B08_Attach_2d_NOCA_156728_100__CD_Drawings_Part4.pdf

PDF 3 MB Posted

Attached to
NOCA 156728 Stehekin WWTP Federal contract opportunity
Solicitation number
140P2023R0131
Issued by
Department of the Interior National Park Service National Office

About this file

This document contains construction drawings related to a federal solicitation for wastewater treatment plant improvements. The drawings specify requirements for installing and connecting various instrumentation and control system components at the Stehekin Wastewater Treatment Plant, including pressure gauges, switches, transmitters, sensors, antennas, and associated conduit, piping and mounting hardware. Key elements to be provided include a radio system with antenna for communications, upgrades to the existing pump controller, and modifications to the headworks control panel. The solicitation was issued by the National Park Service National Office within the Department of the Interior.

View the file

Other files for this federal contract opportunity

Other files attached to NOCA 156728 Stehekin WWTP, newest first.
File Type Posted
Sol_140P2023R0131_Amd_0004.pdf PDF
B09_Amd_03_Attach_01_140P2023R0131_QA3_0003.xlsx XLSX spreadsheet
B09_Amd_03_Attach_05_NOCA_STEHEKIN_Drawings_for_Rev_2_Structural_Updates_08-25-23_0003.pdf PDF
B09_Amd_03_Attach_04_32_62_17_Driven_Steel_Sheet_Piling_Rev_1_0003.pdf PDF
B09_Amd_03_SF30_NOCA_156728_140P2023R0131_0003.pdf PDF
B09_Amd_03_Attach_02_Solit_Clauses_Construction_REVISED_20230828_0003.docx DOCX document
B09_Amd_03_Attach_03_01_27_00_Definition_of_Contract_Line_Items_Rev_1_0003.pdf PDF
Sol_140P2023R0131_Amd_0003.pdf PDF
B09_Amd_02_Attach_08_26_28_00_Overcurrent_and_Short_Circuit_Protective_Devices_Rev_1_0002.pdf PDF
B09_Amd_02_Attach_02_Specification_01_73_20_correction_0002.pdf PDF
B09_Amd_02_Attach_09_NOCA_STEHEKIN_Drawings_for_Rev_1_Electrical_Updates_08-10-2023_0002.pdf PDF
Sol_140P2023R0131_Amd_0002.pdf PDF
B09_Amd_02_Attach_03_Specification_03_31_30_correction_0002.pdf PDF
B09_Amd_02_SF30_NOCA_156728_140P2023R0131_0002.pdf PDF
B09_Amd_02_Attach_11_Site_Visit_Sign-in_0002.pdf PDF
B09_Amd_02_Attach_10_Site_Visit_Tri_Fold_NOCA_156728_0002.docx DOCX document
B09_Amd_02_Attach_05_Specification__40_66_40_correction_0002.pdf PDF
B09_Amd_02_Attach_07_26_09_13_Electrical_Metering_Devices_Rev_1_0002.pdf PDF
B09_Amd_02_Attach_04_Specification_40_61_96_correction_0002.pdf PDF
B09_Amd_02_Attach_01_140P2023R0131_QA2_0002.xlsx XLSX spreadsheet
B09_Amd_02_Attach_06_Specification__46_53_25_correction_0002.pdf PDF
B09_Amd_01_SF30_NOCA_156728_140P2023R0131_0001.pdf PDF
Sol_140P2023R0131_Amd_0001.pdf PDF
B09_Amd_01_140P2023R0131_QA1s_0001.xlsx XLSX spreadsheet
B08_Attach_2c_NOCA_156728_100__CD_Drawings_Part3.pdf PDF
B08_Attach_2b_NOCA_156728_100__CD_Drawings_Part2.pdf PDF
B08_Attach_3_22_07_26_-_Final_Geo-tech_Report.pdf PDF
B08_Attach_6_Construction_Contract_Administration.docx DOCX document
B08_Attach_9_Solit_PSP_Vol_II_GenRefs.doc DOC document
B08_Attach_5_Const_WD_DBA_WA20230065.pdf PDF
B08_SF_1442_140P2023R0131.pdf PDF
B08_Attach_2a_NOCA_156728_100__CD_Drawings_Part1.pdf PDF
B08_Attach_1_NOCA_156728_100___CD_Specifications.pdf PDF
B08_Attach_8_Solit_PSP_Vol_I_PastPerf_REQD.docx DOCX document
B08_Attach_7_Deliverables_LmtOnSubconRpt_REQ.xlsx XLSX spreadsheet
B08_Attach_4_22_10_06_-_Geotech_Report_for_Disposal_Field_Test_Pits_-r1.pdf PDF
Sol_140P2023R0131.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GROUND

RING, TYP

TUBE

FLOW

ATTACH GROUNDING CONDUCTORS TO

FLANGE BOLTS. WHERE INSTALLED ON

NON-METALLIC PIPE, BOND GROUNDING

RINGS AND FLOW TUBE TO ELECTRICAL

GROUNDING SYSTEM

#6 AWG MINIMUM GREEN

INSULATED GROUNDING

CONDUCTOR

TRANSMITTER; MAY BE REMOTELY

MOUNTED, SEE DRAWINGS

NOTES:

1. SINGLE-PHASE, MANUAL SWITCH REQUIRED FOR EACH AC POWERED FIELD

INSTRUMENT, UNLESS OTHERWISE SPECIFIED

2. OPERATING HANDLE PAD-LOCKABLE IN OFF POSITION

3. CAST ALUMINUM NEMA 4X, WATERPROOF ENCLOSURE

4. EATON TYPE MS, OR EQUAL

5. NAME PLATE ATTACHED SECURELY. ENGRAVED WITH INSTRUMENT TAG

NUMBER AND DESCRIPTION

6. ENCLOSURES AND COMPONENTS TO BE NEMA 7, NEMA 9 RATED WHERE

INSTALLED IN HAZARDOUS RATED LOCATIONS. REFERENCE ELECTRICAL PLAN

SHEETS FOR AREA RATINGS.

NOTE 5

ON

CONDUIT TO

INSTRUMENT

TO 120VAC

POWER SOURCE

NOTES:

1. FOR PIPE 2 1/2" AND SMALLER, USE A BUSHING IN A TEE.

2. FOR DI AND PVC ALL SIZES, USE PIPE SADDLE W/ BUSHING.

3. FOR STL, AND SST PIPES 3" AND LARGER, AND PRESSURE VESSELS. USE SHOP

INSTALLED THREAD-O-LET, OR EQUAL AS SHOWN.

4. DIAPHRAGM SEAL AND FLUSHING CONNECTION REQUIRED FOR ALL SERVICES EXCEPT

AIR, FINISHED WATER, AND FILTRATE.

5. DIAPHRAGM SEAL PRESSURE SWITCH ASSEMBLY TO BE FACTORY ASSEMBLED.

6. TYPICAL FOR INSTALLATIONS WITH EITHER PRESSURE GAUGE, PRESSURE

SWITCH/TRANSMITTER OR BOTH.

1/4" FLUSHING CONNECTION

W/GAUGE COCK AND 1/4"

NPT x 3/4" FEMALE HOSE

THREAD ADAPTER

SEE NOTES 1, 2 & 3

PROCESS PIPE

1/2" NIPPLE

DIAPHRAGM SEAL

1/2" NPT FEMALE CONNECTION FOR

PRESSURE SENSOR

1/2" BALL VALVE

PRESSURE SWITCH/TRANSMITTERPRESSURE GAUGE

6"

TO LEVEL TRANSMITTER

VIA RGS CONDUIT BUSHING WELDED

TO BLIND FLANGE

6" BLIND FLANGE

GASKET

CONDUIT

DRILL 6" BLIND FLANGE

FOR 1" BUSHING

CAST IN PLACE 6"

DUCTILE IRON PIPE

SCH 40 W/ WATER STOP

FLANGE

ULTRASONIC LEVEL SENSOR

NOTES:

1. FLEX CONDUIT LENGTH TO BE SUFFICIENT TO ALLOW REMOVAL OF SENSOR.

2. USE CONDUIT EXTENSION BETWEEN BUSHING AND SENSOR IF REQUIRED TO ENSURE

BOTTOM OF SENSOR IS AT LEAST 1" BELOW TANK TOP.

PARSHALL FLUME

NO SCALE

MAGNETIC TYPE FLOW TRANSMITTER

NO SCALE

SINGLE-PHASE CONTROL DISCONNECT

NO SCALE

PRESSURE GAUGE AND PRESSURE SWITCH/TRANSMITTER

NO SCALE

ULTRASONIC LEVEL SENSOR ON CONCRETE SLAB

NO SCALE

00-Y501

00-Y501

00-Y501

00-Y501

00-Y501

00-Y501

MANUFACTURER CABLE TO

TRANSMITTER IN 3/4" FLEX

CONDUIT.

LEVEL SENSOR

FLUSH WITH

BOTTOM OF

GRATING

LEVEL SENSOR

CENTER IN GRATING

OPENING

PARSHALL FLUME

PARSHALL

FLUME

GRATING

USE RUBBER

GROMETS AND HOSE

CLAMP TO HOLD PIPE

IN PLACE

316 SS

PIPE

FLOAT SWITCH MOUNTING

NO SCALE

2" LAP

EL *

EL *

EL *

EL *

PROVIDE SLACK

IN CABLE

3/8" 316 STAINLESS

STEEL BOLTS NUTS

AND WASHERS

SUPPORT PIPE

1" 316

STAINLESS STEEL

OR PVC-80

JUNCTION BOX

LOCATED AT

WALKING SURFACE/LID

SUPPORT PIPE

1" 316 STAINLESS

STEEL OR PVC-80

TANK OR SUMP

3/8" EXPANSION

ANCHORS

MANUFACTURER STANDARD 316

MOUNTING CLAMPS

4"

5' -0

" M

AX

SP

AC

IN

G

SEE ENLARGED DETAIL

SECTION

FACE OF WALLENLARGED DETAIL

BANDS OR CLAMPS TO

POSITION FLOATS AT

DESIRED ELEVATION AND AT

12" MAXIMUM SPACING TO

SECURE CABLING

NOTE:

1. WHEN FLOATS SET CLOSER THAN 18" OF LEVEL DIFFERENCE, ROTATE FLOATS AROUND PIPE

TO AVOID INTERFERENCE.

* REFER TO SPECIFICATIONS FOR APPROXIMATE MOUNTING HEIGHTS; FIELD ADJUSTMENTS

FOR ACTUAL MOUNTING HEIGHTS SHALL BE NECESSARY

136 1416/19/23

21032716

06/19/2023

175004

NOTES:

1. PROVIDE 120VAC 15A 1P CIRCUIT BREAKER FOR POWER TO 24VDC POWER SUPPLY.

2. PROVIDE 24VDC POWER SUPPLY FOR POWER TO ETHERNET RADIO.

3. PROVIDE RADIO, MOUNTED INSIDE NEMA 3R STAINLESS STEEL ENCLOSURE ADJACENT TO LIFT

STATION ENCLOSURE.

4. PROVIDE YAGI ANTENNA, MOUNTING HEIGHT PER RADIO PATH STUDY RESULTS, AIMED TOWARD

WWTP ANTENNA.

5. PROVIDE RS-485 SERIAL DATA CONNECTION BETWEEN NEW RADIO AND EXISTING PUMP

CONTROLLER.

PANEL - NEW RADIO

NO SCALE

00-Y502

EXISTING INFLUENT LIFT STATION

NOTE:

1. PROVIDE SPACERS AS NEEDED TO AVOID FLASHING.

6' -0

" M

IN

IM

U

M

1' -0

3'

-0 " M

IN

IM

U M

1' -0

WEATHERPROOF CAP

MAST TO PROVIDE 60 DEGREE

LIGHTNING PROTECTION CONE

ANTENNA ELEVATION PER RADIO

PATH SURVEY BUT NOT LESS THAN

3'-0" ABOVE ROOF OR BUILDING

PARAPET, WHICHEVER IS HIGHER

SEAL CABLE ENTRY INTO FITTING

GROUNDING STRAP

(RUN GROUND WIRE SHORTEST ROUTE

TO GROUND SYSTEM PER SPEC 26 05 26)

WEATHERPROOF

END CONNECTION

2" ALUMINUM EY FITTING

2" ALUMINUM PIPE

SCHEDULE 80

FASTEN MAST TO EXTERIOR

WALL VIA PIPE CLAMPS

INTERMEDIATE FREQUENCY CABLE THROUGH WALL.

ROUTE TO RADIO. SEAL WALL PENETRATION IN

ACCORDANCE WITH SECTION 07 92 00. PROVIDE

DRIP LOOP IN ANTENNA CABLEM

AX

M

AX

BUILDING MOUNTED RADIO ANTENNA INSTALLATION DETAIL

NO SCALE

00-Y502

13/16 X 1" SLOTS

USE FLAT WASHERS, TYP

ANGLE IRON TYP.

U-BOLT TYP

STAINLESS STEEL

8'-6" PIPE LENGTH (5'-6"

MAX CANTILEVER ABOVE TOP BRACKET).

12'-0" PIPE LENGTH (9'-0" MAX CANTILEVER ABOVE

TOP BRACKET).

5'-6" PIPE LENGTH (2'-6"

MAX CANTILEVER ABOVE TOP BRACKET).

" M

IN

IM

U M

S

PA

C

IN

G

3 11/16"

INSULATING WASHERS

SCHEDULE 80 STAINLESS

OR ALUMINUM

INSULATING WASHERS

NOTES:

1. PROVIDE GROUNDING AND ATTACHMENT OF ANTENNAS AND CABLING IN ACCORDANCE WITH

ANTENNA DETAILS.

WALL MOUNTED ANTENNA BRACKET DETAIL

NO SCALE

00-Y502

WEATHERPROOF CAP

OMNI ANTENNA

WEATHERPROOF END

CONNECTION DRIP LOOP

SEAL CABLE ENTRY

INTO FITTING

OMNI ANTENNA ATTACHMENT DETAIL

NO SCALE

00-Y502

SEE OMNI ANTENNA

ATTACHMENT DETAIL FOR

OMNI REQUIREMENTS

NOTES 3 & 4

NOTE 1

EXISTING PUMP

CONTROLLER, NOTE 5

NOTE 2

137 1416/19/23

21032716

06/19/2023

138 1416/19/23

21032716

06/19/2023

139 1416/19/23

06/19/2023

140 1416/19/23

06/19/2023

141 1416/19/23

06/19/2023

04 - WWTP BUILDING SERIES
04--Y501 - INSTRUMENTATION DETAILS 1
04--Y502 - NSTRUMENTATION DETAILS 2
04--Y601 - NETWORK DIAGRAM
04--Y602 - WWTP CONTROL PANEL LAYOUT
04--Y603 - WWTP CONTROL PANEL POWER SCHEMATIC
04--Y604 - WWTP BUILDING HEADWORKSGO/NO-GO PANEL

File details come from the government source that posted it. Updated .