Attachment H - 1656273dwg27of29.pdf
PDF 24 MB Posted
- Solicitation number
- N6247022R0002
About this file
This solicitation is for Phase 3 Family Housing at Villaggio at Vicenza, Italy. The Naval Facilities Engineering Command is seeking offers for the construction of additional military family housing units at Villaggio. Offerors must submit proposals no later than April 27, 2022. The work includes site preparation, utilities infrastructure, and construction of 68 two-bedroom and four-bedroom townhome units. The anticipated period of performance is 730 calendar days from Notice to Proceed. The solicitation was issued on March 28, 2022 to full and open competition under standard commercial terms and conditions.
View the file
Other files
Show 40 more
Latest 50 of 61 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 743 5
A
B
Z
AA
BB
CC DD
A3
EL482
A1
EL481
A3
EP482
A1
EP481
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOM K208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOM
K208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOM
K208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSETK207
BATHROOM
K208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET K207
BATHROOM
K208
LINEN
J202
CLOSET
J205
BEDROOM
J207
MASTER BATH
J203
BEDROOM
J208
MASTER CLOSET
J201
CIRCULATION
J206
MASTER BEDROOM
J204
BATHROOM
J202
CLOSET
J205
BEDROOM
J207
MASTER BATH
J203
BEDROOM
J208
MASTER CLOSET
J201
CIRCULATION
J206
MASTER BEDROOM
J204
BATHROOM
J202
CLOSET
J205
BEDROOM
J207
MASTER BATH
J203
BEDROOM
J208
MASTER CLOSET
J201
CIRCULATION
J206
MASTER BEDROOM
J204
BATHROOM
K208
LINEN
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:2 :3
B
IM
B P
AM
E R
V ic e n za p h a se
II
I_ A F H P
TH
E e n ve lo p e .r vt
JSG JMMMVA
TH
B
LD
G
S
E C
O N
D F
LO
O
R E
LE
C
TR
IC
A L
P
LA
N P
IA
N
TA
E
LE
TT
R
IC
A T
H E
D
P
IA
N O
S E
C O
N D
O
E-163
14106875
1656273
M V A
SCALE 1 : 100
TH BUILDING 28100 SECOND FLOOR ELECTRICAL PLAN /
PIANTA ELETTRICO AP EDIFICIO 28100 PIANO SECONDO
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. /
VEDERE LE PIANTE ARCHITETTONICHE E CIVILI PER LA POSIZIONE DEGLI
EDIFICI.
A1
EL482
A1
EP482
1 2 3 4 5 6 7 8 9
A
B
C
D
E
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K006
CIRCULATION
K007
CLOSET
K006
CIRCULATION
K007
CLOSET
K006
CIRCULATION
K007
CLOSET
K006
CIRCULATION
K004
STORAGE
K007
CLOSET
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:3 :3
B
IM
B P
AM
E R
V ic e n za p h a se
II
I_ A F H P
TH
E e n ve lo p e .r vt
JSG JMMMVA
TH
B
LD
G
G
R O
U N
D F
LO
O
R E
LE
C
TR
IC
A L
P
LA
N P
IA
N
TA
E
LE
TT
R
IC
A T
H E
D
P
IA
N O
T E
R R
A
E-171
14106876
1656273
M V A
SCALE 1 : 100
TH BUILDING 28300 GROUND FLOOR ELECTRICAL PLAN /
PIANTA ELETTRICO AP EDIFICIO 28300 PIANO TERRA
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. /
A2
EL482
A2
EP482
1 2 3 4 5 6 7 8 9
A
B
C
D
E K107
BALCONY
K106
PANTRY
K105
KITCHENK104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K107
BALCONY
K106
PANTRY
K105
KITCHEN K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K107
BALCONY
K105
KITCHENK104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K107
BALCONY
K105
KITCHEN K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K106
PANTRY
K106
PANTRY
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:3 :4
B
IM
B P
AM
E R
V ic e n za p h a se
II
I_ A F H P
TH
E e n ve lo p e .r vt
JSG JMMMVA
TH
B
LD
G
F
IR
S
T
FL
O O
R E
LE
C
TR
IC
A L
P
LA
N P
IA
N
TA
E
LE
TT
R
IC
A T
H E
D
P
IA
N O
P R
IM
O
E-172
14106877
1656273
M V A
SCALE 1 : 100
TH BUILDING 28300 FIRST FLOOR ELECTRICAL PLAN /
PIANTA ELETTRICO AP EDIFICIO 28300 PIANO PRIMO
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. /
1 2 3 4 5 6 7 8 9
B
C
D
E
A3
EL482
A3
EP482
K202
BEDROOM
K201
BEDROOM
K200
CIRCULATION
K208
LINEN
K202
BEDROOMK201
BEDROOM
K208
LINEN
K202
BEDROOM K201
BEDROOM
K206
BEDROOM
K202
BEDROOMK201
BEDROOM
K206
BEDROOM
K203
MASTER BATH
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K204
MASTER CLOSET
K207
BATHROOM
K208
LINEN
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K204
MASTER CLOSET
K207
BATHROOM
K208
LINEN
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:3 :0
B
IM
B P
AM
E R
V ic e n za p h a se
II
I_ A F H P
TH
E e n ve lo p e .r vt
JSG JMMMVA
TH
B
LD
G
S
E C
O N
D F
LO
O
R E
LE
C
TR
IC
A L
P
LA
N P
IA
N
TA
E
LE
TT
R
IC
A T
H E
D
P
IA
N O
S E
C O
N D
O
E-173
14106878
1656273
M V A
SCALE 1 : 100
TH BUILDING 28300 SECOND FLOOR ELECTRICAL PLAN /
PIANTA ELETTRICO AP EDIFICIO 28300 PIANO SECONDO
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. /
H
B
C
D
E
F
G
K
L
M
Q
R
T U V W X Y Z AA
C1
EL481
C1
EL481
A1
EL482
A1
EP482
K005
GARAGE
J005
STORAGE
J006
GARAGE
J001
ENTRY
J003
LAUNDRY
J002
FOYER
J004
MECHANICAL
J007
STORAGE
J005
STORAGE
J006
GARAGE
J001
ENTRY
J003
LAUNDRY
J002
FOYER
J004
MECHANICAL
J007
STORAGE
J005
STORAGE
J006
GARAGE
J001
ENTRY
J003
LAUNDRY
J002
FOYER
J004
MECHANICAL
J007
STORAGE
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K006
CIRCULATION K000
ENTRYK008
FOYER
K004
STORAGE
K002
LAUNDRY
K007
CLOSET
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K006
CIRCULATION
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K007
CLOSET
K003
MECHANICAL
K001
ENTRY
K006
CIRCULATION
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K007
CLOSET
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K006
CIRCULATION
