Attachment 7 - Architectural 2 of 4.pdf appears to be an architectural drawing or set of plans related to Solicitation Number 36C77624R0087 for the construction of a replacement outpatient clinic at the US Coast Guard Air Station for the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation is for a new Community Based Outpatient Clinic (CBOC) for the Providence VA Medical Center. The document likely contains detailed specifications and designs for the construction project, though it does not provide any further information about the required products, services, timeline, pricing, or other key details of the solicitation.
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Outpatient Clinic - Cape Cod Bourne, Massachusetts
U.S. Department of Veterans Affairs
1' - 10"
4"
DIE CUT ALUMINUM, LETTERING
FONT TO BE HELVETICA BOLD
PER THE VA FONT GUIDE
SIGN FACE
EQ EQ
ALL TEXT SHOULD BE CENTERED
HORIZONTALLY ON THE SIGN
FACE, UNLESS OTHERWISE NOTED
STREET SIDE
TOOTH WALL CMU
INTO PIER CMU
/2
CMU CORE
AIR SPACE
FACE BRICK WALL
GRANITE VENEER
OVER CONCRETE BASE
AE209
B8
2' - 4" 12' - 0" 2' - 4"
AE209
F8
2' - 4" 12' - 0" 2' - 4"
GRANITE CAP
GRANITE
VENEER OVER
CONCRETE BASE
GRANITE CAP
Outpatient Clinic - Cape Cod Bourne, Massachusetts
U.S. Department of Veterans Affairs
DIE CUT ALUMINUM, LETTERING
FONT TO BE HELVETICA BOLD PER
THE VA FONT GUIDE, SEE
GRADE, SEE CIVIL
DRAWINGS FOR SLOPE
WEEP, ONE
PER FACE
OF COLUMN
WEEPS ON FACE OF
SIGN @ 2'-0" O.C.
B1/ AE209
C1
AE209
C6
AE209
1' - 9"
STREET SIDE
4"
1 1/2"
8"
6"3"
1' - 7"
1 1/2"
2"
STAINLESS STEEL ANCHOR @
2' - 0" O.C., EPOXY TO COLUMN
GRANITE CAP
BOND BEAM BLOCK
COLUMN BEYOND
FACE BRICK WALL
CMU CORE, 8X8X16 BLOCKS.
WIRE MESH REINFORCING
EVER 2 COURSES
AIR SPACE
DOVETAIL BRICK ANCHORS,
16" O.C. VERTICAL SPACING
2" GRANITE REVEAL
OVER CONCRETE BASE
GRADE
1" X 1" CHAMFERED EDGE
WEEPS
CONT. MTL FLASHING
ADHERED AVB MEMBRANE
FLASHING OVER MTL FLASHING
CONT. CAVITY
DRAINAGE MESH
1' - 10"
REBAR IN FULLY
GROUTED CELLS. SEE
STRUCTURAL DRAWINGS
T Y
P
VERTICAL SLOTTED DOVETAIL
ANCHOR AT 2' - 0" O.C. - BEYOND
CONCRETE BASE, SEE
STRUCTURAL DRAWINGS
1/2" 1/2"
1 1/2"
SAW-CUT DRIP, ALL
SIDES OF GRANITE CAP
/4
GRANITE CAP, 1 1/2"
OVERHANG AT ALL SIDES
DETAIL APPLIES TO ALL GRANITE
CAPS AT COLUMNS AND SIGNAGE
GRANITE BASE WITH MITERED
CORNERS, EXTENDING UP
ABOVE GRADE - T.U.O.N.
FACE BRICK COLUMN
GRADE
2' - 6"
GRANITE CAP
2' - 4"
CHAMFERED EDGE
SEE STRUCTURAL DRAWINGS
FOR FOUNDATION DETAILS
WEEP, ONE PER
FACE OF COLUMN
2' - 7"
1 1/2"
2' - 6"
FACE BRICK COLUMN
ABOVE, CENTERED
ON CONCRETE BASE
2" GRANITE REVEAL
OVER CONCRETE BASE
MITERED CORNERS, TYP.
CONCRETE BASE, SEE
STRUCTURAL DRAWINGS
STAINLESS STEEL SLOTTED
DOVETAIL ANCHOR AND
STRAP, T.U.O.N.
EQ EQ
GRANITE BASE BEYOND
FACE BRICK COLUMN,
CENTERED ON GRANITE BASE
2' - 4"
CMU CORE, (2) 8X16 BLOCKS. ALTERNATE
BLOCK DIRECTION EACH COURSE.
REBAR IN FULLY
GROUTED CELLS. SEE
STRUCTURAL DRAWINGS
AIR SPACE
2" GRANITE REVEAL OVER
CONCRETE BASE, EXTENDING
UP ABOVE GRADE
FACE BRICK COLUMN
GRADE
2' - 6"
GRANITE CAP,
SMOOTH FINISH
1" X 1" CHAMFERED EDGE
SEE STRUCTURAL DRAWINGS
FOR FOUNDATION DETAILS
CMU CORE,
8X8X16 BLOCKS
AIR SPACE
BRICK TIES, 16" O.C.
VERTICAL SPACING
1 1/2"
2' - 4"
WEEPS
CONT. MTL FLASHING
ADHERED AVB
MEMBRANE FLASHING
OVER MTL FLASHING
CONT. CAVITY
DRAINAGE MESH
STAINLESS STEEL ANCHOR,
EPOXY TO COLUMN
REBAR, FOR REINFORCING
DETAILS, SEE STRUCTURAL
DRAWINGS
2' - 7"
NOTE: TOP COURSE
GROUTED SOLID
VERTICAL SLOTTED DOVETAIL
ANCHOR, SEE C8/ AE209
B8
AE209
C8
AE209
AE209
A8
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/3
/2
:4
:1
P M
AE209
ENTRY SIGN ELEVATIONS AND
DETAILS
REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB BRS
100% CONSTRUCTION
DOCUMENTS
1" = 1'-0"
B1 SIGNAGE DIMENSIONS
1" = 1'-0"
C1 SIGNAGE - PLAN
1" = 1'-0"
F1 SIGNAGE - ELEVATION - STREET SIDE
1" = 1'-0"
C6 SIGNAGE - SECTION
3" = 1'-0"
A8 GRANITE CAP DETAIL
1" = 1'-0"
F8 BRICK COLUMN - ELEVATION
1" = 1'-0"
C8 BRICK COLUMN BASE - PLAN
1" = 1'-0"
B8 BRICK COLUMN - PLAN
1" = 1'-0"
F6 BRICK COLUMN - SECTION
Revisions Date
LEVEL 1
119' - 0"
TRUSS BEARING
134' - 0"
B C D G H
F1
AE301
AE302
F1
F.9
F7
AE301
AE302
F7
E FC.6C.5B.7 D.5D.6D.7 E.5 F.5 F.7 H.1C.3 D.3 D.9 F.3B.8 C.7
STORAGE MEDICAL &
GENERAL
CORRIDOR
CLOSET
EXAM
EXAM / TELE-HEALTH
CORRIDOR
PRINT ALCOVE
TOILET PROC.
PROCEDURE ROOM,
GENERAL
EXAM / TRIAGE
CORRIDOR
RECEPTION
WORKROOM
RECEPTION
RECEPTION
CORRIDOR
WAITING
B.2
LOW ROOF T.O.
BEAM
129' - 2"
T.O.F.
114' - 4"
F.6F.2
5/8" GYP CONTINUOUS
ON CFM FRAMING AT
UNDERSIDE OF PITCHED
ROOF TRUSSES, TYP.
LEVEL 1
119' - 0"
TRUSS BEARING
134' - 0"
BCD A
F1
AE301
AE302
F3
F.9
F7
AE301
EF C.6C.5 B.7D.5D.6D.7E.5F.5F.7H.1H.2 A.4C.3D.3D.9F.3 B.8C.7
MULTI-PURPOSE
ROOM
GROUP THERAPY
ROOM, MENTAL
HEALTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
122 CORRIDOR
ELECTRICAL ROOM
MECHANICAL
B.2
LOW ROOF T.O.
BEAM
129' - 2"
T.O.F.
114' - 4"
F.6 F.2
AE302
F8
B1
AE302
LEVEL 1
119' - 0"
TRUSS BEARING
134' - 0"
1 2 3 4 5
B1
AE301
D1
AE301 AE302
F5
AE502
A1
1.3 1.5 1.9 2.52.4 2.7 3.3 3.63.1 3.7
CONSULT RM,
MENTAL HLTH
CORRIDOR
EXAM / TELE-HEALTH
CORRIDOR
TEAM WORK AREA
CORRIDOR
164 PROCEDURE ROOM,
GENERAL
CORRIDOR
ULTRASOUND
LOW ROOF T.O.
BEAM
129' - 2"
T.O.F.
114' - 4"
AE302
F8
Sim
5/8" GYP CONTINUOUS
ON CFM FRAMING AT
UNDERSIDE OF PITCHED
ROOF TRUSSES, TYP.
LEVEL 1
119' - 0"
TRUSS BEARING
134' - 0"
2 3 4
B1
AE301
62.52.4 2.7 3.3 3.63.1 3.7
AE403
F8
VOLUNTEER
WAITING
VESTIBULE
T.O.F.
114' - 4"
10' - 1 3/8"
F1
AE303
5/8" GYP CONTINUOUS
ON CFM FRAMING AT
UNDERSIDE OF PITCHED
ROOF TRUSSES, TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/2
/2
:4
:5
P
M
AE301
BUILDING SECTIONS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB BRS
100% CONSTRUCTION
DOCUMENTS
1/8" = 1'-0"
B1 BUILDING SECTION - A
1/8" = 1'-0"
D1 BUILDING SECTION - B
1/8" = 1'-0"
F1 BUILDING SECTION - C
1/8" = 1'-0"
F7 BUILDING SECTION - D
TRUSS BEARING
134' - 0"
H
AE502
F4
AE502
D7
ALUM STOREFRONT SYSTEM
E4
E1
11"
11"
12"
T.O.F.
114' - 4"
AE605
D9
LEVEL 1
119' - 0"
F.9
AE502
F7
AE502
C9
TPO ROOFING
/4
E3
LOW ROOF T.O.
BEAM
129' - 2"
11"
T.O.F.
114' - 4"
AE605
D6
LEVEL 1
119' - 0"
TRUSS BEARING
134' - 0"
4 5
AE502
D4
TPO ROOFING
STANDING SEAM
ROOFING
E3
LOW ROOF T.O.
BEAM
129' - 2"
5"
12"
11"
11"
T.O.F.
114' - 4"
AE502
F7
Sim
LEVEL 1
119' - 0"
TRUSS BEARING
134' - 0"
B
AE502
D1
E2
T.O.F.
114' - 4"
AE502
F9
LEVEL 1
119' - 0"
A
LOW ROOF T.O.
BEAM
129' - 2"
T.O.F.
114' - 4"
E2
AE502
F9
Sim
AE503
D4
11"
LEVEL 1
119' - 0"
3.1
T.O.F.
114' - 4"
AE503
D9
AE503
F9
BRICK VENEER W/ DOVETAIL
MASONRY ANCHORS.
BRICK TO MATCH BUILDING FACADE.
REINFORCED CONCRETE SCREEN WALL
SEE STRUCTURAL DRAWINGS
PAINT EXPOSED SURFACES MIN,
TWO COATS OF ENAMEL TO
MATCH THE LAP SIDING COLOR
CALLED FOR IN BUILDING COLOR
SCHEDULE.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/3
/2
:4
:2
P M
AE302
EXTERIOR WALL SECTIONS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB BRS
100% CONSTRUCTION
DOCUMENTS
1/2" = 1'-0"
F1 EXTERIOR WALL SECTION - A
1/2" = 1'-0"
F3 EXTERIOR WALL SECTION - B
1/2" = 1'-0"
F5 BUILDING SECTION - C
1/2" = 1'-0"
F7 BUILDING SECTION - A
1/2" = 1'-0"
F8 BUILDING SECTION - MECH RM
1/2" = 1'-0"
B1 EXTERIOR SECTION - SCREEN WALL
TRUSS BEARING
134' - 0"
BENCHMARK
134' - 6"
HH.1H.2
LOW ROOF T.O.
BEAM
129' - 2"
T.O.F.
114' - 4"
11"
12"
E4
E1
ALUM STOREFRONT SYSTEM
9"
AE605
D9
AE605
F9
AE503
F1
AE403
F6
Sim
LEVEL 1
119' - 0"
LOW ROOF T.O.
BEAM
129' - 2"
T.O.F.
114' - 4"
E1
E2
11"
TPO ROOFING
AE605
D9
AE605
F9
AE502
C9
Sim
LEVEL 1
119' - 0"
TRUSS BEARING
134' - 0"
BENCHMARK
134' - 6"
4 5 6
LOW ROOF T.O.
BEAM
129' - 2"
T.O.F.
114' - 4"
5"
12"
E2
E1
11"
AE503
B7
Sim
AE503
F7
Sim
AE502
F1
Sim
AE503
F4OH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/3
/2
:4
:3
P M
AE303
EXTERIOR WALL SECTIONS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB BRS
100% CONSTRUCTION
DOCUMENTS
1/2" = 1'-0"
F1 EXTERIOR SECTION - CANOPY
1/2" = 1'-0"
F4 EXTERIOR SECTION - LOW ROOF
1/2" = 1'-0"
F6 EXTERIOR SECTION - SMALL CANOPY
FEC
55 SF
TOILET PATIENT
AE401
D1 1.9
D.3
E2 ø 5' - 6
D2
E1
M4C
M4C
M6M6
/8
2"
7' - 3 1/2"
62 SF
TOILET STAFF
1' - 0" 7' - 6"
AE401E5
E4
M6
M4C
M4C
2.5
2.4 ø 5' - 6"
D4
D5
M6
60 SF
TOILET PUBLIC
59 SF
TOILET PUBLIC
/2
1' - 10" 7' - 7 1/2" 7' - 7 1/2"
AE401 D8
E7
E8
M6
M4C
M6
111110
FF.5F.7
2.5
2.4
F.3 ø 5' - 6 ø 5' - 6
D7
1' - 10" 7' - 1" 1' - 4" 6' - 10"
/2
/2
/2
M4C
M4C
M4C
M4C
M4C
M4C
E Q
E Q
F.6 F.2
TBA-8
TBA-6
TBA-6 TBA-9
TBA-1
TBA-11
P-6
TBA-1
TBA-2
TBA-11 6
C W
T -2
P-6
TBA-3
TBA-4
C W
T -2
TBA-5
P-6
TBA-2
TBA-1
TBA-11
TBA-5
C W
T -2
P-6
TBA-3
TBA-4
C W
T
-2 TBA-5
P-6
TBA-9
C W
T -2
P-6
TBA-1
TBA-3
TBA-4
TBA-2
TBA-11
TBA-5
P-6
ABAAS HEIGHTS NOTE:
MOUNTING HEIGHTS SHOWN HERE ARE CLEARANCES
REQUIRED FROM FINISHED FLOOR AND WALL MATERIALS.
WALL HUNG
A.D.A. TOILET
18"x20" WALL
HUNG LAVATORY
TOILET TISSUE
DISPENSER
(DOUBLE)
OS/CI
TBA - 1
GRAB BARS, CS/CI
NOTE: GRAB BAR DIMS TO TOP
OF GRIPPING SURFACE;
TBA-2 INCLUDES (3) GRAB BARS;
WIDTH OF REAR BAR VARIES
TBA - 2
MIN CLEARANCE
FOR DISPENSERS
3' - 6"
1' - 0"
/8
MIN CLEARANCE
FOR DISPENSERS
3' - 0"
6"
/2
MIN, UNO
1' - 3"
M
IN
MIRROR, CS/CI
NOTE: MIRROR DIMS TO
BOTTOM OF
REFLECTIVE SURFACE
TBA - 3
M A
X
COAT/ROBE
HOOK, CS/CI
PAPER TOWEL
DISPENSER,
OS/CI
LIQUID SOAP
DISPENSER,
OS/CI
WATER
FOUNTAIN
TBA - 4 TBA - 5 TBA - 6
/2
M
IN
M A
X
MIN
1' - 3"
M A
X
M A
X
T O
C E
N T
E R
O F
C O
N T
R O
L S
T O
C E
N T
E R
O F
C O
N T
R O
L S
MIN
1' - 3"
MIN
1' - 3"
MOP AND
BROOM
HOLDER, CS/CI
8"
9"
1' - 6"
TBA - 7
DIAPER
CHANGING
STATION, OS/CI
T .O
O
P E
N
C H
A N
G
IN
G
S U
R F
A C
E
TBA - 8
T .O
O
P
O P
E R
A B
L
A R
T S
SANITARY
DISPENSER,
OS/CI
TBA - 9
SPECIMEN
PASS-THRU,
CS/CI
TBA - 10
T .O
O
P
E R
A B
R
T S
3' - 4"
2' - 0"
6"
SANITARY
DISPOSAL,
OS/CI
TBA - 11
NURSE CALL
TYP AT TOILET
ROOMS
CS/CI
SHARPS
DISPOSAL,
CS/CI
TBA - 11
T .O
O
P
E R
A B
R
T S
1' - 6"
"4
C L E
A R
"ALIGN
TBA-6
TBA-6
P-6
P-6
P-6
TBA-6
TBA-6
TBA-1
P-6 P-6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/3
/2
:4
:4
P M
AE401
ENLARGED RESTROOM PLANS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB AM
100% CONSTRUCTION
DOCUMENTS
3/8" = 1'-0"
B1 ENLARGED PLAN - TOILET PATIENT 125
3/8" = 1'-0"
B4 ENLARGED PLAN - TOILET STAFF 146
3/8" = 1'-0"
B7 ENLARGED PLAN - TOILET PUBLIC 110, 111
3/8" = 1'-0"
D8 TLT PUBLIC 111 - EAST
3/8" = 1'-0"
E7 TLT PUBLIC 111 - SOUTH
3/8" = 1'-0"
E8 TLT PUBLIC 111 - WEST
3/8" = 1'-0"
E4 TLT STAFF 146 - SOUTH
3/8" = 1'-0"
E5 TLT STAFF 146 - WEST
3/8" = 1'-0"
D1 TLT PAT. 125 - NORTH
3/8" = 1'-0"
E2 TLT PAT. 125 - WEST
1/4" = 1'-0"
F1 TBA MOUNTING HEIGHTS
3/8" = 1'-0"
D2 TLT PAT. 125 - EAST
3/8" = 1'-0"
E1 TLT PAT. 125 - SOUTH
3/8" = 1'-0"
D4 TLT STAFF 146 - NORTH
3/8" = 1'-0"
D5 TLT STAFF 146 - EAST
3/8" = 1'-0"
D7 TLT PUBLIC 111 - NORTH
TOILET PROC.
8' - 6" 1' - 6"
/2
/2
TOILET STAFF
AE402 A6
AE402 C6
M4C
M4C
M6
M6
D.5D.6D.7 D.3
3.3
3.1
C4
A4 ø 5' - 6" ø 5' - 6"
A9
A7
C9
C7
E Q
E Q
E Q
E Q
59 SF
TOILET WMN'S
69 SF
TOILET PATIENT
9' - 1"
AE402
AE402
F4
F9
D7
D9
M6M4C
M4C
M6
E.5
3.6
3.7 ø 5' - 6"
BARIATRIC
ø 6' - 0"
D4
D6
F6
F7
1' - 6"
4' - 0"
TBA-6
TBA-2
TBA-11
TBA-1
TBA-6
P-6
TBA-3
TBA-4
C W
T -2
P-6
TBA-5
P-6 P-6
TBA-6
TBA-2
TBA-11
TBA-1
TBA-6
P-6
TBA-3
TBA-4
C W
T -2
P-6
TBA-5
P-6 P-6
TBA-6
TBA-6
P-6
TBA-9
P-6
TBA-3
TBA-4
C W
T
-2TBA-5
P-6
TBA-2
TBA-1TBA-116
C W
T -2
P-6
TBA-3
C W
T -2
TBA-5
TBA-4
P-6 P-6
P-6
TBA-9
TBA-2
TBA-1
TBA-10
TBA-11
TBA-6
TBA-6
P-6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/3
/2
:4
:5
P M
AE402
ENLARGED RESTROOM PLANS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB AM
100% CONSTRUCTION
DOCUMENTS
3/8" = 1'-0"
C1 ENLARGED PLAN - TLT PROC 142 TLT STAFF 148
3/8" = 1'-0"
F1 ENLARGED PLAN - TLT WMNS 136, TLT PATIENT 134
3/8" = 1'-0"
A4 TLT PROC. 142 - NORTH
3/8" = 1'-0"
A6 TLT PROC. 142 - EAST
3/8" = 1'-0"
A7 TLT PROC. 142 - SOUTH
3/8" = 1'-0"
A9 TLT PROC. 142 - WEST
3/8" = 1'-0"
C4 TLT STAFF 148 - NORTH
3/8" = 1'-0"
C6 TLT STAFF 148 - EAST
3/8" = 1'-0"
C7 TLT STAFF 148 - SOUTH
3/8" = 1'-0"
C9 TLT STAFF 148 - WEST
3/8" = 1'-0"
D4 TLT WOMEN'S 136 - NORTH
3/8" = 1'-0"
D6 TLT WOMEN'S 136 - EAST
3/8" = 1'-0"
D7 TLT WOMEN'S 136 - SOUTH
3/8" = 1'-0"
D9 TLT WOMEN'S 136 - WEST
3/8" = 1'-0"
F4 TLT PAT. 134 - NORTH
3/8" = 1'-0"
F6 TLT PAT. 134 - EAST
3/8" = 1'-0"
F7 TLT PAT. 134 - SOUTH
3/8" = 1'-0"
F9 TLT PAT. 134 - WEST
J
ML
J
GH
F.9
F7
AE301
F.7H.1H.2
3.3
3.6
3.7
7' - 6" 10' - 6" 5' - 0" 8' - 9"
F1
AE303
/4
" / 1
/4
1/4" / 12"
1/4" / 12"
ROOF DRAIN, TYP.
1' - 10"
GH
F.9
F7
AE301
F.7H.1H.2
3.3
3.6
3.7
F1
AE303
/2
/2
7' - 3 1/2" 16' - 9" 7' - 3 1/2"
VESTIBULE
CORRIDOR
2' - 4" 1' - 8" 11' - 6" 3' - 3" 6' - 3"
AE501
D5
LEVEL 1
119' - 0"
TRUSS BEARING
134' - 0"
T.O.F.
114' - 4"
3' - 0" 7' - 6"
AE403
F6
AE403
F4
TAPERED HSS SHOWN BEYOND
SEE STRUC DWGS
WOOD LOOK PHENOLIC RESIN
PLANK SYSTEM ON CONTINUOUS
AVB ON 1/2" EXTERIOR GRADE
PLYWOOD
ROOF DRAIN LEADER
SEE MEP DWGS
ROOF MEMBRANE ON
COVERBOARD ON TAPERED RIGID
INSULATION ON COVERBOARD ON
METAL DECK
ROOF DRAIN
/2
2' - 6 5/8" 7' - 0"
/2
G H
F.9
F7
AE301
F.7
H.1H.2
3.3
3.6
3.7
F1
AE303
/2
2 1/2" / 12"
2 1/2" / 12"
/2
11' - 10 1/2"
7' - 0" 15' - 6" 8' - 3"
PHENOLIC RESIN
PANEL SOFFIT, TYP.
EXPOSED BEAM, SEE
STRUCTURAL, TYP.
METAL COPING, TYP.
RECESSED LIGHT FIXTURE, COORDINATE LOCATION
TO FALL FULLY IN A SINGLE SOFFIT PLANK, TYP
3/4" / 12"
/8 "1 /2
/8
/4
3" 3"
TAPERED STEEL BEAM
SEE STRUC DWGS
TPO ROOF MEMBRANE OVER 1/2"
COVERBOARD OVER TAPERED
RIGID INSULATION OVER 1/2"
PLYWOOD ON STL DECKING
SEE STRUC DWGS
MTL DRIP EDGE FLASHING
PREFIN. MTL FASCIA
TO MATCH ROOF TRIM
2x BLOCKING
2x BLOCKING
TAPERED HSS SHOWN BEYOND
SEE STRUC DWGS
WOOD LOOK PHENOLIC RESIN
PLANK SYSTEM ON CONTINUOUS
AVB ON 1/2" EXTERIOR GRADE
PLYWOOD
2 1/2" / 12"
CFM FRAMING SUPPORT FOR
ANGLED SOFFIT
TRUSS BEARING
134' - 0"
COUNTERFLASH WITH AVB
TERMINATION BAR, SET IN
SEALANT
TWO PART SNAP LOCK
FLASHING WITH 8" LEG UP
WALL
3/4" EXTERIOR GRADE
PLYWOOD
ROOF MEMBRANE TO
WRAP UP FACE OF WALL
12" MIN
M
IN
1 1/8"
12"
E4
ROOF MEMBRANE ON
COVERBOARD ON TAPERED
RIGID INSULATION ON
COVERBOARD ON METAL DECK
STEEL BEAM
SEE STRUC DWGS
WOOD LOOK PHENOLIC RESIN
PLANK SYSTEM ON CONTINUOUS
AVB ON 1/2" EXTERIOR GRADE
PLYWOOD
/8
RABBETED FIBER CEMENT TRIM,
1x4
CFM FRAMING SUPPORT FOR
SOFFIT, HUNG FROM BEAM
LEVEL 1
119' - 0"
/2
/2
/2
2' - 2" 8" 6' - 8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/3
/2
:4
:5
P M
AE403
ENTRANCE CANOPY PLANS,
SECTIONS & DETAILS
REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB BRS
100% CONSTRUCTION
DOCUMENTS
1/4" = 1'-0"
C1 ENLARGED ROOF PLAN
1/4" = 1'-0"
F1 ENLARGED ENTRANCE PLAN
1/2" = 1'-0"
F8 BUILDING SECTION @ CANOPY
1/4" = 1'-0"
C4 ENLARGED RCP
1 1/2" = 1'-0"
F6 CANOPY ROOF EDGE
1 1/2" = 1'-0"
F4 CANOPY ROOF TO WALL
Revisions Date
1/2" = 1'-0"
B8 CANOPY COLUMN DIMENSIONS
3 5/8" NORMAN BRICK
MASONRY VENEER
CONCRETE COLUMN, SEE
STRUCTURAL DWGS.
STEEL COLUMN ABOVE
SEE STRUCTURAL DWGS.
H.2
SOLID GROUT BEHIND BRICK
2' - 3 5/8"
EQ EQ
9" 9"
E Q
E Q
/8
1' - 0" 5"
E2
E4
E4
M2C
M2C
M2C
TOP OF BRICK SILL
SHOWN BELOW
SIDING TO EXTEND BEHIND
TRIM 3/8", TYP.
MITERED CORNERS, TYP.
CONTINUOUS 3/4" PLYWOOD
3" HORIZONTAL
FIBERGLASS "Z" FURRING,
SHOWN DASHED
CONTINUOUS SELF
ADHERED AVB
STL COLUMN
SEE STRUCTURAL DRAWINGS
5/8" GYP ON 2 1/2" MTL STUDS
F.5
C.6 C.5
TOP OF BRICK SILL
SHOWN BELOW
SIDING TO EXTEND BEHIND
TRIM 3/8", TYP.
MITERED CORNERS, TYP.
CONTINUOUS 3/4" PLYWOOD
3" HORIZONTAL
FIBERGLASS "Z" FURRING,
SHOWN DASHED
CONTINUOUS SELF
ADHERED AVB
6" 8" 3"
6" 5"
E4
E4
M2C
M2C
STL COLUMN
SEE STRUCTURAL
DRAWINGS
5/8" GYP ON 2 1/2"
MTL STUDS
HH.1
2.7
11" 5"
TOP OF BRICK SILL
SHOWN BELOW
SIDING TO EXTEND BEHIND
TRIM 3/8", TYP.
MITERED CORNERS, TYP.
CONTINUOUS 3/4" PLYWOOD
3" HORIZONTAL
FIBERGLASS "Z" FURRING,
SHOWN DASHED
CONTINUOUS SELF
ADHERED AVB
STL COLUMN
SEE STRUCTURAL
DRAWINGS
E4
M2C
M2C M2C
E4
E4
F
TOP OF BRICK SILL
SHOWN BELOW
LAP SIDING SYSTEM
3" HORIZONTAL
FIBERGLASS "Z"
FURRING, SHOWN
DASHED
CONTINUOUS SELF
ADHERED AVB
HIGH PRESSURE
LAMINATE PANEL
SYSTEM
STL COLUMN
SEE STRUCTURAL
DRAWINGS
M6
E3
E3
E2
11"
F
TOP OF BRICK SILL
SHOWN BELOW
LAP SIDING SYSTEM
3" HORIZONTAL
FIBERGLASS "Z" FURRING,
SHOWN DASHED
CONTINUOUS SELF
ADHERED AVB
HIGH PRESSURE
LAMINATE PANEL
SYSTEM
E3
M6
E3
E2
11" 3"
F.7
1.5
ALIGNMENT GUIDE
CAULKING BETWEEN
WALL AND JAMB
FOLDING PANEL
SYSTEM
JAMB FINISH
SAME AS PANELS
BLOCKINGM6
M4
STL COLUMN
SEE STRUCTURAL DWGS
F
1.5
/4
/4
2' - 5" 3"
BLOCKING AS
REQUIRED
PANELS IN
FOLDED
POSITION
C L
E A
R
CAULKING
BETWEEN
JAMB AND
WALL
JAMB FINISH
SAME AS
PANELS
M4 M2C
M4
M4
M6
1' - 3"
END WALL
GUARD,
TYP.
F.9
E3
E3
M2C
M2C
5" 10" 1
/2
STL COLUMN
SEE STRUCTURAL
DRAWINGS
OVERFLOW ROOF DRAIN
SEE MEP DRAWINGS
5/8" GYP ON 2 1/2"
MTL STUDS
HH.1
2.5
2.4
E4
E4
E4
M2C
M2C
11" 1' - 8" 5"
TOP OF BRICK SILL
SHOWN BELOW
SIDING TO EXTEND BEHIND
TRIM 3/8", TYP.
MITERED CORNERS, TYP.
CONTINUOUS 3/4" PLYWOOD
3" HORIZONTAL
FIBERGLASS "Z" FURRING,
SHOWN DASHED
CONTINUOUS SELF
ADHERED AVB
STL COLUMN
SEE STRUCTURAL
DRAWINGS
M4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/3
/2
:4
:0
P M
AE501
PLAN DETAILS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB BRS
100% CONSTRUCTION
DOCUMENTS
1 1/2" = 1'-0"
D5 ENTRY COLUMN DETAIL
1 1/2" = 1'-0"
B1 COLUMN ENCLOSURE DETAIL
1 1/2" = 1'-0"
B5 COLUMN ENCLOSURE DETAIL
1 1/2" = 1'-0"
D7 COLUMN ENCLOSURE DETAIL
1 1/2" = 1'-0"
F3 COLUMN ENCLOSURE DETAIL
1 1/2" = 1'-0"
F5 COLUMN ENCLOSURE DETAIL
1 1/2" = 1'-0"
F7 OPERABLE PARTITION DETAIL
1 1/2" = 1'-0"
F9 OPERABLE PARTITION DETAIL
1 1/2" = 1'-0"
B3 COLUMN ENCLOSURE DETAIL
1 1/2" = 1'-0"
B7 COLUMN ENCLOSURE DETAIL
TRUSS BEARING
134' - 0"
4 5
STANDING SEAM METAL
ROOF W/ END CLOSURE
CONT. ROOF
UNDERLAYMENT
TO LAP OVER AVB
BENT STEEL PLATE
CFM OUTRIGGER
METAL DRIP EDGE
FIBER CEMENT FASCIA
TRIM, 1x12
5/8" PLYWOOD
EXTERIOR GRADE
FIBER CEMENT
SOFFIT PANEL
FIBER CEMENT
TRIM, 1x6
SPRAY FOAM INSULATION
CFM TRUSS,
SEE STRUCTURAL
DRAWINGS, TYP.
LOW ROOF T.O.
BEAM
129' - 2"
RABBETED FIBER
CEMENT
TRIM, 1x4
TERMINATION BAR, SET IN SEALANT
3/4" EXTERIOR
GRADE PLYWOOD
TWO PART SNAP LOCK FLASHING
WITH 8" LEG UP WALL
ROOF MEMBRANE TO WRAP UP
FACE OF WALL 12" MIN
COUNTERFLASH WITH AVB
5"
12"
11" 11"
PREFIN. MTL GUTTER
E3
13' - 0"
T.O. FRAMING
143' - 2"
PREFIN. MTL PARAPET
CAP, TO MATCH METAL
ROOFING
FLASHING
PROVIDE SPACE FOR
CLADDING SYSTEM
VENTILATION
AE502
A9
GUTTER WEDGE
2' - 2"
M
IN
FIBER CEMENT FASCIA
TRIM, 1x4
STEEL FRAMING
SEE STRUC DWGS
F.9
T.O. FRAMING
14' - 0"
ROOF AS SCHEDULED
RUN ROOF AVB OVER
PARAPET AND LAP
WITH WALL AVB
3/4" EXTERIOR
PLYWOOD OVER 2 1/2"
RIGID INSULATION
RUN ROOF MEMBRANE
OVER TOP OF PARAPET
AND LAP OVER AVB
WRAP AVB OVER
LADDER FRAMING
METAL COPING
COLOR TO MATCH
STANDING SEAM ROOF
SPACE PROVIDED FOR
CLADDING ASSEMBLY
VENTILATION
E3
AE502
A9
11"
TRUSS BEARING
134' - 0"
H
STANDING SEAM METAL
ROOF W/ END CLOSURE
CONT. ROOF
UNDERLAYMENT
TO LAP OVER AVB
METAL DRIP EDGE
FIBER CEMENT FASCIA
TRIM, 1x12
5/8" PLYWOOD
EXTERIOR GRADE
FIBER CEMENT
SOFFIT PANEL
FIBER CEMENT
SHINGLES
SPRAY FOAM INSULATION
CFM TRUSS,
SEE STRUCTURAL
DRAWINGS, TYP.
E4
FIBER CEMENT
TRIM, 1x6
RABBETED FIBER
CEMENT
TRIM, 1x4
11"
11"
12"
2' - 11 5/8"
CFM OUTRIGGER
R1
FIBER CEMENT FASCIA
TRIM, 1x4
TRUSS BEARING
134' - 0"
STANDING SEAM METAL
ROOF W/ END CLOSURE
CONT. ROOF UNDERLAYMENT
TO LAP OVER AVB
CFM TRUSS, SEE STRUCTURAL
DRAWINGS, TYP.
BENT STEEL PLATE
SPRAY FOAM INSULATION
METAL DRIP EDGE
CFM OUTRIGGER
FIBER CEMENT
FASCIA TRIM, 1X12
5/8" PLYWOOD
EXTERIOR GRADE
FIBER CEMENT
SOFT PANEL
FIBER CEMENT
TRIM, 1X6
RABBETE FIBER
CEMENT TRIM, 1X4
COUNTERFLASH WITH AVB
TERMINATION BAR, SET IN
SEALANT
TWO PART SNAP LOCK
FLASHING WITH 8" LEG UP
WALL
3/4" EXTERIOR GRADE
PLYWOOD
ROOF MEMBRANE TO
WRAP UP FACE OF WALL
12" MIN
FIBER CEMENT
FASCIA TRIM, 1X4
" M
IN
M
IN
1' - 6"
5"
12"
1/4" 12"
R2
R1
5/8" GYP CONTINUOUS
ON CFM FRAMING AT
UNDERSIDE OF
PITCHED ROOF
TRUSSES, TYP.
LEVEL 1
119' - 0"
H
SSTL THROUGH-WALL
FLASHING TO EXTEND UP
WALL 8" MIN. COUNTER
FLASH WITH AIR BARRIER
MEMBRANE, TYP.
WEEP
MORTAR NET, TYP.
ALUMINUM WINDOW FRAME
CONTINUOUS SEALANT
GWB RETURN BEYOND
SSURF STOOL W/ INTEGRAL
APRON FACE
1/2" PLYWOOD
LVL WINDOW BUCK
BACKER ROD AND SEALANT
11"
E1
T.O.F.
114' - 4"
BRICK SILL W/ ANCHORS IN
MORTAR JOINTS AT 16" O.C.
AE605
F9
SEE DETAIL F9/AE502 FOR TYPICAL
FOUNDATION NOTES AT BRCIK SHELF
T Y
P
LEVEL 1
119' - 0"
F.9
ALUMINUM WINDOW FRAME
CONTINUOUS SEALANT
GWB RETURN BEYOND
SSURF STOOL W/
INTEGRAL APRON FACE
1/2" PLYWOOD
LVL WINDOW BUCK
BACKER ROD AND SEALANT
PERFORATED
ANGLE CLOSURE
E3
GRADE, SEE
CIVIL DWGS
CELLULAR PVC
PROTECTION
BOARD
2" RIGID INSULATION
V A
R
IE
S
T.O.F.
114' - 4"
AVB TO CONTINUE
DOWN FOUNDATION
WALL AND OVERLAP
WITH DAMPPROOFING,
4" MIN.
DAMPPROOFING TO
TOP OF FOOTING
AE605
F6
TYP
11"
1/2" THICK BOND BREAK
WITH SEALANT JOINT
UNDERSLAB VAPOR BARRIER.
CONTINUE OVER TOP OF SLAB
AND OVERLAP WITH WALL AVB
2" RIGID INSULATION
UNDER ENTIRE SLAB
OVER SUBGRADE,
PER GEOTECHNICAL
REPORT
CONCRETE
FOUNDATION, SEE
STRUCTURAL
DRAINAGE, SEE CIVIL
SUBGRADE PER
GEOTECHNICAL
REPORT
8"
1 1/2"
1' - 1"
3/4" PLYWOOD
SHEATHING, TYP.
FILL W/RIGID
INSULATION
BLOCKING, TYP.
FACE OF PLYWOOD
FACE OF INSULATION
ALIGN
ALIGN
NOTE: ANCHOR PARAPET LADDER FRAMING TO STUD WALL. DO NOT ANCHOR TO VENEER.
LEVEL 1
119' - 0"
B
T.O.F.
114' - 4"
SSTL THROUGH-WALL
FLASHING TO EXTEND UP
WALL 8" MIN. COUNTER
FLASH WITH AVB, TYP.
WEEP
MORTAR NET, TYP.
GRADE, SEE CIVIL DWGS.
FILL CAVITY WITH SOLID
GROUT BELOW GRADE
UP TO FLASHING
BRICK SILL W/ ANCHORS
IN MORTAR JOINTS AT
16" O.C.
T Y
P
E2
TYP
11"
8"
1' - 4"
1/2" THICK BOND BREAK
WITH SEALANT JOINT
UNDERSLAB VAPOR
BARRIER. CONTINUE
OVER TOP OF SLAB
AND OVERLAP WITH
WALL AVB
2" RIGID INSULATION
AVB TO CONTINUE
DOWN FOUNDATION
WALL AND OVERLAP
WITH DAMPPROOFING,
4" MIN.
DAMPPROOFING TO
TOP OF FOOTING
2" RIGID INSULATION
UNDER ENTIRE SLAB
OVER SUBGRADE,
PER GEOTECHNICAL
REPORT
CONCRETE
FOUNDATION, SEE
STRUCTURAL
DRAINAGE, SEE CIVIL
SUBGRADE PER
GEOTECHNICAL
REPORT
SSTL THROUGH-WALL
FLASHING TO EXTEND UP
WALL 8" MIN. COUNTER
FLASH WITH AVB, TYP.
1 1/2"
E11
5 5/8"
/4
3 5/8" 2"
/4
B
COPE WALL
ASSEMBLY INTO
MTL DEACK AND
SEAL
GABLE END CAP BY
STANDING SEAM
ROOF MANUF.
STANDING SEAM METAL
ROOF W/ END CLOSURE
1' - 4 1/4" 11 1/256"
FIBER CEMENT
FASCIA TRIM, 1x3
METAL DRIP EDGE
FIBER CEMENT
FASCIA TRIM, 1x8
5/8" PLYWOOD
EXTERIOR GRADE
FIBER CEMENT
SOFFIT PANEL
RABBETED FIBER CEMENT
TRIM, 1x8
E2E2
E2
CFM LADDER FRAMING
SEE STRUC DWGS
TRUSS BEARING
134' - 0"
C.5
1' - 8 1/4"
STANDING SEAM METAL
ROOF W/ END CLOSURE
CONT. ROOF
UNDERLAYMENT
TO LAP OVER AVB
BENT STEEL PLATE
CFM OUTRIGGER
METAL DRIP EDGE
FIBER CEMENT FASCIA
TRIM, 1x12
5/8" PLYWOOD
EXTERIOR GRADE
FIBER CEMENT
SOFFIT PANEL
FIBER CEMENT
TRIM, 1x6
SPRAY FOAM INSULATION
CFM TRUSS,
SEE STRUCTURAL
DRAWINGS, TYP.
RABBETED FIBER
CEMENT
TRIM, 1x4
FIBER CEMENT FASCIA
TRIM, 1x4
8"
12"
R1
1" M
IN
E4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/2
/2
:4
:1
P
M
AE502
SECTION DETAILS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB BRS
100% CONSTRUCTION
DOCUMENTS
1 1/2" = 1'-0"
D4 LOW ROOF TO PITCHED ROOF DETAIL
1 1/2" = 1'-0"
C9 TYPICAL PARAPET DETAIL
1 1/2" = 1'-0"
D7 EAVE DETAIL - 11:12 SLOPE
1 1/2" = 1'-0"
A1 LOW ROOF TO PITCHED ROOF DETAIL
1 1/2" = 1'-0"
F4 WINDOW SILL AT BRICK VENEER
1 1/2" = 1'-0"
F7 WINDOW SILL AT METAL PANEL SYSTEM
3" = 1'-0"
A9 ROOF - PARAPET LADDER FRAMING - TYPE A
1 1/2" = 1'-0"
F9 SECTION DETAIL - WATER TABLE SILL
3" = 1'-0"
D9 BRICK SILL PROFILE DETAIL
1 1/2" = 1'-0"
D1 BUILDING SECTION DETAIL - RAKE
1 1/2" = 1'-0"
F1 EAVE DETAIL - 8:12 SLOPE
3.1
T.O.F.
114' - 4"
SSTL FLASHING TO
EXTEND UP WALL 8" MIN.
COUNTER FLASH WITH AIR
BARRIER MEMBRANE, TYP.
1 1/2" SCHEDULE 40 PVC
WEEP HOLE @ 8'-0" O.C.
LEAVE OPEN JOINT IN
BRICK FOR WEEP HOLE
GRADE, SEE CIVIL DWGS.
FILL CAVITY WITH SOLID
GROUT BELOW GRADE
UP TO FLASHING
FOUNDATION
SEE STRUCTURAL DWGS.
3.1 1' - 2 1/4"
/2
/2 " 4
BRICK COPING
TO MATCH SILLS
ON BUILDING
DRIP
1" MIN
SEALANT
1" MIN
9 1/8" 5 1/8"
2X WOOD
BLOCKING
METAL
CORNER
BEAD
TEAR AWAY "L" BEAD
FLEXABLE SEALANT
INSULATED HOLLOW
METAL DOOR AND
FRAME
5/8" TYPE "X" GWB
6" METAL STUDS
@ 24" O.C. WITH
SPRAY
POLYURETHANE
FOAM
INSULATION
BETWEEN STUDS
3/4" VERTICAL FURRING
SSTL THROUGH-WALL
FLASHING W/ DRIP EDGE,
TO EXTEND UP WALL 8"
MIN., COUNTERFLASH AVB
OVER FLASHING
FIBER CEMENT TRIM, 1X6
3" HORIZONTAL
FIBERGLASS "Z" FURRING
BLOCKING, TYP.
SSTL FLASHING WITH DRIP
EDGE, COUNTER FLASH AVB
OVER FLASHING
BACKER ROD & SEALANT
BOTH SIDES
HM FRAME,
AS SCHEDULED
SSTL FLASHING WITH DRIP
EDGE, COUNTER FLASH
AVB OVER FLASHING
TEAR AWAY "L" BEAD
FOAM IN PLACE
INSULATION
INSULATED HOLLOW
METAL DOOR AND
FRAME
CORNER BEAD AT
ALL OUTSIDE
CORNERS
CONT. INSULATION
5/8" GWB
2x WD
BLOCKING
BACKER ROD AND
SEALANT ALL SIDES
METAL
FLASHING
CONTINUOUS AIR
BARRIER MEMBRANE
LAP SIDING
1x CEMENT BOARD TRIM
/2
"THERMALLY
BROKEN
HANDICAPPED
DOOR SILL
BRICK VENEER
BEYOND
HOLLOW METAL
DOOR FRAME
BEYOND
GYPSUM
RETURN
BEYOND
2x8 WOOD BLOCKING
FOR 2 1/2" MIN. BOLT IN-BED
LAG BOLTS (2) PER BRACKET
6" SPACING
CANOPY HANGING BRACKET
STAINLESS STEEL
FLASHING TURNED UP
FACE OF WALL 4"
CONTINUOUS BED OF
SEALANT
CONTINUOUS BED
OF SEALANT
1X4 VERTICAL WOOD
BLOCKING AT 24" O.C.
CONT. SELF ADHERED AVB
LAP OVER FLASHING
CLAPBOARD, TYP.
PREFABRICATED CANOPY W/
REAR GUTTER SYSTEM AND
HEAT TRACE, SEE PLUMBING
DRAWINGS
NOTE:
G.C. TO COORDINATE BLOCKING AND
CFMF REACTIONS BETWEEN CANOPY
MANUFACTURER AND CFM ENGINEER
WOOD LOOK PLANK
SYSTEM (FIELD INSTALLED)
BASIS OF DESIGN:
TRESPA PURA. CLIPS TO
BE SPACED AT 18" O.C.
PROVIDE J TRIM AT LIGHT
FIXTURE OPENINGS.
NOTE: CFM ENGINEER TO
COORDINATE WITH PREFAB
CANOPY MANUFACTURER
LOADING REQUIREMENTS
A
11"
AE502
A9
ROOF AS SCHEDULED
RUN ROOF AVB OVER
PARAPET AND LAP
WITH WALL AVB
3/4" EXTERIOR
PLYWOOD OVER 2 1/2"
RIGID INSULATION
RUN ROOF MEMBRANE
OVER TOP OF PARAPET
AND LAP OVER AVB
WRAP AVB OVER
LADDER FRAMING
METAL COPING
COLOR TO MATCH
STANDING SEAM ROOF
3.1
BRICK TO WRAP
END WALL
BRICK VENEER OVER
CONCRETE SCREEN
WALL. BRICK TO MATCH
BUILDING FACADES
CONCRETE SCREEN WALL.
SEE STRUCTURAL DRAWINGS
TRUSS BEARING
134' - 0"
BENCHMARK
134' - 6"
HH.1
STANDING SEAM METAL
ROOF W/ END CLOSURE
CONT. ROOF
UNDERLAYMENT
TO LAP OVER AVB
METAL DRIP EDGE
FIBER CEMENT FASCIA
TRIM, 1x12
5/8" PLYWOOD
EXTERIOR GRADE
FIBER CEMENT
SOFFIT PANEL
SPRAY FOAM INSULATION
CFM TRUSS,
SEE STRUCTURAL
DRAWINGS, TYP.
FIBER CEMENT
TRIM, 1x6
RABBETED FIBER
CEMENT
TRIM, 1x4
CFM OUTRIGGER
FIBER CEMENT FASCIA
TRIM, 1x4
11"
12"
M
IN
COUNTERFLASH WITH AVB
TERMINATION BAR, SET IN
SEALANT
TWO PART SNAP LOCK
FLASHING WITH 8" LEG UP
WALL
3/4" EXTERIOR GRADE
PLYWOOD
ROOF MEMBRANE TO
WRAP UP FACE OF WALL
12" MIN
11"2' - 1 1/4"
1"
1 1/8" 12"
CANOPY FRAMING
SEE STRUCTURAL DWGS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/3
/2
:4
:2
P M
AE503
SECTION DETAILS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB BRS
100% CONSTRUCTION
DOCUMENTS
1 1/2" = 1'-0"
F9 EXTERIOR DETAIL - SCREEN WALL FOUNDATION
3" = 1'-0"
D9 EXTERIOR DETAIL - SCREEN WALL COPING
3" = 1'-0"
B7 EXT DOOR - MTL STUD - METAL - HEAD - 1
3" = 1'-0"
D7 EXT DOOR - MTL STUD - METAL - JAMB-1
3" = 1'-0"
F7 DOOR SILL DETAIL - STEEL DOORS AND FRAMES
1 1/2" = 1'-0"
F4 CANOPY DETAIL
1 1/2" = 1'-0"
D4 PARAPET DETAIL
1 1/2" = 1'-0"
B9 EXTERIOR SCREEN WALL DETAIL
1 1/2" = 1'-0"
F1 EXTERIOR SECTION - CANOPY - Callout 1
RETURN GYPSUM BOARD
UP 6" ABOVE CEILING
3 5/8" 25 GA. METAL STUD
FRAMING @ 16" O.C.
SCHEDULED CEILING SEE
REFLECTED CEILING PLAN
FOR SPECIFICATIONS &
HEIGHTS
3 5/8" 25 GA. METAL
CONTINOUS STUD HEADER
RETURN GYPSUM BOARD
UP 6" ABOVE CEILING
LIGHTGLASS SKYLIGHT SYSTEM
PER MANUFACTURER
8' - 10"
LOW ROOF T.O.
BEAM
129' - 2"
RETURN GYPSUM BOARD
UP 6" ABOVE CEILING
3 5/8" or 6" CFMS TO MATCH
ADJACENT WALL THICKNESS.
3 3/8" TO BE USED WHEN NO
WALLS ARE ADJACENT
SCHEDULED CEILING. SEE
REFLECTED CEILING PLAN
FOR SPECIFICATIONS &
HEIGHTS
3 5/8" 25 GA. METAL
CONTINOUS STUD HEADER
2 1/2" STUD BRACE 32" O.C. TIE
TO STRUCTURE ABOVE
5/8" GYPSUM BOARD FASCIA TO
6" ABOVE FINISHED CEILING
SCHEDULED CEILING SEE
REFLECTED CEILING PLAN FOR
SPECIFICATIONS & HEIGHTS
2 1/2" 25 GA. METAL STUD
FRAMING @ 16" O.C.
2 1/2" 25 GA. METAL CONTINOUS
STUD HEADER
CONTINUOUS METAL
CORNER BEAD
5/8" GYPSUM BOARD SOFFIT
SEE RCP
SEE RCP
SCHEDULED
CEILING
SEE RCP
GYPSUM
BOARD SOFFIT
SEE PLAN FOR DIMENSION
SEE RCP
SEE RCP
RETURN GYPSUM BOARD
UP 6" ABOVE CEILING
3 5/8" CFMS
3 5/8" 25 GA. METAL
CONTINOUS STUD HEADER
FWP-1 APPLIED
TO FACE &
FRAMED WITH
QS-1
9"
FWP-2 APPLIED TO
FACE
QS-1
RECEPTION SIDEWAITING SIDE
QS-1
EDGE OF QS-1
BEYOND
SCHEDULED BASE
FINISHED FLOOR
/2
/2
/2
/2
1/2" PLYWOOD ON
2x6 FRAMING
FWP-1
APPLIED TO
FACE &
FRAMED WITH
QS-1
9"
FWP-2
APPLIED TO
FACE
QS-1
WAITING SIDERECEPTION SIDE
QS-1
SCHEDULED BASE
FINISHED FLOOR
EDGE OF QS-1 BEYOND
/2
/2
/2
/2
1/2" PLYWOOD ON
2x6 FRAMING
1' - 6"
SOLID SURFACE
COUNTER
RAKKS INSIDE
WALL MOUNT
COUNTER
SUPPORT
BRACKET OR
EQUAL; ATTACH
TO SIDE OF STUD
SCHEDULED BASE
FINISHED FLOOR
SS-1 CAP
FWP SCHEDULED WALL
PROTECTION
SCHEDULED WALL BASE
BLOCKING AS
REQUIRED
HSS POST BEYOND, SEE
STRUCTURAL
/2
3/8" OVERHANG, TYP
SEE ELECTRICAL
DRAWINGS FOR POWER &
DATA LOCATIONS
F-REVEAL FRY REGLET DRFM625-50 OR EQUAL
WALL AS SCHEDULED
PLAN
N .T
.S
M
A X
A
F F
NOTES:
1. VERIFY ACTUAL OPENING SIZE WITH MANUFACTURER
2. PROVIDE CONTINUOUS RATING FOR CABINETS IN RATED WALLS
SECTION
WALL TYPE AS SCHEDULED
WD BLOCKING
WD BLOCKING
RECESSED FIRE
EXTINGUISHER
CABINET
FIRE EXTINGUISHER
FINISH FLOOR
SCHEDULED WALL
BLOCKING AS
REQUIRED
SHELF
ADJUSTABLE SHELF
BRACKET
ADJUSTABLE SHELF
SUPPORT
SCHEDULED BASE
FINISHED FLOOR
1' - 6"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/3
/2
:4
:2
P M
AE520
INTERIOR DETAILS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB AM
100% CONSTRUCTION
DOCUMENTS
1 1/2" = 1'-0"
F7 GYPSUM SOFFIT @ LIGHTGLASS
3" = 1'-0"
F3 GYPSUM SOFFIT @ TRANSITIONS
3" = 1'-0"
F5 GYPSUM SOFFIT
3" = 1'-0"
F1 GYPSUM SOFFIT @ WAITING
1 1/2" = 1'-0"
D1 CHECK-IN DESK - 30"
1 1/2" = 1'-0"
D3 CHECK-IN DESK - 42"
1 1/2" = 1'-0"
D5 CONCEALED COUNTER BRACKET
1 1/2" = 1'-0"
D7 PARTIAL HEIGHT WALL
1 1/2" = 1'-0"
A9 FULLY RECESSED FIRE EXTIGUISHER CABINET
Revisions Date
1 1/2" = 1'-0"
F9 ADJUSTABLE WALL SHELVES
ATTACH RUNNERS TO
FLOOR @ 24" O.C. AND
WITHIN 1" OF ENDS.
OUTLET BOX
CONTINUOUS
ACOUSTICAL SEALANT
EACH SIDE
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
ONE LAYER OF 5/8"
TYPE "X" GWB. ON
BOTH SIDES OF METAL
STUD @ 16" O.C. SEE
SCHEDULE FOR STUD
SIZES
MINERAL WOOL
INSULATION FRICTION
FIT FOR SOUND
DEADENING. FIT TO
FULL WIDTH OF CAVITY
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
PUTTY BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.
HEAD CONDITION
WALL TYPE VA PARTITION # STUD SIZE
METAL STUD WALL STUD SIZE SCHEDULE
M6 09P62M6 6"
M8 09P82M8 8"
M4 09P42M4 3 5/8"
SMOKE PARTITIONS
TYPICAL PARTITIONS
AE601
B5
CEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
NOTE: MINIMUM SOUND TRANSMISSION CLASS RATING OF STC-49
ATTACH RUNNERS TO
FLOOR @ 24" O.C. AND
WITHIN 1" OF ENDS.
OUTLET BOX
CONTINUOUS
ACOUSTICAL SEALANT
EACH SIDE
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
ONE LAYER OF 5/8"
TYPE "X" GWB. ON
BOTH SIDES OF METAL
STUD @ 16" O.C. SEE
SCHEDULE FOR STUD
SIZES
MINERAL WOOL
INSULATION FRICTION
FIT FOR SOUND
DEADENING. FIT TO
FULL WIDTH OF CAVITY
COVER ALL SIDES OF ALL
TEL. & ELEC. OUTLETS WITH
1/4" THICK ACOUSTICAL
PUTTY BEFORE APPLYING
GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON
OPP. SIDES OF PARTITIONS.
HEAD CONDITION
WALL TYPE VA PARTITION # STUD SIZE
METAL STUD WALL STUD SIZE SCHEDULE
M2 09P22M2 2 1/2"
M6 09P62M6 6"
M8 09P82M8 8"
M4 09P42M4 3 5/8"
AE601
B5
CEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
ATTACH DEFLECTION
TRACK TO STRUCTURE
AT 24" O.C. AND WITHIN
1" OF END.
HEAD CONDITION
PERPENDICULAR TO DECK
GWB PER
PARTITION TYPE
CONTINUOUS ACOUSTICAL JOINT
SEALANT ON BOTH SIDES
COPE GWB INTO FLUTES OF
DECKING AND AROUND BEAMS,
BRIDGING, PIPING, ETC...
ATTACH DEFLECTION
TRACK TO STRUCTURE
AT 24" O.C. AND WITHIN
1" OF END.
HEAD CONDITION
PARALLEL TO DECK
GWB PER
PARTITION TYPE
CONTINUOUS ACOUSTICAL
JOINT SEALANT BOTH SIDES
PROVIDE "Z"-CLIP
AS REQUIRED FOR
DEFLECTION TRACK
ATTACHMENT
MINERAL WOOL INSULATION
ABOVE DEFLECTION TRACK IN
METAL DECK FLUTES
MINERAL WOOL INSULATION
ABOVE DEFLECTION TRACK IN
METAL DECK FLUTES
ATTACH DEFLECTION
TRACK TO GWB AT 24"
O.C. AND WITHIN 1" OF
END.
HEAD CONDITION @ GWB
UNDER ROOF TRUSSES
GWB PER
PARTITION TYPE
CONTINUOUS ACOUSTICAL JOINT
SEALANT ON BOTH SIDES, TYP.
5/8" GYP CONTINUOUS ON
CFM FRAMING AT
UNDERSIDE OF PITCHED
ROOF TRUSSES, TYP.
FIRESTOP SEALANT ON BOTH
SIDES AT SMOKE PARTITIONS
(UL HW-D-0103)
/4
M
A X
FIRESTOP SEALANT ON BOTH
SIDES AT SMOKE PARTITIONS
(UL HW-D-0103)
/4
M
A X
FIRESTOP SEALANT ON BOTH
SIDES AT SMOKE PARTITIONS
(UL HW-D-0103)
/4
M
A X
COPE GWB INTO FLUTES OF
DECKING AND AROUND BEAMS,
BRIDGING, PIPING, ETC...
STRUCTURAL
FRAMING,
SEE STRUCTURAL
DWGS.
SCHEDULED
CEILING
5/8" GWB ON
3 5/8" MTL. STUDS
@ 16"O.C., TYP.
3 1/2" BATT INSULATION
FOR SOUND
ATTENUATION, TYP. UP TO
B.O. DECK, ABOVE
OPERABLE
PARTITION
2-LAYERS GWB,
PAINTED, TYP. B.S.
METAL CORNER
BEAD, TYP. B.S.
BRACKET
5 1/2"
UNISTRUT SYSTEM
0.38" DIA. HANGER RODS BY
PARTITION MANUFACTURER
HANGER BRACKET
BY MANUFACTURER
SOUND BAFFEL
#30 TRACK PRE-PAINTED
GUIDE RAIL
CEILING AS
SCHEDULED (SEE
CEILING PLANS FOR
LOCATION AND
HEIGHTS)
SCHLUTER (OR
EQUAL) ALUMINUM
COVE TRIM
BASE CONDITION
PLAN CONDITION
NEW PARTITION AS
SCHEDULED
5/8" CEMENTITIOUS
BACKER UNIT
NEW TILE FINISH,
REFER TO FINISH
SCHEDULE
CENTER OUTLETS IN TILE. COVER
ALL SIDES OF ALL TEL. & ELEC.
OUTLETS WITH 1/4" THICK
ACOUSTICAL SEALANT BEFORE
APPLYING GWB. DO NOT INSTALL
OUTLETS BACK TO BACK. TO
MAINTAIN MAX. SPACING
BETWEEN OUTLETS ON OPP.
SIDES OF PARTITIONS.
HEAD CONDITION
NOTE: MINIMUM SOUND TRANSMISSION CLASS RATING OF STC-49
ATTACH RUNNERS TO
FLOOR @ 24" O.C. AND
WITHIN 1" OF ENDS.
CONTINUOUS ACOUSTICAL
SEALANT
SCHEDULED FLOOR
SCHEDULED BASE
BASE CONDITION
PLAN CONDITION
ONE LAYER OF 5/8" TYPE "X"
GWB. W/ 1/16" LEAD LINING TO
7'-0" AFF ON IMAGING ROOM
SIDE OF METAL STUD @ 16"
O.C. VERIFY SHIELDING
REQUIREMENTS WITH
PHYSICIST REPORT
6" MINERAL WOOL
INSULATION FRICTION FIT
FOR SOUND DEADENING
LEAD LINING ON ALL
SIDES OF CUT OUTS AND
PENETRATIONS AS
REQUIRED TO MAINTAIN
CONTINUOUS
PROTECTION
HEAD CONDITION
CEILING AS SCHEDULED
2" WIDE LEAD STRIPS AT GWB
JOINTS, SAME THICKNESS AS
LEAD LINING. SHIM
INTERMEDIATE STUDS AS
NEEDED
5/8" TYPE 'X' GWB
AE601
B5
WALL TYPE STUD SIZE
METAL STUD WALL STUD SIZE SCHEDULE
M6B 6"
M4B 3 5/8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/2
/2
:4
:2
P
M
AE601
PARTITION TYPES & DETAILS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB BRS
100% CONSTRUCTION
DOCUMENTS
3" = 1'-0"
F8 METAL STUD PARTITIONS - SOUND
3" = 1'-0"
D8 METAL STUD CHASES
3" = 1'-0"
B5 TYPICAL METAL STUD HEAD CONDITION
1 1/2" = 1'-0"
F1 OPERABLE PARTITION TRACK SOFFIT
3" = 1'-0"
F5 TOILET ROOM WALLS W/ PORCELAIN TILE
3" = 1'-0"
D5 METAL STUD LEAD LINED PARTITION
B
5/8"6"5/8"2 1/2"3/4"3 5/8"
11"
3 5/8" MASONRY VENEER
CONT. 2 1/2" RIGID INSULATION
CONTINUOUS SELF
ADHERED AVB
5/8" OSB SHEATHING
6" MTL STUD W/ FOAMED
IN PLACE INSULATION, 1"
MIN.
5/8" TYPE X GWB ON 6"
METAL STUDS
MASONRY ANCHOR
B
2 1/2" FIBERGLASS "Z" FURRING
FIBER CEMENT SIDING, TYP.
1X4 VERTICAL WOOD
BLOCKING AT 24" O.C.
CONT. 2 1/2" RIGID INSULATION
CONT. SELF ADHERED AVB
5/8" OSB SHEATHING
6" MTL STUD W/ FOAMED IN
PLACE INSULATION, 1" MIN.
5/8" GWB
3/4" 2 1/2" 5/8" 6"
11"
F.9
WALL BRACKET
VERTICAL PROFILE
TRESPA WALL PANEL
WALL BRACKET AND
ANCHOR
CONT. 3" RIGID INSULATION
CONT. SELF ADHERED AVB
5/8" OSB SHEATHING
6" MTL STUD W/ FOAMED IN
PLACE INSULATION, 1" MIN.
5/8" GWB
81/256" 1 39/128" 2 1/2" 5/8" 6" 5/8"
11"
B
2 1/2" FIBERGLASS "Z" FURRING
FIBER CEMENT SIDING, TYP.
1X4 VERTICAL WOOD
BLOCKING AT 24" O.C.
CONT. 2 1/2" RIGID INSULATION
CONT. SELF ADHERED AVB
5/8" OSB SHEATHING
6" MTL STUD W/ FOAMED IN
PLACE INSULATION, 1" MIN.
5/8" GWB
11"
5/8"6"5/8"2 1/2"3/4"3/4"
B
2 1/2" FIBERGLASS "Z" FURRING
FIBER CEMENT SIDING, TYP.
1X4 VERTICAL WOOD
BLOCKING AT 24" O.C.
CONT. 2 1/2" RIGID INSULATION
CONT. SELF ADHERED AVB
5/8" OSB SHEATHING
6" MTL STUD W/ FOAMED IN
PLACE INSULATION, 1" MIN.
5/8" GWB
3/4" 2 1/2" 5/8" 6" 9 GAUGE 5/8"
11"
E9 GAUGE, 3/4" DIAMOND,
EXPANDED METAL MESH
ATTACHED TO THE INSIDE
FACE OF THE EXTERIOR
WALL STUDS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/3
/2
:4
:3
P M
AE602
EXTERIOR WALL TYPES & DETAILS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB BRS
100% CONSTRUCTION
DOCUMENTS
3" = 1'-0"
F8 EXTERIOR WALL TYPE E1 - MASONRY ON 6" MTL
STUD
3" = 1'-0"
D8 EXTERIOR WALL TYPE E2 - CLAPBOARD SIDING ON
6" MTL. STUD
3" = 1'-0"
F5 EXTERIOR WALL TYPE E3 - WOOD LOOK TRESPA
3" = 1'-0"
D5 EXTERIOR WALL TYPE E4 - WOOD SHAKE ON 6"
MTL. STUD
NOTE: R-20.5 MIN. AVERAGE WALL
INSULATION (R-13 + R-7.5 CONTINUOUS)
NOTE: R-20.5 MIN. AVERAGE WALL
INSULATION (R-13 + R-7.5 CONTINUOUS)
NOTE: R-20.5 MIN. AVERAGE WALL
INSULATION (R-13 + R-7.5 CONTINUOUS)
NOTE: R-20.5 MIN. AVERAGE WALL
INSULATION (R-13 + R-7.5 CONTINUOUS)
3" = 1'-0"
B8 EXTERIOR WALL TYPE E5 - CLAPBOARD SIDING ON
6" MTL. STUD W/ DIAMOND MTL MESH
STANDING SEAM ROOFING
SELF-ADHERED
UNDERLAYMENT
3/4" PLYWOOD
(2) LAYERS OF CONT. 3" RIGID
INSULATION, STAGGERED JOINTS
CONTINUOUS VAPOR BARRIER
1/2" COVERBOARD
METAL DECK, SEE
STRUCTURAL DRAWINGS
CFM TRUSSES,
DELEGATED DESIGN
SEE STRUCTURAL
DRAWINGS
TPO ROOFING
1/2" COVERBOARD
REQUIRED TAPERED
INSULATION OVER MIN. (2)
LAYERS 3" RIGID INSULATION
CONTINUOUS VAPOR BARRIER
1/2" PLYWOOD
METAL DECK, SEE
STRUCTURAL DRAWINGS
STEEL FRAMING, SEE
STRUCTURAL DRAWINGS
8'
0"
M
IN
. O
VER
LA
P
3"
LAYER 1
LAYER 2
RIGID INSULATION
MECHANICALLY FASTENED
TO METAL DECK
SELF ADHERING
VAPOR RETARDER
NOTES:
1. STAGGER SEAMS OF
INSULATION SHEETS SO
THAT THE CENTER OF
INSULATION SHEETS ON
LAYER 2 ARE IN LINE
WITH SEAMS OF LAYER 1
INSULATION SHEETS.
2. BUTT ALL INSULATION
TIGHT AGAINST
ADJACENT INSULATION
AND OR WOOD
BLOCKING.
NOTES:
1. REMOVE ALL LEAD AND OTHER FLASHING.
2. PRE-MOLDED PIPE SEAL MUST HAVE INTACT RIB AT TOP EDGE, REGARDLESS OF PIPE
DIAMETER.
3. APPLY IN-SEAM SEALANT 1/2" (A3 MM) FROM INSIDE EDGE OF PIPE SEAL FLANGE.
4. DECK FLANGES OF THE PRE-MOLDED PIPE FLASHING SHALL NOT BE OVERLAPPED, CUT
OR APPLIED OVER ANY ANGLE CHANGE.
LAP SPLICE
IN-SEAM SEALANT
(NOTE 3)
RIGID INSULATION
TPO MEMBRANE
PRE-MOLDED PIPE SEAL
WATER CUT-OFF MASTIC
1/2" TO 6 1/2"
NOTE 2
STAINLESS
STEEL
CLAMPING RING
SPLICING CEMENT
CONTINUOUS ROOF
UNDERLAYMENT TO
LAP OVER AVB ON
SHEATHING
METAL AND FOAM
CLOSURE SET
IN SEALANT.
STANDING SEAM METAL
ROOF W/ END CLOSURE
RIDGE CAP
TAPE AND SEALANT AT
FASTENERS PER
MANUFACTURER, TYP.
METAL ROOF DECK
SEE STRUCTURAL DRAWINGS
(2) LAYERS 3" RIGID INSULATION
(STAGGERED JOINTS) ON CONTINUOUS
VAPOR BARRIER
" M
IN
6" MIN
MINIMIZE
ROOFING FELT ON
MEMBRANE
FLASHING ON
APA WOOD
SHEATHING
COUNTER FLASH
CURB FLASHING IS
FABRICATED WITH 1"
STIFFENING LEG
CURB FLASH IS TO BE
INDEPENDENT FROM STRUCTURAL
CURB. CURB IS POSITIVELY
FASTENED TO PANELS,
THEREFORE CURB WILL EXPAND
AND CONTRACT WITH PANELS
FIELD CUT PANELS TO SUIT
CURB & RIVET TOGETHER WITH
CONT. SEALANT ON EACH SIDE
OF RIVETS. RIVETS @ 4" O.C.
MAX.
M
IN
M
IN
1"
1'-0"
4 3/8"
COUNTER FLASHING
COUNTER FLASHING FASTEN TO
MECH. CURB
CURB FLASHING IS TO BE INSTALLED
WITH A 1" CLEARANCE BETWEEN
FLASH & MECH. CURB
HEADWALL FLASHING WITH CLOSURE
SYSTEM USED AT HEAD OF CURB
RIVET PANEL TO CURB @ 4" 0.C. MAX.
WITH A CONTINUOUS BEAD OF
SEALANT ON EACH SIDE OF RIVETS.
AT STIFFENING BEADS SEAL WITH
FOAM ROD AND SEALANT
RIB CLOSURE
SLIDING HOOK CLIP TO
BE INSTALLED AT LEAST
1" FROM END OF CURB
CURB FLASHING IS
DESIGNED TO FLOAT
WITH EXPANSION AND
CONTRACTION OF THE
PANELS. A WEATHER-TIGHT
SEAL IS CRITICAL BETWEEN
BASE FLASHING &
UNDERSIDE OF PANELS
ROOFING FELT ON MEMBRANE
FLASHING ON APA WOOD
SHEATHING
" M
IN
" M
IN
2'-0"
41/4
9"
FORMED CRICKET
PANEL END CLOSURE
COUNTER FLASHING
COUNTER FLASHING FASTEN
TO MECH. CURB
RIVET PANEL TO CURB @ 4" O.C.
MAX. WITH A CONTINUOUS BEAD
OF SEALANT ON EACH SIDE OF
RIVETS. AT STIFFENING BEADS
SEAL WITH FOAM ROD & SEALANT
CURB FLASHING IS TO BE
INSTALLED WITH A 1" CLEARANCE
BETWEEN FLASHING AND
MECHANICAL CURB.
ROOFING FELT ON
MEMBRANE FLASHING
ON APA WOOD SHEATHING
JOGGLE CLEAT
VALLEY TRIM
MOVABLE CLIP
STANDING SEAM METAL
ROOF W/ END CLOSURE
W/ END CLOSURE
CONTINUOUS ROOF
UNDERLAYMENT
TO LAP OVER AVB
STANDING SEAM METAL
ROOF W/ END CLOSURE
METAL ROOF DECK
SEE STRUCTURAL DRAWINGS
STEEL ROOF JOISTS
SEE STRUCTURAL
DRAWINGS
(2) LAYERS 3" RIGID INSULATION
(STAGGERED JOINTS) ON CONTINUOUS
VAPOR BARRIER
4" MIN. TO 6" MAX.
12" MAX. HOLE IN
DECK
ROOF DRAIN
24" ROOF SUMP
RECEPTOR
TAPERED INSULATION
RIGID INSULATION
METAL DECK
16 GA. REINFORCING PLATE
PER STRUCTURAL DETAILS
Z100-C UNDERLOCK
CLAMP
IN-SEAM SEALANT
SPLICING CEMENT
LAP SEALANT
CLAMPING RING
WATER CUT-OFF
MASTIC
FASTENING PLATES @ MAX. 12" O.C.
FULLY ADHERED ROOF
MEMBRANE
FULLY ADHERED
ROOF MEMBRANE
PIPE INSULATION
M
IN
MIN.
6 1/128"
MIN.
* 3"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
WBRCINC.COM
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t
C lin ic /4
V A
C B
O C
C A
P E
C O
D
A R
C H
R
.r v t
/3
/2
:4
:3
P M
AE603
TYPICAL ROOF DETAILS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2022 JRB BRS
100% CONSTRUCTION
DOCUMENTS
3" = 1'-0"
F8 ROOF TYPE R1 - STANDING SEAM ON METAL DECK
3" = 1'-0"
C8 ROOF TYPE R2 - TPO ON METAL DECK
NOTE: R-30 MIN. AVERAGE CONTINUOUS ROOF INSULATION
NOTE: R-30 MIN. AVERAGE CONTINUOUS ROOF INSULATION
1/2" = 1'-0"
B5 STAGGERED ROOF INSULATION DETAIL
3" = 1'-0"
B3 PRE-MOLDED VENT PIPE FLASHING
3" = 1'-0"
D5 NON-VENTING HIP CAP - METAL ROOF
3" = 1'-0"
D1 CURB DETAIL 3 - METAL ROOF
3" = 1'-0"
D3 CURB DETAIL 2 - METAL ROOF
3" = 1'-0"
F2 CURB DETAIL - METAL ROOF
3" = 1'-0"
F5 TYPICAL STANDING SEAM VALLEY
3" = 1'-0"
C5 TYPICAL ROOF DRAIN DETAIL
File details come from the government source that posted it. Updated .