Attachment H - 1656273dwg11of29.pdf
PDF 27 MB Posted
- Solicitation number
- N6247022R0002
About this file
This solicitation is for Phase 3 Family Housing at Villaggio, Vicenza, Italy. The Naval Facilities Engineering Command is seeking offers for the construction of additional military family housing units at Villaggio in Vicenza. Offerors must submit proposals no later than May 2, 2022. The work includes providing all labor, materials, equipment, and supervision to complete construction of approximately 80 family housing units in 5 buildings. The units will be 2-3 bedroom apartments ranging from 65 to 110 square meters. The construction must meet all applicable military construction standards and be completed within 720 calendar days of award. The awarded firm will be responsible for all associated site work, utilities, landscaping, and community amenities.
View the file
Other files
Show 40 more
Latest 50 of 61 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C O
M M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
CO
M
M
COMM
CO
M M
C O
M M
C O
M M
C O
M M
C O
M M
COMM COMM COMM COMM
CO
M
M C
O M
M C
O M
M C
O M
M
COMM
COMM
TV
HH
MH-31A
HH
HH
HH
HH
HH
HH
HH
COMM
COMM
COMM
C O
M M
COMM
CO
M
M
CO
M M
CO
M
M
COMM
COMM
COMM
COMM
CO
MM
COMM
COMM
COMM
COMM
COMM
COMM
COMM
CO
M
M
CO
M
M
C O
M M
C O
M M
COMM
C O
M M
COMM
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
C O
M M
MH-31
MH-32
COMM COMM COMM COMM COMM
COMM
COMM
C O
M M
C O
M M
C O
M M
SAN
SA
N
SAN
SAN
SAN
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
G G
G G
G G
G G
G G
G G
G G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G G
G G
G G
G G
G
G
G G
G G
G
G
G
G
G
G
G G
G G
G
G
G
G
G
G
G
G
G G
G G
1+
1+
1+
1+
1+280
1+300
1+320
1+340
1+360
1+
1+
1+
1+
1+
0 P
E8
0 P
E8
100 PE80
100 PE80
0 P
E8
G
G
G
G
G
G G
G
G
G G
G G
G
G
G
G
G
FF
F
F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F F
F
F
F
F
F
F
F
F
F
F
F
F F
F
F F
F F
F F F
F F F F F
F F F F
F F F F
F
F F F F
F F
F F F F
F F F F F F F F
F
F F
F
F F
F F
F F
F
FUSL
USL
U
SL
USL
USL
USL
U
SL
U
SL
U
SL
U
SL
US
L
USL USL USL USL
U
SL
U
SL
U
SL
U
SL
USL
USL
USL
U
SL
USL
USL
USL
USL
USL
USLUSLUSLUSL
U
SL
U
SL
U
SL
U
SL
U
SL
USL
USL
USL
USL
USL
USL
USL
U
SL
U
SL
U
SL
US
L
US
L
US
L
U
SL
USL
U
SL
U
SL
U
SL
U
SL
U
SL
USL
USL
US
L
US
L
US
L
US
L
US
L
USL
USL
USLUSLUSL
U
SL
U
SL
VS3S3-SP-1
USL
USL
USL
USL
U
SL
U
SL
U
SL
U
SL
SUBSTATIONVS3-S3
SUBSTATIONVS3-S3PRV
W
W W
W
W
W
W W
X
X X
X X
X X
X X
X X
X X
X
XXXXXXXXX
X
X X
X X
X X
X X
X X
X X
X X
X
X X X
X X
X X
X
X
X
XXX
XXX
XX
X X
X
X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X X
XXX
X X X
XXXX
X
X X
X
X X
X
X
XXX
X
X
X X
X
X X
X
X
X
X
X
X X
X X
X
X X X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
3 AH
3 AG
2 AH
2 AG
1 CT
3 AH
1 FO
1 CT
3 CB
4 CA
1 QR
2 CL
9 CS
2 FO
1 MG
3 MG
2 CB
3 MS
1 CL
2 AC
1 FO
1 CC
1 CC
1 MG
1 MG
1 CC
3 CR
1 MS
1 MG
6 CC
1 CR
4 CC
5 CS
1 FO
2 QR
2 MG
PIANTUMAZIONELP501
ALBERI, TIPICO
B1 TREE PLANTING, TYPICAL /
PIANTUMAZIONELP501
ARBUSTI, TIPICO
A4 SHRUB PLANTING, TYPICAL /
PLANTING, TYPICAL /LP502
RITOMBAMENTO, TIPICO
A4 GROUNDCOVER
32 lu / 20 lr
98 lu / 60 lr
30 lu / 20 lr 5 lu / 3 lr 85 lu / 65 lr
130 lm/ 130 la
40 lm / 40 la
70 lm / 70 la
8 lm / 8 la
70 lm / 70 la
8 lm / 8 la
135 lm / 135 la
120 lm / 120 la 4 hc
3 mc
3 mc
3 mc
24 lm / 48 aa45 pm /
70 aa
45 pm / 70 aa
30 lm / 60 am
24 lm / 48 aa
115 pm / 65 lm
50 lr / 50 al
60 lr / 60 al
170 lr / 100 al
20 lr / 10 al
80 lr / 45 al
24 lm / 48 aa
3 mc
3 mc
6 mc
3 mc
3 mc
3 mc
3 mc
6 mc
8 mc
550 aa
90 aa
470 aa aa
200 aa
3 vo
120 pm / 40 aa
7 hc
6 mc
4 mc
40 pm / 25 aa
6 mc
1 CC
TYPICAL/ PIANTUMAZIONE DI LP501
ALERBI MULTI-FUSTO, TIPICO
B3MULTI-STEM TREE PLANTING,
PLAN
NORTH
MATCHLINE - SEE SHEET LP104 FOR CONTINUATION / LINEA DI UNIONE - VEDERE TAVOLA LP104 PER CONTINUARE
MATCHLINE - SEE SHEET LP102 FOR CONTINUATION / LINEA DI UNIONE - VEDERE TAVOLA LP102 PER CONTINUARE
LP103
LA
ND
SC
AP
E
PL
AN
TI
NG
P
LA
N
PI
AN
TA
D
I P
IA
NT
UM
AZ
IO
NE
P
AE
SA
GG
IO
La st s av ed b y:
J
EN
N
IF
ER
.R
EN
1(
-1
1-
L as t P lo tte d:
1-
-0
Fi le na m e:
N
A.
AE
C O
M N
ET
.C
O M
\L
FS
\A M
ER
\R
O
AN
O
KE
-U
SR
N K1
\D C
S\
PR
O
JE
C
TS
\B D
L\
\9
_C
AD
_G
IS
\9
_C
AD
\2
0-
SH
EE
TS
\L \1
-V
C 3_
LP
1-
LP
5.
D W
G La st s av ed b y:
J
EN
N
IF
ER
.R
EN
1(
-1 1-
L as t P lo tte d:
1-
-0
Fi le na m e:
N A.
AE
C
O M
N
ET
.C O
M \L
FS
\A
M
ER
\R O
AN
O
KE
-U
SR
N
K1 \D
C S\
PR
O
JE
C
TS
\B
D L\
\9
_C
AD
_G
IS
\9
_C
AD
\2 0-
SH
EE
TS
\L
\1
-V C
3_
LP
1-
LP
5.
D
W G
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
P-
AR
M Y
FA
M
IL
Y
HO
US
IN
G
P
RO
JE
CT
DRAWFORM REVISION: 20 AUGUST 2020
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
5m 10m0 25m 1:250
UNLESS OTHERWISE NOTED, LINEAR DIMENSIONS SHOWN ARE IN METERS.
SE NON ALTRIMENTI INDICATO, LE DIMENSIONI LINEARI SONO IN METRI
KEY PLAN
NO SCALEPIANO STRATEGICO
AS NOTED
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
LP103
GENERAL NOTES THIS SHEET: /
NOTE GENERALI DI QUESTO FOGLIO:
EXISTING TREE TO REMAIN /
ALBERO ESISTENTE CHE DEVE RIMANERE
CANOPY TREE /
ALBERO AD OMBRELLO
EVERGREEN TREE /
ALBERO SEMPREVERDE
SMALL CANOPY TREE, ORNAMENTAL TREE /
ALBERO ORNAMENTALE
SHRUB /
CESPUGLIO
PERENNIALS AND GROUNDCOVER /
PIANTE PERENNI E TAPPEZZAMENTI
SEEDED LAWN /
PRATO SEMINATO
SODDED LAWN /
PRATO RIZOLLATO
SODDED GRASS PAVER /
PAVIMENTAZIONE CON ERBA SEMINATA
PLANTING LEGEND: /
LEGENDA PIANTUMAZIONE:
1. KEEP PLANTS A MINIMUM OF 0.5 METERS FROM APARTMENT
BUILDINGS. /
TENERSE LE PIANTE MINIMO A 0.5m DAGLI APPARTAMENTI.
2. SEE SHEET C-001 FOR CIVIL NOTES AND LEGENDS. /
VEDERE TAVOLA C-001 PER NOTE CIVILI LA LEGENDA.
3. SEE CIVIL SHEETS FOR ADDITIONAL INFORMATION. /
VEDERE LE TAVOLE CIVILI, PER INFORMAZIONI AGGIUNTIVE.
4. SEE SHEET LP501 FOR TREE SUPPORT SCHEDULE AND LP502
FOR PLANT SPACING DETAIL. /
VEDERE TAVOLA LP501 PER L'ABACO DEL SUPPORTO AGLI
ALBERI E LP502 PER DETAGLI DI SPAZIATURA TRA LE PIANTE.
5. SEE SHEET LP601-LP602 FOR PLANTING SCHEDULE AND
PLANTING NOTES. /
VEDERE TAVOLA LP601-LP602 PER PROGRAMMA
PIANTUMAZIONE OPERE PAESAGGISTICHE ET NOTE
PIANTUMAZIONE.
6. SEED ALL AREAS DISTURBED BY CONSTRUCTION UNLESS
OTHERWISE NOTED. /
SEMINARE TUTTE LE AREE ALTERATE DALLA COSTRUZIONE
SALVO DIVERSAMENTE INDICATO
TV
TV
TV
TV
TV
TV
TV
TV
PLAN
NORTH
MATCHLINE - SEE SHEET LP103 FOR CONTINUATION / LINEA DI UNIONE - VEDERE TAVOLA LP103 PER CONTINUARE
MATCHLINE - SEE SHEET LP105 FOR CONTINUATION / LINEA DI UNIONE - VEDERE TAVOLA LP105 PER CONTINUARE
LP104
La st s av ed b y:
J
EN
N
IF
ER
.R
EN
1(
-1
1-
L as t P lo tte d:
1-
-0
Fi le na m e:
N
A.
AE
C O
M N
ET
.C
O M
\L
FS
\A M
ER
\R
O
AN
O
KE
-U
SR
N K1
\D C
S\
PR
O
JE
C
TS
\B D
L\
\9
_C
AD
_G
IS
\9
_C
AD
\2
0-
SH
EE
TS
\L \1
-V
C 3_
LP
1-
LP
5.
D W
G La st s av ed b y:
J
EN
N
IF
ER
.R
EN
1(
-1 1-
L as t P lo tte d:
1-
-0
Fi le na m e:
N A.