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K007
CLOSET
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K006
CIRCULATION
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K007
CLOSET
K005
GARAGE
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:3 :1
B
IM
B P
AM
E R
V ic e n za p h a se
II
I_ A F H P
TH
E e n ve lo p e .r vt
JSG JMMMVA
TH
B
LD
G
A
R E
A A
G R
O U
N D
F
LO
O R
E
LE
C
TR
IC
A
L P
LA
N
P
IA
N
TA
E
LE
TT
R
IC
A
T H
E D
A
R E
A A
P
IA
N O
T E
R R
A
E-181
14106879
1656273
M V A
SCALE 1 : 100
TH BUILDING 29400 AREA A GROUND FLOOR ELECTRICAL PLAN /
PIANTA ELETTRICO AP EDIFICIO 29400 PIANO TERRA
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. /
C
D
E
F
G
K
L
M
Q
R
T U V W X Y Z AA
C3
EL481
C3
EL481
A2
EL482
A2
EP482
J101
CIRCULATION
J104
LIVING
J102
HALF BATH
J103
FAMILY
J105
DINING
J106
KITCHENJ107
BALCONY
J101
CIRCULATION
J104
LIVING
J102
HALF BATH
J103
FAMILY
J105
DINING
J106
KITCHEN
J107
BALCONY
J101
CIRCULATION
J104
LIVING
J102
HALF BATH
J103
FAMILY
J105
DINING
J106
KITCHEN
J107
BALCONY
K107
BALCONY
K106
PANTRY
K105
KITCHEN
K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K107
BALCONY
K106
PANTRY
K105
KITCHEN
K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K107
BALCONY
K106
PANTRY
K105
KITCHEN
K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K107
BALCONY
K106
PANTRY
K105
KITCHEN
K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K107
BALCONY
K106
PANTRY
K105
KITCHEN
K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:3 :2
B
IM
B P
AM
E R
V ic e n za p h a se
II
I_ A F H P
TH
E e n ve lo p e .r vt
JSG JMMMVA
TH
B
LD
G
A
R E
A A
F
IR
S T
FL
O
O R
E
LE
C
TR
IC
A
L P
LA
N
P
IA
N
TA
E
LE
TT
R
IC
A
T H
E D
A
R E
A A
P
IA
N O
P R
IM
O
E-182
14106880
1656273
M V A
SCALE 1 : 100
TH BUILDING 29400 AREA A FIRST FLOOR ELECTRICAL PLAN /
PIANTA ELETTRICO AP EDIFICIO 29400 PIANO PRIMO
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. /
C
D
E
F
G
K
L
M
Q
R
T U V W X Y Z AA
A1
EL481
A1
EL481
A3
EL482
A3
EP482
J202
CLOSET
J205
BEDROOM
J207
MASTER BATH
J203
BEDROOM
J208
MASTER CLOSET
J201
CIRCULATION
J206
MASTER BEDROOM
J204
BATHROOM
J202
CLOSET
J205
BEDROOM
J207
MASTER BATH
J203
BEDROOM
J208
MASTER CLOSET
J201
CIRCULATION
J206
MASTER BEDROOM
J204
BATHROOM
J202
CLOSET
J205
BEDROOM
J207
MASTER BATH
J203
BEDROOM
J208
MASTER CLOSET
J201
CIRCULATION
J206
MASTER BEDROOM
J204
BATHROOM
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOM
K208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOMK208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOMK208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOM
K208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOM
K208
LINEN
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:3 :4
B
IM
B P
AM
E R
V ic e n za p h a se
II
I_ A F H P
TH
E e n ve lo p e .r vt
JSG JMMMVA
TH
B
LD
G
A
R E
A A
S E
C O
N D
F
LO
O R
E
LE
C
TR
IC
A
L P
LA
N
P
IA
N
TA
E
LE
TT
R
IC
A
T H
E D
A
R E
A A
P
IA
N O
S E
C O
N D
O
E-183
14106881
1656273
M V A
SCALE 1 : 100
TH BUILDING 29400 AREA A SECOND FLOOR ELECTRICAL PLAN /
PIANTA ELETTRICO AP EDIFICIO 29400 PIANO SECONDO
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. /
AA BB CC DD EE FF GG HH
KK
LL
MM
PP
RR
SS
TT
UU
VV
WW
A1
EL482
C1
EL481
C1
EP481
A1
EP482
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K006
CIRCULATION
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K007
CLOSET
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K006
CIRCULATION
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K007
CLOSET
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K006
CIRCULATION
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K007
CLOSET
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K006
CIRCULATION
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K007
CLOSET
K003
MECHANICAL
K001
ENTRY
K005
GARAGE
K006
CIRCULATION
K000
ENTRY
K008
FOYER
K004
STORAGE
K002
LAUNDRY
K007
CLOSET
J005
STORAGE
J006
GARAGE
J001
ENTRY
J003
LAUNDRY
J002
FOYER
J004
MECHANICAL
J007
STORAGE
J005
STORAGE
J006
GARAGE
J001
ENTRY
J003
LAUNDRY
J002
FOYER
J004
MECHANICAL
J007
STORAGE
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:3 :0
B
IM
B P
AM
E R
V ic e n za p h a se
II
I_ A F H P
TH
E e n ve lo p e .r vt
JSG JMMMVA
TH
B
LD
G
A
R E
A B
G R
O U
N D
F
LO
O R
E
LE
C
TR
IC
A
L P
LA
N
P
IA
N
TA
E
LE
TT
R
IC
A
T H
E D
A
R E
A B
P
IA
N O
T E
R R
A
E-185
14106882
1656273
M V A
SCALE 1 : 100
TH BUILDING 29400 AREA B GROUND FLOOR ELECTRICAL PLAN /
PIANTA ELETTRICO AP EDIFICIO 29400 ZONA B PIANO TERRA
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. /
LL
MM
PP
RR
SS
TT
UU
VV
WW
A2
EL482
C3
EL481
C3
EP481
A2
EP482
K107
BALCONY
K106
PANTRY
K105
KITCHEN
K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K107
BALCONY
K106
PANTRY
K105
KITCHEN
K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K107
BALCONY
K106
PANTRY
K105
KITCHEN
K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K107
BALCONY
K106
PANTRY
K105
KITCHEN
K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
K107
BALCONY K106
PANTRY
K105
KITCHEN
K104
DINING
K100
CIRCULATION
K101
HALF BATH
K103
LIVING
K102
FAMILY
J101
CIRCULATION
J104
LIVING
J102
HALF BATH
J103
FAMILY
J105
DINING
J106
KITCHEN
J107
BALCONY
J101
CIRCULATION
J104
LIVING
J102
HALF BATH
J103
FAMILY
J105
DINING
J106
KITCHEN
J107
BALCONY
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:3 :1
B
IM
B P
AM
E R
V ic e n za p h a se
II
I_ A F H P
TH
E e n ve lo p e .r vt
JSG JMMMVA
TH
B
LD
G
A
R E
A B
F
IR
S T
FL
O
O R
E
LE
C
TR
IC
A
L P
LA
N
P
IA
N
TA
E
LE
TT
R
IC
A
T H
E D
A
R E
A B
P
IA
N O
P R
IM
O
E-186
14106883
1656273
M V A
SCALE 1 : 100
TH BUILDING 29400 AREA B FIRST FLOOR ELECTRICAL PLAN /
PIANTA ELETTRICO AP EDIFICIO 29400 ZONA B PIANO PRIMO
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. /
LL
MM
PP
RR
SS
TT
UU
VV
WW
A3
EL482
A1
EL481
A1
EP481
A3
EP482
545 6875
K202
BEDROOM K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET K207
BATHROOM
K208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSETK207
BATHROOM
K208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM K206
BEDROOM
K204
MASTER CLOSET K207
BATHROOM
K208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATION
K205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOM
K208
LINEN
K202
BEDROOM
K201
BEDROOM
K203
MASTER BATH
K200
CIRCULATIONK205
MASTER BEDROOM
K206
BEDROOM
K204
MASTER CLOSET
K207
BATHROOM
K208
LINEN
J202
CLOSET
J205
BEDROOM
J207
MASTER BATH
J203
BEDROOM
J208
MASTER CLOSET
J201
CIRCULATION
J206
MASTER BEDROOM
J204
BATHROOM
J202
CLOSET
J205
BEDROOM
J207
MASTER BATH
J203
BEDROOM
J208
MASTER CLOSET
J201
CIRCULATION
J206
MASTER BEDROOM
J204
BATHROOM
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:3 :3
B
IM
B P
AM
E R
V ic e n za p h a se
II
I_ A F H P
TH
E e n ve lo p e .r vt
JSG JMMMVA
TH
B
LD
G
A
R E
A B
S E
C O
N D
F
LO
O R
E
LE
C
TR
IC
A
L P
LA
N
P
IA
N
TA
E
LE
TT
R
IC
A
T H
E D
A
R E
A B
P
IA
N O
S E
C O
N D
O
E-187
14106884
1656273
M V A
SCALE 1 : 100
TH BUILDING 29400 AREA B SECOND FLOOR ELECTRICAL PLAN /
PIANTA ELETTRICO AP EDIFICIO 29400 ZONA B PIANO SECONDO
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
1. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. /
C
D
E
F
G
H
J
K
2 3 4 5 6 7 8 9 10 11 12 13 14 15
1000 2050 2050
L
26.037
26.222
P07
STAIR
P01
VESTIBULE
P02
MACHINE 26.242
M
IN
M
IN
1800 MIN
M
IN
1800 MIN
M
IN
1800 MIN
26.253
9202275
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:0 :2
B
IM
B P
AM
E R
Vi c e n z a p h a s e
II
I_ A F H P A P E e n ve lo p e .r vt
JSG JMMMVA
A P
B U
IL
D
IN
G
A
N D
P
H O
TO
V
O
LT
A
IC
P
LA
N
IM
P
IA
N
TO
F O
TO
V
O
LT
A
IC
O A
P E
D
IF
IC
IO
E
EV101
14106885
1656273
M V A
SCALE 1 : 100
A2
AP BUILDING 27100 AND 28200 PHOTOVOLTAIC PLAN /
IMPIANTO FOTOVOLTAICO AP EDIFICIO 27100 E 28200
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. CONDUCT PHOTOVOLTAIC SYSTEM TEST IN THE PRESENCE OF THE
CONTRACTOR AND UTILITY PRIOR TO GRID CONNECTION. SCHEDULE AND
NOTIFY CONTRACTOR AND ALL APPLICABLE AGENCIES PRIOR TO TEST. VERIFY
PROPER SYSTEM OPERATION WITH CONTRACTOR AND PROVIDE
DOCUMENTATION TO THE CONTRACTOR. NOTIFY THE CONTRACTOR OF ANY
ISSUES DISCOVERED DURING THE TEST. / EFFETTUARE IL COLLAUDO
DELL'IMPIANTO FOTOVOLTAICO IN PRESENZA DELL'APPALTATORE E DEI
GESTORI PRIMA DEL COLLEGAMENTO ALLA RETE. PROGRAMMARE E
NOTIFICARE ALL'APPALTATORE E A TUTTI I GESTORI I TEST. VERIFICARE IL
CORRETTO FUNZIONAMENTO DEL SISTEMA E FORNIRE LA DOCUMENTAZIONE
ALL'APPALTATORE. NOTIFICARE ALL'APPALTATORE QUALSIASI PROBLEMA
RILEVATO DURANTE IL TEST.
4. REFER TO SHEET EV501 FOR PHOTOVOLTAIC DETAILS AND TO ENLARGE
PLAN VIEWS FOR ADJACENT PHOTOVOLTAIC EQUIPMENT INDICATED ON THIS
ONE-LINE DIAGRAM. / FARE RIFERIMENTO ALLA TAVOLA EV501 PER I DETTAGLI
DELL'IMPIANTO FOTOVOLTAICI E ALLA PLANIMETRIA GENERALE PER VEDERE LE
APPARECCHIATURE FOTOVOLTAICHE ADIACENTI INDICATE IN QUESTO SCHEMA
UNIFILARE.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.037 DC COMBINE PANELBOARD. / PANNELLO DI ACCOPPIAMENTO CC.
26.222 TYPICAL PV MODULE STRING DETAIL. SEE SHEET C1/EV501. / TIPICO
DETTAGLIO STRINGA FOTOVOLTAICO. VEDERE TAVOLA C1/EV501.
26.242 TO THE GROUND FLOOR. / AL PIANO TERRA.
26.253 REFER TO SHEET EV601 FOR SCHEDULE AND DIAGRAM. / FARE
RIFERIMENTO AL FOGLIO EV601 PER TABELLA E SCHEMA
5 6 7 8 10 11 12
B
C
D
E
F
G
H
J
K
26.037
800800
26.030
800 800 800 800
P02
MECHANICAL ROOM
P07
STAIR
102 5
180 0 M I N
26.242
M
IN
1800 MIN
M
IN
1800 MIN
1800 MIN
169 0
#2 2 14 103.82%
DIMENSIONE DEL
MODULO
RIFERIMENTO DI
PROGETTO
QUANTITA' DI
MODULI DELLA
STRUTTURA
PEAK
POWER
MODULO
Isc
MODULO
Vmpp
INVERTER
Pmax (AC)
INVERTER
Vmax
INVERTER
Imax (AC)
EFFICIENZA
INVERTER MAX
(AC)
INGRESSI
INVERTER
MPPT # STRINGHE # MODULI
PER
STRINGA
RAPPORTO P
INV/P PICCO MEDIA ANNUALE
PRODUZZIONE
(AC)
RAPPORTO
PERFORMANCE
BASIS OF DESIGN
MODULE SIZE /
FACILITY MODULE
QUANTITY /
PEAK
POWER /
MODULE
Isc /
MODULE
Vmpp /
INVERTER
Pmax (AC) /
INVERTER
Vmax /
INVERTER
Imax /
INVERTER MAX.
EFFICIENCY /
INVERTER
# ENTRIES
MPPT # STRINGS / # MODULES
PER STRING /
RATIO
P INV/P PEAK /
MEAN ANNUAL
PRODUCTION
(AC) /
PERFORMANCE
RATIO /
PHOTOVOLTAIC SYSTEM SCHEDULE - A2 APARTMENT BUILDING
TABELLA DEL SISTEMA FOTOVOLTAICO - A2 APPARTAMENTO
PV SYSTEM /
IMPIANTO FV 430Wp 56 24.08 kWp 10.9 A 42.7 Vdc 25550 W 1000 V 66 A 98,40% 2
#1 2 14 103.82% 26,872 kWh 76.87%
16A
16A
16A
DC COMBINER/
CORRENTE CONTINUA
COMBINER
PV SOURCE CIRCUIT/
CIRCUITO SORGENTE FOTOVOLTAICO
PV OUTPUT CIRCUIT/
CIRCUITO OUTPUT
FOTOVOLTAICO
PV STRING 14 MODULES/
STRINGA FOTOVOLTAICO 14 MODULI
MAIN DISTRIBUTION
PANEL - MDP/
PANNELLO DISTRIBUZIONE
PRINCIPALE
- MDP
INVERTER WITH SPD II
INVERTER OUTPUT
CIRCUIT/
CIRCUITO D'OUTPUT
INVERTER
DC
AC 4Ø
kWh
SPI
DDI
PV ENERGY METER /
CONTATORE ENERGIA
FOTOVOLTAICO
DDR
(1) - 2,5 mm2 IN 16 mm C.
32A
(1) - 10 mm2 IN CABLING TRAY 100x100 mm 63A (4) - 16 mm2 IN
35 mm C.
63A
40A
26.234
26.034
26.031
26.030
26.032
32A
(1) - 10 mm2 IN CABLING TRAY 100x100 mm 63A
26.042
PV STRING 14 MODULES
STRINGA FOTOVOLTAICO 14 MODULI
16A26.038
PV STRING 14 MODULES
STRINGA FOTOVOLTAICO 14 MODULI
PV STRING 14 MODULES
STRINGA FOTOVOLTAICO 14 MODULI
(1) - 10 mm2 IN CANALE PORTACAVI 100x100 mm
(1) - 10 mm2 IN
CANALE PORTACAVI
100x100 mm
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
INVERTER CON SPD II
AT ROOF / SUL TETTO
AT GROUND FLOOR / SUL PIANO TERRA
26.03526.233
26.233
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:4 :5
B
IM
B P
AM
E R
Vi c e n z a p h a s e
II
I_ A F H P A P E e n ve lo p e .r vt
JSG JMMMVA
A P
B U
IL
D
IN
G
P
H O
TO
V
O
LT
A
IC
P
LA
N
IM
P
IA
N
TO
F O
TO
V
O
LT
A
IC
O A
P E
D
IF
IC
IO
EV102
14106886
1656273
M V A
SCALE 1 : 100
B1
AP BUILDING 27200 PHOTOVOLTAIC PLAN /
IMPIANTO FOTOVOLTAICO AP EDIFICIO 27200
SCALE NOT TO SCALE
A1 PHOTOVOLTAIC SYSTEM ONE-LINE DIAGRAM / SCHEMA UNIFILARE DEL SISTEMA FOTOVOLTAICO /
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. CONDUCT PHOTOVOLTAIC SYSTEM TEST IN THE PRESENCE OF THE
CONTRACTOR AND UTILITY PRIOR TO GRID CONNECTION. SCHEDULE AND
NOTIFY CONTRACTOR AND ALL APPLICABLE AGENCIES PRIOR TO TEST. VERIFY
PROPER SYSTEM OPERATION WITH CONTRACTOR AND PROVIDE
DOCUMENTATION TO THE CONTRACTOR. NOTIFY THE CONTRACTOR OF ANY
ISSUES DISCOVERED DURING THE TEST. / EFFETTUARE IL COLLAUDO
DELL'IMPIANTO FOTOVOLTAICO IN PRESENZA DELL'APPALTATORE E DEI
GESTORI PRIMA DEL COLLEGAMENTO ALLA RETE. PROGRAMMARE E
NOTIFICARE ALL'APPALTATORE E A TUTTI I GESTORI I TEST. VERIFICARE IL
CORRETTO FUNZIONAMENTO DEL SISTEMA E FORNIRE LA DOCUMENTAZIONE
ALL'APPALTATORE. NOTIFICARE ALL'APPALTATORE QUALSIASI PROBLEMA
RILEVATO DURANTE IL TEST.
4. REFER TO SHEET EV501 FOR PHOTOVOLTAIC DETAILS AND TO ENLARGE
PLAN VIEWS FOR ADJACENT PHOTOVOLTAIC EQUIPMENT INDICATED ON THIS
ONE-LINE DIAGRAM. / FARE RIFERIMENTO ALLA TAVOLA EV501 PER I DETTAGLI
DELL'IMPIANTO FOTOVOLTAICI E ALLA PLANIMETRIA GENERALE PER VEDERE LE
APPARECCHIATURE FOTOVOLTAICHE ADIACENTI INDICATE IN QUESTO SCHEMA
UNIFILARE.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.042 PROVIDE TYPE AC RESIDUAL CURRENT DEVICE, 300 mA OF
SENSITIVITY. / FORNIRE UN DISPOSITIVO DI CORRENTE RESIDUA DI
TIPO AC, 300 mA DI SENSIBILITÀ.
26.233 DC DISCONNECTOR SWITCH. / SEZIONATORE FORNITO DI CORRENTE
CONTINUA.
26.234 AC DISCONNECTOR SWITCH. / SEZIONATORE FORNITO DI CORRENTE
ALTERNATA.
26.242 TO THE GROUND FLOOR. / AL PIANO TERRA.
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.030 PHOTOVOLTAIC ARRAY NO. 1. / ARRAY FOTOVOLTAICO NUMERO 1.
26.031 PHOTOVOLTAIC ARRAY NO. 2. / ARRAY FOTOVOLTAICO NUMERO 2.
26.032 PHOTOVOLTAIC ARRAY NO. 3. / ARRAY FOTOVOLTAICO NUMERO 3.
26.034 PROVIDE SHUNT TRIP CIRCUIT BREAKER CAPABLE OF RECEIVING
OPENING SIGNAL FROM SPI DEVICE AND ALL COMMUNICATIONS
CABLING. / FORNIRE UN INTERRUTTORE AUTOMATICO DI SGANCIO IN
GRADO DI RICEVERE IL SEGNALE DI APERTURA DAL DISPOSITIVO SPI E
DA TUTTI I CAVI DI COMUNICAZIONE.
26.035 CONTROL SIGNAL FROM MEDIUM VOLTAGE SUBSTATION. SEE SHEET
A1/EV501. / SEGNALE DI CONTROLLO DA SOTTOSTAZIONE A MEDIA
TENSIONE. VEDERE TAVOLA A1/EV501.
26.037 DC COMBINE PANELBOARD. / PANNELLO DI ACCOPPIAMENTO CC.
26.038 PHOTOVOLTAIC ARRAY NO. 4. / PV ARRAY NO. 4.
J
G F
E
D C
B A
26.032
26.241
P07
STAIR
1800 MIN
1800 M
IN
1800 M
IN
26.241
P02
MECHANICAL ROOM
1800 MIN
26.242
M
IN
26.037
DIMENSIONE DEL
MODULO
RIFERIMENTO DI
PROGETTO
QUANTITA' DI MODULI
DELLA STRUTTURA
PEAK
POWER
MODULO
Isc
MODULO
Vmpp
INVERTER
Pmax (AC)
INVERTER
Vmax
INVERTER
Imax (AC)
EFFICIENZA
INVERTER MAX (AC)
# STRINGHE # MODULI PER
STRINGA
RAPPORTO P
INV/P PICCO
MEDIA ANNUALE
PRODUZZIONE (AC)
RAPPORTO
PERFORMANCE
BASIS OF DESIGN
MODULE SIZE /
FACILITY MODULE
QUANTITY /
PEAK
POWER /
MODULE
Isc /
MODULE
Vmpp /
INVERTER
Pmax (AC) /
INVERTER
Vmax /
INVERTER
Imax /
INVERTER MAX.
