Attachment H - 1656273dwg11of29.pdf

PDF 27 MB Posted

Attached to
P-91331, Phase 3 Family Housing Villaggio at Vicenza, Italy
Solicitation number
N6247022R0002
Issued by

About this file

This solicitation is for Phase 3 Family Housing at Villaggio, Vicenza, Italy. The Naval Facilities Engineering Command is seeking offers for the construction of additional military family housing units at Villaggio in Vicenza. Offerors must submit proposals no later than May 2, 2022. The work includes providing all labor, materials, equipment, and supervision to complete construction of approximately 80 family housing units in 5 buildings. The units will be 2-3 bedroom apartments ranging from 65 to 110 square meters. The construction must meet all applicable military construction standards and be completed within 720 calendar days of award. The awarded firm will be responsible for all associated site work, utilities, landscaping, and community amenities.

View the file

Other files

File Type Posted
Revised Attachment E - Schedule B Price Proposal Form_16JUN2022.pdf PDF
N6247022R0002 Amend 0007.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_16JUN2022.pdf PDF
N6247022R0002 Amend 0007.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_14JUN2022.pdf PDF
N6247022R0002 Amend 0006.pdf PDF
Attachment Q - Anti-Mafia Self-Certification Form for Contracts between 150000 and 5382000.pdf PDF
Attachment R - Anti-Mafia Self-Certification Form for Contracts greater than 5382000.pdf PDF
N6247022R0002 Amend 0005.pdf PDF
Attachment J - PSC Italian Revised Revised March 18 2022.pdf PDF
Attachment O - 1656273Amend0004 Revised Drawings .pdf PDF
N6247022R0002 Amend 0004.pdf PDF
Attachment P - Site Visit Attendance Log.pdf PDF
Attachment O - 1656273Amend0004 Revised Drawings.pdf PDF
Attachment J - PSC Italian Revised Revised March 24 2022.pdf PDF
Attachment N - 1656273Amend0004 Revised Specs.pdf PDF
Attachment E - Schedule B Price Proposal Form Revised March 24 2022.pdf PDF
N6247022R0002 Amend 0003.pdf PDF
ATTACHMENT M - 1656273Amend0003 Revised Drawings.pdf PDF
ATTACHMENT L - 1656273Amend0003 Revised Specs.pdf PDF
N6247022R0002 Amend 0002.pdf PDF
N6247022R0002 Amend 0001.pdf PDF
N6247022R0002.pdf PDF
Attachment H - 1656273dwg27of29.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment H - 1656273dwg14of29.pdf PDF
Attachment H - 1656273dwg19of29.pdf PDF
Attachment H - 1656273dwg12of29.pdf PDF
Attachment H - 1656273dwg25of29.pdf PDF
Attachment H - 1656273dwg08of29.pdf PDF
Attachment H - 1656273dwg04of29.pdf PDF
Attachment H - 1656273dwg16of29.pdf PDF
Attachment K - DWG Index.pdf PDF
Attachment H - 1656273dwg28of29.pdf PDF
Attachment H - 1656273dwg18of29.pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment H - 1656273dwg17of29.pdf PDF
Attachment I - UXO Report.pdf PDF
Attachment H - 1656273dwg26of29.pdf PDF
Attachment H - 1656273dwg29of29.pdf PDF
Attachment H - 1656273dwg07of29.pdf PDF
Attachment C - Construction Experience Project Data Sheet.pdf PDF
Attachment H - 1656273dwg15of29.pdf PDF
Attachment H - 1656273dwg23of29.pdf PDF
Attachment E - Schedule B Price Proposal Form.pdf PDF
Attachment H - 1656273dwg20of29.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
Attachment H - 1656273dwg13of29.pdf PDF
Attachment H - 1656273dwg06of29.pdf PDF
Attachment G - Specifications.pdf PDF
Show 40 more

Latest 50 of 61 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C O

M M

CO

M

M

CO

M

M

CO

M

M

CO

M

M

CO

M

M

COMM

CO

M M

C O

M M

C O

M M

C O

M M

C O

M M

COMM COMM COMM COMM

CO

M

M C

O M

M C

O M

M C

O M

M

COMM

COMM

TV

HH

MH-31A

HH

HH

HH

HH

HH

HH

HH

COMM

COMM

COMM

C O

M M

COMM

CO

M

M

CO

M M

CO

M

M

COMM

COMM

COMM

COMM

CO

MM

COMM

COMM

COMM

COMM

COMM

COMM

COMM

CO

M

M

CO

M

M

C O

M M

C O

M M

COMM

C O

M M

COMM

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

C O

M M

MH-31

MH-32

COMM COMM COMM COMM COMM

COMM

COMM

C O

M M

C O

M M

C O

M M

SAN

SA

N

SAN

SAN

SAN

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SA

N

G G

G G

G G

G G

G G

G G

G G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G G

G G

G G

G G

G

G

G G

G G

G

G

G

G

G

G

G G

G G

G

G

G

G

G

G

G

G

G G

G G

1+

1+

1+

1+

1+280

1+300

1+320

1+340

1+360

1+

1+

1+

1+

1+

0 P

E8

0 P

E8

100 PE80

100 PE80

0 P

E8

G

G

G

G

G

G G

G

G

G G

G G

G

G

G

G

G

FF

F

F

F F

F F

F F

F F

F F

F F

F F

F F

F F

F F

F F

F F

F

F

F

F

F

F

F

F

F

F

F

F F

F

F F

F F

F F F

F F F F F

F F F F

F F F F

F

F F F F

F F

F F F F

F F F F F F F F

F

F F

F

F F

F F

F F

F

FUSL

USL

U

SL

USL

USL

USL

U

SL

U

SL

U

SL

U

SL

US

L

USL USL USL USL

U

SL

U

SL

U

SL

U

SL

USL

USL

USL

U

SL

USL

USL

USL

USL

USL

USLUSLUSLUSL

U

SL

U

SL

U

SL

U

SL

U

SL

USL

USL

USL

USL

USL

USL

USL

U

SL

U

SL

U

SL

US

L

US

L

US

L

U

SL

USL

U

SL

U

SL

U

SL

U

SL

U

SL

USL

USL

US

L

US

L

US

L

US

L

US

L

USL

USL

USLUSLUSL

U

SL

U

SL

VS3S3-SP-1

USL

USL

USL

USL

U

SL

U

SL

U

SL

U

SL

SUBSTATIONVS3-S3

SUBSTATIONVS3-S3PRV

W

W W

W

W

W

W W

X

X X

X X

X X

X X

X X

X X

X

XXXXXXXXX

X

X X

X X

X X

X X

X X

X X

X X

X

X X X

X X

X X

X

X

X

XXX

XXX

XX

X X

X

X

X X

X X

X

X

X

X

X

X

X

X

X

X

X

X X

X X

X X

X X

X X X

XXX

X X X

XXXX

X

X X

X

X X

X

X

XXX

X

X

X X

X

X X

X

X

X

X

X

X X

X X

X

X X X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X X

X X

X X

3 AH

3 AG

2 AH

2 AG

1 CT

3 AH

1 FO

1 CT

3 CB

4 CA

1 QR

2 CL

9 CS

2 FO

1 MG

3 MG

2 CB

3 MS

1 CL

2 AC

1 FO

1 CC

1 CC

1 MG

1 MG

1 CC

3 CR

1 MS

1 MG

6 CC

1 CR

4 CC

5 CS

1 FO

2 QR

2 MG

PIANTUMAZIONELP501

ALBERI, TIPICO

B1 TREE PLANTING, TYPICAL /

PIANTUMAZIONELP501

ARBUSTI, TIPICO

A4 SHRUB PLANTING, TYPICAL /

PLANTING, TYPICAL /LP502

RITOMBAMENTO, TIPICO

A4 GROUNDCOVER

32 lu / 20 lr

98 lu / 60 lr

30 lu / 20 lr 5 lu / 3 lr 85 lu / 65 lr

130 lm/ 130 la

40 lm / 40 la

70 lm / 70 la

8 lm / 8 la

70 lm / 70 la

8 lm / 8 la

135 lm / 135 la

120 lm / 120 la 4 hc

3 mc

3 mc

3 mc

24 lm / 48 aa45 pm /

70 aa

45 pm / 70 aa

30 lm / 60 am

24 lm / 48 aa

115 pm / 65 lm

50 lr / 50 al

60 lr / 60 al

170 lr / 100 al

20 lr / 10 al

80 lr / 45 al

24 lm / 48 aa

3 mc

3 mc

6 mc

3 mc

3 mc

3 mc

3 mc

6 mc

8 mc

550 aa

90 aa

470 aa aa

200 aa

3 vo

120 pm / 40 aa

7 hc

6 mc

4 mc

40 pm / 25 aa

6 mc

1 CC

TYPICAL/ PIANTUMAZIONE DI LP501

ALERBI MULTI-FUSTO, TIPICO

B3MULTI-STEM TREE PLANTING,

PLAN

NORTH

MATCHLINE - SEE SHEET LP104 FOR CONTINUATION / LINEA DI UNIONE - VEDERE TAVOLA LP104 PER CONTINUARE

MATCHLINE - SEE SHEET LP102 FOR CONTINUATION / LINEA DI UNIONE - VEDERE TAVOLA LP102 PER CONTINUARE

LP103

LA

ND

SC

AP

E

PL

AN

TI

NG

P

LA

N

PI

AN

TA

D

I P

IA

NT

UM

AZ

IO

NE

P

AE

SA

GG

IO

La st s av ed b y:

J

EN

N

IF

ER

.R

EN

1(

-1

1-

L as t P lo tte d:

1-

-0

Fi le na m e:

N

A.

AE

C O

M N

ET

.C

O M

\L

FS

\A M

ER

\R

O

AN

O

KE

-U

SR

N K1

\D C

S\

PR

O

JE

C

TS

\B D

L\

\9

_C

AD

_G

IS

\9

_C

AD

\2

0-

SH

EE

TS

\L \1

-V

C 3_

LP

1-

LP

5.

D W

G La st s av ed b y:

J

EN

N

IF

ER

.R

EN

1(

-1 1-

L as t P lo tte d:

1-

-0

Fi le na m e:

N A.

AE

C

O M

N

ET

.C O

M \L

FS

\A

M

ER

\R O

AN

O

KE

-U

SR

N

K1 \D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\L

\1

-V C

3_

LP

1-

LP

5.

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

P-

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

DRAWFORM REVISION: 20 AUGUST 2020

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

5m 10m0 25m 1:250

UNLESS OTHERWISE NOTED, LINEAR DIMENSIONS SHOWN ARE IN METERS.

SE NON ALTRIMENTI INDICATO, LE DIMENSIONI LINEARI SONO IN METRI

KEY PLAN

NO SCALEPIANO STRATEGICO

AS NOTED

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

LP103

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO:

EXISTING TREE TO REMAIN /

ALBERO ESISTENTE CHE DEVE RIMANERE

CANOPY TREE /

ALBERO AD OMBRELLO

EVERGREEN TREE /

ALBERO SEMPREVERDE

SMALL CANOPY TREE, ORNAMENTAL TREE /

ALBERO ORNAMENTALE

SHRUB /

CESPUGLIO

PERENNIALS AND GROUNDCOVER /

PIANTE PERENNI E TAPPEZZAMENTI

SEEDED LAWN /

PRATO SEMINATO

SODDED LAWN /

PRATO RIZOLLATO

SODDED GRASS PAVER /

PAVIMENTAZIONE CON ERBA SEMINATA

PLANTING LEGEND: /

LEGENDA PIANTUMAZIONE:

1. KEEP PLANTS A MINIMUM OF 0.5 METERS FROM APARTMENT

BUILDINGS. /

TENERSE LE PIANTE MINIMO A 0.5m DAGLI APPARTAMENTI.

2. SEE SHEET C-001 FOR CIVIL NOTES AND LEGENDS. /

VEDERE TAVOLA C-001 PER NOTE CIVILI LA LEGENDA.

3. SEE CIVIL SHEETS FOR ADDITIONAL INFORMATION. /

VEDERE LE TAVOLE CIVILI, PER INFORMAZIONI AGGIUNTIVE.

4. SEE SHEET LP501 FOR TREE SUPPORT SCHEDULE AND LP502

FOR PLANT SPACING DETAIL. /

VEDERE TAVOLA LP501 PER L'ABACO DEL SUPPORTO AGLI

ALBERI E LP502 PER DETAGLI DI SPAZIATURA TRA LE PIANTE.

5. SEE SHEET LP601-LP602 FOR PLANTING SCHEDULE AND

PLANTING NOTES. /

VEDERE TAVOLA LP601-LP602 PER PROGRAMMA

PIANTUMAZIONE OPERE PAESAGGISTICHE ET NOTE

PIANTUMAZIONE.

6. SEED ALL AREAS DISTURBED BY CONSTRUCTION UNLESS

OTHERWISE NOTED. /

SEMINARE TUTTE LE AREE ALTERATE DALLA COSTRUZIONE

SALVO DIVERSAMENTE INDICATO

TV

TV

TV

TV

TV

TV

TV

TV

PLAN

NORTH

MATCHLINE - SEE SHEET LP103 FOR CONTINUATION / LINEA DI UNIONE - VEDERE TAVOLA LP103 PER CONTINUARE

MATCHLINE - SEE SHEET LP105 FOR CONTINUATION / LINEA DI UNIONE - VEDERE TAVOLA LP105 PER CONTINUARE

LP104

La st s av ed b y:

J

EN

N

IF

ER

.R

EN

1(

-1

1-

L as t P lo tte d:

1-

-0

Fi le na m e:

N

A.

AE

C O

M N

ET

.C

O M

\L

FS

\A M

ER

\R

O

AN

O

KE

-U

SR

N K1

\D C

S\

PR

O

JE

C

TS

\B D

L\

\9

_C

AD

_G

IS

\9

_C

AD

\2

0-

SH

EE

TS

\L \1

-V

C 3_

LP

1-

LP

5.

D W

G La st s av ed b y:

J

EN

N

IF

ER

.R

EN

1(

-1 1-

L as t P lo tte d:

1-

-0

Fi le na m e:

N A.

AE

C

O M

N

ET

.C O

M \L

FS

\A

M

ER

\R O

AN

O

KE

-U

SR

N

K1 \D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\L

\1

-V C

3_

LP

1-

LP

5.

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

DRAWFORM REVISION: 20 AUGUST 2020

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

5m 10m0 25m 1:250

UNLESS OTHERWISE NOTED, LINEAR DIMENSIONS SHOWN ARE IN METERS.

SE NON ALTRIMENTI INDICATO, LE DIMENSIONI LINEARI SONO IN METRI

KEY PLAN

NO SCALEPIANO STRATEGICO

AS NOTED

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

LP104

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO:

EXISTING TREE TO REMAIN /

ALBERO ESISTENTE CHE DEVE RIMANERE

CANOPY TREE /

ALBERO AD OMBRELLO

EVERGREEN TREE /

ALBERO SEMPREVERDE

SMALL CANOPY TREE, ORNAMENTAL TREE /

ALBERO ORNAMENTALE

SHRUB /

CESPUGLIO

PERENNIALS AND GROUNDCOVER /

PIANTE PERENNI E TAPPEZZAMENTI

SEEDED LAWN /

PRATO SEMINATO

SODDED LAWN /

PRATO RIZOLLATO

SODDED GRASS PAVER /

PAVIMENTAZIONE CON ERBA SEMINATA

PLANTING LEGEND: /

LEGENDA PIANTUMAZIONE:

LA

ND

SC

AP

E

PL

AN

TI

NG

P

LA

N

PI

AN

TA

D

I P

IA

NT

UM

AZ

IO

NE

P

AE

SA

GG

IO

1. KEEP PLANTS A MINIMUM OF 0.5 METERS FROM APARTMENT

BUILDINGS. /

TENERSE LE PIANTE MINIMO A 0.5m DAGLI APPARTAMENTI.

2. SEE SHEET C-001 FOR CIVIL NOTES AND LEGENDS. /

VEDERE TAVOLA C-001 PER NOTE CIVILI LA LEGENDA.

3. SEE CIVIL SHEETS FOR ADDITIONAL INFORMATION. /

VEDERE LE TAVOLE CIVILI, PER INFORMAZIONI AGGIUNTIVE.

4. SEE SHEET LP501 FOR TREE SUPPORT SCHEDULE AND LP502

FOR PLANT SPACING DETAIL. /

VEDERE TAVOLA LP501 PER L'ABACO DEL SUPPORTO AGLI

ALBERI E LP502 PER DETAGLI DI SPAZIATURA TRA LE PIANTE.

5. SEE SHEET LP601-LP602 FOR PLANTING SCHEDULE AND

PLANTING NOTES. /

VEDERE TAVOLA LP601-LP602 PER PROGRAMMA

PIANTUMAZIONE OPERE PAESAGGISTICHE ET NOTE

PIANTUMAZIONE.

6. SEED ALL AREAS DISTURBED BY CONSTRUCTION UNLESS

OTHERWISE NOTED. /

COMM COMM COMM COMM COMM COMM

MH-24A

SANSAN

MG

MG

1+220

1+232

150 PE80

PLAN

NORTH

MATCHLINE - SEE SHEET LP104 FOR CONTINUATION / LINEA DI UNIONE - VEDERE TAVOLA LP104 PER CONTINUARE

MA

TC

HL

IN

E

- S

EE

S

HE

ET

LP

2 F

OR

C

ON

TI

NU

AT

IO

N / L

IN

EA

D I U

NI

ON

E

- V

ED

ER

E

TA

VO

LA

LP

2 P

ER

C

ON

TI

NU

AR

E

LP105

La st s av ed b y:

J

EN

N

IF

ER

.R

EN

1(

-1

1-

L as t P lo tte d:

1-

-0

Fi le na m e:

N

A.

AE

C O

M N

ET

.C

O M

\L

FS

\A M

ER

\R

O

AN

O

KE

-U

SR

N K1

\D C

S\

PR

O

JE

C

TS

\B D

L\

\9

_C

AD

_G

IS

\9

_C

AD

\2

0-

SH

EE

TS

\L \1

-V

C 3_

LP

1-

LP

5.

D W

G La st s av ed b y:

J

EN

N

IF

ER

.R

EN

1(

-1 1-

L as t P lo tte d:

1-

-0

Fi le na m e:

N A.

AE

C

O M

N

ET

.C O

M \L

FS

\A

M

ER

\R O

AN

O

KE

-U

SR

N

K1 \D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\L

\1

-V C

3_

LP

1-

LP

5.

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

DRAWFORM REVISION: 20 AUGUST 2020

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

5m 10m0 25m 1:250

UNLESS OTHERWISE NOTED, LINEAR DIMENSIONS SHOWN ARE IN METERS.

SE NON ALTRIMENTI INDICATO, LE DIMENSIONI LINEARI SONO IN METRI

KEY PLAN

NO SCALEPIANO STRATEGICO

AS NOTED

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

LP105

LP105

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO:

EXISTING TREE TO REMAIN /

ALBERO ESISTENTE CHE DEVE RIMANERE

CANOPY TREE /

ALBERO AD OMBRELLO

EVERGREEN TREE /

ALBERO SEMPREVERDE

SMALL CANOPY TREE, ORNAMENTAL TREE /

ALBERO ORNAMENTALE

SHRUB /

CESPUGLIO

PERENNIALS AND GROUNDCOVER /

PIANTE PERENNI E TAPPEZZAMENTI

SEEDED LAWN /

PRATO SEMINATO

SODDED LAWN /

PRATO RIZOLLATO

SODDED GRASS PAVER /

PAVIMENTAZIONE CON ERBA SEMINATA

PLANTING LEGEND: /

LEGENDA PIANTUMAZIONE:

LA

ND

SC

AP

E

PL

AN

TI

NG

P

LA

N

PI

AN

TA

D

I P

IA

NT

UM

AZ

IO

NE

P

AE

SA

GG

IO

1. KEEP PLANTS A MINIMUM OF 0.5 METERS FROM APARTMENT

BUILDINGS. /

TENERSE LE PIANTE MINIMO A 0.5m DAGLI APPARTAMENTI.

2. SEE SHEET C-001 FOR CIVIL NOTES AND LEGENDS. /

VEDERE TAVOLA C-001 PER NOTE CIVILI LA LEGENDA.

3. SEE CIVIL SHEETS FOR ADDITIONAL INFORMATION. /

VEDERE LE TAVOLE CIVILI, PER INFORMAZIONI AGGIUNTIVE.

4. SEE SHEET LP501 FOR TREE SUPPORT SCHEDULE AND LP502

FOR PLANT SPACING DETAIL. /

VEDERE TAVOLA LP501 PER L'ABACO DEL SUPPORTO AGLI

ALBERI E LP502 PER DETAGLI DI SPAZIATURA TRA LE PIANTE.

5. SEE SHEET LP601-LP602 FOR PLANTING SCHEDULE AND

PLANTING NOTES. /

VEDERE TAVOLA LP601-LP602 PER PROGRAMMA

PIANTUMAZIONE OPERE PAESAGGISTICHE ET NOTE

PIANTUMAZIONE.

6. SEED ALL AREAS DISTURBED BY CONSTRUCTION UNLESS

OTHERWISE NOTED. /

L a s t s a v e d b y

Z

H I H

A O

L I s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S L V

C L P

L P

D

W G

L a s t s a v e d b y

Z

H I H

A O

L I s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S L V

C L P

L P

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

DRAWFORM REVISION: 20 AUGUST 2020

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

AS NOTED

LP501

L A

N D

S C

A P

E

P

L A

N T

I N

G

D

E T

A I L S

D E

T T

A G

L I

P

I A

N T

U M

A Z

I O

N E

P

A E

S A

G G

I O

UNLESS OTHERWISE NOTED, LINEAR DIMENSIONS SHOWN ARE IN MILLIMETERS. /

SE NON ALTRIMENTI INDICATO, LE DIMENSIONI LINEARI SONO IN MILLIMETRI.

B1

A1 A3 A4

B3

TREE PLANTING, GUYING - PIANTUMAZIONE

PLAN / PIANTA

M

I

N

FINISH GRADE /

PIANO FINITO

PLANTING SOIL MIX /

MIX TERRENO VEGETALE

SCARIFY EXCAVATION /

SCARIFICA

32.41

75MM OR LARGER CALIPER TREE /

CALIBRO PER ALBERO 75 MM O

PIÙ GRANDE

32.47

32.49

32.40

32.48

32.42

32.43

32.44

32.45

32.46

32.52

B2

LP101 SCALE:

DI ALBERI, STABILIZZAZIONE DEGLI ALBERI

NOT TO SCALE / NON IN SCALA

32.50

2400-3600mm

TREE HEIGHT /

ALTEZZA

ALBERO

TREE CALIPER /

CALIBRO ALBERO

SUPPORT

SYSTEM /

SISTEMA DI

SUPPORTO

WEBBED TIE

OR CABLE /

FASCETTA O CAVO

TURNBUCKLE /

TENDITORE

HOSE /

TUBO

QUAN-

TITY/

QUAN-

TITÀ

2100mm

UPRIGHT

STAKE /

PALO

VERTICALE

WOVEN

POLYPROPYLENE TIE /

CAVI IN

POLIPROPILENE

INTRECCIATO

--LESS THAN

75mm /

MENO DI

GUY /

TIRANTE

75mm AND UP /

E SU

6000mm

AND OVER /

E SOPRA

DEADMAN /

SISTEMA DI

ANCORAGGIO

DEADMAN

150mm AND UP /

E SU

100mm AND UP /

E SU

3*

4.8mm CABLE* /

CAVO 4.8MM

9.5mm X 150mm*

* OR AS APPROPRIATE / O COME APPROPRIATO

19mm

3600-4200mm

4200-6000mm

WOVEN

POLYPROPYLENE TIE /

CAVI IN

POLIPROPILENE

INTRECCIATO

WOVEN

POLYPROPYLENE TIE /

CAVI IN

POLIPROPILENE

INTRECCIATO

TREE SUPPORT SCHEDULE -

-- --GUY /

TIRANTE

D5

LP101 SCALE:

PIANO DI SUPPORTO DELL'ALBERO

NOT TO SCALE / NON IN SCALA

FINISH GRADE /

PIANO FINITO

PLANTING SOIL MIX /

MIX TERRENO VEGETALE

PLAN / PIANTA

SCARIFY EXCAVATION /

SCARIFICA

MULTI-STEM TREE PLANTING -

32.41

M

N

32.42

32.43

32.44

32.45

32.46

32.47

32.49

32.48

32.40

32.52

A1

LP101 SCALE:

PIANTUMAZIONE DI ALBERI MULTI-FUSTO

NOT TO SCALE / NON IN SCALA

32.50

SHRUB PLANTING -

PLANTING SOIL MIX AND PLANTING BED

CONTINUOUS BETWEEN PLANTS /

TERRENO MISTO DI TERRA VEGETALE E LETTO

DI PIANTAGIONE CONTINUO TRA PIANTE

75MM MULCH, FORM INTO SAUCER AROUND EACH PLANT /

75MM PACCIAME, CREARE UN DISCO ATTORNO AD OGNI PIANTA

SCARIFY EXCAVATION / SCARIFICA

FINISH GRADE / PIANO FINITO

C1

LP101 SCALE:

PIANTUMAZIONE ARBUSTI

NOT TO SCALE / NON IN SCALA

SHEET KEYNOTES: /

NOTE CHIAVE DI QUESTO FOGLIO:

32.40 1/8 DEPTH ROOT BALL MAXIUMUM. /

MASSIMO 1/8 DI PROFONDITÀ DEL BULBO RADICALE.

32.41 3X ROOT BALL WIDTH. /

3X LARGHEZZA DEL BULBO RADICALE.

32.42 TREE SUPPORT SYSTEM (3) GUYING STAKES WITH WIDE SOFT WOVEN POLYPROPYLENE TIES. USE

SECURED SLIPKNOT TO FORM LOOP 150-200MM Ø LARGER THAN TRUNK. SECURE TREE BUT ALLOW FOR

SLIGHT MOVEMENT. /

SISTEMA DI SOSTEGNO DELL'ALBERO (3) PALI DI TIRAGGIO CON LARGHE FASCETTE IN POLIPROPILENE MORBIDO INTRECCIATO. UTILIZZARE CAPPI SICURI PER FORMARE UN'ANSA DI 150-200 MM Ø PIÙ GRANDE DEL TRONCO. FISSARE L'ALBERO IN MODO SICURO MA CONSENTIRE UN LEGGERO MOVIMENTO.

32.43 SET TRUNK FLARE ABOVE SURROUNDING FINISH GRADE. DO NOT COVER WITH SOIL. /

IMPOSTARE IL CEPPO AL DI SOPRA DEL LIVELLO DI RIFINITURA CIRCOSTANTE. NON COPRIRE CON

TERRENO.

32.44 75MM MULCH, DO NOT COVER TRUNK FLARE. /

75MM PACCIAME, NON COPRIRE IL PIEDE DEL TRONCO.

32.45 AFTER POSITIONING TREE, PARTIALLY BACKFILL TO SUPPORT ROOT BALL SHAPE AND REMOVE ALL TREATED OR SYNTHETIC BURLAP, WIRE BASKET, ROPE, TWINE, AND TOP THIRD OF NATURAL BURLAP

FROM FIRM ROOT BALL. /

DOPO AVER POSIZIONATO L'ALBERO, RIEMPIRE PARZIALMENTE IL TERRENO PER SOSTENERE LA FORMA DELLA ZOLLA DI RADICE E RIMUOVERE TUTTA LA IUTA TRATTATA O SINTETICA, IL CESTINO DI FILO, LA CORDA, LO SPAGO E IL TERZO SUPERIORE DELLA IUTA NATURALE DALLA PALLA DI RADICE SOLIDA.

32.46 PROVIDE 75-100MM HEIGHT SAUCER BEYOND EDGE OF ROOT BALL. /

FORNIRE PIATTINO DI ALTEZZA 75-100MM OLTRE IL BORDO DELLA ZOLLA DELLA RADICE.

32.47 SURVEYOR'S FLAG, AS NECESSARY. /

BANDIERINA DI SEGNALAZIONE, SE NECESSARIO.

32.48 NOTE: FLAGGING IS ENCOURAGED NEAR PEDESTRIAN AREAS, PAVED OR UNPAVED. OBTAIN

CONTRACTING OFFICER’S APPROVAL FOR FLAGGING LOCATIONS. /

NOTA: È INCORAGGIATA LA SEGNALAZIONE IN PROSSIMITÀ DI AREE PEDONALI, PAVIMENTATE O NON PAVIMENTATE. OTTENERE L'APPROVAZIONE DI RESPONSABILE DELLA UFFICIO CONTRAENTE' PER LE AREE

DI SEGNALAZIONE.

32.49 STAKE IN UNDISTURBED SOIL. /

INFIGGERE IN TERRENO INDISTURBATO, 200 MM MINIMO OLTRE LO SCAVO.

32.50 INSTALL ROOT BARRIER AT TREES PER DETAIL A4 ON SHEET LS504. /

INSTALLARE LE BARRIERE PER LE RADICI IN PROSSIMITÁ DEGLI ALBERI COME DETTAGLIATO NELLA

TAVOLA LS504

32.52 TRIM ALL TREE BRANCHES THAT FALL WITHIN PLAY EQUIPMENT USE ZONES TO BE AT LEAST 84 INCHES (2130MM) ABOVE THE UNDERLYING DESIGNATED PLAY SURFACE AND THE PIVOT POINT OF A SWING. / TAGLIARE TUTTI I RAMI DEGLI ALBERI CHE CADONO ALL'INTERNO DELLE ZONE DI UTILIZZO DELLE ATTREZZATURE DI GIOCO PER ESSERE ALMENO 84 POLLICI (2130 MM) SOPRA LA SUPERFICIE DI GIOCO

SOTTOSTANTE DESIGNATA E IL PUNTO DI ROTAZIONE DI UN'ALTALENA.

EVERGREEN TREE PLANTING -

TAMP SOIL AROUND ROOT

BALL TO STABILIZE TREE /

TERRICCIO ATTORNO AL

BULBO RADICALE PER

STABILIZZARE L'ALBERO

FINISH GRADE /

PIANO FINITO

PLANTING SOIL MIX /

MIX TERRENO VEGETALE

SCARIFY EXCAVATION /

SCARIFICA

32.41

32.43

32.44

32.45

32.46

32.40

LP101 SCALE:

PIANTUMAZIONE ALBERI SEMPREVERDI

NOT TO SCALE / NON IN SCALA

32.52

32.50 s t s a v e d b y

Z

H I H

A O

L I s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S L V

C L P

L P

D

W G

L a s t s a v e d b y

Z

H I H

A O

L I s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S L V

C L P

L P

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

DRAWFORM REVISION: 20 AUGUST 2020

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

AS NOTED

LP502

UNLESS OTHERWISE NOTED, LINEAR DIMENSIONS SHOWN ARE IN MILLIMETERS. /

SE NON ALTRIMENTI INDICATO, LE DIMENSIONI LINEARI SONO IN MILLIMETRI.

A4

C4

L A

N D

S C

A P

E

P

L A

N T

I N

G

D

E T

A I L S

D E

T T

A G

L I

P

I A

N T

U M

A Z

I O

E

S A

G G

I O

600mm O.C.

900mm O.C. 650mm O.C.

400mm O.C.

ROW "A" /

RIGA 'A

PLANT SPACING "D" /

SPAZIATURA IMPIANTO 'D'

300mm O.C. 250mm O.C.

PLANT, TYPICAL /

PIANTA, TIPICO

D

"D"

D

A

NOTES / NOTA:

1. INSTALL PLANTS WITH

TRIANGULAR SPACING

UNLESS OTHERWISE NOTED /

INSTALLRE LE PIANTE CON

SPAZIATURA TRIANGOLARE A

MENO DI ALTRE NOTE SUI

DISEGNI

2. O.C. = ON CENTER /

O.C. = AL CENTRO

325mm O.C.

400mm O.C.

375mm O.C.

450mm O.C.

250mm O.C.

200mm O.C.

150mm O.C.

175mm O.C.

225mm O.C.

125mm O.C.

PLANT SPACING -

D5

LP101 SCALE:

DISTANZA TRA LE PIANTE

NOT TO SCALE / NON IN SCALA

SET PLANTS IN STAGGERED ROWS AT

SPECIFIED SPACING UNLESS

OTHERWISE INDICATED ON DRAWINGS /

INSTALALRE LE PIANTE IN FILE SFALSATE

A DISTANZE DEFINITE A MENO DI ALTRE

INDICAZIONI SUI DISEGNI

75MM MULCH OVER ENTIRE BED. DO NOT

COVER CROWNS OF PLANTS /

75MM PACCIAME SOPRA L'INTERO LETTO.