AE
C
O M
N
ET
.C O
M \L
FS
\A
M
ER
\R O
AN
O
KE
-U
SR
N
K1 \D
C S\
PR
O
JE
C
TS
\B
D L\
\9
_C
AD
_G
IS
\9
_C
AD
\2 0-
SH
EE
TS
\L
\1
-V C
3_
LP
1-
LP
5.
D
W G
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
AR
M Y
FA
M
IL
Y
HO
US
IN
G
P
RO
JE
CT
DRAWFORM REVISION: 20 AUGUST 2020
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
5m 10m0 25m 1:250
UNLESS OTHERWISE NOTED, LINEAR DIMENSIONS SHOWN ARE IN METERS.
SE NON ALTRIMENTI INDICATO, LE DIMENSIONI LINEARI SONO IN METRI
KEY PLAN
NO SCALEPIANO STRATEGICO
AS NOTED
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
LP104
GENERAL NOTES THIS SHEET: /
NOTE GENERALI DI QUESTO FOGLIO:
EXISTING TREE TO REMAIN /
ALBERO ESISTENTE CHE DEVE RIMANERE
CANOPY TREE /
ALBERO AD OMBRELLO
EVERGREEN TREE /
ALBERO SEMPREVERDE
SMALL CANOPY TREE, ORNAMENTAL TREE /
ALBERO ORNAMENTALE
SHRUB /
CESPUGLIO
PERENNIALS AND GROUNDCOVER /
PIANTE PERENNI E TAPPEZZAMENTI
SEEDED LAWN /
PRATO SEMINATO
SODDED LAWN /
PRATO RIZOLLATO
SODDED GRASS PAVER /
PAVIMENTAZIONE CON ERBA SEMINATA
PLANTING LEGEND: /
LEGENDA PIANTUMAZIONE:
LA
ND
SC
AP
E
PL
AN
TI
NG
P
LA
N
PI
AN
TA
D
I P
IA
NT
UM
AZ
IO
NE
P
AE
SA
GG
IO
1. KEEP PLANTS A MINIMUM OF 0.5 METERS FROM APARTMENT
BUILDINGS. /
TENERSE LE PIANTE MINIMO A 0.5m DAGLI APPARTAMENTI.
2. SEE SHEET C-001 FOR CIVIL NOTES AND LEGENDS. /
VEDERE TAVOLA C-001 PER NOTE CIVILI LA LEGENDA.
3. SEE CIVIL SHEETS FOR ADDITIONAL INFORMATION. /
VEDERE LE TAVOLE CIVILI, PER INFORMAZIONI AGGIUNTIVE.
4. SEE SHEET LP501 FOR TREE SUPPORT SCHEDULE AND LP502
FOR PLANT SPACING DETAIL. /
VEDERE TAVOLA LP501 PER L'ABACO DEL SUPPORTO AGLI
ALBERI E LP502 PER DETAGLI DI SPAZIATURA TRA LE PIANTE.
5. SEE SHEET LP601-LP602 FOR PLANTING SCHEDULE AND
PLANTING NOTES. /
VEDERE TAVOLA LP601-LP602 PER PROGRAMMA
PIANTUMAZIONE OPERE PAESAGGISTICHE ET NOTE
PIANTUMAZIONE.
6. SEED ALL AREAS DISTURBED BY CONSTRUCTION UNLESS
OTHERWISE NOTED. /
COMM COMM COMM COMM COMM COMM
MH-24A
SANSAN
MG
MG
1+220
1+232
150 PE80
PLAN
NORTH
MATCHLINE - SEE SHEET LP104 FOR CONTINUATION / LINEA DI UNIONE - VEDERE TAVOLA LP104 PER CONTINUARE
MA
TC
HL
IN
E
- S
EE
S
HE
ET
LP
2 F
OR
C
ON
TI
NU
AT
IO
N / L
IN
EA
D I U
NI
ON
E
- V
ED
ER
E
TA
VO
LA
LP
2 P
ER
C
ON
TI
NU
AR
E
LP105
La st s av ed b y:
J
EN
N
IF
ER
.R
EN
1(
-1
1-
L as t P lo tte d:
1-
-0
Fi le na m e:
N
A.
AE
C O
M N
ET
.C
O M
\L
FS
\A M
ER
\R
O
AN
O
KE
-U
SR
N K1
\D C
S\
PR
O
JE
C
TS
\B D
L\
\9
_C
AD
_G
IS
\9
_C
AD
\2
0-
SH
EE
TS
\L \1
-V
C 3_
LP
1-
LP
5.
D W
G La st s av ed b y:
J
EN
N
IF
ER
.R
EN
1(
-1 1-
L as t P lo tte d:
1-
-0
Fi le na m e:
N A.
AE
C
O M
N
ET
.C O
M \L
FS
\A
M
ER
\R O
AN
O
KE
-U
SR
N
K1 \D
C S\
PR
O
JE
C
TS
\B
D L\
\9
_C
AD
_G
IS
\9
_C
AD
\2 0-
SH
EE
TS
\L
\1
-V C
3_
LP
1-
LP
5.
D
W G
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
AR
M Y
FA
M
IL
Y
HO
US
IN
G
P
RO
JE
CT
DRAWFORM REVISION: 20 AUGUST 2020
GRAPHIC SCALE
SCALA GRAFICA
NORTH
NORD
5m 10m0 25m 1:250
UNLESS OTHERWISE NOTED, LINEAR DIMENSIONS SHOWN ARE IN METERS.
SE NON ALTRIMENTI INDICATO, LE DIMENSIONI LINEARI SONO IN METRI
KEY PLAN
NO SCALEPIANO STRATEGICO
AS NOTED
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
LP105
LP105
GENERAL NOTES THIS SHEET: /
NOTE GENERALI DI QUESTO FOGLIO:
EXISTING TREE TO REMAIN /
ALBERO ESISTENTE CHE DEVE RIMANERE
CANOPY TREE /
ALBERO AD OMBRELLO
EVERGREEN TREE /
ALBERO SEMPREVERDE
SMALL CANOPY TREE, ORNAMENTAL TREE /
ALBERO ORNAMENTALE
SHRUB /
CESPUGLIO
PERENNIALS AND GROUNDCOVER /
PIANTE PERENNI E TAPPEZZAMENTI
SEEDED LAWN /
PRATO SEMINATO
SODDED LAWN /
PRATO RIZOLLATO
SODDED GRASS PAVER /
PAVIMENTAZIONE CON ERBA SEMINATA
PLANTING LEGEND: /
LEGENDA PIANTUMAZIONE:
LA
ND
SC
AP
E
PL
AN
TI
NG
P
LA
N
PI
AN
TA
D
I P
IA
NT
UM
AZ
IO
NE
P
AE
SA
GG
IO
1. KEEP PLANTS A MINIMUM OF 0.5 METERS FROM APARTMENT
BUILDINGS. /
TENERSE LE PIANTE MINIMO A 0.5m DAGLI APPARTAMENTI.
2. SEE SHEET C-001 FOR CIVIL NOTES AND LEGENDS. /
VEDERE TAVOLA C-001 PER NOTE CIVILI LA LEGENDA.
3. SEE CIVIL SHEETS FOR ADDITIONAL INFORMATION. /
VEDERE LE TAVOLE CIVILI, PER INFORMAZIONI AGGIUNTIVE.
4. SEE SHEET LP501 FOR TREE SUPPORT SCHEDULE AND LP502
FOR PLANT SPACING DETAIL. /
VEDERE TAVOLA LP501 PER L'ABACO DEL SUPPORTO AGLI
ALBERI E LP502 PER DETAGLI DI SPAZIATURA TRA LE PIANTE.
5. SEE SHEET LP601-LP602 FOR PLANTING SCHEDULE AND
PLANTING NOTES. /
VEDERE TAVOLA LP601-LP602 PER PROGRAMMA
PIANTUMAZIONE OPERE PAESAGGISTICHE ET NOTE
PIANTUMAZIONE.
6. SEED ALL AREAS DISTURBED BY CONSTRUCTION UNLESS
OTHERWISE NOTED. /
L a s t s a v e d b y
Z
H I H
A O
L I s t
P l o t t e d
F i l e n a m e
N
A A
E C
O M
N E
T C
O M
L F
S A
M E
R R
O A
N O
K E
U
S R
N K
D
C S
P
R O
J E
C T
S B
D L C
A D
G
I S
C
A D
S
H E
E T
S L V
C L P
L P
D
W G
L a s t s a v e d b y
Z
H I H
A O
L I s t
P l o t t e d
F i l e n a m e
N
A A
E C
O M
N E
T C
O M
L F
S A
M E
R R
O A
N O
K E
U
S R
N K
D
C S
P
R O
J E
C T
S B
D L C
A D
G
I S
C
A D
S
H E
E T
S L V
C L P
L P
D
W G
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
DRAWFORM REVISION: 20 AUGUST 2020
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
AR
M Y
FA
M
IL
Y
HO
US
IN
G
P
RO
JE
CT
AS NOTED
LP501
L A
N D
S C
A P
E
P
L A
N T
I N
G
D
E T
A I L S
D E
T T
A G
L I
P
I A
N T
U M
A Z
I O
N E
P
A E
S A
G G
I O
UNLESS OTHERWISE NOTED, LINEAR DIMENSIONS SHOWN ARE IN MILLIMETERS. /
SE NON ALTRIMENTI INDICATO, LE DIMENSIONI LINEARI SONO IN MILLIMETRI.
B1
A1 A3 A4
B3
TREE PLANTING, GUYING - PIANTUMAZIONE
PLAN / PIANTA
M
I
N
FINISH GRADE /
PIANO FINITO
PLANTING SOIL MIX /
MIX TERRENO VEGETALE
SCARIFY EXCAVATION /
SCARIFICA
32.41
75MM OR LARGER CALIPER TREE /
CALIBRO PER ALBERO 75 MM O
PIÙ GRANDE
32.47
32.49
32.40
32.48
32.42
32.43
32.44
32.45
32.46
32.52
B2
LP101 SCALE:
DI ALBERI, STABILIZZAZIONE DEGLI ALBERI
NOT TO SCALE / NON IN SCALA
32.50
2400-3600mm
TREE HEIGHT /
ALTEZZA
ALBERO
TREE CALIPER /
CALIBRO ALBERO
SUPPORT
SYSTEM /
SISTEMA DI
SUPPORTO
WEBBED TIE
OR CABLE /
FASCETTA O CAVO
TURNBUCKLE /
TENDITORE
HOSE /
TUBO
QUAN-
TITY/
QUAN-
TITÀ
2100mm
UPRIGHT
STAKE /
PALO
VERTICALE
WOVEN
POLYPROPYLENE TIE /
CAVI IN
POLIPROPILENE
INTRECCIATO
--LESS THAN
75mm /
MENO DI
GUY /
TIRANTE
75mm AND UP /
E SU
6000mm
AND OVER /
E SOPRA
DEADMAN /
SISTEMA DI
ANCORAGGIO
DEADMAN
150mm AND UP /
E SU
100mm AND UP /
E SU
3*
4.8mm CABLE* /
CAVO 4.8MM
9.5mm X 150mm*
* OR AS APPROPRIATE / O COME APPROPRIATO
19mm
3600-4200mm
4200-6000mm
WOVEN
POLYPROPYLENE TIE /
CAVI IN
POLIPROPILENE
INTRECCIATO
WOVEN
POLYPROPYLENE TIE /
CAVI IN
POLIPROPILENE
INTRECCIATO
TREE SUPPORT SCHEDULE -
-- --GUY /
TIRANTE
D5
LP101 SCALE:
PIANO DI SUPPORTO DELL'ALBERO
NOT TO SCALE / NON IN SCALA
FINISH GRADE /
PIANO FINITO
PLANTING SOIL MIX /
MIX TERRENO VEGETALE
PLAN / PIANTA
SCARIFY EXCAVATION /
SCARIFICA
MULTI-STEM TREE PLANTING -
32.41
M
N
32.42
32.43
32.44
32.45
32.46
32.47
32.49
32.48
32.40
32.52
A1
LP101 SCALE:
PIANTUMAZIONE DI ALBERI MULTI-FUSTO
NOT TO SCALE / NON IN SCALA
32.50
SHRUB PLANTING -
PLANTING SOIL MIX AND PLANTING BED
CONTINUOUS BETWEEN PLANTS /
TERRENO MISTO DI TERRA VEGETALE E LETTO
DI PIANTAGIONE CONTINUO TRA PIANTE
75MM MULCH, FORM INTO SAUCER AROUND EACH PLANT /
75MM PACCIAME, CREARE UN DISCO ATTORNO AD OGNI PIANTA
SCARIFY EXCAVATION / SCARIFICA
FINISH GRADE / PIANO FINITO
C1
LP101 SCALE:
PIANTUMAZIONE ARBUSTI
NOT TO SCALE / NON IN SCALA
SHEET KEYNOTES: /
NOTE CHIAVE DI QUESTO FOGLIO:
32.40 1/8 DEPTH ROOT BALL MAXIUMUM. /
MASSIMO 1/8 DI PROFONDITÀ DEL BULBO RADICALE.
32.41 3X ROOT BALL WIDTH. /
3X LARGHEZZA DEL BULBO RADICALE.
32.42 TREE SUPPORT SYSTEM (3) GUYING STAKES WITH WIDE SOFT WOVEN POLYPROPYLENE TIES. USE
SECURED SLIPKNOT TO FORM LOOP 150-200MM Ø LARGER THAN TRUNK. SECURE TREE BUT ALLOW FOR
SLIGHT MOVEMENT. /
SISTEMA DI SOSTEGNO DELL'ALBERO (3) PALI DI TIRAGGIO CON LARGHE FASCETTE IN POLIPROPILENE MORBIDO INTRECCIATO. UTILIZZARE CAPPI SICURI PER FORMARE UN'ANSA DI 150-200 MM Ø PIÙ GRANDE DEL TRONCO. FISSARE L'ALBERO IN MODO SICURO MA CONSENTIRE UN LEGGERO MOVIMENTO.
32.43 SET TRUNK FLARE ABOVE SURROUNDING FINISH GRADE. DO NOT COVER WITH SOIL. /
IMPOSTARE IL CEPPO AL DI SOPRA DEL LIVELLO DI RIFINITURA CIRCOSTANTE. NON COPRIRE CON
TERRENO.
32.44 75MM MULCH, DO NOT COVER TRUNK FLARE. /
75MM PACCIAME, NON COPRIRE IL PIEDE DEL TRONCO.
32.45 AFTER POSITIONING TREE, PARTIALLY BACKFILL TO SUPPORT ROOT BALL SHAPE AND REMOVE ALL TREATED OR SYNTHETIC BURLAP, WIRE BASKET, ROPE, TWINE, AND TOP THIRD OF NATURAL BURLAP
FROM FIRM ROOT BALL. /
DOPO AVER POSIZIONATO L'ALBERO, RIEMPIRE PARZIALMENTE IL TERRENO PER SOSTENERE LA FORMA DELLA ZOLLA DI RADICE E RIMUOVERE TUTTA LA IUTA TRATTATA O SINTETICA, IL CESTINO DI FILO, LA CORDA, LO SPAGO E IL TERZO SUPERIORE DELLA IUTA NATURALE DALLA PALLA DI RADICE SOLIDA.
32.46 PROVIDE 75-100MM HEIGHT SAUCER BEYOND EDGE OF ROOT BALL. /
FORNIRE PIATTINO DI ALTEZZA 75-100MM OLTRE IL BORDO DELLA ZOLLA DELLA RADICE.
32.47 SURVEYOR'S FLAG, AS NECESSARY. /
BANDIERINA DI SEGNALAZIONE, SE NECESSARIO.
32.48 NOTE: FLAGGING IS ENCOURAGED NEAR PEDESTRIAN AREAS, PAVED OR UNPAVED. OBTAIN
CONTRACTING OFFICER’S APPROVAL FOR FLAGGING LOCATIONS. /
NOTA: È INCORAGGIATA LA SEGNALAZIONE IN PROSSIMITÀ DI AREE PEDONALI, PAVIMENTATE O NON PAVIMENTATE. OTTENERE L'APPROVAZIONE DI RESPONSABILE DELLA UFFICIO CONTRAENTE' PER LE AREE
DI SEGNALAZIONE.
32.49 STAKE IN UNDISTURBED SOIL. /
INFIGGERE IN TERRENO INDISTURBATO, 200 MM MINIMO OLTRE LO SCAVO.
32.50 INSTALL ROOT BARRIER AT TREES PER DETAIL A4 ON SHEET LS504. /
INSTALLARE LE BARRIERE PER LE RADICI IN PROSSIMITÁ DEGLI ALBERI COME DETTAGLIATO NELLA
TAVOLA LS504
32.52 TRIM ALL TREE BRANCHES THAT FALL WITHIN PLAY EQUIPMENT USE ZONES TO BE AT LEAST 84 INCHES (2130MM) ABOVE THE UNDERLYING DESIGNATED PLAY SURFACE AND THE PIVOT POINT OF A SWING. / TAGLIARE TUTTI I RAMI DEGLI ALBERI CHE CADONO ALL'INTERNO DELLE ZONE DI UTILIZZO DELLE ATTREZZATURE DI GIOCO PER ESSERE ALMENO 84 POLLICI (2130 MM) SOPRA LA SUPERFICIE DI GIOCO
SOTTOSTANTE DESIGNATA E IL PUNTO DI ROTAZIONE DI UN'ALTALENA.
EVERGREEN TREE PLANTING -
TAMP SOIL AROUND ROOT
BALL TO STABILIZE TREE /
TERRICCIO ATTORNO AL
BULBO RADICALE PER
STABILIZZARE L'ALBERO
FINISH GRADE /
PIANO FINITO
PLANTING SOIL MIX /
MIX TERRENO VEGETALE
SCARIFY EXCAVATION /
SCARIFICA
32.41
32.43
32.44
32.45
32.46
32.40
LP101 SCALE:
PIANTUMAZIONE ALBERI SEMPREVERDI
NOT TO SCALE / NON IN SCALA
32.52
32.50 s t s a v e d b y
Z
H I H
A O
L I s t
P l o t t e d
F i l e n a m e
N
A A
E C
O M
N E
T C
O M
L F
S A
M E
R R
O A
N O
K E
U
S R
N K
D
C S
P
R O
J E
C T
S B
D L C
A D
G
I S
C
A D
S
H E
E T
S L V
C L P
L P
D
W G
L a s t s a v e d b y
Z
H I H
A O
L I s t
P l o t t e d
F i l e n a m e
N
A A
E C
O M
N E
T C
O M
L F
S A
M E
R R
O A
N O
K E
U
S R
N K
D
C S
P
R O
J E
C T
S B
D L C
A D
G
I S
C
A D
S
H E
E T
S L V
C L P
L P
D
W G
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
DRAWFORM REVISION: 20 AUGUST 2020
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
AR
M Y
FA
M
IL
Y
HO
US
IN
G
P
RO
JE
CT
AS NOTED
LP502
UNLESS OTHERWISE NOTED, LINEAR DIMENSIONS SHOWN ARE IN MILLIMETERS. /
SE NON ALTRIMENTI INDICATO, LE DIMENSIONI LINEARI SONO IN MILLIMETRI.
A4
C4
L A
N D
S C
A P
E
P
L A
N T
I N
G
D
E T
A I L S
D E
T T
A G
L I
P
I A
N T
U M
A Z
I O
E
S A
G G
I O
600mm O.C.
900mm O.C. 650mm O.C.
400mm O.C.
ROW "A" /
RIGA 'A
PLANT SPACING "D" /
SPAZIATURA IMPIANTO 'D'
300mm O.C. 250mm O.C.
PLANT, TYPICAL /
PIANTA, TIPICO
D
"D"
D
A
NOTES / NOTA:
1. INSTALL PLANTS WITH
TRIANGULAR SPACING
UNLESS OTHERWISE NOTED /
INSTALLRE LE PIANTE CON
SPAZIATURA TRIANGOLARE A
MENO DI ALTRE NOTE SUI
DISEGNI
2. O.C. = ON CENTER /
O.C. = AL CENTRO
325mm O.C.
400mm O.C.
375mm O.C.
450mm O.C.
250mm O.C.
200mm O.C.
150mm O.C.
175mm O.C.
225mm O.C.
125mm O.C.
PLANT SPACING -
D5
LP101 SCALE:
DISTANZA TRA LE PIANTE
NOT TO SCALE / NON IN SCALA
SET PLANTS IN STAGGERED ROWS AT
SPECIFIED SPACING UNLESS
OTHERWISE INDICATED ON DRAWINGS /
INSTALALRE LE PIANTE IN FILE SFALSATE
A DISTANZE DEFINITE A MENO DI ALTRE
INDICAZIONI SUI DISEGNI
75MM MULCH OVER ENTIRE BED. DO NOT
COVER CROWNS OF PLANTS /
75MM PACCIAME SOPRA L'INTERO LETTO.
