Attachment H - 1656273dwg12of29.pdf

PDF 28 MB Posted

Attached to
P-91331, Phase 3 Family Housing Villaggio at Vicenza, Italy
Solicitation number
N6247022R0002
Issued by

About this file

This solicitation is for Phase 3 Family Housing at Villaggio at Vicenza, Italy. The Naval Facilities Engineering Command is seeking offers for the construction of additional military family housing units at Villaggio. Offerors must submit proposals no later than April 15, 2022. The work includes site preparation, utilities infrastructure, and construction of 120 family housing units in 15 buildings. The contract is to be awarded by September 30, 2022 and have a period of performance ending September 29, 2023. The solicitation includes plans and specifications for the required work.

View the file

Other files

File Type Posted
Revised Attachment E - Schedule B Price Proposal Form_16JUN2022.pdf PDF
N6247022R0002 Amend 0007.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_16JUN2022.pdf PDF
N6247022R0002 Amend 0007.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_14JUN2022.pdf PDF
N6247022R0002 Amend 0006.pdf PDF
Attachment Q - Anti-Mafia Self-Certification Form for Contracts between 150000 and 5382000.pdf PDF
Attachment R - Anti-Mafia Self-Certification Form for Contracts greater than 5382000.pdf PDF
N6247022R0002 Amend 0005.pdf PDF
Attachment J - PSC Italian Revised Revised March 18 2022.pdf PDF
Attachment O - 1656273Amend0004 Revised Drawings .pdf PDF
N6247022R0002 Amend 0004.pdf PDF
Attachment P - Site Visit Attendance Log.pdf PDF
Attachment O - 1656273Amend0004 Revised Drawings.pdf PDF
Attachment J - PSC Italian Revised Revised March 24 2022.pdf PDF
Attachment N - 1656273Amend0004 Revised Specs.pdf PDF
Attachment E - Schedule B Price Proposal Form Revised March 24 2022.pdf PDF
N6247022R0002 Amend 0003.pdf PDF
ATTACHMENT M - 1656273Amend0003 Revised Drawings.pdf PDF
ATTACHMENT L - 1656273Amend0003 Revised Specs.pdf PDF
N6247022R0002 Amend 0002.pdf PDF
N6247022R0002 Amend 0001.pdf PDF
N6247022R0002.pdf PDF
Attachment H - 1656273dwg27of29.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment H - 1656273dwg14of29.pdf PDF
Attachment H - 1656273dwg19of29.pdf PDF
Attachment H - 1656273dwg25of29.pdf PDF
Attachment H - 1656273dwg08of29.pdf PDF
Attachment H - 1656273dwg04of29.pdf PDF
Attachment H - 1656273dwg16of29.pdf PDF
Attachment K - DWG Index.pdf PDF
Attachment H - 1656273dwg28of29.pdf PDF
Attachment H - 1656273dwg18of29.pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment H - 1656273dwg17of29.pdf PDF
Attachment I - UXO Report.pdf PDF
Attachment H - 1656273dwg26of29.pdf PDF
Attachment H - 1656273dwg29of29.pdf PDF
Attachment H - 1656273dwg07of29.pdf PDF
Attachment C - Construction Experience Project Data Sheet.pdf PDF
Attachment H - 1656273dwg15of29.pdf PDF
Attachment H - 1656273dwg23of29.pdf PDF
Attachment E - Schedule B Price Proposal Form.pdf PDF
Attachment H - 1656273dwg20of29.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
Attachment H - 1656273dwg13of29.pdf PDF
Attachment H - 1656273dwg11of29.pdf PDF
Attachment H - 1656273dwg06of29.pdf PDF
Attachment G - Specifications.pdf PDF
Show 40 more

Latest 50 of 61 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2

4 5A

B

C

D

E

F

G

H

76 8

J

K

L

M

N

P

Q

R

S 18

T U

V W X Y Z

AA

2630 2280

30°

8 °

30°

30°

2550 3890

3700 165 2635 2635 165 3700

3.360

3.360

3.360

3.360

3.360

3.360

3.360

3.360

3.360 3.360

2%

2%

2%

RE

FE

R

TO

A

S-

14000

2%

2%

3.50

3.50

3.50

3.50

3.50

3.08

3.08

3.08 3.08

3.08

3.50

3.50

3.50

3.50

3.50 3.50

3.50

3.50

3251 60

3.253

3.241

2%

3.08

3.08

3.08

3.083.50

3.50 3.50

1.780

1.780

1.780

3.241

3.254

3.256

3.255

3.50

3.50

3.50 3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.70

3.70

3.70

3.08 3.08

3.50

3.50

3.50

3.50

3.50

3.08

3.08

3.08

3.08

3.08

3.08

2.500

3.50

3.08

3.241

2%

B1

D1

F1

X1 Z1

3251 875

3.50

TH-94-W5

TH

-9

4- W

TH

-9

4- W

TH

-9

4- W

TH-94-W5

TH-94-W1

TH-94-W7

TH

-9

4- W

TH-94-W7

TH

-9

4- W

TH

-9

4- W

TH

-9

4- W

3.2412%

3.08

TH

-9

4- W

TH-94-W15

TH-94-W

TH-94-W12

TH

-9

4- W

TH-94-W

TH-94-W12

TH-94-W

TH-94-W17

TH-94-W19

TH

-94

-W

2.500 2.500

3.50 3.50

TH

-9

4- W

TH-94-W1

TH-94-W16

TH

-9

4- W

TH-94-W17

TH

-9

4- W

TH-94-W6

TH

-9

4- W

TH

-9

4- W

TH-94-W2

TH-94-W4TH-94-W4

TH

-9

4- W

TH

-9

4- W

TH-94-W8TH-94-W8

TH-94-W6

TH-94-W16

TH-94-W

TH-94-W11

TH

-9

4- W

2.500

2.500

TH-94-W7

3.70

TH

-9

4- W

TH-94-W3

TH-94-W3

TH-94-W3

3.70

3.70

TH

-9

4- W

TH

-9 4-

W

TH-94-W3 TH-94-W3

3.503.50

TH

-94

-W

8.04

8.04

8.04

8.05

8.06

8.06

8.06

8.05

3.70 3.70

TH

-94

-W

3.50 3.50

LEGEND: /

LEGENDA

INDICATES HOOKED ⌀20 BAR AT 300 O.C. INTO LOAD

BEARING CONCRETE WALL /

INDICA BARRE SAGOMATE ø20 OGNI 300 O.C. NEL MURO DI

CEMENTO ARMATO PORTANTE.

INDICATES ADDITIONAL ⌀20 AT 300 O.C. SLAB TOP BAR

REINFORCING OVER LOAD BEARING CONCRETE WALL /

INDICA BARRE AGGIUNTIVE ø20 OGNI 300 O.C. NELLA PARTE

SUPERIORE DELLA SOLETTA SOPRA LA PARETE PORTANTE DI

CEMENTO ARMATO

TH-94-Wxx = INDICATES CONCRETE WALL.

INDICA PARETE IN CLS.

= DENOTES x% SLOPE / INDICA PENDENZA DEL x%

= DENOTES SLAB-STEP /

INDICA SCALINO SULLA SOLETTA

x%

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

PLAN

NORTH

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:1 :2

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

S e n ve lo p e .r vt

MH OTVPP

TH

B

LD

G

A

R E

A A

F

IR

S T

FL

O

O R

F R

A M

IN

G

P

LA

N P

IA

N

TA

S

TR

U

TT

U

R E

T H

E D

. 2

A

R E

A B

P

IA

N O

P R

IM

O

S-148

14106000

1632846

V P P

SHEET KEYNOTES/ NOTE CHIAVE

DELLA TAVOLA:

3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER

PROSPETTO

3.50 REINFORCED CONCRETE WALL 200mm / MURO IN CALCESTRUZZO ARMATO 200mm

3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-535 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA, VEDI DETTAGLIO COSTRUTTIVO A2

DELL'ELABORATO S-535

8.04 VOID IN SLAB 1400x380mm / FORO NELLA SOLETTA 1400x380

8.05 VOID IN SLAB 560x95mm / FORO NELLA SOLETTA 560x95mm

8.06 TRIANGULAR VOID IN SLAB 400x700mm / FORO TRIANGOLARE NELLA

SOLETTA 400x700mm

SCALE 1 : 100

A1

TH BLDG 29400 AREA A FIRST FLOOR FRAMING PLAN /

PIANTA STRUTTURE TH ED. 29400 AREA A PIANO PRIMO

1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

3. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

4. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

5. BALCONY SLOPES ARE INDICATIVE AND MAY VARY. FOLLOW THE ELEVATION

LEVELS AT THE CANTILEVER END OF EACH BALCONY.

LE PENDENZE DEI BALCONI SONO INDICATIVE E POTREBBERO VARIARE.

VEDERE LE QUOTE DELLO SBALZO SUI PROSPETTI DI OGNI BALCONE

SLAB AND FRAMING NOTES /

NOTE SULLA SOLETTA E

SULL'INTELAIATURA

4 5 A

B

C

D

E

F

G

H

76 8

J

K

L

M

N

P

Q

R

S

T U

V W X Y Z

AA

2630 2280

30°

8 °

30°

30°

2550 3890 280 3700 165 2635 2635 165 3700

6.780

6.780

6.780

6.780

6.780

6.780

6.780

6.780

6.780

6.780 6.780

3.50

3.50

3.50

3.50

RE

FE

R

TO

A

S-

1400 14000

3.50

3.50

3.50

3.50 3.50

5.560

5.560

3.50

3151 60

3.50

3.50

3.50

3.50

3.08

3.08

3.08

3.503.08

3.50

5.200

5.200

5.200

3.50

3.50

3.50 3.50

3.50

3.50

3.50

3.503.50

3.50

3.503.50

3.503.50

3.08 3.08

3.08

3.08

3.08

3.08

3.50

3.70

3.70

3.70

3.70

3.70

3.50

3.50

3.50

3.50

3.50

3.50

3251 875

3.503.50 3.50

3.50

3.50

B1

D1

F1

X1 Z1

TH-94-W5

TH

-9

4- W

TH

-9 4-

W

TH-94-W1

TH-94-W7

TH-94-W7

TH

-9

4- W

TH

-9 4-

W

TH

-9

4- W

TH

-9

4- W

TH

-9 4-

W

3.50

3.50

TH

-9

4- W

TH

-94

-W

TH

-9

4- W

TH-94-W12

TH-94-W

TH-94-W12

TH-94-W11

TH-94-W

TH-94-W

TH-94-W17

TH-94-W19

TH

-94

-W

TH-94-W

TH

-94

-W

TH-94-W16

TH-94-W18

TH

-9

4- W

TH-94-W16

TH

-9 4-

W

TH-94-W17

3.08

TH-94-W6 TH-94-W6

TH

-9

4- W

TH

-9 4-

W

TH-94-W8 TH-94-W8

TH

-9

4- W

TH

-9

4- W

TH

-9

4- W

TH-94-W4

TH-94-W2

TH-94-W4

TH

-9

4- W

TH-94-W4

5.560 5.560

3.703.70

3.70 5.560

8.07

8.08

TH

-9

4- W

TH

-9

4- W

TH-94-W7

TH

-9 4-

W

LEGEND: /

LEGENDA

INDICATES HOOKED ⌀20 BAR AT 300 O.C. INTO LOAD

BEARING CONCRETE WALL /

INDICA BARRE SAGOMATE ø20 OGNI 300 O.C. NEL MURO DI

CEMENTO ARMATO PORTANTE.

INDICATES ADDITIONAL ⌀20 AT 300 O.C. SLAB TOP BAR

REINFORCING OVER LOAD BEARING CONCRETE WALL /

INDICA BARRE AGGIUNTIVE ø20 OGNI 300 O.C. NELLA

PARTE SUPERIORE DELLA SOLETTA SOPRA LA PARETE

PORTANTE DI CEMENTO ARMATO

INDICATES CONCRETE WALL/

INDICA PARETE IN CLS.

TH-94-Wxx =

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

PLAN

NORTH

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:1 :2

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

S e n ve lo p e .r vt

MH OTVPP

TH

B

LD

G

A

R E

A A

S E

C O

N D

F

LO

O R

F R

A M

IN

G

P

LA

N P

IA

N

TA

S

TR

U

TT

U

R E

T H

E D

. 2

A

R E

A A

P

IA

N O

S E

C O

N D

O

S-149

14106001

1632846

V P P

SHEET KEYNOTES/ NOTE CHIAVE

DELLA TAVOLA:

3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER

PROSPETTO

3.50 REINFORCED CONCRETE WALL 200mm / MURO IN CALCESTRUZZO ARMATO 200mm

3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-535 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA, VEDI DETTAGLIO COSTRUTTIVO A2

DELL'ELABORATO S-535

8.07 VOID IN SLAB 1100x380mm / FORO NELLA SOLETTA 1100x380mm

8.08 VOID IN SLAB 820x185mm / FORO NELLA SOLETTA 820x185mm

SCALE 1 : 100

A1

PIANTA STRUTTURE TH ED. 29400 AREA A PIANO SECONDO /

TH BLDG 29400 AREA A SECOND FLOOR FRAMING PLAN

1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

3. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

4. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

5. BALCONY SLOPES ARE INDICATIVE AND MAY VARY. FOLLOW THE ELEVATION

LEVELS AT THE CANTILEVER END OF EACH BALCONY.

LE PENDENZE DEI BALCONI SONO INDICATIVE E POTREBBERO VARIARE.

VEDERE LE QUOTE DELLO SBALZO SUI PROSPETTI DI OGNI BALCONE

SLAB AND FRAMING NOTES /

4 5 A

B

C

D

E

F

G

H

76 8

J

K

L

M

N

P

Q

R

S

T U

V W X Y Z

AA

2630 2280

30°

8 °

30°

30°

2550 3890

3865 2635 2635 3865

RI

DG

E

RIDGE

H

+5

(T

YP

H= 20+5 (TYP)

H= 20+5 (TYP)

3.61

3.61

30%

RE

FE

R

TO

A

S-

T.O.W 10.510

T.O.W 10.510

11.457

T.O.W 10.510

30%

T.O.W 11.457

12.699

T.O.W 10.799

T.

O

.W

.7

12.604

B1

D1

F1

X1 Z1

30%

30%

30%

30%

H= 20+5 (TYP)

H

+5

(T

YP

H

+5 (T

YP

30% 30% 3.66

3.66

3.66

3.66

3.66

3.66

10.491

10.491 10.469

3.66

3.61

11.824 RIDGE

10.426

RI

DG

E

30%

H= 20+5 (TYP)

11.824

RIDGE

30%

3.61

10.484 T.O.W

10.694

RIDGE10.484

T.O.W 10.510

10.688

3.66

3.66

T.

O

.W

.7

.4

12.699

H= 20+5 (TYP)

H= 20+5 (TYP)

RIDGE

3.61

T.O.W 10.455 RIDGE

11.460

T.O.W

10.492 T.O.W 10.294

T.O.W 10.492

10.688 3.66

3.61

3.61T.O.W 10.510

3.66

3.66

3.61

H= 20+5 (TYP)30

10.491

T.O.W 10.294

T.O.W 10.294

10.491

T.O.W 10.679

10.469 10.469

H= 20+5 (TYP)

3.61

3.61

3.66

3.66

T.O.W 10.272

3.61 3.61

3.66

3.66

T.

O

.W

.5

T.

O

.W

.8

T.

O

.W

.9

10.491

10.491

3.37

3.37

3.37

11.824

10.491

.4

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

PLAN

NORTH

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:1 :2

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

S e n ve lo p e .r vt

MH OTVPP

TH

B

LD

G

A

R E

A A

R O

O F

FR

A

M

IN

G P

LA

N

P

IA

N

TA

S

TR

U

TT

U R

E T

H E

D

IF

IC

IO

A

R E

A A

C O

P E

R

TU

R A

S-150

14106002

1632846

V P P

SHEET KEYNOTES/ NOTE CHIAVE

DELLA TAVOLA:

3.37 REINFORCED CONCRETE BEAM 300x400mm / TRAVE IN CALCESTRUZZO ARMATO 300x400mm

3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRAVETTI TRALICCIATI SOLAIO IN PREDALLES 250mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm

SCALE 1 : 100

A1

TH BLDG 29400 AREA A ROOF FRAMING PLAN /

PIANTA STRUTTURE TH EDIFICIO 29400 AREA A COPERTURA

1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

3. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

4. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR

PENETRATIONS NOT SHOWN /

FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E IDRAULICI PER LE

PENETRAZIONI NON MOSTRATE

5. ROOF SYSTEM IS PREDALLE SLAB SYSTEM SUPPORTED BY CAST IN PLACE

CONCRETE LOAD BEARING WALL. SEE S-531 FOR REINFORCING

IL SISTEMA DEL TETTO È UN SISTEMA DI LASTRE PREDALLE SOSTENUTO DA UN

MURO PORTANTE IN CALCESTRUZZO GETTATO IN OPERA. VEDERE S-531 PER

L'ARMATURA

6. H = HEIGHT OF ROOF STRUCTURAL SECTION (20cm PREDALLE SYSTEM + 5cm

SACRIFICIAL SLAB) /

H = ALTEZZA DELLA SEZIONE STRUTTURALE DEL TETTO (20cm SISTEMA PREDALLE + 5cm FONDELLO A PEREDE)

7. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

ROOF PLAN NOTES /

NOTE SUL PIANO DEL TETTO

AA BB CC DD EE FF GG HH

JJ

KK

LL

MM

NN

PP

QQ

RR

SS

TT

UU

VV

WW

3700 165 2635 2635 165 3700 3700 165 2635

30°

30°

8°

RE

FE

R

TO

A

S-

3.12

3.12

19500

-1.200

BB1 DD1 FF1

TT1

VV1

140 140

900 2065 1800 835 1800 835 1800 2065 1800 2065 1800 835 1040

-1.200 -1.200

-1.200

3.1013.11

3.10

3.50

3.50

54 55

66 67 68

214 215 216

218219

13.11 13.11

13.11

13.11

13.11

13.11

15200

120°

120°

7400 5600 3740

2945 3709

19640 82°

900 900 900 900 900 900

92 3400 3400

LEGEND: /

LEGENDA

= INDICATES 600mm DIAMETER AUGER CAST PILE. / INDICA IL DIAMETRO DEL PALO TRIVELLATO 600 mm

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

PLAN

NORTH

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:1 :2

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

S e n ve lo p e .r vt

MH OTVPP

TH

B

LD

G

A

R E

A B

F O

U N

D A

TI

O

N P

LA

N

P

IA

N

TA

F O

N D

A

ZI

O N

I T H

E D

IF

IC

IO

A R

E A

B

S-151

14106003

1632846

V P P

SHEET KEYNOTES/ NOTE CHIAVE

DELLA TAVOLA:

3.10 PILE CAP 600mm / PIASTRA SU PALI 600 mm

3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm

3.50 REINFORCED CONCRETE WALL 200mm / MURO IN CALCESTRUZZO ARMATO

200mm

13.11 200mm HEEL WALL BEYOND / 200mm MURO SPERONE

SCALE 1 : 100

A1

TH BLDG 29400 AREA B FOUNDATION PLAN /

PIANTA FONDAZIONI TH EDIFICIO 29400 AREA B

1. REFER TO DETAIL A2 ON SHEET S-530 FOR "CONTINUITY OF FOUNDATION

REINFORCEMENT AT CORNERS & INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A2 DELLA TAVOLA S-530 PER LA

"CONTINUITÀ DELL'ARMATURA DI FONDAZIONE AGLI ANGOLI E ALLE

INTERSEZIONI"

2. TOP OF FOUNDATION ELEVATION IS -1200 mm / LA QUOTA SUPERIORE DELLA FONDAZIONE È -1200 mm

3. REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS ADJACENT TO

BUILDING /

FARE RIFERIMENTO AI DISEGNI CIVILI PER LE QUOTE SUPERIORI DEL TERRENO

ADIACENTI ALL'EDIFICIO

4. ALL WALL FOUNDATIONS ARE WF-1800 (UNO)/

TUTTE LE FONDAZIONI DEI MURI SONO LARGHE 1800mm (SE NON ALTRIMENTI

SPECIFICATO)

5. REFER TO SHEET S-537 FOR TYPICAL PILE AND PILE CAP DETAILS /

FARE RIFERIMENTO ALLA TAVOLA S-537 PER I DETTAGLI TIPICI DEI PALI E DEI

PLINTI

6. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

7. REFER TO DETAILS B1 AND A3 OF S-531 FOR DETAIL OF FOUNDATION

EXTERIOR WALL CHANGE IN THICKNESS/

VEDI DETTAGLI B1 E A3 DELL’ELABORATO S-531 PER IL DETTAGLIO DELLA

VARIAZIONE DI SPESSORE DEL SETTO ESTERNO SULLA FONDAZIONE

FOUNDATION NOTES /

NOTE DI FONDAZIONE

AA BB CC DD EE FF GG HH

JJ

KK

LL

MM

NN

PP

QQ

RR

SS

TT

UU

VV

WW

3700 165 2635 2635 165 3700 3700 165 2635

30°

30°

8°

600 5950

-0.170

-0.170

2%

2%

2%

2%

2% 2%2%

-0.170 -0.170 -0.170

-0.170

-0.170

80 EJ

EJ

RE

FE

R

TO

A

S-

-0.562 -0.562 -0.562

3.50 3.50

3.50 3.50 3.50

3.50

3.50 3.50

3.50

3.50

3.50 3.50

3.50

3.50

2% 2%

3.70

3.50 3.50

3.50

3.50

2%

3.01

3.01 3.01

3.09

3.09 3.09

3.09

3.09

3.09

3.09

-0.537

-0.533

-0.562

-0.562

3.70

3.70

3.70

2%

2%

3.50

3.50

3.50

3.50

3.50

3.50

3.50 3.50

3.50

3.50

3.50

3.50 3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50 3.50

3.50

3.01

3.01

3.09

3.09

3.09

3.09

3.01

3.09

3.01

3.09

2% 2%

-0.109

2%

3.01

2%

-0.109

2%

2%

3.01

3.01

BB1 DD1 FF1

TT1

VV1

-0.304

-0.304

-0.303-0.304-0.304

-0.395 -0.395 -0.395

-0.395

-0.395

3.50

3.70

-0.237

-0.237

TH

-9

4- W

TH

-9

4- W

TH

-9

4- W

TH

-9

4- W

TH

-9

4- W

TH

-9

4- W

TH-94-W4

TH-94-W6 TH-94-W6

3.50 3.50

TH

-9

4- W

TH-94-W16

TH-94-W

TH

-9

4- W

3.50

TH-94-W19

3.50 3.70TH-94-W20

TH-94-W

TH-94-W17

TH-94-W

TH-94-W18

TH-94-W11

TH

-94

-W

17TH-94-W12

TH

-94

-W

TH-94-W13

TH-94-W20

TH-94-W

TH-94-W19

TH

-94

-W

TH

-94

-W

TH-94-W5

TH-94-W7

TH-94-W1

TH-94-W7

TH-94-W5

TH

-94

-W

TH

-94

-W

TH

-94

-W

TH-94-W9

TH

-94

-W

TH

-94

-W

TH-94-W9

-0 .0

-0 .0

TH

-94

-W

2%

-0.085 -0.085

3.01 3.01

3.01

TH

-94

-W

TH

-9

4- W

-0.237 -0.237 -0.237

3.01 -0.085

-0.260

-0.260

3.70

3.70

3.70

3.70

3.70

3.703.703.70

TH-94-W2

TH-94-W4

TH-94-W3 TH-94-W3 TH-94-W3 TH-94-W2

TH-94-W18

TH-94-W12

3.70

3.70

TH-94-W3

TH-94-W3

3.50

3.50

LEGEND: /

LEGENDA

TH-94-Wxx = INDICATES CONCRETE WALL.

INDICA PARETE IN CLS.

= DENOTES SLOPE /

INDICA PENDENZA

= DENOTES SLAB-STEP /

INDICA SCALINO SULLA SOLETTA

= DENOTES CAST-IN-PLACE SLAB OVER WELL COMPACTED

FILL PER GEOTECHNICAL REPORT /

INDICA SOLETTA GETTATA IN OPERA SU TERRENO BEN

COMPATTATO COME DA REPORT GEOTENICO

= DENOTES CAST-IN-PLACE SLAB OVER MODULAR SYSTEM /

INDICA SOLETTA GETTATA IN OPERA SU SISTEMA

MODULARE

X%

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

PLAN

NORTH

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:1 :3

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

S e n ve lo p e .r vt

MH OTVPP

TH

B

LD

G

A

R E

A B

G R

O U

N D

F

LO

O R

S

LA

B P

LA

N

P

IA

N

TA

S O

LA

IO

T H

E D

IF

IC

IO

A R

E A

B P

IA

N

O T

E R

R A

S-152

14106004

1632846

V P P

SHEET KEYNOTES/ NOTE CHIAVE

DELLA TAVOLA:

3.01 250mm (MIN) CAST-IN-PLACE CONCRETE SLAB WITH Ø12/300 CENTERED

EACH WAY, TOP & BOTTOM, OVER WELL COMPACTED FILL AND VAPOR

RETARDER / SOLETTA IN CALCESTRUZZO GETTATO IN OPERA Smin=250mm, CON BARRE Ø12/300, SUPERIORI ED INFERIORI IN ENTRAMBE LE DIREZIONI, GETTATA SU SOTTOFONDO BEN COMPATTATO E BARRIERA AL VAPORE

3.09 MODULAR IGLU FLOOR SYSTEM / SISTEMA MODULARE IGLU

3.50 REINFORCED CONCRETE WALL 200mm / MURO IN CALCESTRUZZO ARMATO

200mm

3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-535 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA, VEDI DETTAGLIO COSTRUTTIVO A2

DELL'ELABORATO S-535

SCALE 1 : 100

A1

TH BLDG 29400 AREA B GROUND FLOOR SLAB PLAN /

PIANTA SOLAIO TH EDIFICIO 29400 AREA B PIANO TERRA

1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

3. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

4. REFER TO DETAIL A2 ON SHEET S-530 FOR "CONTINUITY OF FOUNDATION

REINFORCEMENT AT CORNERS & INTERSECTIONS" /

FARE RIFERIMENTO AL DETTAGLIO A2 DELLA TAVOLA S-530 PER LA

"CONTINUITÀ DELL'ARMATURA DI FONDAZIONE AGLI ANGOLI E ALLE

INTERSEZIONI"

5. TOP OF SLAB-ON-GRADE ELEVATION IS -60 mm BELOW FINISHED FLOOR / LA QUOTA SUPERIORE DELLA PAVIMENTAZIONE E' -60 mm SOTTO IL PAVIMENTO

FINITO

6. REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS ADJACENT TO

BUILDING /

FARE RIFERIMENTO AI DISEGNI CIVILI PER LE QUOTE SUPERIORI DEL TERRENO

ADIACENTI ALL'EDIFICIO

7. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

8. REFER TO DETAILS B1 AND A3 OF S-531 FOR DETAIL OF FOUNDATION

EXTERIOR WALL CHANGE IN THICKNESS/

VEDI DETTAGLI B1 E A3 DELL’ELABORATO S-531 PER IL DETTAGLIO DELLA

VARIAZIONE DI SPESSORE DEL SETTO ESTERNO SULLA FONDAZIONE

SLAB NOTES /

NOTE SLAB

AA BB CC DD EE FF GG HH

JJ

KK

LL

MM

NN

PP

QQ

RR

SS

TT

UU

VV

WW

3700 165 2635 2635 165 3700 3700 165 2635

30°

30°

8°

600 5950

2% 2%

2%

2%

2%

3.360 3.360

3.360

3.360

3.360

3.360

3.360

3.360

3.360

EJ

RE

FE

R

TO

A

S-

2%

2.500

1.780

2.500

2.500

3.08

3.08

3.08

3.08

3.08

3.08 3.08

3.08

3.08

3.08

3.08

3.08 3.083.08

3.08

3.50 3.50 3.50

3.50

3.50

3.50 3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.262

3.255

3.241 3.241

3.241

3.241

3.08

2%

3.241

3.70

3.70

3.70

BB1 DD1 FF1

TT1

VV1

3.70 3.70

2.500 2.500

3.50

TH

-9

4- W

TH-94-W2

TH

-9

4- W

TH

-9

4- W

TH-94-W4

TH-94-W2

TH

-9

4- W

TH-94-W6 TH-94-W6

TH-94-W8TH-94-W8

TH

-9

4- W

TH

-9

4- W

3.50 3.50

TH

-9

4- W

TH-94-W8

TH-94-W18

TH-94-W19

TH-94-W17

TH-94-W16

TH-94-W

TH-94-W

TH-94-W18

TH-94-W19

TH-94-W12

TH

-94

-W

TH-94-W11

TH

-94

-W

TH-94-W5

TH

-94

-W

TH-94-W7

TH

-94

-W

TH

-94

-W

TH-94-W7

TH-94-W1TH

-94

-W

TH

-94

-W

TH

-94

-W

TH-94-W5

TH

-94

-W

1.780

8.04

8.04 8.05

8.06

3.70

3.70

8.05

TH-94-W4

LEGEND: /

LEGENDA

INDICATES HOOKED ⌀20 BAR AT 300 O.C. INTO LOAD

BEARING CONCRETE WALL /

INDICA BARRE SAGOMATE ø20 OGNI 300 O.C. NEL MURO DI

CEMENTO ARMATO PORTANTE.

INDICATES ADDITIONAL ⌀20 AT 300 O.C. SLAB TOP BAR

REINFORCING OVER LOAD BEARING CONCRETE WALL /

INDICA BARRE AGGIUNTIVE ø20 OGNI 300 O.C. NELLA PARTE

SUPERIORE DELLA SOLETTA SOPRA LA PARETE PORTANTE DI

CEMENTO ARMATO

TH-94-Wxx = INDICATES CONCRETE WALL.

INDICA PARETE IN CLS.

= DENOTES x% SLOPE / INDICA PENDENZA DEL x%

= DENOTES SLAB-STEP /

INDICA SCALINO SULLA SOLETTA

x%

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

PLAN

NORTH

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:1 :3

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

S e n ve lo p e .r vt

MH OTVPP

TH

B

LD

G

A

R E

A B

F

IR

S T

FL

O

O R

F R

A M

IN

G

P

LA

N P

IA

N

TA

S

TR

U

TT

U

R E

T H

E D

. 2

A

R E

A B

P

IA

N O

P R

IM

O

S-153

14106005

1632846

V P P

SHEET KEYNOTES/ NOTE CHIAVE

DELLA TAVOLA:

3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER

PROSPETTO

3.50 REINFORCED CONCRETE WALL 200mm / MURO IN CALCESTRUZZO ARMATO 200mm

3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-535 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA, VEDI DETTAGLIO COSTRUTTIVO A2

DELL'ELABORATO S-535

8.04 VOID IN SLAB 1400x380mm / FORO NELLA SOLETTA 1400x380

8.05 VOID IN SLAB 560x95mm / FORO NELLA SOLETTA 560x95mm

8.06 TRIANGULAR VOID IN SLAB 400x700mm / FORO TRIANGOLARE NELLA

SOLETTA 400x700mm

SCALE 1 : 100

A1

TH BLDG 29400 AREA B FIRST FLOOR FRAMING PLAN /

PIANTA STRUTTURE TH ED. 29400 AREA B PIANO PRIMO

1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

3. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

4. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

5. BALCONY SLOPES ARE INDICATIVE AND MAY VARY. FOLLOW THE ELEVATION

LEVELS AT THE CANTILEVER END OF EACH BALCONY.

LE PENDENZE DEI BALCONI SONO INDICATIVE E POTREBBERO VARIARE.

VEDERE LE QUOTE DELLO SBALZO SUI PROSPETTI DI OGNI BALCONE

SLAB AND FRAMING NOTES /

AA BB CC DD EE FF GG HH

JJ

KK

LL

MM

NN

PP

QQ

RR

SS

TT

UU

VV

WW

3700 165 2635 2635 165 3700 3700 165 2635 280 3100

30°

30°

8°

600 5950

6.780 6.780 6.780

6.780

6.780

6.780

6.780

6.780

6.780

3.50 3.50

3.50

RE

FE

R

TO

A

S-

3.50

3.50

TH-94-W2

3.50

3.50

3.08

3.08

3.08

3.08

3.08

3.083.08

3.70

3.70

3.70

3.70

3.50

8753.50

3.503.50

3.50

3.50 3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.50

3.70

3.50

3.50

3.50

3.50

3.50

3.50

3.50

5.560

3.50

3.50

3.50

3.50

3.50 3.50

3.50

3.50

3.50

3.50 3.50

3.50

6.780

6.780

3.50

5.560

5.560

BB1 DD1 FF1

TT1

VV1

325160

603 603

3.083.08

TH-94-W4

TH

-9

4- W

TH-94-W4

TH-94-W2

TH-94-W4

TH

-9

4- W

3.50

TH-94-W8 TH-94-W8

TH

-9

4- W

TH

-9

4- W

75.560

3.50 3.50

3.50

TH-94-W6

TH

-9

4- W

TH

-9

4- W

TH-94-W8

3.50

5.560

3.70

TH-94-W6

3.50

TH-94-W19

TH-94-W18

TH-94-W16

TH-94-W

TH-94-W

TH-94-W175.200

TH-94-W

TH-94-W19

TH-94-W18 TH-94-W12

TH

-94

-W

TH-94-W11

TH

-94

-W

TH-94-W5

TH

-94

-W

TH

-94

-W

TH-94-W1

TH

-94

-W

4 TH-94-W5

TH-94-W7

TH

-94

-W

TH

-94

-W

TH-94-W7

TH

-94

-W

TH

-94

-W

3.50

3.50

5.200

3.70

3.70

8.04

8.08

8.07

TH-94-W3

TH-94-W3

8.08

TH

-9

4- W

TH

-9 4-

W

TH

-9

4- W

TH

-9

4- W

LEGEND: /

LEGENDA

INDICATES HOOKED ⌀20 BAR AT 300 O.C. INTO LOAD

BEARING CONCRETE WALL /

INDICA BARRE SAGOMATE ø20 OGNI 300 O.C. NEL MURO DI

CEMENTO ARMATO PORTANTE.

INDICATES ADDITIONAL ⌀20 AT 300 O.C. SLAB TOP BAR

REINFORCING OVER LOAD BEARING CONCRETE WALL /

INDICA BARRE AGGIUNTIVE ø20 OGNI 300 O.C. NELLA

PARTE SUPERIORE DELLA SOLETTA SOPRA LA PARETE

PORTANTE DI CEMENTO ARMATO

INDICATES CONCRETE WALL/

INDICA PARETE IN CLS.

TH-94-Wxx =

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

PLAN

NORTH

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:1 :3

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

S e n ve lo p e .r vt

MH OTVPP

TH

B

LD

G

A

R E

A B

S E

C O

N D

F

LO

O R

F R

A M

IN

G

P

LA

N P

IA

N

TA

S

TR

U

TT

U

R E

T H

E D

. 2

A

R E

A B

P

IA

N O

S E

C O

N D

O

S-154

14106006

1632846

V P P

SHEET KEYNOTES/ NOTE CHIAVE

DELLA TAVOLA:

3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER

PROSPETTO

3.50 REINFORCED CONCRETE WALL 200mm / MURO IN CALCESTRUZZO ARMATO 200mm

3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-535 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA, VEDI DETTAGLIO COSTRUTTIVO A2

DELL'ELABORATO S-535

8.04 VOID IN SLAB 1400x380mm / FORO NELLA SOLETTA 1400x380

8.07 VOID IN SLAB 1100x380mm / FORO NELLA SOLETTA 1100x380mm

8.08 VOID IN SLAB 820x185mm / FORO NELLA SOLETTA 820x185mm

SCALE 1 : 100

A1

TH BLDG 29400 AREA B SECOND FLOOR FRAMING PLAN /

PIANTA STRUTTURE TH ED. 29400 AREA B PIANO SECONDO

1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

3. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

4. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

5. BALCONY SLOPES ARE INDICATIVE AND MAY VARY. FOLLOW THE ELEVATION

LEVELS AT THE CANTILEVER END OF EACH BALCONY.

LE PENDENZE DEI BALCONI SONO INDICATIVE E POTREBBERO VARIARE.

VEDERE LE QUOTE DELLO SBALZO SUI PROSPETTI DI OGNI BALCONE

SLAB AND FRAMING NOTES /

AA BB CC DD EE FF GG HH

JJ

KK

LL

MM

NN

PP

QQ

RR

SS

TT

UU

VV

WW

3865 2635 2635 3865 3865 2635 280 3100

30°

30°

8°

RI

DG

E

RIDGE

H=

0+

(T

YP

H= 20+5 (TYP)

H= 20+5 (TYP)

H= 20+5 (TYP)

30%

30%

3.61

RE

FE

R

TO

A

S-

T.O.W 10.510

T.O.W 11.040

T.O.W 10.510

11.457

11.457

BB1 DD1 FF1

TT1

VV1

12.604

T.O.W 10.272

H= 20+5 (TYP)

30%

30%

.5

T.

O

.W

.1

T.

O

.W

.3

T.

O

.W

.3

H=

0+

(T

YP

10.469 10.469

T.O.W 10.453

T.O.W 10.679

T.O.W 10.453

3.61

3.61

T.O.W 10.272

10.469 10.469

3.66

3.66

10.484

10.491

.4

RIDGE

3.66

3.66

3.61 35%

30%

10.491

T.O.W 10.294

3.61

3.61

T.O.W 10.294

RIDGE

11.824

30%

H= 20+5 (TYP)

3.66

RIDGE

3.66 3.66

3.66

H= 20+5 (TYP)

T.O.W 10.486

3.61

RI

DG

E

.8

T.

O.

W

.2

30%

30%

3.61

3.66

3.66

3.61 H=

0+

(T

YP

35%

.4

T.

O.

W

.2

H=

0+

(T

YP

11.607

30%30%

30%30%

10.493

10.493

10.493

3.66

3.61

3.66

3.61

3.66

10.493

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

PLAN

NORTH

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:1 :4

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

S e n ve lo p e .r vt

MH OTVPP

TH

B

LD

G

A

R E

A B

R O

O F

FR

A

M

IN

G P

LA

N

P

IA

N

TA

S

TR

U

TT

U R

E T

H E

D

IF

IC

IO

A

R E

A B

C O

P E

R

TU

R A

S-155

14106007

1632846

V P P

SHEET KEYNOTES/ NOTE CHIAVE

DELLA TAVOLA:

3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRAVETTI TRALICCIATI SOLAIO IN PREDALLES 250mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm

SCALE 1 : 100

A1

TH BLDG 29400 AREA B ROOF FRAMING PLAN /

PIANTA STRUTTURE TH EDIFICIO 29400 AREA B COPERTURA

1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

3. REFER TO SHEET S-005 FOR "WIND LOADS" /

FARE RIFERIMENTO ALLA TAVOLA S-005 PER I "CARICHI DI VENTO"

4. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR

PENETRATIONS NOT SHOWN /

FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E IDRAULICI PER LE

PENETRAZIONI NON MOSTRATE

5. ROOF SYSTEM IS PREDALLE SLAB SYSTEM SUPPORTED BY CAST IN PLACE

CONCRETE LOAD BEARING WALL. SEE S-531 FOR REINFORCING

IL SISTEMA DEL TETTO È UN SISTEMA DI LASTRE PREDALLE SOSTENUTO DA UN

MURO PORTANTE IN CALCESTRUZZO GETTATO IN OPERA. VEDERE S-531 PER

L'ARMATURA

6. H = HEIGHT OF ROOF STRUCTURAL SECTION (20cm PREDALLE SYSTEM + 5cm

SACRIFICIAL SLAB) /

H = ALTEZZA DELLA SEZIONE STRUTTURALE DEL TETTO (20cm SISTEMA PREDALLE + 5cm FONDELLO A PEREDE)

7. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

ROOF PLAN NOTES /

NOTE SUL PIANO DEL TETTO

A

A2 S-320

A2 S-320

A1 S-273

C1 S-273

C3 S-273

A3 S-273

B

3.07

C1 S-320

C1 S-320

805 6500

A1 S-320

A1 S-320

B1 S-320

B1 S-320

1055 6500

-0.780

A

A2 S-320

A2 S-320

A1 S-273

C1 S-273

C3 S-273

A3 S-273

B

3.50

3.503.50

3.50

3.07

C1 S-320

C1 S-320

A1 S-320

A1 S-320

B1 S-320

B1 S-320

-0.060

0 15

600 6700

A

A2 S-320

A2 S-320

A1 S-273

C1 S-273

C3 S-273

A3 S-273

B

3.68

3.68

C1 S-320

C1 S-320

T.O.W. 3.213

T.O.W. 3.213

4.119

A1 S-320

A1 S-320

B1 S-320

B1 S-320

3.66

3.66

RIDGE

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

PLAN

NORTH

0 421 3 5

SCALE: 1:50

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:3 :5

B

IM

B P

AM

E R

V ic e n z a p h a s e

III

A F H P V S S su b s ta ti o n .r vt

MH OTAGM

S U

B S

TA

TI

O N

P

LA

N S

P

IA

N

TA

S O

TT

O

S

TA

Z

IO

N E

S-156

14106008

1656273

A G M

SCALE 1 : 50

C2

SUBSTATION SLAB PLAN /

SOTTOSTAZIONE SOLAIO

SCALE 1 : 50

A1

SUBSTATION GROUND PLAN /

SOTTOSTAZIONE PIANO TERRA

SCALE 1 : 50

A3

SUBSTATION ROOF PLAN /

SOTTOSTAZIONE COPERTURA

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.07 FOUNDATION SLAB 600mm / PIASTRA DI FONDAZIONE 600mm

3.50 REINFORCED CONCRETE WALL 200mm / MURO IN CALCESTRUZZO ARMATO

200mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO

ARMATO 150mm

3.68 REINFORCED CONCRETE ROOF 250mm / COPERTURA IN CALCESTRUZZO

ARMATO 250mm

1. REFERENCE ELEVATION 0,0 = SEE CIVIL DRAWINGS /

QUOTA DI RIFERIMENTO 0,0 = VEDI DISEGNI CIVILI

2. REFER TO SHEETS S-001 TO S-004 FOR STRUCTURAL GENERAL NOTES /

FARE RIFERIMENTO ALLE TAVOLE DA S-001 A S-004 PER LE NOTE GENERALI

STRUTTURALI

3. TOP OF FOUNDATION ELEVATION IS -0 mm / LA QUOTA SUPERIORE DELLA FONDAZIONE È -0 mm

4. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR

PENETRATIONS NOT SHOWN /

FARE RIFERIMENTO AI DISEGNI MECCANICI, ELETTRICI E IDRAULICI PER LE

PENETRAZIONI NON MOSTRATE

5. REFER TO CIVIL DRAWINGS FOR TOP OF GRADE ELEVATIONS ADJACENT TO

BUILDING /

FARE RIFERIMENTO AI DISEGNI CIVILI PER LE ALTEZZE DELLA SUPERFICIE

ADIACENTE ALL'EDIFICIO

6. SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI ESEGUIRE IL

GETTO

GENERAL NOTES /

NOTE GENERALI

SE_GROUND TOC

-60

SE_FIRST TOC

SE_SECOND TOC

SE_THIRD TOC

10140

SE_PENTHOUSE TOC

13540

SE_ROOF SLAB TOC

13910

SE_FOUNDATION TOC

-1500

A B C D E F G H J K L

A3 S-303

3470 6505 3175 3800 2570 1230 2750 8390 2160 900

34950

TOW 11.280

TOW 15.570

TOW 14.810

TOW 15.457

1060 1570 1530 1570 1025 565 3070 3655 1170 4815 1815 1120

928 1200

1228 600

1970 875 810 1570 1530 1570 315 3070 565 1106 1970 974 315 1170 835 925 1970 1085 1815 1120

1000 1350 3500 500 1000 820 1080 1900 1000

00 22

580 600 900 600 1465 600 1400 600 1200 600 1200 600463

3.66

3.61

3.66 3.51

3.51

3.51

3.51

3.54

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.61

3.66

8.11

3.51

8.11

8.11

TOW 15.570

3.66

3.61 3.08

3.08

3.08

3.12

3.08

3.68 3.08

3.70

B1 S-303

3.22

3.22 3.51

3.51

3.51

13.11

10.200 10.178 10.200 10.947

10.349

14.590

1060 1600

3.533.08

3.08

17.644

18.814 3.66 3.61

3.15

3.53

3.18

TOW 10.130

3.08

TOW 3.330

A2 S-532

A3 S-532

1350 1000

SE_GROUND TOC

-60

SE_FIRST TOC

SE_SECOND TOC

SE_THIRD TOC

10140

SE_PENTHOUSE TOC

13540

SE_ROOF SLAB TOC

13910

SE_FOUNDATION TOC

-1500

ABCDEFGHJKL

A3 S-303

900 2160 8390 2750 1230 2570 3800 3175 6505 3470 34950

TOW 15.570

TOC 14.600

TOW 15.570TOW 15.457

TOW 10.800

765 1170

1570 2160 1570

600 2005 600 1600 600 1265 600 1265 600 1210

TOW 2.400

1370 980 1245 1570 1385 1570 1530 1570 810 875 1970 875

1745 1000 4656 2400 600 2400 1740 1600

965 1970 1115 565 3070

3.08

3.68

3.51

3.54

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.08

3.08

3.08

3.66

3.12

3.51

3.51

3.51

3.51

1000 590

3.51

3.51

3.51

B1 S-303

3.22 3.22

14.590

6.640

3.240

2%

2%

17.644 17.644

18.814 3.66 3.61

3.15

TOW 3.3303.53

3.08

3.18 3.53

TOW 10.130

RIDGE

3.51

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:0 :4

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

S e n ve lo p e .r vt

MH OTAGM

A P

B U

IL

D

IN

G

F

A C

A D

E E

LE

V

A

TI

O N

S A

P E

D

IF

IC

IO

P

R O

S P

E

TT

I F A

C C

IA

TA

S-201

14106009

1656273

A G M

SCALE 1 : 100 (S-102)

C1

AP BUILDING 27100 FACADE ELEVATION WEST /

APPARTAMENTO 27100 PROSPETTO OVEST

SCALE 1 : 100 (S-101)

A1

AP BUILDING 27100 FACADE ELEVATION EAST /

APPARTAMENTO 27100 PROSPETTO EST

SHEET KEYNOTES

3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER

PROSPETTO

3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.18 180mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION /

3.22 REINFORCED CONCRETE COLUMN C1 ONLY AT GROUND FLOOR. SEE

DETAIL A1 ON SHEET S-532 / PILASTRO IN CALCESTRUZZO ARMATO C1

SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-532

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm

3.53 REINFORCED CONCRETE WALL 400mm / MURO IN CALCESTRUZZO ARMATO 400mm

3.54 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO

3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRAVETTI TRALICCIATI SOLAIO IN PREDALLES 250mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm

3.68 REINFORCED CONCRETE ROOF 250mm / COPERTURA IN CALCESTRUZZO ARMATO 250mm

3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-535 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA, VEDI DETTAGLIO COSTRUTTIVO A2

DELL'ELABORATO S-535

8.11 SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI FARE LA

COLATA

13.11 200mm HEEL WALL BEYOND / 200mm MURO SPERONE

SE_FIRST TOC

SE_SECOND TOC

SE_THIRD TOC

10140

SE_PENTHOUSE TOC

13540

SE_ROOF SLAB TOC

13910

SE_FOUNDATION TOC

-1500

A B C D E F G H J K L

A3 S-303A

B1 S-303A

3470 6505 3175 3800 2570 1230 2750 8390 2160 900

34950

TOW 15.570

TOW 14.810

TOW 15.570 TOW 15.457

10.200 10.349

TOW 11.280

TOW 10.130

3.66 3.6130%

3.51

3.66

3.51

3.51

3.51

3.51

3.51

1060 1570 1530 1570 1025 565 3070 3655 1170 4815 1815 1120

3.61 3.66

3.613.66

3.66 3.61

3.51

10.20010.178 10.947

580 600 900 600 1465 600 1400 600 1200 600 1200 600

3.51

3.51

3.54

1600 4190 3500 1350 1000

500 1000 820 1080 1900

TOW 3.330

3.51

3.51

3.51

3.51

3.51

3.51

3.7013.11

8.11

3.51

3.51

3.68

3.53

3.22 3.22

3.15

3.12

SE_GROUND TOC

-60

SE_FIRST TOC

SE_SECOND TOC

SE_THIRD TOC

10140

SE_PENTHOUSE TOC

13540

SE_ROOF SLAB TOC

13910

SE_FOUNDATION TOC

-1500

ABCDEFGHJKL

A3 S-303A

B1 S-303A

900 2160 8390 2750 1230 2570 3800 3175 6505 3470 34950

TOW 15.457

18.814

17.64417.644

TOW 15.570

TOW 14.600

TOW 15.570

RIDGE

TOW 10.800

4775 1570 2160 1570 725

765 1170

1370 980 1245 1570 1385 1570 1530 1570 810 875 1970 875

1970 1115 565 3070 315

455 600 2005 600 1600 600 1265 600 1265 600

460 1000

800 650

TOW 2.4003.51

1000 4656 2400 600 2400 1740 1600 16

TOW 3.330 3.53 3.68

3.08 3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.51

TOW 10.130

3.18 3.08

3.51

3.51

3.51

6.640

3.240

3.08

3.08 3.51

3.51

3.51

3.51

3.51

3.51

3.51

3.54

3.51

3.51

3.15

3.12

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:0 :4

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

S e n ve lo p e .r vt

MH OTAGM

A P

B U

IL

D

IN

G

F

A C

A D

E E

LE

V

A

TI

O N

B

ID

O P

TI

O

N A

P E

D

IF

IC

IO

P

R O

S P

E

TT

I F A

C C

IA

TA

O P

ZI

O

N E

O

FF

E R

TA

S-201A

14106010

1656273

A G M

SCALE 1 : 100

C1

AP BUILDING 27100 FACADE ELEVATION WEST /

APPARTAMENTO 27100 PROSPETTO OVEST

SCALE 1 : 100

A1

AP BUILDING 27100 FACADE ELEVATION EAST /

APPARTAMENTO 27100 PROSPETTO EST

SHEET KEYNOTES

3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER

PROSPETTO

3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.18 180mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION /

3.22 REINFORCED CONCRETE COLUMN C1 ONLY AT GROUND FLOOR. SEE

DETAIL A1 ON SHEET S-532 / PILASTRO IN CALCESTRUZZO ARMATO C1

SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-532

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm

3.53 REINFORCED CONCRETE WALL 400mm / MURO IN CALCESTRUZZO ARMATO 400mm

3.54 REINFORCED CONCRETE WALL 460mm ONLY AT FIRST FLOOR / MURO IN CALCESTRUZZO ARMATO 460mm SOLO AL PRIMO PIANO

3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRAVETTI TRALICCIATI SOLAIO IN PREDALLES 250mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm

3.68 REINFORCED CONCRETE ROOF 250mm / COPERTURA IN CALCESTRUZZO ARMATO 250mm

3.70 CAST IN PLACE CONCRETE STAIR. SEE DETAILS ON SHEET S-535 / SCALA IN

CALCESTRUZZO GETTATO IN OPERA, VEDI DETTAGLIO COSTRUTTIVO A2

DELL'ELABORATO S-535

8.11 SEE MEP DRAWINGS FOR ALL NECESSARY HOLES BEFORE POURING /

VEDERE I DISEGNI MEP PER TUTTI I FORI NECESSARI PRIMA DI FARE LA

13.11 200mm HEEL WALL BEYOND / 200mm MURO SPERONE

SE_FIRST TOC

SE_SECOND TOC

SE_THIRD TOC

10140

SE_PENTHOUSE TOC

13540

SE_ROOF SLAB TOC

13910

SE_FOUNDATION TOC

-1500

1234567891011121314151617

1000 2410 500 2415 985 715

3450 450 925 2800

660 1500

20850

TOW 15.570

3601 2400 600 2400 3100 2400 600 2400 600 1600 1399

11151120

3.61

3.663.51

3.51

3.51

A1 S-301

A1 S-302

3.22

30%

3.51

10.200

3.15

3.12

8.10

1120 3400 1120 7729

SE_GROUND TOC

-60

SE_FIRST TOC

SE_SECOND TOC

SE_THIRD TOC

10140

SE_PENTHOUSE TOC

13540

SE_ROOF SLAB TOC

13910

SE_FOUNDATION TOC

-1500

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

100024105002415985715

34504509252800

6601500

20850

1039 1970 1041 605 1570 1340 1570 1605 2170 630 1295 1370 995

30 17

1725 600 2815 600 2310 600

TOW 15.457

3.51

3.51

3.51

3.51

620217062013921370

2000 1076 1045 1370 995

3.12

3.663.66

3.08

3.08

3.08

3.08

3.08

3.08

A1 S-301

A1 S-302

14.590 14.590

3.53

3.15

3.18

TOW 10.130

30%

600 1530

30%

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:0 :4

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

S e n ve lo p e .r vt

MH OTAGM

A P

B U

IL

D

IN

G

F

A C

A D

E E

LE

V

A

TI

O N

S A

P E

D

IF

IC

IO

P

R O

S P

E

TT

I F A

C C

IA

TA

S-202

14106011

1656273

A G M

SCALE 1 : 100 (S-102)

C1

AP BUILDING 27100 FACADE ELEVATION NORTH /

APPARTAMENTO 27100 PROSPETTO NORD

SCALE 1 : 100 (S-102)

A1

AP BUILDING 27100 FACADE ELEVATION SOUTH /

APPARTAMENTO 27100 PROSPETTO SUD

SHEET KEYNOTES

3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER

PROSPETTO

3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.18 180mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION /

3.22 REINFORCED CONCRETE COLUMN C1 ONLY AT GROUND FLOOR. SEE

DETAIL A1 ON SHEET S-532 / PILASTRO IN CALCESTRUZZO ARMATO C1

SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-532

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm

3.53 REINFORCED CONCRETE WALL 400mm / MURO IN CALCESTRUZZO ARMATO 400mm

3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRAVETTI TRALICCIATI SOLAIO IN PREDALLES 250mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm

8.10 OPENINGS SHOWN AS DASHED ARE INDICATIVE OF OPENING LOCATION

WHEN PROTOTYPE DOES NOT ADJOIN ANOTHER BUILDING / LE APERTURE

INDICATE COME TRATTEGGIATE SONO INDICATIVE DELLA POSIZIONE

DELL'APERTURA QUANDO IL PROTOTIPO NON CONFINA CON UN ALTRO

EDIFICIO

SE_FIRST TOC

SE_SECOND TOC

SE_THIRD TOC

10140

SE_PENTHOUSE TOC

13540

SE_ROOF SLAB TOC

13910

SE_FOUNDATION TOC

-1500

1234567891011121314151617

A1 S-301A

A1 S-302A

1000 2410 500 2415 985 715

3450 450 925 2800

660 1500

20850

TOW 15.570

10.200

30% 3.66 3.61

1120 1115

1120 3400 1120 7729

2400 600 2400 3100 2400 600 2400 600 1600 139916

3.51

3.51

3.51

3.51 3.22

3.15

3.12

8.10

SE_GROUND TOC

-60

SE_FIRST TOC

SE_SECOND TOC

SE_THIRD TOC

10140

SE_PENTHOUSE TOC

13540

SE_ROOF SLAB TOC

13910

SE_FOUNDATION TOC

-1500

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A1 S-301A

A1 S-302A

100024105002415985715

34504509252800

17190

TOW 15.457

14.590 14.59030% 30%

1039 1970 1646 1570 1340 1570 1605 2170 1925 1370

TOW 10.130 3.533.18

3.08

3.08

3.08

2000 1076 1045 1370

600 153024

3.15

3.12

3.51

3.51

3.51

3.51

1725 600 1725 1090 600 2310 600

3.66 3.66

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:0 :4

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

S e n ve lo p e .r vt

MH OTAGM

A P

B U

IL

D

IN

G

F

A C

A D

E E

LE

V

A

TI

O N

B

ID

O P

TI

O

N A

P E

D

IF

IC

IO

P

R O

S P

E

TT

I F A

C C

IA

TA

O P

ZI

O

N E

O

FF

E R

TA

S-202A

14106012

1656273

A G M

SCALE 1 : 100

C1

AP BUILDING 27100 FACADE ELEVATION NORTH /

APPARTAMENTO 27100 PROSPETTO NORD

SCALE 1 : 100

A1

AP BUILDING 27100 FACADE ELEVATION SOUTH /

APPARTAMENTO 27100 PROSPETTO SUD

SHEET KEYNOTES

3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER

PROSPETTO

3.12 CONCRETE PILE D=600mm / PALO IN CALCESTRUZZO D=600 mm

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.18 180mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION /

3.22 REINFORCED CONCRETE COLUMN C1 ONLY AT GROUND FLOOR. SEE

DETAIL A1 ON SHEET S-532 / PILASTRO IN CALCESTRUZZO ARMATO C1

SOLO AL PIANO TERRA. VEDI DETTAGLIO A1 SUL FOGLIO S-532

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO 250mm

3.53 REINFORCED CONCRETE WALL 400mm / MURO IN CALCESTRUZZO ARMATO 400mm

3.61 PREDALLES REINFORCED SLAB TRELLIS 250mm / TRAVETTI TRALICCIATI SOLAIO IN PREDALLES 250mm

3.66 REINFORCED CONCRETE ROOF 150mm / COPERTURA IN CALCESTRUZZO ARMATO 150mm

8.10 OPENINGS SHOWN AS DASHED ARE INDICATIVE OF OPENING LOCATION

WHEN PROTOTYPE DOES NOT ADJOIN ANOTHER BUILDING / LE APERTURE

INDICATE COME TRATTEGGIATE SONO INDICATIVE DELLA POSIZIONE

DELL'APERTURA QUANDO IL PROTOTIPO NON CONFINA CON UN ALTRO

EDIFICIO

-60.000

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

ABE

3.08

3.08

3.08

3.15

3.08

12547351901145

11778255758255758253270

3.51 3.51

3.51

3.51

19.450

18.600

-1.500

2.700

4880 2160

SE_FOUNDATION TOC

-1500.000

HIJK 380096803470

96519701115565307031615701530157016851970875

14.610

15.570

3.51

3.51 3.51

-1.500

15.570

3.54

3.08

3.08

3.08

3.15

111516451256244545524456552445166916451175

700473

H I J K3800 9680 3470

3.68

3.08

3.08

3.08

3.15

3.08

3.08

3.08

965 1970 1115 565 3070 335 1570 1510 1570 810 875 1970 750 125

3.51 3.51

14.610

15.570

14.610

15.570

3.51

-1.500

1900 1025 2568 3525 1325 737 1000 525 837 1000 1758

3.53

430793

7 59

SE_GROUND TOC

-60.000

SE_FIRST TOC

3340.000

SE_SECOND TOC

6740.000

SE_THIRD TOC

10140.000

SE_PENTHOUSE TOC

13540.000

A G10390

3.08

3.08

3.08

8.11

16.190

14.600

58066682817

3.51

3.51

3.51

3.51

3.51

16.041

3.66 30%

15.570

9663 580 450

640 1253 1000

SE_FOUNDATION TOC

-1500.000

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

1:100

0 1 32 4 5 10

SCALE:

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:5 :3

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

S e n ve lo p e .r vt

MH OTVPP

A P

B U

IL

D

IN

G

F

A C

A D

E E

LE

V

A

TI

O N

S A

P E

D

IF

IC

IO

P

R O

S P

E

TT

I F A

C C

IA

TA

S-203

14106013

1656273

V P P

SCALE 1 : 100

B1

AP BUILDING 27200 FACADE ELEVATION EAST /

APPARTAMENTO 27200 PROSPETTO EST

SCALE 1 : 100

A1

AP BUILDING 27200 FACADE ELEVATION WEST /

APPARTAMENTO 27200 PROSPETTO EST

SHEET KEYNOTES / NOTE CHIAVE

DELLA TAVOLA:

3.08 250mm CAST IN PLACE REINFORCED CONCRETE SLAB WITH Ø12/150 EACH

WAY TOP AND BOTTOM. SEE PLAN FOR ELEVATION / SOLETTA IN

CALCESTRUZZO GETTATO IN OPERA 250mm CON BARRE Ø12/150

SUPERIORE ED INFERIOREIN OGNI DIREZIONE. VEDI PIANTA PER

PROSPETTO

3.15 PILE CAP 1000mm / PIASTRA SU PALI 1000mm

3.51 REINFORCED CONCRETE WALL 250mm / MURO IN CALCESTRUZZO ARMATO

250mm

3.53 REINFORCED CONCRETE WALL 400mm / MURO IN CALCESTRUZZO…