NON COPRIRE LE CORONE DELLE PIANTE

PLANTING SOIL MIX AND PLANTING BED

CONTINUOUS BETWEEN PLANTS /

TERRENO MISTO CONTINUO TRA PIANTE

SCARIFY EXCAVATION /

SCARIFICAZIONE

M

I N

C1

LP101 SCALE:

RITOMBAMENTO

NOT TO SCALE / NON IN SCALA

GROUNDCOVER PLANTING -

s t s a v e d b y

M

U E

L L E

R K s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S L V

C L P

L P

D

W G

L a s t s a v e d b y

M

U E

L L E

R K s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S L V

C L P

L P

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

DRAWFORM REVISION: 20 AUGUST 2020

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

AS NOTED

LP601

L A

N D

S C

A P

E

P

L A

N T

I N

G

S

C H

E D

U L E

T A

B E

L

A

N T

U M

A Z

I O

E

S A

G G

I O

PLANTING SCHEDULE: /

TABELLA PIANTUMAZIONE:

TREE REPLACEMENT SCHEDULE: /

TABELLA SOSTITUZIONE ALBERO:

SUMMARY OF REQUIREMENTS FOR TREE REPLACEMENT STANDARDS / RIEPILOGO DEI REQUISITI DELLE NORME PER LA SOSTITUZIONE ALBERO:

TREES TO BE REMOVED ≤ 10 CM DBH: 0 / ALBERO DA RIMUOVERE ≤ 10 CM DIAMETRO: 0

REPLACEMENT TREES REQUIRED: 0 / SOSTITUZIONE ALBERI RICHIESTA: 0

REPLACEMENT TREES PROVIDED: 96 (5CM DIAMETER TREES) / SOSTITUZIONE ALBERI PREVISTA: 96 (5CM DIAMETRO TREES)

TREES TO BE REMOVED = 11-20 CM DBH: 5 / ALBERI DA RIMUOVERE = 11-20 CM DIAMETRO: 5

REPLACEMENT TREES REQUIRED: 5 / SOSTITUZIONE ALBERI RICHIESTA: 5

REPLACEMENT TREES PROVIDED: 6 (10-12CM DIAMETER TREES) / SOSTITUZIONE ALBERI PREVISTA: 6 (10-12CM DIAMETRO TREES)

TREES TO BE REMOVED = 21-30 CM DBH: 26 / ALBERI DA RIMUOVERE = 21-30 CM DIAMETRO: 26

REPLACEMENT TREES REQUIRED: 26 / SOSTITUZIONE ALBERI RICHIESTA: 26

REPLACEMENT TREES PROVIDED: 26 (14-16CM DIAMETER TREES) / SOSTITUZIONE ALBERI PREVISTA: 26 (14-16CM DIAMETRO TREES)

TREES TO BE REMOVED ≥31 CM DBH: 91 / ALBERI DA RIMUOVERE ≥31 CM DIAMETRO: 91

REPLACEMENT TREES REQUIRED: 91 / SOSTITUZIONE ALBERI RICHIESTA: 91

REPLACEMENT TREES PROVIDED: 91 (20-22CM DIAMETER TREES) / SOSTITUZIONE ALBERI PREVISTA: 91 (20-22CM DIAMETRO TREES)

CALCULATION OF THE REQUIRED REPLACEMENT TREES / CALCOLO DELA RICHIESTA DI SOSTITUZIONE ALBERI:

1. DBH = TREE DIAMETER TO BE MEASURED AT A 1.3M HEIGHT FROM THE GROUND. /

DBH = DIAMETRO DELL'ALBERO MISURATO A 1.3M DI ALTEZZA DAL TERRENO.

2. PER THE MUNICIPALITY OF VICENZA BUILDING REGULATIONS, ANY TREE THAT IS REMOVED DURING CONSTRUCTION IS REQUIRED TO BE REPLACED BY A NEW TREE

WITH A TRUNK SIZE NO LESS THAN HALF OF THE TREE BEING REPLACED OR ALTERNATIVELY WITH A TREE NO LESS THAN 20 CM DIAMETER IN TRUNK SIZE. /

SECONDO IL REGOLAMENTO EDILIZIO DEL COMUNE DI VICENZA, QUALSIASI ALBERO TAGLIATO IN COSTRUZIONE DEVE ESSERE SOSTITUITO DA UN ALBERO NUOVO CON

TRONCO DI DIMENSIONI NON INFERIORI ALLA METÀ

DELL'ALBERO

DA SOSTITUIRE O IN ALTERNATIVA CON UN ALBERO CON TRONCO DI DIAMETRO NON MINORE DI 20 CM.

s t s a v e d b y

J E

N N

I F

E R

R

E N s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S L V

C L P

L P

D

W G

L a s t s a v e d b y

J E

N N

I F

E R

R

E N s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L C

A D

G

I S

C

A D

S

H E

E T

S L V

C L P

L P

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

DRAWFORM REVISION: 20 AUGUST 2020

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

AS NOTED

LP602

L A

N D

S C

A P

E

P

L A

N T

I N

G

N

O T

E S

N O

T

A

N T

U M

A Z

I O

E

S A

G G

I O

PLANTING NOTES: /

NOTE PIANTUMAZIONE:

1. PLANT MATERIAL SHALL BE FURNISHED AND INSTALLED AS INDICATED, INCLUDING ALL LABOR, MATERIALS, PLANTS, EQUIPMENT, INCIDENTALS, AND CLEAN-UP. /

IL MATERIALE PER LA PIANTUMAZIONE DOVRA' ESSERE FORNITO ED INSTALLATO COME INDICATO, INCLUSA LA MANODOPERA, MATERIALI, PIANTE, ATTREZZATURE, IMPREVISTI E LA

PULIZIA FINALE.

2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PLANTING AT CORRECT GRADES AND ALIGNMENT. LAYOUT TO BE APPROVED BY CONTRACTING OFFICER PRIOR TO INSTALLATION. /

L'IMPRESA DOVRA' ESSERE RESPONSABILE DELLA PIANTUMAZIONE ALLE QUOTE, ALLINEAMENTI E LIVELLI DI FINITURA CORRETTI CHE DOVRANNO ESSERE APPROVATI

DALL'UFFICIALE CONTRAENTE PRIMA DELL'INSTALLAZIONE.

3. CONTRACTOR SHALL FIELD VERIFY ALL UTILITY LOCATIONS PRIOR TO COMMENCEMENT OF WORK. DO NOT PLANT DIRECTLY OVER UTILITY LINES. CONTRACTOR SHALL BE

RESPONSIBLE FOR DAMAGE RESULTING FROM FAILURE TO PROPERLY LOCATE AND PROTECT UTILITIES. /

L'IMPRESA DOVRA' VERIFICARE IN CAMPO LA POSIZIONE DI TUTTI I SERVIZI INTERRATI PRIMA DELL'INIZIO DEI LAVORI. NON PIANTARE DIRETTAMENTE SOPRA I SERVIZI INTERRATI;

L'IMPRESA SARA' RESPONSABILE PER DANNI DERIVANTI DALLA NON PROTEZIONE DELLE LINEE SERVIZI INTERRATI.

4. THE PLANT QUANTITIES SHOWN ARE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL QUANTITIES AND REPORTING ANY

DISCREPANCIES TO THE CONTRACTING OFFICER FOR CLARIFICATION PRIOR TO THE CONTRACT AWARD AND COMMENCEMENT OF WORK. /

LE QUANTITA' DELLE PIANTE INDICATE SONO A FAVORE DELL'IMPRESA. L'IMPRESA DEVE VERIFICARE LE QUANTITA' E DEVE RIPORTARE OGNI DISCREPANZA ALL'UFFICIALE

CONTRAENTE E CHIEDERE CHIARIMENTI PRIMA DELL'AGGIUDICAZIONE E DI INIZIARE I LAVORI.

5. PRIOR TO PLANTING INSTALLATION, THE CONTRACTOR SHALL CONFIRM THE AVAILABILITY OF ALL THE SPECIFIED PLANT MATERIALS. SUBMIT DATED PHOTOGRAPHS WITH SCALE

REFERENCE, OF ALL TREE MATERIALS AND SPECIMEN MATERIAL TO THE CONTRACTING OFFICER FOR APPROVAL PRIOR TO ORDERING. /

PRIMA DELLA PIANTUMAZIONE, L'IMPRESA DOVRA' CONFERMARE LA DISPONIBILITA' DI TUTTI I MATERIALI VEGETALI SPECIFICATI. SOTTOMETTERE ALL'UFFICIALE CONTRAENTE

FOTOGRAFIE DATATE E CON RIFERIMENTO IN SCALA E UN CAMPIONE DI TUTTI I MATERIALI.

6. ALL PLANT MATERIAL SIZES SPECIFIED ARE MINIMUM SIZES. CONTAINER SIZE SHALL BE INCREASED IF NECESSARY TO PROVIDE OVERALL PLANT SIZE SPECIFIED. /

TUTTE LE TAGLIE DEI MATERIALI DELLA PIANTUMAZIONE SONO QUELLE MINIME. LA DIMENSIONE DEI CONTAINER DOVRA' ESSERE AUMENTATA IN MODO DA CONTENERE LA

GRANDEZZA TOTALE DELLA PIANTA.

7. CONTRACTOR SHALL LEAVE NO HOLES OPEN OVERNIGHT. IF PLANTS CANNOT BE PLANTED IN HOLES DUG, THE HOLES SHALL BE BACKFILLED OR SUITABLY COVERED. /

L'IMPRESA NON DOVRA' LASCIARE BUCHE APERTE DURANTE LA NOTTE. SE GLI ALBERI NON POTRANNO ESSERE PIANTATI IN BUCHE SCAVATE, LE BUCHE DOVRANNO ESSERE

RIEMPITI OD OPPORTUNAMENTE COPERTE.

8. PLANTS SHALL BE TYPICAL OF THEIR SPECIES AND VARIETY; HAVE NORMAL GROWTH HABITS, WELL-DEVELOPED DENSELY FOLIATED BRANCHES, AND VIGOROUS ROOT SYSTEMS;

AND BE FREE FROM DEFECTS, INJURIES, WEEDS, AND INSECT PESTS. QUALITY AND SIZE OF PLANTS, SPREAD OF ROOTS, AND SIZE OF ROOTBALL SHALL BE IN ACCORDANCE WITH

THE MOST RECENT VERSION OF ANSI Z60.1 "AMERICAN STANDARD FOR NURSERY STOCK" PUBLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN, INC. /

LE PIANTE DOVRANNO ESSERE TIPICHE NELLE LORO SPECIE E VARIETA'; DOVRANNO AVERE ABITUDINI NORMALI DI CRESCITA, RAMI BEN SVILUPPATI DENSAMENTE FOLIATI E RADICI

VIGOROSE; ED ESSERE ESENTI DA DIFETTI, LESIONI, ERBACCE E INSETTI NOCOVI. QUALITÀ E DIMENSIONI DELLE PIANTE, ESPANSIONE DELLE RADICI E LE DIMENSIONI DELLE ZOLLE

DEVONO ESSERE CONFORMI ALLA VERSIONE PIÙ RECENTE DI ANSI Z60.1 "STANDARD AMERICANO PER STOCK DI VIVAIO" PUBBLICATO DALL'ASSOCIAZIONE AMERICANA DI

NURSERYMEN, INC.

