Attachment H - 1656273dwg08of29.pdf

PDF 21 MB Posted

Attached to
P-91331, Phase 3 Family Housing Villaggio at Vicenza, Italy
Solicitation number
N6247022R0002
Issued by

About this file

This solicitation is for Phase 3 Family Housing at Villaggio at Vicenza, Italy. The Naval Facilities Engineering Command is seeking offers for the construction of additional military family housing units at Villaggio. Offerors must submit proposals no later than April 8, 2022. The work includes site preparation, utilities infrastructure, and construction of 48 two-bedroom and 12 three-bedroom townhome units. The period of performance is 730 calendar days following issuance of the notice to proceed. The anticipated award date is July 2022. This project is not set aside for small businesses.

View the file

Other files

File Type Posted
Revised Attachment E - Schedule B Price Proposal Form_16JUN2022.pdf PDF
N6247022R0002 Amend 0007.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_16JUN2022.pdf PDF
N6247022R0002 Amend 0007.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_14JUN2022.pdf PDF
N6247022R0002 Amend 0006.pdf PDF
Attachment Q - Anti-Mafia Self-Certification Form for Contracts between 150000 and 5382000.pdf PDF
Attachment R - Anti-Mafia Self-Certification Form for Contracts greater than 5382000.pdf PDF
N6247022R0002 Amend 0005.pdf PDF
Attachment J - PSC Italian Revised Revised March 18 2022.pdf PDF
Attachment O - 1656273Amend0004 Revised Drawings .pdf PDF
N6247022R0002 Amend 0004.pdf PDF
Attachment P - Site Visit Attendance Log.pdf PDF
Attachment O - 1656273Amend0004 Revised Drawings.pdf PDF
Attachment J - PSC Italian Revised Revised March 24 2022.pdf PDF
Attachment N - 1656273Amend0004 Revised Specs.pdf PDF
Attachment E - Schedule B Price Proposal Form Revised March 24 2022.pdf PDF
N6247022R0002 Amend 0003.pdf PDF
ATTACHMENT M - 1656273Amend0003 Revised Drawings.pdf PDF
ATTACHMENT L - 1656273Amend0003 Revised Specs.pdf PDF
N6247022R0002 Amend 0002.pdf PDF
N6247022R0002 Amend 0001.pdf PDF
N6247022R0002.pdf PDF
Attachment H - 1656273dwg27of29.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment H - 1656273dwg14of29.pdf PDF
Attachment H - 1656273dwg19of29.pdf PDF
Attachment H - 1656273dwg12of29.pdf PDF
Attachment H - 1656273dwg25of29.pdf PDF
Attachment H - 1656273dwg04of29.pdf PDF
Attachment H - 1656273dwg16of29.pdf PDF
Attachment K - DWG Index.pdf PDF
Attachment H - 1656273dwg28of29.pdf PDF
Attachment H - 1656273dwg18of29.pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment H - 1656273dwg17of29.pdf PDF
Attachment I - UXO Report.pdf PDF
Attachment H - 1656273dwg26of29.pdf PDF
Attachment H - 1656273dwg29of29.pdf PDF
Attachment H - 1656273dwg07of29.pdf PDF
Attachment C - Construction Experience Project Data Sheet.pdf PDF
Attachment H - 1656273dwg15of29.pdf PDF
Attachment H - 1656273dwg23of29.pdf PDF
Attachment E - Schedule B Price Proposal Form.pdf PDF
Attachment H - 1656273dwg20of29.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
Attachment H - 1656273dwg13of29.pdf PDF
Attachment H - 1656273dwg11of29.pdf PDF
Attachment H - 1656273dwg06of29.pdf PDF
Attachment G - Specifications.pdf PDF
Show 40 more

Latest 50 of 61 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B1 CONCRETE WALK/MARCIAPIEDE IN CALCESTRUZZO

NO SCALE / NON IN SCALA

C2 CONCRETE WALK - JOINT DETAIL

NON IN SCALA

NO SCALE

MARCIAPIEDE IN CLS/PARTICOLARE GIUNTO

C4

CS101

B4

AS101

WALK WIDTH / LONGITUDINAL CONTRACTION JOINT /

LARGHEZZA MARCIAPIEDE GIUNTI DI CONTRAZIONE LONGITUDINALI

<1800 NONE / NESSUNO

1800 TO <2400 ONE ALONG WALK AT CENTERLINE / UNO LUNGO IL CENTRO DEL MARCIAPIEDE

2400 TO 3600 TWO ALONG WALK AT THIRD POINTS / DUE LUNGO IL TERZO DEL MARCIAPIEDE

ISOLATION JOINT WHERE WALK ABUTS

CURB, PAVEMENT OR STEPS/

GIUNTI DI ISOLAMENTO IN PROSSIMITA' DI

CORDOLI, PAVIMENTAZIONI O GRADINI

LONGITUDINAL

CONTRACTION JOINT/

GIUNTI LONGITUDINALI DI

CONTRAZIONE

TRANSVERSE EXPANSION JOINT/

GIUNTI DI ESPANSIONE TRASVERSALI

1500 TYP

15m OR MATCH JOINTS OF CURB WHEN ADJACENT (SEE NOTE1) /

15m OPPURE INCONTRARE I GIUNTI DEL CORDOLO QUANDO SONO

ADIACENTI

(VEDI NOTA 1)

SE

E

PL

AN

S

(SEE NOTE 1)

(VEDI NOTA 1)

NOTES/NOTE:

1. REFER TO CJ100-SERIES SHEETS FOR DESIGN INTENT OF CONCRETE JOINT LAYOUT. /

FARE RIFERIMENTO ALLE FOGLI DELLA SERIE CJ100 PER LA PROGETTAZIONE DEL DISPOSIZIONE

DEL GIUNTO CONCRETO.

2. REFER TO JOINT SEALANT DETAILS. /

VEDERE PARTICOLARE SIGILLATURA GIUNTI

CONTRACTION

JOINT, 25 DEEP

(SEE NOTE 2)/GIUNTO DI

CONTRAZIONE ,

PROFONDITA' 25EXPANSION JOINT (SEE NOTE 2)/

GIUNTO DI ESPANSIONE (VEDI NOTA 2)

150x150 - MW9xMW9

WELDED WIRE FABRIC/

RETE ELETTROSALDATA

SMOOTH, COMPACTED SUBGRADE

SOTTOFONDO LISCIO COMPATTATO

100 AGGREGATE

BASE COURSE/

STRATO DI BASE

AGGREGATO

75 CLR AT

JOINTS (TYP)

GIUNTO (TIP)

NOTE/NOTA:

COMPACT SUBGRADE AND AGGREGATE BASE COURSES TO 95% ASTM D1557, UNO. /

SOTTOFONDO E STRATO DI BASE AGGREGATO COMPATTATO AL 95% ASTM D1557,UNO

LONGITUDINAL SECTION / SEZIONE LONGITUDINALE

PARTIAL PLAN / PIANTA PARZIALE

h d hd

SEE JOINT SEALANT DETAILS/

VEDERE PARTICOLARE SIGILLATURA GIUNTI

BUTT JOINT FOR LONGITUDINAL OR TRANSVERSE JOINTS/

GIUNTO DI TESTA PER GIUNTI LONGITUDINALI O TRASVERSALI

h d h d

CONCRETE SLAB/

SOLETTA IN CALCESTRUZZO

BUILDING OR STRUCTURE/

EDIFICIO O STRUTTURA

CONTRACTION JOINT / GIUNTO DI CONTRAZIONE

CONSTRUCTION JOINT / GIUNTO DI COSTRUZIONE

ISOLATION JOINT / GIUNTO DI ISOLAMENTO

SEE JOINT SEALANT DETAILS/

VEDERE PARTICOLARE SIGILLATURA GIUNTI

SEE JOINT SEALANT DETAILS/

VEDERE PARTICOLARE SIGILLATURA

GIUNTI

PREFORMED NON-EXTRUDING

JOINT FILLER MATERIAL /

MATERIALE NON ESTRUSO

PREFORMATO DI RIEMPIMENTO GIUNTO

1 800

PVMT

300 450

2 - 13 (MIN)

15038 38

A1 PRECAST WHEEL STOP/FERMARUOTE PREFABBRICATI

NO SCALE / NON IN SCALA

ELEVATION / PROSPETTO

END VIEW / VISTA LATERALE

19 DIA STL RODS 750 LONG BOTH

ENDS/ BULLONI DIAM 19 OGNI 750

LUNGO ENTRAMBI I LATI

6 0006 000

2 7

2 7

45°

300SPA

1 500 2 4002 400

5 5

5 6

(2400 MIN IF VAN

ACCESSIBLE)

A3 PARKING SPACE MARKINGS/STRISCE POSTO PARCHEGGIO

NO SCALE / NON IN SCALA

DOUBLE PARKING STALL /

DUE POSTI PARCHEGGI

PARKING STALL ABUTTING OPEN SPACE /

POSTO PARCHEGGIO IN AREA APERTA

ACCESSIBLE PARKING STALL /

POSTO PARCHEGGIO ACCESSIBILE

OPEN SPACE/

SPAZIO APERTO

FACE OF CURB/

FACCIA DEL CORDOLO

120 WIDE WHITE STRIPE/

STRISCE LARGHE 120

BIANCHE

WHEEL STOP

(TYP) /

BLOCCA

RUOTE (TIP)

120 WIDE YELLOW

STRIPE, TYP/

STRISCE LARGHE

120 GIALLA

B4

AS101

300 R

150 DIA

150 TYP

75+

C3 ACCESSIBLE SYMBOL/SIMBOLO ACCESSIBILITA'

NO SCALE / NON IN SCALA

CENTER SYMBOL BETWEEN

PARKING STRIPES/ CENTRO

DEL SIMBOLO TRA LE

STRISCE DEL PARCHEGGIO

A4 ACCESSIBLE RAMP DETAILS

NON IN SCALA

NO SCALE

PARTICOLARE RAMPA ACCESSIBILITA'

A5 SPEED TABLE DETAIL

NON IN SCALA

NO SCALE

PARTICOLARE RAMPA ACCESSIBILITA'

TOP OF FINISH GRADE /

SOMMITA' LIVELLO FINITO

TOP OF TABLE / PARTE SUPERIORE

DEL PIANO

ASPHALT BINDER COURSE INCREASED IN THICKNESS /

STRATO DI LEGANTE D'ASFALTO AUMENTATO IN SPESSORE

50 ASPHALT SURFACE COURSE /

50 STRATO SUPERFICIE ASFALTATA

ASPHALT BASE LAYER /

STRATO DI BASE IN ASFALTO

FINISH PAVEMENT/

PAVIMENTO FINITO

COMPACTED SUBGRADE/

SOTTOFONDO COMPATTATO

FACE OF CURB/

FACCIA DEL CORDOLO

1 800 1 800 RAMP FLOOR

/ 1 800 RAMPA

1 800

0 M

IN

1 800 1 200 (UNO) 1 800

RAMP - TYPE "B" / RAMPA TIPO "B"

RAMP - TYPE "A" / RAMPA TIPO "A"

PLAN

PIANTA

SECTION/

SEZIONE

PLAN

PIANTA

SECTION/

SEZIONE

FACE OF CURB/

FACCIA DEL CORDOLO

MAX SLOPE 8% /

PENDENZA MAX 8% MAX SLOPE 8% /

PENDENZA MAX. 8%

MA

X

SL

OP

E 8%

PE

ND

EN

ZA

M

AX

8%

FINISH PAVEMENT/

PAVIMENTO FINITO

COMPACTED SUBGRADE/

SOTTOFONDO COMPATTATO

RAMP FLOOR BROOM FINISH/

PAVIMENTO RAMPA CON FINITURA

SPAZZOLATA

600 X 1200 PRECAST CONCRETE

DETECTABLE WARNING PAVERS/

600 X 1200 PAVIMENTAZIONE TATTILE

CALCESTRUZZO PREFABBRICATO

MAX SLOPE 8% /

PENDENZA MAX 8% MAX SLOPE 8% /

PENDENZA MAX. 8%

MA

X

SL

OP

E 8%

PE

ND

EN

ZA

M

AX

8%

IMPERVIOUS CONCRETE PAVERS, SEE

DETAIL A2 SHEET LS501 / MASSELLI

CEMENTIZI IMPERMEABILI, VEDI

DETTAGLIO A2 SU TAVOLA LS501

IMPERVIOUS CONCRETE PAVERS, SEE

DETAIL A2 SHEET LS501 / MASSELLI

CEMENTIZI IMPERMEABILI, VEDI

DETTAGLIO A2 SU TAVOLA LS501

RAMP FLOOR BROOM FINISH/

PAVIMENTO RAMPA CON FINITURA

SPAZZOLATA

600 X 1200 PRECAST CONCRETE

DETECTABLE WARNING PAVERS/

600 X 1200 PAVIMENTAZIONE TATTILE

CALCESTRUZZO PREFABBRICATO

B1 C-502

B4

CS101

B4

CS101

B2

CS102

SEE SHEET CP701 FOR

VERTICAL SIGN /

VEDERE TAVOLA CP701 PER

IL SEGNALE VERTICALE

NOTE/NOTA:

ROAD MARKING MUST BE IN ACCORDANCE WITH NUOVO CODICE DELLA STRADA. /

MARCATURA DI PAVIMENTAZIONE DEVONO ESSERE CONFORMI AL NUOVO CODICE DELLA STRADA.

120 WIDE YELLOW

STRIPE / STRISCE

LARGHE 100

BIANCHE

150 (VARIES) SEE PLAN /

150 (VARIABILE) VEDI PIANTA

SE

E

DE

T

A1 /50

FO

R

TY

P

LA

YE

R

/ V

ED

ER

E

DE

TT

AG

LIO

A 1/5

PE

R

TI

PO

D

I

ST

RA

TI

GR

AF

IA

La st s av ed b y:

W

IS

EM

AN

M

(2

1-

-2 1)

La st P lo tte d:

1-

-2

Fi le na m e:

L :\D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\C

\1

-C -5

-1

4.

D

W G

La st s av ed b y:

W

IS

EM

AN

M

(2

1-

P lo tte d:

1-

-2

Fi le na m e:

L :\D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\C

\1

-C -5

-1

4.

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

P-

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

DRAWFORM REVISION: 20 AUGUST 2020

AS NOTED

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

C-502

CI

VI

L D

ET

AI

LS

DE

TT

AG

LI

CI

VI

LI

SECTION / SEZIONE

CORROSION RESISTANT MATERIAL

MATERIALE ANTI-CORROSIVO

#13 REINFORCING BAR /

#13 BARRA DI RINFORZO

300 MIN 400 MAX

250 MIN CLEAR STEP WIDTH /

250 MIN LARGHEZZA PASSO NETTA

230 MIN

NOTES / NOTE:

1. VERT SP - 400 C TO C. / VERT SP - 400 C A C.

2. STEPS TO PROTRUDE 125 FROM FACE OF STRUCTURE WALL. / I GRADINI DEVONO

SPORGERE DI 125 DALLA FACCIA DEL MURA DELLA STRUTTURA.

3. PORTION OF AL STEP EMBEDDED IN CONC SHALL BE COATED W/ AN ASPHALT COATING. /

LA PARTE DI TUTTI GRADINI INCORPORATI NEL CALCESTRUZZO DEVE ESSERE RIVESTITA

CON UN RIVESTIMENTO D'ASFALTO.

ENCAPSULATED STEEL STEP / GRADINO IN ACCIAIO INCAPSULATO

BB

MACH

A A

6203820

93250

25 25560

125600125

38 SQ X 9 DEEP /

QUADRATO LARGO

38 PER 9 DI

MACH (TYP)

SECTION A-A / SEZIONE A-A

COVER - BOTTOM VIEW /

VISTA INFERIORE - COPERCHIO

70X38 SLOTS UNLESS SPECIFIED OTHERWISE /

FESSURE 70X38 SE NON DIVERSAMENTE SPECIFICATO

COVER - TOP VIEW /

VISTA SUPERIORE - COPERCHIO

MINIMUM WEIGHT CAST IRON FRAME 225 LBS. COVER 125 LBS. /

ALTEZZA MINIMA TELAIO IN FERRO BATTUTO 225 LBS. COPERCHIO 125 LBS.

MINIMUM LOAD RATING AASHTO H-20; DIN 19580 CLASS D /

PORTATA MINIMA DI CARICO AASHTO H-20; DIN 19580 CLASSIFICAZIONE D

SECTION B-B / SEZIONE B-B

FRAME / TELAIO

PLAN / PIANTA

NOTE / NOTA:

SEE SPECIFICATIONS FOR IDENTIFICATION MARKINGS TO BE

CAST IN TOP OF COVER. MARKINGS TO BE RAISED 10. /

VEDERE LE SPECIFICHE PER LE MARCATURE DI

IDENTIFICAZIONE CHE DEVONO ESSERE FUSE NELLA PARTE

SUPERIORE DEL COPERCHIO. MARCATURE DA SOLLEVARE DI 10.

A1 CLEANOUT/POZZETTO DI ISPEZIONE

NO SCALE / NON IN SCALA

A2 DROP INLET/INGRESSO BASSO

NO SCALE / NON IN SCALA A4 GRAVITY SEWER WYE CONNECTION/CONNESSIONE AD Y A GRAVITA'

NO SCALE / NON IN SCALA

C2 MANHOLE STEP/GRADINO POZZETTO

NO SCALE / NON IN SCALA

CONCRETE / CALCESTRUZZOWYE / RACCORDO A Y

100 MIN

100100

VA

RI

ES

/ V

AR

IA

BI

LE

CAST IRON CLEANOUT COVER

AND PLUG / TUBO DI SCARICO

IN GHISA CON COPERCHIO

FINISHED GRADE /

PIANO FINITO

0 M

IN

450 SQUARE

QUADRATO LARGO 450

CONCRETE /

CALCESTRUZZO SIZE AS INDICATED /

MISURA COME INDICATO

TOP OF BELL /

SOMMITA'

POZZETTO

CONCRETE BLOCK MIN WIDTH OD +300 /

BLOCCO IN CLACESTRUZZO LARGHEZZA OD +300

PLUG IF AT END OF LINE /

TAPPARE SE ALLA FINE DELLA

LINEA DI CONDOTTA

8"

5 S

Q

D

D

CC

COLLAR DETAIL / DETAGLIO COLLARE

13X38X100

SECTION D-D / SEZIONE D-D

SECTION C-C / SEZIONE C-C

SECTION B-B / SEZIONE B-B

BB

150 (TYP)

VA

RI

ES

/ V

AR

IA

BI

LE

PROFILE / PROFILO

#13@100 EACH WAY /

#13@100 CIASCUNO

MODO

#13 DIAGONAL @ ALL CORNERS TYP

#13 DIAGONALE SU TUTTI GLI

ANGOLI TIPICO

WHEN INDICATED

SHAPE INVERT IN /

QUANDO INDICATO,

INVERTIRE FORMA

VERSO L'INTERNO

PRECAST

BASE

UNIT

200 BEDDING MATERIAL /

200 MATERIALE DI POSA

25 CLR TYP 125 FOR 1200 DIAMETER

150 FOR 1800 DIAMETER /

125 PER 1200 DIAMETRO

150 PER 1800 DIAMETRO

(A

DD

R

IS

ER

U

NI

TS

A S

NE

ED

ED

(A

GG

IU

NG

ER

E

UN

IT

A

DI

R

IS

AL

IT

A

SE

CO

ND

O

NE

CE

SS

IT

A'

LUGS CAST W/ COLLAR /

ALETTE FUSE CON COLLARE

CI COLLAR /

COLLARE IN

GHISA

MIN WEIGHT / PESO MINIMO:

COLLAR & LUGS / COLLARE E ALETTA: 63 LB

GRATE/GRATA: 354 LB

PRECAST TOP UNIT /

UNITÀ SUPERIORE PREFABBRICATA

LONG RADIUS BEND /

CURVATURA A LUNGO

RAGGIO

BEDDING MATERIAL /

MATERIALE LETTO DI POSA

LATERAL PIPE /

TUBO LATERALE

SUITABLE BACKFILL MATERIAL /

MATERIALE DI RIEMPIMENTO

ADATTO

45° BEND /

CURVATURA

75 MIN

CONCRETE /

CALCESTRUZZO

WYE BRANCH

/RAMO RACCORDO

TUBO A Y

MAIN

/PRINCIPALE

BEDDING MATERIAL

/ MATERIALE LETTO DI POSA

200 MIN

75 MIN 75 MIN

CONCRETE /

CALCESTRUZZO

FLOW /

FLUSSO

SUITABLE BACKFILL MATERIAL/

MATERIALE DI RIEMPIMENTO ADATTO

MAIN /

TUBAZIONE

PRINCIPALE

BEDDING MATERIAL FULL LENGTH OF WYE

/ MATERIALE DI POSA PER TUTTA LA

LUNGHEZZA DEL RACCORDO TUBO A Y

45° BEND / CURVATURA A 45°

LATERAL PIPE /

TUBO LATERALE

VERT ANGLE 45° MAX /

ANGOLO VERTICALE 45° MAX

WYE BRANCH / RAMO

RACCORDO TUBO A Y

BEDDING MATERIAL / MATERIALE LETTO

WHERE VERT ANGLE EXCEEDS 45°, CONN

SHALL BE CONC ENCASED. / DOVE L'ANGOLO

VERTICALE SUPERA I 45°, IL CONNETTORE

DEVE ESSERE INCASSATO NEL CALCESTRUZZO

STANDARD CONNECTION VERTICAL

ANGLE 45° MAX. / CONNESSIONE

STANDARD ANGOLO VERTICALE 45°MAX

VERTICAL CONNECTION / CONNESSIONE VERTICALE

C4 MANHOLE FRAME AND COVER

NON IN SCALA

NO SCALE

TELAIO E COPERCHIO POZZETTO

B2

CU101D

VA

RI

ES

0 M

IN

VA

RI

A

0 M

IN

1200 (MIN UNO, NOTE 2) /

1200 (MIN UNO, NOTA 2)

600 DIA, MIN

NOTE / NOTA:

1. PROVIDE REINFORCEMENT AS DESIGNED BY MANUFACTURER. / FORNIRE RINFORZO COME PROGETTATO DAL

PRODUTTORE.

2. PROVIDE MANHOLE DIAMETER AS REQUIRED BY PRECAST MANUFACTURER TO ACCOMMODATE PIPING. / FORNIRE IL DIAMETRO DEI POZZETTI COME RICHIESTO DAL PRODUTTORE PREFABBRICATO PER ALLOGGIARE

LE TUBAZIONI.

3. PROVIDE PRECAST MANHOLE FOR D400 LOADING, UNO. / FORNISCONO PASSO PRECAST PER IL

CARICAMENTO D400, UNO.

4. REINFORCEMENT ACCORDING TO PRECAST MANUFACTURER (REINFORCEMENT NOT SHOWN). / RINFORZO

SECONDO PRODUTTORE PREFABBRICATO (RINFORZO NON MOSTRATO).

5. PIPE PENETRATIONS MUST BE FRAMED BY THE PRECAST MANUFACTURER OR CORE DRILLED IN THE FIELD. / LE PENETRAZIONI DEI TUBI DEVONO ESSERE INCORPORATE DAL FABBRICANTE PRECAST O FORATE NEL

CAMPO.

6. WATER TABLE IS SHALLOW. PROVIDE MANUFACTURER CALCULATED BUOYANCY ANALYSIS FOR ALL BELOW GRADE STRUCTURES. STRUCTURES MUST BE SUFFICIENTLY ANCHORED TO PREVENT FLOATATION. / LA TABELLA DELLACQUA E BASSA. FORNIRE UNANALISI DI GALLEGGIAMENTO CALCOLATA AL PRODUTTORE PER

TUTTE LE STRUTTURE DI GRADO INFERIORE. LE STRUTTURE DEVONO ESSERE ANCORATE

SUFFICIENTEMENTE PER EVITARE IL GALLEGGIAMENTO.

MH FRAME & COVER /

TELAIO E COPERCHIO CHIUSINO

GROUT IN PLACE (USE 89

AHR BOLTS TO BOLT IN

PLACE FOR WATERTIGHT

MH COVERS) / RIEMPIRE A

POSTO (UTILIZZARE 89

BULLONI AHR DA ESTRARRE

IN POSIZIONE PER

COPERTURE MH STAGNE)

TAPER SECTION /

SEZIONE CONICA

SP

AC

ER

S

DI

ST

AN

ZI

AL

I

RISER SECTION /

SEZIONE DI

ALZATA

VA

RI

ES

VA

RI

A

VA

RI

ES

VA

RI

A

0 BASE SECTION /

SEZIONE DI BASE

SHAPE INVERT /

FORMARE IL

INVERTITO

150 (TYP)

200 BEDDING MATERIAL /

200 MATERIALE DA LETTO

C1 PRECAST STORM/SANITARY MANHOLE NO SCALE / NON IN SCALA

POZZETTO PLUVIALE/SANITARIO PREFABBRICATO

A2

CU101S

C1 C-503

C1 C-503

D4

CU106D

A1

CU101S

VARIES /

VARABILE

La st s av ed b y:

W

IS

EM

AN

M

(2

1-

P lo tte d:

1-

-2

Fi le na m e:

L :\D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\C

\1

-C -5

-1

4.

D

W G

La st s av ed b y:

W

IS

EM

AN

M

(2

1-

P lo tte d:

1-

-2

Fi le na m e:

L :\D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\C

\1

-C -5

-1

4.

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

DRAWFORM REVISION: 20 AUGUST 2020

AS NOTED

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

C-503

CI

VI

L D

ET

AI

LS

DE

TT

AG

LI

CI

NOTES/ NOTE:

1. PROVIDE RECESS ACCESS FRAME AND COVER PER LANDSCAPE DETAILS WHEN STRUCTURE OCCURS IN PAVER AREAS. /

FORNITURA E POSA IN OPERA DI TELAIO E COPERCHIO INCASSATO PER SISTEMAZIONE A VERDE QUANDO I POZZETTI

SONO IN AREE PAVIMENTATE

2. BACKFILL MATERIAL SHALL BE CRUSHED STONE MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED BY ASTM D2321. / IL MATERIALE DI RIEMPIMENTO DOVRA' SODDISFARE I REQUISITI DEI MATERIALI DI CLASSE II DEFINITI DA

ASTM D2321

3. BEDDING AND BACKFILL SHALL BE PLACED AND COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. / RINTERRO E COSTIPAMENTO DOVRANNO ESSERE POSATI E COMPATTATI UNIFORMEMENTE IN ACCORDO CON ASTM D2321

4. DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212. / LA RESISTENZA DELLA

CONNESSIONE DEI DRENAGGI DOVRA' ESSERE CONFORME A ASTM D3212

5. DETAIL SHOWS TYPICAL DRAIN BASIN CONFIGURATION. REFER TO MANUFACTURER FOR INLINE DRAIN CONFIGURATIONS AND REQUIREMENTS. SUBMIT DRAIN BASIN PRODUCT DATA FOR ACCEPTANCE. / I PARTICOLARI TIPICI DEI POZZETTI DI DRENAGGIO. FANNO RIFERIMENTO ALLA PRODUZIONE DELLA DITTA INLINE DRENAGGI, CONFIGURAZIONI E REQUISIT.

INVIARE I DATI DEL PRODOTTO DEL BACINO DI SCARICO PER L'ACCETTAZIONE.

6. SEE CU600-SERIES SHEETS FOR STRUCTURE TABLE. SMALLER DIAMETER RISERS ARE PERMISSIBLE WHERE CONNECTING PIPE DIAMETERS ALLOW./ VEDERE TAVOLE SERIE CU-600 PER LE TAVOLE STRUTTURALI. SONO AMMESSE

ALZATE DI DIAMETRO INFERIORE SE I DIAMETRI DEL TUBO DI RACCORDO CONSENTONO

IN LOADBEARING AREAS (FIRE LANES AND PAVED SURFACES) PROVIDE RECESSED CONCRETE COLLAR AS SHOWN. FOR PAVER AREAS: PROVIDE RECESSED ACCESS COVER (SEE LANDSCAPE DETAILS).

MINIMUM LOAD RATING AASHTO H-20; DIN 19580 CLASS D /

NELLE AREE DI CARICO PESANTE (CORSIA VVF E AREE PAVIMENTATE) PREVEDERE COLLARI INCASSATI IN CLS COME INDICATO. PER AREE PAVER: FORNIRE UN COPERCHIO DI ACCESSO INCASSO (VEDI DETTAGLI DEL PAESAGGIO). PORTATA MINIMA DI CARICO AASHTO H-20; DIN 19580 CLASSIFICAZIONE D

SEE LANDSCAPE FOR MATERIAL INFORMATION AND DETAILS/ VEDERE SISTEMAZIONE A VERDE

PER INFORMAZIONI SUI MATERAILI E PARTICOLARI

INJECTION MOLDED

WATER-TIGHT TEE/

INNESTO STAMPATO A "T"

RESISTETE ALL'ACQUA

INSERT INJECTION MOLDED,

GASKETED SPIGOT BY

BELL REDUCER/

INSERTO STAMPATO AD INIEZIONE,

GUARNIZIONE SPIGOT E RIDUTTORE A CAMPANA

FINISH GRADE/TERRENO FINITO

DRAINAGE SYSTEM/

SISTEMA DI DRENAGGIO

DOWNSPOUT CONNECTION FROM

DOWNSPOUT BOOT TO DRAINAGE

SYSTEM (SEE NOTES)/

CONNESSIONE AL PARASPRUZZI AL

SISTEMA DI DRENAGGIO (VEDERE

NOTA)

NOTES:

1. FOR DOWNSPOUT CONNECTIONS (UNO): /

PER LE CONNESSIONE AL PARASPRUZZI

MINIMUM SIZE = 150mm / DIM. MINIMA =150MM

MINIMUM SLOPE = 1% / PENDENZA MIN. =1%

MATERIAL = PVC / MATERIALE = PVC

MINIMUM COVER: 600mm (TRAFFIC AREAS), 300mm (YARD AREAS)/

COPERTURA MIN.: 600MM (AREA CON TRAFFICO), 300MM (CORTILI)

2. SEE PLUMBING AND ARCHITECTURAL SHEETS FOR ROOF DOWNSPOUT LOCATION,

SIZE, AND CONTINUATION. / VEDERE TAVOLE IMPIANTO IDRICO-SANITARIO E

ARCHITETTONICHE PER LA POSIZIONE, LA DIMENSIONE E LA CONTINUAZIONE DEL

PARASPRUZZI

MI

N

DE

PT

H (S

EE

N

OT

ES

PR

OF

ON

DI

TA

' M

IN

(V

ED

ER

E

NO

TA

) FINISH GRADE IN NON-LOADBEARING AREAS/

TERRENO NATURALE NELLE AREE NON DI CARICO

PVC STORM DRAIN LINE/

LINEA DI DRENAGGIO IN PVC

150 SUMP/

SIFONE

VA

RI

AB

LE

D

EP

TH

SE

E

PR

OF

ILE

S

INTEGRATED DUCTILE IRON FRAME AND GRATE PER ASTM A536, GRADE

70-50-05; (SEE STRUCTURE TABLE FOR RISER DIAMETER AND GRATE TYPE)/

COPERCHIO E TELAIO INTEGRATO IN GHISA ASTM A536, CLASSE 70-50-05

(VEDERE TAVOLA STRUTTURALE PER SPESSORE E TIPO DI GRIGLIA)

#57 BACKFILL MATERIAL/

MATERIALE DI RIEMPIMENTO

750 (SEE NOTES)/

(VEDERE NOTE)

100 MIN

PVC DRAIN BASIN

RISER (TYP)/

SCARICO IN PVC

INCASSATO (TIP.)

SUBGRADE, LIME STABILIZED /

300 AGGREGATE BASE/

PARTIAL SECTION A /SEZIONE PARZIALE A

LC

450 (MIN)

SAWCUT PAVEMENT /

PAVIMENTAZIONE TAGLIATA A SEGA

150 (MIN)

1:1

EXISTING PAVEMENT SUBGRADE /

SOTTOFONDO DELLA PAVIMENTAZIONE ESISTENTE

COMPACTED SUBGRADE /

SOTTOFONDO COMPATTATO

NOTES/NOTA:

1. SEALANT AT ASPHALT PAVEMENT ISOLATION JOINT: ASTM D6690, HOT-POUR ASPHALT BASED, SELF LEVELING, AND FLUSH WITH PAVEMENT. / SIGILLANTE PER GLUNTO DI ISOLAMENTO

PAVIMENTAZIONE IN ASFALTO: ASTM D6690, BASE IN ASFALTO CALDO, LIVELLAMENTO E

COLARE CON IL PAVIMENTO

B2 PVC DRAIN BASIN/POZZETTO DI DRENAGGIO

NO SCALE

100 MIN

150 MIN

D

EP

TH

VA

R

IE

S/

PR

O

FO

N D

IT

A'

VA

R

IA

BI

LE

(MIN)

8% (TYP)8% (TYP)

NOTES:

1. TIE BARS ARE REQUIRED BETWEEN VALLEY GUTTER AND CONCRETE PAVEMENT ONLY FOR COLD JOINTS - TIE BARS ARE NOT REQUIRED WHEN PAVEMENT AND GUTTER ARE INTEGRALLY POURED. TIE BARS SHALL BE ASTM A615 GRADE 60, #M13 x 600mm LONG TIE BARS, 750mm ON CENTER, AND 150mm MINIMUM FROM CONTROL JOINTS. / I CONNETTORI SONO RICHIESTI VICINO AL TERMINALE DELLA CANALETTA ED I CONNETTORI PER I GIUNTI FREDDI NON SONO NECESSARI QUANDO LA PAVIMENTAZIONE E LA CANALETTA SONO INTEGRATI. I CONNETTORI DOVRANNO ESSERE SECONDO ASTM A615 SERIE 60, #M13x600MM LUNGO LE BARRE, 750MM AL

CENTRO E 150MM MINIMO PER GIUNTI DI CONTROLLO

2. COMPACT SUBGRADE AND AGGREGATE BASE TO 95% ASTM D1557 (MINIMUM)./ COMPATTARE IL FONDO E

L'AGGREGATO DI BASE AL 95% PER ASTM D 1557 (MIN)

3. PROVIDE SMOOTH RADIUS AT FLOWLINE./ FORNITURA E POSA IN OPERA DI RAGGIO LISCIO ALLA LINEA DI

FLUSSO

PVMT

500 500

COMPACTED SUBGRADE /

SOTTOFONDO COMPATTATO

30 MPa CONC (MIN)

AGGREGATE BASE /

AGGREGATO DI BASE

PVMT

0 (

MI

N)

TIE BAR

(SEE NOTE 1)/

CONNETTORI

(VEDERE NOTA 1)

EQ

EQ

D

E

A

B

FC

KEY:

A. NEW ASPHALT SURFACE COURSE / NUOVO STRATO DI ASFALTO

B. NEW ASPHALT BASE COURSE / NUOVO STRATO DI BASE

C. NEW AGGREGATE BASE COURSE / NUOVO AGGREGATO DI BASE

D. EXISTING ASPHALT SURFACE COURSE / STRATO DI ASFALTO ESISTENTE

E. EXISTING ASPHALT BASE COURSE / STRATO DI BASE ESISTENTE

F. EXISTING AGGREGATE BASE COURSE / AGGREGATO DI BASE ESISTENTE

G. CONCRETE PAVEMENT ISOLATION JOINT (SEE DETAIL) /

GIUNTO DI ISOLAMENTO PAVIMENTAZIONE IN CLS /VEDERE PARTICOLARE)

H. CONCRETE VALLEY GUTTER (SEE DETAIL) / TERMINALE CANALETTA IN CLS (VEDERE

PARTICOLARE)

G

H

A2 TERMINALE CANALETTA CON PAVIMENTAZIONE ESISTENTE

NO SCALE / NON IN SCALE

A1 TERMINALE I CLS CANALETTA

NO SCALE/NON IN SCALA

1/2 ENTRACE WIDTH/

1/2LARGHEZZA ENTRATA

NOTE/NOTA:

ENTRANCE SYMMETRICAL ABOUT CENTERLINE /

ENTRATA SIMMETRICA ALLA LINEA DI ASSE

D D

EE

FF

FLOW LINE/DIREZIONE FLUSSO

C

C

ROADWAY/ STRADA

A3 CONCRETE ENTRANCE / ACCESSO IN CLS

NO SCALE

FOR SIDEWALK, CURB & GUTTER

BUILT INTEGRALLY

PER MARCIAPIEDI, CORDOLI E CANALETTE

COSTRUZIONE INTEGRATA

SECTION ELEVATION @ GUTTER LINE / PROSPETTO SEZIONE SULLA CANALETTA

HALF PLAN / PIANTA PARZIALE

SECTION C / SEZIONE C

SECTION F / SEZIONE FSECTION E / SEZIONE E SECTION D / SECTION D

VARIES/ VARIABILE

CURB WIDTH /

LARGHEZZA CORDOLO

VA

RI

ES

/V

AR

225 300 300

GU

TT

ER

W

ID

TH

LA

RG

HE

ZZ

A

CA

NA

LE

TT

A

SEE PLANS/

VEDERE PIANTA

CU

RB

W

ID

TH

LA

RG

HE

ZZ

A

CO

RD

OL

O

A5 TUBO PERFORATO DRENAGGIO COPERTURA

NO SCALE/ NON IN SCALA

0 (

MI

N)

DI

A

TRENCH WIDTH/

LARGHEZZA SCAVO

A

C

B

KEY:

A. DRAINAGE GEOTEXTILE / TESSUTO GEOTESSILE DRANANTE

B. PERFORATED ROOF DRAIN SYSTEM PIPE, 200mm (MIN), UNO. /

SISTEMA DI DRENAGGIO CON TUBO PERFORATO 200MM (MIN)

C. OPEN-GRADED STONE: AASHTO M43 #57 /PIETRA POROSA

AASHTO M 43#57

D. TRENCH WIDTH AND BACKFILL PER SEE TRENCH DETAIL (DET C3,

SH C-510) / PER LARGHEZZA SCAVO E RIEMPIMENTO VEDERE

PARTICOLARI SCAVO (PARTICOLARE C3 SU TAV. C-C510)

E. FINISH GRADE / TERRENO NATURALE

F. MINIMUM COVER: 600mm (TRAFFIC AREAS), 300mm (YARD

AREAS) /COPRTURA MINIMA: 600MM (AREA TRAFFICATE), 300MM

(AREE CORTILI)

NOTE/NOTA:

1. OVERLAP GEOTEXTILE 300 (MIN) OR AS RECOMMENDED BY

MANUFACTURER, WHICHEVER IS GREATER. /

LA SOVRAPPOSIZIONE MINIMA DEL TESSUTO GEOTESSILE E' DI

300 MIN. RACCOMANDATA DAL PRODUTTORE, ACCETTABILI DIM.

MAGGIORI

D

E

MI

NI

MU

M

CO

VE

R/

CO

PE

RT

UR

A

MI

NI

MAF

200 THICK

CONCRETE #13 @ 300 EACH WAY

(M

IN

CONCRETE TURN DOWN, ALL EDGES /

RIBASSAMENTO DEL CALCESTRUZZO, SU

TUTTI I BORDI

PLAN /PIANTA

C4 DUMPSTER PAD/ BASAMENTO CASSONETTI

NO SCALE/NON IN SCALA

C1 ROOF DOWNSPOUT CONNECTION

NON IN SCALA

NO SCALE

CONNESSIONE AL PARASPUZZI DEL TETTO

INJECTION MOLDED

WATER-TIGHT TEE (TYP)/

INNESTO STAMPATO A "T"

RESISTETE ALL'ACQUA (TIP)

PVC STORM DRAIN LINE/

LINEA DI DRENAGGIO IN PVC

PR

OF

ON

DI

TA

' V

AR

IA

BI

LE

VE

DE

RE

P

RO

FI

LI

1/2" PREMOLDED EJ FILLER/

2" GIUNTO DI ESPANSIONE

PREFORMATO

1/2" PREMOLDED EJ FILLER/

2" GIUNTO DI ESPANSIONE

PREFORMATO

STRATO DI BASE AGGREGATO

SOTTOFONDO, STABILIZZAZIONE DELLA CALCE

PERFORATED ROOF DRAIN

VALLEY GUTTER TRANSITION @ EXISTING PAVEMENT

CONCRETE VALLEY GUTTER

FLUSH WITH VALLEY GUTTER, SEE DETAIL A1/C-504

A FILO CON LA GRONDAIA, VEDI DETTAGLIO A1/C-504

PROVIDE CONTRACTION

JOINTS AT 3m OC (MAX) /

PREVEDERE GIUNTI DI

CONTRAZIONE AL CENTRO

OGNI 3 M (MAX)

WASTE CONTAINTERS (BY OTHERS).

QUANTITY OF CONTAINERS MAY VARY /

CONTENITORI RIFIUTI (FUORI CONTRATTO).

LA QUANTITA DI CONTENITORI PUO VARIARE

TURN DOWN CURB/

CORDOLO RIBASSATO

1% (T

YP

A

A

B2

CU101D

B2

CU101D

B1

CS102

B1

CS102 D4

CS103

A2

CU101D

La st s av ed b y:

W

IS

EM

AN

M

(2

1-

P lo tte d:

1-

-2

Fi le na m e:

L :\D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\C

\1

-C -5

-1

4.

D

W G

La st s av ed b y:

W

IS

EM

AN

M

(2

1-

P lo tte d:

1-

-2

Fi le na m e:

L :\D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\C

\1

-C -5

-1

4.

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

DRAWFORM REVISION: 20 AUGUST 2020

AS NOTED

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

C-504

CI

VI

L D

ET

AI

LS

DE

TT

AG

LI

CI

(M

IN

EQ

(M

IN

EQ

B1 RECINZIONE DI SICUREZZA

NO SCALE/NON IN SCALA

IMPACT CABLES/

CAVI D'IMPATTO

CHAIN-LINK SECURITY FENCE

NOTE: PROVIDE SIGNS AT CORNERS AND AT EVERY 30m (MINIMUM) ALONG FENCE.

SIGNAGE STYLE MUST MATCH "RESTRICTED AREA" STYLE IN "AR 190-13", CHAPTER 6-7

AND YELLOW ITALIAN RESTRICTED AREA SIGNAGE. /

NOTA: FORNIRE SEGNALI AGLI ANGOLI E A OGNI 30 m (MINIMO) RECINTO. LO STILE DI

SEGNALAZIONE DEVE CORRISPONDERE ALL'AREA "AREA RISERVATA" LO STILE DI "AR

190-13", CAPITOLO 6-7 E IL SEGNALE DELL'AREA ITALIANA RISERVATA SULLA ZONA.

PRIVACY SCREEN (TYPICAL) /

SCHERMO VERDE (TIPICO)

PRIVACY SCREEN (TYPICAL) /

SCHERMO VERDE (TIPICO)

2400 (3000 MAX)

400 DIA

2400 (3000 MAX)

FRONT ELEVATION SIDE ELEVATION

LINE POST/

MONTANTE DI LINEA

CONTINUOUS TOP RAIL/

TUBO SUPERIOIRE CONTINUO

MIDDLE RAIL/

MONTANTE CENTRALE

CORNER OR

TERMINAL POST/

PALO D'ANGOLO

O TERMINALE

TRUSS ROD & TIGHTENER/

BARRA CON TENDITORE

CONC MOWING STRIP SEE DETAIL THIS

SHEET/

FONDAZIONE IN CLS CONTINUA (VEDI

PARTIC. SU QUESTA TAV.)

2" MESH FENCE FABRIC

RETE METALLICA

CONTINUOUS BOTTOM RAIL

SECURE TO CONC MOWING STRIP

SEE DETAIL THIS SHEET /

BARRA CONTINUA DI SICUREZZA

SOPRA LA LINEA DELLA

FONDAZIONE CONTINUA

TYPICAL CORNER OR

TERMINAL POST FOOTING/

FONDAZIONE TIPICA PALO

D'ANGOLO O TERMINALE

TYPICAL LINE POST FOOTING/

FONDAZIONE TIPICA PALO

19 ROUND BY 2400 LONG

COPPER CLAD GROUND ROD/

CORDA DI RAME NUDA PER

MESSA A TERRA 19 DIAM. PER

2400 LUNGHEZZA

#19AWG SOLID COPPER WIRE/

CAVO DI RAME RIGIDO

FINISHED GRADE/

TERRENO FINITO

NOTE / NOTA :

MOWING STRIP TO BE INSTALLED ONLY IN AREAS WHERE FENCE BORDERS

GRASS AREAS. / LA FONDAZIONE CONTINUA DOVRA' ESSERE INSTALLATA NELLE

AREE DOVE LA RECINZIONE DELIMITA LE AREE A PRATO.

PROVIDE PRIVACY SCREEN AND MESH FENCE FABRIC ON PUBLIC SIDE OF FENCE.

PROVIDE SUPPORTING RAILS AND RODS ON SECURE SIDE OF FENCE. / FORNIRE

SCHERMO VERDE E RETE METALLICA SUL LATO PUBBLICO DEL RECINTO. FORNIRE

BINARI E ASTE DI SOSTEGNO SUL LATO SICURO DELLA RECINZIONE.

BRACE RAIL/

CORRENTE DI

RINFORZO

2" MESH FENCE FABRIC

RETE METALLICA

CONTINUOUS TOP RAIL/

TUBO SUPERIOIRE CONTINUO LINE POST/

MONTANTE DI LINEA

CONC MOWING STRIP SEE DETAIL THIS

SHEET/

FONDAZIONE IN CLS CONTINUA (VEDI

PARTIC. SU QUESTA TAV.)

VISTA FRONTALE VISTA LATERALE

BOTTOM RAIL / BARRA INFERIORE

ANCHOR BOTTOM RAIL IN CONCRETE.

SEE DETAIL THIS SHEET /

ANCORARE LA GUIDA INFERIORE NEL

CALCESTRUZZO. VEDI DETTAGLIO

QUESTA TAVOLA

FINISHED GRADE

/ LIVELLO FINITO

25 SLOPE /

PENDENZA 25

FENCE POST / PALO

RECINZIONE

FINISHED GRADE

/ LIVELLO FINITO

900 MOWING STRIP / 900

STRISCIA DI SFALCIO CONC REINFORCED W/ 150x150 W53xW53

WWF AT MIDPOINT OF SLAB /

CALCESTRUZZO RINFORZATO CON

150X100 E W53XW53 MAGLIA METALLICA

AL CENTRO DELLA SOLETTA

FENCE POST FOUNDATION /

FONDAZIONE PALO RECINZIONE

#19 GA. STEEL WIRE / #19

DIAMETRO FILO DI FERRO

PRE-SHAPED TIE WITH

TWISTED END / NODO

PRESAGOMATO CON

OCCHIELLO

TRUSS ROD 9

MIN. / ASTA DEL

TIRANTE 9 MIN

CONC FOOTING /

BASAMENTO IN

CALCESTRUZZO

STRETCHER BAR TO ENGAGE EACH FABRIC LINK /

BARRA TENDITRICE PER AGGANCIARE OGNI RETE

FABRIC / RETE

COILED SPRING WIRE FOR STRETCHING /

FILO A MOLLA ARROTOLATO PER L'ALLUNGAMENTO

STRETCHER BAR BAND TO BE 150 MAX.

FROM TOP & BOT & SPACED @ 350 OC

MAX. / BARRA PER L'ALLUNGAMENTO

DEVE ESSERE 150 MAX DALL'ALTO AL

BASSO E DISTANZIATA IN ASSE

CENTRALE DI 350 MAX

STRETCHER BAR /

BARRA PER L'ALLUNGAMENTO

CARRIAGE BOLT /

BULLONE CARROZZA

TIE WIRE AS SPECIFIED @ 300 O.C.

MAX. / ALLACCIO FILO COME

SPECIFICATO OGNI 300 MAX

TIE TO OCCUR ON SECURE SIDE OF FENCE. / LEGATURA

SUL LATO SICURO DELLA RECINZIONE

FABRIC

/ RETE

3 THICK x 25 WIDE x 450 LONG FLAT GALV. STEEL

STRAP ANCHOR BENT TO SHAPE AS INDICATED.

INSTALL @ 1/3 POINTS BETWEEN FENCE POSTS /

3 SPESSORE x 25 LARGHEZZA x 450 LUNGHEZZA

GALV. ACCIAIO ANCORAGGIO DELLA CINGHIA

PIEGATO IN FORMA COME INDICATO. INSTALLARE

A 1/3 DEI PUNTI TRA I PALI DELLA RECINZIONE

BOTTOM RAIL / BARRA INFERIORE

BOTTOM OF FENCE FABRIC /

BASE RETE DI RECINZIONE

CONC MOWING STRIP / FASCIA DI SFALCO IN CALCESTRUZZO

B4 FENCE FASTENING DETAILS / DETTAGLIO FISSAGGIO RECINZIONE

NO SCALE / NON IN SCALA

D5 CONC MOWING STRIP / STRISCIA DI SFALCIO IN CONC

NO SCALE / NON IN SCALA

BARBED-WIRE APRON ON

EXTENSION ARMS/

FILO SPINATO SU BRACCI

ALLUNGABILI

(T

YP.)

560 190 (TYP.)

35 DEGREES/

45 DEGREES

LOCK PIN (TYP.) BARBED WIRE (TYP.)/

FILO SPINATO (TIP)

10 PLAIN PIN RIVETED FLUSH

(TYP.)/

PERNO DI FISSAGIO RIVETTATO

A FILO (TIP)

LINE POST/ PALO DI LINEA

EXTENSION ARM DETAILS/ PARTICOLARE BRACCI ALLUNGABILI

CORNER POST/ PALO D'ANGOLO

x x x xx x x x x x x x x x x x x x x x x x

4m LEAF/ APERTURA

GATE FRAME/

DROP ROD/PALETTO

CHAIN-LINK

FABRIC

x x x x x x x x x x x x x x x xx x x x x x x x x x x x x x x

LATCH ASSEMBLY/

ASSEMBLAGGIO

9.5 DIA. TRUSS

RODS (TYP)

50 MIN

125 MAX

HINGES (TYP)/

SAND/GRAVEL

150 DIA.

CONCRETE

STANDARD HINGE

GATE KEEPER

(TO HOLD GATE OPEN)

150 DIA.

P.C. CONC.

25 ID

STEEL PIPE/

A

DROP ROD FOUNDATION

LATCH ASSEMBLY

DROP ROD ASSEMBLY

A1 DOUBLE SWING GATE/CANCELLO A DUE ANTE

NO SCALE/NON IN SCALA

x x x xx x x x x

ANGOLO

10 PLAIN PIN RIVETED FLUSH (TYP.)/

PERNO DI FISSAGIO RIVETTATO A

FILO (TIP)

BARBED-WIRE APRON ON EXTENSION ARMS/

FILO SPINATO SU BRACCI ALLUNGABILI

TELAIO CANCELLO

SERRATURA

TENDITORI

RECINZIONE

METALLICA

CERNIERE (TIP)

PAVED SURFACE/

SUPERFICIE

PAVIMENTATA

13 DIA. DROP ROD

(INDUSTRY

STANDARD)/

13 DIAM. TONDINI

(INDUSTRIALE

STANDARD)

BITUMINOUS/

BITUME

TUBO IN ACCIAIO

SABBIA/GHIAIA

PIANTONE CANCELLOFONDAZIONE PALO

ASSEMBLAGGIO CHIUSURA

ASSEMBLAGGIO PALI

(PER APERTURA VECCHI CANCELLI)

B4

CS101

B4

CS101

B1 C-505

PLAN @ BANDS /

PIANTA COLLARI

TRUSS ROD & BAND /TIRANTE DI RINFORZO E COLLARE

CLAMP FOR HORIZ BRACE

ELEV TERMINAL OR GATE POST / PROSPETTO

TERMINE RECINZIONE O PALO CANCELLO BOTTOM RAIL ANCHOR DETAIL /

DETTAGLIO ANCORAGGIO RECIZIONE

INFERIORE

LINE POST ATTACHMENTS / ATTACCO AL PALO RECINZIONE WIRE TIES @ HORIZ BRACE / ALLACCIO

FILI AL SUPPORTO ORIZZONTALEBRACE /

MORSETTO

La st s av ed b y:

W

IS

EM

AN

M

(2

1-

P lo tte d:

1-

-2

Fi le na m e:

L :\D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\C

\1

-C -5

-1

4.

D

W G

La st s av ed b y:

W

IS

EM

AN

M

(2

1-

P lo tte d:

1-

-2

Fi le na m e:

L :\D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\C

\1

-C -5

-1

4.

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

DRAWFORM REVISION: 20 AUGUST 2020

AS NOTED

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

C-505

CI

VI

L D

ET

AI

LS

DE

TT

AG

LI

CI

COMPACTED SOIL/

TERRENO COMPATTATO

FLOW/ FLUSSO

1350 MIN

0 M

IN

CURB INLET/

CURVA DI INGRESSO

CONCRETE BLOCK/

BLOCCO IN CLS

WIRE

SCREEN/

SBARRAMENTO

GRAVEL FILTER (#3, #357 OR #5 COARSE

AGGREGATE)/

FILTRO IN GHIAIA (STRATO DI AGGREGATO

#3,#357 O #5)RUNOFF WATER

WITH SEDIMENT

OVERFLOW/

TROPPOPIENO

FILTERED WATER/

ACQUA FILTRATA

CURB INLET/

CURVA DI INGRESSO50X100 WOOD STUD/

50x10 FERMI IN

LEGNO

SEDIMENT/

SEDIMENTI

WIRE

SCREEN/

SBARRAMENTO SECTION A-A

PLAN VIEW

21000

A

A

ED

GE

O F

EX

IS

TI

NG

RO

AD

W

AY

P

AV

EM

EN

T/

BO

RD

O

DE

LL

A

PA

VI

ME

NT

AZ

IO

NE

ST

RD

AL

E

ES

IS

TE

NT

E

3000 MIN

3000 MIN

3000 MIN

150 THICK LAYER OF COARSE

AGGREGATE (SIZE #1)/

SPESS. DELLO STRATTO DI

AGGREGATO

M

IN

3600 MIN

FILTER CLOTH/

RIVESTIMENTO FILTRANTE

75 MIN

75 MIN

PIANTA

SEZIONE A-A

B

BPLAN

SECTION B-B

SHEET FLOW/

FLUSSO LAMINARE

50X50 MIN WOOD STAKES OR EQUIVALENT

METAL PICKETS @ 1800 OC MIN/

50x50 MIN PALI IN LEGNO O PICCHETTI

METALLICI OGNI 1800 MIN

450 MIN

100 MIN

100 MIN

SHEET FLOW

FLUSSO LAMINARE

EMBED FABRIC IN GROUND/

INTERRARE IL TESSUTO NON TESSUTO

NEL TERRENO

ATTACH FILTER FABRIC TO STAKES/

ATTACCARE IL TESSUTO ALLO

STECCATO

SEZIONE B-B

PIANTA

DROP INLET

WITH GRATE/

DRENAGGIO CON GRATA

SEDIMENT/

SEDIMENTI

WIRE SCREEN/

SCHERMATURA

FILTERED WATER/

ACQUA FILTRATA

WIRE SCREEN/SCHERMATURA

CONCRETE BLOCK/

BLOCCHI IN CLS

GRAVEL FILTER

(#3, #357 OR #5

COARSE AGGREGATE)/

FILTRO IN GHIAIA (STARTO

DI AGGREGATO)

OVERFLOW/

TROPPO PIENO

RUNOFF WATER

WITH SEDIMENT/

ACQUA DI SCARICO CON

SEDIMENTAZIONE

150 TO 300 / 150 A 300

NOTES/NOTE:

APPROXIMATELY 200 STAPLES REQUIRED PER

1200X68580 ROLL ANCHOR SLOTS, JUNCTION SLOTS &

CHECK SLOTS TO BE BURIED 150 TO 300 & VARIABLE/

CIRCA 200 GRAFFE RICHIESTE PER SLOT DI

ANCORAGGIO 1200X68580, SLOT DI GIUNZIONE E DI

CONTROLLO DA INTERRARE DA 150 A 300 & VARIABILE

ANCHOR SLOT /

SCANALATURA DI FONDO

150 TO 300 / 150 A 300

TAMP SOIL FIRMLY / COMPRIMERE

FERMAMENTE IL TERRENO

JUNCTION SLOT / GIUNTO

DELLA SCANALATURA

TAMP SOIL FIRMLY / COMPRIMERE

FERMAMENTE IL TERRENO

ANCHOR SLOT/

SCANALATURA

DI FONDO

JUNCTION SLOT/

GIUNTO DELLA

SCANALATURA

CHECK SLOT / VERIFICA

SCANALATURA

CHECK SLOT/

VERIFICA SCANALATURA

225 MAX. TAMP SOIL FIRMLY / COMPRIMERE

FERMAMENTE IL TERRENO

150 TO 300

/ 150 A 300

TAMP SOIL FIRMLY / COMPRIMERE

FERMAMENTE IL TERRENO

TERMINAL FOLD /

PIEGA TERMINALE

LAP JOINT 50

MIN./ GIUNTO

CERNIERA 50 MIN

COMBINE THIRD ROW OF STAPLES FROM EACH

STRIP IN LAP WITH ALTERNATE SPACING/

COMBINARE LA TERZA FILA DI PUNTI DI OGNI

STRISCIA IN GIRO CON SPAZIATURA ALTERNATA

900 TO 1200 MAX.

/900 A 1200 MAX.

MAX. SPACING C-C CHECK SLOTS/ MAX.

SPAZIATURA C-C FESSURE DI CONTROLLO

30000 SLOPE 4% OR LESS 15000

SLOPE STEEPER THAN 4% / 30000

PENDENZA 4% O A MENO DI 15000

PENDENZA MAGGIORE DEL 4%

25 TO 50 / 25 A 50

150 TO 200 /

150 A 200

STAPLES FORMED FROM NO.8 STEEL WIRE 200 STAPLE MIN. LENGTH FOR SANDY SOIL. 150 STAPLE MIN. LENGTH FOR OTHER SOIL / GRAFFE FORMATE DA N.8 FILI D'ACCIAIO, 200 GRAFFE MIN.

LUNGHEZZA PER TERRENI SABBIOSI. 150 GRAFFE MIN. LUNGHEZZA PER ALTRO TIPO DI TERRENO

A1 DIGA TEMPORANEA

NO SCALE/NON IN SCALA

B1 RECINZIONE LIMO TEMPORANEA

NO SCALE/NON IN SCALA

A2 CURB INLET PROTECTION

NO SCALE

A3 INGRESSO TEMPORANEO DELLA COSTRUZIONE

NO SCALE

B2 INSTALLAZIONE DEL RIVESTIMENTO DI STABILIZZAZIONE DEL TERRENO

NO SCALE

C1 PROTEZIONE GRIGLIA D'ENTRATA

NO SCALE/NON IN SCALA

A4 PROTEZIONE TEMPORANEA ALBERI

NO SCALE

GRATE INLET PROTECTION

TEMPORARY SILT FENCE

TEMPORARY DIVERSION DIKE

SOIL STABILIZATION MAT-INSTALLATION

TEMPORARY CONSTRUCTION ENTRANCE

TEMPORARY CONSTRUCTION ENTRANCE

TEMPORARY TREE PROTECTION

B3

CC101A

A1

CC101A

A3

CC101A

A3

CC102A A1

CC101A

PLAN VIEW STAPLING DIAGRAM JUTE MESH/

VISTA PIANTA DIAGRAMMA GRAFFATURA

MESH JUTA

VARIABLE / VARIABILE

La st s av ed b y:

W

IS

EM

AN

M

(2

1-

P lo tte d:

1-

-2

Fi le na m e:

L :\D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\C

\1

-C -5

-1

4.

D

W G

La st s av ed b y:

W

IS

EM

AN

M

(2

1-

P lo tte d:

1-

-2

Fi le na m e:

L :\D

C S\

PR

O

JE

C

TS

\B

D L\

\9

_C

AD

_G

IS

\9

_C

AD

\2 0-

SH

EE

TS

\C

\1

-C -5

-1

4.

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

DRAWFORM REVISION: 20 AUGUST 2020

AS NOTED

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

C-506

CI

VI

L D

ET

AI

LS

DE

TT

AG

LI

CI

IDENTIFICATION/

IDENTIFICAZIONE

APPROXIMATE

DRAINAGE AREA /

AREA DRENANTE

APPROSSIMATIVE

FIRST-FLUSH VOLUME /

VOLUME ACQUA DA TRATTARE

(MIN REQD)

MAXIMUM FIRST-FLUSH

PEAK FLOW (L/S) /

PICCO MASSIMO DI

PRIMA PIOGGIA

L = LENGTH (m/) /

LUNGHEZZA

H = WATER HEIGHT (m)

(SIDE WATER DEPTH) /

ALTEZZA ACQUA

(PROFONDITA' ACQUA LATERALE)

W = WIDTH (m) /

LARGHEZZA

Y = FREEBOARD (m) /

BORDO LIBERO q1 = ELEV q2 = ELEV q3 = ELEV q4 = ELEV

Ø = PIPE DIAMETER (mm) /

DIAMETRO TUBI

D = PIPE DIAMETER (mm) /

DIAMETRO TUBI

TO OUTFALL /

ALLO SCARICO

STORM DRAIN

(HIGH-FLOW BYPASS)

STORM DRAIN

DRENAGGIO

(FLUSSO IN ENTRATA)

STAINLESS STEEL CLOSING

VALVE WITH FLOAT/

VALVOLA DI CHIUSURA IN

ACCIAIO INOX

FLOW DIVERSION TRUCTURE/

POZZETTO DEVIAZIONE FLUSSO

OIL WATER SEPARATOR COMPLETE WITH SLUDGE SEDIMENTATION TANK, GRAVITY SEPARATOR, AND COALESCENCE

FILTER. PROVIDE CLOSING SECURITY VALVE WITH FLOAT. MAXIMUM FLOW CAPACITY = 4 L/S/OIL WATER SEPARATOR

COMPLETE WITH SLUDGE SEDIMENTATION TANK, GRAVITY SEPARATOR, AND COALESCENCE FILTER. PROVIDE

CLOSING SECURITY VALVE WITH FLOAT. MAXIMUM FLOW CAPACITY = 4 L/S / SEPARATORE ACQUA-OLIO COMPLETO DI

SERBATOIO DI SEDIMENTAZIONE DEI FANGHI, SEPARATORE A GRAVITÀ E FILTRO A COALESCENZA. FORNIRE

CHIUSURA VALVOLA DI SICUREZZA CON GALLEGGIANTE. PORTATA MASSIMA = 4 L/OLIO SEPARATORE ACQUA-OLIO

COMPLETO DI VASCA DI SEDIMENTAZIONE FANGHI, SEPARATORE A GRAVITÀ E FILTRO A COALESCENZA. FORNIRE

VALVOLA DI SICUREZZA VALVOLA DI SICUREZZA CON GALLEGGIANTE. CAPACITÀ MASSIMA DI FLUSSO = 4L/S

PLAN

SECTION B

TREATMENT

INFLOW/

FLUSSO D'ENTRATA

AL TRATTAMENTO

FIRST-FLUSH STORAGE TANK/

SERBATOIO DI STOCCAGGIO

ACQUA DI PRIMA PIOGGIA

HDPE PRESSURE PIPE/

TUBAZIONE PEAD IN PRESSIONE

IP 66 CLOSET WITH COMMAND PANEL AND TIMER CONNECTED TO

RAIN SENSOR. PROVIDE EQUIPMENT PATHWAYS PER ELECTRICAL

SPECIFICATIONS. SEE PLANS FOR LOCATION. /

CHIUSURA IL66 CON PANNELLO COMMANDO E TIMER CONNESSO AL

SENSORE. FORNIRE IL CONDOTTO DELL'ATTREZZATURA SECONDO

LE SPECIFICHE ELETTRICHE. VEDERE PIANI PER LOCALIZZAZIONE.

TO OIL WATER SEPARATOR/

AL SEPARATORE DI OLI

SAND BACKFILL

/ LETTO DI SABBIA

LEAN

CONCRETE/

MAGRONE

SUBMERSIBLE PUMP 0.75 KW WITH CHECK

VALVE AND GATE ON FORCED LINE; DISCHARGE FLOW = 1.5 L/s

/ POMPA SOMMERSA 0,75 KW CON VALVOLA DI CONTROLLO E

CHIUSURA SU LINEA FORZATA,; FLUSSO DI SCARICO =1.5 L/s

H Y

W

800 (MIN)

HEAVY-DUTY FRAME AND COVER (TYPICAL)/

COPERCHIO E TELAIO CARRABILE (TIP.)

1.50 (MIN)

600 (MIN)

B B

SECTION A

PRECAST REINFORCED

CONCRETE STRUCTURE/

STRUTTURA PREFABBRICATA

IN CALCESTRUZZO ARMATO

D

NOTES ABOUT STORMWATER FIRST-FLUSH TREATMENT OPERATING STATION/

NOTE SULLA STAZIONE OPERATIVA PER IL TRATTAMENTO DELL'ACQUA PIOVANA

STORMWATER FIRST-FLUSH INFLOW IN A STORAGE TANK WHERE GRIT AND SLUDGE ARE REMOVED

BY SEDIMENTION.

WHEN STORAGE IS FULL A VALVE WITH FLOAT WILL CLOSE INLET PIPE. WHEN RAIN STOPS A RAIN

SENSOR ACTIVATES A TIMER. AFTER AN ESTABLISHED TIME (24-48 HOURS) PUMP WILL START AND A

CONTINUAL FLOW WILL GO INTO THE OIL WATER SEPARATOR. IF A NEW STORM HAPPENS, RAIN

SENSOR WILL STOP THE PUMP. OIL SEPARATOR HAS INSIDE ANOTHER SLUDGE SEDIMENTATION TANK

AND A GRAVITY SEPARATOR AND COALESCENCE FILTER, FILTER HAS A CLOSING SECURITY VALVE

WITH FLOAT.

WATER TREATED FROM OIL SEPARATOR DISCHARGE INTO AN INSPECTION MANHOLE AND INTO THE

STORM DRAINAGE SYSTEM. STORAGE IS EMPTY AND STATION IS READY FOR ANOTHER CYCLE.

TREATMENT STATION SHALL PROVIDE AN OUTFALL OIL CONCENTRATION LESS THAN 5 MG/LT.

WATER TABLE IS SHALLOW. PROVIDE MANUFACTURER CALCULATED BUOYANCY ANALYSIS FOR ALL

BELOW GRADE STRUCTURES. STRUCTURES MUST BE SUFFICIENTLY ANCHORED TO PREVENT

FLOATATION. /

FLUSSO DELL'ACQUA DI STOCCAGGIO IN UN SERBATOIO DI STOCCAGGIO DOVE LA POLVERE E I

FANGHI SONO RIMOSSI DA SEDIMENTION.

QUANDO LO STOCCAGGIO È PIENO UNA VALVOLA CON GALLEGGIANTE CHIUDERÀ TUBO DI INGRESSO.

QUANDO LA PIOGGIA SI FERMA UN SENSORE DI PIOGGIA ATTIVA UN TIMER. DOPO UN TEMPO

STABILITO (24-48 ORE) SI AVVIA LA POMPA E UN FLUSSO CONTINUO ANDRÀ NEL SEPARATORE DI

ACQUA DELL'OLIO. Se succede una nuova storia, la RAIN SENSOR fermerà la pompa. SEPARATORE DI OLIO

HA ALL'INTERNO DI UN ALTRO SERBATOIO DI SEDIMENTAZIONE FANGHI E UN SEPARATORE DI

GRAVITÀ E COALESCENZA FILTRO, FILTRO HA UNA VALVOLA DI SICUREZZA DI CHIUSURA CON

GALLEGGIANTE.

ACQUA TRATTATA DA SCARICO SEPARATORE OLIO IN UN TOMBINO ISPEZIONE E NEL SISTEMA DI

DRENAGGIO TEMPESTA. LO STOCCAGGIO È VUOTO E LA STAZIONE È PRONTA PER UN ALTRO CICLO.

LA STAZIONE DI TRATTAMENTO DEVE FORNIRE UNA CONCENTRAZIONE DI OLIO IN USCITA INFERIORE

A 5 MG/LT.

LA TABELLA DELLACQUA E BASSA. FORNIRE UNANALISI DI GALLEGGIAMENTO CALCOLATA AL

PRODUTTORE PER TUTTE LE STRUTTURE DI GRADO INFERIORE. LE STRUTTURE DEVONO ESSERE

ANCORATE SUFFICIENTEMENTE PER EVITARE IL GALLEGGIAMENTO.

L

L q1 q2' q4

Ø

A2

TRATTAMENTO ACQUE DI PRIMA PIOGGIA

NO SCALE/NON IN SCALA

OIL WATER SEPARATOR

(OWS)/SEPARATORE DI OLI

q3'

D

SEE PLAN FOR LOCATION/

VEDERE PIANTA PER POSIZIONE)

FINAL MANHOLE/

POZZETTO FINALE

O V

E R

F L O

W

S

T O

R M

D

R A

I N

T R

O P

P O

I E

N O

D

E L

D R

E N

A G

G I O

CONFIGURATION "A"

TO OUTFALL /

ALLO SCARICO

CONFIGURATION "B"

200 PVC PIPE

MINIMUM SLOPE = 0.5%, UNO

STORM DRAIN

(HIGH-FLOW BYPASS)/

DRENAGGIO (BYPASS DI ALTO

FLUSSO)

NOTE: CONFIGURATION "A" SHOWN, THIS VIEW/

NOTA: CONFIGURAZIONE "A" , MOSTRATA SU QUESTA VISTA

q3

A

A

APPROXIMATE ELEVATIONS - SEE STORM PROFILES AND STRUCTURE TABLES /

QUOTE APPROSSIMATIVE - VEDI PROFILI TEMPORALI E TABELLE DELLA STRUTTURA

OIL WATER SEPARATOR (SEE CONFIGURATION "A"

FOR NOTES) / SEPARATORE DI OLI (VEDERE

CONFIGURAZIONE "A" PER LE NOTE).

HDPE PRESSURE PIPE/

TUBAZIONE PEAD IN PRESSIONE

q2

CONFIGURAZIONE "A"

CONFIGURAZIONE "B"

PIANTA

FLOW DIVERSION TRUCTURE/

POZZETTO DEVIAZIONE FLUSSO

SEZIONE A

STAINLESS STEEL CLOSING

VALVE WITH FLOAT/

VALVOLA DI CHIUSURA IN

ACCIAIO INOX

HDPE PRESSURE PIPE/

TUBAZIONE PEAD IN PRESSIONE

OVERFLOW STORM DRAINAGE/

DRENAGGIO DEL TROPPO PIENO

STORMWATER FIRST-FLUSH TREATMENT

SWM7 (NAPOLI /

PADOVA)

10 000 m

60 m

70 L/S 8.0 m

2.0 m

3.8 m 0.9 m 30.6 m NA - CONFIGURATION "B" 300 mm

SWM8 (BOLOGNA)

14 000 m

70 m

70 L/S 9.3 m

2.0 m

3.8 m 0.9 m 31.0 m NA - CONFIGURATION "B" 300 mm

A1

CC101D

28.3 m

28.8 m

26.0 m

26.5 m

28.0 m

28.5 m q1

NOTE / NOTA:

SEE SHEET CU226 FOR q1' AND q2' / VEDERE TAVOLA CU226 PER q1' E q2'

L a s t s a v e d b y

A

D A

T

A M

E Z

D E

L A

G A

R Z

A

L a s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L

C

A D

G

I S

C A

D

S

H E

E T

S C

C

D

W G

L a s t s a v e d b y

A

D A

T

A M

E Z

D E

L A

G A

R Z

A s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L

C

A D

G

I S

C A

D

S

H E

E T

S C

C

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

DRAWFORM REVISION: 20 AUGUST 2020

AS NOTED

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

C-507

C I V

I L

D

E T

A I L S

D E

T T

A G

L I

C

I V

I

A2

POZZETTO DI PRE-TRATTAMENTO (TIPO 1)

NO SCALE / NON IN SCALA

m m

BYPASS / DERIVAZIONE

INV OUT = 300mm HIGHER THAN

BOTTOM OF INFILTRATION BASIN

(SEE PROFILES)

A3

POZZETTO DI PRE-TRATTAMENTO (TIPO 2)

NO SCALE / NON IN SCALA

NOTE/NOTA:

SEE PRECAST STORM MANHOLE DETAILS FOR ADDITIONAL REQUIREMENTS/

VEDERE PARTICOLARI DEL POZZETTO PREFABBRICATO PER REQUISITI AGGIUNTIVI .

m m

TO INFILTRATION BASIN /

AL POZZETTO DI INFILTRAZIONE

INV OUT (SEE PROFILES)

ROOF DRAIN PIPE

INV IN (SEE PROFILES)

BYPASS PIPE OUT, BEYOND WEIR WALL

DERIVAZIONE DEL TUBO IN USCITA VICINO

AL MURO DI SBARRAMENTO

WEEPHOLES TO AGGREGATE

BASE BELOW/ FORI DI DRENAGGIO

AL FONDO IN AGGREGATO

SUMP/SIFONE

INLET STRAINER /FILTRO IN

INGRESSO

WEIR WALL

TOP ELEV = 300mm

HIGHER THAN

BOTTOM OF

INFILTRATION BASIN

ROOF DRAIN PIPE

INV IN (SEE PROFILES)

TO INFILTRATION BASIN /

AL POZZETTO DI INFILTRAZIONE

INV OUT (SEE PROFILES)

WEEPHOLES TO AGGREGATE

BASE BELOW/ FORI DI DRENAGGIO

AL FONDO IN AGGREGATO

SUMP / SIFONE

INLET STRAINER /FILTRO IN

INGRESSO

NOTE/NOTA:

SEE PRECAST STORM MANHOLE DETAILS FOR ADDITIONAL REQUIREMENTS/

VEDERE PARTICOLARI DEL POZZETTO PREFABBRICATO PER REQUISITI AGGIUNTIVI .

PRE-TREATMENT MANHOLE (TYPE 2)PRE-TREATMENT MANHOLE (TYPE 1)

m

V

I

M

BOLOGNA

PADOVA

NAPOLI

B2

/ SCHEMA DEL BACINO DI INFILTRAZIONE - NAPOLI

SCALE / SCALA: 1:100

INFILTRATION BASIN SCHEMATIC - NAPOLI

NOTE/NOTA: REFER TO GENERAL INFILTRATION BASIN NOTES, THIS SHEET. /

FARE RIFERIMENTO ALLE NOTE GENERALI SUL BACINO DI INFILTRAZIONE, SU QUESTA TAVOLA

B4

/ SCHEMA DEL BACINO DI INFILTRAZIONE - BOLOGNA

SCALE: 1:100

INFILTRATION BASIN SCHEMATIC - BOLOGNA

NOTE/NOTA: REFER TO GENERAL INFILTRATION BASIN NOTES, THIS SHEET./

FARE RIFERIMENTO ALLE NOTE GENERALI SUL BACINO DI INFILTRAZIONE, SU QUESTA TAVOLA.

B3

/ SCHEMA DEL BACINO DI INFILTRAZIONE - PADOVA

SCALE / SCALA: 1:100

INFILTRATION BASIN SCHEMATIC - PADOVA

NOTE/NOTA: REFER TO GENERAL INFILTRATION BASIN NOTES, THIS SHEET. /

FARE RIFERIMENTO ALLE NOTE GENERALI SUL BACINO DI INFILTRAZIONE, SU QUESTA TAVOLA.

1. EXCAVATION SHALL EXTEND A MINIMUM OF 600mm OUTSIDE OF ALL MODULAR UNITS.

/ LO SCAVO SI ESTENDE PER UN MINIMO DI 600MM AL DI FUORI DELLE UNITA' MOBILI.

2. MODULAR UNITS ON ENDS SHALL BE TURNED 90° (NOT SHOWN IN SCHEMATIC).

/ LE UNITÀ MODULARI ALLE FINE DEVONO ESSERE RUOTATE DI 90° (NON INDICATE NELLO SCHEMA).

3. THE SCHEMATIC LAYOUT DESIGN USES THE FOLLOWING MODULAR UNIT DATA BASED ON A PARTICULAR MANUFACTURED MODULAR SYSTEM. OTHER MODULAR SYSTEMS ARE ALLOWED. THE

QUANTITY, CONFIGURATION, AND TOP ELEVATIONS OF MODULAR UNITS MAY VARY SLIGHTLY BASED ON THE ACTURAL SYSTEM USED. COORDINATE UNIT LOCATIONS WITH SITE FEATURES AND

UNDERGROUND UTILITIES. SUBMIT PRODUCT DATA AND SHOP DRAWINGS FOR ACCEPTANCE.

/ IL LAYOUT SCHEMATICO UTILIZZA I SEGUENTI DATI UNITARI MODULARI BASATI SU UN PARTICOLARE SISTEMA MODULARE PRODOTTO. ALTRI SISTEMI MODULARI SONO AMMESSI. LA QUANTITÀ, LA

CONFIGURAZIONE E LE ELEVAZIONI SUPERIORI DELLE UNITÀ MODULARI POSSONO VARIARE LEGGERMENTE IN BASE AL SISTEMA ATTUALE UTILIZZATO. COORDINATE I LUOGHI UNITARI CON LE

CARATTERISTICHE DEL SITO E LE UTILITÀ SOTTOGRUPPO. PRESENTA DATI PRODOTTO E DISEGNI NEGOZIO PER L'ACCETTAZIONE

MODULAR UNIT DATA /DATI DELL'UNITA' MODULARE :

3.1. STYLE: SINGLE / STILE : SINGOLO

3.2. DIMENSIONS: WIDTH = 400mm, LENGTH = 715mm, HEIGHT = 440mm / DIMENSIONI LARGHEZZA = 400mm, LUNGHEZZA = 715mm, ALTEZZA = 440mm

3.3. MODULAR UNIT CAPACITY: 125 LITERS / CAPACITA' DELL'UNITA' MODULARE: 125 LITRI

4. INSTALLATION MUST BE PERFORMED BY A MANUFACTURER-CERTIFIED INSTALLER. /L'INSTALLAZIONE DEVE ESSERE EFFETTUATA DA UN IMPIANTO CERTIFICATO DAL FABBRICANTE

= APPROXIMATE LOCATION OF MAINTENANCE PORT. SEE DETAIL A1/C-509. COORDINATE PORT LOCATION WITH SITE FEATURES AND UNDERGROUND UTILITIES./ APPROSSIMATIVA POSIZIONAMENTO

DEL LOCALE DI MANNUTENZIONE . VEDERE DETTAGLIO A1/C-509. COORDINATE LA POSIZIONE DEL POSTO CON LE CARATTERISTICHE DEL SITO E LE UTILITÀ IN SOTTOGRUPPO.

/ NOTE GENERALI PER IL BACINO DI INFILTRAZIONE

GENERAL INFILTRATION BASIN NOTES

INFILTRATION BASIN DATA /

DATI DEL BACINO DI INFILTRAZIONE

LOCATION / LUOGO

MIN VOLUME

/ VOLUME

MINIMO (m

NO. OF UNITS

/ N. DI UNITA'

(NOM)

BOTTOM ELEV /

ELEVAZIONE

SOTTOSTANTE (m)

NAPOLI 90 1130 29.4

PADOVA 30 375 29.4

BOLOGNA 50 630 29.4

B3

CU103D

C2

CU102D

D3

CU101D

I m m m m m m m m m m m m m m m

I

I

I

I m m m m m m m m m m m

M

M

M

M

M

M

M

M

M

M

L a s t s a v e d b y

W

I S

E M

A N

M s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L

C

A D

G

I S

C A

D

S

H E

E T

S C

C

D

W G

L a s t s a v e d b y

W

I S

E M

A N

M s t

P l o t t e d

F i l e n a m e

N

A A

E C

O M

N E

T C

O M

L F

S A

M E

R R

O A

N O

K E

U

S R

N K

D

C S

P

R O

J E

C T

S B

D L

C

A D

G

I S

C A

D

S

H E

E T

S C

C

D

W G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

AR

M Y

FA

M

IL

Y

HO

US

IN

G

P

RO

JE

CT

DRAWFORM REVISION: 20 AUGUST 2020

AS NOTED

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

C-508

C I V

I L

D

E T

A I L S

D E

T T

A G

L I

C

I V

I

MAINTENANCE PORT / PANNELLO DI SERVIZIO

MAINTENANCE PORTS ARE USED TO FLUSH THE SYSTEM. FLUSHING IS

ACHIEVED BY RE-SUSPENSION OF ACCUMULATED SEDIMENT USING

WATER JET EQUIPMENT AND REMOVAL OF SEDIMENT-LADEN WATER

USING PUMPING EQUIPMENT. / I PANNELLI DI MANUTENZIONE SONO

UTILIZZATI PER PULIRE IL SISTEMA. IL RISCIACQUO È OTTENUTO

MEDIANTE RISOSPENSIONE DEL SEDIMENTO ACCUMULATO MEDIANTE

ATTREZZATURE A GETTO D'ACQUA E LA RIMOZIONE DI ACQUA CARICHE

DI SEDIMENTI MEDIANTE APPARECCHIATURE DI POMPAGGIO.

MINIMUM REQUIRED MAINTENANCE INCLUDES A QUARTERLY INSPECTION

DURING THE FIRST YEAR OF OPERATION AND A YEARLY INSPECTION

THEREAFTER. FLUSH SYSTEM AS NEEDED. / LA MANUTENZIONE MINIMA

RICHIESTA COMPRENDE UN'ISPEZIONE TRIMESTRALE DURANTE IL PRIMO

ANNO DI ESERCIZIO E UN'ISPEZIONE ANNUALE IN SEGUITO. SISTEMA DI

PULIZIA COME NECESSARIO.

NOTE/NOTA:

ALL MAINTENANCE PORTS SHALL BE INSTALLED OUTSIDE OF PLAY

FEATURE FALL ZONES. COORDINATE LOCATIONS WITH PLAY EQUIPMENT.

/ TUTTI I PANNELI DI ISPEZIONE DOVRANNO ESSERE INSTALLATI AL DI

FUORI DELLE ZONE DI RICADUTA. COORDINARE IL POSIZIONAMENTO CON

LE ATTREZZATURE DEI GIOCHI.

WHERE IN PAVED AREAS, SET FRAME AND COVER FLUSH WITH FINISHED

SURFACE. / DOVE LE AREE SONO PAVIMENTATE O TRATTATE A VERDE I

TELAI ED I COPERCHI DOVRANNO AVERE UNO SPESSORE RIBASSATO.

WHERE IN PLAY AREAS, SET FRAME AND COVER FLUSH WITH TOP OF

SUBBASE. COVER WITH PLAY SURFACE. / NELLE AREE GIOCHI,

INSTALLARE TELAIO E COPERCHIO CON SPESSORE RIBASSATO CON LA

PARTE SUPERIORE DELLA SOTTOFONDO.

WHERE IN LANDSCAPE PAVER AREAS, PROVIDE RECESSED MANHOLE

COVER PER LANDSCAPE DETAILS. / NELLE AREE PAVIMENTATE E NELLE

AREE A VERDE, FONRIE E PORRE IN OPERA UN COPERCHIO DEL

POZZETTO INCASSATO VEDERE PARTICOLARE SISTEMAZIONE A VERDE.

600 STANDARD FRAME

AND COVER (SEE NOTE) / TELAIO STANDARD 600

E COPERCHIO (VEDI NOTA)

PAVED SURFACE /

SUPERFICIE

PAVIMENTATA

COMPACT BACKFILL TO 95%

PER ASTM D698 / MATERIALE

DI RIEMPIMENTO COMPATTO

AL 95% PER ASTM D698

300 DIA PVC

MAINTENANCE

PORT / PORTA DI

MANUNTENZIONE

IN PVC

DIAMETRO 300

GEOGRID / GEOGRIGLIA

CO

VE

R / C

OP

ER

CH

IO

0 (

MI

N)

(M

AX

PIPE NOTCHING PATTERN

/ SCHEMA DI PUNZONATURA

DEL TUBO

200-HIGH NOTCHES CUT IN

SHADED AREAS (8 TOTAL)

/ TACCHE TAGLIATE IN ZONE

OMBREGGIATE (8 TOTALI)

NON-CORROSIVE HOSE CLAMP / FASCETTA

STRINGITUBO NON CORROSIVA

GEOTEXTILE FABRIC /

TESSUTO GEOTESSILE

NOTCH BOTTOM OF PIPE

SEE PATTERN / INTAGLIO ALLA

BASE DEL TUBO VEDERE IL

MODELLO

NON-CORROSIVE SOLID PLATE.

PLASTIC, SLATE OR EQUIVALENT /

PIASTRA SOLIDA ANTICORROSIVA,

PLASTICA, ARDESIA, O EQUIVALENTE

25 DIA VENT HOLES (32 TOTAL) / FORI DI

VENTILAZIONE DIAMETRO 25 (32 TOT)

FRONT VIEW / VISTA FRONTALE

0.40 kg/sm NON-WOVEN GEOTEXTILE / 0.40 kg/sm TESSUTO NON TESSUTO

PIPE

OD / DIAMETRO

ESTERNO DEL TUBO

PIPE /

TUBO

SIDE VIEW / VISTA LATERALE

PI

PE O.

D.

FABRIC COLLAR SHALL FIT OUTSIDE DIAMETER OF

INLET/OUTLET PIPE / IL COLLARE IN TESSUTO DEVE

ADATTARSI AL DIAMETRO ESTERNO

DEL TUBO DI INGRESSO/USCITA

NOTE: CUT FABRIC AND WRAP AROUND PIPE SO THAT PIPE ABUTS

DIRECTLY AGAINST MODULAR UNITS. PIPE EFFLUENT SHALL NOT BE

OBSTRUCTED BY FABRIC / TAGLIARE IL TESSUTO E AVVOLGERLO

INTORNO AL TUBO IN MODO CHE IL TUBO SI APPOGGI DIRETTAMENTE

CONTRO LE UNITÀ MODULARI. L'EFFLUENTE DEL TUBO NON DEVE ESSERE

OSTRUITO DAL TESSUTO

GEOTEXTILE FABRIC OVER

MODULAR UNITS / TESSUTO

GEOTESSILE SU UNITA' MODULARI

SECTION / SEZIONE

STAINLESS STEEL BANDS

/ BANDE IN ACCIAIO

INOSSIDABILE

STAINLESS STEEL BANDS /

BANDE IN ACCIAIO

INOSSIDABILE

GEOTEXTILE FABRIC / TESSUTO GEOTESSILE

NOTES:

1. COORDINATE MODULAR UNIT SYSTEM WITH FINAL LOCATION OF SITE

FEATURES AND UTILITIES. TOP OF INFILTRATION BASIN MUST BE AT LEAST

500mm BELOW ALL SITE FEATURES AND FOUNDATIONS.

2. INSTALL MODULAR UNITS ACCORDING TO MANUFACTURER'S INSTALLATION

GUIDE. FOLLOW ALL GUIDELINES AND RECOMMENDATIONS.

3. INFLOW MUST BE PRE-TREATED TO PREVENT SEDIMENT ACCUMULATION

IN THE INFILTRATION BASIN. (PRE-TREATMENT STRUCTURES NOT SHOWN

ON THIS DETAIL.)

4. POROUS BACKFILL SHALL BE GRAVEL OR SAND (USCS CLASS GW, GP, SW

OR SP) WITH MAXIMUM STONE SIZE OF 35mm.

5. ENGINEERED FILL MATERIAL SHALL BE CLASSIFIED AS ML, SM, SC, SP.

MAXIMUM STONE SIZE IS 50mm.

6. COMPACT BACKFILL MATERIAL TO 95% PER ASTM D698. LOOSE-LIFT

THICKNESS SHALL NOT EXCEED 200mm.

7. DURING CONSTRUCTION: MAINTAN AT LEAST 300mm OF COVER BETWEEN

EQUIPMENT AND TOP OF THE MODULAR UNIT SYSTEM AT ALL TIMES. FOR

BEST RESULTS, PUSH OUT 350mm TO MAINTAIN THE 300mm MINIMUM.

REFER TO THE MANUFACTURER INSTALLATION GUIDE FOR ACCEPTABLE

EQUIPMENT.

8. PROVIDE GEOGRID WTH FOLLOWING PROPERTIES:

APERTURE DIMENSIONS (NOM): 25mm

TENSILE STRENGTH PER ASTM D6637-10, METHOD A:

· @ 2% STRAIN: 410 kN/m (MARV)

· @ 5% STRAIN: 810 kN/m (MARV)

· ULTIMATE: 1310 MARV kN/m (MARV)

INLET PIPE

CARRYING

PRE-TREATED

STORMWATER /

TUBO D'INGRESSO

CONTENENTE

ACQUA PIOVANA

PRE-TRATTATA 1

PLACE GEOGRID 300mm ABOVE THE MODULAR UNIT SYSTEM. OVERLAP ADJACENT PANELS BY 450mm (MIN). GEOGRID SHALL EXTEND 900mm BEYOND THE EXCAVATION FOOTPRINT. / POSIZIONARE LA GEOGRIGLIA 300MM AL DI SOPRA DEL SISTEMA DI UNITA' MODULARI. SOVRAPPORE I PANNELLI ADIACENTI DI 450MM

(MIN). LA FEOGRIGLIA DEVE ESTENDERSI DI 900MM OLTRE IL PIANO DI SCAVO.

SECTION/SEZIONE

(MIN)

(MIN)

W

L = 715

L = 715

H

0 (

SI

NG

LE

H

0 (

DO

UB

LE

H

0 (

SI

NG

LE

H

0 (

DO

UB

LE

W = 400

MODULE DATA (SINGLE STYLE)

GEOMETRY: LENGTH / LUNGHEZZA (L) = 715mm /GEOMETRIA WIDTH / LARGHEZZA (W) = 400mm

HEIGHT / ALTEZZA (H) = 440mm

STORAGE VOLUME / VOLUME STOCCAGGIO = 125 L

VOID INTERNAL VOLUME / VOLUME VUOTO INTERNO = 95% (NOM)

VOID SURFACE AREA / AREA VUOTO INTERNO = 90% (NOM)

LOAD RATING: 295 kPa (43 PSI), MODULE ONLY /CARCIO HS25 (WITH APPROVED COVER SYSTEM) / 275 kPa (40 PSI), SOLO MODULO

5 (CON SISTEMA DI COPERTURA APPROVATO)

MATERIAL: 85% RECYCLED POLYPROPYLENE (MIN) / 85% POLIPROPILENE RICICLATO (MIN)

/MATERIALE

(SINGLE / SINGOLO)

C1 SISTEMA DI INFILTRAZIONE - UNITÀ MODULARE

NO SCALE

C4 SISTEMA DI INFILTRAZIONE - TUBAZIONE INNESTO A SCARPA

NO SCALE / NON IN SCALA

A1 / SISTEMA DI INFILTRAZIONE - PANNELLI DI ISPEZIONE

NO SCALE A3 / SISTEMA DI INFILTRAZIONE - SEZIONE

NO SCALE

CO

VE

R / C

OP

ER

TU

RA

(M

AX

(M

IN

(M

IN

TO

P

BA

CK

FI

LL

RI

EM

PI

SO

PR

A

0 (

MI

N)

/ NOTE:

1. SISTEMA DI COORDINAZIONE DI UNITÀ MODULARE CON POSIZIONAMENTO

FINALE DIEL SITO,CARATTERISTICHE E LINEE DI SERVIZIO. LA SOMMITA'

DEL POZZETTO DI INFILTRAZIONE DEVE ESSERE ALMENO 500mm SOTTO

TUTTE LE LINEE DI SERVIZIO DEL SITO E LE FONDAZIONI.

2. INSTALALZIONE DI TUTTE LE UNITA' MODULARI IN ACCORDO CON LE

INDICAZIONI DEL COSTRUTTORE. SEGUIRE TUTTE LE INDICAZIONI E LE

RACCOMANDAZIONI.

3. L'AFFLUSSO DEVE ESSERE PRETRATTATO PER EVITARE L'ACCUMULO DI

SEDIMENTI NEL BACINO DI INFILTRAZIONE. (STRUTTURE DI

PRETRATTAMENTO NON MOSTRATE IN QUESTO DETTAGLIO.)

4. IL RINTERRO POROSO DEVE ESSERE GHIAIA O SABBIA (USCS CLASS GW,

GP, SW OR SP) CON PIETRE DI SEZIONE MASSIMA DI 35MM.

5. IL MATERIALE DI RIEMPIMENTO INGEGNERIZZATO DEVE ESSERE

CLASSIFICATO COME ML, SM, SC, SP. DIMENSIONI MASSIME IN PIETRA 50

mm..

6. IL RINTERRO DEVE ESSERE COMPATTATO AL 95% SECONDO ASTM D698.

GLI STRATO NON DOVRANNO ESSERE MAGGIORI DI 200MM.

7. DURANTE LA COSTRUZIONE: MANTENERE ALMENO 300 mm DI COPERTURA

TRA ATTREZZATURE E PARTE SUPERIORE DEL SISTEMA UNITÀ MODULARE

IN TUTTO IL TEMPO. PER MIGLIORI RISULTATI, SCARICARE 350mm PER MANTENERE IL MINIMO DI 300mm. RIFERIMENTO ALLA GUIDA DI

INSTALLAZIONE DEL PRODUTTORE PER ATTREZZATURE ACCETTABILI.

8. FORNITURA E POSA IN OPERA DI GEOGRIGLIA CON LE SEGUENTI

CARATTERISTICHE:

DIMESNIONI DI FORATURA (NOM): 25mm

RESISTENZA ALLA TRAZIONE COME ASTM D6637-10, METODO A:

· @ 2% TRAZIONE: 410 kN/m (MARV)

· @ 5% TRAZIONE: 810 kN/m (MARV)

· ULTIMATE: 1310 MARV kN/m (MARV)

INFILTRATION BASIN - MAINTENANCE…