This document appears to be a set of technology plans and drawings for a federal contract opportunity to construct a replacement outpatient clinic at the US Coast Guard Air Station. The plans and drawings cover various technology systems, including:
The site plan shows the locations of exterior security cameras, emergency phones, and equipment enclosures. The floor plans depict the layout of PA/AV, data/nurse call, access control, CCTV, and intrusion detection systems within the clinic. Technical details are provided for cable pathways, grounding, and security door hardware. Riser diagrams illustrate the interconnections of the CATV, fiber optic, PA, access control, and CCTV/intrusion systems. The plans also include equipment rack elevations and patch panel port counts for the communications room. Overall, this document provides comprehensive technology design information to support the construction of the replacement outpatient clinic.
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
37-PIN CONNECTOR FOR PATIENT BED CONTROLS (NURSE CALL/CODE
BLUE/TV/LIGHTS/PHONE
TELECOMMUNICATIONS ABBREVIATIONS
N
TELEPHONE BACKBOARD (WALL MOUNTED)
TELEPHONE TERMINAL CABINET
DEVICE MOUNTING LOCATION AND HEIGHT NOTES:
1. FOR WHEELCHAIR PATIENT USE MOUNT TELEPHONE OUTLET 36" AFF TO
BOTTOM OF OUTLET BOX.
2. DESK PHONES - MOUNT OUTLET 1'-6" AFF.
3. PAY PHONES - MOUNT OUTLET 4'-0" AFF
4. HEIGHT OF TELECART OUTLETS SHALL BE AS INDICATED ON BEDWALLS OR
PBPU DETAILS.
5. SEE VA BARRIER FREE DESIGN GUIDE PG-18-13.
NURSE CALL STATION DOME LIGHT:
2 = NURSE'S CALL DOME LIGHT (SUFFIX INDICATES No OF LAMP) MTD 6" ABOVE
DOOR.
D = CORRIDOR DOME LIGHT WITH SOUNDER.
Z = AUXILIARY ZONE DOME LIGHT.
NURSE CALL STATION:
2 = DUPLICATE FACILITIES FOR TWO BEDS (SEPARATE INDICATORS AT
MASTER STATION) MTD 5'-0" AFF UNLESS OTHERWISE NOTED
D = DUTY STATION. MTD 5'-0" AFF UNLESS NOTED NOTED.
E = (2) PUSH BUTTON LOCATIONS VERTICALLY MTD 4'-0" AFF & 1'-8" AFF FOR
TOILET LOCATION. MAX 24" DISTNCE FROM TOILET.
P = EMERGENCY CALL PUSH BUTTON, MTD AT 3'-6" AFF.
S = AUDIO VISUAL MALL STATION (STAFF) MTD 5'-0" AFF UNLESS OTHERWISE
NOTED.
U = UTILITY CALL STATION, MTD 5'-0" AFF UNLESS OTHERWISE NOTED.
NURSE CALL TERMINAL CABINET.
NURSE'S CALL MASTER STATION MTD ON NURSE'S COUNTER TOP,
UNLESS OTHERWISE NOTED.
OUTLET; LETTER INDICATES AS FOLLOWS:
A = AUDIO
V = VIDEO - (1) SERIES-6 COAXIAL CABLE FROM CATV EQUIPMENT AND (2) CAT6A
DATA OUTLETS FROM NETWORK EQUIPMENT.
OUTLET DATA ONLY - (1) CAT6A CABLE PER PORT.
# = NUMBER OF PORTS, CH = COUNTER HEIGHT
OUTLET (VOIP) TELEPHONE, (1) PORT; (1) CAT6A CABLE. LETTER
INDICATES AS FOLLOWS:
J = JACK TYPE 18" AFF W = WALL TYPE 48" AFF
FLOOR RECEPTACLE, (VOIP) TELEPHONE
FIBEROPTICS LINE = FO
WORK AREA TCO, COMBINATION TELEPHONE/DATA COMMUNICATION OUTLET -
3 DATA PORT FACE PLATE WITH 3 DATA PORTS - (1) CAT6A CABLE PER PORT.
NCS
NCT
TTB
V
J
N
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR ARMORED CABLE
ACC ACCESSIBLE
ADDL ADDITIONAL
ADJ ADJACENT, ADJOINING
ADO AUTOMATIC DOOR OPENER
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
ALT ALTERNATE
AMB OR A AMBIENT
ARCH ARCHITECT
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
BAT BATTERY
BC BARE COPPER
BD BOARD
BFF BELOW FINISH FLOOR
BLDG BUILDING
BPIP BOILER PLANT INSTRUMENTATION PANEL
BYP BY PASS
C CONDUIT
CAB CABINET
CALC CALCULATE
CAP CAPACITY
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
CD CONSTRUCTION DOCUMENTS
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CLG CEILING
CMU CONCRETE MASONRY UNIT
COAX COAX CABLE
COMM COMMUNICATION
COMPT COMPARTMENT
CONC CONCRETE
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CTV CABLE TELEVISION
CU COPPER
CU FT CUBIC FEET
CUR CURRENT
OC ON CENTER
OD OUTSIDE DIAMETER
P POLE
PA PUBLIC ADDRESS
PB PANELBOARD, PULL BOX, OR PUSHBUTTON
PBPU PREFABRICATED BEDSIDE PATIENT UNIT
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PNL PANEL
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
RCP REFLECTED CEILING PLAN
REC RECESSED
RECPT RECEPTACLE
RGS RIGID GALVANIZED STEEL
RM ROOM
REQD REQUIRED
SF SQUARE FOOT (FEET)
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SPEC SPECIFICATION
SURF SURFACE
SW SWITCH
TEL TELEPHONE
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TYP TYPICAL
TMGB TELECOMMUNICATIONS MAIN GROUND BUSBAR
TGB TELECOMMUNICATIONS GROUND BUSBAR
MSB MAIN SWITCH BOARD
TBB TELECOMMUNICATIONS BONDING BACKBONE
UFD UNDERFLOOR DUCT
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
V VOLT
WP WEATHERPROOF
FO
COMMUNICATION SYMBOLS
SYMBOL DESCRIPTION
DB DECIBEL OR DIRECT BURIAL
DC DIRECT CURRENT
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLITION
DIAG DIAGRAM
DISTR DISTRIBUTION
DN DOWN
DRSW DOOR SWITCH
DWG DRAWING
EC EMPTY CONDUIT
EG EQUIPMENT GROUND
EL ELEVATION
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
ESMT EASEMENT
EXIST EXISTING
FLEX FLEXIBLE METALLIC CONDUIT
FOUTT TELEPHONE FLOOR OUTLET
FP FIRE PROTECTION
FT FEET OR FOOT
G OR GND GROUND OR GENERATOR
GEN GENERATOR
GTB GROUND TERMINAL BOX
HT HEIGHT
HZ HERTZ
IMC INTERMEDIATE METAL CONDUIT
IR INFRARED
J-BOX JUNCTION BOX
LF LINEAR FEET (FOOT)
LTNG LIGHTNING
LV LOW VOLTAGE
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MECH MECHANICAL
MH MANHOLE
MIN MINIMUM
MT MOUNT
MTD MOUNTED
MTG MOUNTING
NA NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
NEUT OR N NEUTRAL
NIC NOT IN CONTRACT
NS NO SCALE
NTS NOT TO SCALE
CH = COUNTER HEIGHT - COORDINATE WITH ARCHITECTURAL ELEVATIONS,
# = NUMBER OUT DATA PORTS
CH
GENERAL NOTES
1. PRODUCTS SHALL BE OF MATERIALS THAT ARE SUITABLE FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED.
2. WORKING CLEARANCES AROUND ELECTRICAL EQUIPMENT SHALL BE MAINTAINED IN COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE ARTICLE 110, COORDINATE EQUIPMENT INSTALLATION TO MAINTAIN REQUIRED CLEARANCES.