9. ALL PLANT MATERIAL SHALL BE GUARANTEED BY THE CONTRACTOR TO BE IN VIGOROUS GROWING CONDITION. PROVISION SHALL BE MADE FOR A GROWTH GUARANTEE OF AT

LEAST ONE YEAR FROM THE DATE OF ACCEPTANCE FOR TREES AND SHRUBS. REPLACEMENTS SHALL BE MADE AT THE BEGINNING OF THE FIRST FOLLOWING PLANTING SEASON.

ALL REPLACEMENTS SHALL HAVE A GUARANTEE EQUAL TO THAT STATED ABOVE. /

TUTTE LE PIANTE DOVRANNO ESSERE GARANTITE DALL'IMPRESA PER AVERE UNA CONDIZIONE DI CRESCITA VIGOROSA. LA FORNITURA DEVE ESSERE EFFETTUATA PER UNA

GARANZIA DI CRESCITA DI ALMENO UN ANNO DALLA DATA DI ACCETTAZIONE DEGLI ALBERI E DEGLI ARBUSTI. LE SOSTITUZIONI DEVONO ESSERE EFFETTUATE ALL'INIZIO DELLA

PRIMA STAGIONE ADATTA ALLA PIANTUMAZIONE. LE SOSTITUZIONI DEVONO ESSERE EFFETTUATE ALL'INIZIO DELLA PRIMA STAGIONE DI SEMINA.TUTTE LE SOSTITUZIONI DOVRANNO

AVERE UNA GARANZIA PARI A QUESTA SOPRA CITATA.

10. PLANT MATERIAL SHALL BE PLANTED ON THE DAY OF DELIVERY IF/WHEN PRACTICAL. IN THE EVENT THAT THIS IS NOT POSSIBLE, THE CONTRACTOR SHALL PROTECT STOCK NOT

PLANTED. PLANTS SHALL NOT REMAIN UNPLANTED FOR LONGER THAN A THREE-DAY PERIOD AFTER DELIVERY. ANY PLANTS NOT INSTALLED DURING THIS PERIOD SHALL BE

REJECTED. /

IL MATERIALE DELLA PIANTUMAZIONE DEVE ESSERE IMPIANTATO IL GIORNO STESSO DELLA CONSEGNA SE / QUANDO PRATICABILE. NEL CASO IN CUI NON È POSSIBILE, L'APPALTATORE PROTEGGERA' LO STOCK NON IMPIANTATO. LE PIANTE NON DEVONO RIMANERE IMPIANTATE PER UN PERIODO SUPERIORE A TRE GIORNI DOPO LA CONSEGNA. OGNI

PIANTA NON INSTALLATA DURANTE QUESTO PERIODO DEVE ESSERE RESPINTO.

11. ALL PLANTS SHALL BE PLANTED IN AMENDED TOP SOIL THAT IS THOROUGHLY WATERED AND TAMPED AS BACK-FILLING PROGRESSES. LARGE PLANTING AREAS TO INCORPORATE

FERTILIZER AND SOIL CONDITIONERS AS STATED IN PLANTING SPECIFICATIONS. CONTRACTOR SHALL BEAR ALL COSTS OF TESTING OF SOILS, AMENDMENTS, ETC. ASSOCIATED

WITH THE WORK. SEE SPECIFICATIONS FOR ADDITIONAL TESTING REQUIREMENTS. /

TUTTE LE PIANTE DEVONO ESSERE PIANTATE IN UN TERRENO VEGETALE SUPERIORE CONCIMATO CHE È COMPLETAMENTE UMIDIFICATO E COMPATTATO DURANTE IL RIEMPIMENTO.

CI DEVONO ESSERE AMPIE AREE PER LA PIANTUMAZIONE PER INCORPORARE CONCIMI E AMMENDANTI DEL SUOLO IN BASE ALLE SPECIFICHE DI PIANTUMAZIONE. L'APPALTATORE

DOVRA' ACCOLLARSI TUTTI I COSTI DI PROVA DI SUOLI, MODIFICHE, ECC. ASSOCIATO AL LAVORO. VEDI SPECIFICHE PER I REQUISITI DI PROVA AGGIUNTIVI

12. PLANTS SHALL NOT BE BOUND WITH WIRE OR ROPE AT ANY TIME SO AS TO DAMAGE THE BARK OR BREAK BRANCHES. PLANTS SHALL BE HANDLED FROM THE BOTTOM OF THE BALL

ONLY. /

LE PIANTE NON DEVONO ESSERE FISSATE CON CAVO O CORDA IN QUALSIASI MOMENTO, IN MODO DA DANNEGGIARE LA CORTECCIA O ROMPERE I RAMI. LE PIANTE DEVONO ESSERE

MANEGGIATE SOLO DALLE ZOLLE

13. PLANTING OPERATIONS SHALL BE PERFORMED DURING PERIODS WITHIN THE PLANTING SEASON WHEN WEATHER AND SOIL CONDITIONS ARE SUITABLE AND IN ACCORDANCE WITH

ACCEPTED LOCAL PRACTICE. PLANTS SHALL NOT BE INSTALLED IN TOP SOIL THAT IS IN A MUDDY CONDITION. /

LE OPERAZIONI DI PIANTUMAZIONE DEVONO ESSERE EFFETTUATE DURANTE I PERIODI NELL'AMBITO DELLA STAGIONE INDICATA DI PIANTUMAZIONE QUANDO LE CONDIZIONI

METEREOLOGICHE E DEL SUOLO SONO IDONEE E SECONDO LA PRATICA LOCALE ACCETTATA. LE PIANTE NON DEVONO ESSERE INSTALLATE IN TERRENI IN CONDIZIONE FANGOSA

14. NO PLANTS, SHALL BE PLANTED LESS THAN FOURTY SIX CENTIMETERS FROM EXISTING STRUCTURES AND SIDEWALKS. /

NESSUNA PIANTA, DEVE ESSERE IMPIANTO A MENO DI QUARANTASEI CENTIMETRI DA STRUTTURE ESISTENTI E MARCIAPIEDI.

15. ALL PLANTING BEDS SHALL BE MULCHED WITH 75MM LAYER OF DOUBLE SHREDDED HARDWOOD BARK MULCH. /

TUTTI I LETTI DI SEMINA DEVONO ESSERE PACCIAMATI CON UNO STRATO DI 75 MM DI CORTECCIA DI LEGNO DURO DOPPIAMENTE TRITURATO.

16. SET ALL PLANTS PLUMB AND STRAIGHT. SET AT SUCH LEVEL THAT A NORMAL OR NATURAL RELATIONSHIP TO THE GROUND SURFACE WILL BE ESTABLISHED. LOCATE THE PLANT IN

THE CENTER OF THE PIT. CONTRACTOR SHALL BE RESPONSIBLE FOR STABILITY AND PLUMB CONDITION OF ALL TREES AND SHRUBS AND SHALL BE LEGALLY VIABLE FOR ANY

DAMAGE CAUSED BY INSTABILITY OF ANY PLANT MATERIALS. /

IMPOSTARE TUTTE LE PIANTE A PIOMBO E DRITTE. IMPOSTARE AD UN LIVELLO TALE DA STABILIRE UN RAPPORTO NORMALE O NATURALE CON LA SUPERFICIE DEL TERRENO.

LOCALIZZARE LA PIANTA AL CENTRO DEL POZZETTO. L'APPALTATORE È RESPONSABILE DELLA STABILITÀ E DELLA MESSA A PIOMBO DI TUTTI GLI ALBERI E ARBUSTI E DEVE ESSERE

LEGALMENTE RINTRACCIABILE PER QUALSIASI DANNO CAUSATO DALL'INSTABILITÀ DI QUALSIASI MATERIALE VEGETALE.

17. ALL INJURED ROOTS SHALL BE PRUNED TO MAKE CLEAN ENDS BEFORE PLANTING UTILIZING CLEAN, SHARP TOOLS. PRUNE DEAD, DISEASED OR DAMAGED TISSUE FROM ALL

PLANTS. MAIN LEADER OF TREES SHALL NOT BE CUT BACK. CARE SHALL BE TAKEN TO PRESERVE EXISTING TREES AND ROOT SYSTEMS. EXISTING TREES INCURRING ROOT DAMAGE

DUE TO CONSTRUCTION SHALL BE PRUNED WITH CLEAN, SHARP TOOLS. /

TUTTE LE RADICI DANNEGGIATE DEVONO ESSERE POTATE IN MODO DA OTTENERE ESTREMITÀ PULITE PRIMA DI ESSERE PIANTATE UTILIZZANDO ATTREZZI PULITI E AFFILATI. POTARE

I TRATTI MORTI, MALATI O DANNEGGIATI DI TUTTE LE PIANTE. I RAMI PRINCIPALI DEGLI ALBERI NON DEVONO ESSERE TAGLIATI. OCCORRE PRESTARE ATTENZIONE A PRESERVARE

GLI ALBERI E LE RADICI ESISTENTI. GLI ALBERI ESISTENTI CHE SUBISCONO DANNI ALLE RADICI A CAUSA DELLA COSTRUZIONE DEVONO ESSERE POTATI CON ATTREZZI PULITI E

AFFILATI.

18. CONTRACTOR SHALL REGRADE ALL AREAS DISTURBED BY PLANT REMOVAL, RELOCATION, AND/OR INSTALLATION WORK. ALL PLANTING BEDS SHALL BE MULCHED PER THE

SPECIFICATIONS. /

L'APPALTATORE È TENUTO A MODIFICARE LA PENDENZA DI TUTTE LE AREE DISTURBATE DALLA RIMOZIONE DELLE PIANTE, DAL TRASFERIMENTO E/O DAI LAVORI DI INSTALLAZIONE.

TUTTE LE AIUOLE DEVONO ESSERE PACCIAMATE SECONDO LE SPECIFICHE.

19. ALL PLANTING AREAS SHALL BE ADEQUATELY WATERED TO ESTABLISH THE PROPOSED PLANTS. /

TUTTE LE AREE DI PIANTUMAZIONE DEVONO ESSERE ADEGUATAMENTE INNAFFIATE PER CONSENTIRE L'INSEDIAMENTO DELLE PIANTE PROPOSTE

20. ALL PLANTS SHOWN ON THE APPROVED LANDSCAPE PLAN SHALL BE INSPECTED AND APPROVED BY THE CONTRACTING OFFICER. THE CONTRACTING OFFICER SHALL TAKE INTO

ACCOUNT SEASONAL CONSIDERATIONS IN THIS REGARD. /

TUTTI GLI INSTALLAZIONI CHE FIGURANO SUL PIANO PAESAGGISTICO APPROVATO DEVONO ESSERE ISPEZIONATI E APPROVATI DALL'AGENTE CONTRATTUALE. L'AGENTE

CONTRATTUALE TIENE CONTO DI CONSIDERAZIONI STAGIONALI AL RIGUARDO.

21. FINAL LOCATION FOR PLANT MATERIAL AND PLANTING BEDS SHALL BE SUBJECT TO THE CONTRACTING OFFICER'S APPROVAL. CONTRACTOR SHALL OBTAIN APPROVAL FOR

LOCATIONS PRIOR TO DIGGING OR INSTALLATION. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER 72 HOURS PRIOR TO DELIVERY AND INSTALLATION OF LANDSCAPE

PLANTS, SO THAT THEY MAY BE ON SITE TO INSPECT PLANT MATERIAL AND VIEW INSTALLATION. /

L'UBICAZIONE DEFINITIVA DEL MATERIALE VEGETALE E DEI LETTI DI IMPIANTO È SOGGETTA ALL'APPROVAZIONE ALL'UFFICIALE CONTRAENTE. L'APPALTATORE DEVE OTTENERE

L'APPROVAZIONE DEI SITI PRIMA DELLO SCAVO O DELL'INSTALLAZIONE. IL CONTRAENTE DEVE NOTIFICARE UFFICIALE CONTRAENTE 72 ORE PRIMA DELLA CONSEGNA E

DELL'INSTALLAZIONE DELLE PIANTE DA PAESAGGIO, IN MODO CHE POSSANO ESSERE SUL POSTO PER ISPEZIONARE IL MATERIALE VEGETALE E VISIONARE L'INSTALLAZIONE.

22. MAINTENANCE SHALL BEGIN AFTER EACH PLANT HAS BEEN INSTALLED AND SHALL CONTINUE UNTIL THE PROJECT HAS BEEN DEEMED SUBSTANTIALLY COMPLETE. MAINTENANCE

INCLUDES WATERING, PRUNING, WEEDING, MULCHING, REPLACEMENTS OF SICK OR DEAD PLANTS, AND ANY OTHER CARE NECESSARY FOR THE PROPER GROWTH OF THE PLANT

MATERIALS. /

LA MANUTENZIONE INIZIA DOPO L'INSTALLAZIONE DI CIASCUNA PIANTA E PROSEGUE FINO A QUANDO IL PROGETTO NON SIA STATO RITENUTO SOSTANZIALMENTE COMPLETO. LA

MANUTENZIONE COMPRENDE L'IRRIGAZIONE, LA POTATURA, IL DISERBO, LA PACCIAMATURA, LA SOSTITUZIONE DI PIANTE MALATE O MORTE E QUALSIASI ALTRA CURA NECESSARIA

PER LA CORRETTA CRESCITA DEI MATERIALI VEGETALI.

23. CONTRACTOR SHALL SUBMIT WRITTEN GUARANTEE OF SURVIVABILITY OF ALL PLANT MATERIALS FOR A PERIOD OF ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION. /

L'APPALTATORE DEVE PRESENTARE UNA GARANZIA SCRITTA DI SOPRAVVIVENZA DI TUTTE LE PIANTE PER UN PERIODO DI UN ANNO DALLA DATA DI COMPLETAMENTO SOSTANZIALE.

24. ALL DISTURBED AREAS (AND OTHER AREAS ON SITE WHERE GRASS IS NOT ESTABLISHED) SHALL BE TREATED WITH 100MM TOPSOIL AND SEEDED IN ACCORDANCE WITH

PERMANENT STABILIZATION METHODS INDICATED ON SOIL EROSION AND SEDIMENT CONTROL SHEET. /

TUTTE LE AREE DISTURBATE (E LE ALTRE AREE DEL SITO IN CUI NON È PRESENTE L'ERBA) DEVONO ESSERE TRATTATE CON 100 mm DI TERRENO VEGETALE IN SUPERFICIE E

SEMINATE SECONDO I METODI DI STABILIZZAZIONE PERMANENTE INDICATI SUL FOGLIO DI CONTROLLO DELL'EROSIONE DEL SUOLO E DEI SEDIMENTI.

D

TE

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:3 :3

B

IM

B P A M E R

V ic e n z a p h a se

III

A F H P S

IT

E S .r vt

MH OTVPP

S

TR

U C

TU

R

A L

G E

N E

R A

L N

O

TE

S N

O

TE

G E

N E

R A

LI

S

TR

U

TT

U

R E

S-001

14105950

1656273

V P P

1. INTERNATIONAL BUILDING CODE (2018 EDITION)

2. ACI 318-14 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE

3. UFC 1-200-01 GENERAL BUILDING REQUIREMENTS, ( OCTOBER 1, 2020)

4. UFC 1-300-09N DESIGN PROCEDURES, WITH CHANGE 4, 14 JUNE 2018

5. UFC 3-301-01 STRUCTURAL ENGINEERING, (OCTOBER 1, 2019)

6. UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 12

DECEMBER 2018

7. ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER

STRUCTURES

8. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) SPECIFICATION FOR

THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR

BUILDINGS, FIFTEENTH EDITION

9.AWS STRUCTURAL WELDING CODE (2015 EDITION)

10. ACI 350/350R-06 CODE REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING

CONCRETE STRUCTURES

11. D.M., CONSTRUCTION CODE (17 JANUARY 2018)

12. CIRCOLARE DEL 21 GENNAIO 2019 N. 7. INSTRUCTIONS FOR THE

APPLICATION OF THE UPDATE OF THE TECHNICAL STANDARDS FOR

CONSTRUCTION REFERRED TO IN THE MINISTERIAL DECREE OF 17 JANUARY

13. LAW N. 1086, NORMS RELATED TO NORMAL AND PRE-STRESSED

REINFORCED CONCRETE STRUCTURES AND STEEL STRUCTURES (5

NOVEMBER 1971)

14. LAW N. 64, PROVISIONS FOR STRUCTURES, WITH SPECIAL PRESCRIPTIONS

FOR THE SEISMIC ZONES (2 FEBRUARY 1974)

15. UNI EN 1090: EXECUTION OF STEEL AND ALUMINUM STRUCTURES

16. UNI EN 206: CONCRETE. SPECIFICATION, PERFORMANCE, PRODUCTION AND

COMPLIANCE

17. UNI 11104: CONCRETE. SPECIFICATION, PERFORMANCE, PRODUCTION AND

COMPLIANCE. COMPLEMENTARY INSTRUCTIONS FOR THE APPLICATION OF EN

206-1

18. UNI 8520: AGGREGATES FOR CONCRETE. COMPLEMENTARY INSTRUCTIONS

FOR THE APPLICATION OF EN 1262

19. UNI 7122: TEST ON FRESH CONCRETE. DETERMINATION OF THE AMOUNT OF

EXUDED MIXING WATER

20. EN 10080: STEEL FOR THE REINFORCEMENT OF CONCRETE

21. UNI EN 13670: EXECUTION OF CONCRETE STRUCTURES – GENERAL

REQUIREMENTS

22. CNR-DT 207/2008: INSTRUCTIONS FOR EVALUATING WIND ACTIONS AND

EFFECTS ON BUILDINGS

1. CODICE INTERNAZIONALE DELL'EDILIZIA (EDIZIONE 2018)

2. ACI 318-14 REQUISITI DEL CODICE EDILIZIO PER IL CALCESTRUZZO ARMATO

3. UFC 1-200-01 REQUISITI GENERALI PER GLI EDIFICI, (1 OTTOBRE 2020)

4. UFC 1-300-09N PROCEDURE DI PROGETTAZIONE, CON MODIFICA 4, 14

GIUGNO 2018

5. UFC 3-301-01 INGEGNERIA STRUTTURALE, (1 OTTOBRE 2019)

6. UFC 4-010-01 DOD STANDARD MINIMI ANTITERRORISMO PER GLI EDIFICI, 12

DICEMBRE 2018

7. ASCE 7-16 CARICHI MINIMI DI PROGETTO PER EDIFICI E ALTRE STRUTTURE

8. ISTITUTO AMERICANO PER LE COSTRUZIONI IN ACCIAIO (AISC) SPECIFICA

PER LA PROGETTAZIONE, LA FABBRICAZIONE E L'EREZIONE DELL'ACCIAIO

STRUTTURALE PER LE COSTRUZIONI, QUINDICESIMA EDIZIONE

9.AWS CODICE DI SALDATURA STRUTTURALE (EDIZIONE 2015)

10. ACI 350/350R-06 REQUISITI DEL CODICE PER STRUTTURE IN CALCESTRUZZO

DI INGEGNERIA AMBIENTALE

11. D.M., CODICE DI COSTRUZIONE (17 GENNAIO 2018)

12. CIRCOLARE DEL 21 GENNAIO 2019 N. 7. ISTRUZIONI PER L'APPLICAZIONE

DELL'AGGIORNAMENTO DELLE NORME TECNICHE PER LE COSTRUZIONI DI CUI

AL DECRETO MINISTERIALE 17 GENNAIO 2018

13. LEGGE N. 1086, NORME RELATIVE ALLE STRUTTURE IN CALCESTRUZZO

ARMATO NORMALE E PRECOMPRESSO E ALLE STRUTTURE IN ACCIAIO (5

NOVEMBRE 1971)

14. LEGGE N. 64, DISPOSIZIONI PER LE STRUTTURE, CON PRESCRIZIONI

SPECIALI PER LE ZONE SISMICHE (2 FEBBRAIO 1974)

15. UNI EN 1090: ESECUZIONE DI STRUTTURE IN ACCIAIO E ALLUMINIO

16. UNI EN 206: CALCESTRUZZO. SPECIFICHE, PRESTAZIONI, PRODUZIONE E

CONFORMITÀ

17. UNI 11104: CALCESTRUZZO. SPECIFICHE, PRESTAZIONI, PRODUZIONE E

CONFORMITÀ. ISTRUZIONI COMPLEMENTARI PER L'APPLICAZIONE DELLA EN

206-1

18. UNI 8520: AGGREGATI PER CALCESTRUZZO. ISTRUZIONI COMPLEMENTARI

PER L'APPLICAZIONE DELLA EN 1262

19. UNI 7122: TEST SUL CALCESTRUZZO FRESCO. DETERMINAZIONE DELLA

QUANTITÀ DI ACQUA D'IMPASTO TRASUDATA

20. EN 10080: ACCIAIO PER L'ARMATURA DEL CALCESTRUZZO

21. UNI EN 13670: ESECUZIONE DI STRUTTURE DI CALCESTRUZZO - REQUISITI

GENERALI

22. CNR-DT 207/2008: ISTRUZIONI PER LA VALUTAZIONE DELLE AZIONI DEL

VENTO E DEGLI EFFETTI SUGLI EDIFICI

CODES NORMATIVE DESING LOADS CARICHI DI PROGETTAZIONE

DESIGN LOADS ARE IN ACCORDANCE WITH UFC 3-310-01, UFC 3-310-04, ASCE7,

IBC 2018, ITALIAN LAW 1086(5/11/71), LAW 64(2/02/74), DM (17/01/18)

1. LIVE LOADS:

ROOF . . . . . . . . . 1 Kpa FLOOR . . . . . . . . . 2.0 Kpa BALCONY . . . . . . . 4.8 Kpa ELEVATOR LOBBY AND STAIRS. . . 4.8 Kpa

2. SUPERIMPOSED LOADS:

CEILING, MEP SYSTEMS AND PV PANELS 1 Kpa FLAT ROOF 0.4 kpa PITCH ROOF 0.8 kpa

3. WIND LOAD APARTMENTS AND TOWNHOUSES:

Vu ULTIMATE WIND SPEED (3 SECOND GUST) . . 41 m/s OR 148 km/h

STRUCTURAL CLASSIFICATION ENCLOSED

RISK CATEGORY . . . II

WIND EXPOSURE . . . B

INTERNAL PRESSURE COEFFICIENT GcPI=±0.18

4. WIND LOAD SUBSTATION:

Vu ULTIMATE WIND SPEED (3 SECOND GUST) . . 44 m/s OR 158 km/h

STRUCTURAL CLASSIFICATION ENCLOSED

RISK CATEGORY . . . IV

WIND EXPOSURE . . . B

INTERNAL PRESSURE COEFFICIENT GcPI=±0.18

5. WIND LOAD (ITALIAN CODE)

Vb,0 BASIC WIND SPEED . . .25 m/s BASIC VELOCITY PRESSURE, qb = 0.39 kPa

ROUGHNESS B

EXPOSURE CATEGORY: IV

INTERNAL PRESSURE COEFFICIENT: DEPENDES ON THE NUMBER OF

OPENINGS CPI (min 0/ max±0.40)

6. SEISMIC PARAMETERS (US CODE) APARTMENTS AND TOWNHOUSES:

SEISMIC IMPORTANCE FACTOR 1.0

MAPPED SPECTRAL RESPONSE ACCELERATIONS

Ss 0.76g S1 0.21g

SITE CLASS D

SPECTRAL RESPONSE COEFFICIENT

SDs 0.606g SD1 0.305g

SEISMIC DESIGN CATEGORY D

STRUCTURAL SYSTEM SPECIAL REINFORCED CONCRETE SHEAR WALL

RESPONSE MODIFICATION FACTOR R=5

SYSTEM OVERSTRENGTH FACTOR Ω=2.5

DEFLECTION AMPLIFICATION FACTOR Cd=5

7. SEISMIC PARAMETERS (US CODE) SUBSTATION:

SEISMIC IMPORTANCE FACTOR 1.5

MAPPED SPECTRAL RESPONSE ACCELERATIONS

Ss 0.76g S1 0.21g

SITE CLASS D

SPECTRAL RESPONSE COEFFICIENT

SDs 0.606g SD1 0.305g

SEISMIC DESIGN CATEGORY D

SUBSTATION

STRUCTURAL SYSTEM SPECIAL REINFORCED CONCRETE SHEAR WALL

RESPONSE MODIFICATION FACTOR R=5

SYSTEM OVERSTRENGTH FACTOR Ω=2.5

DEFLECTION AMPLIFICATION FACTOR Cd=5

8.SEISMIC PARAMETERS (ITALIAN CODE):

SITE CLASS C

SERVICEABILITY LIFE Vn=50 YEARS

OCCUPANCY CLASS II

OCCUPANCY FACTOR Cu=1.0

REFERENCE LIFE 50 YEARS

SOIL ACCELERATION FACTOR SLV ag/g=0.147g

RETURN PERIOD SLV 475

9. SNOW LOAD(US CODE):

GROUND SNOW LOAD 1.68 Kpa

IMPORTANCE FACTOR 1.0

10. SNOW LOAD (ITALIAN CODE):

GROUND SNOW LOAD 1.50 Kpa

EXPOSURE COEFFICIENT 1.0

I CARICHI DI PROGETTO SONO CONFORMI A UFC 3-310-01, UFC 3-310-04, ASCE7,

IBC 2018, LEGGE 1086(5/11/71), LEGGE 64(2/02/74), DM (17/01/18)

1. CARICHI VARIABILI:

TETTO. . . . . . . . . 1 Kpa PAVIMENTO . . . . . . . . 2.0 Kpa BALCONE . . . . . . 4.8 Kpa ATRIO DELL'ASCENSORE E SCALE ......4.8 Kpa

2. CARICHI PERMANENTI:

SOFFITTO, SISTEMI MEP E PANNELLI FV 1 Kpa TETTO PIANO 0,4 kpa TETTO A FALDE 0,8 kpa.

3. CARICO DA VENTO APPARTAMENTI E TOWNHOUSES:

VELOCITÀ MASSIMA DEL VENTO (RAFFICA DI 3 SECONDI) . 41 m/s O 148 km/h

CLASSIFICAZIONE STRUTTURALE: CHIUSO

CATEGORIA DI RISCHIO . . II

ESPOSIZIONE AL VENTO . . . B

COEFFICIENTE DI PRESSIONE INTERNA GcPI=±0,18

4. CARICO DA VENTO SOTTOSTAZIONE:

VELOCITÀ MASSIMA DEL VENTO (RAFFICA DI 3 SECONDI) . 44 m/s O 158 km/h

CLASSIFICAZIONE STRUTTURALE: CHIUSO

CATEGORIA DI RISCHIO . . IV

ESPOSIZIONE AL VENTO . . . B

COEFFICIENTE DI PRESSIONE INTERNA GcPI=±0,18

5. CARICO DA VENTO (CODICE ITALIANO)

Vb,0 VELOCITÀ DI RIFERIMENTO DEL VENTO . .25 m/s PRESSIONE DI VELOCITÀ DI BASE, qb = 0,39 kPa

RUGOSITA' B

CATEGORIA DI ESPOSIZIONE: IV

COEFFICIENTE DI PRESSIONE INTERNA: DIPENDE DAL NUMERO DI APERTURE

CPI (min 0/ max±0,40)

6. PARAMETRI SISMICI (CODICE US) APPARTAMENTI E TOWNHOUSES:

FATTORE DI IMPORTANZA SISMICA 1.0

PARAMETRI ACCELERAZIONI SPETTRALI

Ss 0.76g S1 0.21g

CATEGORIA DI SOTTOSUOLO D

COEFFICIENTI SPETTRO DI RISPOSTA ELASTICO

SDs 0.606g SD1 0.305g

CATEGORIA DI PROGETTAZIONE SISMICA D

SISTEMA STRUTTURALE: PARETI SPECIALI A TAGLIO IN CALCESTRUZZO

ARMATO

FATTORE DI COMPORTAMENTO R=5

FATTORE DI SOVRARESISTENZA Ω=2,5

FATTORE DI AMPLIFICAZIONE DELLA DEFLESSIONE Cd=5

7. PARAMETRI SISMICI (CODICE US) SOTTOSTAZIONE:

FATTORE DI IMPORTANZA SISMICA 1,5

PARAMETRI ACCELERAZIONI SPETTRALI

Ss 0.76g S1 0.21g

CATEGORIA DI SOTTOSUOLO D

COEFFICIENTI SPETTRO DI RISPOSTA ELASTICO

SDs 0.606g SD1 0.305g

CATEGORIA DI PROGETTAZIONE SISMICA D

SOTTOSTAZIONE

SISTEMA STRUTTURALE PARETI SPECIALI A TAGLIO IN CALCESTRUZZO ARMATO

FATTORE DI COMPORTAMENTO R=5

FATTORE DI SOVRARESISTENZA Ω=2,5

FATTORE DI AMPLIFICAZIONE DELLA DEFLESSIONE Cd=5

8.PARAMETRI SISMICI (CODICE ITALIANO):

CATEGORIA DI SOTTOSUOLO C

VITA NOMINALE Vn=50 ANNI

CLASSE D'USO II

COEFFICIENTE D'USO Cu=1,0

VITA DI RIFERIMENTO 50 ANNI

ACCELERAZIONE AL SUOLO SLV ag/g=0,147g

PERIODO DI RITORNO SLV 475

9. CARICO DA NEVE (CODICE US):

CARICO DA NEVE AL SUOLO 1.68 Kpa

FATTORE DI IMPORTANZA 1.0

10. CARICO DA NEVE (CODICE ITALIANO):

CARICO DA NEVE AL SUOLO 1,50 Kpa

COEFFICIENTE DI ESPOSIZIONE 1.0

D

TE

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:3 :3

B

IM

B P A M E R

V ic e n z a p h a se

III

A F H P S

IT

E S .r vt

MH OTVPP

S

TR

U C

TU

R

A L

G E

N E

R A

L N

O

TE

S N

O

TE

G E

N E

R A

LI

S

TR

U

TT

U

R E

S-002

14105951

1656273

V P P

1. GENERAL NOTES AND TYPICAL DETAILS APPLY TO ALL STRUCTURAL

FEATURES UNLESS OTHERWISE SHOWN OR NOTED. IF CERTAIN FEATURES

ARE NOT FULLY SHOWN OR CALLED FOR ON THE DRAWINGS OR

SPECIFICATIONS, THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER

AS FOR SIMILAR CONDITIONS

2. ANCHORS ARE TO BE INSTALLED WITHIN A TOLERANCE OF 6mm OF

SPECIFIED LOCATION

3. A SOIL OR WASTE PIPE OR A BUILDING DRAIN, ETC PASSING UNDER A

FOOTING OR THROUGH A FOUNDATION WALL SHALL BE PROVIDED WITH A

RELIEVING ARCH, OR THERE SHALL BE BUILT INTO THE WALL OR FOUNDATION

AN IRON PIPE SLEEVE TWO PIPE SIZES GREATER THAN THE PIPE PASSING

THROUGH FOR PIPES 150mmø AND LESS AND ONE PIPE SIZE GREATER THAN THE PIPE PASSING THROUGH FOR PIPES GREATER THAN 150mmø.

4. THE STRUCTURES ARE DESIGNED TO BE SELF-SUPPORTING AND STABLE

AFTER THE BUILDING IS FULLY COMPLETED. IT IS THE CONTRACTOR'S

RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND

TO ENSURE THE SAFETY OF WORKERS, THE BUILDING AND ITS COMPONENT

PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER

SHORING,TEMPORARY BRACING, ETC. THAT MAY BE NECESSARY AS WELL AS

FULL COMPLIANCE WITH ALL APPLICABLE OSHA REGULATIONS. OBSERVATION

VISITS TO THE SITE BY AECOM PERSONAL SHALL NOT INCLUDE INSPECTION

FOR THESE ITEM.

5. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO ENSURE ALL WORK IS

PERFORMED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.

6. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF OPENING AND

HEIGHTS OF ALL WALLS NOT SHOWN OR OTHERWISE NOTED ON THE

STRUCTURAL DRAWINGS.

7. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SIZE AND

LOCATION OF ALL FLOOR AND ROOF OPENINGS NOT SHOWN OR OTHERWISE

NOTED ON THE STRUCTURAL DRAWINGS.

8. DIMENSIONS SHALL NOT BE SCALED

9. CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND DIMENSIONS

RELATIVE TO SAME. WHERE THERE ARE CONFLICTS BETWEEN ACTUAL FIELD

CONDITIONS AND/OR DATA PRESENTED ON THESE DRAWINGS, SUCH INFORM

THE GEOTECHNICAL & ENGINEER IMMEDIATELY, AND DEVELOPE NECESSARY

ADJUSTMENTS MADE PER THEIR INSTRUCTIONS.

10. COORDINATE BONDING OF FOUNDATION REBAR TO ELECTRICAL GROUND

WITH ELECTRICAL CONTRACTOR.

11. SPECIALTY ENGINEER REQUIREMENTS: A LICENSED PROFESSIONAL

ENGINEER, WHO IS NOT THE STRUCTURAL ENGINEER OF RECORD, WHO

PROVIDES ENGINEERING CRITERIA OR DESIGNS NECESSARY FOR THE

STRUCTURE TO BE COMPLETED. THE SPECIALTY ENGINEER MAY BE A

DELEGATED ENGINEER.

12. SPECIFICATIONS, CODES, AND STANDARDS NOTED IN THESE CONTRACT

DOCUMENTS SHALL BE OF THE LATEST EDITION APPROVED BY THE

APPROPRIATE REGULATORY AGENCIES.

13. SHOP DRAWINGS AND CALCULATIONS FOR ALL STOREFRONT SYSTEMS,

CANOPIES, AND SPECIALTY ENGINEERED BUILDING ELEMENTS MUST BE

SIGNED AND SEALED BY THE CURRENTLY LICENSED ENGINEER RESPONSIBLE

FOR THE DESIGN AT TIME OF SUBMISSION

14. THE CONTRACTOR SHALL PROVIDE AND INSTALL THE FOLLOWING

PREFABRICATED ITEMS AS INDICATED IN THE DRAWINGS AND SPECIFICATIONS:

• PRESTRESSED "PREDALLE" TYPE CONCRETE PLANKS WITH CAST-IN-PLACE

TOPPING SLAB.

• IGLOO SLABS WITH POLYPROPYLENE FORMS AND CAST-IN-PLACE CONCRETE

SLAB

THEIR INSTALLATION SHALL BE COORDINATED WITH CAST-IN-PLACE PORTIONS

OF THE STRUCTURE PRIOR TO CONCRETE POURING OPERATIONS.

1. THE EXCAVATION OF ALL DEBRIS-LADEN MATERIALS AND SUBSEQUENT

REPLACEMENT WITH COMPACTED FILL LOCATED BENEATH THE ENTIRE

STRUCTURE FOOTPRINT PLUS A 1.5M MARGIN OUTSIDE THE PERIMETER

FOUNDATION IN STRICT ACCORDANCE WITH ALL OF THE RECOMMENDATIONS

BY GEOTECHNICAL ENGINEER FOR THIS PROJECT.

2.THE DEGREE OF COMPACTION OF ANY GRANULAR MATERIALS USED TO

REACH THE FINAL PROJECT LEVEL MUST BE VERIFIED BY TESTS ON A

CIRCULAR PLATE WITH A DIAMETER OF 30 CM THROUGH A DOUBLE LOADING

AND UNLOADING CYCLE ACCORDING TO THE RECOMMENDATIONS OF CNR

146/1992

3. FOUNDATIONS SHALL NOT BE PLACED ABOVE SLOPES EXCEEDING ONE

VERTICAL AND TWO HORIZONTAL AS MEASURED FROM THE CLOSEST EDGE OF

ANY UNDISTURBED SOIL OR OTHER FOUNDATION STRUCTURE.

4. ALL FOUNDATIONS SHALL BE CENTERED UNDER COLUMN OR WALL

CENTERLINES UNLESS SHOWN OR NOTED OTHERWISE.

5. REPORT ANY UNUSUAL BELOW GRADE CONDITIONS ENCOUNTERED TO THE

STRUCTURAL ENGINEER.

6. SLAB ON GRADE WILL BE SUPPORTED BY HIGH STRENGTH PLASTIC

MODULES TO PROVIDE CRAWL SPACE.

7. FOUNDATION DESIGN IS BASED ON SOIL REPORT "GEOTECHNICAL

INVESTIGATION REPORT - PHASE 1-4" PREPARED BY AECOM DATED 26TH

OCTOBER 2021.

8. CFA-TYPE REINFORCED LOAD-BEARING PILES SHALL BE INSTALLED IN

ACCORDANCE WITH THE CRITERIA ESTABLISHED BY THE DESIGNER. THE

TOTAL SETTLEMENT, UNDER SERVICE LOADS, MUST BE LIMITED TO 25 MM

ACCORDING TO THE INDICATIONS OF UFC 3-220-01 GEOTECHNICAL

ENGINEERING.

9. A GEOTECHNICAL ENGINEER SHALL OBSERVE THE OPEN EXCAVATION TO

DETERMINE THAT THE SOIL TYPE AND CONDITIONS ARE CONSISTENT WITH

DESIGN CRITERIA OF THE SOIL REPORT. IF THE SOIL PROPERTIES ARE FOUND

TO BE DIFFERENT FROM THIS CRITERIA THE OWNER’S REPRESENTATIVE SHALL

BE PROMPTLY NOTIFIED SO THAT THE FOUNDATION DESIGN MAY BE

REVIEWED.

10. TO MINIMIZE WEATHERING, THE LAST 150 mm OF EXCAVATION FOR ALL

SLABS SHALL BE MADE IMMEDIATELY PRIOR TO POURING OF SLAB.

11. QUALITY ASSURANCE COMPACTION DENSITY UNDER FOOTINGS AND SLABS

SHALL BE A MINIMUM OF "95%" OF THE MAXIMUM DRY DENSITY AS

DETERMINED BY ASTM D-1557 (MODIFIED PROCTOR) THROUGHOUT EACH 300

mm LIFT, TO A DEPTH AS INDICATED IN THE GEOTECHNICAL REPORT. IN

ADDITION TO THIS MINIMUM COMPACTION REQUIREMENT, THE BEARING SOILS

MUST EXHIBIT STABILITY AND BE FREE OF "PUMPING" CONDITIONS.

12. BELOW THE SLAB ON GRADE, A DEFORMATION MODULUS OF 80MPA SHALL

BE REACHED AFTER COMPACTION OF THE SOIL; PLATE LOAD TESTS CARRIED

OUT BY AN AUTHORIZED LABORATORY ARE REQUIRED

13. PILE LOAD TESTS HAVE TO BE CARRIED OUT FOLLOWING REQUIREMENTS

GIVEN BY NTC18, SECTION 6.4.3.7.2.

THE BUILDING CONTROLLER (COLLAUDATORE) DURING THE EXECUTION OF

THE WORKS AND/OR THE DIRECTOR OF WORKS WILL DECIDE NUMBER AND

LOCATION OF THE TESTS, MAINTAINING REQUIREMENTS OF NTC18 AS A

MINIMUM.

THE PROGRAM OF TESTS REQUIRED BY THE BUILDING CONTROLLER, WITH

THE INDICATION OF THE LOADING PROCEDURE AND THE EXPECTED

PERFORMANCES (DEFORMATIONS, STRESS LEVELS, REACTION OF THE

CONSTRAINTS, ETC.), MUST BE:

- SUBMITTED TO THE DIRECTOR OF WORKS FOR IMPLEMENTATION;

- MADE KNOWN TO THE DESIGNER, SO THAT HE CAN VERIFY ITS COMPATIBILITY

WITH THE STRUCTURAL DESIGN;

- MADE KNOWN TO THE CONTRACTOR FOR ACCEPTANCE AND EXECUTION

1. LE NOTE GENERALI E I DETTAGLI TIPICI SI APPLICANO A TUTTE LE

CARATTERISTICHE STRUTTURALI A MENO CHE NON SIA MOSTRATO O

ANNOTATO DIVERSAMENTE. SE ALCUNE CARATTERISTICHE NON SONO

COMPLETAMENTE MOSTRATE O RICHIESTE NEI DISEGNI O NELLE SPECIFICHE,

LA LORO COSTRUZIONE DEVE SEGUIRE LO STESSO PRINCIPIO SEGUITO IN

CONDIZIONI SIMILI

2. GLI ANCORAGGI DEVONO ESSERE INSTALLATI ENTRO UNA TOLLERANZA DI 6

mm DALLA POSIZIONE SPECIFICATA

3. UN TUBO DI TERRA O DI SCARICO O UN DRENAGGIO DELL'EDIFICIO, ECC.

CHE PASSA SOTTO UN BASAMENTO O ATTRAVERSO UN MURO DI FONDAZIONE

DEVE ESSERE DOTATO DI APPOSITA PROTEZIONE AD ARCO, OPPURE DEVE

ESSERE COSTRUITO NEL MURO O NELLA FONDAZIONE UN MANICOTTO IN

FERRO DI DUE DIMENSIONI MAGGIORI DEL TUBO CHE PASSA PER I TUBI DI

DIAMETRO INFERIORE A 150mmø E UNA DIMENSIONE MAGGIORE DEL TUBO CHE Passa PER TUBI SUPERIORI A 150mmø.

4. QUESTE STRUTTURE SONO PROGETTATE PER ESSERE AUTOPORTANTI E

STABILI DOPO CHE LA COSTRUZIONE DELL'EDIFICIO È ULTIMATA. È

RESPONSABILITÀ DELL'APPALTATORE DETERMINARE LA PROCEDURA E LA

SEQUENZA DI MONTAGGIO E GARANTIRE LA SICUREZZA DEI LAVORATORI,

DELL'EDIFICIO E DELLE SUE PARTI COMPONENTI DURANTE IL MONTAGGIO.

QUESTO INCLUDE L'AGGIUNTA DI QUALSIASI PUNTELLAMENTO, RINFORZO

TEMPORANEO, ECC. CHE POSSONO ESSERE NECESSARI, COSÌ COME IL PIENO

RISPETTO DI TUTTI I REGOLAMENTI OSHA APPLICABILI. LE VISITE DI

OSSERVAZIONE AL SITO DA PARTE DEL PERSONALE AECOM NON INCLUDONO

L'ISPEZIONE DI QUESTI ELEMENTI.

5. È ESCLUSIVA RESPONSABILITÀ DELL'APPALTATORE ASSICURARE CHE TUTTO

IL LAVORO SIA ESEGUITO IN CONFORMITÀ AI DOCUMENTI DEL CONTRATTO.

6. FARE RIFERIMENTO AI DISEGNI ARCHITETTONICI PER LE POSIZIONI DELLE

APERTURE E LE ALTEZZE DI TUTTE LE PARETI NON MOSTRATE O ALTRIMENTI

ANNOTATE SUI DISEGNI STRUTTURALI.

7. FARE RIFERIMENTO AI DISEGNI ARCHITETTONICI E MECCANICI PER LE

DIMENSIONI E LA POSIZIONE DI TUTTE LE APERTURE DEL PAVIMENTO E DEL

TETTO NON MOSTRATE O…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .