B09-Attachment_2_-_Revised_Final_Construction_Drawings_2026_08_18_Part2_0002.pdf
PDF 21 MB Posted
- Attached to
- YELL 326141 YELLOWSTONE MODULAR HOUSING
- Solicitation number
- 140P2026R0078
About this file
This file is a set of civil engineering design drawings and details for a construction project at Yellowstone National Park, specifically for Canyon Village infrastructure improvements. The project is prepared by Stantec and dated June 18, 2026.
The drawings include detailed plans and profiles for storm culvert construction, civil details for site preparation and erosion control, and utility infrastructure including water service lines, hydrant installations, and manhole specifications. Key construction elements shown include 18-inch reinforced concrete pipe (RCP) storm drains at varying slopes (0.85% and 2.02%), riprap erosion protection (Class 1, ranging from 139 to 402 square feet), stabilized temporary construction entrances with 12-inch thick angular rock and filter fabric, wattles for sediment control, construction limit fencing with tree protection, and silt fencing. Utility details encompass water line valve boxes, water meters with radio-read compatibility, thrust blocking requirements for water line fittings with minimum dimension tables, fire hydrant installations with concrete collars, manhole construction with flattop and channel configurations, and water/sewer line separation requirements maintaining minimum 10-foot horizontal separation. Site work specifications address concrete sidewalks and pads, asphalt pavement sections with aggregate base requirements, concrete curb and gutter, accessible parking stalls and signage, handrails, and wheel stops. The project drawing package is divided into multiple sheets with sheet references (C5.09, C7.01-C7.05) and includes horizontal and vertical scale notations for construction implementation.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
SD SD SD
X
X
X
X
X
X
X
X
0+80
1+00
1+64.96
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
SAN
ST ST ST ST ST ST
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
W
TR
EX WETLANDS
(TYP)
45.00 LF 18" RCP (CLASS V) @ 0.85%
SD LINE J
8" SS
8" W
18" SD
EX OVERHEAD ELEC
(TYP)
SEE SHEET 45 FOR
PROPOSED ELEC &
COMM (TYP)
794279437944
79397939
BADG
ER RD
C7.07
RIP RAP (CLASS 1)
402 SF
10' 10' 10'
10'
C7.07
RIP RAP (CLASS 1)
166 SF19'
14.2'
24'
DITCH FLOWLINE
(TYP)
30'
4'
SD LINE J
0+800+901+001+101+201+301+401+501+60
45.00 LF 18" DIA RCP (CLASS V) @ 0.85%
STA 1+00.00
INV 7938.06
STA 1+44.96
INV 7938.45
2.5" CONDUIT
2" CONDUIT
8" W
8" SS
EXISTING GRADE
PROPOSED GRADE
0+
1+
1+
.1
STSTSTSTSTSTSTST
57.00 LF 18" DIA RCP (CLASS V) @ 2.02%
SD LINE K
18" SD
79507951
BA
D
G
ER
R D
RIP RAP (CLASS 1)
139 SF
C7.07
RIP RAP (CLASS 1)
139 SF
10'5' 10'
10' 5' 10'
SD LINE K
0+90 1+00 1+10 1+20 1+30 1+40 1+50 1+60 1+70
EXISTING GRADE PROPOSED GRADE
57.00 LF 18" DIA RCP (CLASS V) @ 2.02%
STA 1+57.16
INV 7951.00
STA 1+00.00
INV 7949.85
DESIGNED: SUB SHEET NO. TITLE OF SHEET
06/18/2026 YELLOWSTONE NATIONAL PARK
CADD:
PL
O
T D
AT
E:
/1
8/
:1
AM
U
SE
R
: S
AC
KE
TT
, A
BB
Y C
:\U
SE
R S\
AS
AC
KE
TT
\S
TA
N
TE
C \C
R O
N
IN
, M
EG
H
AN
N
PS
\Y
EL
L\
D D
\3
1A
_3
4\
C
AD
V2
2D R
AW
IN
G S\
C
IV
IL
\N
E- C
AN
YO
N \C
AN
YO
N \C
5.
_C
AN
YO
N
_S
TO
R M
_C U
LV
ER
T_ P&
P.
D
W G
TECH. REVIEW:
DATE:
DRAWING NO.
OF
326141
PMIS / PKG NO.
SHEET
A/E FIRM
PRIME:
STANTEC
CHEYENNE, WY
JC
JC
198433
BB/PS/AS
C5.09
CANYON VILLAGE STORM
PLAN & PROFILE
0 10 2010
HORIZONTAL SCALE OF FEET
NOTES:
1. MAINTAIN A MINIMUM 10-FT HORIZONTAL SEPARATION BETWEEN POTABLE WATER AND SANITARY SEWER LINES.
2. CROSSING LOCATION DEPTHS IN PROFILE VIEW ARE APPROXIMATE. AS-BUILT RECORD DRAWINGS WERE USED WHEN AVAILABLE. THE CONTRACTOR SHALL POTHOLE TO CONFIRM CROSSING DEPTHS IN THE FIELD.
VERTICAL SCALE OF FEET: 1" = 2.5'
6/18/26
ROAD
NOTES:
1. A STABILIZED CONSTRUCTION INGRESS AND EGRESS IS REQUIRED AT ALL ENTRANCES/EXITS FROM PAVEMENT TO NON-PAVEMENT AREAS.
2. THE ENTRANCE SHALL BE PROPERLY GRADED TO PREVENT RUNOFF FROM LEAVING THE CONSTRUCTION SITE.
3. THE ENTRANCE SHALL BE CONSTRUCTED ON LEVEL GROUND.
4. PERIODIC TOP DRESSING WITH ADDITIONAL STONE SHALL BE PROVIDED TO ENSURE THE INTEGRITY OF THE ENTRANCE DURING CONSTRUCTION.
5. THE ENTRANCE SHALL BE INSPECTED WEEKLY AND AFTER EACH RAINFALL IN ACCORDANCE WITH SWPPP.
6. ROCK MATERIAL SHALL BE ADDED WHEN SURFACE VOIDS ARE NOT VISIBLE.
7. ALL SEDIMENT DEPOSITS ON PAVED ROADWAYS SHALL BE REMOVED IMMEDIATELY.
8. ALL MATERIALS SHALL BE REMOVED AT COMPLETION OF CONSTRUCTION.
9. SEE TECHNICAL SPECIFICATIONS SECTION 01 27 23 AND 31 25 00 FOR ADDITIONAL REQUIREMENTS.
C/L OF EXISTING
AC ROADWAY
(TYP)
TOP EDGE OF
EXISTING
AC ROADWAY (TYP)
EDGE SECTION
(APPROX) OF
EXISTING AC
ROADWAY (TYP)
3"-6" ANGULAR ROCK
(12" THICK)
FILTER FABRIC PER TECHNICAL
SPECIFICATIONS SECTION 31 25 00
SHALL BE INSTALLED UNDER ALL
AREAS OF ENTRANCE (ANGULAR ROCK)
30' MIN
PROVIDE FULL WIDTH
OF INGRESS/EGRESS
AREA (20' MIN)
R=10'
R=10'
B
NOTES:
1. PLACEMENT OF WATTLES IS SUBJECT TO EXISTING CONDITIONS AND AS DIRECTED BY
THE CONTRACTING OFFICER.
2. PLACE WATTLES AS SHOWN ON PLAN SHEETS.
3. PLACE GRAVEL BAGS OVER WATTLES WHEN STAKES CANNOT BE USED DUE TO
BEDROCK.
4. UPON DEMOBILIZATION WATTLES SHALL BE REMOVED FROM SITE. COCONUT HUSK
FROM FIBER ROLLS IS NOT TO BE SPREAD IN PLACE AS MULCHING MATERIAL.
5. SEE TECHNICAL SPECIFICATIONS SECTION 01 57 23 AND 31 25 00 FOR ADDITIONAL
REQUIREMENTS.
4' (TYP)
1'
SECTION B
PROFILE
8" DIA WATTLES
(TYP)
PLACE WATTLES
TO ELIMINATE ANY GAPS
(1' MIN) 8" DIA WATTLE (TYP)
EG
INSTALL
1"X2"X24"
WOOD STAKES
8" DIA WATTLES
BURY 1/2 DIA (TYP)
EG
INSTALL
1"X2"X24"
WOOD STAKES
C7.01
WATTLES
NOT TO SCALE
STABILIZED TEMPORARY CONSTRUCTION ENTRANCE
1.33'
1.33'
2'
48"
MIN
NOT AT DRIPLINE
AT DRIPLINE
DETAIL 'A'
NOTES:
1. USE ORANGE PLASTIC FENCING MATERIALS OR 6' CHAIN LINK.
2. CLF AND TREE PROTECTION FENCE SHALL BE A MIN OF 48" HIGH. FOR TREES WITH
DRIPLINES THAT OVERHANG THE CONSTRUCTION AREAS, THE LOCATION OF THE TREE
PROTECTION FENCE SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTING OFFICER.
3. THE DETAIL SHOWN IS FOR TREE PROTECTION. MATERIAL AND SPACING SHOWN ALSO
APPLIES TO CLF.
4. LEAVE 12" SPACING BETWEEN CONSTRUCTION LIMIT FENCE AND GROUND.
5. REMOVE CONSTRUCTION LIMIT FENCE AFTER CONSTRUCTION HAS BEEN COMPLETED.
1"X2"X4' LATH
OR AS APPROVED
BY CONTRACTING OFFICER
STAPLE NAILED
TO LATH NOT IN TREE
(3 TOTAL) PER LATH
1/4" STEEL CABLE
STRUNG THROUGH
STAPLES AND BOUND
TIGHTLY AROUND TREE
WRAP CLF
AROUND TREE
UNDER LATH
EXISTING TREE
1"X2"X4' LATH
BOUND TO TREE
SEE DETAIL 'A'
DRIP LINE
METAL FENCE POSTS @ 10' CC
LENGTH OF POST = 6' MIN
EMBEDDED DEPTH - 18' MIN
PLASTIC FENCING HEIGHT = 36" MIN
POST HEIGHT = 48" MIN
CONSTRUCTION LIMIT FENCE
CONSTRUCTION LIMIT FENCE AND TREE PROTECTION
SILT FENCE
NOTES:
1. A SILT FENCE IS A VERTICAL BARRIER OF GEOTEXTILE FABRIC DESIGNED TO REMOVE PARTICLES FROM THE WATER PASSING THROUGH IT.
2. SILT FENCES ARE PLACED AROUND INLETS, ACROSS MINOR SWALES, AND AT THE TOE OF SLOPES ADJACENT TO STREAMS AND DEVELOPED PROPERTY. SILT FENCE
USAGE SHALL BE LIMITED TO HANDLE AN AREA EQUIVALENT TO 1000 SQ-FT PER 10 FT OF FENCE. CAUTION SHOULD BE USED WHERE THE SITE SLOPE IS STEEPER THAN
1:1 H:V AND WATER FLOW RATES EXCEED 1 CU-FT. PER SECOND PER 10 FT OF FENCE.
3. THE SILT FENCE SHALL BE REBUILT AND GRADING CONTROLLED SO THAT WATER IS FILTERED UNIFORMLY ALONG THE FENCE. THE ENDS OF THE FENCE SHALL BE TAPERED UPHILL. POSTS SHALL BE DRIVEN TO A MIN. DEPTH OF 18 INCHES AT A MAX SPACING OF 8 FEET. WHERE AN 18-INCH DEPTH IS IMPOSSIBLE TO ACHIEVE, THE POSTS SHALL BE AQEQUATELY SECURED TO PREVENT OVERTURNING OF THE FENCE. THE FENCE SHALL BE ATTACHED TO THE POSTS BY WIRE, CORD, STAPLES, POCKETS, OR OTHER ACCEPTABLE MEANS. A MIN. OF 6-INCHES OF GEOTEXTILE FABRIC AT THE BOTTOM OF THE FENCE SHALL BE DRAPED INTO A TRENCH, BACKFILLED WITH SOIL AND COMPACTED. FENCE CONSTRUCTION SHALL BE ADEQUATE TO HANDLE THE STRESS OF THE SEDIMENT LOADING.
4. THE CONTRACTOR SHALL MAINTAIN THE SILT FENCE UNTIL THE FENCE IS REMOVED OR UNTIL THE PROJECT IS ACCEPTED. THE FABRIC SHOULD BE CHECKED FOR RIPS, TEARS, AND OTHER TYPES OF DETERIORATION AND REPLACED AS NEEDED. SEDIMENT DEPOSITS SHALL BE REMOVED WHEN THE DEPOSIT REACHES APPROXIMATELY ONE HALF THE HEIGHT OF THE SILT FENCE. WHEN PERMANENT SOIL EROSION CONTROL IS ACHIEVED, THE FENCE SHALL BE REMOVED AND THE ACCUMULATED
SEDIMENT SPREAD AND SEEDED.
DESIGNED: SUB SHEET NO. TITLE OF SHEET
06/18/2026 YELLOWSTONE NATIONAL PARK
CADD:
PL
O
T D
AT
E:
/1
8/
:1
AM
U
SE
R
: S
AC
KE
TT
, A
BB
Y C
:\U
SE
R S\
AS
AC
KE
TT
\S
TA
N
TE
C \C
R O
N
IN
, M
EG
H
AN
N
PS
\Y
EL
L\
D D
\3
1A
_3
4\
C
AD
V2
2D R
AW
IN
G S\
C
IV
IL
\N
E- C
AN
YO
N \C
AN
YO
N \C
7.
_D
ET
AI
LS
_1 .D
W G
TECH. REVIEW:
DATE:
DRAWING NO.
OF
326141
PMIS / PKG NO.
SHEET
A/E FIRM
PRIME:
STANTEC
CHEYENNE, WY
JC
JC
198433
BB/PS/AS
C7.01
CIVIL DETAILS
SHEET 1 OF 7
C7.02
JOINTS
CONCRETE SIDEWALKS AND PADS
NOTES:
1. PORTLAND CEMENT CONCRETE SHALL CONFORM TO THE
REQUIREMENTS OF SPECIFICATION SECTION 32 16 00.
2. CONTRACTION AND EXPANSION JOINTS SHALL COMPLY WITH
SPECIFICATION SECTIONS 03 30 00 AND 32 16 00.
3. CLASS E AGGREGATE BASE REQUIREMENTS SHALL CONFORM TO
SPECIFICATION SECTION 32 11 00.
4. NO OBSTRUCTION, SUCH AS UTILITY POLES, SIGNAL POLES AND
CONTROLS, WATER METER BOXES, PULL BOXES, ETC. ARE
ALLOWED WITHIN SIDEWALKS.
5. SUBGRADE COMPACTION SHALL CONFORM TO SPECIFICATION
SECTION 32 11 00. SCARIFY 6" MINIMUM AND COMPACT TO A
MINIMUM OF 95% RELATIVE COMPACTION (MODIFIED PROCTOR).
4" MIN. CONC.
6" MIN. CLASS E AGGREGATE
BASE COMPACTED TO 95%
MODIFIED DRY DENSITY
VARIES
SEE PLANS
ASPHALT PAVEMENT SECTION
NOTES:
1. SEE SPECIFICATION SECTION 32 12 00 FOR ADDITIONAL
DETAILS ON HOT MIX ASPHALT.
2. SUBGRADE COMPACTION SHALL CONFORM TO
SPECIFICATION SECTION 32 11 00. SCARIFY 6" MINIMUM
AND COMPACT TO A MINIMUM OF 95% RELATIVE
COMPACTION (MODIFIED PROCTOR).
3" MIN. HOT MIX ASPHALT
VARIES
SEE PLANS
SLOPE: PER
GRADING PLAN
4" MIN. CLASS E AGGREGATE
BASE COMPACTED TO 95%
MODIFIED DRY DENSITY
12" MIN. SUB-BASE (CLASS A)
COMPACTED TO 95%
MODIFIED DRY DENSITY
CONCRETE CURB & GUTTER
VALLEY PAN (V-PAN)
NOTES:
1. CONCRETE CURB AND GUTTER SHALL BE UNDERLAIN WITH 6" OF CLASS E
AGGREGATE BASE, COMPACTED TO 95% RELATIVE COMPACTION (MODIFIED
PROCTOR)
2. SUBGRADE COMPACTION SHALL CONFORM TO SPECIFICATION SECTION 32 11 00.
SCARIFY 6" MINIMUM AND COMPACT TO A MINIMUM OF 95% RELATIVE COMPACTION
(MODIFIED PROCTOR).
3. CONTRACTION AND EXPANSION JOINTS SHALL COMPLY WITH SECTION 610, FP-24.
CONTRACTION JOINTS SHALL BE CONSTRUCTED BY SAWING OR SCORING. WHEN
SCORING, A TOOL SHALL BE USED WHICH WILL LEAVE CORNERS ROUNDED AND
DESTROY AGGREGATE INTERLOCK FOR SPECIFIED MINIMUM DEPTH.
4. NO CURB AND GUTTER SHALL BE PLACED WITHOUT A FINAL FORM INSPECTION BY
THE CONTRACTING OFFICER.
5. CLASS 4000 CONCRETE SHALL BE USED, PER SECTION 32 16 00.
NOTES:
1. CONCRETE, BASE, AND SUBGRADE MATERIAL AND
PREPARATION REQUIREMENTS SHALL MATCH THE
REQUIREMENTS FOR COMBINED CURB AND GUTTER DETAIL.
2. SUBGRADE COMPACTION SHALL CONFORM TO
SPECIFICATION SECTION 32 11 00. SCARIFY 6" MINIMUM AND
COMPACT TO A MINIMUM OF 95% RELATIVE COMPACTION
(MODIFIED PROCTOR).
3. NO VALLEY GUTTER SHALL BE PLACED WITHOUT FINAL FORM
INSPECTION BY THE CONTRACTING OFFICER.
4. EDGE OF V-PAN SHALL BE PLACED 3/4" BELOW THE EDGE OF
ASPHALT (3/4" LIP)
5. WELDED WIRE FABRIC MAY BE SUBSTITUTED WITH #3 BARS @
12" O.C. EACH WAY
1.25' 1.25'
2.50'
6X6 - W1.4/W1.4
WELDED WIRE FABRIC
6" PORTLAND CONCRETE CEMENT
6" CLASS E AGGREGATE BASE COURSE
SLOPE: 14" PER FT.
SLOPE: SEE PLANS
2% MAX
6" CLASS E
AGGREGATE BASE
SEE NOTE 1.
SUBGRADE
SEE NOTE 2.
3/4" PREFORMED
EXPANSION JOINT
MATERIAL
1/8"
D /4
M
IN
D
/3 M
AX
SUBGRADE
SEE NOTE 2.
SUBGRADE
SEE NOTE 2.
SUBGRADE
SEE NOTE 5.
HANDRAIL
2"
2"
2'-10"
1"
FTG.
END VIEW
4"
2"x2" POWDER COATED
SQUARE TUBE ALUMINUM
TUBING SUPPORT POSTS
2"x2" POWDER COATED
TUBE ALUMINUM TOP
RAIL
1. 1/8-INCH WEEP HOLES ARE REQUIRED AT BOTTOMS AND LOW POINTS OF RAILS AND POSTS.
2. ALL ENDS TO BE CAPPED.
3. ALL SHARP EDGES TO BE GROUND SMOOTH.
4. SEE TECHNICAL SPECIFICATIONS SECTION 05 73 00.
NOTES:
ELEVATION VIEW
CONCRETE ABAAS RAMP (TYP.)
2"x2" POWDER COATED SQUARE TUBE
ALUMINUM SUPPORT POSTS
6'-0" O.C. TYP. GRIND SMOOTH ALL WELDS
2"x2" POWDER COATED TUBE ALUMINUM TOP RAIL WELDED TO 1/2"x1/2" POST
2"x2" POWDER COATED SQUARE TUBE
ALUMINUM BOTTOM RAIL
6"
2"x2" POWDER COATED
SQUARE TUBE ALUMINUM
BOTTOM RAILS
SEE RAILING RETURN DETAIL
FOR END TREATMENT
RAILING RETURN
12" MIN
CONCRETE
RAMP
1"
1"
THICKNESS VARIES
SEE PLAN FOR SLOPE
STAINLESS STEEL PIPE SLEEVE
DESIGNED: SUB SHEET NO. TITLE OF SHEET
06/18/2026 YELLOWSTONE NATIONAL PARK
CADD:
PL
O
T D
AT
E:
/1
8/
:1
AM
U
SE
R
: S
AC
KE
TT
, A
BB
Y C
:\U
SE
R S\
AS
AC
KE
TT
\S
TA
N
TE
C \C
R O
N
IN
, M
EG
H
AN
N
PS
\Y
EL
L\
D D
\3
1A
_3
4\
C
AD
V2
2D R
AW
IN
G S\
C
IV
IL
\N
E- C
AN
YO
N \C
AN
YO
N \C
7.
_D
ET
AI
LS
_1 .D
W G
TECH. REVIEW:
DATE:
DRAWING NO.
OF
326141
PMIS / PKG NO.
SHEET
A/E FIRM
PRIME:
STANTEC
CHEYENNE, WY
JC
JC
198433
BB/PS/AS
C7.02
CIVIL DETAILS
SHEET 2 OF 7
C7.03
SIGN INSTALLATION
NOTES:
1. STRIPING AND MARKINGS ARE REPRESENTATIVE ONLY.
2. STRIPING AND MARKING LAYOUTS SHALL BE REVIEWED AND
ACCEPTED BY CONTRACTING OFFICER PRIOR TO APPLYING
PAINT.
3. REFER TO SPECIFICATION SECTION 32 17 00.
WHITE ISA
SOLID WHITE
BLUE
BACKGROUND
4' -5
3'-10"
ACCESSIBLE PARKING SYMBOL
5"
4"
4.5" R
12.5" R
ACCESSIBLE PARKING
ONLY SIGN (R7-8)
AT STANDARD
ACCESSIBLE SPACE
ACCESSIBLE
PARKING ONLY
SIGN (R7-8)
VAN ACCESSIBLE
SIGN (R7-8B)
AT VAN
ACCESSIBLE
PARKING STALL
ONLY
ACCESSIBLE PARKING SIGNS
9"
AT VAN
ACCESSIBLE SPACE
7' M
IN
T
O G
R O
U N
D
12"
NOTES:
1. SEE PLANS FOR LAYOUT INFORMATION. PARKING AREAS SHALL
BE STAKED AND VERIFIED BY CONTRACTING OFFICER PRIOR TO
PARKING AREA CONSTRUCTION.
2. STRIPING AND MARKINGS ARE REPRESENTATIVE ONLY.
3. STRIPING AND MARKING LAYOUTS SHALL BE REVIEWED AND
ACCEPTED BY CONTRACTING OFFICER PRIOR TO APPLYING
PAINT.
4. SEE SPECIFICATIONS SECTION 32 17 00.
9' CC (CANYON)
10' CC (NE ENTRANCE)
EDGE OF PAVEMENT
4" WIDE WHITE STRIPE
(TYP) 19.5' CANYON
20' NE ENTRANCE
PARKING STALL
VAN ACCESSIBLE PARKING SIGN,
LOCATE AS SHOWN ON PLANS
4" WHITE BORDER
4" WHITE DIAGONALS, TYP.
ACCESSIBLE SYMBOL
NOTES:
1. SEE PLANS FOR LAYOUT INFORMATION. PARKING AREAS SHALL BE
STAKED AND VERIFIED BY CONTRACTING OFFICER PRIOR TO PARKING
AREA CONSTRUCTION.
2. STRIPING AND MARKINGS ARE REPRESENTATIVE ONLY.
3. STRIPING AND MARKING LAYOUTS SHALL BE REVIEWED AND
ACCEPTED BY CONTRACTING OFFICER PRIOR TO APPLYING PAINT.
4. ACCESSIBLE PARKING STALLS AND AISLES SHALL BE LEVEL WITH
SURFACE SLOPES NOT EXCEEDING 1.5% IN ALL DIRECTIONS.
5. SEE SPECIFICATIONS SECTION 32 17 00.
11' 5'
5.5'
3'
4" WIDE WHITE STRIPE (TYP)
19.5' CANYON
20' NE ENTRANCE
5'
10'
ACCESSIBLE PARKING SIGN,
LOCATE AS SHOWN ON PLANS
ACCESSIBLE PARKING STALLS
WHEEL STOP
1.5"
7"
6'
3"
5"
#4 BAR ANCHOR PINS
14" LONG (2 PER WHEEL STOP)
NOTES:
1. THE WHEEL STOPS SHALL BE ANCHORED WITH TWO (2) 14" ANCHOR
STAKES FOR CAR STOPS.
2. WHEEL STOPS SHALL BE CENTERED IN PARKING SPACES AND PLACED
TWO FEET FROM THE PARKING SPACE EDGE.
3. INSTALL PARKING WHEEL STOPS PER MANUFACTURER'S
REQUIREMENTS.
3/4" Ø OVAL THRU HOLES
REINFORCED
CONCRETE
WHEEL STOP
SIGN POST 2" X 2" SQUARE
TUBULAR STEEL PER
SECTION 718, FP-24. (SIGN
POSTS SHALL BE INSTALLED
PLUMB IN ALL DIRECTIONS)
18"
SIGN POST SIGN POST
C7.03
8"
WHEEL
STOP
2'
STOP ROADWAY MARKING
NOTES:
1. ALL MARKINGS IN WHITE TRAFFIC PAINT IN ACCORDANCE WITH THE
TECHNICAL CONDITIONS.
2. "STOP" TRAFFIC MARKING SHALL BE CENTERED ON THE STOP BAR.
3. STOP BAR SHALL START FROM CENTER LINE OF ROAD AND
CONTINUE TO EDGE OF PAVEMENT.
4. MINOR VARIATIONS IN DIMENSIONS MAY BE ACCEPTED BY THE
ENGINEER.
5. PORTIONS OF A LETTER, NUMBER, OR SYMBOL MAY BE SEPARATED
BY CONNECTIONS SEGMENTS NOT TO EXCEED 2" IN WIDTH.
6. REFER TO THE MOST RECENT VERSION OF FHWA MUTCD AND
TECHNICAL SPECIFICATIONS SECTION 32 17 00.
CL
X/2
X
8'
6'-4"
STOP BAR
EP
2'
OR
EP
4'
DESIGNED: SUB SHEET NO. TITLE OF SHEET
06/18/2026 YELLOWSTONE NATIONAL PARK
CADD:
PL
O
T D
AT
E:
/1
8/
:1
AM
U
SE
R
: S
AC
KE
TT
, A
BB
Y C
:\U
SE
R S\
AS
AC
KE
TT
\S
TA
N
TE
C \C
R O
N
IN
, M
EG
H
AN
N
PS
\Y
EL
L\
D D
\3
1A
_3
4\
C
AD
V2
2D R
AW
IN
G S\
C
IV
IL
\N
E- C
AN
YO
N \C
AN
YO
N \C
7.
_D
ET
AI
LS
_1 .D
W G
TECH. REVIEW:
DATE:
DRAWING NO.
OF
326141
PMIS / PKG NO.
SHEET
A/E FIRM
PRIME:
STANTEC
CHEYENNE, WY
JC
JC
198433
BB/PS/AS
C7.03
CIVIL DETAILS
SHEET 3 OF 7
C7.04
UTILITY TRENCH
1' 1'
NOTES:
1. PIPE BEDDING CONSISTENT WITH SECTION 704.01 OF FP-24.
2. PIPE ZONE BACKFILL (UP TO 12" OVER PIPE) IS CONSISTENT WITH PIPE BEDDING MATERIAL. PIPE ZONE BACKFILL
SHALL BE PLACED AND COMPACTED IN 6" LIFTS.
PIPE BEDDING
WATER SERVICE LINE
WATER LINE VALVE AND BOX
TAPPING SLEEVE & VALVE CONNECTION TO EX WATER LINE
SENSUS iPERL REMOTE
READER
1" SENSUS/XYLEM iPERL METER
WITH RADIO READ ANTENNA
SEE NOTE 4UTILITY MARKING TAPE
PLACE 6"-12" ABOVE PIPE
SEE SPECIFICATIONS
UTILITY MARKING TAPE
TRACER WIRE
ON TOP OF PIPE
BLUE TRACER
WIRE ON TOP
OF PIPE
TRENCH
CONTRACT OFFICER
TRENCH BACKFILL
COMPACTED PER
SPECIFICATION 31 23 00,
95% RELATIVE
COMPACTION.
CONTRACT OFFICER.
DUCTILE IRON
RESILIENT GATE
33 14 00
CONTRACT OFFICER.
CONTRACT OFFICER.
CONTRACT OFFICER.
CONTRACT OFFICER.
DUCTILE IRON
RESILIENT GATE VALVE
SEE SPECIFICATIONS 33 14 00
CONTRACT OFFICER.
CONTRACT OFFICER.
C O
N
TR
AC
T
O
FF
IC
ER
C O
N
TR
AC
CONTRACCONTRAC
C O
N
TR
AC
THERMAL
COIL METER BOX,
INSTALL PLUMB
CONTRAC
CONTRAC
NOTES
1. NO EXCEPTION TO THE MINIMUM HORIZONTAL OR VERTICAL SEPARATION REQUIREMENTS ARE PERMITTED WHEN THE SEWAGE-CARRYING PIPE IS A FORCE MAIN. SERVICE LINES MAY DEVIATE FROM THE 10' REQUIREMENT IF
APPROVED BY CONTRACTING OFFICER.
2. AT CROSSINGS, ONE FULL LENGTH OF WATER LINE PIPE SHALL BE LOCATED SO THAT BOTH JOINTS WILL BE AS FAR
FROM THE SEWER LINE AS POSSIBLE.
3. "L" IS A STANDARD LENGTH OF PIPE AS SUPPLIED BY A PIPE MANUFACTURER.
4. WHERE THE 10-FOOT HORIZONTAL SEPARATION CANNOT BE MAINTAINED, THIS SEPARATION MAY BE REDUCED, PROVIDED THE BOTTOM OF THE WATER LINE IS AT LEAST 18 INCHES HIGHER THAN THE TOP OF THE SEWER LINE
AND THE FOLLOWING ADDITIONAL REQUIREMENTS ARE MET IN ACCORDANCE WITH WPWSS;
A. THE SANITARY SEWER OR STORM DRAIN SHALL BE CONSTRUCTED OF MATERIALS AND WITH JOINTS THAT ARE
EQUIVALENT TO WATER MAIN STANDARDS OF CONSTRUCTION AND SHALL BE TESTED FOR WATER TIGHTNESS BY SEWER LINE METHODS PER SPECIFICATION 33 00 00, OR THE SANITARY SEWER, STORM SEWER, OR WATER MAIN SHALL BE PLACED IN A SEPARATE CASING PIPE. IN EITHER METHOD, THE LENGTH OF SEWER LINE OR
CASING PIPE SHALL EXTEND A MINIMUM OF 9-FEET ON EACH SIDE OF THE CROSSING, AND;
B. WATER MAINS PASSING UNDER SEWER LINES SHALL, IN ADDITION TO THE ABOVE REQUIREMENTS, BE PROTECTED BY PROVIDING ADEQUATE STRUCTURAL SUPPORT FOR THE SEWER LINE. SOIL STRUCTURAL SUPPORT SHALL CONSIST OF CEMENT TREATED BACKFILL (FLOWABLE FILL) BEARING ON UNDISTURBED SOIL.
5. WHEN THE REQUIRED HORIZONTAL AND/OR VERTICAL SEPARATIONS BETWEEN WATER LINES AND SEWER LINES CANNOT BE MET, THE SEWER MAY BE ENCASED IN ONE FOOT OF CEMENT TREATED BACKFILL (FLOWABLE FILL).
6. CEMENT TREATED BACKFILL (FLOWABLE FILL) SHALL MEET THE FOLLOWING CRITERIA:
INGREDIENTS LBS/CY
CEMENT (0.45 SACK) 42
WATER (39 GALLONS) 325
COARSE AGGREGATE (SIZE NO. 57) 1,700
SAND (ASTM C-33) 1,845
THE MAXIMUM DESIRED 28-DAY STRENGTH SHALL BE 30-60 PSI. THERE IS NO COMPACTION REQUIREMENT FOR
CEMENT TREATED BACKFILL.
7. CEMENT-TREATED FILL MATERIALS & INSTALLATION SHALL COMPLY WITH WYOMING DEQ CHAPTER 12 REGULATIONS.
CONTRAC
CONTRAC CONTRAC
C O
N T
R C
C O
N T
R C
PLACE CURB STOP AS
INDICATED ON PLANS
OR AS DIRECTED BY
CONTRACT OFFICER.
WATER AND SEWER LINE SEPARATION
2" WATER SERVICE
REDUCER AND 2" WATER SERVICE
1"
NOTES:
1. INSTALL CURB STOP AT LOCATION APPROVED BY CONTRACTING OFFICER.
2. CURB STOP BOX TO INCLUDE STATIONARY ROD (STAINLESS STEEL) AND PIN;
CONTRACTOR SHALL VERIFY LENGTH.
3. INSIDE NUT SHALL BE HELD WITH A WRENCH WHEN CONNECTION SERVICE LINES.
4. WATER METERS SHALL BE COMPATIBLE WITH THE PARK'S EXISTING FLEXNET RADIO
READ SYSTEM AND SOFTWARE.
5. THE CONTRACTOR SHALL INSTALL PRESSURE REDUCING VALVES (PRVs) ON ANY
SERVICES EXCEEDING 80 PSI OR AS DIRECTED BY THE CONTRACTING OFFICER.
6. THE CONTRACTOR WILL PROVIDE ENOUGH PRVS TO INSTALL ONE ON EACH NEW
SERVICE. AT THE TIME OF INSTALLATION AND IN THE PRESENCE OF THE
CONTRACTING OFFICER, THE CONTRACTOR WILL COMPLETE PRESSURE TESTING AT
EACH NEW SERVICE LOCATION TO CONFIRM WHETHER A PRV IS NEEDED AT THAT
LOCATION. ANY UNINSTALLED PRVs WILL BE GIVEN TO THE CONTRACTING OFFICER
AS SPARES.
COMBINATION AIR RELEASE/VACUUM VALVE
CONTRACT OFFICER.
2"
6' -0
LOCATION SHOWN ON PLANS.
(INSTALL FLUSH WITH GROUND.)
THERMAL
COIL METER BOX,
INSTALL PLUMB
INFLOW PREVENTER RATED FOR POTABLE SUPPLY PROTECTION WITH
COMBO AIR RELEASE/
VACUUM VALVE (2" DIA)
BUG SCREEN, VAL-MATIC FLOODSAFE, OR APPROVED EQUAL BY THE CONTRACT OFFICER.
REDUCER
WATER METER
DESIGNED: SUB SHEET NO. TITLE OF SHEET
08/18/2026 YELLOWSTONE NATIONAL PARK
CADD:
PL
O
T D
AT
E:
/1
8/
1:
A M
U
SE
R : S
AC
KE
TT
, A
BB
Y
C :\U
SE
R
S\
AS
AC
KE
TT
\S
TA
N
TE
C
\C R
O N
IN
, M
EG
H
AN
N
PS
\Y
EL
L\ D
D \3
1A _3
4\ C
AD
V2
2D
R
AW
IN
G
S\ C
IV
IL
\N E-
C
AN
YO
N
\C
AN
YO
N
\C 7.
_D
ET
AI
LS
_1
.D W
G
TECH. REVIEW:
DATE:
DRAWING NO.
OF
326141
PMIS / PKG NO.
SHEET
A/E FIRM
PRIME: JC
JC
198433
AS
C7.04
CIVIL DETAILS
SHEET 4 OF 7
8/18/26
8/18/26
C7.05
HYDRANT INSTALLATION
THRUST BLOCKING FOR WATER LINE FITTINGS
THRUST BLOCKING
MINIMUM THRUST BLOCK DIMENSIONS
FLATTOP MANHOLE
MANHOLE CHANNEL
CONCRETE COLLAR
UTILITY MARKING TAPE
(TYP)
BLUE TRACER WIRE
(TYP)
THRUST BLOCK
NOTES:
1. HYDRANT SHALL BE A MUELLER SUPER CENTURION 250.
2. METAL TO BE WRAPPED WITH 8 mil POLYETHYLENE.
3. TRACER WIRE SHALL BE INSTALLED PER SPECIFICATIONS.
4. FIRE HYDRANT BOLTS SHALL BE COVERED WITH 8 mil POLYETHYLENE PRIOR TO POURING CONCRETE THRUST BLOCKS.
5. FIRE HYDRANT MANUFACTURER AND PRODUCT DETAILS SHALL MEET THE REQUIREMENT OF YELLOWSTONE NP PUBLIC
WORKS/MAINTENANCE DEPARTMENT TO ENSURE CONSISTENCY FOR MAINTENANCE/REPAIR.
GROUND SURFACE (DRAIN AWAY FROM HYDRANT)
CONTRACTING OFFICER.
DIRECTION OF
TRAFFIC FLOW
COATED WITH 2 COATS
OF CONTRACTING
OFFICER APPROVED
ASPHALT SEALANT
CONCRETE COLLAR AROUND
ADJUSTING RINGS & FRAME.
SEE DETAIL 7/C7.05
24"
DESIGNED: SUB SHEET NO. TITLE OF SHEET
06/18/2026 YELLOWSTONE NATIONAL PARK
CADD:
PL
O
T D
AT
E:
/1
8/
:1
AM
U
SE
R
: S
AC
KE
TT
, A
BB
Y C
:\U
SE
R S\
AS
AC
KE
TT
\S
TA
N
TE
C \C
R O
N
IN
, M
EG
H
AN
N
PS
\Y
EL
L\
D D
\3
1A
_3
4\
C
AD
V2
2D R
AW
IN
G S\
C
IV
IL
\N
E- C
AN
YO
N \C
AN
YO
N \C
7.
_D
ET
AI
LS
_1 .D
W G
TECH. REVIEW:
DATE:
DRAWING NO.
OF
326141
PMIS / PKG NO.
SHEET
A/E FIRM
PRIME:
STANTEC
CHEYENNE, WY
JC
JC
198433
BB/PS/AS
C7.05
CIVIL DETAILS
SHEET 5 OF 7
| Sheets and Views |
| 33 CANYON VILLAGE STORM PLAN & PROFILE |
| 34 CIVIL DETAILS SHEET 1 OF 7 |
| 35 CIVIL DETAILS SHEET 2 OF 7 |
| 36 CIVIL DETAILS SHEET 3 OF 7 |
| 38 CIVIL DETAILS SHEET 5 OF 7 |
| 40 CIVIL DETAILS SHEET 7 OF 7 |
File details come from the government source that posted it. Updated .