NON COPRIRE LE CORONE DELLE PIANTE
PLANTING SOIL MIX AND PLANTING BED
CONTINUOUS BETWEEN PLANTS /
TERRENO MISTO CONTINUO TRA PIANTE
SCARIFY EXCAVATION /
SCARIFICAZIONE
M
I N
C1
LP101 SCALE:
RITOMBAMENTO
NOT TO SCALE / NON IN SCALA
GROUNDCOVER PLANTING -
s t s a v e d b y
M
U E
L L E
R K s t
P l o t t e d
F i l e n a m e
N
A A
E C
O M
N E
T C
O M
L F
S A
M E
R R
O A
N O
K E
U
S R
N K
D
C S
P
R O
J E
C T
S B
D L C
A D
G
I S
C
A D
S
H E
E T
S L V
C L P
L P
D
W G
L a s t s a v e d b y
M
U E
L L E
R K s t
P l o t t e d
F i l e n a m e
N
A A
E C
O M
N E
T C
O M
L F
S A
M E
R R
O A
N O
K E
U
S R
N K
D
C S
P
R O
J E
C T
S B
D L C
A D
G
I S
C
A D
S
H E
E T
S L V
C L P
L P
D
W G
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
DRAWFORM REVISION: 20 AUGUST 2020
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
AR
M Y
FA
M
IL
Y
HO
US
IN
G
P
RO
JE
CT
AS NOTED
LP601
L A
N D
S C
A P
E
P
L A
N T
I N
G
S
C H
E D
U L E
T A
B E
L
A
N T
U M
A Z
I O
E
S A
G G
I O
PLANTING SCHEDULE: /
TABELLA PIANTUMAZIONE:
TREE REPLACEMENT SCHEDULE: /
TABELLA SOSTITUZIONE ALBERO:
SUMMARY OF REQUIREMENTS FOR TREE REPLACEMENT STANDARDS / RIEPILOGO DEI REQUISITI DELLE NORME PER LA SOSTITUZIONE ALBERO:
TREES TO BE REMOVED ≤ 10 CM DBH: 0 / ALBERO DA RIMUOVERE ≤ 10 CM DIAMETRO: 0
REPLACEMENT TREES REQUIRED: 0 / SOSTITUZIONE ALBERI RICHIESTA: 0
REPLACEMENT TREES PROVIDED: 96 (5CM DIAMETER TREES) / SOSTITUZIONE ALBERI PREVISTA: 96 (5CM DIAMETRO TREES)
TREES TO BE REMOVED = 11-20 CM DBH: 5 / ALBERI DA RIMUOVERE = 11-20 CM DIAMETRO: 5
REPLACEMENT TREES REQUIRED: 5 / SOSTITUZIONE ALBERI RICHIESTA: 5
REPLACEMENT TREES PROVIDED: 6 (10-12CM DIAMETER TREES) / SOSTITUZIONE ALBERI PREVISTA: 6 (10-12CM DIAMETRO TREES)
TREES TO BE REMOVED = 21-30 CM DBH: 26 / ALBERI DA RIMUOVERE = 21-30 CM DIAMETRO: 26
REPLACEMENT TREES REQUIRED: 26 / SOSTITUZIONE ALBERI RICHIESTA: 26
REPLACEMENT TREES PROVIDED: 26 (14-16CM DIAMETER TREES) / SOSTITUZIONE ALBERI PREVISTA: 26 (14-16CM DIAMETRO TREES)
TREES TO BE REMOVED ≥31 CM DBH: 91 / ALBERI DA RIMUOVERE ≥31 CM DIAMETRO: 91
REPLACEMENT TREES REQUIRED: 91 / SOSTITUZIONE ALBERI RICHIESTA: 91
REPLACEMENT TREES PROVIDED: 91 (20-22CM DIAMETER TREES) / SOSTITUZIONE ALBERI PREVISTA: 91 (20-22CM DIAMETRO TREES)
CALCULATION OF THE REQUIRED REPLACEMENT TREES / CALCOLO DELA RICHIESTA DI SOSTITUZIONE ALBERI:
1. DBH = TREE DIAMETER TO BE MEASURED AT A 1.3M HEIGHT FROM THE GROUND. /
DBH = DIAMETRO DELL'ALBERO MISURATO A 1.3M DI ALTEZZA DAL TERRENO.
2. PER THE MUNICIPALITY OF VICENZA BUILDING REGULATIONS, ANY TREE THAT IS REMOVED DURING CONSTRUCTION IS REQUIRED TO BE REPLACED BY A NEW TREE
WITH A TRUNK SIZE NO LESS THAN HALF OF THE TREE BEING REPLACED OR ALTERNATIVELY WITH A TREE NO LESS THAN 20 CM DIAMETER IN TRUNK SIZE. /
SECONDO IL REGOLAMENTO EDILIZIO DEL COMUNE DI VICENZA, QUALSIASI ALBERO TAGLIATO IN COSTRUZIONE DEVE ESSERE SOSTITUITO DA UN ALBERO NUOVO CON
TRONCO DI DIMENSIONI NON INFERIORI ALLA METÀ
DELL'ALBERO
DA SOSTITUIRE O IN ALTERNATIVA CON UN ALBERO CON TRONCO DI DIAMETRO NON MINORE DI 20 CM.
s t s a v e d b y
J E
N N
I F
E R
R
E N s t
P l o t t e d
F i l e n a m e
N
A A
E C
O M
N E
T C
O M
L F
S A
M E
R R
O A
N O
K E
U
S R
N K
D
C S
P
R O
J E
C T
S B
D L C
A D
G
I S
C
A D
S
H E
E T
S L V
C L P
L P
D
W G
L a s t s a v e d b y
J E
N N
I F
E R
R
E N s t
P l o t t e d
F i l e n a m e
N
A A
E C
O M
N E
T C
O M
L F
S A
M E
R R
O A
N O
K E
U
S R
N K
D
C S
P
R O
J E
C T
S B
D L C
A D
G
I S
C
A D
S
H E
E T
S L V
C L P
L P
D
W G
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
DRAWFORM REVISION: 20 AUGUST 2020
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
AR
M Y
FA
M
IL
Y
HO
US
IN
G
P
RO
JE
CT
AS NOTED
LP602
L A
N D
S C
A P
E
P
L A
N T
I N
G
N
O T
E S
N O
T
A
N T
U M
A Z
I O
E
S A
G G
I O
PLANTING NOTES: /
NOTE PIANTUMAZIONE:
1. PLANT MATERIAL SHALL BE FURNISHED AND INSTALLED AS INDICATED, INCLUDING ALL LABOR, MATERIALS, PLANTS, EQUIPMENT, INCIDENTALS, AND CLEAN-UP. /
IL MATERIALE PER LA PIANTUMAZIONE DOVRA' ESSERE FORNITO ED INSTALLATO COME INDICATO, INCLUSA LA MANODOPERA, MATERIALI, PIANTE, ATTREZZATURE, IMPREVISTI E LA
PULIZIA FINALE.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PLANTING AT CORRECT GRADES AND ALIGNMENT. LAYOUT TO BE APPROVED BY CONTRACTING OFFICER PRIOR TO INSTALLATION. /
L'IMPRESA DOVRA' ESSERE RESPONSABILE DELLA PIANTUMAZIONE ALLE QUOTE, ALLINEAMENTI E LIVELLI DI FINITURA CORRETTI CHE DOVRANNO ESSERE APPROVATI
DALL'UFFICIALE CONTRAENTE PRIMA DELL'INSTALLAZIONE.
3. CONTRACTOR SHALL FIELD VERIFY ALL UTILITY LOCATIONS PRIOR TO COMMENCEMENT OF WORK. DO NOT PLANT DIRECTLY OVER UTILITY LINES. CONTRACTOR SHALL BE
RESPONSIBLE FOR DAMAGE RESULTING FROM FAILURE TO PROPERLY LOCATE AND PROTECT UTILITIES. /
L'IMPRESA DOVRA' VERIFICARE IN CAMPO LA POSIZIONE DI TUTTI I SERVIZI INTERRATI PRIMA DELL'INIZIO DEI LAVORI. NON PIANTARE DIRETTAMENTE SOPRA I SERVIZI INTERRATI;
L'IMPRESA SARA' RESPONSABILE PER DANNI DERIVANTI DALLA NON PROTEZIONE DELLE LINEE SERVIZI INTERRATI.
4. THE PLANT QUANTITIES SHOWN ARE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL QUANTITIES AND REPORTING ANY
DISCREPANCIES TO THE CONTRACTING OFFICER FOR CLARIFICATION PRIOR TO THE CONTRACT AWARD AND COMMENCEMENT OF WORK. /
LE QUANTITA' DELLE PIANTE INDICATE SONO A FAVORE DELL'IMPRESA. L'IMPRESA DEVE VERIFICARE LE QUANTITA' E DEVE RIPORTARE OGNI DISCREPANZA ALL'UFFICIALE
CONTRAENTE E CHIEDERE CHIARIMENTI PRIMA DELL'AGGIUDICAZIONE E DI INIZIARE I LAVORI.
5. PRIOR TO PLANTING INSTALLATION, THE CONTRACTOR SHALL CONFIRM THE AVAILABILITY OF ALL THE SPECIFIED PLANT MATERIALS. SUBMIT DATED PHOTOGRAPHS WITH SCALE
REFERENCE, OF ALL TREE MATERIALS AND SPECIMEN MATERIAL TO THE CONTRACTING OFFICER FOR APPROVAL PRIOR TO ORDERING. /
PRIMA DELLA PIANTUMAZIONE, L'IMPRESA DOVRA' CONFERMARE LA DISPONIBILITA' DI TUTTI I MATERIALI VEGETALI SPECIFICATI. SOTTOMETTERE ALL'UFFICIALE CONTRAENTE
FOTOGRAFIE DATATE E CON RIFERIMENTO IN SCALA E UN CAMPIONE DI TUTTI I MATERIALI.
6. ALL PLANT MATERIAL SIZES SPECIFIED ARE MINIMUM SIZES. CONTAINER SIZE SHALL BE INCREASED IF NECESSARY TO PROVIDE OVERALL PLANT SIZE SPECIFIED. /
TUTTE LE TAGLIE DEI MATERIALI DELLA PIANTUMAZIONE SONO QUELLE MINIME. LA DIMENSIONE DEI CONTAINER DOVRA' ESSERE AUMENTATA IN MODO DA CONTENERE LA
GRANDEZZA TOTALE DELLA PIANTA.
7. CONTRACTOR SHALL LEAVE NO HOLES OPEN OVERNIGHT. IF PLANTS CANNOT BE PLANTED IN HOLES DUG, THE HOLES SHALL BE BACKFILLED OR SUITABLY COVERED. /
L'IMPRESA NON DOVRA' LASCIARE BUCHE APERTE DURANTE LA NOTTE. SE GLI ALBERI NON POTRANNO ESSERE PIANTATI IN BUCHE SCAVATE, LE BUCHE DOVRANNO ESSERE
RIEMPITI OD OPPORTUNAMENTE COPERTE.
8. PLANTS SHALL BE TYPICAL OF THEIR SPECIES AND VARIETY; HAVE NORMAL GROWTH HABITS, WELL-DEVELOPED DENSELY FOLIATED BRANCHES, AND VIGOROUS ROOT SYSTEMS;
AND BE FREE FROM DEFECTS, INJURIES, WEEDS, AND INSECT PESTS. QUALITY AND SIZE OF PLANTS, SPREAD OF ROOTS, AND SIZE OF ROOTBALL SHALL BE IN ACCORDANCE WITH
THE MOST RECENT VERSION OF ANSI Z60.1 "AMERICAN STANDARD FOR NURSERY STOCK" PUBLISHED BY THE AMERICAN ASSOCIATION OF NURSERYMEN, INC. /
LE PIANTE DOVRANNO ESSERE TIPICHE NELLE LORO SPECIE E VARIETA'; DOVRANNO AVERE ABITUDINI NORMALI DI CRESCITA, RAMI BEN SVILUPPATI DENSAMENTE FOLIATI E RADICI
VIGOROSE; ED ESSERE ESENTI DA DIFETTI, LESIONI, ERBACCE E INSETTI NOCOVI. QUALITÀ E DIMENSIONI DELLE PIANTE, ESPANSIONE DELLE RADICI E LE DIMENSIONI DELLE ZOLLE
DEVONO ESSERE CONFORMI ALLA VERSIONE PIÙ RECENTE DI ANSI Z60.1 "STANDARD AMERICANO PER STOCK DI VIVAIO" PUBBLICATO DALL'ASSOCIAZIONE AMERICANA DI
NURSERYMEN, INC.
9. ALL PLANT MATERIAL SHALL BE GUARANTEED BY THE CONTRACTOR TO BE IN VIGOROUS GROWING CONDITION. PROVISION SHALL BE MADE FOR A GROWTH GUARANTEE OF AT
LEAST ONE YEAR FROM THE DATE OF ACCEPTANCE FOR TREES AND SHRUBS. REPLACEMENTS SHALL BE MADE AT THE BEGINNING OF THE FIRST FOLLOWING PLANTING SEASON.
ALL REPLACEMENTS SHALL HAVE A GUARANTEE EQUAL TO THAT STATED ABOVE. /
TUTTE LE PIANTE DOVRANNO ESSERE GARANTITE DALL'IMPRESA PER AVERE UNA CONDIZIONE DI CRESCITA VIGOROSA. LA FORNITURA DEVE ESSERE EFFETTUATA PER UNA
GARANZIA DI CRESCITA DI ALMENO UN ANNO DALLA DATA DI ACCETTAZIONE DEGLI ALBERI E DEGLI ARBUSTI. LE SOSTITUZIONI DEVONO ESSERE EFFETTUATE ALL'INIZIO DELLA
PRIMA STAGIONE ADATTA ALLA PIANTUMAZIONE. LE SOSTITUZIONI DEVONO ESSERE EFFETTUATE ALL'INIZIO DELLA PRIMA STAGIONE DI SEMINA.TUTTE LE SOSTITUZIONI DOVRANNO
AVERE UNA GARANZIA PARI A QUESTA SOPRA CITATA.
10. PLANT MATERIAL SHALL BE PLANTED ON THE DAY OF DELIVERY IF/WHEN PRACTICAL. IN THE EVENT THAT THIS IS NOT POSSIBLE, THE CONTRACTOR SHALL PROTECT STOCK NOT
PLANTED. PLANTS SHALL NOT REMAIN UNPLANTED FOR LONGER THAN A THREE-DAY PERIOD AFTER DELIVERY. ANY PLANTS NOT INSTALLED DURING THIS PERIOD SHALL BE
REJECTED. /
IL MATERIALE DELLA PIANTUMAZIONE DEVE ESSERE IMPIANTATO IL GIORNO STESSO DELLA CONSEGNA SE / QUANDO PRATICABILE. NEL CASO IN CUI NON È POSSIBILE, L'APPALTATORE PROTEGGERA' LO STOCK NON IMPIANTATO. LE PIANTE NON DEVONO RIMANERE IMPIANTATE PER UN PERIODO SUPERIORE A TRE GIORNI DOPO LA CONSEGNA. OGNI
PIANTA NON INSTALLATA DURANTE QUESTO PERIODO DEVE ESSERE RESPINTO.
11. ALL PLANTS SHALL BE PLANTED IN AMENDED TOP SOIL THAT IS THOROUGHLY WATERED AND TAMPED AS BACK-FILLING PROGRESSES. LARGE PLANTING AREAS TO INCORPORATE
FERTILIZER AND SOIL CONDITIONERS AS STATED IN PLANTING SPECIFICATIONS. CONTRACTOR SHALL BEAR ALL COSTS OF TESTING OF SOILS, AMENDMENTS, ETC. ASSOCIATED
WITH THE WORK. SEE SPECIFICATIONS FOR ADDITIONAL TESTING REQUIREMENTS. /
TUTTE LE PIANTE DEVONO ESSERE PIANTATE IN UN TERRENO VEGETALE SUPERIORE CONCIMATO CHE È COMPLETAMENTE UMIDIFICATO E COMPATTATO DURANTE IL RIEMPIMENTO.
CI DEVONO ESSERE AMPIE AREE PER LA PIANTUMAZIONE PER INCORPORARE CONCIMI E AMMENDANTI DEL SUOLO IN BASE ALLE SPECIFICHE DI PIANTUMAZIONE. L'APPALTATORE
DOVRA' ACCOLLARSI TUTTI I COSTI DI PROVA DI SUOLI, MODIFICHE, ECC. ASSOCIATO AL LAVORO. VEDI SPECIFICHE PER I REQUISITI DI PROVA AGGIUNTIVI
12. PLANTS SHALL NOT BE BOUND WITH WIRE OR ROPE AT ANY TIME SO AS TO DAMAGE THE BARK OR BREAK BRANCHES. PLANTS SHALL BE HANDLED FROM THE BOTTOM OF THE BALL
ONLY. /
LE PIANTE NON DEVONO ESSERE FISSATE CON CAVO O CORDA IN QUALSIASI MOMENTO, IN MODO DA DANNEGGIARE LA CORTECCIA O ROMPERE I RAMI. LE PIANTE DEVONO ESSERE
MANEGGIATE SOLO DALLE ZOLLE
13. PLANTING OPERATIONS SHALL BE PERFORMED DURING PERIODS WITHIN THE PLANTING SEASON WHEN WEATHER AND SOIL CONDITIONS ARE SUITABLE AND IN ACCORDANCE WITH
ACCEPTED LOCAL PRACTICE. PLANTS SHALL NOT BE INSTALLED IN TOP SOIL THAT IS IN A MUDDY CONDITION. /
LE OPERAZIONI DI PIANTUMAZIONE DEVONO ESSERE EFFETTUATE DURANTE I PERIODI NELL'AMBITO DELLA STAGIONE INDICATA DI PIANTUMAZIONE QUANDO LE CONDIZIONI
METEREOLOGICHE E DEL SUOLO SONO IDONEE E SECONDO LA PRATICA LOCALE ACCETTATA. LE PIANTE NON DEVONO ESSERE INSTALLATE IN TERRENI IN CONDIZIONE FANGOSA
14. NO PLANTS, SHALL BE PLANTED LESS THAN FOURTY SIX CENTIMETERS FROM EXISTING STRUCTURES AND SIDEWALKS. /
NESSUNA PIANTA, DEVE ESSERE IMPIANTO A MENO DI QUARANTASEI CENTIMETRI DA STRUTTURE ESISTENTI E MARCIAPIEDI.
15. ALL PLANTING BEDS SHALL BE MULCHED WITH 75MM LAYER OF DOUBLE SHREDDED HARDWOOD BARK MULCH. /
TUTTI I LETTI DI SEMINA DEVONO ESSERE PACCIAMATI CON UNO STRATO DI 75 MM DI CORTECCIA DI LEGNO DURO DOPPIAMENTE TRITURATO.
16. SET ALL PLANTS PLUMB AND STRAIGHT. SET AT SUCH LEVEL THAT A NORMAL OR NATURAL RELATIONSHIP TO THE GROUND SURFACE WILL BE ESTABLISHED. LOCATE THE PLANT IN
THE CENTER OF THE PIT. CONTRACTOR SHALL BE RESPONSIBLE FOR STABILITY AND PLUMB CONDITION OF ALL TREES AND SHRUBS AND SHALL BE LEGALLY VIABLE FOR ANY
DAMAGE CAUSED BY INSTABILITY OF ANY PLANT MATERIALS. /
IMPOSTARE TUTTE LE PIANTE A PIOMBO E DRITTE. IMPOSTARE AD UN LIVELLO TALE DA STABILIRE UN RAPPORTO NORMALE O NATURALE CON LA SUPERFICIE DEL TERRENO.
LOCALIZZARE LA PIANTA AL CENTRO DEL POZZETTO. L'APPALTATORE È RESPONSABILE DELLA STABILITÀ E DELLA MESSA A PIOMBO DI TUTTI GLI ALBERI E ARBUSTI E DEVE ESSERE
LEGALMENTE RINTRACCIABILE PER QUALSIASI DANNO CAUSATO DALL'INSTABILITÀ DI QUALSIASI MATERIALE VEGETALE.
17. ALL INJURED ROOTS SHALL BE PRUNED TO MAKE CLEAN ENDS BEFORE PLANTING UTILIZING CLEAN, SHARP TOOLS. PRUNE DEAD, DISEASED OR DAMAGED TISSUE FROM ALL
PLANTS. MAIN LEADER OF TREES SHALL NOT BE CUT BACK. CARE SHALL BE TAKEN TO PRESERVE EXISTING TREES AND ROOT SYSTEMS. EXISTING TREES INCURRING ROOT DAMAGE
DUE TO CONSTRUCTION SHALL BE PRUNED WITH CLEAN, SHARP TOOLS. /
TUTTE LE RADICI DANNEGGIATE DEVONO ESSERE POTATE IN MODO DA OTTENERE ESTREMITÀ PULITE PRIMA DI ESSERE PIANTATE UTILIZZANDO ATTREZZI PULITI E AFFILATI. POTARE
I TRATTI MORTI, MALATI O DANNEGGIATI DI TUTTE LE PIANTE. I RAMI PRINCIPALI DEGLI ALBERI NON DEVONO ESSERE TAGLIATI. OCCORRE PRESTARE ATTENZIONE A PRESERVARE
GLI ALBERI E LE RADICI ESISTENTI. GLI ALBERI ESISTENTI CHE SUBISCONO DANNI ALLE RADICI A CAUSA DELLA COSTRUZIONE DEVONO ESSERE POTATI CON ATTREZZI PULITI E
AFFILATI.
18. CONTRACTOR SHALL REGRADE ALL AREAS DISTURBED BY PLANT REMOVAL, RELOCATION, AND/OR INSTALLATION WORK. ALL PLANTING BEDS SHALL BE MULCHED PER THE
SPECIFICATIONS. /
L'APPALTATORE È TENUTO A MODIFICARE LA PENDENZA DI TUTTE LE AREE DISTURBATE DALLA RIMOZIONE DELLE PIANTE, DAL TRASFERIMENTO E/O DAI LAVORI DI INSTALLAZIONE.
TUTTE LE AIUOLE DEVONO ESSERE PACCIAMATE SECONDO LE SPECIFICHE.
19. ALL PLANTING AREAS SHALL BE ADEQUATELY WATERED TO ESTABLISH THE PROPOSED PLANTS. /
TUTTE LE AREE DI PIANTUMAZIONE DEVONO ESSERE ADEGUATAMENTE INNAFFIATE PER CONSENTIRE L'INSEDIAMENTO DELLE PIANTE PROPOSTE
20. ALL PLANTS SHOWN ON THE APPROVED LANDSCAPE PLAN SHALL BE INSPECTED AND APPROVED BY THE CONTRACTING OFFICER. THE CONTRACTING OFFICER SHALL TAKE INTO
ACCOUNT SEASONAL CONSIDERATIONS IN THIS REGARD. /
TUTTI GLI INSTALLAZIONI CHE FIGURANO SUL PIANO PAESAGGISTICO APPROVATO DEVONO ESSERE ISPEZIONATI E APPROVATI DALL'AGENTE CONTRATTUALE. L'AGENTE
CONTRATTUALE TIENE CONTO DI CONSIDERAZIONI STAGIONALI AL RIGUARDO.
21. FINAL LOCATION FOR PLANT MATERIAL AND PLANTING BEDS SHALL BE SUBJECT TO THE CONTRACTING OFFICER'S APPROVAL. CONTRACTOR SHALL OBTAIN APPROVAL FOR
LOCATIONS PRIOR TO DIGGING OR INSTALLATION. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER 72 HOURS PRIOR TO DELIVERY AND INSTALLATION OF LANDSCAPE
PLANTS, SO THAT THEY MAY BE ON SITE TO INSPECT PLANT MATERIAL AND VIEW INSTALLATION. /
L'UBICAZIONE DEFINITIVA DEL MATERIALE VEGETALE E DEI LETTI DI IMPIANTO È SOGGETTA ALL'APPROVAZIONE ALL'UFFICIALE CONTRAENTE. L'APPALTATORE DEVE OTTENERE
L'APPROVAZIONE DEI SITI PRIMA DELLO SCAVO O DELL'INSTALLAZIONE. IL CONTRAENTE DEVE NOTIFICARE UFFICIALE CONTRAENTE 72 ORE PRIMA DELLA CONSEGNA E
DELL'INSTALLAZIONE DELLE PIANTE DA PAESAGGIO, IN MODO CHE POSSANO ESSERE SUL POSTO PER ISPEZIONARE IL MATERIALE VEGETALE E VISIONARE L'INSTALLAZIONE.
22. MAINTENANCE SHALL BEGIN AFTER EACH PLANT HAS BEEN INSTALLED AND SHALL CONTINUE UNTIL THE PROJECT HAS BEEN DEEMED SUBSTANTIALLY COMPLETE. MAINTENANCE
INCLUDES WATERING, PRUNING, WEEDING, MULCHING, REPLACEMENTS OF SICK OR DEAD PLANTS, AND ANY OTHER CARE NECESSARY FOR THE PROPER GROWTH OF THE PLANT
MATERIALS. /
LA MANUTENZIONE INIZIA DOPO L'INSTALLAZIONE DI CIASCUNA PIANTA E PROSEGUE FINO A QUANDO IL PROGETTO NON SIA STATO RITENUTO SOSTANZIALMENTE COMPLETO. LA
MANUTENZIONE COMPRENDE L'IRRIGAZIONE, LA POTATURA, IL DISERBO, LA PACCIAMATURA, LA SOSTITUZIONE DI PIANTE MALATE O MORTE E QUALSIASI ALTRA CURA NECESSARIA
PER LA CORRETTA CRESCITA DEI MATERIALI VEGETALI.
23. CONTRACTOR SHALL SUBMIT WRITTEN GUARANTEE OF SURVIVABILITY OF ALL PLANT MATERIALS FOR A PERIOD OF ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION. /
L'APPALTATORE DEVE PRESENTARE UNA GARANZIA SCRITTA DI SOPRAVVIVENZA DI TUTTE LE PIANTE PER UN PERIODO DI UN ANNO DALLA DATA DI COMPLETAMENTO SOSTANZIALE.
24. ALL DISTURBED AREAS (AND OTHER AREAS ON SITE WHERE GRASS IS NOT ESTABLISHED) SHALL BE TREATED WITH 100MM TOPSOIL AND SEEDED IN ACCORDANCE WITH
PERMANENT STABILIZATION METHODS INDICATED ON SOIL EROSION AND SEDIMENT CONTROL SHEET. /
TUTTE LE AREE DISTURBATE (E LE ALTRE AREE DEL SITO IN CUI NON È PRESENTE L'ERBA) DEVONO ESSERE TRATTATE CON 100 mm DI TERRENO VEGETALE IN SUPERFICIE E
SEMINATE SECONDO I METODI DI STABILIZZAZIONE PERMANENTE INDICATI SUL FOGLIO DI CONTROLLO DELL'EROSIONE DEL SUOLO E DEI SEDIMENTI.
D
TE
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:3 :3
B
IM
B P A M E R
V ic e n z a p h a se
III
A F H P S
IT
E S .r vt
MH OTVPP
S
TR
U C
TU
R
A L
G E
N E
R A
L N
O
TE
S N
O
TE
G E
N E
R A
LI
S
TR
U
TT
U
R E
S-001
14105950
1656273
V P P
1. INTERNATIONAL BUILDING CODE (2018 EDITION)
2. ACI 318-14 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE
3. UFC 1-200-01 GENERAL BUILDING REQUIREMENTS, ( OCTOBER 1, 2020)
4. UFC 1-300-09N DESIGN PROCEDURES, WITH CHANGE 4, 14 JUNE 2018
5. UFC 3-301-01 STRUCTURAL ENGINEERING, (OCTOBER 1, 2019)
6. UFC 4-010-01 DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 12
DECEMBER 2018
7. ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES
8. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) SPECIFICATION FOR
THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR
BUILDINGS, FIFTEENTH EDITION
9.AWS STRUCTURAL WELDING CODE (2015 EDITION)
10. ACI 350/350R-06 CODE REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING
CONCRETE STRUCTURES
11. D.M., CONSTRUCTION CODE (17 JANUARY 2018)
12. CIRCOLARE DEL 21 GENNAIO 2019 N. 7. INSTRUCTIONS FOR THE
APPLICATION OF THE UPDATE OF THE TECHNICAL STANDARDS FOR
CONSTRUCTION REFERRED TO IN THE MINISTERIAL DECREE OF 17 JANUARY
13. LAW N. 1086, NORMS RELATED TO NORMAL AND PRE-STRESSED
REINFORCED CONCRETE STRUCTURES AND STEEL STRUCTURES (5
NOVEMBER 1971)
14. LAW N. 64, PROVISIONS FOR STRUCTURES, WITH SPECIAL PRESCRIPTIONS
FOR THE SEISMIC ZONES (2 FEBRUARY 1974)
15. UNI EN 1090: EXECUTION OF STEEL AND ALUMINUM STRUCTURES
16. UNI EN 206: CONCRETE. SPECIFICATION, PERFORMANCE, PRODUCTION AND
COMPLIANCE
17. UNI 11104: CONCRETE. SPECIFICATION, PERFORMANCE, PRODUCTION AND
COMPLIANCE. COMPLEMENTARY INSTRUCTIONS FOR THE APPLICATION OF EN
206-1
18. UNI 8520: AGGREGATES FOR CONCRETE. COMPLEMENTARY INSTRUCTIONS
FOR THE APPLICATION OF EN 1262
19. UNI 7122: TEST ON FRESH CONCRETE. DETERMINATION OF THE AMOUNT OF
EXUDED MIXING WATER
20. EN 10080: STEEL FOR THE REINFORCEMENT OF CONCRETE
21. UNI EN 13670: EXECUTION OF CONCRETE STRUCTURES – GENERAL
REQUIREMENTS
22. CNR-DT 207/2008: INSTRUCTIONS FOR EVALUATING WIND ACTIONS AND
EFFECTS ON BUILDINGS
1. CODICE INTERNAZIONALE DELL'EDILIZIA (EDIZIONE 2018)
2. ACI 318-14 REQUISITI DEL CODICE EDILIZIO PER IL CALCESTRUZZO ARMATO
3. UFC 1-200-01 REQUISITI GENERALI PER GLI EDIFICI, (1 OTTOBRE 2020)
4. UFC 1-300-09N PROCEDURE DI PROGETTAZIONE, CON MODIFICA 4, 14
GIUGNO 2018
5. UFC 3-301-01 INGEGNERIA STRUTTURALE, (1 OTTOBRE 2019)
6. UFC 4-010-01 DOD STANDARD MINIMI ANTITERRORISMO PER GLI EDIFICI, 12
DICEMBRE 2018
7. ASCE 7-16 CARICHI MINIMI DI PROGETTO PER EDIFICI E ALTRE STRUTTURE
8. ISTITUTO AMERICANO PER LE COSTRUZIONI IN ACCIAIO (AISC) SPECIFICA
PER LA PROGETTAZIONE, LA FABBRICAZIONE E L'EREZIONE DELL'ACCIAIO
STRUTTURALE PER LE COSTRUZIONI, QUINDICESIMA EDIZIONE
9.AWS CODICE DI SALDATURA STRUTTURALE (EDIZIONE 2015)
10. ACI 350/350R-06 REQUISITI DEL CODICE PER STRUTTURE IN CALCESTRUZZO
DI INGEGNERIA AMBIENTALE
11. D.M., CODICE DI COSTRUZIONE (17 GENNAIO 2018)
12. CIRCOLARE DEL 21 GENNAIO 2019 N. 7. ISTRUZIONI PER L'APPLICAZIONE
DELL'AGGIORNAMENTO DELLE NORME TECNICHE PER LE COSTRUZIONI DI CUI
AL DECRETO MINISTERIALE 17 GENNAIO 2018
13. LEGGE N. 1086, NORME RELATIVE ALLE STRUTTURE IN CALCESTRUZZO
ARMATO NORMALE E PRECOMPRESSO E ALLE STRUTTURE IN ACCIAIO (5
NOVEMBRE 1971)
14. LEGGE N. 64, DISPOSIZIONI PER LE STRUTTURE, CON PRESCRIZIONI
SPECIALI PER LE ZONE SISMICHE (2 FEBBRAIO 1974)
15. UNI EN 1090: ESECUZIONE DI STRUTTURE IN ACCIAIO E ALLUMINIO
16. UNI EN 206: CALCESTRUZZO. SPECIFICHE, PRESTAZIONI, PRODUZIONE E
CONFORMITÀ
17. UNI 11104: CALCESTRUZZO. SPECIFICHE, PRESTAZIONI, PRODUZIONE E
CONFORMITÀ. ISTRUZIONI COMPLEMENTARI PER L'APPLICAZIONE DELLA EN
206-1
18. UNI 8520: AGGREGATI PER CALCESTRUZZO. ISTRUZIONI COMPLEMENTARI
PER L'APPLICAZIONE DELLA EN 1262
19. UNI 7122: TEST SUL CALCESTRUZZO FRESCO. DETERMINAZIONE DELLA
QUANTITÀ DI ACQUA D'IMPASTO TRASUDATA
20. EN 10080: ACCIAIO PER L'ARMATURA DEL CALCESTRUZZO
21. UNI EN 13670: ESECUZIONE DI STRUTTURE DI CALCESTRUZZO - REQUISITI
GENERALI
22. CNR-DT 207/2008: ISTRUZIONI PER LA VALUTAZIONE DELLE AZIONI DEL
VENTO E DEGLI EFFETTI SUGLI EDIFICI
CODES NORMATIVE DESING LOADS CARICHI DI PROGETTAZIONE
DESIGN LOADS ARE IN ACCORDANCE WITH UFC 3-310-01, UFC 3-310-04, ASCE7,
IBC 2018, ITALIAN LAW 1086(5/11/71), LAW 64(2/02/74), DM (17/01/18)
1. LIVE LOADS:
ROOF . . . . . . . . . 1 Kpa FLOOR . . . . . . . . . 2.0 Kpa BALCONY . . . . . . . 4.8 Kpa ELEVATOR LOBBY AND STAIRS. . . 4.8 Kpa
2. SUPERIMPOSED LOADS:
CEILING, MEP SYSTEMS AND PV PANELS 1 Kpa FLAT ROOF 0.4 kpa PITCH ROOF 0.8 kpa
3. WIND LOAD APARTMENTS AND TOWNHOUSES:
Vu ULTIMATE WIND SPEED (3 SECOND GUST) . . 41 m/s OR 148 km/h
STRUCTURAL CLASSIFICATION ENCLOSED
RISK CATEGORY . . . II
WIND EXPOSURE . . . B
INTERNAL PRESSURE COEFFICIENT GcPI=±0.18
4. WIND LOAD SUBSTATION:
Vu ULTIMATE WIND SPEED (3 SECOND GUST) . . 44 m/s OR 158 km/h
STRUCTURAL CLASSIFICATION ENCLOSED
RISK CATEGORY . . . IV
WIND EXPOSURE . . . B
INTERNAL PRESSURE COEFFICIENT GcPI=±0.18
5. WIND LOAD (ITALIAN CODE)
Vb,0 BASIC WIND SPEED . . .25 m/s BASIC VELOCITY PRESSURE, qb = 0.39 kPa
ROUGHNESS B
EXPOSURE CATEGORY: IV
INTERNAL PRESSURE COEFFICIENT: DEPENDES ON THE NUMBER OF
OPENINGS CPI (min 0/ max±0.40)
6. SEISMIC PARAMETERS (US CODE) APARTMENTS AND TOWNHOUSES:
SEISMIC IMPORTANCE FACTOR 1.0
MAPPED SPECTRAL RESPONSE ACCELERATIONS
Ss 0.76g S1 0.21g
SITE CLASS D
SPECTRAL RESPONSE COEFFICIENT
SDs 0.606g SD1 0.305g
SEISMIC DESIGN CATEGORY D
STRUCTURAL SYSTEM SPECIAL REINFORCED CONCRETE SHEAR WALL
RESPONSE MODIFICATION FACTOR R=5
SYSTEM OVERSTRENGTH FACTOR Ω=2.5
DEFLECTION AMPLIFICATION FACTOR Cd=5
7. SEISMIC PARAMETERS (US CODE) SUBSTATION:
SEISMIC IMPORTANCE FACTOR 1.5
MAPPED SPECTRAL RESPONSE ACCELERATIONS
Ss 0.76g S1 0.21g
SITE CLASS D
SPECTRAL RESPONSE COEFFICIENT
SDs 0.606g SD1 0.305g
SEISMIC DESIGN CATEGORY D
SUBSTATION
STRUCTURAL SYSTEM SPECIAL REINFORCED CONCRETE SHEAR WALL
RESPONSE MODIFICATION FACTOR R=5
SYSTEM OVERSTRENGTH FACTOR Ω=2.5
DEFLECTION AMPLIFICATION FACTOR Cd=5
8.SEISMIC PARAMETERS (ITALIAN CODE):
SITE CLASS C
SERVICEABILITY LIFE Vn=50 YEARS
OCCUPANCY CLASS II
OCCUPANCY FACTOR Cu=1.0
REFERENCE LIFE 50 YEARS
SOIL ACCELERATION FACTOR SLV ag/g=0.147g
RETURN PERIOD SLV 475
9. SNOW LOAD(US CODE):
GROUND SNOW LOAD 1.68 Kpa
IMPORTANCE FACTOR 1.0
10. SNOW LOAD (ITALIAN CODE):
GROUND SNOW LOAD 1.50 Kpa
EXPOSURE COEFFICIENT 1.0
I CARICHI DI PROGETTO SONO CONFORMI A UFC 3-310-01, UFC 3-310-04, ASCE7,
IBC 2018, LEGGE 1086(5/11/71), LEGGE 64(2/02/74), DM (17/01/18)
1. CARICHI VARIABILI:
TETTO. . . . . . . . . 1 Kpa PAVIMENTO . . . . . . . . 2.0 Kpa BALCONE . . . . . . 4.8 Kpa ATRIO DELL'ASCENSORE E SCALE ......4.8 Kpa
2. CARICHI PERMANENTI:
SOFFITTO, SISTEMI MEP E PANNELLI FV 1 Kpa TETTO PIANO 0,4 kpa TETTO A FALDE 0,8 kpa.
3. CARICO DA VENTO APPARTAMENTI E TOWNHOUSES:
VELOCITÀ MASSIMA DEL VENTO (RAFFICA DI 3 SECONDI) . 41 m/s O 148 km/h
CLASSIFICAZIONE STRUTTURALE: CHIUSO
CATEGORIA DI RISCHIO . . II
ESPOSIZIONE AL VENTO . . . B
COEFFICIENTE DI PRESSIONE INTERNA GcPI=±0,18
4. CARICO DA VENTO SOTTOSTAZIONE:
VELOCITÀ MASSIMA DEL VENTO (RAFFICA DI 3 SECONDI) . 44 m/s O 158 km/h
CLASSIFICAZIONE STRUTTURALE: CHIUSO
CATEGORIA DI RISCHIO . . IV
ESPOSIZIONE AL VENTO . . . B
COEFFICIENTE DI PRESSIONE INTERNA GcPI=±0,18
5. CARICO DA VENTO (CODICE ITALIANO)
Vb,0 VELOCITÀ DI RIFERIMENTO DEL VENTO . .25 m/s PRESSIONE DI VELOCITÀ DI BASE, qb = 0,39 kPa
RUGOSITA' B
CATEGORIA DI ESPOSIZIONE: IV
COEFFICIENTE DI PRESSIONE INTERNA: DIPENDE DAL NUMERO DI APERTURE
CPI (min 0/ max±0,40)
6. PARAMETRI SISMICI (CODICE US) APPARTAMENTI E TOWNHOUSES:
FATTORE DI IMPORTANZA SISMICA 1.0
PARAMETRI ACCELERAZIONI SPETTRALI
Ss 0.76g S1 0.21g
CATEGORIA DI SOTTOSUOLO D
COEFFICIENTI SPETTRO DI RISPOSTA ELASTICO
SDs 0.606g SD1 0.305g
CATEGORIA DI PROGETTAZIONE SISMICA D
SISTEMA STRUTTURALE: PARETI SPECIALI A TAGLIO IN CALCESTRUZZO
ARMATO
FATTORE DI COMPORTAMENTO R=5
FATTORE DI SOVRARESISTENZA Ω=2,5
FATTORE DI AMPLIFICAZIONE DELLA DEFLESSIONE Cd=5
7. PARAMETRI SISMICI (CODICE US) SOTTOSTAZIONE:
FATTORE DI IMPORTANZA SISMICA 1,5
PARAMETRI ACCELERAZIONI SPETTRALI
Ss 0.76g S1 0.21g
CATEGORIA DI SOTTOSUOLO D
COEFFICIENTI SPETTRO DI RISPOSTA ELASTICO
SDs 0.606g SD1 0.305g
CATEGORIA DI PROGETTAZIONE SISMICA D
SOTTOSTAZIONE
SISTEMA STRUTTURALE PARETI SPECIALI A TAGLIO IN CALCESTRUZZO ARMATO
FATTORE DI COMPORTAMENTO R=5
FATTORE DI SOVRARESISTENZA Ω=2,5
FATTORE DI AMPLIFICAZIONE DELLA DEFLESSIONE Cd=5
8.PARAMETRI SISMICI (CODICE ITALIANO):
CATEGORIA DI SOTTOSUOLO C
VITA NOMINALE Vn=50 ANNI
CLASSE D'USO II
COEFFICIENTE D'USO Cu=1,0
VITA DI RIFERIMENTO 50 ANNI
ACCELERAZIONE AL SUOLO SLV ag/g=0,147g
PERIODO DI RITORNO SLV 475
9. CARICO DA NEVE (CODICE US):
CARICO DA NEVE AL SUOLO 1.68 Kpa
FATTORE DI IMPORTANZA 1.0
10. CARICO DA NEVE (CODICE ITALIANO):
CARICO DA NEVE AL SUOLO 1,50 Kpa
COEFFICIENTE DI ESPOSIZIONE 1.0
D
TE
A
B
C
D
A/E INFO
SEAL
DES DRW CHK
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
PM/DM
BRANCH MANAGER
DESIGN DIRECTOR
FIRE PROTECTION
D E P A R
TM
E N T O F
TH
E
N A V Y
N A V A L F A C
IL
IT
IE
S
E N G
IN
E E R
IN
G
C O M M A N D
N O
RF
O
LK
VA
VI
LL
AG
GI
O
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
A
TL
A N
TI
C
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DRAWFORM REVISION: 25 AUGUST 2020
OF
EPROJECT NO.:
1 2 3 4 5
A
B
C
D
1 2 3 4 5
A P P R
D E S C R
IP
TI
O N
S Y M
H
AM
P
TO
N B
LV
D
VI
C
EN
ZA
IT
AL
Y
AECOM
10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011
540.857.3100 tel
540.857.3180 fax
P-
1 A
RM
Y
FA
MI
LY
H
OU
SI
NG
P
RO
JE
CT
AS NOTED
CCA/MPO
DER
R. STEPHENS, PE
DPS
P L O
TT
E D
F
IL
E
P A
TH
A U
TH
O R
Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email
6 OCT 2021
:3 :3
B
IM
B P A M E R
V ic e n z a p h a se
III
A F H P S
IT
E S .r vt
MH OTVPP
S
TR
U C
TU
R
A L
G E
N E
R A
L N
O
TE
S N
O
TE
G E
N E
R A
LI
S
TR
U
TT
U
R E
S-002
14105951
1656273
V P P
1. GENERAL NOTES AND TYPICAL DETAILS APPLY TO ALL STRUCTURAL
FEATURES UNLESS OTHERWISE SHOWN OR NOTED. IF CERTAIN FEATURES
ARE NOT FULLY SHOWN OR CALLED FOR ON THE DRAWINGS OR
SPECIFICATIONS, THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER
AS FOR SIMILAR CONDITIONS
2. ANCHORS ARE TO BE INSTALLED WITHIN A TOLERANCE OF 6mm OF
SPECIFIED LOCATION
3. A SOIL OR WASTE PIPE OR A BUILDING DRAIN, ETC PASSING UNDER A
FOOTING OR THROUGH A FOUNDATION WALL SHALL BE PROVIDED WITH A
RELIEVING ARCH, OR THERE SHALL BE BUILT INTO THE WALL OR FOUNDATION
AN IRON PIPE SLEEVE TWO PIPE SIZES GREATER THAN THE PIPE PASSING
THROUGH FOR PIPES 150mmø AND LESS AND ONE PIPE SIZE GREATER THAN THE PIPE PASSING THROUGH FOR PIPES GREATER THAN 150mmø.
4. THE STRUCTURES ARE DESIGNED TO BE SELF-SUPPORTING AND STABLE
AFTER THE BUILDING IS FULLY COMPLETED. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND
TO ENSURE THE SAFETY OF WORKERS, THE BUILDING AND ITS COMPONENT
PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER
SHORING,TEMPORARY BRACING, ETC. THAT MAY BE NECESSARY AS WELL AS
FULL COMPLIANCE WITH ALL APPLICABLE OSHA REGULATIONS. OBSERVATION
VISITS TO THE SITE BY AECOM PERSONAL SHALL NOT INCLUDE INSPECTION
FOR THESE ITEM.
5. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO ENSURE ALL WORK IS
PERFORMED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
6. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF OPENING AND
HEIGHTS OF ALL WALLS NOT SHOWN OR OTHERWISE NOTED ON THE
STRUCTURAL DRAWINGS.
7. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SIZE AND
LOCATION OF ALL FLOOR AND ROOF OPENINGS NOT SHOWN OR OTHERWISE
NOTED ON THE STRUCTURAL DRAWINGS.
8. DIMENSIONS SHALL NOT BE SCALED
9. CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND DIMENSIONS
RELATIVE TO SAME. WHERE THERE ARE CONFLICTS BETWEEN ACTUAL FIELD
CONDITIONS AND/OR DATA PRESENTED ON THESE DRAWINGS, SUCH INFORM
THE GEOTECHNICAL & ENGINEER IMMEDIATELY, AND DEVELOPE NECESSARY
ADJUSTMENTS MADE PER THEIR INSTRUCTIONS.
10. COORDINATE BONDING OF FOUNDATION REBAR TO ELECTRICAL GROUND
WITH ELECTRICAL CONTRACTOR.
11. SPECIALTY ENGINEER REQUIREMENTS: A LICENSED PROFESSIONAL
ENGINEER, WHO IS NOT THE STRUCTURAL ENGINEER OF RECORD, WHO
PROVIDES ENGINEERING CRITERIA OR DESIGNS NECESSARY FOR THE
STRUCTURE TO BE COMPLETED. THE SPECIALTY ENGINEER MAY BE A
DELEGATED ENGINEER.
12. SPECIFICATIONS, CODES, AND STANDARDS NOTED IN THESE CONTRACT
DOCUMENTS SHALL BE OF THE LATEST EDITION APPROVED BY THE
APPROPRIATE REGULATORY AGENCIES.
13. SHOP DRAWINGS AND CALCULATIONS FOR ALL STOREFRONT SYSTEMS,
CANOPIES, AND SPECIALTY ENGINEERED BUILDING ELEMENTS MUST BE
SIGNED AND SEALED BY THE CURRENTLY LICENSED ENGINEER RESPONSIBLE
FOR THE DESIGN AT TIME OF SUBMISSION
14. THE CONTRACTOR SHALL PROVIDE AND INSTALL THE FOLLOWING
PREFABRICATED ITEMS AS INDICATED IN THE DRAWINGS AND SPECIFICATIONS:
• PRESTRESSED "PREDALLE" TYPE CONCRETE PLANKS WITH CAST-IN-PLACE
TOPPING SLAB.
• IGLOO SLABS WITH POLYPROPYLENE FORMS AND CAST-IN-PLACE CONCRETE
SLAB
THEIR INSTALLATION SHALL BE COORDINATED WITH CAST-IN-PLACE PORTIONS
OF THE STRUCTURE PRIOR TO CONCRETE POURING OPERATIONS.
1. THE EXCAVATION OF ALL DEBRIS-LADEN MATERIALS AND SUBSEQUENT
REPLACEMENT WITH COMPACTED FILL LOCATED BENEATH THE ENTIRE
STRUCTURE FOOTPRINT PLUS A 1.5M MARGIN OUTSIDE THE PERIMETER
FOUNDATION IN STRICT ACCORDANCE WITH ALL OF THE RECOMMENDATIONS
BY GEOTECHNICAL ENGINEER FOR THIS PROJECT.
2.THE DEGREE OF COMPACTION OF ANY GRANULAR MATERIALS USED TO
REACH THE FINAL PROJECT LEVEL MUST BE VERIFIED BY TESTS ON A
CIRCULAR PLATE WITH A DIAMETER OF 30 CM THROUGH A DOUBLE LOADING
AND UNLOADING CYCLE ACCORDING TO THE RECOMMENDATIONS OF CNR
146/1992
3. FOUNDATIONS SHALL NOT BE PLACED ABOVE SLOPES EXCEEDING ONE
VERTICAL AND TWO HORIZONTAL AS MEASURED FROM THE CLOSEST EDGE OF
ANY UNDISTURBED SOIL OR OTHER FOUNDATION STRUCTURE.
4. ALL FOUNDATIONS SHALL BE CENTERED UNDER COLUMN OR WALL
CENTERLINES UNLESS SHOWN OR NOTED OTHERWISE.
5. REPORT ANY UNUSUAL BELOW GRADE CONDITIONS ENCOUNTERED TO THE
STRUCTURAL ENGINEER.
6. SLAB ON GRADE WILL BE SUPPORTED BY HIGH STRENGTH PLASTIC
MODULES TO PROVIDE CRAWL SPACE.
7. FOUNDATION DESIGN IS BASED ON SOIL REPORT "GEOTECHNICAL
INVESTIGATION REPORT - PHASE 1-4" PREPARED BY AECOM DATED 26TH
OCTOBER 2021.
8. CFA-TYPE REINFORCED LOAD-BEARING PILES SHALL BE INSTALLED IN
ACCORDANCE WITH THE CRITERIA ESTABLISHED BY THE DESIGNER. THE
TOTAL SETTLEMENT, UNDER SERVICE LOADS, MUST BE LIMITED TO 25 MM
ACCORDING TO THE INDICATIONS OF UFC 3-220-01 GEOTECHNICAL
ENGINEERING.
9. A GEOTECHNICAL ENGINEER SHALL OBSERVE THE OPEN EXCAVATION TO
DETERMINE THAT THE SOIL TYPE AND CONDITIONS ARE CONSISTENT WITH
DESIGN CRITERIA OF THE SOIL REPORT. IF THE SOIL PROPERTIES ARE FOUND
TO BE DIFFERENT FROM THIS CRITERIA THE OWNER’S REPRESENTATIVE SHALL
BE PROMPTLY NOTIFIED SO THAT THE FOUNDATION DESIGN MAY BE
REVIEWED.
10. TO MINIMIZE WEATHERING, THE LAST 150 mm OF EXCAVATION FOR ALL
SLABS SHALL BE MADE IMMEDIATELY PRIOR TO POURING OF SLAB.
11. QUALITY ASSURANCE COMPACTION DENSITY UNDER FOOTINGS AND SLABS
SHALL BE A MINIMUM OF "95%" OF THE MAXIMUM DRY DENSITY AS
DETERMINED BY ASTM D-1557 (MODIFIED PROCTOR) THROUGHOUT EACH 300
mm LIFT, TO A DEPTH AS INDICATED IN THE GEOTECHNICAL REPORT. IN
ADDITION TO THIS MINIMUM COMPACTION REQUIREMENT, THE BEARING SOILS
MUST EXHIBIT STABILITY AND BE FREE OF "PUMPING" CONDITIONS.
12. BELOW THE SLAB ON GRADE, A DEFORMATION MODULUS OF 80MPA SHALL
BE REACHED AFTER COMPACTION OF THE SOIL; PLATE LOAD TESTS CARRIED
OUT BY AN AUTHORIZED LABORATORY ARE REQUIRED
13. PILE LOAD TESTS HAVE TO BE CARRIED OUT FOLLOWING REQUIREMENTS
GIVEN BY NTC18, SECTION 6.4.3.7.2.
THE BUILDING CONTROLLER (COLLAUDATORE) DURING THE EXECUTION OF
THE WORKS AND/OR THE DIRECTOR OF WORKS WILL DECIDE NUMBER AND
LOCATION OF THE TESTS, MAINTAINING REQUIREMENTS OF NTC18 AS A
MINIMUM.
THE PROGRAM OF TESTS REQUIRED BY THE BUILDING CONTROLLER, WITH
THE INDICATION OF THE LOADING PROCEDURE AND THE EXPECTED
PERFORMANCES (DEFORMATIONS, STRESS LEVELS, REACTION OF THE
CONSTRAINTS, ETC.), MUST BE:
- SUBMITTED TO THE DIRECTOR OF WORKS FOR IMPLEMENTATION;
- MADE KNOWN TO THE DESIGNER, SO THAT HE CAN VERIFY ITS COMPATIBILITY
WITH THE STRUCTURAL DESIGN;
- MADE KNOWN TO THE CONTRACTOR FOR ACCEPTANCE AND EXECUTION
1. LE NOTE GENERALI E I DETTAGLI TIPICI SI APPLICANO A TUTTE LE
CARATTERISTICHE STRUTTURALI A MENO CHE NON SIA MOSTRATO O
ANNOTATO DIVERSAMENTE. SE ALCUNE CARATTERISTICHE NON SONO
COMPLETAMENTE MOSTRATE O RICHIESTE NEI DISEGNI O NELLE SPECIFICHE,
LA LORO COSTRUZIONE DEVE SEGUIRE LO STESSO PRINCIPIO SEGUITO IN
CONDIZIONI SIMILI
2. GLI ANCORAGGI DEVONO ESSERE INSTALLATI ENTRO UNA TOLLERANZA DI 6
mm DALLA POSIZIONE SPECIFICATA
3. UN TUBO DI TERRA O DI SCARICO O UN DRENAGGIO DELL'EDIFICIO, ECC.
CHE PASSA SOTTO UN BASAMENTO O ATTRAVERSO UN MURO DI FONDAZIONE
DEVE ESSERE DOTATO DI APPOSITA PROTEZIONE AD ARCO, OPPURE DEVE
ESSERE COSTRUITO NEL MURO O NELLA FONDAZIONE UN MANICOTTO IN
FERRO DI DUE DIMENSIONI MAGGIORI DEL TUBO CHE PASSA PER I TUBI DI
DIAMETRO INFERIORE A 150mmø E UNA DIMENSIONE MAGGIORE DEL TUBO CHE Passa PER TUBI SUPERIORI A 150mmø.
4. QUESTE STRUTTURE SONO PROGETTATE PER ESSERE AUTOPORTANTI E
STABILI DOPO CHE LA COSTRUZIONE DELL'EDIFICIO È ULTIMATA. È
RESPONSABILITÀ DELL'APPALTATORE DETERMINARE LA PROCEDURA E LA
SEQUENZA DI MONTAGGIO E GARANTIRE LA SICUREZZA DEI LAVORATORI,
DELL'EDIFICIO E DELLE SUE PARTI COMPONENTI DURANTE IL MONTAGGIO.
QUESTO INCLUDE L'AGGIUNTA DI QUALSIASI PUNTELLAMENTO, RINFORZO
TEMPORANEO, ECC. CHE POSSONO ESSERE NECESSARI, COSÌ COME IL PIENO
RISPETTO DI TUTTI I REGOLAMENTI OSHA APPLICABILI. LE VISITE DI
OSSERVAZIONE AL SITO DA PARTE DEL PERSONALE AECOM NON INCLUDONO
L'ISPEZIONE DI QUESTI ELEMENTI.
5. È ESCLUSIVA RESPONSABILITÀ DELL'APPALTATORE ASSICURARE CHE TUTTO
IL LAVORO SIA ESEGUITO IN CONFORMITÀ AI DOCUMENTI DEL CONTRATTO.
6. FARE RIFERIMENTO AI DISEGNI ARCHITETTONICI PER LE POSIZIONI DELLE
APERTURE E LE ALTEZZE DI TUTTE LE PARETI NON MOSTRATE O ALTRIMENTI
ANNOTATE SUI DISEGNI STRUTTURALI.
7. FARE RIFERIMENTO AI DISEGNI ARCHITETTONICI E MECCANICI PER LE
DIMENSIONI E LA POSIZIONE DI TUTTE LE APERTURE DEL PAVIMENTO E DEL
TETTO NON MOSTRATE O…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .