Attachment C 3 DFAC 3810 Bulding Plans.pdf
PDF 701 KB Posted
- Attached to
- Ft Lee, VA Full Food Service(FFS)
- Solicitation number
- W9124J-20-R-0019
About this file
This solicitation seeks proposals for full food services at Fort Lee, Virginia. The contractor will provide all resources except Government Furnished Property to operate dining facilities, serve meals, and conduct related food service activities. The requirement is set aside for small businesses with average annual revenue under $41.5 million in NAICS code 722310. Questions are due by December 29, 2020 and proposals must be submitted by January 19, 2021 to the Mission and Installation Contracting Command at Fort Sam Houston on behalf of the Fort Lee Logistics Readiness Center and U.S. Army. The solicitation and any amendments will be posted to beta.sam.gov. Offerors must register in the System for Award Management to receive solicitation documents.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
D
35 30
35 30
1 HOUR RATED FIRE BARRIER
TYPE ABC FIRE EXTINGUISHER CABINET
TYPE K FIRE EXTINGUISHER CABINET
TYPE ABC FIRE EXTINGUISHER BRACKET MOUNTED
EXIT EGRESS CAPACITY
PATH OF TRAVEL
FIRE DEPARTMENT KEY BOX
OCCUPANT LOAD
OCCUPANT LOAD FACTOR (NFPA 101-TABLE 7.3.1.2)
FEC
K
FE
LIFE SAFETY LEGEND
FEC-K
SMOKE PARTITION
1 2 3 4
5 6 7 8 9 10 11 12
A
B
C
D
E
G
H
J
K
F
DINING
AREA A
DINING
AREA B
DISHWASHING
SALAD BAR
SERVICE
AREA #2
SERVICE
AREA #3
SERVICE
AREA #1
HEAD
COUNT
HEAD
COUNT
102 VESTIBULE
100CORRIDORS
VESTIBULE
MEN
WOMEN
DETERGENT
STORAGE
MEN
WOMEN
SYRUP &
CO2
ELECTRICAL
ROOM
FIELD
FEEDING
MECHANICAL
ROOM
STORAGE
COMM.
ROOM
BREAD
STORAGE
130KITCHEN
148OFFICE
142 OFFICE
JAN.
CLOSET
172PAPER
STORAGE
WOMEN'S
LOCKER
ROOM
141A
MEN'S
LOCKER
ROOM
MEN
WOMEN
FREEZER
THAW
REFRIG.
DRY
STORAGE
CAN WASH
LOADING
DOCK
RECEIVING
RECYCLING
INSUL.
CONTAINER
DROP OFF
FECFEC
FEC
FEC
FEC
FEC-KFEC-K
FEC
FEC
FEC-K
FEC-K
FEC-K
FEC-K
FEC-K FEC
1FEC
EXIT CAPACITY BASED ON
VESTIBULE WIDTH AT
NARROWEST POINT 5'-0"
FE
FE
FEC
FEC
TRAVEL DISTANCE = 80'
TRAVEL DISTANCE = 103' 2
TRAVEL DISTANCE = 168'
TRAVEL DISTANCE = 151'
TRAVEL DISTANCE = 117'
K
VESTIBULE
D.8
D.7
E.7
E.8
C2
C1
REFRIG.
ELECTRICAL
ROOM
STORAGE
VESTIBULE
113A
TRAY
RETURN
114A
TRAY
RETURN
7 7
C.1
C.9
D.9
NOTES:
TYPE 'ABC' FIRE EXTINGUISHER TO BE
INSTALLED IN SEMI-RECESSED MOUNTED FEC.
TYPE 'K' FIRE EXTINGUISHER TO BE INSTALLED
IN SEMI-RECESSED MOUNTED FEC.
KEY BOX (FIRE) - MONITORED BY FIRE ALARM
SYSTEM. COORDINATE FINAL LOCATION WITH
INSTALLATION AHJ/ FIRE CHIEF.
BACK FLOW TEST ASSEMBLY.4
EDGE OF CONCRETE SLAB.5
TYPE 'ABC' FIRE EXTINGUISHER TO BE
INSTALLED IN SURFACE MOUNTED FEC.
OUTLINE OF EXHAUST HOOD.7
OUTLINE OF CONDENSATE HOOD.8
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
LS101
VOLUME 4
BU
IL
D
IN
G A
N D
L
IF
E
SA
F E
TY
C O
D E
PL
AN
A
IT
B A
R
RA
C K
S
CO
M
PL
EX
P H
A
SE
D
IN
IN
G
F A
C I L
IT
Y
N O
R
FO
LK
D
I S
TR
IC
T
N O
R
FO
LK
, V
A
S
UB
M
IT
TA
L
R C
N
EA
M
D
AG
M
AP
J
AN
PR
O
JE
C T
N U
M
BE
R
C O
N
TR
AC
T
N O
LS
1 0
1-
F O R
T L E
E, V
I R G
IN
I A
3/32" = 1'-0"
BUILDING AND LIFE SAFETY CODE PLAN
A
B
KEY PLAN
NO SCALE
NORTH
C
D
8'0' 16' 24'
SCALE: 1/8" = 1' - 0"
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
2 OFFICE SPACES AVAILABLE
OFFICE SPACE IN YELLOW
1115006653CIV
Highlight
1115006653CIV
Highlight
1115006653CIV
Highlight
1115006653CIV
Highlight
MANAGER'S OFFICE
1115006653CIV
Highlight
OFFICE ADMIN