EFFICIENCY /
# STRINGS / # MODULES PER
STRING /
RATIO
P INV/P PEAK /
MEAN ANNUAL
PRODUCTION (AC) /
PERFORMANCE
RATIO /
PHOTOVOLTAIC SYSTEM SCHEDULE - A1 APARTMENT BUILDING
TABELLA DEL SISTEMA FOTOVOLTAICO - A1 APPARTAMENTO
PV SYSTEM /
IMPIANTO FV 430Wp 105 45.15 kWp 10.9 A 42.7 Vdc 39000 W 900 V 85 A 95.60% 7 15 77.52% 42,561 kWh 64.93%
DC COMBINER/
CORRENTE CONTINUA
COMBINER
PV SOURCE CIRCUIT/
CIRCUITO SORGENTE
FOTOVOLTAICO
PV OUTPUT CIRCUIT/
CIRCUITO OUTPUT
FOTOVOLTAICO
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
MAIN DISTRIBUTION
PANEL - MDP/
PANNELLO DISTRIBUZIONE
PRINCIPALE
- MDP
INVERTER WITH SPD II/
INVERTER CON SPD II
INVERTER OUTPUT
CIRCUIT/
CIRCUITO D'OUTPUT
INVERTER
DC
AC 4Ø
kWh
SPI
DDI
PV ENERGY METER /
CONTATORE ENERGIA
FOTOVOLTAICO
DDR
26.014
(1) - 2,5 mm2 IN 16 mm C.
125A
(1) - 35 mm2 IN CABLIE TRAY 100x100 mm 125A
(4) - 25 mm2 IN 35 mm C.
125A
63A
26.234
26.042
26.030
26.031
26.032
26.038
26.039
26.112
16A
16A
16A
16A
16A
16A
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
(1) - 35 mm2 IN
CANALE PORTACAVI
100x100 mm
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
26.112 16A
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
(1) - 2,5 mm2 IN 16 mm C.
AT GROUND FLOOR / SUL PIANO TERRAAT GROUND FLOOR / SUL PIANO TERRA
26.034
26.03526.233
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:1 :0
B
IM
B P
AM
E R
Vi c e n z a p h a s e
II
I_ A F H P A P E e n ve lo p e .r vt
JSG JMMMVA
A P
B U
IL
D
IN
G
P
H O
TO
V
O
LT
A
IC
P
LA
N
IM
P
IA
N
TO
F O
TO
V
O
LT
A
IC
O A
P E
D
IF
IC
IO
EV103
14106887
1656273
M V A
SCALE 1 : 100
B1
AP BUILDING 27300 PHOTOVOLTAIC PLAN /
IMPIANTO FOTOVOLTAICO AP EDIFICIO 27300
SCALE NOT TO SCALE
A1 PHOTOVOLTAIC SYSTEM ONE-LINE DIAGRAM / SCHEMA UNIFILARE DEL SISTEMA FOTOVOLTAICO /
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. CONDUCT PHOTOVOLTAIC SYSTEM TEST IN THE PRESENCE OF THE
CONTRACTOR AND UTILITY PRIOR TO GRID CONNECTION. SCHEDULE AND
NOTIFY CONTRACTOR AND ALL APPLICABLE AGENCIES PRIOR TO TEST. VERIFY
PROPER SYSTEM OPERATION WITH CONTRACTOR AND PROVIDE
DOCUMENTATION TO THE CONTRACTOR. NOTIFY THE CONTRACTOR OF ANY
ISSUES DISCOVERED DURING THE TEST. / EFFETTUARE IL COLLAUDO
DELL'IMPIANTO FOTOVOLTAICO IN PRESENZA DELL'APPALTATORE E DEI
GESTORI PRIMA DEL COLLEGAMENTO ALLA RETE. PROGRAMMARE E
NOTIFICARE ALL'APPALTATORE E A TUTTI I GESTORI I TEST. VERIFICARE IL
CORRETTO FUNZIONAMENTO DEL SISTEMA E FORNIRE LA DOCUMENTAZIONE
ALL'APPALTATORE. NOTIFICARE ALL'APPALTATORE QUALSIASI PROBLEMA
RILEVATO DURANTE IL TEST.
4. REFER TO SHEET EV501 FOR PHOTOVOLTAIC DETAILS AND TO ENLARGE
PLAN VIEWS FOR ADJACENT PHOTOVOLTAIC EQUIPMENT INDICATED ON THIS
ONE-LINE DIAGRAM. / FARE RIFERIMENTO ALLA TAVOLA EV501 PER I DETTAGLI
DELL'IMPIANTO FOTOVOLTAICI E ALLA PLANIMETRIA GENERALE PER VEDERE LE
APPARECCHIATURE FOTOVOLTAICHE ADIACENTI INDICATE IN QUESTO SCHEMA
UNIFILARE.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.039 PHOTOVOLTAIC ARRAY NO. 5. / PV ARRAY NO. 5.
26.042 PROVIDE TYPE AC RESIDUAL CURRENT DEVICE, 300 mA OF
SENSITIVITY. / FORNIRE UN DISPOSITIVO DI CORRENTE RESIDUA DI
TIPO AC, 300 mA DI SENSIBILITÀ.
26.112 PHOTOVOLTAIC ARRAY NO. 6. / ARRAY FOTOVOLTAICO NUMERO 6.
26.233 DC DISCONNECTOR SWITCH. / SEZIONATORE FORNITO DI CORRENTE
CONTINUA.
26.234 AC DISCONNECTOR SWITCH. / SEZIONATORE FORNITO DI CORRENTE
ALTERNATA.
26.241 PHOTOVOLTAIC ARRAY NO. 7. / ARRAY FOTOVOLTAICO NUMERO 7.
26.242 TO THE GROUND FLOOR. / AL PIANO TERRA.
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.014 INVERTER MUST BE CONFIGURED SUCH THAT RAPID SHUTDOWN OF
PV PRODUCTION OCCURS UPON LOSS OF UTILITY POWER OR
OPERATION OF DISCONNECTING MEANS. / L'INVERTER DEVE ESSERE
CONFIGURATO IN MODO TALE CHE LA PRODUZIONE DI PV SI ARRESTI
RAPIDAMENTE IN CASO DI PERDITA DI POTENZA DI RETE O DI
FUNZIONAMENTO DEI MEZZI DI DISINSERIMENTO.
26.030 PHOTOVOLTAIC ARRAY NO. 1. / ARRAY FOTOVOLTAICO NUMERO 1.
26.031 PHOTOVOLTAIC ARRAY NO. 2. / ARRAY FOTOVOLTAICO NUMERO 2.
26.032 PHOTOVOLTAIC ARRAY NO. 3. / ARRAY FOTOVOLTAICO NUMERO 3.
26.034 PROVIDE SHUNT TRIP CIRCUIT BREAKER CAPABLE OF RECEIVING
OPENING SIGNAL FROM SPI DEVICE AND ALL COMMUNICATIONS
CABLING. / FORNIRE UN INTERRUTTORE AUTOMATICO DI SGANCIO IN
GRADO DI RICEVERE IL SEGNALE DI APERTURA DAL DISPOSITIVO SPI E
DA TUTTI I CAVI DI COMUNICAZIONE.