3. IF AN OUTLET BOX IS REQUIRED TO BE LOCATED IN AN ASSEMBLY OR PARTITION RATED AS "FIRE/SMOKE" OR "SMOKE" OR IDENTIFIED AS EITHER "FIRE/SMOKE" OR "SMOKE", THEN ALL OF THE FOLLOWING CONDITIONS SHALL BE MET:
THE OUTLET BOX OPENINGS SHALL OCCUR ONLY ON ONE SIDE OF THE FRAMING SPACE.
THE OUTLET BOX SHALL BE METALLIC.
THE OUTLET BOX OPENINGS SHALL NOT EXCEED 16 SQUARE INCHES.
ALL CLEARANCES BETWEEN THE OUTLET BOX AND THE WALL BOARD MATERIAL SHALL BE COMPLETELY SEALED WITH APPROVED MATERIALS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS FOR THE PROJECT.
PROVIDE A SUPPLEMENTAL BARRIER AROUND OUTLETS LARGER THAN 16 INCHES SO THAT THE ORIGINAL RATING OF
THE PENETRATION IS MAINTAINED.
THE TOTAL AGGREGATE SURFACE AREA OF THE OUTLET BOX SHALL NOT EXCEED 100 SQUARE INCHES PER 100
SQUARE FEET.
THE OUTLET BOX SHALL BE SEPARATED FROM OPENINGS ON THE OPPOSITE SIDE OF THE RATED PARTITION BY
A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES.
THE OUTLET BOX SHALL BE SECURELY FASTENED TO A PARTITION FRAMING MEMBER BY MEANS OF AN APPROVED
ATTACHMENT METHOD.
OPENINGS CUT INTO THE WALL BOARD MATERIAL SHALL NOT EXCEED 1/8 INCH BETWEEN THE EDGES OF THE OUTLET
BOX AND THE EDGES OF THE OPENING.
A.
B.
C.
D.
E.
F.
G.
H.
I.
LOCATIONS OF EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE, COORDINATE EXACT EQUIPMENT LOCATION AND
CONNECTION REQUIREMENTS WITH THE APPROPRIATE TRADE PRIOR TO INSTALLATION.
FOR EXACT LOCATION OF CEILING MOUNTED EQUIPMENT REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN. LOCATIONS OF EQUIPMENT NOT INCLUDED ON THE REFLECTED CEILING PLAN SHALL BE COORDINATED WITH THOSE ITEMS SHOWN. COORDINATION OF CEILING MOUNTED EQUIPMENT SHALL BE PRIOR TO ANY ROUGH-IN. NOTIFY ARCHITECT OF ANY DISCREPANCY.
PROVIDE FINAL CONNECTIONS TO OWNER PROVIDED EQUIPMENT WHERE INDICATED ON THE PLAN DRAWINGS.
PRIOR TO ROUGH-IN AND INSTALLATION OF ANY FLOOR MOUNTED DEVICE, VERIFY LOCATION WITH THE ARCHITECT.
VERIFY AND COORDINATE THE LOCATION OF REQUIRED DIVISION 27 OUTLETS WITH OTHER TRADE DRAWINGS AND OWNER
PROVIDED EQUIPMENT.
ALL RACEWAY SYSTEMS SHOWN TO SUPPORT THE INSTALLATION OF THE DIVISION 27 EQUIPMENT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. PROVIDE COORDINATION FOR THE INSTALLATION OF THIS RACEWAY SYSTEM WITH THE ELECTRICAL
CONTRACTOR.
4.
5.
6.
7.
8.
9.
10. EACH VOICE/DATA OUTLET LOCATION SHOWN, SHALL HAVE A DOUBLE GANG OUTLET BOX WITH A SINGLE GANG PLASTER RING AND (1) 1-1/2" CONDUIT STUBBED UP TO AN ACCESSIBLE LOCATION ABOVE THE FINISHED CEILING OR TO AN ACCESSIBLE CABLE TRAY WHERE
PROVIDED. WORK BY ELECTRICAL CONTRACTOR PER SPECS.
11.
12.
ALL BONDING AND GROUNDING ELEMENTS UTILIZED FOR STRUCTURED CABLING SYSTEM SHALL BE IN COMPLIANCE WITH SPECIFICATION
SECTION 262000.
13.
PROVIDE ALL SLEEVES AS REQUIRED FOR ALL LOW VOLTAGE CABLE PATHWAYS. RESTORE THE FIRE RATING OF THE SURFACE.
14.
CABLE UNDER SLAB USE INDOOR/OUTDOOR JACKET.
15.
TELECOMMUNICATIONS ROOM SHALL BE BONDED AND GROUNDED IN ACCORDANCE WITH TIA-607B.
PULL SCHEDULE REQUIREMENTS
CONTRACTOR SHALL PROVIDE PULL SCHEDULE WITH TELECOM SHOP DRAWINGS. TELECOM SHOP DRAWINGS WILL NOT BE REVIEWED
UNLESS THEY INCLUDE PULL SCHEDULES.
CAT 6A COPPER CABLE COLOR CODING
WHITE
YELLOW
GREEN
VIOLET
BLUE
RED
BLACK
- VOICE
- PC/PRINTER
- MULTIPLE MAC
- VIDEO SURVEILLANCE
- LAPTOP
- FIRE ALARM
- BAS & DAS
ALL TELECOMMUNICATIONS CONDUITS SHALL BE PROVIDED WITH BUSHINGS AT EACH END FOR PROTECTION OF STRUCTURED
CABLE.
STRUCTURED CABLING SYSTEM (SCS):
THE SCS CONTRACTOR (SCSC) SHALL PROVIDE ALL BACKBONE AND HORIZONTAL CABLING,
COMPONENTS AND TERMINATIONS AS REQUIRED FOR A COMPLETE AND OPERATIONAL CABLING
SYSTEM PER INDUSTRY BEST PRACTICES AS PRESCRIBED BY BICSI AND NEC.
THE SCSC SHALL BE RESPONSIBLE FOR COORDINATION WITH THE ELECTRICAL CONTRACTOR (EC) FOR SPECIFIC LOCATIONS OF ALL TELECOMMUNICATIONS SYSTEM DEVICES, INCLUDING ANCILLARY
SYSTEM COMPONENTS AND ASSOCIATED CONDUITS PROVIDED BY THE EC.
THE ELECTRICAL CONTRACTOR (EC) SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL
ROUGH-IN COMPONENTS ASSOCIATED WITH THE TELECOMMUNICATIONS SYSTEM COMPONENTS
AS NOTED ON THE DRAWINGS AND SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO, CONDUIT AND BACK-BOXES. THE EC SHALL COORDINATE ALL REQUIREMENTS WITH THE SCS CONTRACTOR.
TELECOM ROOM (TR) EQUIPMENT RACKS:
THE SCS CONTRACTOR (SCS) SHALL FURNISH AND INSTALL ALL EQUIPMENT RACKS. THE SCS
CONTRACTOR SHALL FURNISH AND INSTALL ALL CABLING PATCH PANELS (COPPER AND FIBER)
WITH RACK, AND SHALL BE RESPONSIBLE FOR ALL CABLE TERMINATIONS AT THE PATCH PANELS.
THE VA SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ALL ACTIVE EQUIPMENT,
CONTROLLERS, SWITCHES, ETC. THAT RESIDE WITHIN THESE RACKS.
ACCESS CONTROL:
THE SCS CONTRACTOR (SCS) SHALL BE RESPONSIBLE FOR INSTALLING ALL CABLING AND DEVICES TO SUPPORT THE VA PROVIDED SECURITY HEAD END EQUIPMENT. VA SHALL INSTALL, CONNECT
AND CONFIGURE FINAL SECURITY HEAD END EQUIPMENT.
THE ELECTRICAL CONTRACTOR (EC) SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL
ROUGH-IN COMPONENTS ASSOCIATED WITH THE SECURITY SYSTEM AS NOTED ON THE DRAWINGS
AND SPECIFICATIONS, INCLUDING BUT NOT LIMITED TO, CONDUIT AND BACK-BOXES. THE EC SHALL
COORDINATE WITH THE SCS CONTRACTORS.
GROUNDING AND BONDING:
THE EC SHALL BE RESPONSIBLE FOR INSTALLING THE GROUNDING BUSBAR(S) AS ILLUSTRATED ON THE DRAWINGS AND SPECIFICATIONS, AND CONNECTING IT TO THE BUILDING MAIN ELECTRICAL
SERVICE GROUND. THE EC SHALL BE RESPONSIBLE FOR GROUNDING ALL BACKBONE CONDUIT
AND CABLE TRAY.
THE SCSC SHALL BE RESPONSIBLE FOR GROUNDING ALL RACKS, CABINETS, ENCLOSURES,
PROTECTOR BLOCKS AND CABLE LADDER-RACK INSIDE TELECOMMUNICATIONS ROOMS.
FIRESTOPPING:
THE EC SHALL BE RESPONSIBLE FOR FIRE-STOPPING SLEEVE ASSEMBLIES TO OBTAIN A UL RATING.
THE SCSC SHALL BE RESPONSIBLE FOR FIRE-STOPPING INSIDE THE SLEEVES AFTER CABLE
INSTALLATION IS COMPLETE.
CASEWORK / MILLWORK:
THE SCSC SHALL BE RESPONSIBLE FOR INSTALLING TELECOMMUNICATIONS OUTLETS IN CASEWORK, AS REQUIRED. CABLES SHALL BE CONCEALED IN CASEWORK.
THE EC SHALL BE RESPONSIBLE FOR INSTALLING ASSOCIATED CONDUIT AND BACK-BOXES AND
SHALL STUB CONDUIT TO THE ABOVE ACCESSIBLE CEILING SPACE.
CONDUIT:
THE EC SHALL BE RESPONSIBLE TO PROVIDE AND INSTALL ALL BACKBONE AND HORIZONTAL CABLING
PATHWAYS. THIS SHALL INCLUDE ALL INTERIOR CONDUITS, PATHWAY COMPONENTS SUCH AS
JUNCTION BOXES, PULL BOXES, WALL/CEILING PENETRATIONS AND CONDUIT SLEEVES, WHETHER SHOWN ON THE DRAWINGS OR AS REQUIRED TO PENETRATE FULL-HEIGHT PARTITIONS AS SHOWN ON THE DRAWINGS. THE EC SHALL PROVIDE AND INSTALL ALL BUSHINGS ON TELECOMMUNICATIONS
CONDUITS PRIOR TO INSTALLATION OF CABLING.
THE SCSC SHALL BE RESPONSIBLE FOR ALL WIRE RACEWAYS, CABLE RUNWAY (LADDER RACK) AND
OTHER REQUIREMENTS FOR ROUTING AND SECURING CABLE INSIDE THE MAIN
TELECOMMUNICATIONS ROOM (MTR) AND ALL TR'S.
TELECOMMUNICATIONS COMMUNICATIONS OUTLETS (C.O.'S) AND DEVICES:
THE EC SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL CONDUIT AND BACK-BOXES
ASSOCIATED WITH THE TELECOMMUNICATIONS C.O.'S AND DEVICES.
THE SCSC SHALL BE RESPONSIBLE FOR INSTALLATION OF ALL STRUCTURED CABLING, JACKS,
FACEPLATES AND JUMPER/PATCH CORDS.
BACKBOARDS:
THE EC SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL BACKBOARDS AS ILLUSTRATED
ON THE DRAWINGS AND AS REQUIRED FOR A COMPLETE SYSTEM AS ILLUSTRATED IN THE
SPECIFICATIONS. THE EX SHALL BE RESPONSIBLE FOR ROUGH-IN OF ALL CONDUIT AND BACK-BOXES.
POWER CONDUITS SHALL BE CONCEALED BEHIND ALL BACKBOARDS. BACKBONE CONDUIT SHALL BE
EXPOSED AS ILLUSTRATED ON THE DRAWINGS (TR WALL ELEVATIONS).
COORDINATION NOTES:
SYMBOL DESCRIPTION
CEILING MOUNTED WIRELESS ACCESS POINT (WAP) - (2) CAT6A CABLES
PROXIMITY CARD READER, MTD. 4'-0" AFF UNLESS OTHERWISE
NOTED. REFER TO ARCHITECTURAL DOOR HARDWARE SCHEDULE
FOR REQUEST TO EXIT HARDWARE.
CR
FLOOR RECEPTACLE, COMBINATION TELEPHONE/DATA COMMUNICATION OUTLET -
3 DATA PORTS - (1) CAT6A CABLE PER PORT.
NUMERIC KEYPAD, MTD. 4'-0" AFF UNLESS OTHERWISE NOTED.KP
REQUEST TO EXIT DEVICE IN DOOR HARDWARE. RE
ML
SECURITY ACCESS, VIDEO CAMERA WITH LENS
ML = MULTI LENS
### MULTI LENS VIEW ANGEL
FIX = FIXED WITH MOTION DETECTOR
PZ = MOTION DETECTOR WITH PAN AND ZOOM
PTZ= MOTION DETECTOR WITH PAN, TILT, AND ZOOM
CEILING MOUNTED PUBLIC ADDRESS SYSTEM SPEAKERS
SECURITY DURESS BUTTON
D = DURESS
P = PANIC
D
FIX
CEILING MOUNTED
WALL MOUNTED
REQUEST TO EXIT DEVICE MOUNTED ABOVE DOOR.RE
GROUND BUS BAR, COPPER
INTERCOM CALL STATIONCS
ADMINISTRATIVE PHONEAP
INTERCOM/VOIP HANDSETHS
COMBINATION CARD READER/NUMERIC KEYPAD, MTD. 4'-0" AFF
UNLESS OTHERWISE NOTED.CK
4-POST NETWORK EQUIPMENT RACK.
LADDER TYPE CABLE TRAY; SIZE AND MOUNTING HEIGHT AS INDICATED ON
PLANS.
BASKET/SOLID BOTTOM/CHANNEL TYPE CABLE TRAY; SIZE, TYPE AND MOUNTING
HEIGHT AS INDICATED ON PLANS.
DOOR CONTACTDC
BIOMETRIC READER, MTD. 4'-0" AFF UNLESS OTHERWISE NOTED.BM
CEILING MOUNTED MOTION SENSOR FOR INTRUSION DETECTION SYSTEM.
CEILING MOUNTED GLASS BREAK SENSOR FOR INTRUSION DETECTION SYSTEM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
BI
M
- C on st ru ct
R ep la ce m en t O ut pa tie nt C lin ic
/0
C on st . R ep la ce . O ut pa tie nt
C lin ic
R
.rv t
2/ 8/
:1
1:
P M
T-001
TECHNOLOGY LEGEND AND
SYMBOLS
REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2023 JFR CVM
100% CONSTRUCTION
DOCUMENTS
Christopher Van Meter RCDD Reg. No. 285002
SHEET LIST
Sheet Number Sheet Name
T-001 TECHNOLOGY LEGEND AND SYMBOLS
T-101 TECHNOLOGY SITE PLAN
TA101 TECHNOLOGY PA/AV - WEST
TA102 TECHNOLOGY PA/AV - EAST
TN101 TECHNOLOGY DATA/NURSE CALL - WEST
TN102 TECHNOLOGY DATA/NURSE CALL - EAST
TS101 TECHNOLOGY ACCESS/CCTV/INTRUSION - WEST
TS102 TECHNOLOGY ACCESS/CCTV/INTRUSION - EAST
T-401 TECHNOLOGY ENLARGED PLANS
T-501 TECHNOLOGY DETAILS
T-601 TECHNOLOGY RISERS AND DIAGRAMS
Revisions Date
C
C
C
C C
C
C
C
C
C
C
C
CCCCC
C C C C CC
C C
CCCCCCC
C C
C C
CCC
UE
U E
GAS
LINE POST
APPROX. GAS
MAIN
APPROX. GAS
MAIN
UP #9 UP #601/7
ML
ML
M L
ML
ML
ML
ML ML MLMLML
ML ML
ML ML ML ML ML ML
270270
270 270
P
P
P
CONNERY AVENUE
11 3 11
5 7
5 7
12 7
27011
CONDUIT UP 8' ON UTILITY POLE AND
PROVIDE METAL GUARD TO ATTACHMENT
POINT FROM UTILITY
EXISTING
UTILITY POLE
3 3
270270
270 270
270 270 270 270 270 270
5 7 12
CONNERY AVENUE
3/4" SEAL TIGHT FLEXIBLE
NONMETALLIC RACEWAY
" A
FG
TYPICAL POLE MOUNTED
CAMERA INSTALLED PER
MANUFACTURERS
INSTALLATION
INSTRUCTIONS.
24" TALL LIGHTING
PROTECTION AIR TERMINAL
20' DRIVEN COPPER
GROUND ROD.
1/0AWG BRAIDED COPPER
DOWNLEAD TO GROUND
ROD.
NEMA 3R POLE MOUNTED
EQUIPMENT ENCLOSURE
BOND GROUND BLOCK #8 AWG CU
GROUNDING CONDUCTOR TO
DOWNLEAD.
NEMA 3R EQUIPMENT ENCLOSURE WITH
LOCKABLE COVER MIN 16"X36"X8"
MOUNTED ON POLE AT 30" ABOVE
FINISHED GRADE.
SITE LIGHTING POLE
GFCI DOUBLE
DUPLEX OUTLET
ENVIROMENTALLY
HARDENED FIBER MEDIA
CONVERTER WITH (8)
PORT POE+ OUTPUT.
1" CONDUIT FOR 120V
POWER. REFER TO
ELECTRICAL DRAWINGS
FOR ADDITIONAL
INFORMATION.
1" CONDUIT FOR
NETWORK CABLING
DIN-RAIL MOUNTING
SYSTEM, TYPICAL
GROUND BLOCK
#8 AWG CU GND TO
GROUND ROD.
CONDUITS MUST BE ROUTED
WITHIN 4" DIA OF CENTER OF
CONCRETE PEDESTAL.
ø 0' - 4"
1-1/2" CONDUIT TYPICAL
CONDUIT – ELECTRICAL AND TELEPHONE LINE CONDUIT, WITH A
MAXIMUM COMBINED DIAMETER OF FOUR INCHES, SHOULD BE
RUN UP THROUGH THE CENTER OF THE FOUNDATION HOLE. A
MINIMUM OF FOUR INCHES AND A MAXIMUM OF SIX INCHES OF
CONDUIT ABOVE THE FINISHED GRADE LEVEL IS REQRUIED TO
ENSURE PROPER GROUNDING, INSTALL 1/2" X 8' COPPER ROD IN
THE CENTER OF THE FOUNDATION AND TIE TO THE STEEL
PEDESTAL
PULL POWER AND FIBER OPTIC CABLE UP THROUGH THE
CONDUITS - A MINIMUM OF 2' OF WIRE MUST BE VAILABLE FROM
THE CONDUIT FOR ELECTRICAL AND COMMUNICATIONS WIRING.
CONCRETE FOUNDATION,
REFER TO CIVIL DRAWINGS FOR
ADDITIONAL INFORMATION.
ø 2' - 0"
FINISH GRADE
1'-7"
3"EQ
1'-0"
2'-4"
1'-2"
EQ"
4" SCHD 40 PVC CONDUIT WITH (2) 4"
3-CELL INNERDUCTS.
REINFORCED CONCRETE
ENCASEMENT (4000 PSI RATED
@ 28 DAYS)
EQ"
WARNING TAPE
WITH TRACER
CONDUIT SPACER (TYP.)
EQ
4" SCHD 40 PVC CONDUIT WITH (2) 4"
3-CELL INNERDUCTS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
BI
M
- C on st ru ct
R ep la ce m en t O ut pa tie nt C lin ic
/0
C on st . R ep la ce . O ut pa tie nt
C lin ic
R
.rv t
2/ 8/
:1
1:
P M
T-101
TECHNOLOGY SITE PLAN REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2023 JFR CVM
100% CONSTRUCTION
DOCUMENTS
Christopher Van Meter RCDD Reg. No. 285002
1/16" = 1'-0"T-101
1 SITE PLAN - TELECOM
CODED NOTES:
CONCRETE ENCASED (2) 4" CONDUITS FROM COMMUNICATIONS R00M 152 (REFER TO SHEET T-401 FOR LOCATION) FOR CONNECTION TO LOCAL UTILITIES. COORDINATE EXACT TERMINATION POINT WITH LOCAL UTILITIES PRIOR TO CONSTRUCTION. PROVIDE ALL CONDUITS WITH (2) 4", 3-CELL CLOTH INNERDUCTS. BASIS OF DESIGN IS MAXCELL MXE86383. REFER TO FIBER OPTIC DUCT BANK DETAIL
ON THIS SHEET FOR ADDITIONAL INFORMATION.
SECURITY MULTI SENSOR CAMERA MOUNTED TO SITE LIGHTING POLE. CAMERA MOUNTED AT 15'
AFG. COORDINATE EXACT LOCATION OF CAMERA WITH LIGHT POLE PRIOR TO CONSTRUCTION.
COORDINATE EXACT LOCATION OF SITE LIGHTING POLE WITH ELECTRICAL PLANS PRIOR TO
CONSTRUCTION. PROVIDE ALL MOUNTING HARDWARE REQUIRED PER MANUFACTURERS
INSTALLATION INSTRUCTIONS. CAMERA BASIS OF DESIGN IS AVIGILON 24C-H4A-3MH-270.
SECURITY MULTI SENSOR CAMERA MOUNTED TO BUILDING EXTERIOR. CAMERA MOUNTED AT 14'
AFG. COORDINATE EXACT LOCATION OF CAMERA WITH ARCHITECTURAL PLANS PRIOR TO
CONSTRUCTION. PROVIDE ALL MOUNTING HARDWARE REQUIRED PER MANUFACTURERS
INSTALLATION INSTRUCTIONS. CAMERA BASIS OF DESIGN IS AVIGILON 24C-H4A-3MH-270.
EMERGENCY PHONE STATION. COORDINATE EXACT LOCATION WITH CIVIL PLANS. INSTALL PER
MANUFACTURES INSTALLATION INSTRUCTIONS. BASIS OF DESIGN IS CODE BLUE - CB9 SERIES.
SITE CCTV CAMERA FIBER OPTIC CABLING IN 1-1/2" CONDUIT. (4) STRANDS OF INDOOR/OUTDOOR OM4
FIBER OPTIC CABLE TO EACH POLE MOUNTED EQUIPMENT ENCLOSURE. REFER TO
CCTV/EMERGENCY PHONE RISER DIAGRAM ON SHEET T-601 FOR ADDITIONAL INFORMATION.
SITE CCTV CAMERA CAT6A CABLING IN 1-1/2" CONDUIT. REFER TO CCTV/EMERGENCY PHONE RISER
DIAGRAM ON SHEET T-601 RISER DIAGRAM FOR ADDITIONAL INFORMATION.
EMERGENCY PHONE FIBER OPTIC CABLING IN 1-1/2" CONDUIT. (4) STRANDS OF INDOOR/OUTDOOR
OM4 FIBER OPTIC CABLE TO EACH EMERGENCY PHONE LOCATION. REFER TO CCTV/EMERGENCY
PHONE RISER DIAGRAM ON SHEET T-601 RISER DIAGRAM FOR ADDITIONAL INFORMATION.
12"X12"X12" PRECAST TRAFFIC RATED PULL BOX.
POLE MOUNTED EQUIPMENT ENCLOSURE ON THIS POLE. REFER TO DETAILS ON THIS SHEET FOR
ADDITIONAL INFORMATION.
COORDINATE EXACT LOCATION OF CAMERA WITH CANOPY. REFER TO ARCHITECTURAL PLANS FOR
ADDITIONAL CANOPY INFORMATION.
CAMERA TO BE LOCATED ON CORNER OF BUILDING. COORDINATE EXACT LOCATION IN FIELD AND
WITH ARCHITECTURAL DRAWINGS.
CONCRETE ENCASE CONDUITS WHEN LOCATED UNDER DRIVEWAYS.
DRAWING NOTES:
1. CONDUIT ROUTING INDICATED ON THIS PLAN IS DIAGRAMATIC. CONTRACTOR TO FIELD COORDINATE
EXACT ROUTING OF CONDUITS AND DUCT BANKS WITH ALL OTHER DISCIPLINES PRIOR TO
CONSTRUCTION. CONTRACTOR TO PROVIDE PULL BOXES AS REQUIRED TO COMPLY WITH CABLE
PULL REQUIREMENTS FOR EXACT ROUTING AND DISTANCES OF INSTALLED CONDUIT AND DUCT
BANK ROUTING.
0 8' 16' 32' 48'
1/16" = 1'-0"
N.T.S.
TYPICAL POLE MOUNTED CCTV CAMERA4
N.T.S.
TYPICAL POLE MOUNTED EQUIPMENT ENCLOSURE5
N
N.T.S.
TYPICAL EMERGENCY CALL BOX BASE DETAIL2
N.T.S.
FIBER OPTIC DUCT BANK DETAIL3
R
EF
R
EF
SSS
S
S S S
S S
S
SS
S
S
S
S
S
S
S
S
S
S
S S
S S
S S
S
SSS
S
S
S
S
S S S S
S
S
V
V
V
V
V
J
J
J
V
S
V
V
H G F E D
I
+72"
+60"
+60"
+60"
+60"
VESTIBULE
WAITING
WAITING
VOLUNTEER
RECEPTION
SPECIMEN
COLLECTION
TOILET WMN'S
EXAM RM
WOMEN'S
HEALTH
ULTRASOUND
TREATMENT
EXERCISE AREA
CORRIDOR
CORRIDOR
EXAM /
AUDIOLOGY
EXAM / EYE TEST
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
GROUP THERAPY
ROOM, MENTAL
HEALTH
MULTI-PURPOSE
ROOM
SOCIAL WORKER
TOILET PUBLIC
TOILET PUBLIC
TOILET STAFF
MED ROOM
TEAM WORK
AREA
EXAM /
TELE-HEALTH
TOILET STAFF
TOILET PROC.
PROCEDURE
ROOM, GENERAL
EXAM / TRIAGE
RECEPTION
WORKROOM
NURSE
MANAGER
EXAM /
TELE-HEALTH
EXAM/TRIAGE
EXAM / MENTAL
HEALTH
EXAM
CORRIDOR
CORRIDOR
EXAM / PT/OT
EXAM
MULTI-PURPOSE
ROOM
TOILET PATIENT
TOILET PATIENT
H.2 H.1 F.7 F.5 F.3 E.5 D.9 D.7 D.6 D.5 D.3 C.6 C.5 C.3
5.5
3.7
3.6
3.3
3.1
2.7
2.5
2.4
1.9
1.5
1.3
+60"
72"
+60"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
BI
M
- C on st ru ct
R ep la ce m en t O ut pa tie nt C lin ic
/0
C on st . R ep la ce . O ut pa tie nt
C lin ic
R
.rv t
2/ 8/
:1
2:
P M
TA101
TECHNOLOGY PA/AV - WEST REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2023 JFR CVM
100% CONSTRUCTION
DOCUMENTS
Christopher Van Meter RCDD Reg. No. 285002
CODED NOTES:
COORDINATE LOCATION OF VIDEO OUTLET BOX WITH TV MOUNT, DATA OUTLETS AND POWER
RECEPTACLE. ALL CONNECTIONS TO BE CONTAINED WITHIN RECESSED VIDEO OUTLET BOX.
PROVIDE 1-1/2" CONDUIT WITH PULL STRING FROM VIDEO OUTLET BOX TO RECESSED JUNCTION BOX
FOR VIDEO CONNECTION TO LOCAL EQUIPMENT.
DRAWING NOTES:
1. COORDINATE EXACT LOCATION OF ALL CEILING MOUNTED DEVICES WITH ARCHITECTURAL RCP AND
ALL OTHER TRADES PRIOR TO CONSTRUCTION.
0 4' 8' 12' 16'
3/16" = 1'-0"
3/16" = 1'-0"TA101
1 FIRST FLOOR PLAN - PA/AV - WEST N
REF.
S
S
S
S S
S
S
S
S
S
V
S
V V
J
C B A
COMMUNICATIONS
STORAGE
MEDICAL &
GENERAL
STAFF LOUNGE &
LOCKERS
WORKSTATIONS,
MENTAL HEALTH
OFFICE
MECHANICAL
UTILITY CLEAN
UTILITY SOILED
JANITOR CLOSET
CORRIDOR
+60"
OFFICE
B.7 A.4
5.5
3.7
3.6
3.3
3.1
2.7
2.5
2.4
1.9
1.5
1.3
+66"
+66"
ELECTRICAL
ROOM
2 2
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
BI
M
- C on st ru ct
R ep la ce m en t O ut pa tie nt C lin ic
/0
C on st . R ep la ce . O ut pa tie nt
C lin ic
R
.rv t
2/ 8/
:1
2:
P M
TA102
TECHNOLOGY PA/AV - EAST REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2023 JFR CVM
100% CONSTRUCTION
DOCUMENTS
Christopher Van Meter RCDD Reg. No. 285002
3/16" = 1'-0"TA102
1 FIRST FLOOR PLAN - PA/AV - EAST
CODED NOTES:
COORDINATE LOCATION OF VIDEO OUTLET BOX WITH TV MOUNT, DATA OUTLETS AND POWER
RECEPTACLE. ALL CONNECTIONS TO BE CONTAINED WITHIN RECESSED VIDEO OUTLET BOX.
PROVIDE 1-1/2" CONDUIT WITH PULL STRING FROM VIDEO OUTLET BOX TO RECESSED JUNCTION BOX
FOR VIDEO CONNECTION TO LOCAL EQUIPMENT.
DRAWING NOTES:
1. COORDINATE EXACT LOCATION OF ALL CEILING MOUNTED DEVICES WITH ARCHITECTURAL RCP AND
ALL OTHER TRADES PRIOR TO CONSTRUCTION.
0 4' 8' 12' 16'
3/16" = 1'-0"
N
BB
F
BB
F
BB
F
BBF
BBF
R
EF
R
EF
BBF BBF
BBF BBF
BBF BBF
BBF BBF
BBF BBF
BBF BBF
BBF BBF
BBF BBF
BBF BBF
BBF BBF
BBF BBF
BBF BBF
BBF
BBF
BBF
BBF
BB
F
BB
F
BBFBBFBBFBBFBBFBBFBBFBBFBBFBBFBBFBBFBBFBBF
BBF
N
N
N
N N
N N
N
NN
N
N
N
N N
N
NN
V
V
V
V
V
N NNN
N
N N
N N N N
N
NNN
N
N
N
N
N
V
N N
V
V
H G F E D
I
CH
2 TYPICAL OF (8)
W
NCS
D
E
E
E E
P P
P
PP
P
P
P
PP
P
PP
VESTIBULE
103 WAITING
WAITING
VOLUNTEER
RECEPTION
SPECIMEN
COLLECTION
TOILET WMN'S
EXAM RM
WOMEN'S
HEALTH
135 ULTRASOUND
TREATMENT
EXERCISE AREA
CORRIDOR
CORRIDOR
EXAM /
AUDIOLOGY
124 EXAM / EYE TEST
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
GROUP THERAPY
ROOM, MENTAL
HEALTH
MULTI-PURPOSE
ROOM
SOCIAL WORKER
TOILET PUBLIC
TOILET PUBLIC
TOILET STAFF
MED ROOM
TEAM WORK
AREA
EXAM /
TELE-HEALTH
TOILET STAFF
TOILET PROC.
PROCEDURE
ROOM, GENERAL
EXAM / TRIAGE
RECEPTION
WORKROOM
NURSE
MANAGER
EXAM /
TELE-HEALTH
EXAM/TRIAGE
EXAM / MENTAL
HEALTH
EXAM
CORRIDOR
CORRIDOR
EXAM / PT/OT
EXAM
D DDD
D
D D
D D D D
D
DDD
D
D
D
D
MULTI-PURPOSE
ROOM
TOILET PATIENT
TOILET PATIENT
6 6
6 6 6
1 TYPICAL
D
77 77 7
77 77 77 7
H.2 H.1 F.7 F.5 F.3 E.5 D.9 D.7 D.6 D.5 D.3 C.6 C.5 C.3
5.5
3.7
3.6
3.3
3.1
2.7
2.5
2.4
1.9
1.5
1.3
CH
CH
CHCHCH
CH
ALCOVE, SCALE
CH
CH
CHCHCH
CH
CH
E
E
+72"
+60"
+60"
+60"
+60"
+60"
72"
CH
W W W
W
W
W W
W
W
WW
W
W
+36"
CH
+36" +36"
+36" +36"
W
W
W
CH CH
+36"
+36"+36"
+36"
+36"
+36"
+36"
+36"
44 4
444 4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
BI
M
- C on st ru ct
R ep la ce m en t O ut pa tie nt C lin ic
/0
C on st . R ep la ce . O ut pa tie nt
C lin ic
R
.rv t
2/ 8/
:1
2:
P M
TN101
TECHNOLOGY DATA/NURSE CALL
- WEST
REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2023 JFR CVM
100% CONSTRUCTION
DOCUMENTS
Christopher Van Meter RCDD Reg. No. 285002
CODED NOTES:
COMBINATION DATA AND POWER FLOOR BOX FOR SYSTEM FURNITURE CONNECTION. REFER TO
ELECTRICAL SHEET EP101 FOR ADDITIONAL INFORMATION. COORDINATE EXACT LOCATION WITH SYSTEMS FURNITURE PRIOR TO CONSTRUCTION. PROVIDE 1" CONDUIT BELOW SLAB TO NEAREST
FULL HEIGHT WALL.
FLOOR BOX FOR SYSTEMS FURNITURE DATA CONNECTIONS. COORDINATE EXACT LOCATION WITH
SYSTEMS FURNITURE PRIOR TO CONSTRUCTION. REFER TO ELECTRICAL SHEET E-203 FOR
ADDITIONAL INFORMATION.
(4) 4" PVC CONDUIT SLEEVES THROUGH WALL. PROVIDE WITH BUSHING ON ALL ENDS. COORDINATE
EXACT HEIGHT AND LOCATION WITH CABLE TRAY PRIOR TO CONSTRUCTION.
CONDUIT ROUTED BELOW SLAB TO NEAREST FULL HEIGHT WALL.
18"X4" BASKET STYLE CABLE TRAY INSTALLED AT MINIMUM OF 4" ABOVE ACCESSIBLE CEILING TO
BOTTOM OF TRAY. MAINTAIN 12" CLEAR ABOVE CABLE TRAY FOR ANY ELEMENTS THAT RUN
PARALLEL TO THE CABLE TRAY AND MINIMUM OF 4" CLEAR FOR ANY ELEMENTS THAT CROSS
PERPENDICULAR TO CABLE TRAY. COORDINATE ROUTING OF CABLE TRAY WITH ALL OTHER
UTILITIES.
12"X4" BASKET STYLE CABLE TRAY INSTALLED AT MINIMUM OF 4" ABOVE ACCESSIBLE CEILING TO
BOTTOM OF TRAY. MAINTAIN 12" CLEAR ABOVE CABLE TRAY FOR ANY ELEMENTS THAT RUN
PARALLEL TO THE CABLE TRAY AND MINIMUM OF 4" CLEAR FOR ANY ELEMENTS THAT CROSS
PERPENDICULAR TO CABLE TRAY. COORDINATE ROUTING OF CABLE TRAY WITH ALL OTHER
UTILITIES.
DATA OUTLETS IN SYSTEMS FURNITURE. COORDINATE TERMINATION OF STRUCTURED CABLING
WITH SYSTEMS FURNITURE PRIOR TO CONSTRUCTION. REFER TO CODED NOTE 2 ABOVE FOR
ADDITIONAL INFORMATION.
DRAWING NOTES:
1. COORDINATE EXACT LOCATION OF ALL CEILING MOUNTED DEVICES WITH ARCHITECTURAL RCP AND
ALL OTHER TRADES PRIOR TO CONSTRUCTION.
2. CONTRACTOR SHALL COORDINATE EXACT ROUTING OF CONDUIT AND CABLE TRAYS IN FIELD PRIOR
TO CONSTRUCTION. CONDUIT ROUTING INDICATED ON THIS PLAN IS DIAGRAMMATIC.
3. FAX MACHINE OUTLET CABLING TERMINATES 0N 110 PUNCH DOWN BLOCKS IN COMM ROOM 152.
REFER TO SHEETS T-401 AND T-601 FOR ADDITIONAL INFORMATION. COORDINATE LOCATION OF FAX
MACHINE CONNECTIONS WITH VA PRIOR TO CONSTRUCTION.
0 4' 8' 12' 16'
3/16" = 1'-0"
3/16" = 1'-0"TN101
1 FIRST FLOOR PLAN - DATA/NURSE CALL - WEST
BBF BBF BBF BBF
BBF BBF BBF BBF
BBFBBF
BBF
BBF BBF BBF BBF
BBFBBFBBF
BB
F
BB
F
N
V
V V
J
C B A
T-401
W
W
D
COMMUNICATIONS
STORAGE
MEDICAL &
GENERAL
STAFF LOUNGE &
LOCKERS
WORKSTATIONS,
MENTAL HEALTH
OFFICE
OFFICE
MECHANICAL
UTILITY CLEAN
UTILITY SOILED
JANITOR CLOSET
CORRIDOR
ELECTRICAL
ROOM
B.7 A.4
5.5
3.7
3.6
3.3
3.1
2.7
2.5
2.4
1.9
1.5
1.3
+60"
+66" +66"
W
W
+42" +42" +42" +42"
+42"+42"+42"+42"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
BI
M
- C on st ru ct
R ep la ce m en t O ut pa tie nt C lin ic
/0
C on st . R ep la ce . O ut pa tie nt
C lin ic
R
.rv t
2/ 8/
:1
3:
P M
TN102
TECHNOLOGY DATA/NURSE CALL
- EAST
REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2023 JFR CVM
100% CONSTRUCTION
DOCUMENTS
Christopher Van Meter RCDD Reg. No. 285002
3/16" = 1'-0"TN102
1 FIRST FLOOR PLAN - DATA/NURSE CALL - EAST
CODED NOTES:
12"X4" BASKET STYLE CABLE TRAY INSTALLED AT MINIMUM OF 4" ABOVE ACCESSIBLE CEILING TO
BOTTOM OF TRAY. MAINTAIN 12" CLEAR ABOVE CABLE TRAY FOR ANY ELEMENTS THAT RUN
PARALLEL TO THE CABLE TRAY AND MINIMUM OF 4" CLEAR FOR ANY ELEMENTS THAT CROSS
PERPENDICULAR TO CABLE TRAY. COORDINATE ROUTING OF CABLE TRAY WITH ALL OTHER
UTILITIES.
18"X4" BASKET STYLE CABLE TRAY INSTALLED AT MINIMUM OF 4" ABOVE ACCESSIBLE CEILING TO
BOTTOM OF TRAY. MAINTAIN 12" CLEAR ABOVE CABLE TRAY FOR ANY ELEMENTS THAT RUN
PARALLEL TO THE CABLE TRAY AND MINIMUM OF 4" CLEAR FOR ANY ELEMENTS THAT CROSS
PERPENDICULAR TO CABLE TRAY. COORDINATE ROUTING OF CABLE TRAY WITH ALL OTHER
UTILITIES.
(4) 4" PVC CONDUIT SLEEVES THROUGH WALL. PROVIDE WITH BUSHING ON ALL ENDS. COORDINATE
EXACT HEIGHT AND LOCATION WITH CABLE TRAY PRIOR TO CONSTRUCTION.
24"X6" BASKET STYLE CABLE TRAY INSTALLED AT MINIMUM OF 4" ABOVE ACCESSIBLE CEILING TO
BOTTOM OF TRAY. MAINTAIN 12" CLEAR ABOVE CABLE TRAY FOR ANY ELEMENTS THAT RUN
PARALLEL TO THE CABLE TRAY AND MINIMUM OF 4" CLEAR FOR ANY ELEMENTS THAT CROSS
PERPENDICULAR TO CABLE TRAY. COORDINATE ROUTING OF CABLE TRAY WITH ALL OTHER
UTILITIES.
DRAWING NOTES:
1. COORDINATE EXACT LOCATION OF ALL CEILING MOUNTED DEVICES WITH ARCHITECTURAL RCP AND
ALL OTHER TRADES PRIOR TO CONSTRUCTION.
