B09-Attachment_2_-_Revised_Final_Construction_Drawings_2026_08_18_Part4_0002.pdf
PDF 18 MB Posted
- Attached to
- YELL 326141 YELLOWSTONE MODULAR HOUSING
- Solicitation number
- 140P2026R0078
About this file
This document is a preliminary architectural drawing set for residential modular buildings at Yellowstone National Park, consisting of design plans and specifications for 2-bedroom and 3-bedroom units with standard and ADA-accessible variants.
The project includes four primary building configurations: a 2-bedroom standard unit, a 2-bedroom ABA (Americans with Disabilities Act) accessible unit, a 3-bedroom standard unit, and a 3-bedroom ABA accessible unit. Key building specifications include fiberglass windows with specifications referenced to 08 54 13 and 06 20 23, metal standing seam roof panels, and cement fiber siding. Windows are specified as DW1 through DW5 types with dimensions ranging from 3'-0" to 5'-0" wide and 1'-6" to 5'-6" tall. All bedroom windows must comply with 2024 IRC Section R319 minimum egress requirements. Interior finishes include gypsum board ceilings at 8-9 feet elevation with Level 5 finishes and P-1 flat sheen paint. ABA units feature accessible kitchens with removable cabinet faces, accessible bathrooms with grab bars and reinforced blocking, accessible showers with controls, ABA-compliant ranges and dishwashers, and ramp designs conforming to ABA and IBC 2021 standards with slope, width, landing, handrail, and surface requirements. The drawings indicate fire suppression systems are delegated design items requiring UPONOR AQUASAFE systems or approved equivalents with manufacturer product data sheets and hydraulic calculations submitted for NPS Fire Code Official approval. Night sky compliance is required per NPS lighting guidelines using low-level, downward-focused fixtures and low-pressure sodium lamps. Drawing sheets are marked preliminary and not for construction, dated 06/18/2026, with PMIS/PKG No. 198433 and designed by Stantec Cheyenne, WY.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRE-FINISHED WINDOW TRIM
WINDOW
PRE-FINISHED WINDOW TRIM
WINDOW
PRE-FINISHED WINDOW TRIM
WINDOW
PRE-FINISHED WINDOW TRIM
WINDOW
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:3
:4
P M
A u to d e sk
D o c s:
/1
Y
E L L N
P S a rc h b d r_ a d a .r v t
3BR ABA WINDOW TYPES
/ SCHEDULES / DETAILS
326141A006D
06/12/2026
WINDOW SCHEDULE
Type Mark Width Height MATERIAL Comments DW1 3'-0" 5'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
DW3 4'-0" 4'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
DW4 3'-6" 1'-6" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
DW5 5'-0" 2'-0" FIBERGLASS REFERENCE SPECIFICATION 08 54 13 FIBERGLASS WINDOWS & 06 20 23 INTERIOR FINISH CARPENTRY; ALL WINDOWS TO RECEIVE
STORM SCREENS.
DW1
DW2
DW3
DW4
WINDOW TYPES
* ALL BEDROOMS TO RECEIVE AW1 WINDOWS IN COMPLIANCE WITH 2024 IRC SECTION R319 MINIMUMS.
DW1
NET CLEAR WIDTH: 34" - 36"
NET CLEAR OPENING HEIGHT: 32" - 34"
NET CLEAR OPENING AREA: 8.0SF - 8.5SF
IRC MINIMUMS
NET CLEAR WIDTH: 20"
NET CLEAR HEIGHT:24"
NET CLEAR OPENING AREA: 5.7SF
06/18/2026
R a n g e
WH
FD
R e fr ig e ra to r
DW
SD
SD
SD/CO
SD
A610A
A6
A610A
A9
A610A A4
A8
A610AA2
A1
B1
A200A
A
A A
A1
A200A
B
A A
A610A A3
A610A
A7
BEDROOM 02
A106A
AW2 AW2
AW1
AW1
AW1
AW1
AW1AW1
AW1
AW1
GREAT ROOM
KITCHEN
BATH 02
HALL
LAUNDRY/UTILITY
BEDROOM 01
BATH 01
MUD ROOM
A106C
A107
A101
A
A
A
A105A
A105B
A106B
LVP-1
LVP-1
TL-1
LVP-1
LVP-1
LVP-1
LVP-1
LVP-1
CPT-1
CPT-1
A
C
B
1 2 3
48'-0"
40'-0" 8'-0"
'-0
'-0
'-0
'-0
7'-8 1/2"
3'-8 1/2"
3'-0"
6'-7"
'-6
'-8
6" 12'-0" 5'-4 1/2" 8" 8 1/2"
4'-10" 6'-0 1/2" 4'-0" 5'-4 1/2" 6"
'-3
/2
'-3
'-6
'-9
/2
'-8
/2
'-6
'-1
/2
8'-0"40'-0"
48'-0"
'-0
BENCH &
COAT RACK
INCLUDE BLOCKING
FOR TV MOUNT
ABOVE RECEPTACLE
BRACED WALL
BEHIND WALL FINISH
2X6 WALL FOR DRYER VENT
TO CLEAR TRUSS
BRACED WALL
BEHIND WALL FINISH
WOOD STOVE W/
48"X48" HEARTH PAD
1'-0"
1'-4" MIN CLR
1'-11" MIN CLR
DISHWASHER
EXTERIOR VENT
RANGE HOOD W/ MICROWAVE
PANTRY
CABINET
LINEN
CABINET
4" RADON PIPE
LINEN CABINET
WASHER
& DRYER
5X SHELVES
6X6 POST
8X8
POST
8X8
POST
8X8
POST
8X8
POST
8X8
POST
6X6 POST
CRAWL
SPACE
ACCESS
'-6
/8
'-1
/2
'-2
/2
'-6
'-1
/2
'-5
'-4
/2
'-4
/2
10'-8"
2'-8"
'-2
6" 12'-0" 5'-9 1/2" 5'-3" 6'-6 1/2" 9'-5" 6"
/2
/2
A5
A10
PROVIDE STAIRS AS
REQUIRED BY SITE SPECIFIC
GRADING; RE CIVIL
ELEV=100'-0"
ELEV=100'-0"
ELEV=100'-0"
ELEV=100'-0"
A
C
B
1 2 3
2'-1 1/2"
2'-0"1'-10"
3'-9"
'-0
'-5
'-1
10'-7"
4'-10"
CENTER
CENTER
E Q
E Q
CENTER CENTER
CENTER
CENTER
WALL MOUNTED
LINEAR LED LIGHT
FAN WITH INTEGRATED
LED LIGHT
FAN WITH INTEGRATED
LED LIGHT
2'-2"
'-8
CENTER LIGHT
ABOVE SINK
'-0
'-3
/2
CEILING
ACCESS
PANEL
FIRE SUPPRESSION SYSTEM TO BE PROVIDED.
DELEGATED DESIGN. PROVIDE UPONOR AQUASAFE
SYSTEM OR APPROVED EQUAL. PROVIDE FIRE
SUPPRESSION SYSTEM DRAWINGS, HYDRAULIC
CALCULATIONS, AND MANUFACTURER'S PRODUCT
DATA SHEETS FOR REVIEW AND APPROVAL BY THE
NPS FIRE CODE OFFICIAL/AHJ OR DESIGNEE, PRIOR
TO INSTALLATION.
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:4
:0
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
2BR FLOOR & REFLECTED
CEILING PLAN
326141A101A
06/12/2026
1/4" = 1'-0"A101A
A1 FLOOR PLAN
1/4" = 1'-0"A101A
C1 REFLECTED CEILING PLAN
NOTES PLAN
1 REFERENCE ALL GENERAL NOTES ON SHEET A001
2 NIGHT SKY: PROJECT SHALL COMPLY WITH NPS AND PARK LIGHTING GUIDLINES TO REDUCE IMPACTS TO THE
NIGHT SKY AND WILDLIFE. THIS WILL INCLUDE, BUT IS NOT LIMITED TO, LOW-LEVEL LIGHTING, MINIMIZED
GLARE, DOWNWARD FOCUSED LIGHT FIXTURES, AND ENERGY EFFICIENT LIGHT SOURCES SUCH AS
LOW-PRESSURE SODIUM LAMPS.
3 REFERENCE ALL FIRE-SUPPRESSION SPRINKLER SYSTEM REQUIREMENTS ON SHEET A001. FIRE PROTECTION
CONTRACTOR TO PROVIDE SPRINKLER SHOP DRAWINGS FOR ARCHITECT'S REVIEW AND APPROVAL.
4 REFER TO ELECTRICAL DRAWINGS FOR LIGHT SWITCH LOCATIONS.
5 ALL DIFFUSERS / GRILLS IN GYP. CEILING TO BE PAINTED TO MATCH ADJACENT FINISH. ALL COVE HEATERS
TO MATCH CEILING FINISH.
6 ALL CEILING HEIGHTS TO BE 8' U.N.O
7 ALL GYP. BD. CEILINGS SHALL BE FINISHED TO LEVEL 5 FINISH AND PAINTED P-1 FLAT SHEEN, U.N.O.
8 LIGHT/FAN COMBO TO BE SATIN NICKEL U.N.O.
9 ALL CABINETS LOCATED IN THE KITCHEN TO RECIEVE UNDER-CABINET LIGHTING.
10 MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS TO BE ENGINEERED BY RESIDENTIAL MODULAR
BUILDING MANUFACTURER. ALL ENGINEERING SHOWN IS SCHEMATIC AND FOR REFERENCE ONLY. ALL
SYSTEMS MUST MEET MANUFACTURER RECOMMENDATIONS, ALL APPLICABLE CODES AND AHJ
REQUIREMENTS.
LIGHT FIXTURE SCHEDULE
FIXTURE COUNT
LED WALL MOUNTED LIGHT FIXTURE 2
LED WALL MOUNTED SCONCE 4
UNDER CABINET LIGHTING 5
CEILING FAN WITH LED LIGHT FIXTURE 3
BATH FAN WITH LED LIGHT FIXTURE 2
RECESSED CANNED LIGHTING 10
EXTERIOR DOWNLIGHT; COMPLY WITH EXTERIOR LIGHT REGULATIONS 2
n g e
M ic ro w a v e
WH
FD
R e fr ig e ra to r
DW
SD
SD
SD/CO
A610B
B7
A610B B4
B6
A610BB2
B1
B1
A200B
A
A B
A1
A200B
B
A B
A610B B3
B5
BATH 01
MUD ROOM
BATH 02 ABA
KITCHEN
GREAT ROOM
HALL
BEDROOM 01
BEDROOM 02
CPT-1
CPT-1
LVP-1
LVP-1
LVP-1
LVP-1
LVP-1
B
LVP-1
B101
B
B
B105A
B105B
B106A
B106B
B106C
B106D
BW1
BW1
BW1 BW1
BW1
BW1
BW1
BW1
BW2BW2
A
B
C
1 2 3
40'-0" 8'-0"
'-0
'-0
'-0
8'-1 1/2"
'-0
3'-4 1/2"
5'-0"
3'-1 1/4"
'-2
'-6
'-2
'-5
/2
'-4
/2
'-4
'-0
FILLER PANEL
1/4" FILLER NEEDED BETWEEN
FRIDGE PANEL AND WALL CABINET
1/4" FILLER NEEDED BETWEEN
FRIDGE PANEL AND WALL CABINET
BENCH &
COAT RACK
INCLUDE BLOCKING FOR
TV MOUNT ABOVE
RECEPTICAL
BRACED WALL
BEHIND WALL FINISH
CRAWL
SPACE
ACCESS
ABA SINK
ABA SHOWER
4" RADON PIPE
ATTIC
ACCESS
DRYER WASHER
ABA RANGE
ABA DISHWASHERABA COUNTERTOP
MICROWAVE
EXTERIOR RANGE VENT
BRACED WALL BEHIND
WALL FINISH
PANTRY
CABINET
10 1/2"
8X8
POST
6X6 POST
8X8
POST
8X8
POST
8X8
POST
8X8
POST6X6 POST
'-2
2'-8"
6" 12'-0" 5'-4 1/2" 8"
8 1/2"
10'-10 1/2" 4'-0" 5'-4 1/2" 6" 8'-0"
'-3
/2
'-3
'-6
'-9
/2
'-8
/2
'-6
'-1
/2
6" 12'-0" 5'-9 1/2" 5'-11" 6'-3 3/4"
WOOD STOVE W/
48"X48" HEARTH PAD
1'-4" MIN CLR
1'-11" MIN CLR
/2
/2
B8
ELEV=100'-0"
RAMP DESIGN TO CONFORM TO ABA
STANDARDS FOR ACCESSIBLE DESIGN,
INCLUDING SLOPE, WIDTH, LANDINGS,
HANDRAILS, AND SURFACE REQUIREMENTS
RAMP DESIGN TO CONFORM
TO ABA STANDARDS FOR
ACCESSIBLE DESIGN,
INCLUDING SLOPE, WIDTH,
LANDINGS, HANDRAILS, AND
SURFACE REQUIREMENTS
A
B
C
1 2 3
'-0
1'-9"
CENTER
CENTER
E Q
E Q 2'-11 1/2"
CENTERCENTER
CENTER
4'-10"
10'-7" '-1
'-5
CENTER
WALL MOUNTED
LINEAR LED LIGHT
FAN WITH INTEGRATED
LED LIGHT
FAN WITH INTEGRATED
LED LIGHT
2'-2"
'-8
CENTER LIGHT
ABOVE SINK
'-3
CEILING
ACCESS
PANEL
FIRE SUPPRESSION SYSTEM TO BE PROVIDED.
DELEGATED DESIGN. PROVIDE UPONOR AQUASAFE
SYSTEM OR APPROVED EQUAL. PROVIDE FIRE
SUPPRESSION SYSTEM DRAWINGS, HYDRAULIC
CALCULATIONS, AND MANUFACTURER'S PRODUCT
DATA SHEETS FOR REVIEW AND APPROVAL BY THE
NPS FIRE CODE OFFICIAL/AHJ OR DESIGNEE, PRIOR
TO INSTALLATION.
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:0
:1
P M
A u to d e sk
D o c s:
/1
Y
E L L N
P S a rc h b d r_ a d a .r v t
2BR ABA FLOOR &
REFLECTED CEILING
PLAN
326141A/326104A101B
05/28/25
1/4" = 1'-0"A101B
A1 ABA FLOOR PLAN
1/4" = 1'-0"A101B
C1 REFLECTED CEILING PLAN
NOTES PLAN
1 REFERENCE ALL GENERAL NOTES ON SHEET A001
2 NIGHT SKY: PROJECT SHALL COMPLY WITH NPS AND PARK LIGHTING GUIDLINES TO REDUCE IMPACTS TO THE
NIGHT SKY AND WILDLIFE. THIS WILL INCLUDE, BUT IS NOT LIMITED TO, LOW-LEVEL LIGHTING, MINIMIZED
GLARE, DOWNWARD FOCUSED LIGHT FIXTURES, AND ENERGY EFFICIENT LIGHT SOURCES SUCH AS
LOW-PRESSURE SODIUM LAMPS.
3 REFERENCE ALL FIRE-SUPPRESSION SPRINKLER SYSTEM REQUIREMENTS ON SHEET A001. FIRE PROTECTION
CONTRACTOR TO PROVIDE SPRINKLER SHOP DRAWINGS FOR ARCHITECT'S REVIEW AND APPROVAL.
4 REFER TO ELECTRICAL DRAWINGS FOR LIGHT SWITCH LOCATIONS.
5 ALL DIFFUSERS / GRILLS IN GYP. CEILING TO BE PAINTED TO MATCH ADJACENT FINISH. ALL COVE HEATERS
TO MATCH CEILING FINISH.
6 ALL CEILING HEIGHTS TO BE 8' U.N.O
7 ALL GYP. BD. CEILINGS SHALL BE FINISHED TO LEVEL 5 FINISH AND PAINTED P-1 FLAT SHEEN, U.N.O.
8 LIGHT/FAN COMBO TO BE SATIN NICKEL U.N.O.
9 ALL CABINETS LOCATED IN THE KITCHEN TO RECIEVE UNDER COUNTER LIGHTING.
10 MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS TO BE ENGINEERED BY RESIDENTIAL MODULAR
BUILDING MANUFACTURER. ALL ENGINEERING SHOWN IS SCHEMATIC AND FOR REFERENCE ONLY. ALL
SYSTEMS MUST MEET MANUFACTURER RECOMMENDATIONS, ALL APPLICABLE CODES AND AHJ
REQUIREMENTS.
LIGHT FIXTURE SCHEDULE
FIXTURE COUNT
LED WALL MOUNTED LIGHT FIXTURE 2
LED WALL MOUNTED SCONCE 2
UNDER CABINET LIGHTING 5
CEILING FAN WITH LED LIGHT FIXTURE 3
BATH FAN WITH LED LIGHT FIXTURE 2
RECESSED CANNED LIGHTING 9
EXTERIOR DOWNLIGHT; COMPY WITH EXTERIOR LIGHT REGULATIONS 2
06/12/202606/18/2026 n g e
R e fr ig e ra to r
WH
FD
D W
UP
B1 A200C
A
A
0C
A1 A200C
B
A
0C
A610C B2
A610C C3 A610C C1C2
A610C A1
BEDROOM 03
BATH 02
CW1 CW4 CW4 CW3
CW5
CW1CW1
CW1
C
4A
C
C
1B C
1A
C113
C
C107B
C106A
C111B
C
7A
C
BEDROOM 02
WIC 01
DINING
KITCHEN
HALL
LAUNDRY
FOYER
LIVING ROOM
6"
2' -1
4'-6"
9' -2
3'-10"
CPT-1
CPT-1
LVP-1
LVP-1
LVP-1
LVP-1
LVP-1
LVP-1
LVP-1
CPT-1
LVP-1
BATH 01
LVP-1
A
B
C
2 3
A610C
B3
20'-0" 56'-0"
4" RADON
REVENT
STACKED
W/D
'-0
'-0
'-0
EXTERIOR VENT
RANGE HOOD W/
MICROWAVE
SHORT
PLUMBING WALL
CRAWL
SPACE
ACCESS
76'-0"
6" 9'-9" 9'-8 7/8" 5'-3" 9'-0 5/8" 2'-5" 9'-0 5/8" 6'-9 1/4" 5'-0 1/4" 4'-7" 8'-11 3/4" 4'-4 3/4" 6"
CW1
6" 6'
-6
6' -8
'-1 0"
6"
2'-4" 7'-11" 7'-11" 2'-3 7/8" 6'-0 1/2" 3'-5 1/2" 3'-5 1/2" 5'-2 1/4" 11'-3 3/16" 6'-0" 6'-7 11/16" 3'-5 1/2" 3'-5 1/2" 6'-0 1/2"
CW1
INCLUDE BLOCKING FOR
TV MOUNT ABOVE
RECEPTICAL
INCLUDE BLOCKING FOR
TV MOUNT ABOVE
RECEPTICAL
BRACED WALL
BEHIND WALL FINISH
DISHWASHER
PANTRY
CABINET
BRACED WALL BEHIND
WALL FINISH
ELEV=100'-0"
ELEV=100'-0"
ELEV=100'-0"
ELEV=100'-0"
FIRE PROTECTION
BETWEEN GARAGE
AND LIVING UNIT
GARAGE DOOR 16' x 8'
A610C B1
S
H E
LF
/R
O D
2'-0"
2' -8
S
H E
LF
/R
O D
(5) SHELVES
1 SHELF/ROD
BEDROOM 1
INCLUDE BLOCKING FOR
TV MOUNT ABOVE
RECEPTICAL
INCLUDE BLOCKING FOR
TV MOUNT ABOVE
RECEPTICAL
INCLUDE BLOCKING FOR
TV MOUNT ABOVE
RECEPTICAL
CW1
1 SHELF/ROD
1 SHELF/ROD
S
H E
LF
/R
O D
S
H E
LF
/R
O D
C
LO
S E
T
T O
W E
R
TL-1
WOOD STOVE W/
48"X48" HEARTH PAD
1'-4" MIN CLR
RE: STRUC. GRINDER SUMP
PUMP FLUSH WITH FLOOR;
PROVIDED REMOVABLE
DIAMOND PLATED STAINLESS
STEEL PROTECTION
MECH/STORAGE
C104B
C
6B
GARAGE
D114
C111A
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:2
:3
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
3BR FLOOR PLAN
326141A101C
06/12/2026
1/4" = 1'-0"A101C
A1 FLOOR PLAN
NOTES PLAN
1 REFERENCE ALL GENERAL NOTES ON SHEET A001
2 NIGHT SKY: PROJECT SHALL COMPLY WITH NPS AND PARK LIGHTING GUIDLINES TO REDUCE IMPACTS TO THE NIGHT SKY AND WILDLIFE. THIS WILL INCLUDE, BUT IS NOT LIMITED TO, LOW-LEVEL LIGHTING, MINIMIZED GLARE, DOWNWARD FOCUSED LIGHT FIXTURES, AND ENERGY EFFICIENT LIGHT SOURCES SUCH AS
LOW-PRESSURE SODIUM LAMPS.
3 REFERENCE ALL FIRE-SUPPRESSION SPRINKLER SYSTEM REQUIREMENTS ON SHEET A001. FIRE PROTECTION CONTRACTOR TO PROVIDE SPRINKLER SHOP DRAWINGS FOR ARCHITECT'S REVIEW AND APPROVAL.
4 REFER TO ELECTRICAL DRAWINGS FOR LIGHT SWITCH LOCATIONS.
5 MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS TO BE ENGINEERED BY RESIDENTIAL MODULAR BUILDING MANUFACTURER; ALL COVE HEATERS TO MATCH CEILING FINISH. ALL ENGINEERING SHOWN IS SCHEMATIC AND FOR REFERENCE ONLY. ALL SYSTEMS MUST MEET MANUFACTURER RECOMMENDATIONS
AND ALL APPLICABLE CODES AND AHJ REQUIREMENTS.
6 ALL CEILING HEIGHTS TO BE 8' U.N.O.
7 ALL GYP. BD. CEILINGS SHALL BE FINISHED TO LEVEL 5 FINISH AND PAINTED P-1 FLAT SHEEN, U.N.O.
8 LIGHT/FAN COMBO TO BE SATIN NICKEL U.N.O.
9 ALL CABINETS LOCATED IN THE KITCHEN TO RECEIVE UNDER COUNTER LIGHTING.
n g e
R e fr ig e ra to r
D W
M ic ro w a v e
WH
FD
B1 A200D
A
A
0D
A1 A200D
B
A
0D
A610D B2
A610D C3 A610D C1C2 A610D A1
BEDROOM 03
BEDROOM 01
DW1 DW4 DW4 DW3
DW5
DW1DW1
D
4A
D
D
1B D
1A
D
D106A
D
7A
BEDROOM 02
WIC 01
DINING
KITCHEN
HALL
LAUNDRY
FOYER
LIVING ROOM
2' -0
/2
4'-6"
9' -2
CPT-1
CPT-1
LVP-1
LVP-1
LVP-1
LVP-1
LVP-1
LVP-1
CPT-1
LVP-1
BATH 01
LVP-1
A
B
C
2 3
A610D
B3
'-0
RADON
VENT
'-0
'-0
6" 9'-9" 9'-8 7/8" 5'-3" 20'-6 1/8" 6'-9 1/4" 5'-0 1/4" 4'-7" 9'-8 1/2" 3'-8" 6"
20'-0" 56'-0"
76'-0"
DW1DW1
6" 6'
-6
6' -8
'-1 0"
6"
2'-4" 7'-11" 7'-11" 2'-3 7/8" 6'-0 1/2" 3'-5 1/2" 3'-5 1/2" 5'-2 1/4" 4'-7 1/2" 6'-7 3/4" 6'-0" 6'-7 3/4" 3'-5 1/2" 3'-5 1/2" 6'-0 1/2"
DW1
D R
Y E
R W
A S
H E
R
MIN CLR
6'-4 7/64"
D111B
BRACED WALL
BEHIND WALL FINISH
ABA RANGE
ABA DISHWASHER
ABA COUNTERTOP
MICROWAVE
PANTRY
CABINET
BRACED WALL BEHIND
WALL FINISH
ELEV=100'-0"
ELEV=100'-0"
REINFORCEMENT TO PERMIT
THE INSTALLATION OF GRAB
BARS
GARAGE DOOR 16' x 8'
FIRE PROTECTION
BETWEEN GARAGE
AND LIVING UNIT
RAMP DESIGN TO CONFORM TO ABA & IBC 2021
STANDARDS FOR ACCESSIBLE DESIGN,
INCLUDING SLOPE, WIDTH, LANDINGS,
HANDRAILS, AND SURFACE REQUIREMENTS
RAMP DESIGN TO CONFORM TO ABA & IBC 2021
STANDARDS FOR ACCESSIBLE DESIGN,
INCLUDING SLOPE, WIDTH, LANDINGS,
HANDRAILS, AND SURFACE REQUIREMENTS
RAMP DESIGN TO CONFORM TO ABA & IBC 2021
STANDARDS FOR ACCESSIBLE DESIGN,
INCLUDING SLOPE, WIDTH, LANDINGS,
HANDRAILS, AND SURFACE REQUIREMENTS
RE: STRUC. GRINDER SUMP
PUMP FLUSH WITH FLOOR;
PROVIDED REMOVABLE
DIAMOND PLATED STAINLESS
STEEL PROTECTION
TL-1
WOOD STOVE W/
48"X48" HEARTH PAD
1'-4" MIN CLR
S
H E
LF
/R
O D
A610D B1
2'-2"
2' -8
S
H E
LF
/R
O D
MECH/STORAGE
BATH 2
LVP-1
DW1
1 SHELF/ROD
1 SHELF/ROD
CONTROLS
ABA SHOWER DOOR
ABA SHOWER HEAD
INCLUDE BLOCKING FOR
TV MOUNT ABOVE
RECEPTICAL
INCLUDE BLOCKING FOR
TV MOUNT ABOVE
RECEPTICAL
INCLUDE BLOCKING FOR
TV MOUNT ABOVE
RECEPTICAL
INCLUDE BLOCKING FOR
TV MOUNT ABOVE
RECEPTICAL
(5) SHELVES
1 SHELF/ROD
D104B
D
6B
D
D107B
D111A
D
D114
GARAGE
MIN
5'-7"
MAX
9"
MIN
5'-7"
M
IN
5' -0
MIN
5'-0"
MIN
5'-7"
MAX
9"
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:3
:4
P M
A u to d e sk
D o c s:
/1
Y
E L L N
P S a rc h b d r_ a d a .r v t
3BR ABA FLOOR PLAN
326141A101D
06/12/2026
1/4" = 1'-0"A101D
A1 ABA FLOOR PLAN
NOTES PLAN
1 REFERENCE ALL GENERAL NOTES ON SHEET A001
2 NIGHT SKY: PROJECT SHALL COMPLY WITH NPS AND PARK LIGHTING GUIDLINES TO REDUCE IMPACTS TO THE NIGHT SKY AND WILDLIFE. THIS WILL INCLUDE, BUT IS NOT LIMITED TO, LOW-LEVEL LIGHTING, MINIMIZED GLARE, DOWNWARD FOCUSED LIGHT FIXTURES, AND ENERGY EFFICIENT LIGHT SOURCES SUCH AS
LOW-PRESSURE SODIUM LAMPS.
3 REFERENCE ALL FIRE-SUPPRESSION SPRINKLER SYSTEM REQUIREMENTS ON SHEET A001. FIRE PROTECTION CONTRACTOR TO PROVIDE SPRINKLER SHOP DRAWINGS FOR ARCHITECT'S REVIEW AND APPROVAL.
4 REFER TO ELECTRICAL DRAWINGS FOR LIGHT SWITCH LOCATIONS.
5 ALL DIFFUSERS / GRILLS IN GYP. CEILING TO BE PAINTED TO MATCH ADJACENT FINISH. ALL COVE HEATERS
TO MATCH CEILING FINISH.
6 ALL CEILING HEIGHTS TO BE 8' U.N.O
7 ALL GYP. BD. CEILINGS SHALL BE FINISHED TO LEVEL 5 FINISH AND PAINTED P-1 FLAT SHEEN, U.N.O.
8 LIGHT/FAN COMBO TO BE SATIN NICKEL U.N.O.
9 ALL CABINETS LOCATED IN THE KITCHEN TO RECIEVE UNDER COUNTER LIGHTING.
10 MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS TO BE ENGINEERED BY RESIDENTIAL MODULAR BUILDING MANUFACTURER. ALL ENGINEERING SHOWN IS SCHEMATIC AND FOR REFERENCE ONLY. ALL
SYSTEMS MUST MEET MANUFACTURER RECOMMENDATIONS AND ALL APPLICABLE CODES AND AHJ
REQUIREMENTS.
SD
SD
SD/CO
SD
SD/CO
A
B
C
2 31
2'-0"
'-8
"CEILING
ACCESS
PANEL
GWB 8' - 0"
GWB 8' - 0"
GWB 8' - 0"
GWB 9' - 0"
GWB 9' - 0"
GWB 9' - 0"
GWB 8' - 0"
GWB 8' - 0"
GWB 8' - 8"
GWB 9' - 0"GWB 9' - 0" GWB 9' - 0"
GWB 8' - 0"
GWB 9' - 0"
GWB 8' - 0"
'-0
'-2
2'-0" 6" 3'-6" 6" 4'-3 1/8" 6" 3'-6" 6"
GWB 8' - 0"
GWB 8' - 0"
GWB 8' - 0"
GARAGE
MECH/STORAGE
BEDROOM 02
LAUNDRY
HALL
DINING KITCHENBATH 02BEDROOM 03
LIVING ROOM
BEDROOM 1
WIC 01
BATH 01
GWB 9' - 0"
FIRE SUPPRESSION SYSTEM TO BE PROVIDED.
DELEGATED DESIGN. PROVIDE UPONOR AQUASAFE
SYSTEM OR APPROVED EQUAL. PROVIDE FIRE
SUPPRESSION SYSTEM DRAWINGS, HYDRAULIC
CALCULATIONS, AND MANUFACTURER'S PRODUCT
DATA SHEETS FOR REVIEW AND APPROVAL BY THE
NPS FIRE CODE OFFICIAL/AHJ OR DESIGNEE, PRIOR
TO INSTALLATION.
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:2
:1
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
3BR REFLECTED CEILING
PLAN
326141A102C
06/12/2026
1/4" = 1'-0"A102C
A1 REFLECTED CEILING PLAN
NOTES PLAN
1 REFERENCE ALL GENERAL NOTES ON SHEET A001
2 NIGHT SKY: PROJECT SHALL COMPLY WITH NPS AND PARK LIGHTING GUIDLINES TO REDUCE IMPACTS TO THE
NIGHT SKY AND WILDLIFE. THIS WILL INCLUDE, BUT IS NOT LIMITED TO, LOW-LEVEL LIGHTING, MINIMIZED
GLARE, DOWNWARD FOCUSED LIGHT FIXTURES, AND ENERGY EFFICIENT LIGHT SOURCES SUCH AS
LOW-PRESSURE SODIUM LAMPS.
3 REFERENCE ALL FIRE-SUPPRESSION SPRINKLER SYSTEM REQUIREMENTS ON SHEET A001. FIRE PROTECTION
CONTRACTOR TO PROVIDE SPRINKLER SHOP DRAWINGS FOR ARCHITECT'S REVIEW AND APPROVAL.
4 REFER TO ELECTRICAL DRAWINGS FOR LIGHT SWITCH LOCATIONS.
5 MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS TO BE ENGINEERED BY RESIDENTIAL MODULAR
BUILDING MANUFACTURER; ALL COVE HEATERS TO MATCH CEILING FINISH. ALL ENGINEERING SHOWN IS
SCHEMATIC AND FOR REFERENCE ONLY. ALL SYSTEMS MUST MEET MANUFACTURER RECOMMENDATIONS
AND ALL APPLICABLE CODES AND AHJ REQUIREMENTS.
6 ALL CEILING HEIGHTS TO BE 8' U.N.O.
7 ALL GYP. BD. CEILINGS SHALL BE FINISHED TO LEVEL 5 FINISH AND PAINTED P-1 FLAT SHEEN, U.N.O.
8 LIGHT/FAN COMBO TO BE SATIN NICKEL U.N.O.
9 ALL CABINETS LOCATED IN THE KITCHEN TO RECEIVE UNDER COUNTER LIGHTING.
LIGHT FIXTURE SCHEDULE
FIXTURE COUNT
LED WALL MOUNTED SCONCE 2
CEILING FAN WITH LED LIGHT FIXTURE 3
BATH FAN WITH LED LIGHT FIXTURE 2
RECESSED CANNED LIGHTING 29
LED PENDANT LIGHT 3
EXTERIOR DOWNLIGHT; COMPLY WITH EXTERIOR LIGHT REGULATIONS 1
SD
SD/CO
SD
SD/CO
A
B
C
2 31
GWB 8' - 0"
GWB 8' - 0"
GWB 8' - 0"
GWB 8' - 0"
GWB 9' - 0"
GWB 9' - 0"
GWB 8' - 8"
GWB 9' - 0"GWB 9' - 0" GWB 9' - 0"
GWB 8' - 0"
GWB 9' - 0"
'-0
'-2
2'-0" 6" 3'-6" 6" 4'-3 1/8" 6" 3'-6" 6"
GWB 8' - 0"
GWB 8' - 0"
GWB 8' - 0"
CEILING
ACCESS
PANEL
GWB 8' - 0"
GWB 8' - 0"
GWB 8' - 0"
GWB 8' - 0"
GARAGE
LAUNDRY
MECH/STORAGE
BEDROOM 02
FOYER
LIVING ROOM
DINING KITCHEN
BEDROOM 03
BATH 2
WIC 01
BATH 01
BEDROOM 01
GWB 9' - 0"
FIRE SUPPRESSION SYSTEM TO BE PROVIDED.
DELEGATED DESIGN. PROVIDE UPONOR AQUASAFE
SYSTEM OR APPROVED EQUAL. PROVIDE FIRE
SUPPRESSION SYSTEM DRAWINGS, HYDRAULIC
CALCULATIONS, AND MANUFACTURER'S PRODUCT
DATA SHEETS FOR REVIEW AND APPROVAL BY THE
NPS FIRE CODE OFFICIAL/AHJ OR DESIGNEE, PRIOR
TO INSTALLATION.
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:3
:4
P M
A u to d e sk
D o c s:
/1
Y
E L L N
P S a rc h b d r_ a d a .r v t
3BR ABA REFLECTED
CEILING PLAN
326141A102D
06/12/2026
1/4" = 1'-0"A102D
A1 REFLECTED CEILING PLAN
NOTES PLAN
1 REFERENCE ALL GENERAL NOTES ON SHEET A001
2 NIGHT SKY: PROJECT SHALL COMPLY WITH NPS AND PARK LIGHTING GUIDLINES TO REDUCE IMPACTS TO THE
NIGHT SKY AND WILDLIFE. THIS WILL INCLUDE, BUT IS NOT LIMITED TO, LOW-LEVEL LIGHTING, MINIMIZED
GLARE, DOWNWARD FOCUSED LIGHT FIXTURES, AND ENERGY EFFICIENT LIGHT SOURCES SUCH AS
LOW-PRESSURE SODIUM LAMPS.
3 REFERENCE ALL FIRE-SUPPRESSION SPRINKLER SYSTEM REQUIREMENTS ON SHEET A001. FIRE PROTECTION
CONTRACTOR TO PROVIDE SPRINKLER SHOP DRAWINGS FOR ARCHITECT'S REVIEW AND APPROVAL.
4 REFER TO ELECTRICAL DRAWINGS FOR LIGHT SWITCH LOCATIONS.
5 ALL DIFFUSERS / GRILLS IN GYP. CEILING TO BE PAINTED TO MATCH ADJACENT FINISH. ALL COVE HEATERS
TO MATCH CEILING FINISH.
6 ALL CEILING HEIGHTS TO BE 8' U.N.O
7 ALL GYP. BD. CEILINGS SHALL BE FINISHED TO LEVEL 5 FINISH AND PAINTED P-1 FLAT SHEEN, U.N.O.
8 LIGHT/FAN COMBO TO BE SATIN NICKEL U.N.O.
9 ALL CABINETS LOCATED IN THE KITCHEN TO RECIEVE UNDER COUNTER LIGHTING.
10 MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS TO BE ENGINEERED BY RESIDENTIAL MODULAR
BUILDING MANUFACTURER. ALL ENGINEERING SHOWN IS SCHEMATIC AND FOR REFERENCE ONLY. ALL
SYSTEMS MUST MEET MANUFACTURER RECOMMENDATIONS AND ALL APPLICABLE CODES AND AHJ
REQUIREMENTS.
LIGHT FIXTURE SCHEDULE
FIXTURE COUNT
LED WALL MOUNTED SCONCE 2
UNDER CABINET LIGHTING 2
CEILING FAN WITH LED LIGHT FIXTURE 3
BATH FAN WITH LED LIGHT FIXTURE 2
RECESSED CANNED LIGHTING 29
LED PENDANT LIGHT 3
EXTERIOR DOWNLIGHT; COMPLY WITH EXTERIOR LIGHT REGULATIONS 1
LEVEL 01
100'-0"
LEVEL 02
108'-0"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
AC B
'-4
/4
'-0
/2
'-0
/4
METAL STANDING SEAM
ROOF PANEL
FIBERGLASS WINDOW
VENTILATION CODE
REQUIREMENT TO BE MET
EXTERIOR DOOR
HANDRAIL
STROBE
EXTERIOR ELECTRICAL OUTLET
LEVEL 01
100'-0"
LEVEL 02
108'-0"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
A CB
'-4
/4
'-0
/2
'-0
/4
METAL STANDING SEAM
ROOF PANEL
FIBERGLASS WINDOW
VENTILATION CODE
REQUIREMENT TO BE MET
ELECTRICAL PANEL
FIBERGLASS WINDOW
MODULAR BUILDINGS MANUFACTURER TO PROVIDE DECORATIVE, NON-
FUNCTIONAL SHUTTERS AT ALL WINDOWS. WOOD SHUTTERS ARE NOT
ALLOWED. ALIGN TOP OF SHUTTER WITH TOP OF WINDOW TRIM AND
BOTTOM OF SHUTTER WITH TOP OF WINDOW SILL. STYLE AND COLOR
OPTIONS SHALL BE INCLUDED IN MODULAR BUILDING SHOP DRAWINGS.
LEVEL 01
100'-0"
LEVEL 02
108'-0"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
/2
'-0
'-4
/4
'-0
/4
METAL STANDING SEAM
ROOF PANEL
EXTERIOR DOOR
HANDRAIL
FIBERGLASS WINDOW
VENTILATION CODE
REQUIREMENT TO BE MET EXTERIOR
ELECTRICAL OUTLET
HANDRAIL
EXTERIOR HOSE BIB
LEVEL 01
100'-0"
LEVEL 02
108'-0"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
1 2 3
'-4
/4
'-0
/2
'-0
/4
METAL STANDING SEAM
ROOF PANEL
HANDRAIL
FIBERGLASS WINDOW
CEMENT FIBER SIDING
FIBERGLASS WINDOW
VENTILATION CODE
REQUIREMENT TO BE MET
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:4
:1
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
2BR ELEVATIONS
326141A200A
06/12/2026
1/4" = 1'-0"A200A
A2 FRONT ELEVATION
1/4" = 1'-0"A200A
B2 REAR ELEVATION
1/4" = 1'-0"A200A
A1 RIGHT ELEVATION 2 BEDROOM
1/4" = 1'-0"A200A
B1 LEFT ELEVATION
LEVEL 02
108'-0"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
ABC
'-4
/4
'-0
/2
'-0
/4
METAL STANDING SEAM
ROOF PANEL
FIBERGLASS WINDOW
VENTILATION CODE
REQUIREMENT TO BE MET
EXTERIOR DOOR
HANDRAIL
STROBE
EXTERIOR ELECTRICAL OUTLET
LEVEL 01
100'-0"
LEVEL 02
108'-0"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
A B C
'-4
/4
'-0
/2
'-0
/4
METAL STANDING SEAM
ROOF PANEL
FIBERGLASS WINDOW
VENTILATION CODE
REQUIREMENT TO BE MET
ELECTRICAL PANEL
FIBERGLASS WINDOW
MODULAR BUILDINGS MANUFACTURER TO PROVIDE DECORATIVE, NON-
FUNCTIONAL SHUTTERS AT ALL WINDOWS. WOOD SHUTTERS ARE NOT
ALLOWED. ALIGN TOP OF SHUTTER WITH TOP OF WINDOW TRIM AND
BOTTOM OF SHUTTER WITH TOP OF WINDOW SILL. STYLE AND COLOR
OPTIONS SHALL BE INCLUDED IN MODULAR BUILDING SHOP DRAWINGS.
LEVEL 01
100'-0"
LEVEL 02
108'-0"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
/2
'-0
'-4
/4
'-0
/4
METAL STANDING SEAM
ROOF PANEL
EXTERIOR DOOR
HANDRAIL
FIBERGLASS WINDOW
VENTILATION CODE
REQUIREMENT TO BE MET EXTERIOR
ELECTRICAL OUTLET
HANDRAIL
EXTERIOR HOSE BIB
LEVEL 01
100'-0"
LEVEL 02
108'-0"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
1 2 3
'-4
/4
'-0
/2
'-0
/4
METAL STANDING SEAM
ROOF PANEL
HANDRAIL
FIBERGLASS WINDOW
CEMENT FIBER SIDING
FIBERGLASS WINDOW
VENTILATION CODE
REQUIREMENT TO BE MET
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:0
:1
P M
A u to d e sk
D o c s:
/1
Y
E L L N
P S a rc h b d r_ a d a .r v t
2BR ABA ELEVATIONS
326141A/326104A200B
05/28/25
1/4" = 1'-0"A200B
A2 FRONT ELEVATION
1/4" = 1'-0"A200B
B2 REAR ELEVATION
1/4" = 1'-0"A200B
A1 RIGHT ELEVATION
1/4" = 1'-0"A200B
LEVEL 02
108'-11 1/2"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
ABC
CEMENT FIBER SIDING
METAL STANDING SEAM
ROOF PANEL
FIBERGLASS WINDOW
LEVEL 01
100'-0"
LEVEL 02
108'-11 1/2"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
A B C
CEMENT FIBER SIDING ELECTRICAL PANEL
23 1
METAL STANDING SEAM
ROOF PANEL
METAL STANDING SEAM
ROOF PANEL
FIBERGLASS WINDOWCEMENT FIBER SIDING
FIBERGLASS WINDOW
VENTILATION CODE
REQUIREMENT TO BE MET
2 31
METAL STANDING SEAM
ROOF PANELSTROBE
CEMENT FIBER SIDING FIBERGLASS WINDOWGARAGE DOOR VENTILATION CODE
REQUIREMENT TO BE MET
MODULAR BUILDINGS MANUFACTURER TO PROVIDE DECORATIVE, NON-
FUNCTIONAL SHUTTERS AT ALL WINDOWS. WOOD SHUTTERS ARE NOT
ALLOWED. ALIGN TOP OF SHUTTER WITH TOP OF WINDOW TRIM AND
BOTTOM OF SHUTTER WITH TOP OF WINDOW SILL. STYLE AND COLOR
OPTIONS SHALL BE INCLUDED IN MODULAR BUILDING SHOP DRAWINGS.
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:2
:3
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
3BR ELEVATIONS
326141A200C
06/12/2026
1/4" = 1'-0"A200C
A2 FRONT ELEVATION
1/4" = 1'-0"A200C
B2 REAR ELEVATION
1/4" = 1'-0"A200C
A1 RIGHT ELEVATION
1/4" = 1'-0"A200C
LEVEL 02
108'-11 1/2"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
ABC
CEMENT FIBER SIDING
METAL STANDING SEAM
ROOF PANEL
FIBERGLASS WINDOWVENTILATION CODE
REQUIREMENT TO BE MET
LEVEL 01
100'-0"
LEVEL 02
108'-11 1/2"
TO FOUNDATION
99'-0 1/2"
GRADE
98'-4 1/2"
RIDGE
115'-4 3/4"
A B C
CEMENT FIBER SIDING ELECTRICAL PANEL
23 1
METAL STANDING SEAM
ROOF PANEL
ELECTRICAL OUTLET CEMENT FIBER SIDINGFIBERGLASS WINDOW VENTILATION CODE
REQUIREMENT TO BE MET
2 31
METAL STANDING SEAM
ROOF PANEL
STROBE
CEMENT FIBER SIDINGEXTERIOR DOOR
FIBERGLASS WINDOW
CEMENT FIBER SIDINGGARAGE DOOR VENTILATION CODE
REQUIREMENT TO BE MET MODULAR BUILDINGS MANUFACTURER TO PROVIDE DECORATIVE, NON-
FUNCTIONAL SHUTTERS AT ALL WINDOWS. WOOD SHUTTERS ARE NOT
ALLOWED. ALIGN TOP OF SHUTTER WITH TOP OF WINDOW TRIM AND
BOTTOM OF SHUTTER WITH TOP OF WINDOW SILL. STYLE AND COLOR
OPTIONS SHALL BE INCLUDED IN MODULAR BUILDING SHOP DRAWINGS.
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:3
:4
P M
A u to d e sk
D o c s:
/1
Y
E L L N
P S a rc h b d r_ a d a .r v t
3BR ABA ELEVATIONS
326141A200D
06/12/2026
1/4" = 1'-0"A200D
A2 FRONT ELEVATION
1/4" = 1'-0"A200D
B2 REAR ELEVATION
1/4" = 1'-0"A200D
A1 RIGHT ELEVATION
1/4" = 1'-0"A200D
1'-9"1'-9"
3'-6"
1 1/4" 1 1/4"
**TOEKICK
**CABINETS
**PULL
/8
**FLOATING SHELVES
3'-7" 3'-0"
**UPPER CABINETS
**SHELVES
**PULL
**COUNTERTOP & BACKSPLASH
**DISHWASHER
**CABINET
**TOE KICK
**BASE CABINETS
2'-0" 2'-0" 4'-0" 2'-0" 1'-0"
2'-0"
1'-0"
1'-0"1'-6"3'-0"2'-0"2'-6"3'-0"5"
3'-0"5"
**FILLER PANEL
3'-6 3/4" 2'-6" 2'-1 1/4" 2'-6"
10'-8"
**BATHTUB
**COUNTERTOP & BACKSPLASH
**CABINETS
**PULL
**MIRROR
**SHOWER HEAD
**FAUCET CONTROLS
**FAUCET
**TOWEL BAR
**ROBE HOOK
5'-0 1/8"
4 1/2"
1'-8"
**TOE KICK
**BATHTUB
**CABINETS
**PULL7
**SPOUT
**SHOWERHEAD
**FAUCET
**TOWEL BAR
1'-8" 1'-8" 1'-8" 1'-8" 1'-8" 3"
**TOEKICK
**CABINETS
**PULL
**COUNTERTOP
/2
3"
**UPPER CABINETS
**REFRIGERATOR
**MICROWAVE
**SHELVES
**COUNTERTOP & BACKSPLASH
**PULL
**LOWER CABINETS
**OVEN/RANGE
**TOE KICK
2'-0" 2'-0" 2'-6" 1'-9" 3'-3" 1'-6" 2"
1'-0" 1'-0" 2'-6" 1'-9"
1 1/2"
3'-0"
1 1/2"
1'-8" 2"
2'-6"
2'-10" 6'-0"
8'-10"
**COUNTERTOP & BACKSPLASH
**PULL
**DRAWERS
**BATHTUB
**TOILET
**CABINETS
**TOE KICK
**MIRROR
**LIGHT
**SHOWER HEAD & FAUCET
**TOWEL BAR
**ROBE HOOK
**TISSUE HOLDER
**TOILET
**DOOR
**SHOWER HEAD
**CONTROLS
**FAUCET
**TUB
5'-0"
**TOWEL BAR
**ROBE HOOK
**TOWEL BAR
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:4
:1
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
2BR INTERIOR
ELEVATIONS
326141A610A
06/12/2026
1/4" = 1'-0"A610A
A6 HALLWAY - LEFT
1/4" = 1'-0"A610A
A7 LAUNDRY/UTILITY - LEFT
1/4" = 1'-0"A610A
A1 KITCHEN - LEFT
1/4" = 1'-0"A610A
A9 BATH 02 - RIGHT
1/4" = 1'-0"A610A
A8 BATH 02 - FRONT
1/4" = 1'-0"A610A
A3 MUDROOM - FRONT
1/4" = 1'-0"A610A
A2 KITCHEN - REAR
1/4" = 1'-0"A610A
A4 BATH 01 - FRONT 2 BEDROOM
1/4" = 1'-0"A610A
A10 BATH 02 - BACK
1/4" = 1'-0"A610A
A5 BATH 01 - RIGHT
9"
**UPPER CABINETS
**FLOATING SHELVES
**PULL
**TOE KICK
**COUNTERTOP & BACKSPLASH
**BASE CABINETS
**DISHWASHER
**REFRIGERATOR
8' -0
M A
X
2' -1
0" 1'
-8
3' -4
2"
1" 2'-10" 2'-0" 2'-0" 4'-0" 2'-0" 2'-0"
1"
2'-10" 3'-0"2'-0" 1'-6"
REMOVABLE CABINET FACE
FOR ADA ACCESS @ SINK
9"1'-0"
**UNDER CABINET LIGHTING
2'-6"
11'-4"
**ABA BATHTUB/SHOWER
**GRAB BARS INSTALLED
PER ABA REQUIREMENTS;
PROVIDE BLOCKING
**COUNTERTOP & BACKSPLASH
1'
-2
5'-0"
7' -6
2' -7
**MIRROR PER ABA REQUIREMENTS
6"
** ABA SPOUT
** ABA FAUCET
** ABA SHOWERHEAD
**TOWEL BAR PER ABA REQUIREMENTS
1' -2
6'
-1 0"
1' -8
3' -1
/2
1'
-6
**DOOR
**GRAB BARS
**BATHTUB
** ABA SPOUT
** ABA FAUCET
** ABA SHOWERHEAD
5'-4" 3'-6"
8'-10"
1' -2
"2' -1
0"
4"
5' -2
**TOE KICK
**CABINETS
**PULL
**DRAWERS
**COUNTERTOP & BACKPLASH
**TOILET
**BATHTUB
1'-4 3/4"
7' -6
**MIRROR
6"
**TOWEL BAR
8'-10"
**TOE KICK
**CABINETS/DRAWERS
**PULL
**COUNTERTOP
3"
2" 1'-8" 1'-8"
M A
X
1' -7
1' -2
6'
-1 0"
**BATHTUB
**SPOUT
**FAUCET
**FAUCET
9" 2'
-1
**UPPER CABINETS
**REFRIGERATOR; PROVIDE MANUF.
RECOMMENDED CLEARANCE
**OVEN/RANGE
**LOWER CABINETS
**TOE KICK
**PULL
**COUNTERTOP & BACKSPLASH
**FLOATING SHELVING
0"
8' -0
1'-0" 1'-0" 2'-0" 2'-6" 1'-9" 3'-3" 1'-6" 2 1/2"
2'-0" 2'-6" 1'-9"
1 1/2"
3'-0"
1 1/2"
1'-6"
2 1/2"
2' -1
0" 1'
-8
3' -6
1' -8
1'
-3
2' -3
RANGE HOOD
9"
FALSE DRAWER
SWITCHES FOR RANGE HOOD & LIGHT
**FILLER PANEL
**GRAB BARS INSTALLED
PER ABA REQUIREMENTS;
PROVIDE BLOCKING
**TOILET
**DOOR
**TISSUE HOLDER
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:0
:1
P M
A u to d e sk
D o c s:
/1
Y
E L L N
P S a rc h b d r_ a d a .r v t
2BR ABA INTERIOR
ELEVATIONS
326141A/326104A610B
05/28/25
1/4" = 1'-0"A610B
B1 ABA KITCHEN - LEFT
1/4" = 1'-0"A610B
B7 ABA BATH 02 - RIGHT
1/4" = 1'-0"A610B
B6 ABA BATH 02 - FRONT
1/4" = 1'-0"A610B
B4 BATH 01 - FRONT
1/4" = 1'-0"A610B
B3 ABA MUDROOM - FRONT
1/4" = 1'-0"A610B
B5 BATH 01 - RIGHT
1/4" = 1'-0"A610B
B2 ABA KITCHEN - REAR
1/4" = 1'-0"A610B
B8 ABA BATH 02 - BACK
4'-1" 1'-4" 3'-4" 1'-4" 3'-0" 1"
**CABINETS/DRAWERS
**PULL
**COUNTERTOP & BACKSPLASH
**CABINET
**MIRROR
3'-6"
8 1/2"
4'-6"
2"
2'-3" 1 9/16"
**WASHER/DRIER
**COUNTERTOP & BACKSPLASH
**PULL
**CABINETS
**TOE KICK
**UPPER CABINETS
1'-0" 2'-0" 3'-0" 1'-6" 1'-6"
**COUNTERTOP
**DRAWER
**PULL
**TOE KICK
**CABINETS
**DISHWASHER
OPEN TO
BEYOND
3'-0" 3'-0" 3'-0"
**COUNTERTOP
**PULL
**CABINETS
**TOE KICK
OPEN TO
BEYOND
2'-7" 2'-6" 2'-6" 5'-7"
**UPPER CABINETS
**REFRIGERATOR
**MICROWAVE
**COUNTERTOP & BACKSPLASH
**PULL
**LOWER DRAWERS
**OVEN/RANGE
**LOWER CABINETS
**TOE KICK
5'-4"
**SHELVES8
**MIRROR
**SHOWERHEAD
**SHOWER ROD
**HAND TOWEL
**FAUCET
**DRAWERS
**PULL
**SPOUT
**BATHTUB
**TOE KICK
**CABINET
**TOILET PAPER HOLDER
1'-9" 1'-9"
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:2
:3
P M
A u to d e sk
D o c s:
Y
E L L N
P S /0 a rc h b d r.
rv t
3BR INTERIOR
ELEVATIONS
326141A610C
06/12/2026
1/4" = 1'-0"A610C
A1 BATH 01 - FRONT
1/4" = 1'-0"A610C
B2 LAUNDRY - FRONT
1/4" = 1'-0"A610C
C2 KITCHEN - REAR
1/4" = 1'-0"A610C
C3 DINING - FRONT
1/4" = 1'-0"A610C
C1 KITCHEN - FRONT
1/4" = 1'-0"A610C
B3 HALL CLOSET - LEFT
1/4" = 1'-0"A610C
B1 BATH 02
5'-5" 3'-4" 1'-4" 3'-0" 1"
**CABINETS/DRAWERS
**PULL
**COUNTERTOP & BACKSPLASH
**ABA TOE KICK
**GRAB BARS INSTALLED PER ABA
REQUIREMENTS; PROVIDE BLOCKING
**ABA FAUCET
**MIRROR
'-1
'-2
8 1/2"
2'-3" 4'-10"
M A
X
'-1
'-6
'-6
**COUNTERTOP & BACKSPLASH
**PULL
**CABINETS
**TOE KICK
**UPPER CABINETS
'-1
1'-0" 2'-0" 3'-0"
1'-6"
1'-6"
**COUNTERTOP
**DRAWER
**PULL
**TOE KICK
**CABINETS
**DISHWASHER
1'-0" 2'-0" 3'-0" 1'-6" 1'-6"
OPEN TO
BEYOND
M A
X
'-1
3'-1" 3'-0" 3'-0"
M A
X
'-1
**COUNTERTOP
**PULL
**CABINETS
**TOE KICK
3'-0" 3'-0" 3'-0"
OPEN TO
BEYOND
'-1
M A
X
'-1
'-8
'-6
'-0
2'-7" 2'-6" 2'-6" 2'-6" 3'-1" 4"
4"
**UPPER CABINETS
**REFRIGERATOR
**COUNTERTOP & BACKSPLASH
**PULL
**LOWER DRAWERS
**OVEN/RANGE
**TOE KICK
'-0
**RANGE HOOD
**FALSE DRAWER
**SWITCHES FOR RANGE HOOD & LIGHT
'-6
'-0
'-0
'-0
'-0
'-6
5'-4"
**SHELVES8
'-0
**MIRROR
**SHOWERHEAD
**SHOWER ROD
**HAND TOWEL
**FAUCET
**DRAWERS
**PULL
**SPOUT
**BATHTUB
**TOE KICK
**CABINET
**TOILET PAPER HOLDER
1'-9" 1'-9"
'-6
A
B
C
PRELIMINARY
NOT FOR
CONSTRUCTION
Not for permits, pricing or other official purposes. This document has not been completed or checked and is for general information or comment only.
YELLOWSTONE NATIONAL PARK
TITLE OF SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
JC
CADD:
BB/PS/AS
TECH. REVIEW:
LF
DATE:
A/E: FIRM
PRIME:
STANTEC
CHEYENNE, WY
SHEET
OF
P
LO
T D
A
TE
R
E V
IT
V
E R
SI
O
N
198433
:3
:4
P M
A u to d e sk
D o c s:
/1
Y
E L L N
P S a rc h b d r_ a d a .r v t
3BR ABA INTERIOR
ELEVATIONS
326141A610D
06/12/2026
1/4" = 1'-0"A610D
A1 ABA BATH 01 - FRONT
1/4" = 1'-0"A610D
B2 ABA LAUNDRY - FRONT
1/4" = 1'-0"A610D
C2 ABA KITCHEN - REAR
1/4" = 1'-0"A610D
C3 ABA DINING - FRONT
1/4" = 1'-0"A610D
C1 ABA KITCHEN - FRONT
1/4" = 1'-0"A610D
B3 ABA HALL CLOSET - LEFT
1/4" = 1'-0"A610D
B1 BATH 02 - RIGHT
File details come from the government source that posted it. Updated .