26.035 CONTROL SIGNAL FROM MEDIUM VOLTAGE SUBSTATION. SEE SHEET
A1/EV501. / SEGNALE DI CONTROLLO DA SOTTOSTAZIONE A MEDIA
TENSIONE. VEDERE TAVOLA A1/EV501.
A
B
F
G
H
J
K
C
D
78101112
E
0 0
M I N
1800 MIN
800800800800
M
IN
800 800
26.030 26.031 26.032
26.222
26.037
26.242
1800 MIN
1800 MIN
#2 2 14 103.82%
DIMENSIONE DEL
MODULO
RIFERIMENTO DI
PROGETTO
QUANTITA' DI MODULI
DELLA STRUTTURA
PEAK
POWER
MODULO
Isc
MODULO
Vmpp
INVERTER
Pmax (AC)
INVERTER
Vmax
INVERTER
Imax (AC)
EFFICIENZA
INVERTER MAX (AC)
INGRESSI
INVERTER
MPPT # STRINGHE # MODULI PER
STRINGA
RAPPORTO P
INV/P PICCO
MEAN ANNUAL
PRODUCTION (AC)
PERFORMANCE
RATIO
BASIS OF DESIGN
MODULE SIZE /
FACILITY MODULE
QUANTITY /
PEAK
POWER /
MODULE
Isc /
MODULE
Vmpp /
INVERTER
Pmax (AC) /
INVERTER
Vmax /
INVERTER
Imax /
INVERTER MAX.
EFFICIENCY /
INVERTER
# ENTRIES /
MPPT # STRINGS / # MODULES PER
STRING /
RATIO
P INV/P PEAK /
MEAN ANNUAL
PRODUCTION (AC) /
PERFORMANCE Ratio /
PHOTOVOLTAIC SYSTEM SCHEDULE - A2 APARTMENT BUILDING
TABELLA DEL SISTEMA FOTOVOLTAICO - A2 APPARTAMENTO
PV SYSTEM /
IMPIANTO FV 430Wp 56 24.08 kWp 10.9 A 42.7 Vdc 25550 W 1000 V 66 A 98,40% 2
#1 2 14 103.82%
26.872 kWh 76.87% Approximate value
16A
16A
16A
DC COMBINER/
CORRENTE CONTINUA
COMBINER
PV SOURCE CIRCUIT/
CIRCUITO SORGENTE FOTOVOLTAICO
PV OUTPUT CIRCUIT/
CIRCUITO OUTPUT
FOTOVOLTAICO
PV STRING 14 MODULES/
STRINGA FOTOVOLTAICO 14 MODULI
MAIN DISTRIBUTION
PANEL - MDP/
PANNELLO DISTRIBUZIONE
PRINCIPALE
- MDP
INVERTER WITH SPD II
INVERTER OUTPUT
CIRCUIT/
CIRCUITO D'OUTPUT
INVERTER
DC
AC 4Ø
kWh
SPI
DDI
PV ENERGY METER /
CONTATORE ENERGIA
FOTOVOLTAICO
DDR
(1) - 2,5 mm2 IN 16 mm C.
32A
(1) - 10 mm2 IN CABLING TRAY 100x100 mm 63A (4) - 16 mm2 IN
35 mm C.
63A
40A
26.234
26.034
26.031
26.030
26.032
32A
(1) - 10 mm2 IN CABLING TRAY 100x100 mm 63A
26.042
PV STRING 14 MODULES
STRINGA FOTOVOLTAICO 14 MODULI
16A26.038
PV STRING 14 MODULES
STRINGA FOTOVOLTAICO 14 MODULI
PV STRING 14 MODULES
STRINGA FOTOVOLTAICO 14 MODULI
(1) - 10 mm2 IN CANALE PORTACAVI 100x100 mm
(1) - 10 mm2 IN
CANALE PORTACAVI
100x100 mm
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
INVERTER CON SPD II
AT ROOF / SUL TETTO
AT GROUND FLOOR / SUL PIANO TERRA
26.03526.233
26.233
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:0 :0
B
IM
B P
AM
E R
Vi c e n z a p h a s e
II
I_ A F H P A P E e n ve lo p e .r vt
JSG JMMMVA
A P
B U
IL
D
IN
G
P
H O
TO
V
O
LT
A
IC
P
LA
N
IM
P
IA
N
TO
F O
TO
V
O
LT
A
IC
O A
P E
D
IF
IC
IO
EV105
14106888
1656273
M V A
SCALE 1 : 100
B1 AP BUILDING 28400 PHOTOVOLTAIC PLAN / IMPIANTO FOTOVOLTAICO AP EDIFICIO 28400 /
SCALE NOT TO SCALE
A1 PHOTOVOLTAIC SYSTEM ONE-LINE DIAGRAM / SCHEMA UNIFILARE DEL SISTEMA FOTOVOLTAICO /
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. CONDUCT PHOTOVOLTAIC SYSTEM TEST IN THE PRESENCE OF THE
CONTRACTOR AND UTILITY PRIOR TO GRID CONNECTION. SCHEDULE AND
NOTIFY CONTRACTOR AND ALL APPLICABLE AGENCIES PRIOR TO TEST. VERIFY
PROPER SYSTEM OPERATION WITH CONTRACTOR AND PROVIDE
DOCUMENTATION TO THE CONTRACTOR. NOTIFY THE CONTRACTOR OF ANY
ISSUES DISCOVERED DURING THE TEST. / EFFETTUARE IL COLLAUDO
DELL'IMPIANTO FOTOVOLTAICO IN PRESENZA DELL'APPALTATORE E DEI
GESTORI PRIMA DEL COLLEGAMENTO ALLA RETE. PROGRAMMARE E
NOTIFICARE ALL'APPALTATORE E A TUTTI I GESTORI I TEST. VERIFICARE IL
CORRETTO FUNZIONAMENTO DEL SISTEMA E FORNIRE LA DOCUMENTAZIONE
ALL'APPALTATORE. NOTIFICARE ALL'APPALTATORE QUALSIASI PROBLEMA
RILEVATO DURANTE IL TEST.
4. REFER TO SHEET EV501 FOR PHOTOVOLTAIC DETAILS AND TO ENLARGE
PLAN VIEWS FOR ADJACENT PHOTOVOLTAIC EQUIPMENT INDICATED ON THIS
ONE-LINE DIAGRAM. / FARE RIFERIMENTO ALLA TAVOLA EV501 PER I DETTAGLI
DELL'IMPIANTO FOTOVOLTAICI E ALLA PLANIMETRIA GENERALE PER VEDERE LE
APPARECCHIATURE FOTOVOLTAICHE ADIACENTI INDICATE IN QUESTO SCHEMA
UNIFILARE.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.233 DC DISCONNECTOR SWITCH. / SEZIONATORE FORNITO DI CORRENTE
CONTINUA.
26.234 AC DISCONNECTOR SWITCH. / SEZIONATORE FORNITO DI CORRENTE
ALTERNATA.
26.242 TO THE GROUND FLOOR. / AL PIANO TERRA.
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.030 PHOTOVOLTAIC ARRAY NO. 1. / ARRAY FOTOVOLTAICO NUMERO 1.
26.031 PHOTOVOLTAIC ARRAY NO. 2. / ARRAY FOTOVOLTAICO NUMERO 2.
26.032 PHOTOVOLTAIC ARRAY NO. 3. / ARRAY FOTOVOLTAICO NUMERO 3.
26.034 PROVIDE SHUNT TRIP CIRCUIT BREAKER CAPABLE OF RECEIVING
OPENING SIGNAL FROM SPI DEVICE AND ALL COMMUNICATIONS
CABLING. / FORNIRE UN INTERRUTTORE AUTOMATICO DI SGANCIO IN
GRADO DI RICEVERE IL SEGNALE DI APERTURA DAL DISPOSITIVO SPI E
DA TUTTI I CAVI DI COMUNICAZIONE.
26.035 CONTROL SIGNAL FROM MEDIUM VOLTAGE SUBSTATION. SEE SHEET
A1/EV501. / SEGNALE DI CONTROLLO DA SOTTOSTAZIONE A MEDIA
TENSIONE. VEDERE TAVOLA A1/EV501.
26.037 DC COMBINE PANELBOARD. / PANNELLO DI ACCOPPIAMENTO CC.
26.038 PHOTOVOLTAIC ARRAY NO. 4. / PV ARRAY NO. 4.
26.042 PROVIDE TYPE AC RESIDUAL CURRENT DEVICE, 300 mA OF SENSITIVITY.
/ FORNIRE UN DISPOSITIVO DI CORRENTE RESIDUA DI TIPO AC, 300 mA
DI SENSIBILITÀ.
26.222 TYPICAL PV MODULE STRING DETAIL. SEE SHEET C1/EV501. / TIPICO
DETTAGLIO STRINGA FOTOVOLTAICO. VEDERE TAVOLA C1/EV501.
4 3 2 156789121314151617
L
J
K
G
H
F
D
B
A
C
E
1800 MIN
M
IN
26.037
26.030
26.031
26.03226.032
2050 1800 MIN1000
M
IN
M
IN
M
IN
26.242
1800 MIN
26.254
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:1 :0
B
IM
B P
AM
E R
Vi c e n z a p h a s e
II
I_ A F H P A P E e n ve lo p e .r vt
JSG JMMMVA
A P
B U
IL
D
IN
G
A
N D
P
H O
TO
V
O
LT
A
IC
P
LA
N
IM
P
IA
N
TO
F O
TO
V
O
LT
A
IC
O A
P E
D
IF
IC
IO
E
EV106
14106889
1656273
M V A
SCALE 1 : 100
A2
AP BUILDING 28500 AND 29300 PHOTOVOLTAIC PLAN /
IMPIANTO FOTOVOLTAICO AP EDIFICIO 28500 E 29300
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. CONDUCT PHOTOVOLTAIC SYSTEM TEST IN THE PRESENCE OF THE
CONTRACTOR AND UTILITY PRIOR TO GRID CONNECTION. SCHEDULE AND
NOTIFY CONTRACTOR AND ALL APPLICABLE AGENCIES PRIOR TO TEST. VERIFY
PROPER SYSTEM OPERATION WITH CONTRACTOR AND PROVIDE
DOCUMENTATION TO THE CONTRACTOR. NOTIFY THE CONTRACTOR OF ANY
ISSUES DISCOVERED DURING THE TEST. / EFFETTUARE IL COLLAUDO
DELL'IMPIANTO FOTOVOLTAICO IN PRESENZA DELL'APPALTATORE E DEI
GESTORI PRIMA DEL COLLEGAMENTO ALLA RETE. PROGRAMMARE E
NOTIFICARE ALL'APPALTATORE E A TUTTI I GESTORI I TEST. VERIFICARE IL
CORRETTO FUNZIONAMENTO DEL SISTEMA E FORNIRE LA DOCUMENTAZIONE
ALL'APPALTATORE. NOTIFICARE ALL'APPALTATORE QUALSIASI PROBLEMA
RILEVATO DURANTE IL TEST.
4. REFER TO SHEET EV501 FOR PHOTOVOLTAIC DETAILS AND TO ENLARGE
PLAN VIEWS FOR ADJACENT PHOTOVOLTAIC EQUIPMENT INDICATED ON THIS
ONE-LINE DIAGRAM. / FARE RIFERIMENTO ALLA TAVOLA EV501 PER I DETTAGLI
DELL'IMPIANTO FOTOVOLTAICI E ALLA PLANIMETRIA GENERALE PER VEDERE LE
APPARECCHIATURE FOTOVOLTAICHE ADIACENTI INDICATE IN QUESTO SCHEMA
UNIFILARE.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.030 PHOTOVOLTAIC ARRAY NO. 1. / ARRAY FOTOVOLTAICO NUMERO 1.
26.031 PHOTOVOLTAIC ARRAY NO. 2. / ARRAY FOTOVOLTAICO NUMERO 2.
26.032 PHOTOVOLTAIC ARRAY NO. 3. / ARRAY FOTOVOLTAICO NUMERO 3.
26.037 DC COMBINE PANELBOARD. / PANNELLO DI ACCOPPIAMENTO CC.
26.242 TO THE GROUND FLOOR. / AL PIANO TERRA.
26.254 REFER TO SHEET EV606 FOR SCHEDULE AND DIAGRAM. / FARE
RIFERIMENTO AL FOGLIO EV606 PER TABELLA E SCHEMA
L
K
J
H
G
F
E
D
C
B
A
1716151413121110987654321
M
IN
1800 MIN
1800 MIN
M
IN
1800 MIN
1800 MIN
1800 MIN
1800 MIN
26.222
26.030
26.037
26.031
26.032
26.242
1800 MIN
26.255
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:1 :2
B
IM
B P
AM
E R
Vi c e n z a p h a s e
II
I_ A F H P A P E e n ve lo p e .r vt
JSG JMMMVA
A P
B U
IL
D
IN
G
P
H O
TO
V
O
LT
A
IC
P
LA
N
IM
P
IA
N
TO
F O
TO
V
O
LT
A
IC
O A
P E
D
IF
IC
IO
EV107
14106890
1656273
M V A
SCALE 1 : 100
A2
AP BUILDING 29100 PHOTOVOLTAIC PLAN /
IMPIANTO FOTOVOLTAICO AP EDIFICIO 29100
1. SEE SHEETS E-001 TO E-004 FOR LEGENDS, NOTES AND ABBREVIATIONS. /
VEDERE TAVOLA E-001 E E-004 PER LE LEGENDE, NOTE GENERALI E
ABBREVIAZIONI.
2. SEE ARCHITECTURAL AND CIVIL PLANS FOR LOCATIONS OF BUILDINGS. / PER
LA LOCALIZZAZIONE DEGLI EDIFICI VEDERE LE TAVOLE ARCHITETTONICHE E
CIVILI.
3. CONDUCT PHOTOVOLTAIC SYSTEM TEST IN THE PRESENCE OF THE
CONTRACTOR AND UTILITY PRIOR TO GRID CONNECTION. SCHEDULE AND
NOTIFY CONTRACTOR AND ALL APPLICABLE AGENCIES PRIOR TO TEST. VERIFY
PROPER SYSTEM OPERATION WITH CONTRACTOR AND PROVIDE
DOCUMENTATION TO THE CONTRACTOR. NOTIFY THE CONTRACTOR OF ANY
ISSUES DISCOVERED DURING THE TEST. / EFFETTUARE IL COLLAUDO
DELL'IMPIANTO FOTOVOLTAICO IN PRESENZA DELL'APPALTATORE E DEI
GESTORI PRIMA DEL COLLEGAMENTO ALLA RETE. PROGRAMMARE E
NOTIFICARE ALL'APPALTATORE E A TUTTI I GESTORI I TEST. VERIFICARE IL
CORRETTO FUNZIONAMENTO DEL SISTEMA E FORNIRE LA DOCUMENTAZIONE
ALL'APPALTATORE. NOTIFICARE ALL'APPALTATORE QUALSIASI PROBLEMA
RILEVATO DURANTE IL TEST.
4. REFER TO SHEET EV501 FOR PHOTOVOLTAIC DETAILS AND TO ENLARGE
PLAN VIEWS FOR ADJACENT PHOTOVOLTAIC EQUIPMENT INDICATED ON THIS
ONE-LINE DIAGRAM. / FARE RIFERIMENTO ALLA TAVOLA EV501 PER I DETTAGLI
DELL'IMPIANTO FOTOVOLTAICI E ALLA PLANIMETRIA GENERALE PER VEDERE LE
APPARECCHIATURE FOTOVOLTAICHE ADIACENTI INDICATE IN QUESTO SCHEMA
UNIFILARE.
GENERAL SHEET NOTES/
NOTE GENERALI DI QUESTO FOGLIO:
SHEET KEYNOTES /
NOTE CHIAVE DELLA TAVOLA:
26.030 PHOTOVOLTAIC ARRAY NO. 1. / ARRAY FOTOVOLTAICO NUMERO 1.
26.031 PHOTOVOLTAIC ARRAY NO. 2. / ARRAY FOTOVOLTAICO NUMERO 2.
26.032 PHOTOVOLTAIC ARRAY NO. 3. / ARRAY FOTOVOLTAICO NUMERO 3.
26.037 DC COMBINE PANELBOARD. / PANNELLO DI ACCOPPIAMENTO CC.
26.222 TYPICAL PV MODULE STRING DETAIL. SEE SHEET C1/EV501. / TIPICO
DETTAGLIO STRINGA FOTOVOLTAICO. VEDERE TAVOLA C1/EV501.
26.242 TO THE GROUND FLOOR. / AL PIANO TERRA.
26.255 REFER TO SHEET EV6067 FOR SCHEDULE AND DIAGRAM. / FARE
RIFERIMENTO AL FOGLIO EV607 PER TABELLA E SCHEMA
A
C D
E F G
H J
CORRIDOR
MECHANICAL ROOM
CORRIDOR
STAIR
M
IN
1800 MIN
1800 M
IN
26.037
26.241
26.030
26.031
26.241 26.242
26.032
26.037
M
IN
1800 MIN
DIMENSIONE DEL
MODULO
RIFERIMENTO DI
PROGETTO
QUANTITA' DI MODULI
DELLA STRUTTURA
PEAK
POWER
MODULO
Isc
MODULO
Vmpp
INVERTER
Pmax (AC)
INVERTER
Vmax
INVERTER
Imax (AC)
EFFICIENZA
INVERTER MAX (AC)
# STRINGHE # MODULI PER
STRINGA
RAPPORTO P
INV/P PICCO
MEAN ANNUAL
PRODUCTION (AC)
PERFORMANCE
RATIO
BASIS OF DESIGN
MODULE SIZE /
FACILITY MODULE
QUANTITY /
PEAK
POWER /
MODULE
Isc /
MODULE
Vmpp /
INVERTER
Pmax (AC) /
INVERTER
Vmax /
INVERTER
Imax /
INVERTER MAX.
EFFICIENCY /
# STRINGS / # MODULES PER
STRING /
RATIO
P INV/P PEAK /
MEAN ANNUAL
PRODUCTION (AC) /
PERFORMANCE Ratio /
PHOTOVOLTAIC SYSTEM SCHEDULE - A3 APARTMENT BUILDING
TABELLA DEL SISTEMA FOTOVOLTAICO - A3 APPARTAMENTO
PV SYSTEM /
IMPIANTO FV 430Wp 105 45.15 kWp 10.9 A 42.7 Vdc 39000 W 900 V 85 A 95.60% 7 15 77.52% 42.561 kWh 64.93%
DC COMBINER/
CORRENTE CONTINUA
COMBINER
PV SOURCE CIRCUIT/
CIRCUITO SORGENTE
FOTOVOLTAICO
PV OUTPUT CIRCUIT/
CIRCUITO OUTPUT
FOTOVOLTAICO
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
MAIN DISTRIBUTION
PANEL - MDP/
PANNELLO DISTRIBUZIONE
PRINCIPALE
- MDP
INVERTER WITH SPD II/
INVERTER CON SPD II
INVERTER OUTPUT
CIRCUIT/
CIRCUITO D'OUTPUT
INVERTER
DC
AC 4Ø
kWh
SPI
DDI
PV ENERGY METER /
CONTATORE ENERGIA
FOTOVOLTAICO
DDR
26.014
(1) - 2,5 mm2 IN 16 mm C.
125A
(1) - 35 mm2 IN CABLIE TRAY 100x100 mm 125A
(4) - 25 mm2 IN 35 mm C.
125A
63A
26.234
26.042
26.030
26.031
26.032
26.038
26.039
26.112
16A
16A
16A
16A
16A
16A
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
(1) - 35 mm2 IN
CANALE PORTACAVI
100x100 mm
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
(1) - 2,5 mm2 IN 16 mm C.
26.112 16A
PV STRING 15 MODULES/
STRINGA FOTOVOLTAICO 15 MODULI
(1) - 2,5 mm2 IN 16 mm C.
AT GROUND FLOOR / SUL PIANO TERRAAT GROUND FLOOR / SUL PIANO TERRA
26.034
26.03526.233
KEYPLAN / PIANO STRATEGICO
NAPOLI
PADOVA
BOLOGNA
= BLDG LOCATIONS
= SIMILAR BLDGS
PLAN
NORTH
1:100
0 1 32 4 5 10
SCALE:
D A
TE
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:2 :5
B
IM
B P
AM
E R
Vi c e n z a p h a s e
II
I_ A F H P A P E e n ve lo p e .r vt
JSG JMMMVA
A P
B U
IL
D
IN
G
P
H O
TO
V
O
LT
A
IC
P
LA
N
IM
P
IA
N
TO
F O
TO
V
O
LT
A
IC
O A
P E
D
IF
IC
IO
EV108
14106891
1656273
M V A
SCALE 1 : 100
B1
AP BUILDING 29200 PHOTOVOLTAIC PLAN /
IMPIANTO FOTOVOLTAICO AP EDIFICIO 29200
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .