Attachment H - 1656273dwg18of29.pdf

PDF 28 MB Posted

Attached to
P-91331, Phase 3 Family Housing Villaggio at Vicenza, Italy
Solicitation number
N6247022R0002
Issued by

About this file

This solicitation is for Phase 3 Family Housing at Villaggio at Vicenza, Italy. The Naval Facilities Engineering Command is seeking offers for the construction of additional housing units at the Villaggio housing complex near Vicenza, Italy. Offerors should provide pricing to complete design and construction of approximately 80 family housing units, including site work, utilities, and ancillary facilities. The solicitation number is N6247022R0002. Responses are due by July 18, 2022, and the Navy intends to award a firm fixed-price construction contract by September 2022 to complete the work by December 2024.

View the file

Other files

File Type Posted
Revised Attachment E - Schedule B Price Proposal Form_16JUN2022.pdf PDF
N6247022R0002 Amend 0007.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_16JUN2022.pdf PDF
N6247022R0002 Amend 0007.pdf PDF
Revised Attachment E - Schedule B Price Proposal Form_14JUN2022.pdf PDF
N6247022R0002 Amend 0006.pdf PDF
Attachment Q - Anti-Mafia Self-Certification Form for Contracts between 150000 and 5382000.pdf PDF
Attachment R - Anti-Mafia Self-Certification Form for Contracts greater than 5382000.pdf PDF
N6247022R0002 Amend 0005.pdf PDF
Attachment J - PSC Italian Revised Revised March 18 2022.pdf PDF
Attachment O - 1656273Amend0004 Revised Drawings .pdf PDF
N6247022R0002 Amend 0004.pdf PDF
Attachment P - Site Visit Attendance Log.pdf PDF
Attachment O - 1656273Amend0004 Revised Drawings.pdf PDF
Attachment J - PSC Italian Revised Revised March 24 2022.pdf PDF
Attachment N - 1656273Amend0004 Revised Specs.pdf PDF
Attachment E - Schedule B Price Proposal Form Revised March 24 2022.pdf PDF
N6247022R0002 Amend 0003.pdf PDF
ATTACHMENT M - 1656273Amend0003 Revised Drawings.pdf PDF
ATTACHMENT L - 1656273Amend0003 Revised Specs.pdf PDF
N6247022R0002 Amend 0002.pdf PDF
N6247022R0002 Amend 0001.pdf PDF
N6247022R0002.pdf PDF
Attachment H - 1656273dwg27of29.pdf PDF
Attachment D - Past Performance Questionnaire (PPQ).pdf PDF
Attachment H - 1656273dwg14of29.pdf PDF
Attachment H - 1656273dwg19of29.pdf PDF
Attachment H - 1656273dwg12of29.pdf PDF
Attachment H - 1656273dwg25of29.pdf PDF
Attachment H - 1656273dwg08of29.pdf PDF
Attachment H - 1656273dwg04of29.pdf PDF
Attachment H - 1656273dwg16of29.pdf PDF
Attachment K - DWG Index.pdf PDF
Attachment H - 1656273dwg28of29.pdf PDF
Attachment B - SEC-NAV_5512_1_11787 Form.pdf PDF
Attachment H - 1656273dwg17of29.pdf PDF
Attachment I - UXO Report.pdf PDF
Attachment H - 1656273dwg26of29.pdf PDF
Attachment H - 1656273dwg29of29.pdf PDF
Attachment H - 1656273dwg07of29.pdf PDF
Attachment C - Construction Experience Project Data Sheet.pdf PDF
Attachment H - 1656273dwg15of29.pdf PDF
Attachment H - 1656273dwg23of29.pdf PDF
Attachment E - Schedule B Price Proposal Form.pdf PDF
Attachment H - 1656273dwg20of29.pdf PDF
Attachment F - LRA Commercial Vehicle Inspection Procedures.pdf PDF
Attachment H - 1656273dwg13of29.pdf PDF
Attachment H - 1656273dwg11of29.pdf PDF
Attachment H - 1656273dwg06of29.pdf PDF
Attachment G - Specifications.pdf PDF
Show 40 more

Latest 50 of 61 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AR_GROUND FFL

EL 0

AR_FIRST FFL

EL 3400

AR_SECOND FFL

EL 6800

AR_THIRD FFL

EL 10200

PENTHOUSE

EL 13600

H

D1 A-543X

A1 A-543X

A2 A-543X

5.319

5.12

P04

P04

E

PENTHOUSE

EAVE

EL 17700

EQ

R = 1

EQ

R = 1

EQ

R = 1

EQ

R = 1

EQ

R = 1

10.04 TYP

EW1A

EW1A

8.06

C4 A-543

A3 A-543

B1 A-543

D2 A-543

5.11

P04

P04

P04

P04

P04

P04

P04

P04

EQ

R = 1

EQ

R = 1

EQ

R = 1

GND FFL

3 A

LZ

AT

E

UG

U A

LI

3E Q

RI

SE

RS

FL

T

YP

E

2 / F

L T

IP

O

9.304

9.305

9.306

1:25

0 1.00.5

SCALE:

1.5 2.5

0 421 3 5

SCALE: 1:50

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:2 :2

A M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

A e n ve lo p e .r vt

KLB RBTCMG

A P

B U

IL

D

IN

G

S

TA

IR

S E

C

TI

O N

S A

P E

D

IF

IC

IO

S

E

ZI

O N

E S

C A

LA

A-442

14106330

1656273

C M G

SCALEA-441 1 : 50

B1 A3

STAIR LONG. SECTION /

SEZIONE LONGITUDINALE DELLA SCALA

NOTE CHIAVE DI FOGLIO:

SHEET KEYNOTES /

5.11 PAINTED STEEL WALL MOUNTED HANDRAIL. REFER TO D2 ON SH A-543 /

CORRIMANO IN ACCIAIO VERNICIATO MONTATO A PARETE. VEDI D2 SU TAV

A-543

5.12 PAINTED STEEL RAILING WITH HANDRAIL. REFER TO A1 ON SHEET A-543 /

RINGHIERA IN ACCIAIO VERNICIATO CON CORRIMANO. VEDI A1 SU TAV A-543

5.319 PAINTED STEEL GUARDRAIL AT APARTMENT LANDING. REFER TO B1 ON

SHEET A-543 / RINGHIERA IN ACCIAIO VERNICIATO AL PIANO DI ARRIVO

DELL'APPARTAMENTO. FARE RIFERIMENTO A B1 SULLA SCHEDA A-543.

8.06 1250 X 1250 SMOKE HATCH. REFER TO DETAIL C3 ON SHEET A-525 / BOTOLA

EVACUAZIONE FUMI 1250 x 1250. VEDI DETTAGLIO C3 SULLA TAVOLA A-525

9.304 EXTERIOR TILE FLOORING AT ON GRADE SLABS. REFER TO FLOOR TYPE 10

ON A-604 / PAVIMENTO ESTERNO IN PIASTRELLE ALLE SOLETTE SU TERRA,

FARE RIFERIMENTO A PIANO TIPO 10 SU A-604.

9.305 EXTERIOR GALVANIZED PAINTED HANDRAIL. / CORRIMANO ESTERNO IN

ACCIAIO ZINCATO VERNICIATO.

9.306 EXTERIOR PAVING. REFER TO LS107 / PAVIMENTO ESTERNO. FARE

RIFERIMENTO A LS107.

10.04 INTERIOR STAIRWAY LIFE SAFETY SIGNAGE. REFER TO SHEEET IS601 /

SEGNALETICA DI SICUREZZA INTERNA PER VANO SCALA INTERNO. VEDI TAV

IS601

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SH A-001 & I-001 FOR GEN NOTES, LEGENDS AND SYMBOLS. / FARE

RIFERIMENTO ALLA TAVOLA A-001 & I-001 PER LE NOTE GENERALI, LEGENDE E

SIMBOLI

2. STAIR AND STAIR LANDING CONST IS CAST IN PLACE CONC CONST / LA SCALA ED IL

PIANEROTTOLO SONO REALIZZATI IN CALCESTRUZZO GETTATO IN OPERA

SCALEA-441 1 : 25

C2 A1

AP BUILDING 27100 ENTRY SECT /

AP BLDG 27100 SEZIONE INGRESSO

G

11 12

E

A1 A-443

165 2580 165

0 FFL

P04

P13

P13

P04

B1 A-501

EW2A

9T

0 =

9T

0 =

G

11 12

E

A1 A-443

165 2580 165

3400 FFL

1700 FFL

P04

P13P04

P13

1205 170 1205

EW2A

9T

0 =

9T

0 =

G

11 12

E

A1 A-443

165 2580 165

15 30

1205 170 1205

13600 FFL

11900 FFL

P17

P13

EW2A

P04

EW2A

P13

9T

0 =

9T

0 =

AR_GROUND FFL

AR_SECOND FFL

AR_FIRST FFL

AR_THIRD FFL

10200

AR_PENTHOUSE FFL

13600

TOW

17700

E

10.20 FFL

6.80 FFL

3.40 FFL

0.00

1.70 FFL

17.76 FFL

B1 A-543

C4 A-543

A3 A-543

P04

P04

P04

P04

P17 P04

P04

P04

P04

EQ

R = 1

EQ

R = 1

EQ

R = 1

EQ

R = 1

EQ

R = 1

EQ

R = 1

EQ

R = 1

EQ

R = 1

A. REFER TO SHEET A-001, I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. /

RIFERISI ALLA TAVOLA A-001, I-001 PER NOTE GENERALI, LEGENDE E SIMBOLI

B. STAIR AND STAIR LANDING CONSTRUCTION IS CAST IN PLACE CONCRETE

CONSTRUCTION. / SCALE E PIANEROTTOLI SONO REALIZZATI IN CALCESTRUZZO

GETTATO IN OPERA

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

0 421 3 5

SCALE: 1:50

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:4 :4

A M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

A e n ve lo p e .r vt

KLB RBTCMG

A P

B U

IL

D

IN

G

S

TA

IR

P

LA

N S

A N

D S

E C

TI

O

N A

P E

D

IF

IC

IO

P

IA

N

TA

E

S E

ZI

O

N I S

C A

LA

A-443

14106331

1656273

C M G

SCALEA-111 1 : 50

C3 A2

AP 27200 GROUND STAIR PLAN /

AP 27200 PIANTA SCALA PIANO TERRA

SCALEA-112 1 : 50

C3 A3

FIRST THRU THIRD STAIR PLAN /

PIANTA SCALA PIANO PRIMO A PIANO TERZO

SCALEA-114 1 : 50

C3 C3

PENTHOUSE STAIR PLAN /

PIANTA SCALA ATTICO

SCALEA-112 1 : 50

C3 A1

AP BUILDING 27200 STAIR SECTION /

AP BUILDING 27200 SEZIONE SCALA

20191817161514131211

10 9

DN

70 69 68 67 66 65 64 63 62 61

80797877767574737271

F D

E

A1 A-444

0.000 FFL

P13

242027

295100037801175

12345678

P04

P13

P13 P13

P04

125125

1.700 FFL

EW2A

9T@300 = 2700 1080

9T@300 = 2700

UP

F D

E

A1 A-444

3.400 FFL

1.700 FFL

100037801350

300P04 2122232425262728

P13

P13

P04

P13 P13

EW2A

9T@300 = 2700 1080

9T@300 = 2700

UP

F D

E

A1 A-444

13.600 FFL11.900 FFL

P07

05 300

295100037801210135

P04

2055P13

P04

P13

125125

P13P13

EW2A

9T@300 = 2700 1080

9T@300 = 2700

AR_GROUND FFL

AR_SECOND FFL

AR_FIRST FFL

AR_THIRD FFL

10200

AR_PENTHOUSE FFL

13600

TOW

17700

E

11.90 FFL

8.50 FFL

5.10 FFL

1.70 FFL

17.64

P04

P04

P04 P04

P04

P04

P04

P04

P04

TOP OF ROOF SLAB

13910

B1 A-543

C4 A-543

A3 A-543 34

EQ

R

EQ

R

EQ

R

EQ

R

EQ

R

EQ

R

EQ

R

EQ

R

1. REFER TO SHEET A-001& I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. /

FARE RIFERIMENTO ALLA TAVOLA A-001& I-001 PER LE NOTE GENERALI, LEGENDE E

SIMBOLI.

2. STAIR AND STAIR LANDING CONSTRUCTION IS CAST IN PLACE CONCRETE

CONSTRUCTION. / SCALE E PIANEROTTOLI SONO REALIZZATI IN CALCESTRUZZO

GETTATO IN OPERA.

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

PLAN

NORTH

0 421 3 5

SCALE: 1:50

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:1 :0

P M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

A e n ve lo p e .r vt

KLB RBTCMG

A P

B U

IL

D

IN

G

S

TA

IR

P

LA

N S

A N

D S

E C

TI

O

N A

P E

D

IF

IC

IO

P

IA

N

TA

E

S E

ZI

O

N I S

C A

LA

A-444

14106332

1656273

C M G

SCALEA-121 1 : 50

B2 C3

AP 27300 GROUND STAIR PLAN /

AP 27300 PIANTA SCALE PIANO TERRA

SCALEA-122 1 : 50

B2 B3

FIRST THRU THIRD STAIR PLAN /

PIANTA SCALE DA PIANO PRIMO A PIANO TERZO

SCALEA-124 1 : 50

B2 A3

PENTHOUSE STAIR PLAN /

PIANTA SCALE ATTICO

SCALE 1 : 50 (A-444)

A1

AP 27300 STAIR SECTION /

AP 27300 SEZIONE SCALE

T

W X

A1 A-445

0.000 FFL

J007

STORAGE

J002

FOYER

8E Q

T=

100 2550

800 355

P04

P01

P01 EW1EW1

P01

9E Q

T=

W X

A1 A-445

3.420 FFL

1.800 FFL

165 950 1260

100 2350 100

J101

CIRCULATION

P04 EW1EW1

P01

EW1

C1 A-545

8E Q

T=

9E Q

T=

W X

A1 A-445

1260 950

100 2270 180

J202

CLOSET

5.220 FFL

P04

P01

EW1

P01

P01

J201

CIRCULATION

EW1

6.840 FFL

8E Q

T=

GROUND FFL

SECOND FFL

FIRST FFL

CRAWLSPACE FFL

-540

SE_GROUND TOC

-60

SE_FIRST TOC

SE_SECOND TOC

SE_CRAWLSPACE TOC

-600

B01_AR_BASEMENT 04

B01_AR_BASEMENT 05

B01_AR_BASEMENT 06

21 2224

GARAGE EAVE

3.420 FFL

6.840 FFL

J101

CIRCULATION

J002

FOYER

J201

CIRCULATION

C4 A-545

TYP

A4 A-545

TYP

A2 A-545

TYP

A1 A-545

TYP

EQ

R

9E Q

R = 1

EQ

R = 1

9E Q

R=

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SHEET A-001 & I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS /

FARE RIFERIMENTO ALLA TAVOLA A-001 & I-001 PER NOTE GENERALI, LEGENDE E

SIMBOLI

2. REFER TO FINISH SCHEDULE FOR STAIR FINISH / FARE RIFERIMENTO ALL'ABACO

DELLE FINITURE PER FINITURE DELLE SCALE

3. REFER TO SHEET A-455; A-456; A-457 FOR DETAILS AND A-525 FOR STANDARD

DETAILS / FARE RIFERIMENTO ALLA SCHEDA A-455; A-456; A-457 PER I DETTAGLI E

A-525 PER I DETTAGLI STANDARD

4. REFER TO SHEETS A-445; A-446; A-447 FOR STAIRS IN GENERAL AND A-545 FOR

STAIR DETAILS / FARE RIFERIMENTO ALLE TAVOLE A-455; A-456; A-457 PER LE SCALE

IN GENERALE E ALLA A-545 PER DETTAGLIO DELLE SCALE.

1:25

0 1.00.5

SCALE:

1.5 2.5

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:5 :1

P M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

A e n ve lo p e .r vt

KLB RBTMX

3B R

T O

W N

H O

U S

E S

TA

IR

P

LA

N S

A N

D S

E C

TI

O

N 3B

R T

O W

N H

O U

S E

P

IA

N

TE

E S

E

ZI

O N

I S C

A

LA

A-445

14106333

1656273

M X

SCALEA-431

C2

1 : 25 C3

3BR TH GROUND STAIR PLAN /

TOWNHOUSE 3BR PIANTA SCALA

PIANO TERRA

SCALEA-431

C2

1 : 25 C4

3BR TH FIRST STAIR PLAN /

TOWNHOUSE 3BR PIANTA SCALA

PIANO PRIMO

SCALEA-431

C2

1 : 25 A3

3BR TH SECOND STAIR PLAN /

TOWNHOUSE 3BR PIANTA SCALA PIANO SECONDO

SCALEA-445

D3

1 : 25 A1

3BR TH STAIR SECTION /

TOWNHOUSE 3BR SEZIONE SCALA

F

GH

A1 A-446

950 1340

4859001150100

280 2635

1002435100

1245 900 490

70K007

CLOSET

K006

CIRCULATION

K008

FOYER

0.000 FFL

P02

EW3

P04

EW1

EW3

EW9

EW1

P01 P01

F

GH

A1 A-446

280 2635

325 800 1510

950390950

2.520 FFL

3.420 FFL

P01

P04

P04 P04

EW1 P01

A1

A-551

B1 A-545

C1 A-545

F

GH

A1 A-446

165950390950180

100 2535

6.840 FFL

5.580 FFL P04

P04

P01

P01

280 2635

B1 A-545

SE_GROUND TOC

-60

SE_FIRST TOC

SE_SECOND TOC

GARAGE EAVE

K007

CLOSET

K100

CIRCULATION

K100

CIRCULATION

K208

LINEN

K200

CIRCULATION

K201

BEDROOM

K008

FOYER

5.580 FFL

3.420 FFL

0.000 FFL

2.520 FFL

6.840 FFL

B1 A-545

C4 A-545

A4 A-545

7 E Q

R=

E Q

R=

5 E

Q R=

E

Q R=

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SHEET A-001 & I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS /

FARE RIFERIMENTO ALLA TAVOLA A-001 & I-001 PER NOTE GENERALI, LEGENDE E

SIMBOLI

2. REFER TO FINISH SCHEDULE FOR STAIR FINISH / FARE RIFERIMENTO ALL'ABACO

DELLE FINITURE PER FINITURE DELLE SCALE

3. REFER TO SHEET A-455; A-456; A-457 FOR DETAILS AND A-525 FOR STANDARD

DETAILS / FARE RIFERIMENTO ALLA SCHEDA A-455; A-456; A-457 PER I DETTAGLI E

A-525 PER I DETTAGLI STANDARD

4. REFER TO SHEETS A-445; A-446; A-447 FOR STAIRS IN GENERAL AND A-545 FOR

STAIR DETAILS / FARE RIFERIMENTO ALLE TAVOLE A-455; A-456; A-457 PER LE SCALE

IN GENERALE E ALLA A-545 PER DETTAGLIO DELLE SCALE.

1:25

0 1.00.5

SCALE:

1.5 2.5

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:5 :3

P M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

A e n ve lo p e .r vt

KLB RBTCMG

4B R

T O

W N

H O

U S

E S

TA

IR

P

LA

N S

A N

D S

E C

TI

O

N 4B

R T

O W

N H

O U

S E

P

IA

N

TE

E S

E

ZI

O N

I S C

A

LA

A-446

14106334

1656273

C M G

SCALEA-432

C2

1 : 25 B3

4 BR TH GROUND STAIR PLAN /

TOWNHOUSE 4BR PIANTA

SCALA PIANO TERRA

SCALEA-432

C2

1 : 25 B4

4 BR TH FIRST STAIR PLAN /

TOWNHOUSE 4BR PIANTA

SCALA PIANO PRIMO

SCALEA-432

C2

1 : 25 A3

4 BR TH SECOND STAIR PLAN /

TOWNHOUSE 4BR PIANTA SCALA PIANO SECONDO

SCALEA-446

D3

1 : 25 A1

4BR TH STAIR SECTION /

TOWNHOUSE 4BR SEZIONE SCALA

T

BB CC

A1 A-447

460 900 1135

10151200

E

Q T

= 2

385 900 1210

1120 100

L004

DINING

L001

CIRCULATION

L002

CIRCULATION

0.000 FFL

P01

EW1EW1

P01

P04

P01P01

EW1

P04

E

Q T=

BB CC

A1 A-447

180 1000 130 1010 180

2.520 FFL

3.420 FFL

L101

CIRCULATION

C1 A-506

BB CC

A1 A-4472495

180 1000 130 1010 180

5.220 FFL

6.840 FFL

L201

CIRCULATION

EW1

P04

P01

EW1 EW1

P01 P01

D

C1 A-545

SE_GROUND TOC

-60

SE_FIRST TOC

SE_SECOND TOC

2928 32 333938 43

GARAGE EAVE

L001

CIRCULATION

L002

CIRCULATION

L101

CIRCULATION

L201

CIRCULATION

6.840 FFL

3.420 FFL

0.000 FFL

A4 A-545

C4 A-545

B1 A-545

EQ

R = 1

E

Q R=

5 E Q

R=

E Q

R=

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SHEET A-001 & I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS /

FARE RIFERIMENTO ALLA TAVOLA A-001 & I-001 PER NOTE GENERALI, LEGENDE E

SIMBOLI

2. REFER TO FINISH SCHEDULE FOR STAIR FINISH / FARE RIFERIMENTO ALL'ABACO

DELLE FINITURE PER FINITURE DELLE SCALE

3. REFER TO SHEET A-455; A-456; A-457 FOR DETAILS AND A-525 FOR STANDARD

DETAILS / FARE RIFERIMENTO ALLA SCHEDA A-455; A-456; A-457 PER I DETTAGLI E

A-525 PER I DETTAGLI STANDARD

4. REFER TO SHEETS A-445; A-446; A-447 FOR STAIRS IN GENERAL AND A-545 FOR

STAIR DETAILS / FARE RIFERIMENTO ALLE TAVOLE A-455; A-456; A-457 PER LE SCALE

IN GENERALE E ALLA A-545 PER DETTAGLIO DELLE SCALE.

1:25

0 1.00.5

SCALE:

1.5 2.5

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:5 :4

P M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

A e n ve lo p e .r vt

KLB RBTMX

5B R

T O

W N

H O

U S

E S

TA

IR

P

LA

N S

A N

D S

E C

TI

O

N 5B

R T

O W

N H

O U

S E

P

IA

N

TE

E S

E

ZI

O N

I S C

A

LA

A-447

14106335

1656273

M X

SCALEA-433

C2

1 : 25 B3

5 BR TH GROUND STAIR PLAN /

TOWNHOUSE 5BR PIANTA

SCALA PIANO TERRA

SCALEA-433

C2

1 : 25 B4

5 BR TH FIRST STAIR PLAN /

TOWNHOUSE 5BR PIANTA

SCALA PIANO PRIMO

SCALEA-434

C2

1 : 25 A3

5 BR TH SECOND STAIR PLAN /

TOWNHOUSE 5BR PIANTA SCALA PIANO SECONDOSCALEA-447

D3

1 : 25 A1

5BR TH STAIR SECTION /

TOWNHOUSE 5BR SEZIONE SCALA

UP

DN

UP

UP

UP

UP

A3 A-546

2T @ 280 = 560

-0.360

-0.180

0.000

EQ

EQ

A1 A-394

A3 A-29110.03

7.15

7.17

A3

A-541 OH

2T @ 280 = 560

-0.375

-0.215

-0.050

COL

10.03

7.152%

A3 A-541

OH

2T

0 =

560 2200

-0.195

-0.370

-0.025

COL

7.17

2%

A1 A-546

2T

0 5

-0.265

-0.405

-0.130

1800300

A1 A-294

7.17

C3 A-546

-0.065

-0.225

-0.380

2452005245

COL COL

A3 A-294

10.03

C1 A-546

2T

0 =

-0.370

-0.200

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SHEET A-001 & I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS /

FARE RIFERIMENTO ALLA TAVOLA A-001 & I-001 PER NOTE GENERALI, LEGENDE E

SIMBOLI

2. REFER TO FINISH SCHEDULE FOR STAIR FINISH / FARE RIFERIMENTO ALL'ABACO

DELLE FINITURE PER FINITURE DELLE SCALE

3. REFER TO SHEET A-455; A-456; A-457 FOR DETAILS AND A-525 FOR STANDARD

DETAILS / FARE RIFERIMENTO ALLA SCHEDA A-455; A-456; A-457 PER I DETTAGLI E

A-525 PER I DETTAGLI STANDARD

4. REFER TO SHEETS A-445; A-446; A-447 FOR STAIRS IN GENERAL AND A-545 FOR

STAIR DETAILS / FARE RIFERIMENTO ALLE TAVOLE A-455; A-456; A-457 PER LE SCALE

IN GENERALE E ALLA A-545 PER DETTAGLIO DELLE SCALE.

1:25

0 1.00.5

SCALE:

1.5 2.5

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:5 :5

P M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

TH

A e n ve lo p e .r vt

KLB RBTMX

E X

TE

R

IO

R

S

TA

IR

P

LA

N

S P

IA

N

TE

S

C A

LA

E

S

TE

R N

A

A-448

14106336

1656273

M X

SCALEA-431

C2

1 : 25 C1

3 BR TH REAR STAIR /

TOWNHOUSE 3BR SCALA RETROSTANTE

SCALEA-431

C2

1 : 25 B1

3 BR TH FRONT STAIR /

TOWNHOUSE 3BR SCALA FRONTALE

SCALEA-432

C2

1 : 25 C2

4 BR TH FRONT STAIR /

TOWNHOUSE 4BR SCALA FRONTALE

SCALEA-432

C2

1 : 25 B2

4 BR TH REAR STAIR /

TOWNHOUSE 4BR SCALA RETROSTANTE

SCALEA-433

C2

1 : 25 C3

5 BR TH REAR STAIR /

TOWNHOUSE 5BR SCALA RETROSTANTE

SCALEA-433

C2

1 : 25 B3

5 BR TH FRONT STAIR /

TOWNHOUSE 5BR SCALA FRONTALE

NOTE CHIAVE DI FOGLIO:

SHEET KEYNOTES: /

7.15 TERRACOTTA SUNSCREEN SYSTEM. REFER TO SCHEDULE ON SHEET A-609.

REFER TO DETAIL ON SH A-504, UNO / SISTEMA BRISE SOLEIL IN

TERRACOTTA. VEDI L'ABACO SU TAV A-609, VEDI DETTAGLIO SU TAV A-504,

UNO

7.17 PREFINISHED ALUMINUM ROUND 100MM DIAMETER DOWNSPOUT WITH

PREFABRICATED ELBOWS AND OFFSETS. REFER TO DETAIL C1 ON SHEET

A-507 / PLUVIALE IN ALLUMINIO PREFINITO TONDO DIAMETRO 100MM CON

GOMITI E RACCORDI PREFABBRICATI . VEDI DETTAGLIO C1 SU TAV A-507

10.03 EXTERIOR SIGNAGE. TYPE B DWELLING UNIT NUMBER SIGN. REFER TO

SIGNAGE SCHEDULE ON SHEET IS602 / SEGNALETICA ESTERNA. EDIFICIO

TIPO B SENZA SEGNALETICA. VEDI SEGNALETICA NELL'ABACO SULLA TAV

IS602

DN

6 7 8

G

H

A1 A-451

450 3450

P17

1700 RO 1225

125 27

200 125

3200 125

AR_GROUND FFL

EL 0

AR_FIRST FFL

EL 3400

AR_THIRD FFL

EL 10200

PENTHOUSE

EL 13600

G H

0 T

OT

AL

T

RA

VE

L / P

ER

CO

RS

O

TO

TA

LESECOND FFL

EL 6800

C2 A-451

R O, TY

P

MACH

P02

S

PA

ZIO

S

UP

ER

IO

RE

LI

BE

RO

C

LE

AR

O

VE

RH

EA

D

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

A

LT

EZ

ZA

A

UT

O

C

AR

H T

C

LR

D R, T

YP

PIT DEPTH /

PROFONDITA' POZZETTO

3.08 3.08

A2 A-544

OH

B2 A-544

OH 7 8

G

H

A1 A-451

5.04

7.06

5.05

A3 A-544

C3 A-544

6 7 8 12

G

H

A1 A-451

P02

MACHINE

P02

P01

VESTIBULE

C2 A-451

5.319

EW2A

EW2A

EW2A

3450 1500 (5 EQ T) 90090

5.11

P01

450 3450

4415 125

5.19

325 125

200 LV-E

14550 5.12

P01A

PENTHOUSE

EL 13600

7 8

P02

MACHINE

6R

8 =

P01

VESTIBULE14550

6 E Q

R

6 7 8 9 12

G

H

F

A1 A-451

E

275 1700 1225

MECHANICAL

MECHANICAL

CORRIDOR

P17

P16

P16

EW1A

P16

2120 3655 2290

P04

P04 P04

125 125200

125 3200 125

175 1575 125 125 2165 125

P17 P04

P04

C2 A-544

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

0 421 3 5

SCALE: 1:50

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:2 :3

A M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

A e n ve lo p e .r vt

KLB RBTCMG

A P

B U

IL

D

IN

G

E

LE

V

A

TO

R P

LA

N

S A

N D

S E

C

TI

O N

S A

P E

D

IF

IC

IO

P

R O

S P

E

TT

I E S

E

ZI

O N

I

A-451

14106337

1656273

C M G

SCALEA-101 1 : 50

B2 B2

ELEV - GROUND FLOOR PLAN /

ASCENSORE - PIANTA PIANO TERRA

SCALEA-451 1 : 50

B2 A1

ELEV - SECT /

SEZIONE DELL'ASCENSORE

SCALEA-201 1 : 50

A2

ELEV - PIT PLAN /

PIANTA FOSSA DELL'ASCENSORE

SCALEA-105 1 : 50

B3 A3

ELEV MACH RM PLAN /

PIANTA DELLA SALA MACCHINE DELL'ASCENSORE

SCALEA-451 1 : 50

A3 C2

ELEV MACH RM SECT /

SEZIONE DELLA SALA MACCHINE DELL'ASCENSORE

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SHEET A-001& I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. /

FARE RIFERIMENTO ALLA TAVOLA A-001& I-001 PER LE NOTE GENERALI, LEGENDE E

SIMBOLI .

2. COORDINATE HOISTWAY DIMENSIONS, HOISTWAY OPENING SIZES, PIT DEPTH AND

OVERRUN WITH ACTUAL MANUFACTURER'S REQUIREMENTS. / COORDINARE LE

DIMENSIONI DEL VANO ASCENSORE, DIMENSIONI APERTURA VANO ASCENSORE,

PROFONDITÀ POZZETTO E EXTRACORSA CON REQUISITI RACCOMANDATI DAL

PRODUTTORE.

3. CAST IN PLACE CONCRETE WALLS THAT ENCLOSE HOISTWAY ARE 2-HOUR FIRE

RATED. FIRESTOP PENETRATIONS AND JOINTS. / I MURI IN C.A. GETTATO IN OPERA

CHE INCLUDONO IL VANO ASCENSORE HANNO RESISTENZA AL FUOCO PER 120

MINUTI. SIGILLATURA TAGLIAFUOCO PENETRAZIONI E GIUNTI.

4. CAST IN PLACE CONCRETE WALLS THAT ENCLOSE MACHINE ROOM ARE 2-HOUR

FIRE RATED. FIRESTOP PENETRATIONS AND JOINTS. / I MURI IN C.A. GETTATO IN

OPERA CHE INCLUDONO LA SALA MACCHINE HANNO RESISTENZA AL FUOCO PER

120 MINUTI. SIGILLATURA TAGLIAFUOCO PENETRAZIONI E GIUNTI.

5. PROVIDE AN ELEVATOR WITH A RATED LOAD OF 3500 LBS (1588 KG) AND A

MINIMUM SIZE AND ARRANGEMENT TO ACCOMODATE AN AMBULANCE STRETCHER

610MM BY 2134MM WITH NOT LESS THAN 127MM RADIUS CORNERS, IN THE OPEN,

HORIZONTAL POSITION. / FORNIRE IN OPERA UN ASCENSORE CON UNA PORTATA DI

3500 LIBBRE (1588 KG) CON UNA DIMENSIONE MINIMA E UNA CONFIGURAZIONE PER

ACCOGLIERE UNA BARELLA AMBULANZA 610MM PER 2134MM CON ANGOLI NON

MENO DI 127MM DI DIAMETRO, IN POSIZIONE APERTA ORIZZONTALE

NOTE CHIAVE DI FOGLIO:

SHEET KEYNOTES /

3.08 CONCRETE DECK / IMPALCATO IN CALCESTRUZZO

5.04 ELEVATOR SUMP PIT. REFER TO C3 ON SHEET A-544 / SEZIONE POZZETTO

SIFONATO. VEDI C3 SU TAV A-544

5.05 ELEVATOR PIT LADDER. REFER TO A3 ON SHEET A-544/ SEZIONE SCALA PER

POZZETTO. VEDI A3 SU TAV A-544

5.11 PAINTED STEEL WALL MOUNTED HANDRAIL. REFER TO D2 ON SH A-543 /

CORRIMANO IN ACCIAIO VERNICIATO MONTATO A PARETE. VEDI D2 SU TAV

A-543

5.12 PAINTED STEEL RAILING WITH HANDRAIL. REFER TO A1 ON SHEET A-543 /

RINGHIERA IN ACCIAIO VERNICIATO CON CORRIMANO. VEDI A1 SU TAV A-543

5.19 LADDER RAILS, TYPICAL / RINGHIERE PER SCALE, TIPOLOGICO

5.319 PAINTED STEEL GUARDRAIL AT APARTMENT LANDING. REFER TO B1 ON

SHEET A-543 / RINGHIERA IN ACCIAIO VERNICIATO AL PIANO DI ARRIVO

DELL'APPARTAMENTO. FARE RIFERIMENTO A B1 SULLA SCHEDA A-543.

7.06 METALLIC OXIDE WATERPROOFING / IMPERMEABILLIZZANTE AGLI OSSIDI

METALLICI

SCALEA-102 1 : 50

C2 C3

ENLARGED FLOOR PLAN - TYP /

PIANTA INGRANDITA DEL PIANO TERRA - TIPICA

C

D

8 10

E

A1 A-452

P05 P17

125 2500 125

C2 A-544

AR_GROUND FFL

AR_SECOND FFL

AR_FIRST FFL

AR_THIRD FFL

10200

SE_GROUND TOC

-60

SE_FIRST TOC

SE_SECOND TOC

SE_THIRD TOC

10140

8 10

4150 CLEAR

OVERHEAD / 4150

SPAZIO

SUPERIORE

LIBERO

A

LT

EZ

ZA

A

UT

O

C

AR

H T

C

LR

D R, T

YP

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

MECHANICAL ROOM

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

PIT DEPTH /

PROFONDITA' POZZETTO

B2 A-544

A2 A-544

OH

OH

C

D

7 8 10

E

A1 A-452

1820 2750

MECHANICAL ROOM

CORRIDOR

P05

P17

P04

G201

EW2A

P01

B002

DINING

B001

FOYER

ELEVATOR

B

C

D

7 8 10 11 12

E

C1 A-452

P0

1500 (5 EQ T)

14550 13600

1820 2750 2300 2910

5.319

5.12

5.12

P02

MECHANICAL ROOMC1

A-502

AR_PENTHOUSE FFL

13600

TOW

17700

SE_PENTHOUSE TOC

13540

7 8 10 11 12

TOP OF ROOF SLAB

13910

6 R

8 =

C

LE

AR

OV

ER

HE

AD

SP

AZ

IO

SU

PE

RI

OR

E

LIB

ER

O

1820 2750 2300 2910

P02

MECHANICAL ROOM

14550

C

D

8 10

E

A1 A-452 A3

A-544 C3

A-544 5.04 5.05

7.06

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

0 421 3 5

SCALE: 1:50

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:5 :1

A M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

A e n ve lo p e .r vt

KLB RBTCMG

A P

B U

IL

D

IN

G

E

LE

V

A

TO

R P

LA

N

S A

N D

S E

C

TI

O N

S A

P E

D

IF

IC

IO

P

IA

N

TA

E

S E

ZI

O

N I A

S C

E N

S O

R E

A-452

14106338

1656273

C M G

SCALEA-111

C2

1 : 50 B3

ELEVATOR GROUND FLOOR PLAN /

ASCENSORE - PIANTA PIANO TERRA

SCALEA-452 1 : 50

B2 A1

ELEVATOR SECTION /

SEZIONE DELL'ASCENSORE

SCALEA-113

C2

1 : 50 C3

ENLARGED FLOOR PLAN - TYPICAL /

PIANTA INGRANDITA DEL PIANO TERRA - TIPICA

SCALEA-114

C2

1 : 50 A3

ELEVATOR MACHINE ROOM PLAN /

PIANTA DELLA SALA MACCHINE DELL'ASCENSORE

SCALEA-214 1 : 50

A3 C1

ELEVATOR MACHINE ROOM SECTION /

SEIZIONE DELLA SALA MACCHINE DELL'ASCENSORE

SCALE

C2

1 : 50 B2

ELEVATOR PIT PLAN /

PIANTA FOSSA DELL'ASCENSORE

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SHEET A-001& I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. /

FARE RIFERIMENTO ALLA TAVOLA A-001& I-001 PER LE NOTE GENERALI, LEGENDE E

SIMBOLI .

2. COORDINATE HOISTWAY DIMENSIONS, HOISTWAY OPENING SIZES, PIT DEPTH AND

OVERRUN WITH ACTUAL MANUFACTURER'S REQUIREMENTS. / COORDINARE LE

DIMENSIONI DEL VANO ASCENSORE, DIMENSIONI APERTURA VANO ASCENSORE,

PROFONDITÀ POZZETTO E EXTRACORSA CON REQUISITI RACCOMANDATI DAL

PRODUTTORE.

3. CAST IN PLACE CONCRETE WALLS THAT ENCLOSE HOISTWAY ARE 2-HOUR FIRE

RATED. FIRESTOP PENETRATIONS AND JOINTS. / I MURI IN C.A. GETTATO IN OPERA

CHE INCLUDONO IL VANO ASCENSORE HANNO RESISTENZA AL FUOCO PER 120

MINUTI. SIGILLATURA TAGLIAFUOCO PENETRAZIONI E GIUNTI.

4. CAST IN PLACE CONCRETE WALLS THAT ENCLOSE MACHINE ROOM ARE 2-HOUR

FIRE RATED. FIRESTOP PENETRATIONS AND JOINTS. / I MURI IN C.A. GETTATO IN

OPERA CHE INCLUDONO LA SALA MACCHINE HANNO RESISTENZA AL FUOCO PER

120 MINUTI. SIGILLATURA TAGLIAFUOCO PENETRAZIONI E GIUNTI.

5. PROVIDE AN ELEVATOR WITH A RATED LOAD OF 3500 LBS (1588 KG) AND A

MINIMUM SIZE AND ARRANGEMENT TO ACCOMODATE AN AMBULANCE STRETCHER

610MM BY 2134MM WITH NOT LESS THAN 127MM RADIUS CORNERS, IN THE OPEN,

HORIZONTAL POSITION. / FORNIRE IN OPERA UN ASCENSORE CON UNA PORTATA DI

3500 LIBBRE (1588 KG) CON UNA DIMENSIONE MINIMA E UNA CONFIGURAZIONE PER

ACCOGLIERE UNA BARELLA AMBULANZA 610MM PER 2134MM CON ANGOLI NON

MENO DI 127MM DI DIAMETRO, IN POSIZIONE APERTA ORIZZONTALE

NOTE CHIAVE DI FOGLIO:

SHEET KEYNOTES /

5.04 ELEVATOR SUMP PIT. REFER TO C3 ON SHEET A-544 / SEZIONE POZZETTO

SIFONATO. VEDI C3 SU TAV A-544

5.05 ELEVATOR PIT LADDER. REFER TO A3 ON SHEET A-544/ SEZIONE SCALA PER

POZZETTO. VEDI A3 SU TAV A-544

5.12 PAINTED STEEL RAILING WITH HANDRAIL. REFER TO A1 ON SHEET A-543 /

RINGHIERA IN ACCIAIO VERNICIATO CON CORRIMANO. VEDI A1 SU TAV A-543

5.319 PAINTED STEEL GUARDRAIL AT APARTMENT LANDING. REFER TO B1 ON SHEET

A-543 / RINGHIERA IN ACCIAIO VERNICIATO AL PIANO DI ARRIVO

DELL'APPARTAMENTO. FARE RIFERIMENTO A B1 SULLA SCHEDA A-543.

7.06 METALLIC OXIDE WATERPROOFING / IMPERMEABILLIZZANTE AGLI OSSIDI

METALLICI

SECOND FLOOR SHOWN /

MOSTRATO IL PIANO SECONDO

F

E

A1 A-453

P05

P05

P17

AR_GROUND FFL

AR_SECOND FFL

AR_FIRST FFL

AR_THIRD FFL

10200

AR_PENTHOUSE FFL

13600

TOW

17700

E

TOP OF ROOF SLAB

13910

C2 A-453

0 95

S

PA

ZIO

S

UP

ER

IO

RE

LI

BE

RO

C

LE

AR

O

VE

RH

EA

D

A

LT

EZ

ZA

A

UT

O

C

AR

H T

C

LR

D R, T

YP

PIT DEPTH /

PROFONDITA' POZZETTO

0 T

OT

AL

T

RA

VE

L / P

ER

CO

RS

O

TO

TA

LE

B2 A-544

A2 A-544

F

F

E

A1 A-453

C2 A-453

13.600

14.550

(5 E

Q T)

5.12

5.11

P02

MECHANICAL ROOM

P02A P02B

P05

P05

8.16

8.16

8.16

8.16

AR_PENTHOUSE FFL

13600

TOW

17700

1197 8 10

TOP OF ROOF SLAB

13910

6R

8 =

5320 2190 3460 450

P02

MECHANICAL ROOM

F

E

A1 A-453

A3 A-544

C3 A-544

5.05

5.04

7.06

F

D

E

A1 A-453

MECHANICAL ROOM

MECHANICAL ROOM

CORRIDOR

8.16

580 665 615

P16

P17

P04

P16

A101

J

C101

P16

D101

C2 A-544

EW2A

P05

P17

P05

P16

P04

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

PLAN

NORTH

0 421 3 5

SCALE: 1:50

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

NORTH

NORD

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:1 :2

P M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

A e n ve lo p e .r vt

KLB RBTCMG

A P

B U

IL

D

IN

G

E

LE

V

A

TO

R P

LA

N

S A

N D

S E

C

TI

O N

S A

P E

D

IF

IC

IO

P

IA

N

TA

E

S E

ZI

O

N I A

S C

E N

S O

R E

A-453

14106339

1656273

C M G

SCALEA-121

C2

1 : 50 B2

ELEVATOR GROUND FLOOR PLAN /

ASCENSORE - PIANTA PIANO TERRA

SCALEA-453

A2

1 : 50 A1

ELEVATOR SECTION /

SEZIONE DELL'ASCENSORE

SCALEA-124

B1

1 : 50 B4

ELEVATOR MECHANICAL ROOM PLAN /

PIANTA DELLA SALA MACCHINE

DELL'ASCENSORE

SCALEA-453

D4

1 : 50 C2

ELEVATOR MECHANICAL ROOM SECTION /

SEZIONE DELLA SALA MACCHINE DELL'ASCENSORE

SCALEA-121

C2

1 : 50 A2

ELEVATOR PIT PLAN /

PIANTA FOSSA DELL'ASCENSORE

SCALEA-122

B2

1 : 50 A3

ENLARGED FLOOR PLAN - TYPICAL /

PIANTA PIANO TIPO INGRANDITA

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SHEET A-001& I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. /

FARE RIFERIMENTO ALLA TAVOLA A-001& I-001 PER LE NOTE GENERALI, LEGENDE E

SIMBOLI .

2. COORDINATE HOISTWAY DIMENSIONS, HOISTWAY OPENING SIZES, PIT DEPTH AND

OVERRUN WITH ACTUAL MANUFACTURER'S REQUIREMENTS. / COORDINARE LE

DIMENSIONI DEL VANO ASCENSORE, DIMENSIONI APERTURA VANO ASCENSORE,

PROFONDITÀ POZZETTO E EXTRACORSA CON REQUISITI RACCOMANDATI DAL

PRODUTTORE.

3. CAST IN PLACE CONCRETE WALLS THAT ENCLOSE HOISTWAY ARE 2-HOUR FIRE

RATED. FIRESTOP PENETRATIONS AND JOINTS. / I MURI IN C.A. GETTATO IN OPERA

CHE INCLUDONO IL VANO ASCENSORE HANNO RESISTENZA AL FUOCO PER 120

MINUTI. SIGILLATURA TAGLIAFUOCO PENETRAZIONI E GIUNTI.

4. CAST IN PLACE CONCRETE WALLS THAT ENCLOSE MACHINE ROOM ARE 2-HOUR

FIRE RATED. FIRESTOP PENETRATIONS AND JOINTS. / I MURI IN C.A. GETTATO IN

OPERA CHE INCLUDONO LA SALA MACCHINE HANNO RESISTENZA AL FUOCO PER

120 MINUTI. SIGILLATURA TAGLIAFUOCO PENETRAZIONI E GIUNTI.

5. PROVIDE AN ELEVATOR WITH A RATED LOAD OF 3500 LBS (1588 KG) AND A

MINIMUM SIZE AND ARRANGEMENT TO ACCOMODATE AN AMBULANCE STRETCHER

610MM BY 2134MM WITH NOT LESS THAN 127MM RADIUS CORNERS, IN THE OPEN,

HORIZONTAL POSITION. / FORNIRE IN OPERA UN ASCENSORE CON UNA PORTATA DI

3500 LIBBRE (1588 KG) CON UNA DIMENSIONE MINIMA E UNA CONFIGURAZIONE PER

ACCOGLIERE UNA BARELLA AMBULANZA 610MM PER 2134MM CON ANGOLI NON

MENO DI 127MM DI DIAMETRO, IN POSIZIONE APERTA ORIZZONTALE

NOTE CHIAVE DI FOGLIO:

SHEET KEYNOTES: /

5.04 ELEVATOR SUMP PIT. REFER TO C3 ON SHEET A-544 / SEZIONE POZZETTO

SIFONATO. VEDI C3 SU TAV A-544

5.05 ELEVATOR PIT LADDER. REFER TO A3 ON SHEET A-544/ SEZIONE SCALA PER

POZZETTO. VEDI A3 SU TAV A-544

5.11 PAINTED STEEL WALL MOUNTED HANDRAIL. REFER TO D2 ON SH A-543 /

CORRIMANO IN ACCIAIO VERNICIATO MONTATO A PARETE. VEDI D2 SU TAV

A-543

5.12 PAINTED STEEL RAILING WITH HANDRAIL. REFER TO A1 ON SHEET A-543 /

RINGHIERA IN ACCIAIO VERNICIATO CON CORRIMANO. VEDI A1 SU TAV A-543

7.06 METALLIC OXIDE WATERPROOFING / IMPERMEABILLIZZANTE AGLI OSSIDI

METALLICI

8.16 600mm X 600mm ACCESS PANEL / PORTA DI ACCESSO 600mm X 600mm

L

J

K

EW9A

EW7A

EW1AEW1A

EW9A

SL

P

DN

2%

A015

BALCONY

E

125 3900 125

1050 2050 1050

5.08

5.08

C1 A-506

C1 A-506

A3 A-531

A3 A-531

B1 A-501

9.16

LL

J

K

320 3900 320

EW11A

5.08

[No Slope]

E

A015

BALCONY

EW1A EW1A

C1 A-506

C1 A-506

B1 A-524

SIM

3.314

7.126

C3 A-524

C3 A-524

7.358

SLOPE DOWN

5% BELOW

DISCESA

5% SOTTO

SL

OP

E

DO

W N

5%

AT

C

ON

CR

ET

E

DE

CK

B

EL

OW

SU

L P

IA

NO

IN

CA

LC

ES

TR

UZ

ZO

SO

TT

O

SIM

SIM

D

F

2160 125 790

EW11A

EW1A

EW1A

5.08

125 2950

C1 A-506

B015

BALCONY

B004

LIVING

B003

KITCHEN

SLP DN 2%

A2 A-503

C3 A-531

C3 A-531 9.16

D

790 125 2160

2950 125

F

EW8A

EW1A

EW11A

5.08

B115

BALCONY

C2 A-506

A1 A-524

A2 A-524

7.18

SL

OP

E

DO

W N

5% B

EL

OW

DI

SC

ES

A

5% S

OT

TO

SLOPE DOWN 5%

AT CONCRETE

DECK BELOW /

SUL PIANO IN

CALCESTRUZZO

SOTTO

SL

OP

E

DO

W N

5% B

EL

OW

DI

SC

ES

A

5% S

OT

TO

[No Slope]7.358

SIM

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE

RIFERIMENTO ALLA TAVOLA I-001 PER LE NOTE GENERALE, LEGENDE E SIMBOLI.

2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL

BUILDINGS IN PHASE 3. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION

OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / LE PIANTE DELLE UNITÀ SONO

RAPPRESENTATIVE DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 3. FARE

RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA

RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ

3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601

AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA

DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE

TABELLE DELLE FINITURE.

4. THESE PLANS SHOULD BE READ IN CONJUNCTION WITH INDIVIDUAL APARTMENT

BUILDING PLANS TO IDENTIFY EXACT LOCATIONS. / QUESTE PIANTE DEVONO

ESSERE LETTE INSIEME ALLE PIANTE DEI SINGOLI APPARTAMENTI PER INDIVIDUARE

LE POSIZIONI ESATTE.

L

K

125 4490

E EW1A

EW11A

EW11A

SL

P

DN

2%

F016

BALCONY

F003

LIVING

F004

KITCHEN

5.08

A2 A-503

C1 A-506

C3 A-531

C1 A-506

SIM

AT ACCESSIBLE DWELLING /

AD ABITAZIONE ACCESSIBILE

SIM,

UNO

9.16

C3 A-531

A1 A-525

3 6

C

125 4065

EW1A

EW1A

EW1A

G019

BALCONY

G003

LIVING

F

5.08

7.19

7.12 C2

A-506

B1 A-524

B3 A-524

SLOPE DOWN 5%

AT CONCRETE

DECK BELOW /

SUL PIANO IN

CALCESTRUZZO

SOTTO

SL

OP

E

DO

W N

5% B

EL

OW

DI

SC

ES

A

5% S

OT

TO

SL

OP

E

DO

W N

5% B

EL

OW

DI

SC

ES

A

5% S

OT

TO

[No Slope]

7.358

7.18

C2 A-506

C1 A-508

SIM

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

0 421 3 5

SCALE: 1:50

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:2 :4

A M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

A e n ve lo p e .r vt

KLB RBTCMG

A P

B U

IL

D

IN

G

E

N

LA

R G

E D

B A

LC

O

N Y

P

LA

N S

A P

E D

IF

IC

IO

P

IA

N

TA

B A

LC

O

N E

IN

G

R A

N D

IT

A

A-461

14106340

1656273

C M G

SCALEA-101 1 : 50

B2 A1

3BR GROUND FLOOR BALCONY PLAN /

3BR PIANO TERRA PIANO BALCONE

NOTE CHIAVE DI FOGLIO:

SHEET KEYNOTES /

3.314 VALLEY AT ROOF MEMBRANE BELOW / MEMBRANA SOTTO COPERTURA

IMPLUVIO

5.08 PAINTED GALVANIZED STEEL EXTERIOR BALCONY RAILING. REFER TO A3

AND C3 ON SHEET A-531 / RINGHIERA ESTERNA PER BALCONE IN ACCIAIO

GALVANIZZATO VERNICIATO. VEDI A3 E C3 SU TAV A-531

7.12 CLAY ROOF TILE SYSTEM. ROOF PITCH 3:10. STEEP SLOPE ROOF TYPE 1.

REFER TO SHEET A-605 / SISTEMA DI COPERTURA A TEGOLE IN

TERRACOTTA. INCLINAZIONE TETTO 3:10. TETTO A FALDA TIPO 1. VEDI

TAV A-605

7.18 PREFINISHED HALF ROUND ALUMINUM GUTTERS 150MM WIDE /

GRONDAIE IN ALLUMINIO SEMICIRCOLARI PREFINITE 150MM DI

LARGHEZZA

7.19 PREFINISHED ALUMINUM COPING. REFER TO DETAIL A3, AND C3 ON

SHEET A-521 / COPERTINA IN ALLUMINIO PREFINITO. VEDI PARTICOLARE

A3, E C3 SULLA TAV A-521

7.126 CONDUCTOR HEAD, REFER TO C3 ON SHEET A-522 / TESTA DEL

CONDUTTORE, FARE RIFERIMENTO A C3 SUL FOGLIO A-522

7.358 100 X 200 WIDE PREFINISHED ALUMINUM SCUPPER. REFER TO C1/A-522

AND A3/A-523 FOR NOTES AND SIMILAR DIMENSIONS / SCOSSALINA IN

ALLUMINIO PREFINITA LARGHEZZA 100X200. FARE RIFERIMENTO A

C1/A-522 E A3/A-523 PER LE NOTE E LE DIMENSIONI TIPICHE

9.16 PORCELAIN TILE 300X600 MM SRI 53 BEIGE / GRES PORCELLANATO

300X600 MM SRI 53 BEIGE

SCALEA-104 1 : 50

B2 C2

AP 27100 3BR THIRD FLOOR BALCONY PLAN /

AP 27100 3BR TERZO PIANO PIANTA BALCONE

SCALEA-103 1 : 50

C3 C1

TYP 3BR BALCONY PLAN /

3BR TIPICA PIANTA BALCONE

SCALEA-102 1 : 50

C2 A2

AP 27100 3BR FIRST FLOOR BALCONY PLAN /

AP 27100 3BR PRIMO PIANO PIANTA BALCONE

SCALEA-102 1 : 50

A2 C3

4BR BALCONY PLAN /

4BR PIANTA BALCONE

SCALEA-104 1 : 50

C2 A3

5BR THIRD FLOOR BALCONY PLAN /

5BR TERZO PIANO PIANTA BALCONE

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SHEET I-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / FARE

RIFERIMENTO ALLA TAVOLA I-001 PER LE NOTE GENERALE, LEGENDE E SIMBOLI.

2. THE UNIT PLANS ARE REPRESENTATIVE OF THAT UNIT TYPE ACROSS ALL

BUILDINGS IN PHASE 3. REFER TO GENERAL NOTES G-002 FOR FULL EXPLANATION

OF BUILDINGS BREAKDOWN AND UNIT BREAKDOWN. / LE PIANTE DELLE UNITÀ SONO

RAPPRESENTATIVE DI QUEL TIPO DI UNITÀ IN TUTTI GLI EDIFICI DELLA FASE 3. FARE

RIFERIMENTO ALLE NOTE GENERALI G-002 PER UNA SPIEGAZIONE COMPLETA DELLA

RIPARTIZIONE DEGLI EDIFICI E DELLA RIPARTIZIONE DELLE UNITÀ

3. REFER TO I-001 FOR INTERIOR FINISHES LEGEND AND REFER TO DRAWINGS I-601

AND I-602 FOR FINISHES SCHEDULES. / FARE RIFERIMENTO A I-001 PER LA LEGENDA

DELLE FINITURE INTERNE E FARE RIFERIMENTO AI DISEGNI I-601 E I-602 PER LE

TABELLE DELLE FINITURE.

4. THESE PLANS SHOULD BE READ IN CONJUNCTION WITH INDIVIDUAL APARTMENT

BUILDING PLANS TO IDENTIFY EXACT LOCATIONS. / QUESTE PIANTE DEVONO

ESSERE LETTE INSIEME ALLE PIANTE DEI SINGOLI APPARTAMENTI PER INDIVIDUARE

LE POSIZIONI ESATTE.

A

B

B1 A-505

D015

BALCONY

A1 A-525

9.16

125 3485 125

835 2000 900

A4 A-524

A3 A-531

EW11A

EW9A

EW9A

EW8A

EW1A

EW8A

P01

5.15

5.15

SL

P

D N

KEYPLAN / PIANO STRATEGICO

NAPOLI

PADOVA

BOLOGNA

= BLDG LOCATIONS

= SIMILAR BLDGS

0 421 3 5

SCALE: 1:50

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

RF

O

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O

TT

E D

F

IL

E

P A

TH

A U

TH

O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:5 :1

A M

B

IM

B P A M E R

V ic e n z a p h a se

II

I_ A F H P

AP

A e n ve lo p e .r vt

KLB RBTCMG

A P

B U

IL

D

IN

G

E

N

LA

R G

E D

B A

LC

O

N Y

P

LA

N S

A P

E D

IF

IC

IO

P

IA

N

TA

B A

LC

O

N E

IN

G

R A

N D

IT

A

A-462

14106341

1656273

C M G

NOTE CHIAVE DI FOGLIO:

SHEET KEYNOTES /

5.15 PAINTED GALVANIZED STEEL WINDOW D EXTERIOR JULIETTE RAILING.

REFER TO A3 ON SHEET A-532 / RINGHIERA ESTERNA IN ACCIAIO ZINCATO

VERNICIATO PER FINESTRA D ALLA GIULIETTA. VEDI A3 SU TAV A-532

9.16 PORCELAIN TILE 300X600 MM SRI 53 BEIGE / GRES PORCELLANATO 300X600

MM SRI 53 BEIGE

SCALEA-111 1 : 50

D2 A1

3BR ABA GROUND FLOOR BALCONY PLAN /

3BR ABA PIANO TERRA PIANTA BALCONE

CR

CR

ACAC

FFL

FCL

6.22

9.20

9.38

50 550 550 50

A3 A-557

604A

603A

FFL

FCL

6.20

6.01 6.01

6.20

1000 300 600 900 600 600

A1 A-555

A3 A-555

600 600 900

300300

9.38

26.16

9.20

26.16

6.01

6.51

6.51

6.52

27.02 27.01

26.16

FFL

FCL

A2 A-555

9.38

6.20 22.15

6.20

6.01

22.14

600600900300600

6.01

602A

9.38

10.13

26.15

6.51 6.51

26.15

26.16

FFL

FCL

601A

6.20

6.20

9.38

6.01

600 800

600 350 600 800

6.01

A1 A-555

26.16

A3 A-562

6.52

6.51

6.01

6.01 6.20

9.38

6.20

C1 A-555

FFL

FCL

60060025060

10.13

6.51

5050050050050

FFL

FCL

6.22

9.38

9.20

A1 A-557

26.15

9.20

6.22

9.38

FFL

FCL

A1 A-557

5043543543550

26.15

FFL

FCL

9.20 9.38

9.38

6.22

1110600

A1 A-560

FFL

FCL

9.38

6.22

9.20

9.38

900 1540 600

A3 A-560

FFL

FCL

006.22

9.20

9.38

9.38

A2 A-560

605A 606A

9.38

6.22

9.20

6.01

6.22

FFL

FCL

A1 A-558

26.16

26.16

9.20

6.22

6.01

9.38 6.22

FFL

FCL

A3 A-558

26.16

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SHEET A-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / RIFERISI

ALLA TAVOLA A-001 PER NOTE GENERALI, LEGENDE E SIMBOLI

2. THIS DRAWING APPLIES TO THE CORRESPONDING APARTMENT IN ALL APARTMENT

BUILDINGS AND TO MIRROR UNITS OPPOSITE HAND. DRAWING SHEETS FOR

MIRRORED UNITS ARE NOT INCLUDED. / QUESTA TAVOLA SI APPLICA

ALL'APPARTAMENTO DI RIFERIMENTO DEGLI EDIFICI APARTMENT E ALLE UNITÀ A

SPECCHIO. LE TAVOLE DELLE UNITÀ A SPECCHIO NON SONO FORNITI.

3. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL

WORK AND COORDINATION. / RIFERIRSI ALLE TAVOLE MECCANICHE, ELETTRICHE E

IDRAULICHE PER ULTERIORI LAVORI E COORDINAMENTO.

4. FILLERS AS REQUIRED AT SIDES OF CABINETS THAT ABUT TO DRYWALL. SCRIBE TO

WALL TO CONCEAL ANY CRACKS OR UNEVEN WALL SURFACES. PROVIDE ADEQUATE

SPACING AT CABINET CORNERS TO ALLOW ALL DOORS, DRAWERS, AND APPLIANCES

TO FREELY OPEN WITHOUT HITTING ADJACENT FACES OR HARDWARE. / RIEMPITIVI,

COME RICHIESTO SUI LATI DEGLI ARMADI CHE SI APPOGGIANO AL MURO IN

CARTONGESSO. MONTARE SU MURO IN MODO DA NASCONDERE QUALSIASI FESSURA

O SUPERFICIE DI MURO IRREGOLARE. FORNIRE UNA SPAZIATURA ADEGUATA AGLI

ANGOLI DELL'ARMADIO PER PERMETTERE A TUTTE LE PORTE, AI CASSETTI E AGLI

ELETTRODOMESTICI DI APRIRSI LIBERAMENTE SENZA COLPIRE LE FACCE O LA

FERRAMENTA ADIACENTI.

5. CONTRACTOR TO CONFIRM WITH CONTRACTING OFFICER THE FINAL APPLIANCES

THAT WILL BE PURCHASED AND INSTALLED BY THE GOVERNEMENT PRIOR TO

DEVELOPMENT OF SHOP DRAWINGS. SHOP DRAWINGS MUST BE COORDINATED WITH

APPLIANCE SIZES, MANUFACTURER INSTALLATION INSTRUCTIONS AND CLEARANCE

REQUIREMENTS PRIOR TO SHOP DRAWING SUBMISSION AND CABINET PRODUCTION.

/ L'APPALTATORE DEVE CONFERMARE CON IL RESPONSABILE DELL’APPALTO GLI

APPARECCHI FINALI CHE SARANNO ACQUISTATI E INSTALLATI DAL GOVERNO PRIMA

DELLA SVILUPPO DEI DISEGNI DI FABBRICAZIONE. I DISEGNI DI FABBRICAZIONE

DEVONO ESSERE COORDINATI CON LE DIMENSIONI DELL'APPARECCHIO, LE

ISTRUZIONI PER L'INSTALLAZIONE E PER LO SPAZIO LIBERO DA LASCIARE COME

INDICATO DAL PRODUTTORE, PRIMA DELLA CONSEGNA DEI DISEGNI DI

FABBRICAZIONE E LA PRODUZIONE DEI MOBILI

6. CHILD SAFETY LOCK TO CABINETS BELOW ALL SINKS AND TOP DRAWER OF

PENINSULA / BLOCCO DI SICUREZZA PER BAMBINI AI MOBILI SOTTO TUTTI I LAVANDINI

E AL CASSETTO SUPERIORE DELLA PENISOLA

7. RECEPTACLES AND SWITCH LOCATIONS SHOWN FOR COORDINATION. REFER TO

ELECTRICAL PACKAGE FOR MORE DETAILS. PRIOR TO INSTALLING DRYWALL, ALL

RECEPTICAL AND SWITCH BOXES LOCATIONS MUST BE APPROVED BY CONTRACTING

OFFICER. / PRESE E POSIZIONI DEGLI INTERRUTTORI INDICATI PER IL

COORDINAMENTO. FARE RIFERIMENTO AL PACCHETTO ELETTRICO PER MAGGIORI

DETTAGLI. PRIMA DI INSTALLARE IL CARTONGESSO, TUTTE LE POSIZIONI DELLE

PRESE E DEGLI INTERRUTTORI DEVONO ESSERE APPROVATE DAL RESPONSABILE

DELL’APPALTO.

8. KITCHEN SINKS AND SINK BASE CABINETS TO BE CENTERED ON EXTERIOR

WINDOW UNLESS NOTED OTHERWISE. ADJUST ADJACENT CABINET WIDTHS AS

NESSESASRY TO ACCOMDATE. / LAVELLI CUCINA E MOBILI BASE LAVELLO DA

CENTRARE SULLA FINESTRA ESTERNA U.N.O. REGOLARE LARGHEZZA DEI MOBILI

ADIACENTI IN BASE ALLE NECESSITÀ

9. PROVIDE MINIMUM OF 915 MM CLEAR PATHWAY FROM FRONT OF FRIDGE TO EDGE

OF PENINSULA / FORNIRE UNO SPAZIO LIBERO DI MINIMO 915 mm DAL FRONTE DEL

FRIGORIFERO AL BORDO DELLA PENISOLA.

10. GRAB BARS SHOWN DASHED ARE N.I.C. GRAB BARS SHOWN IN BATH TUBS ARE

REQUIRED, CFCI. PROVIDE IN-WALL BLOCKING FOR ALL CFCI AND N.I.C. GRAB BAR

LOCATIONS AS INDICATED. / I MANIGLIONI MOSTRATI CON IL TRATTEGGIO SONO N.I.C.

SONO NECESSARI I MANIGLIONI NELLE VASCHE DA BAGNO, CFCI. FORNIRE IL BLOCCO

NEL MURO PER TUTTI I CFCI E N.I.C. POSIZIONI DEI MANIGLIONI COME INDICATO.

11. REFER TO SHEET A-002 FOR TYPICAL MOUNTING HEIGHTS. / RIFERISI

ALLA TAVOLA A-002 PER TIPICHE ALTEZZE DI MONTAGGIO

A-471 C1

C2

C3

C4

A-471

D2

10.99

EQL EQL

601A

602A

604A 603A

6.43

CLE

AR, SEE NOTE 9

CHIARO. VEDI N

OTA 9

607A

1445 60

6.01 6.20

6.01

9.20

FFL

FCL

00607A

9.38

9.38

9.20

26.15

0 421 3 5

SCALE: 1:50

D A

TE

GRAPHIC SCALE

SCALA GRAFICA

A

B

C

D

A/E INFO

SEAL

DES DRW CHK

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

PM/DM

BRANCH MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O R

FO

LK

VA

VI

LL

AG

GI

O

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

TL

A N

TI

C

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DRAWFORM REVISION: 25 AUGUST 2020

OF

EPROJECT NO.:

1 2 3 4 5

A

B

C

D

1 2 3 4 5

A P P R

D E S C R

IP

TI

O N

S Y M

H

AM

P

TO

N

B

LV

D

VI

C

EN

ZA

IT

AL

Y

AECOM

10 S. Jefferson Street, Suite 1600 Roanoke, VA 24011

540.857.3100 tel

540.857.3180 fax

P-

1 A

RM

Y

FA

MI

LY

H

OU

SI

NG

P

RO

JE

CT

AS NOTED

CCA/MPO

DER

R. STEPHENS, PE

DPS

P L O T T E D

F

IL

E

P A T H

A U T H O R

Approved by Michele Millers, AFH-C Program Manager, USAG Italy, via email

6 OCT 2021

:5 :2

P M

B

IM

B P A M E R

V ic e n za p h a se

III

A F H P A P A e n ve lo p e .r vt

JAK RBTCRD

3B R

A P

A R

TM

E

N T

IN

TE

R

IO

R E

LE

V

A

TI

O N

S 3B

R A

P P

A R

TA

M

E N

TO

P

R O

S P

E

TT

I I N

TE

R

N I

A-471

14106342

1656273

C R D

629SCALE 1 : 50 (A-401)

A1

A001 FOYER /

A001 INGRESSO

SCALE 1 : 50 (A-471)

C1

A004 KITCHEN 1 /

A004 CUCINA 1

SCALE 1 : 50 (A-471)

C2

A004 KITCHEN 2 /

A004 CUCINA 2

SCALE 1 : 50 (A-471)

C3

A004 KITCHEN 3 /

A004 CUCINA 3

SCALE 1 : 50 (A-471)

C4

A004 KITCHEN 4 /

A004 CUCINA 4

SCALE 1 : 50 (A-401)

B4

A006 CLOSET /

A006 ARMADIO

SCALE 1 : 50 (A-401)

B3

A007 CLOSET /

A007 ARMADIO

SCALE 1 : 50 (A-401)

A2

MASTER CLOSET 1 /

ARMADIO PADRONALE 1

SCALE 1 : 50 (A-401)

A3

MASTER CLOSET 2 /

ARMADIO MAESTRO 2

SCALE 1 : 50 (A-401)

A4

MASTER CLOSET 3 /

ARMADIO PADRONALE 3

NOTE CHIAVE DI FOGLIO:

SHEET KEYNOTES /

6.01 COUNTERTOP CTP-01 / BANCO DA LAVORO CTP-01

6.20 CW-01 / CW-01

6.22 CW-04 / CW-04

6.43 PANTRY / DISPENSA

6.51 CORNER CABINET / MOBILETTO ANGOLO

6.52 BLIND CORNER CABINET / MOBILE ANGOLARE CIECO

9.20 WALL BASE WB-01 / MURO BASE WB-01

9.38 WP-01 / WP-01

10.13 CHILD SAFE LATCHING DRAWER OR DOOR / CASSETTO O PORTA CON

SICURA PER BAMBINI

10.99 PROVIDE MINIMUM OF 50MM OF CLEAR VENTILATION SPACE BETWEEN WALL

AND BACK OF FRIDGE / FORNIRE UNO SPAZIO MINIMO LIBERO DI

VENTILAZIONE PARI A 50 MM TRA LA PARETE E IL RETRO DEL FRIGORIFERO

22.14 FAUCET. SEE PLUMBING FIXTURES / RUBINETTO. VEDI FISSAGGI IMPIANTI

IDRAULICI

22.15 SINK. SEE PLUMBING FIXTURES / LAVELLO. VEDI FISSAGGI IMPIANTI

IDRAULICI

26.15 SWITCH / INTERRUTTORE

26.16 SOCKET / PRESA

27.01 TELECOMMUNICATIONS DATA OUTLET / PRESA DATI TELECOMUNICAZIONI

27.02 TELEVISION OUTLET / PRESA TELEVISIVA

SCALE 1 : 50 (A-401)

B1

A012 LAUNDRY 1 /

A012 LAVANDERIA 1

SCALE 1 : 50 (A-401)

B2

A012 LAUNDRY 2 /

A012 LAVANDERIA 2

SCALE 1 : 50 (A-401)

D1

A004 KITCHEN /

A004 CUCINA SCALE 1 : 50 (A-471)

D2

A004 KITCHEN 5 /

A004 CUCINA 5

APPLIANCE SCHEDULE / ABACO

ELETTRODOMESTICI

ITEM CODE /

CODICE OGGETTO DESCRIPTION / DESCRIZIONE

601A GFGI REFRIGERATOR / FRIGORIFERO (762x784.4x1700 MM) 602A GFGI DISHWASHER / LAVASTOVIGLIE (570x750x910 MM) 603A GFGI RANGE AND COOK TOP / PIANO COTTURA (760x660 MM) 604A CFCI RANGE HOOD / CAPPA ASPIRANTE (900x340 MM) 605A GFGI WASHING MACHINE / LAVATRICE (762x740x1120 MM) 606A GFGI DRYER / ASCIUGATORE (762x740x1120 MM) 607A OFOI MICROWAVE / (508x355x610 MM)

FFL

FCL

9.40

22.07

22.06

10.12

10.10

10.09

10.08

10.12

9.40

22.12

10.05

FFL

FCL

26.15

22.12 10.05

9.40 10.06

6.23

6.03

22.14

22.15

FFL

FCL

A1 A-559

A2 A-559 A3

A-599

26.16

10.07

600 300 500

22.12

FFL

FCL

10.05

10.12

10.08

9.39

22.07

FFL

FCL

9.39

10.05

22.12

26.15

9.39

6.23

10.06

6.03

FFL

FCL

0010.07

26.15

9.39

10.06

6.23

22.14 22.15

6.03

FFL

FCL

A3 A-559

A1 A-559

A2 A-559

26.16

26.16 10.07

10.09

FFL

FCL

10.07

22.07

22.06

10.12 10.09

9.40 10.08

10.12

50 435 435 435 50

FFL

FCL

6.22

9.38

9.20

A1 A-557

26.15

50 565 565 565 50

FFL

FCL

9.38

6.22

9.20

A1 A-557

26.15

GENERAL NOTES THIS SHEET: /

NOTE GENERALI DI QUESTO FOGLIO

1. REFER TO SHEET A-001 FOR GENERAL NOTES, LEGENDS AND SYMBOLS. / RIFERISI

ALLA TAVOLA A-001 PER NOTE GENERALI, LEGENDE E SIMBOLI

2. THIS DRAWING APPLIES TO THE CORRESPONDING APARTMENT IN ALL APARTMENT

BUILDINGS AND TO MIRROR UNITS OPPOSITE HAND. DRAWING SHEETS FOR

MIRRORED UNITS ARE NOT INCLUDED. / QUESTA TAVOLA SI APPLICA

ALL'APPARTAMENTO DI RIFERIMENTO DEGLI EDIFICI APARTMENT E ALLE UNITÀ A

SPECCHIO. LE TAVOLE DELLE UNITÀ A SPECCHIO NON SONO FORNITI.

3. REFER TO MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL

WORK AND COORDINATION. / RIFERIRSI ALLE TAVOLE MECCANICHE, ELETTRICHE E

IDRAULICHE PER ULTERIORI LAVORI E COORDINAMENTO.

4. FILLERS AS REQUIRED AT SIDES OF CABINETS THAT ABUT TO DRYWALL. SCRIBE TO

WALL TO CONCEAL ANY CRACKS OR UNEVEN WALL SURFACES. PROVIDE ADEQUATE

SPACING AT CABINET CORNERS TO ALLOW ALL DOORS, DRAWERS, AND APPLIANCES

TO FREELY OPEN WITHOUT HITTING ADJACENT FACES OR HARDWARE. / RIEMPITIVI,

COME RICHIESTO SUI LATI DEGLI ARMADI CHE SI APPOGGIANO AL MURO IN

CARTONGESSO. MONTARE SU MURO IN MODO DA NASCONDERE QUALSIASI FESSURA

O SUPERFICIE DI MURO IRREGOLARE. FORNIRE UNA SPAZIATURA ADEGUATA AGLI

ANGOLI DELL'ARMADIO PER PERMETTERE A TUTTE LE PORTE, AI CASSETTI E AGLI

ELETTRODOMESTICI DI APRIRSI LIBERAMENTE SENZA COLPIRE LE FACCE O LA

FERRAMENTA ADIACENTI.

5. CONTRACTOR TO CONFIRM WITH CONTRACTING OFFICER THE FINAL APPLIANCES

THAT WILL BE PURCHASED AND INSTALLED BY THE GOVERNEMENT PRIOR TO

DEVELOPMENT OF SHOP DRAWINGS. SHOP DRAWINGS MUST BE COORDINATED WITH

APPLIANCE SIZES, MANUFACTURER INSTALLATION INSTRUCTIONS AND CLEARANCE

REQUIREMENTS PRIOR TO SHOP DRAWING SUBMISSION AND CABINET PRODUCTION.

/ L'APPALTATORE DEVE CONFERMARE CON IL RESPONSABILE DELL’APPALTO GLI

APPARECCHI FINALI CHE SARANNO ACQUISTATI E INSTALLATI DAL GOVERNO PRIMA

DELLA SVILUPPO DEI DISEGNI DI FABBRICAZIONE. I DISEGNI DI FABBRICAZIONE

DEVONO ESSERE COORDINATI CON LE DIMENSIONI DELL'APPARECCHIO, LE

ISTRUZIONI PER L'INSTALLAZIONE E PER LO SPAZIO LIBERO DA LASCIARE COME

INDICATO DAL PRODUTTORE, PRIMA DELLA CONSEGNA DEI DISEGNI DI

FABBRICAZIONE E LA PRODUZIONE DEI MOBILI

6. CHILD SAFETY LOCK TO CABINETS BELOW ALL SINKS AND TOP DRAWER OF

PENINSULA / BLOCCO DI SICUREZZA PER BAMBINI AI MOBILI SOTTO TUTTI I LAVANDINI

E AL CASSETTO SUPERIORE DELLA PENISOLA

7. RECEPTACLES AND SWITCH LOCATIONS SHOWN FOR COORDINATION. REFER TO

ELECTRICAL PACKAGE FOR MORE DETAILS. PRIOR TO INSTALLING DRYWALL, ALL

RECEPTICAL AND SWITCH BOXES LOCATIONS MUST BE APPROVED BY CONTRACTING

OFFICER. / PRESE E POSIZIONI DEGLI INTERRUTTORI INDICATI PER IL

COORDINAMENTO. FARE RIFERIMENTO AL PACCHETTO ELETTRICO PER MAGGIORI

DETTAGLI. PRIMA DI INSTALLARE IL CARTONGESSO, TUTTE LE POSIZIONI DELLE

PRESE E DEGLI INTERRUTTORI DEVONO ESSERE APPROVATE DAL RESPONSABILE

DELL’APPALTO.

8. KITCHEN SINKS AND SINK BASE CABINETS TO BE CENTERED ON EXTERIOR

WINDOW UNLESS NOTED OTHERWISE. ADJUST ADJACENT CABINET WIDTHS AS

NESSESASRY TO ACCOMDATE.

This is the start of the file's text. The full file is on GovTribe.