOR ELEVATIONS

ELEVATION NUMBER

SHEET ON WHICH

ELEVATION IS SHOWN

A909

SIM

1_______ BUILDING SECTIONS

SECTION NUMBER

SHEET ON WHICH

SECTION IS SHOWN

A909

SIM

1_______

A909

SIM

1_______ WALL SECTIONS

SECTION NUMBER

SHEET ON WHICH

SECTION IS SHOWN

FLOOR

0'-0"

FLOOR OR ROOF LEVEL NAME

VERTICAL ELEVATION

NORTH ARROW

1 DRAWING REVISION

A101

1 Ref

PROJECT

NORTH

MATCH LINE

TRUE

NORTH

GENERAL SYMBOLS LEGEND

A

B

C

PRELIMINARY

NOT FOR

CONSTRUCTION

Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.

YELLOWSTONE NATIONAL PARK

TITLE OF SHEET

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.DESIGNED:

JC

CADD:

BB/PS/AS

TECH. REVIEW:

LF

DATE:

A/E: FIRM

PRIME:

STANTEC

CHEYENNE, WY

SHEET

OF

P

LO

T D

A

TE

R

EV

IT

V

ER

SI

O

N

198433

/1

/2

:4

:0

P M

A u to d e sk

D o c s:

Y

E

LL

N

P S /0 a rc h b d r.

rv t

STANDARD

ABBREVIATIONS,

SYMBOLS, & NOTES

326141A001

06/12/2026

Abbreviations

ADJ ADJACENT/ADJUSTABLE

AFF ABOVE FINISH FLOOR

AFG ABOVE FINISH GRADE

AHU AIR HANDLING UNIT

ALT ALTERNATE NO.

ALUM ALUMINUM

ANOD ANODIZED

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

APPD APPROVED

APPROX APPROXIMATELY

ARCH ARCHITECT

ASSY ASSEMBLY

AUTO AUTOMATIC/AUTOMATION

AVG AVERAGE

AWI AMERICAN WOODWORKING INSTITUTE

B/B BACK TO BACK

BD BOARD

BLDG BUILDING

BLKG BLOCKING

BOT BOTTOM

BSMT BASEMENT

BTWN BETWEEN

C / C CENTER TO CENTER

CAB CABINET

CBB CEMEMTITOUS BACKER BOARD

CEM CEMENT

CER CERAMIC

CF CUBIC FOOT / FEET

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED

CFLG COUNTER FLASHING

CFMF COLD FORMED METAL FRAMING

CG CORNER GUARD

CIP CAST IN PLACE

CJ CONTROL JOINT / CONSTRUCTION JOINT

CL CENTERLINE

CLG CEILING

CLO CLOSET

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CONC CONCRETE

COND CONDITION

CONST CONSTRUCTION

CONT CONTINUE / CONTINUATION / CONTINUOUS

CONTR CONTRACTOR

COORD COORDINATE

COP COPING

CPT CARPET

CT CERAMIC TILE

CTR CENTER

CU FT CUBIC FOOT / CUBIC FEET

CU YD CUBIC YARDS

CW COLD WATER

D DEPTH / DEEP

DBL DOUBLE

DEG DEGREE

DEL DELETE

DEMO DEMOLITION

DET DETAIL

DETN DETENTION

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DMPF DAMPPROOFING

DN DOWN

DR DOOR / DRAIN

DS DOWNSPOUT

DTL DETAIL

DWG DRAWING

E EAST

EA EACH

EIFS EXTERIOR INSULATION FINISH SYSTEM

EJ EXPANSION JOINT

EL REFERENCE ELEVATION

ELEC ELECTRIC / ELECTRICAL

ELEV ELEVATOR / ELEVATION

EMER EMERGENCY

ENCL ENCLOSURE

ENGR ENGINEER / ENGINEERING

EPDM ETHYLENE PROPYLENE DIENE MONOMOR

EQ EQUAL

EQL SP EQUALLY SPACED

EQUIP EQUIPMENT

EST ESTIMATE

ETC ET CETERA

EW EACH WAY

EXIST EXISTING

EXP EXPOSED / EXPAND / EXPANSION

EXT EXTERIOR / EXTERNAL / EXTINGUISHER

F / F FACE TO FACE

F F EL FINISHED FLOOR ELEVATION

FA FIRE ALARM / FACE AREA / FRESH AREA

FACP FIRE ALARM CONTROL PANEL

FD FLOOR DRAIN

FDTN FOUNDATION

Abbreviations

FDV FIRE DEPARTMENT VALVE CABINET

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FIN FINISH

FIN GR FINISHED GRADE

FIXT FIXTURE

FL FLOW LINE / FLOOR LINE

FLR FLOOR / FLOORING

FRT FRAME / FIRE RATED / FIRE RETARDANT

FT FOOT / FEET / FIRE TREATED / FULLY TEMPERED

FTG FOOTING

FURG FURRING

FURN FURNISH / FURNITURE

FUT FUTURE

GA GAGE

GAL GALLONS

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERAL / GENERATOR

GI GALVANIZED IRON

GL GLASS / GROUND LEVEL

GLZ GLAZING

GND GROUND

GYP BD GYPSUM BOARD

GYP SHTG GYPSUM SHEATHING BOARD.

HDW HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HT HEIGHT

HVAC HEATING VENTILATION AND AIR CONDITIONING

HW HOT WATER

HWH HOT WATER HEATER

IF INSIDE FACE / INTAKE FAN

IN INCHES

INCL INCLUDING

INSTL INSTALL

INSUL INSULATE / INSULATION

INT INTERIOR / INTERNAL

J BOX JUNCTION BOX

JAN JANITOR

JAN CLO JANITOR CLOSET

JT JOINT

KIT KITCHEN

LAB LABORATORY

LAM LAMINATE

LAV LAVATORY

LBS POUNDS

LF LINEAR FEET

LPT LOW POINT

LT LIGHT

LTG LIGHTING

MAINT MAINTENANCE

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MED MEDIUM

MEMB MEMBRANE

MFG MANUFACTURING

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MOD BIT MODIFIED BITUMEN

MR MOISTURE RESISTANT

MTD MOUNTED

MTL METAL

N NORTH

N/A NOT APPLICABLE

NCOMBL NONCOMBUSTIBLE

NEG NEGATIVE

NIC NOT IN CONTACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

O/O OUT TO OUT

OA OVERALL / OUTSIDE AIR

OC ON CENTER

OD OUTSIDE DIAMETER / OUTSIDE DIMENSION

OF OUTSIDE FACE

OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED

OF/OI OWNER FURNISHED/OWNER INSTALLED

OH OPPOSITE HAND / OVERHEAD / OVERHANG

OPNG OPENING

OPP OPPOSITE

ORD OVERFLOW ROOF DRAIN

ORIG ORIGINAL

ORS OVERFLOW ROOF SCUPPER

PAT PATTERN

PBD PARTICLE BOARD

PCC PRECAST CONCRETE

PERF PERFORATED

PERM PERMANENT

PL PLATE / PROPERTY LINE

PLAM PLASTIC LAMINATE

PLAS PLASTER / PLASTIC

Abbreviations

PLBG PLUMBING

PLYWD PLYWOOD

PNL PANEL

POL POLISHED

PR PAIR / PIPE RAIL

PREFAB PREFABRICATED

PREFIN PREFINISHED

PRELIM PRELIMINARY

PREP PREPARATION

PROJ PROJECT

PT PAINT / PRESSURE TREATED

PT CONC POST TENSION CONCRETE

PTD PAINTED / PAPER TOWEL DISPENSER

PTN PARTITION

PVC POLYVINYL CHLORIDE

QTY QUANTITY

R RADIUS / RISER

RA RETURN AIR

RB RUBBER BASE / RESILIENT BASE

RBR RUBBER

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REBAR REINFORCED STEEL BAR

REC RECESSED

REF REFERENCE / REFRIGERATOR

REINF REINFORCED / REINFORCEMENT

REM REMOVE

REQD REQUIRED

REV REVISION

RGD INS RIGID INSULATION

RLG RAILING

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

RP REFERENCE POINT

RTG RATING

RVL REVEAL

S SOUTH

SALV SALVAGE

SAN SANITARY

SCHED SCHEDULE / SCHEDULED

SCHEM SCHEMATIC

SCWD SOLID CORE WOOD DOOR

SEC SECOND

SECT SECTION

SF SQUARE FOOT / SQUARE FEET / SUPPLY FAN

SGL SINGLE

SHT SHEET

SHT MTL FLASH SHEET METAL FLASHING

SHTHG SHEATHING

SIM SIMILAR

SLNT SEALANT

SM SHEET METAL / SMALL / SURFACE MOUNTED

SMACNA SHEET METAL AIR CONDITIONING CONTRACTOR'S NATIONAL

ASSOCIATION

SPEC SPECIFICATION(S)

SPLY SUPPLY

SPRT SUPPORT

SQ SQUARE

SST STAINLESS STEEL

STC SOUND TRANSMISSION CLASS

STD STANDARD

STL STEEL

STL JST STEEL JOIST

STOR STORAGE

STRUC STRUCTURAL

SURF SURFACE

SUSP SUSPENDED

SYMM SYMMETRICAL

T&B TOP AND BOTTOM

TBD TO BE DETERMINED

TEL TELEPHONE

TEMP TEMPERATURE / TEMPORARY

THK THICK / THICKNESS

THRES THRESHOLD

THRU THROUGH

TO TOP OF ____

TOC TOP OF CONCRETE / TOP OF CURB

TOJ TOP OF JOIST

TOW TOP OF WALL

TRTD TREATED

TS TUBE STEEL

TYP TYPICAL

UL UNDERWRITER'S LABORATORIES

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

UTIL UTILITY

VAR VARIES

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VNR VENEER

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

Abbreviations

W WEST / WIDTH / WIDE

W/ WITH

W/O WITHOUT

WBL WOOD BLOCKING

WC WATER CLOSET / WALL COVERING

WD WOOD / WOOD DOOR

WDW WINDOW

WF WIDE FLANGE

WH WATER HEATER

WP WATERPROOFING / WORKING POINT

WR WATER RESISTANT / WEATHER RESISTANT

WT WEIGHT

YD YARD / YARDS

ALL EXTERIOR WALLS TO BE 2X6 STUDS AT 16" o/c TYPICAL. ALL WALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHAPTER 6 OF 2021 IRC CODE. INTERIOR WALLS TO BE 2X4 AT 16" o/c

UNLESS NOTED OTHERWISE. ALL WALLS TO MEET MIN. IECC 2021 INSULATION.

ALL FINISH MATERIALS SHALL CONFORM TO IBC & IRC FOR FLAME SPREAD AND SMOKE

DEVELOPMENT, REFER TO SPECIFIC MATERIAL SPECIFICATION SECTIONS AND FINISH SCHEDULE

FOR ADDITIONAL REQUIREMENTS. CONTRACTOR TO BE FAMILIAR WITH REQUIREMENTS AND

PROVIDE DOCUMENTATION WITH MATERIAL SUBMITTALS FOR REVIEW.

FOR THE PURPOSE OF PRICING/ESTIMATES, WHEN THERE IS A CONFLICT/DISCREPANCY IN THE

DRAWINGS AND/OR SPECIFICATIONS, THE CONTRACTOR SHALL PRICE THE HIGHER COST ITEM.

THE CONTRACTOR SHALL MAINTAIN A CURRENT/UPDATED RECORD OF DRAWINGS ON SITE AT

ALL TIMES.

EACH INSTALLER SHALL EXAMINE THE SUBSTRATE CONDITION AND/OR SITE CONDITIONS WHICH AFFECT THE QUALITY OF EACH PRODUCT TO BE INSTALLED. IF ANY CONDITIONS EXIST WHICH WILL HAVE A DETRIMENTAL EFFECT ON THE QUALITY OF THE INSTALLATION, THE INSTALLER SHALL

IMMEDIATELY ADVISE THE CONTRACTOR. INSTALLATION SHALL NOT PROCEED UNTIL THE

UNSATISFACTORY CONDITIONS ARE CORRECTED. INSTALLATION OF PRODUCTS SHALL SIGNIFY

ACCEPTANCE BY THE INSTALLER OF THE SUBSTRATE CONDITIONS.

THE CONTRACTOR SHALL BECOME FAMILIAR WITH AND COMPLY WITH OWNER’S PROCEDURES

FOR MAINTAINING A SECURE SITE AND BUILDING.

THE CONTRACTOR SHALL PROMPTLY REMOVE AND PROPERLY DISPOSE OF ALL CONSTRUCTION

AND DEMOLITION DEBRIS. THE CONTRACTOR SHALL OBTAIN APPROVAL OF OWNER FOR DETAILS

RELATED TO ALL SITE ACCESS AND REMOVAL PLANS.

THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR MEANS, METHODS AND SEQUENCES OF

CONSTRUCTION.

THE CONTRACTOR SHALL PROVIDE AND COORDINATE ALL BLOCK-OUTS, SLEEVES, INSERTS,

BOLTS, PLATES, ETC. FOR ALL TRADES PRIOR TO PLACING CONCRETE.

THE DRAWINGS SHALL NOT BE REPRODUCED FOR SUBMITTALS. DRAWINGS OR PORTIONS

THEREOF USED FOR SUBMITTALS WILL BE REJECTED AND RETURNED TO THE CONTRACTOR

WITHOUT THE APPROVAL OF THE ARCHITECT.

9 THE CONTRACTOR SHALL COORDINATE ALL WORK WITH APPLICABLE UTILITY PROVIDERS.

THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND SIMILAR RELEASES REQUIRED FOR

THE CONSTRUCTION AND OCCUPANCY OF THE PROJECT. THE CONTRACTOR SHALL FURNISH

COPIES OF ALL SUCH ITEMS TO THE OWNER AND ARCHITECT WITHIN 10 DAYS OF RECEIPT OF

SUCH ITEMS. IF PERMITS ARE ISSUED SUBJECT TO CERTAIN CONDITIONS OR REVISIONS TO THE

WORK OR IF PERMITS ARE DELAYED FOR ANY REASON, THE CONTRACTOR SHALL IMMEDIATELY

NOTIFY THE OWNER AND ARCHITECT.

THE CONTRACTOR IS RESPONSIBLE TO UNDERSTAND AND COMPLY WITH ALL APPLICABLE LAWS,

CODES, REGULATIONS AND ORDINANCES OF THE PLACE (CITY, COUNTY,DISTRICT, AND STATE)

WHERE THE PROJECT IS LOCATED.

THE DRAWINGS MAY MAKE REFERENCE TO AND/OR ILLUSTRATE ITEMS WHICH ARE NOT PART OF

THE WORK OF THE CONTRACT. THESE ‘NOT IN CONTRACT’ ITEMS AS INDICATED ARE REFERENCED

AND/OR ILLUSTRATED FOR THE CONTRACTORS REFERENCE, INFORMATION AND COORDINATION

ONLY.

THE CONTRACTOR SHALL IDENTIFY AND NOTIFY IN WRITING TO THE ARCHITECT CONFLICTS

BETWEEN THE WORK OF DIFFERENT PARTIES, AND DISCREPANCIES BETWEEN THE DOCUMENTS

AND THE ACTUAL CONDITIONS AT THE EARLIEST POSSIBLE DATE SO AS TO ALLOW REASONABLE

AND ADEQUATE TIME FOR THE CONFLICT TO BE RESOLVED WITHOUT DELAYING THE WORK. ALL

DEVIATIONS FROM THAT WHICH IS REQUIRED BY THE CONTRACT DOCUMENTS MUST BE

APPROVED IN ADVANCE BY THE ARCHITECT AND OWNER PRIOR TO PROCEEDING.

THE DRAWINGS AND SPECIFICATIONS ESTABLISH MINIMUM REQUIREMENTS FOR THE DESIGN AND

CONSTRUCTION OF THE PROJECT.

THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY THE

WORK DESCRIBED ON DRAWINGS OF ANOTHER DISCIPLINE AND MAY REQUIRE CROSS

REFERENCE. PARTIAL SETS OF DRAWINGS ARE INCOMPLETE AND SHOULD NOT BE DISTRIBUTED OR

UTILIZED BY THE CONTRACTOR.

IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF ALL

SUB-CONTRACTORS, TRADES AND SUPPLIERS WITH REQUIREMENTS OF THE CONTRACT BEFORE

COMMENCING CONSTRUCTION, AND ASSURE THAT ALL PARTIES ARE AWARE OF ALL

REQUIREMNTS, REGARDLESS OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT

DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF THAT PARTY.

THE FOLLOWING GENERAL NOTES APPLY TO THE ENTIRE SET OF DRAWINGS AND ARE NOT

SPECIFIC TO ANY ONE DISCIPLINE.

GENERAL NOTES

F10

FIRE EXTINGUISHER LOCATIONS TO BE PROVIDED PER IBC/IFC AND NFPA 10.

EXTINGUISHERS WITHIN MODULAR UNITS BY MODULAR MANUFACTURER.

F9

120 VOLT COMBO PHOTO ELECTRIC SMOKE/CARBON MONOZICE

DETECTORS WITH BATTERY BACK UP, INTER-TIED SO THAT ACTIVATION OF A

SINGLE DETECTOR CAUSES ALL DETECTORS TO GO INTO ALARM. ALL

EQUIPMENT TO BE RATED TO MEET NFPA 72.

F8

SUBMIT FIRE SUPRESSION DESIGN FOR CO APPROVAL. FIRE SUPPRESSION

DESIGN SHALL BE REVIEWED BY THE NPS REGIONAL STRUCTURAL FIRE...

F7

INTERIOR SPINKLER SYSTEM TO COMPLY WITH NFPA 13D STANDARD FOR THE

INSTALLATION OF SPRINKLER SYSTEMS IN ONE- AND TWO- FAMILY DWELLING

AND MANUFACTURED HOMES.

F6

NICET II MIN. FOR THE INSTALLATION OF AUTOMATIC SPRINKLER SYSTEMS.

NICET III MIN. FOR PROJECT OVERSIGHT NICET IV FOR SPRINKLER DESIGN.

F5

FIRE ALARM IS THE BE INSTALLED TO NFPA 72 AND NFPA 70 (NEC), AS 120V,9V

SMOKE DETECTORS WITH A 120V EXTERIOR HORN STROBE; DETECTORS TO BE

INTERCONNECTED.

F4

SPRINKLERS MADE OF CROSS-LINKED POLYETHYLENE PIPE(PEX OR EQUAL) TO

BE ALLOWED IN CEILINGS AS LONG AS ALL APPLICABLE CODES ARE MET.

F3 FIRE SUPPRESSION SYSTEMS SHALL BE DESIGNED TO MEET NFPA 13D.

F2

THE CONTRACTOR IS RESPONSIBLE FOR CONTRACTING AND

COORDINATING FIRE ALARM AND SUPRESSION SUBS TO ENSURE

COMPLIANCE WITH LATEST BUILDING CODE.

F1

FIRE SUPPRESSION SYSTEMS SHALL BE PROVIDED BY THE MODULAR BUILDING

MANUFACTURER AND SHALL BE DESIGNED IN ACCORDANCE WITH THE

REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) AND

NPS REFERENCE MANUAL 58 REQUIREMENTS.

FIRE SUPPRESSION & DETECTION

P5

WATER HEATERS TO BE ELECTIC & A 50 GALLON MIN. FOR ALL TWO

BEDROOM MODULES & A 66 GALLON MIN. FOR ALL THREE BEDROOM

MODULES.

P4

ALL FAUCETS AND BARS TO BE SATIN NICKEL UNO. ALL TOILETS TO BE

ELONGATED UNO. ALL KITCHEN SINKS TO BE UNDER-COUNTER MOUNTED

STAINLLESS STEEL UNO.

P3

WINTERIZATION DRAIN LOCATED IN THE CRAWL SPACE AND DRAINED TO THE

EXTERIOR OF THE MODULAR BUILDING PAST THE FOUNDATION WALL WITH AN

EXTERIOR FROST FREE VALVE. ALL WATER PIPING TO BE DESIGNED FOR UNITS

TO BE FULLY DRAINED FOR WINTERIZATION.

P2

ALL PLUMBING TO CONFORM TO U.P.C. (2021 EDITION) AND HIGHEST

STANDARDS OF THE TRADE. ALL WATER LINES TO BE COPPER OR PLASTIC AND

ALL SEWER LINES TO BE MIN. SCH 40 PVC. GAS LINES SHALL BE BLACK IRON

PER CODE. FIXTURES LOCATIONS SHALL BE INCLUDED IN SHOP DRAWINGS

AND SHALL BE SPECIFIED AND INSTALLED BY MODULAR BUILDING

MANUFACTURER. PLUMBING CONTRACTOR TO OBTAIN ALL NECESSARY

PERMITS. PLUMBER SHALL VERIFY LOCATION TO SEWER AND WATER MAINS

AND MAKE SERVICE CONNECTIONS AS REQUIRED. BURIED WATER SERVICE

TO BE HDPE PIPE.

P1

PLUMBING SYSTEMS SHALL BE PROVIDED BY THE MODULAR BUILDING

MANUFACTURER AND SHALL MEET ALL APPLICABLE LOCAL CODES AND GSA

REQUIREMENTS.

PLUMBING

E5 ALL INTERIOR LIGHTING TO BE LIGHT EMITTING DIODE (LED) U.N.O.

E4

EXTERIOR LIGHTING TO BE FULLY SHIELDED, MAX 2 FOOT CANDLES, 3,000K

MAX.(LED).

E3

NIGHT SKY: PROJECT SHALL COMPLY WITH NPS AND PARK LIGHTING

GUIDLINES TO REDUCE IMPACTS TO THE NIGHT SKY AND WILDLIFE. THIS WILL

INCLUDE, BUT IS NOT LIMITED TO, LOW-LEVEL LIGHTING, MINIMIZED GLARE,

DOWNWARD FOCUSED LIGHT FIXTURES, AND ENERGY EFFICIENT LIGHT

SOURCES SUCH AS LOW-PRESSURE SODIUM LAMPS.

E2

ALL ELECTRICAL SHALL CONFORM TO N.E.C (2023 EDITION) AND ALL

APPLICABLE STATE CODES. ALL SERVICES SHALL BE COPPER AND ALL WIRING

TO BE MIN. 14-2 COPPER W/ GRD. ELEC. CONTRACTOR SHALL OBTAIN

NECESSARY STATE PERMITS. FIXTURES SHALL BE SPECIFIED AND INSTALLED BY

MODULAR BUILDING MANUFACTURER, AS APPROVED THROUGH SHOP

DRAWINGS.

E1

ELECTRICAL SYSTEMS SHALL BE PROVIDED BY THE MODULAR BUILDING

MANUFACTURER AND SHALL CONFORM TO ALL APPLICABLE LOCAL

JURISDICTIONAL CODES AND GSA STANDARDS.

ELECTRICAL

M5 WOOD STOVE TO BE EPA COMPLIANT

M4

THERMOSTAT CONTROL FOR ALL COVE STYLE HEATING TO BE PROVIDE IN

EACH ROOM. LOCATIONS SHALL BE INCLUDED IN SHOP DRAWINGS.

M3

HEATING SHALL BE INSTALLED BY CERTIFIED HEATING CONTRACTOR AND

SHALL BE OF TYPE SPECIFIED AND INSTALLED BY MODULAR BUILDING

MANUFACTURER. SHOP DRAWINGS SHALL INCLUDE LOCATIONS OF ALL

HEAT REGISTERS AND RETURNS.

M2

THE CONTRACTOR SHALL COORDINATE ALL MECHANICAL CHASE SIZES WITH

MECHANICAL SUB-CONTRACTOR AND NOTIFY ARCHITECT WITH

DISCREPANCIES IN THE FIELD.

M1

MECHANICAL SYSTEMS SHALL BE PROVIDED BY THE MODULAR BUILDING

MANUFACTURER & SHALL COMPLY WITH ALL APPLICABLE LOCAL CODES

AND GSA REQUIREMENTS.

MECHANICAL

DISCIPLINE NOTES

30" MIN CLR

M

A X

(B) 10"-24"

(A) 0" TO 20"

M

IN

M

A X

4" MAX

(B

M

A X

(A

M

A X

(B) 20" TO 25" MAX

M

IN

11" MIN6" MAX

8" MIN

M

IN

M

IN

12" MAX 42" MIN

39" MIN TO 41" MAX

M

IN

T

O

M A

X

M

IN

T

O

M A

X

M

IN

54" MIN

M

IN

12" MIN24" MIN

M

IN

T

O

M A

X

36" MIN

24" MIN

42" MAX

36" MAX

M

A X

M

IN

/2

M

IN

M

IN 6"

3'-0"

M

IN

60" MIN

60" MIN

M

IN

6" MAX

15" MAX

M

A X

A B

O V

E G

R A

B B

A R

5'-0"

M

IN

M

A X

M

A X

A B

O V

E G

R A

B B

A R

27" MAX

16" MIN

M A

X

(A) 0" TO 10" MAX

(B

M

A X

(A

M

A X

M

IN

H G

T O

F L

A V

/S

IN

K S

M

A X

2 1/2" MAX

/2

M A

X

M A

X

15" MIN - 16" MAX

22" MIN - 23" MAX

A

F F

4" 4"

UNLIMITED

UNLIMITED

UNLIMITED

1'-2"4" 4"

M

IN

T

O

M A

X

12" MIN

TOE CLEARANCES [306.2]

KNEE CLEARANCES [306.3]

HEIGHT OF LAVS/SINKS [606.3]

REACH RANGES [308]

PROTRUDING OBJECTS [307]

CIRCULATION

AISLE

TOE CLEARANCE

KNEE CLEARANCE

MAX REACH HEIGHT

OBSTRUCTION

LIMITS

MIN REACH HEIGHT

IF UNOBSTRUCTED

INCLUDING BUT

NOT LIMITED TO

OUTLETS AND

JUNCTION BOXES

(TYP.)

INCLUDING BUT

NOT LIMITED TO

HIGH OUTLETS,

INTERCOMS,

THERMOSTATS,

FIRE ALARM PULL,

CARD READERS,

ARMING

STATIONS

BATHROOM

HEIGHT

PROTRUDING

DISPENSER (DARK GREY)

RECESSED DISPENSER

(DASHED)

WHEELCHAIR ACCESSIBLE COMPARTMENT GRAB BAR AND

DISPENSER LOCATION

TRANSFER-TYPE SHOWER COMPARTMENT SIZE AND

CLEARANCE(CONTROL WALL)

SHOWER

CONTROL

AND

HANDSHOWER

LOCATION

MIN SIDE REACH IF

UNOBSTRUCTED

MAX SIDE REACH

MAX HEIGHT OF

SIDE OBSTRUCTION

TOE

CLEARANCE

WATER CLOSET AND TOILET COMPARTMENTS [604] SHOWER COMPARTMENTS [608] L SHAPE SHOWER COMPARTMENT SEAT [610]

(B) L-SHAPED SEAT

(A) RECTANGLE SEAT

FOLDING

SHOWER

SEAT

ACCESSIBLE FORWARD REACH RANGES AND CLEARANCES

DIAGRAM (SIDE VIEW)

ACCESSIBLE SIDE REACH RANGES AND CLEARANCES

DIAGRAM (SIDE VIEW)

ACCESSIBLE FORWARD REACH CLEARANCES DIAGRAM (PLAN

VIEW)

L-SHAPED SHOWER COMPARTMENT

CONTROL WALL

LOCKER

NOTE: AT LEAST

5% (NOT LESS

THAN 1) LOCKERS

SHALL BE

ACCESSIBLE.

PROVIDE 30"X48"

CLEAR SPACE

FOR PARALLEL

APPROACH.

TYPICAL ACCESSIBLE FIXTURE

HEIGHTS DIAGRAM

NOTE: OPERABLE PARTS SHALL BE

OPERABLE WITH ONE HAND AND

SHALL NOT REQURE TIGHT

GRASPING,

PINCHING OR TWISTING OF THE

WRIST. THE FORCE REQUIRED SHALL

BE 5LB MAX.

GRAB HEIGHT

NOTE: OPERABLE PARTS SHALL BE OPERABLE WITH

ONE HAND AND SHALL NOT REQURE TIGHT

GRASPING,

PINCHING OR TWISTING OF THE WRIST. THE FORCE

REQUIRED SHALL BE 5LB MAX.

OPERABLE PARTS [309.4]

ACCESSIBLE

ROBE HOOK

WHEELCHAIR ACCESSIBLE COMPARTMENT GRAB BAR/TOILET

LOCATION AND CLEARANCE

OPERABLE PARTS [309.4]

LIMITS OF PROTRUDING OBJECTS DIAGRAM

(SIDE VIEW)

PROTRUDING OBJECTS [307]

REDUCED VERTICAL CLEARANCE DIAGRAM (SIDE VIEW)

REACH RANGES [308]

SHOWER COMPARTMENTS [608]

ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE

DIAGRAM (PLAN VIEW)

SHOWER COMPARTMENTS [608]

LIGHT

SWITCH

DUPLEX

OUTLET

(TYP.)

DUPLEX

OUTLET

(HIGH)

DESK

INTERCOM

OUTLET

TELEPHONE

OR DATA

OUTLET

THERMOSTAT

OR FIRE ALARM

SPECIAL

PURPOSE

OUTLETS

SPECIAL

PURPOSE

OUTLETS

JUNCTION

BOX

SWITCH AT

DOOR OR CASED

OPENING

AUDIBLE &

VISUAL FIRE

ALARM

SECURITY

STROBE LIGHT

(BLUE LIGHT)

ELECTRICAL PANEL

BOARD

(RECESSED)

FIXED SHOWER

HEAD

FLEXIBLE 60"

SHOWER SPRAY

HOSE

FLEXIBLE 60"

BATHTUB SPRAY

HOSE

SINGLE LEVER

SHOWER MIXING

VALVE

RECESSED

SHOWER STALL

SOAP DISH

ACCESSIBLE

ROBE HOOK

GRAB BARS IN ACCESSIBLE

SHOWER (CONTROL WALL)

SHOWER CURTAIN

ROD

ACCESSIBLE

SHOWER PLAN

NOTE: CA REQUIREMENT

ACCESSIBLE SINK PLAN ACCESSIBLE LAVATORY HC W.C. ACCESSIBLE WATER

CLOSET (SIDE VIEW)

DRINKING FOUNTAIN OR WATER

COOLER (SIDE VIEW) THRESHOLD ON ACCESSIBLE

PATH

M

IN

L O

W R

E A

C H

M A

X F

O R

W A

R D

R E

A C

H

1' -6

M A

X F

O R

W A

R D

R E

A C

H

3'-0"

4' -0

5' -0

5' -0

2' -0

M

T G

B R

A C

K E

T

3' -2

B

O T

O F

M T

G B

R A

C K

E T

4' -0

T

O P

O F

M T

G B

R A

C K

E T

3' -4

3' -4

4' -0

3'-0"

3' -0

MIN

5'-0"

FOLDING SHOWER SEAT

SLOPE TO DRAIN 1/2"

PER FOOT MAX.

SHOWER GRAB BARS

M A

X

1' -7

2'-6"

4' -0

8" MIN

6" MAX

9" M

IN

2' -5

M

IN

C

LR

3' -4

M

A X

2' -1

0" M

A X

T O

R

IM

LAVATORIES ADJ TO A WALL SHALL BE

MOUNTED 18" MIN (OR GREATER AS

INDICATED ON PLANS) FROM ADJ WALL TO

CENTERLINE OF FIXTURE.

1' -5

WATER CLOSETS SHALL BE MOUNTED 18"

FROM ADJACENT WALL OR TOILET PARTITION

TO CENTERLINE OF FIXTURE.

1' -5

T

Y P

1'-5" TO 1'-7"

8" MIN

6" MAX

2' -3

M

IN

9" M

IN

1/ 4"

M A

X

1/ 2"

M A

X

5' -0

WALL MOUNTED FE COAT HOOKS (WALL-

MTD)

COAT HOOKS

(DOOR-MTD)

MIRROR

(WALL MOUNT)

MIRROR ABOVE COUNTER

3'-0"

1'-8"

4' -0

SEE PLAN

2' -6

4"

4"

3' -0

M

IN

F

O R

C O

N T

R O

LS

24" MAX

M

IN

C

LR

5' -0

18" MIN

CLR

32" MIN,

SINGLE OCCUPANCY TOILET

MIN

1'-6"

MAX. 12" ENCROACHMENT WITH A MIN. 67" LANDING FOR DOORS

THAT SWINGS INWARD; MAX 10" OVERLAP OF KNEE AND TOE

4' -0

3' -9

CLEAR FLOOR SPACE REQUIREMENTS

BOTTOM OF

MIRROR

1' -0

M

IN

6' -0

M

A X

M A

X S

ID

E

R E

A C

H

M

A X

S

ID

E R

E A

C H

M

IN

L O

W R

E A

C H

M

IN

. F O

R C

O N

T R

O L

M

IN

L O

W R

E A

C H

M A

X F

O R

W A

R D

R E

A C

H

M A

X S

ID

E

R E

A C

H

3'-4"

MAX

12"

42"

36" 6"

TOILET TISSUE

DISPENSER

M A

X

CLEAR WIDTH AT 180° TURNA

T-SHAPED TURNING SPACE

C

(6

M

IN

M

IN

(36" MIN)

3'-6" MIN

(36" MIN)

3'-6" MIN

1'-0" MIN 3'-0" MIN 1'-0" MIN

M

IN

M

IN 5

M

IN

5'-0" MIN

THE SPACE SHALL

BE PERMITTED TO

INCLUDE KNEE AND

TOE CLEARANCE

ONLY AT THE END

OF EITHER THE

BASE OR ONE ARM.

THE SPACE

SHALL BE

PERMITTED TO

INCLUDE KNEE

AND TOE

CLEARANCE.

CIRCULAR TURNING SPACE

B

WHEEL CHAIR TURNING SPACE AND TOE AND KNEE CLEARANCES

A

B

C

PRELIMINARY

NOT FOR

CONSTRUCTION

Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.

YELLOWSTONE NATIONAL PARK

TITLE OF SHEET

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.DESIGNED:

JC

CADD:

BB/PS/AS

TECH. REVIEW:

LF

DATE:

A/E: FIRM

PRIME:

STANTEC

CHEYENNE, WY

SHEET

OF

P

LO

T D

A

TE

R

E V

IT

V

E R

SI

O

N

198433

:4

:0

P M

A u to d e sk

D o c s:

Y

E L L N

P S /0 a rc h b d r.

rv t

TYPICAL MOUNTING

HEIGHTS

326141A002

06/12/202606/18/2026

CONTINUOUS METAL

RIDGE VENT

STANDING SEAM METAL ROOF; RE:

SECTION 07 41 13.16 STANDING METAL

ROOF PANELS

UNDERLAYMENT; RE:

SECTION 07 41 13.16 STANDING METAL

ROOF PANELS

SHEATHING; RE:

SECTION 06 16 00 SHEATHING

PREFINISHED FLEXIBLE METAL

FLASHING

VENTILATED SOFFIT; RE:

SECTION 07 46 46 FIBER-CEMENT

SIDING

FIBER CEMENT SIDING; RE:

SECTION 07 46 46 FIBER-CEMENT

SIDING

1/2 GLASS MAT GYPSUM RE;

SECTION 06 16 00 SHEATHING

GYPSUM BOARD CEILING

SUBFLOOR DECKING

WOOD TRIM

CAST IN PLACE CONCRETE; RE:

STRUCTURAL

MANUF. STANDARD SIDING STARTER

STRIP

SPRAY FOAM INSULATION;

RE: A000 FOR R-VALUES;

INSPECT UPON DELIVERY

10 MIL MIN. VAPOR

RETARDER

CONCRETE FACED INSULATION

BOARD; RE: A000 FOR R-VALUES;

CONFIRM FROST DEPTH WITH

STRUCTURAL

DRAIN TILE

GYPSUM BOARD

BATT INSULATION; RE:

A000 FOR R-VALUES

SPRAY FOAM INSULATION;

RE: A000 FOR R-VALUES;

INSPECT UPON DELIVERY

SPRAY FOAM INSULATION;

RE: A000 FOR R-VALUES;

INSPECT UPON DELIVERY

FIBERGLASS WINDOW; FLASH & SHIM

WINDOW PER MANUFACTURER

RECOMMENDATIONS

PREFINISHED FLEXIBLE METAL

FLASHING; ENSURE METAL FLASHING

DOES NO INTERRUPT CRITICAL SEALS

BETWEEN WINDOW FRAME AND ROUGH

OPENING, TYP.

PREFINISHED FLEXIBLE METAL

FLASHING; ENSURE METAL FLASHING

DOES NO INTERRUPT CRITICAL SEALS

BETWEEN WINDOW FRAME AND ROUGH

OPENING, TYP.

WOOD FRAMING

SELF-ADHESIVE MEMBRANE

RIGID INSULATION; RE: A000 FOR

R-VALUES

VAPOR RETARDER

TAPE

3" 3"

NOTE(S):

1. WHERE WOOD FRAMING CANTILEVERS CONCRETE WALL,

ADJUST METAL BASE FLASHING TO SUIT.

2. MAINTAIN FIBER CEMENT SIDING MANUFACTURER'S MIN.

CLEARANCE BETWEEN SIDING AND GRADE. SLOPE GRADE AWAY

FROM BUILDING. REGRADE AS REQUIRED.

3. INSTALL FIBER CEMENT SIDING PER MANUFACTURER'S

RECOMMENDATIONS.

4. SPACE PLANKS 1/8" (HORIZ.) MAINTAIN 3/8" MIN. EDGE DISTANCE

FROM END OF PLANKS WITH FASTENERS AND 1" FROM THE TOP

EDGE.

FURRING STRIPS WITH INSECT

SCREENS

TRIM

FILLET BEAD OF SEALANT

MINIMUM CODE REQUIRED

VENTILATION CHUTE OR FURRING

CHANNEL

FLOOR FINISH

UNDERLAYMENT; RE:

SECTION 07 41 13.16 STANDING METAL

ROOF PANELS

SHEATHING; RE:

SECTION 06 16 00 SHEATHING

WATERPROOFING/DAMPROOFING;

REFER TO MODULAR BUILDINGS

SPECIFICATION

RE: IRC FOR MIN GAP

RE: STRUCTURAL

SHIM & SEAL AS REQUIRED BY MANUF.

SHIM & SEAL AS REQUIRED BY MANUF.

FLUID-APPLIED AIR BARRIER; WEATHER

BARRIER

FLUID-APPLIED AIR BARRIER; WEATHER

BARRIER; WRAP BARRIER AS

REQUIRED BY MANUFACTURER AT

OPENINGS

R E

: C

IV

IL

8" M

IN

, T

Y P

SYSTEM COMPONENTS & FIRE RATING

REQUIREMENTS MAY VARY PER UNITS SPECIFIC

LOCATION. FIRE RESISTIVE CONTRUCTION MUST

COMPLY WITH NPS REFERENCE MANUAL 58 AND THE

IWUIC.

A

B

C

PRELIMINARY

NOT FOR

CONSTRUCTION

Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.

YELLOWSTONE NATIONAL PARK

TITLE OF SHEET

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.DESIGNED:

JC

CADD:

BB/PS/AS

TECH. REVIEW:

LF

DATE:

A/E: FIRM

PRIME:

STANTEC

CHEYENNE, WY

SHEET

OF

P

LO

T D

A

TE

R

E V

IT

V

E R

SI

O

N

198433

:4

:0

P M

A u to d e sk

D o c s:

Y

E L L N

P S /0 a rc h b d r.

rv t

ASSEMBLY

326141A003

06/12/2026

1 1/2" = 1'-0"A003

A1 EXTERIOR ASSEMBLIES

PRE-FINISHED WINDOW TRIM

WINDOW

PRE-FINISHED WINDOW TRIM

WINDOW

TYPE A1 TYPE A2 TYPE A3

A

B

C

PRELIMINARY

NOT FOR

CONSTRUCTION

Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.

YELLOWSTONE NATIONAL PARK

TITLE OF SHEET

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.DESIGNED:

JC

CADD:

BB/PS/AS

TECH. REVIEW:

LF

DATE:

A/E: FIRM

PRIME:

STANTEC

CHEYENNE, WY

SHEET

OF

P

LO

T D

A

TE

R

E V

IT

V

E R

SI

O

N

198433

:4

:0

P M

A u to d e sk

D o c s:

Y

E L L N

P S /0 a rc h b d r.

rv t

2BR DOOR & WINDOW

TYPES / SCHEDULES /

DETAILS

326141A005A

06/12/2026

DOOR SCHEDULE

NO. ROOM NAME

ROOM

NO.

DOOR FRAME

DOOR COMMENTSWIDTH HEIGHT THICK DOOR TYPE MAT'L FIN GLAZ MAT'L FINISH

LEVEL 01

A101 GREAT ROOM 3 3'-0" 6'-8" 1 3/4" Type A1 - Pre-Hung GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors

A102 MUD ROOM 10 3'-0" 6'-8" 1 3/4" Type A1 - Pre-Hung GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors

A103 MUD ROOM 10 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

A104 BATH 01 9 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

A105A BEDROOM 01 8 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

A105B BEDROOM 01 8 6'-0" 6'-8" 1 3/8" Type A3 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

A106A BEDROOM 02 2 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

A106B BEDROOM 02 2 6'-0" 6'-8" 1 3/8" Type A3 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

A106C BATH 02 5 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

A107 LAUNDRY/UTILITY 7 3'-0" 6'-8" 1 3/8" Type A2 - Pre-Hung WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

WINDOW SCHEDULE

TYPE MARK WIDTH HEIGHT MATERIAL COMMENTS

AW1 3'-0" 5'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO

RECEIVE STORM SCREEN.

AW2 3'-0" 3'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO

RECEIVE STORM SCREEN.

DOOR PANEL TYPES

WINDOW TYPES

AW1

AW2

DEADBOLT SPECIFICATIONS

SCHLAGE B SERIES GRADE 1 DEADBOLTS CORE LESS 1-3/4 SATIN

NICKEL US15 SCHB660J626

ZZ_SP-DOORHW_6929

HOT# 124572

CYLINDER CORE SPECIFICATIONS

SCHLAGE ZZ_SP-DOORHW_6932 SCH23-030E626 IC CORE CYLINDER E CORE

PROVIDE 2 BLANK KEYS

HOT# 117977

ENTRY DOOR HANDLE SPECIFICATIONS

SCHLAGE ND SERIES GRADE 1 CYLINDRICAL LOCK RHOES HANDLE ND 105

PASSAGE LATCH 1-3/4 2-3/4 SATIN NICKEL SCHND10SRHO626

ZZ_SP-DOORHW_6930

HOT# 133193

NOTE: LOCKSETS WILL REQUIRE EXTERIOR DOORS TO BE CUT TO RECEIVE COMMERCIAL LOCKSET.

DOOR HARDWARE

* ALL BEDROOMS TO RECEIVE AW1 WINDOWS IN COMPLIANCE WITH 2024 IRC SECTION R319 MINIMUMS.

AW1

NET CLEAR WIDTH: 34" - 36"

NET CLEAR OPENING HEIGHT: 32" - 34"

NET CLEAR OPENING AREA: 8.0SF - 8.5SF

IRC MINIMUMS

NET CLEAR WIDTH: 20"

NET CLEAR HEIGHT:24"

NET CLEAR OPENING AREA: 5.7SF

PRE-FINISHED WINDOW TRIM

WINDOW

TYPE B1 TYPE B2 TYPE B3 TYPE B4

A

B

C

PRELIMINARY

NOT FOR

CONSTRUCTION

Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.

YELLOWSTONE NATIONAL PARK

TITLE OF SHEET

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.DESIGNED:

JC

CADD:

BB/PS/AS

TECH. REVIEW:

LF

DATE:

A/E: FIRM

PRIME:

STANTEC

CHEYENNE, WY

SHEET

OF

P

LO

T D

A

TE

R

E V

IT

V

E R

SI

O

N

198433

:0

:1

P M

A u to d e sk

D o c s:

/1

Y

E L L N

P S a rc h b d r_ a d a .r v t

2BR ABA DOOR &

WINDOW TYPES /

SCHEDULES / DETAILS

326141A/326104A005B

05/28/25

WINDOW SCHEDULE

TYPE MARK WIDTH HEIGHT MATERIAL COMMENTS

BW1 3'-0" 5'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE

STORM SCREENS.

BW2 3'-0" 3'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE

STORM SCREENS.

DOOR SCHEDULE

NO. ROOM NAME

ROOM

NO.

DOOR FRAME

DOOR COMMENTSWIDTH HEIGHT THICK Door Type MAT'L FIN GLAZ MAT'L FINISH

LEVEL 01

B101 GREAT ROOM 6 3'-0" 6'-8" 1 3/4" TYPE B1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors

B102 MUD ROOM 3 3'-0" 6'-8" 1 3/4" TYPE B1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors

B103 MUD ROOM 3 3'-0" 6'-8" 1 3/8" TYPE B2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

B104 BATH 01 2 3'-0" 6'-8" 1 3/8" TYPE B2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

B105A BEDROOM 01 9 3'-0" 6'-8" 1 3/8" TYPE B2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

B105B BEDROOM 01 9 6'-0" 6'-8" 1 3/8" TYPE B3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

B106A BEDROOM 02 10 3'-0" 6'-8" 1 3/8" TYPE B2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

B106B BEDROOM 02 10 6'-0" 6'-8" 1 3/8" TYPE B3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

B106C BATH 02 ABA 4 3'-0" 6'-8" 1 3/8" TYPE B2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

B106D BATH 02 ABA 4 2'-6" 6'-8" 1 3/8" TYPE B4 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See Section 081416 For Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

DOOR PANEL TYPES

DEADBOLT SPECIFICATIONS

SCHLAGE B SERIES GRADE 1 DEADBOLTS CORE LESS 1-3/4 SATIN

NICKEL US15 SCHB660J626

ZZ_SP-DOORHW_6929

HOT# 124572

CYLINDER CORE SPECIFICATIONS

SCHLAGE ZZ_SP-DOORHW_6932 SCH23-030E626 IC CORE CYLINDER E CORE

PROVIDE 2 BLANK KEYS

HOT# 117977

ENTRY DOOR HANDLE SPECIFICATIONS

SCHLAGE ND SERIES GRADE 1 CYLINDRICAL LOCK RHOES HANDLE ND 105

PASSAGE LATCH 1-3/4 2-3/4 SATIN NICKEL SCHND10SRHO626

ZZ_SP-DOORHW_6930

HOT# 133193

NOTE: LOCKSETS WILL REQUIRE EXTERIOR DOORS TO BE CUT TO RECEIVE COMMERCIAL LOCKSET.

DOOR HARDWARE

BW1

BW2

WINDOW TYPES

* ALL BEDROOMS TO RECEIVE AW1 WINDOWS IN COMPLIANCE WITH 2024 IRC SECTION R319 MINIMUMS.

BW1

NET CLEAR WIDTH: 34" - 36"

NET CLEAR OPENING HEIGHT: 32" - 34"

NET CLEAR OPENING AREA: 8.0SF - 8.5SF

IRC MINIMUMS

NET CLEAR WIDTH: 20"

NET CLEAR HEIGHT:24"

TYPE C1 TYPE C3TYPE C2

B

C

PRELIMINARY

NOT FOR

CONSTRUCTION

Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.

YELLOWSTONE NATIONAL PARK

TITLE OF SHEET

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.DESIGNED:

JC

CADD:

BB/PS/AS

TECH. REVIEW:

LF

DATE:

A/E: FIRM

PRIME:

STANTEC

CHEYENNE, WY

SHEET

OF

P

LO

T D

A

TE

R

E V

IT

V

E R

SI

O

N

198433

:2

:3

P M

A u to d e sk

D o c s:

Y

E L L N

P S /0 a rc h b d r.

rv t

3BR DOOR TYPES /

SCHEDULES / DETAILS

326141A005C

06/12/2026

DOOR SCHEDULE

NO. ROOM NAME

ROOM

NO.

DOOR FRAME

DOOR COMMENTSWIDTH HEIGHT THICK TYPE MAT'L FIN GLAZ MAT'L FINISH

LEVEL 01

C101A FOYER 1 3'-0" 6'-8" 1 3/4" TYPE C1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors

C101B FOYER 1 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

C103 HALL 3 4'-0" 6'-8" 1 3/8" TYPE C3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

C104A BEDROOM 02 4 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

C104B BEDROOM 02 4 4'-0" 6'-8" 1 3/8" TYPE C3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

C106A LAUNDRY 6 3'-0" 6'-8" 1 3/4" TYPE C1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; 60 Min Fire. Solid core door, code-compliant hardware, including gasketing, spring hinge / self-closing; Contracting officer to select from manufacturer's standard colors, Spring Hinge, Seals

C106B LAUNDRY 6 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

C107A BEDROOM 03 7 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

C107B BEDROOM 03 7 4'-0" 6'-8" 1 3/8" TYPE C3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

C108 BATH 02 8 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

C109 DINING 9 3'-0" 6'-8" 1 3/4" TYPE C1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors

C111A BEDROOM 1 11 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

C111B BEDROOM 1 11 3'-0" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR Barn Door, Color: Contracting officer to select from manufacturer's standard colors

C113 BATH 01 13 2'-6" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

D114 GARAGE 14 3'-0" 6'-8" 1 3/4" TYPE C1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors

DOOR PANEL TYPES

DEADBOLT SPECIFICATIONS

SCHLAGE B SERIES GRADE 1 DEADBOLTS CORE LESS 1-3/4 SATIN

NICKEL US15 SCHB660J626

ZZ_SP-DOORHW_6929

HOT# 124572

CYLINDER CORE SPECIFICATIONS

SCHLAGE ZZ_SP-DOORHW_6932 SCH23-030E626 IC CORE CYLINDER E CORE

PROVIDE 2 BLANK KEYS

HOT# 117977

ENTRY DOOR HANDLE SPECIFICATIONS

SCHLAGE ND SERIES GRADE 1 CYLINDRICAL LOCK RHOES HANDLE ND 105

PASSAGE LATCH 1-3/4 2-3/4 SATIN NICKEL SCHND10SRHO626

ZZ_SP-DOORHW_6930

HOT# 133193

NOTE: LOCKSETS WILL REQUIRE EXTERIOR DOORS TO BE CUT TO RECEIVE COMMERCIAL LOCKSET.

DOOR HARDWARE

TYPE D1 TYPE D3TYPE D2

B

C

PRELIMINARY

NOT FOR

CONSTRUCTION

Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.

YELLOWSTONE NATIONAL PARK

TITLE OF SHEET

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.DESIGNED:

JC

CADD:

BB/PS/AS

TECH. REVIEW:

LF

DATE:

A/E: FIRM

PRIME:

STANTEC

CHEYENNE, WY

SHEET

OF

P

LO

T D

A

TE

R

E V

IT

V

E R

SI

O

N

198433

:3

:4

P M

A u to d e sk

D o c s:

/1

Y

E L L N

P S a rc h b d r_ a d a .r v t

3BR ABA DOOR TYPES /

SCHEDULES / DETAILS

326141A005D

06/12/2026

DOOR SCHEDULE

NO. ROOM NAME

ROOM

NO.

DOOR FRAME

DOOR COMMENTSWIDTH HEIGHT THICK TYPE MAT'L FIN GLAZ MAT'L FINISH

LEVEL 01

D101A FOYER 1 3'-0" 6'-8" 1 3/4" TYPE D1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors

D101B FOYER 1 3'-0" 6'-8" 1 3/8" TYPE D2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

D103 HALL 3 4'-0" 6'-8" 1 3/8" TYPE D3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

D104A BEDROOM 02 4 2'-8" 6'-8" 1 3/8" TYPE D2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

D104B BEDROOM 02 4 4'-0" 6'-8" 1 3/8" TYPE C3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

D106A LAUNDRY 6 3'-0" 6'-8" 1 3/4" TYPE D1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; 60 Min FRR. Solid core door. Code-compliant hardware, including gasketing, spring hinge / self-closing, must meet ABA requirements for clear opening width, maneuvering clearances, opening force; Color: Contracting officer to select from manufacturer's standard colors, Spring Hinge, Seals

D106B LAUNDRY 6 2'-8" 6'-8" 1 3/8" TYPE D2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

D107A BEDROOM 03 7 2'-8" 6'-8" 1 3/8" TYPE D2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

D107B BEDROOM 03 7 4'-0" 6'-8" 1 3/8" TYPE C3 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

D108 BATH 2 8 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: Contracting officer to select from manufacturer's standard colors

D109 DINING 9 3'-0" 6'-8" 1 3/4" TYPE D1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors

D111A BEDROOM 01 11 2'-8" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR See section 081416 for Flush Wood Doors, Craftsman Style, Color: As selected by contracting officer from manufacturer's full range of colors

D111B BEDROOM 01 11 3'-0" 6'-8" 1 3/8" TYPE D2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR Barn Door, Color: Contracting officer to select from manufacturer's standard colors

D113 BATH 01 13 3'-0" 6'-8" 1 3/8" TYPE C2 - PRE-HUNG WD STAIN/CLR N/A WD STAIN/CLR Pocket Door, Color: Contracting officer to select from manufacturer's standard colors

D114 GARAGE 14 3'-0" 6'-8" 1 3/4" TYPE D1 - PRE-HUNG GFRP SEE COMMENTS 6x, Lite Clear Low-E BY MFR COLOR See Section 081613 For Fiberglass Doors, Craftsman Style; Provide addtional rainscreen door on exterior side of opening; Contracting officer to select from manufacturer's standard colors

DOOR PANEL TYPES

DEADBOLT SPECIFICATIONS

SCHLAGE B SERIES GRADE 1 DEADBOLTS CORE LESS 1-3/4 SATIN

NICKEL US15 SCHB660J626

ZZ_SP-DOORHW_6929

HOT# 124572

CYLINDER CORE SPECIFICATIONS

SCHLAGE ZZ_SP-DOORHW_6932 SCH23-030E626 IC CORE CYLINDER E CORE

PROVIDE 2 BLANK KEYS

HOT# 117977

ENTRY DOOR HANDLE SPECIFICATIONS

SCHLAGE ND SERIES GRADE 1 CYLINDRICAL LOCK RHOES HANDLE ND 105

PASSAGE LATCH 1-3/4 2-3/4 SATIN NICKEL SCHND10SRHO626

ZZ_SP-DOORHW_6930

HOT# 133193

NOTE: LOCKSETS WILL REQUIRE EXTERIOR DOORS TO BE CUT TO RECEIVE COMMERCIAL LOCKSET.

DOOR HARDWARE

PRE-FINISHED WINDOW TRIM

WINDOW

PRE-FINISHED WINDOW TRIM

WINDOW

PRE-FINISHED WINDOW TRIM

WINDOW

A

B

C

PRELIMINARY

NOT FOR

CONSTRUCTION

Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.

YELLOWSTONE NATIONAL PARK

TITLE OF SHEET

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.DESIGNED:

JC

CADD:

BB/PS/AS

TECH. REVIEW:

LF

DATE:

A/E: FIRM

PRIME:

STANTEC

CHEYENNE, WY

SHEET

OF

P

LO

T D

A

TE

R

E V

IT

V

E R

SI

O

N

198433

:2

:3

P M

A u to d e sk

D o c s:

Y

E L L N

P S /0 a rc h b d r.

rv t

3BR WINDOW TYPES /

SCHEDULES / DETAILS

326141A006C

06/12/2026

WINDOW SCHEDULE

TYPE MARK WIDTH HEIGHT MATERIAL COMMENTS

CW1 3'-0" 5'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE

STORM SCREENS.

CW3 4'-0" 4'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE

STORM SCREENS.

CW4 3'-6" 1'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE

STORM SCREENS.

CW5 5'-0" 2'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE

STORM SCREENS.

CW1

CW2

CW3

CW4

WINDOW TYPES

* ALL BEDROOMS TO RECEIVE AW1 WINDOWS IN COMPLIANCE WITH 2024 IRC SECTION R319 MINIMUMS.

CW1

NET CLEAR WIDTH: 34" - 36"

NET CLEAR OPENING HEIGHT: 32" - 34"

NET CLEAR OPENING AREA: 8.0SF - 8.5SF

IRC MINIMUMS

NET CLEAR WIDTH: 20"

NET CLEAR HEIGHT:24"

PRE-FINISHED WINDOW TRIM

WINDOW

PRE-FINISHED WINDOW TRIM

WINDOW

PRE-FINISHED WINDOW TRIM

WINDOW

A

B

C

PRELIMINARY

NOT FOR

CONSTRUCTION

Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.

YELLOWSTONE NATIONAL PARK

TITLE OF SHEET

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.DESIGNED:

JC

CADD:

BB/PS/AS

TECH. REVIEW:

LF

DATE:

A/E: FIRM

PRIME:

STANTEC

CHEYENNE, WY

SHEET

OF

P

LO

T D

A

TE

R

E V

IT

V

E R

SI

O

N

198433

:3

:4

P M

A u to d e sk

D o c s:

/1

Y

E L L N

P S a rc h b d r_ a d a .r v t

3BR ABA WINDOW TYPES

/ SCHEDULES / DETAILS

326141A006D

06/12/2026

WINDOW SCHEDULE

Type Mark Width Height MATERIAL Comments DW1 3'-0" 5'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE

STORM SCREENS.

DW3 4'-0" 4'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE

STORM SCREENS.

DW4 3'-6" 1'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE

STORM SCREENS.

DW5 5'-0" 2'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE

STORM SCREENS.

DW1

DW2

DW3

DW4

WINDOW TYPES

* ALL BEDROOMS TO RECEIVE AW1 WINDOWS IN COMPLIANCE WITH 2024 IRC SECTION R319 MINIMUMS.

DW1

NET CLEAR WIDTH: 34" - 36"

NET CLEAR OPENING HEIGHT: 32" - 34"

NET CLEAR OPENING AREA: 8.0SF - 8.5SF

IRC MINIMUMS

NET CLEAR WIDTH: 20"

NET CLEAR HEIGHT:24"

R a n g e

WH

FD

R e fr ig e ra to r

DW

SD

SD

SD/CO

SD

A610A

A6

A610A

A9

A610A A4

A8

A610AA2

A1

B1

A200A

A

A A

A1

A200A

B

A A

A610A A3

A610A

A7

BEDROOM 02

A106A

AW2 AW2

AW1

AW1

AW1

AW1

AW1AW1

AW1

AW1

GREAT ROOM

KITCHEN

BATH 02

HALL

LAUNDRY/UTILITY

BEDROOM 01

BATH 01

MUD ROOM

A106C

A107

A101

A

A

A

A105A

A105B

A106B

LVP-1

LVP-1

TL-1

LVP-1

LVP-1

LVP-1

LVP-1

LVP-1

CPT-1

CPT-1

A

C

B

1 2 3

48'-0"

40'-0" 8'-0"

'-0

'-0

'-0

'-0

7'-8 1/2"

3'-8 1/2"

3'-0"

6'-7"

'-6

'-8

6" 12'-0" 5'-4 1/2" 8" 8 1/2"

4'-10" 6'-0 1/2" 4'-0" 5'-4 1/2" 6"

'-3

/2

'-3

'-6

'-9

/2

'-8

/2

'-6

'-1

/2

8'-0"40'-0"

48'-0"

'-0

BENCH &

COAT RACK

INCLUDE BLOCKING

FOR TV MOUNT

ABOVE RECEPTACLE

BRACED WALL

BEHIND WALL FINISH

2X6 WALL FOR DRYER VENT

TO CLEAR TRUSS

BRACED WALL

BEHIND WALL FINISH

WOOD STOVE W/

48"X48" HEARTH PAD

1'-0"

1'-4" MIN CLR

1'-11" MIN CLR

DISHWASHER

EXTERIOR VENT

RANGE HOOD W/ MICROWAVE

PANTRY

CABINET

LINEN

CABINET

4" RADON PIPE

LINEN CABINET

WASHER

& DRYER

5X SHELVES

6X6 POST

8X8

POST

8X8

POST

8X8

POST

8X8

POST

8X8

POST

6X6 POST

CRAWL

SPACE

ACCESS

'-6

/8

'-1

/2

'-2

/2

'-6

'-1

/2

'-5

'-4

/2

'-4

/2

10'-8"

2'-8"

'-2

6" 12'-0" 5'-9 1/2" 5'-3" 6'-6 1/2" 9'-5" 6"

/2

/2

A5

A10

PROVIDE STAIRS AS

REQUIRED BY SITE SPECIFIC

GRADING; RE CIVIL

ELEV=100'-0"

ELEV=100'-0"

ELEV=100'-0"

ELEV=100'-0"

A

C

B

1 2 3

2'-1 1/2"

2'-0"1'-10"

3'-9"

'-0

'-5

'-1

10'-7"

4'-10"

CENTER

CENTER

E Q

E Q

CENTER CENTER

CENTER

CENTER

WALL MOUNTED

LINEAR LED LIGHT

FAN WITH INTEGRATED

LED LIGHT

FAN WITH INTEGRATED

LED LIGHT

2'-2"

'-8

CENTER LIGHT

ABOVE SINK

'-0

'-3

/2

CEILING

ACCESS

PANEL

FIRE SUPPRESSION SYSTEM TO BE PROVIDED.

DELEGATED DESIGN. PROVIDE UPONOR AQUASAFE

SYSTEM OR APPROVED EQUAL. PROVIDE FIRE

SUPPRESSION SYSTEM DRAWINGS, HYDRAULIC

CALCULATIONS, AND MANUFACTURER'S PRODUCT

DATA SHEETS FOR REVIEW AND APPROVAL BY THE

NPS FIRE CODE OFFICIAL/AHJ OR DESIGNEE, PRIOR

TO INSTALLATION.

A

B

C

PRELIMINARY

NOT FOR

CONSTRUCTION

Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.

YELLOWSTONE NATIONAL PARK

TITLE OF SHEET

PMIS/PKG NO.

DRAWING NO.SUB SHEET NO.DESIGNED:

JC

CADD:

BB/PS/AS

TECH. REVIEW:

LF

DATE:

A/E: FIRM

PRIME:

STANTEC

CHEYENNE, WY

SHEET

OF

P

LO

T D

A

TE

R

E V

IT

V

E R

SI

O

N

198433

:4

:0

P M

A u to d e sk

D o c s:

Y

E L L N

P S /0 a rc h b d r.

rv t

2BR FLOOR & REFLECTED

CEILING PLAN

326141A101A

06/12/2026

1/4" = 1'-0"A101A

A1 FLOOR PLAN

1/4" = 1'-0"A101A

C1 REFLECTED CEILING PLAN

NOTES PLAN

1 REFERENCE ALL GENERAL NOTES ON SHEET A001

2 NIGHT SKY: PROJECT SHALL COMPLY WITH NPS AND PARK LIGHTING GUIDLINES TO REDUCE IMPACTS TO THE

NIGHT SKY AND WILDLIFE. THIS WILL INCLUDE, BUT IS NOT LIMITED TO,…