2. CONTRACTOR SHALL COORDINATE EXACT ROUTING OF CONDUIT AND CABLE TRAYS IN FIELD PRIOR
TO CONSTRUCTION. CONDUIT ROUTING INDICATED ON THIS PLAN IS DIAGRAMMATIC.
3. FAX MACHINE OUTLET CABLING TERMINATES 0N 110 PUNCH DOWN BLOCKS IN COMM ROOM 152.
REFER TO SHEETS T-401 AND T-601 FOR ADDITIONAL INFORMATION. COORDINATE LOCATION OF FAX
MACHINE CONNECTIONS WITH VA PRIOR TO CONSTRUCTION.
0 4' 8' 12' 16'
3/16" = 1'-0"
N
R
EF
R
EF
CK
CK
CK
CKFIX FIX
FIX
FIX
FI
X
FIX
FIX
FIX
FIX
CK
FIX
CK
KP
RE
RE
RE
RE
CK
CK
RE
CK
RE
CK
RE
CK
RE
RE
CK
RE
BM
RE
FI
X
FI
X
FIX
FIX
CK
RE
RE
FIX
CK
CK
RE
CK
CK
RE
RE
RE
H G F E D
I
WP
VESTIBULE
WAITING
WAITING
VOLUNTEER
RECEPTION
SPECIMEN
COLLECTION
TOILET WMN'S
EXAM RM
WOMEN'S
HEALTH
ULTRASOUND
TREATMENT
EXERCISE AREA
CORRIDOR
CORRIDOR
EXAM /
AUDIOLOGY
124 EXAM / EYE TEST
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
CONSULT RM,
MENTAL HLTH
GROUP THERAPY
ROOM, MENTAL
HEALTH
MULTI-PURPOSE
ROOM
SOCIAL WORKER
TOILET PUBLIC
TOILET PUBLIC
TOILET STAFF
MED ROOM
TEAM WORK
AREA
EXAM /
TELE-HEALTH
TOILET STAFF
TOILET PROC.
142PROCEDURE
ROOM, GENERAL
EXAM / TRIAGE
RECEPTION
WORKROOM
NURSE
MANAGER
EXAM /
TELE-HEALTH
EXAM/TRIAGE
EXAM / MENTAL
HEALTH
EXAM
CORRIDOR
CORRIDOR
EXAM / PT/OT
EXAM
MULTI-PURPOSE
ROOM
TOILET PATIENT
TOILET PATIENT
WP
FISHEYE
H.2H.1 F.7 F.5 F.3 E.5 D.9 D.7 D.6D.5 D.3 C.6 C.5 C.3
5.5
3.7
3.6
3.3
3.1
2.7
2.5
2.4
1.9
1.5
1.3
WP
4 TYPICAL5 TYPICAL
11TYPICAL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
BI
M
- C on st ru ct
R ep la ce m en t O ut pa tie nt C lin ic
/0
C on st . R ep la ce . O ut pa tie nt
C lin ic
R
.rv t
2/ 8/
:1
3:
P M
TS101
TECHNOLOGY
ACCESS/CCTV/INTRUSION - WEST
REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2023 JFR CVM
100% CONSTRUCTION
DOCUMENTS
Christopher Van Meter RCDD Reg. No. 285002
CODED NOTES:
KEYPAD FOR INTRUSION DETECTION SYSTEM.
REQUEST TO EXIT FUNCTION TIED TO ADA DOOR OPENER PUSH PLATE ON SECURE SIDE AT THIS
DOOR.
CONNECT ADA DOOR ACTUATOR TO ACCESS CONTROL SYSTEM DRY CONTACT FOR ACTUATION OF
DOOR INDICATED UPON CONFIRMATION OF ACCESS REQUEST.
CEILING MOUNTED MOTION SENSOR CONNECTED TO INTRUSION DETECTION SYSTEM. COORDINATE EXACT LOCATION OF DETECTOR WITH ALL CEILING MOUNTED DEVICES PRIOR TO CONSTRUCTION.
CEILING MOUNTED GLASS BREAK SENSOR CONNECTED TO INTRUSION DETECTION SYSTEM.
COORDINATE EXACT LOCATION OF DETECTOR WITH ALL CEILING MOUNTED DEVICES PRIOR TO
CONSTRUCTION.
CONFIGURE DOOR FOR DELAYED EGRESS WITH ALARM. COORDINATE WITH DOOR HARDWARE
SCHEDULE.
MAIN ENTRY DOOR SHALL BE CONFIGURED FOR FREE INGRESS/EGRESS DURING NORMAL BUSINESS
HOURS. ACCESS CONTROL SYSTEM WILL DE-ENERGIZE ADA OPERATOR OUTSIDE OF NORMAL
BUSINESS HOURS. CONTRACTOR SHALL PROVIDE WIRING AND PROGRAMING AS REQUIRED TO
PERFORM FUNCTION AS INDICATED. COORDINATE WITH ELECTRICAL DRAWINGS PRIOR TO
CONSTRUCTION.
ON SITE CCTV MONITORING STATION. COORDINATE EXACT LOCATION OF PC AND MONITORS WITH
ARCHITECTURAL PLANS AND FURNITURE LAYOUT PRIOR TO CONSTRUCTION.
PATH OF EGRESS DOOR. ACCESS CONTROL SYSTEM SHALL PROVIDE FREE INGRESS AND EGRESS
OF DOOR UPON ACTIVATION OF FIRE ALARM SYSTEM.
RECESSED IN CEILING FISH EYE CAMERA. LOCATED IN CENTER OF ROOM. COORDINATE EXACT
LOCATION WITH ALL OTHER CEILING MOUNTED DEVICES. CAMERA BASIS OF DESIGN IS AVIGILON
12.0W-H5A-FE-DC1.
CEILING MOUNTED CAMERA BASIS OF DESIGN AVIGILON 4.0C-H5A-DC1-IR.
DRAWING NOTES:
1. COORDINATE EXACT LOCATION OF ALL CEILING MOUNTED DEVICES WITH ARCHITECTURAL RCP AND
ALL OTHER TRADES PRIOR TO CONSTRUCTION.
2. ALL EXTERIOR DOORS TO BE EQUIPPED WITH DOOR CONTACTS FOR MONITORING OF DOOR
POSITION.
0 4' 8' 12' 16'
3/16" = 1'-0"
3/16" = 1'-0"TS101
1 FIRST FLOOR PLAN - ACCESS/INTRUSION/CCTV - WEST
CK
CK
CK
CK
FI
X
M L
CK
RE
RE
DC
CK
RE
RE
CK
RE
CK
RE
RE
DC
DC
FIX
FI
X
FIX
DC
C B A
COMMUNICATIONS
STORAGE
MEDICAL &
GENERAL
STAFF LOUNGE &
LOCKERS
WORKSTATIONS,
MENTAL HEALTH
OFFICE
OFFICE
MECHANICAL
UTILITY CLEAN
UTILITY SOILED
JANITOR CLOSET
ELECTRICAL
ROOM
WP
B.7 A.4
5.5
3.7
3.6
3.3
3.1
2.7
2.5
2.4
1.9
1.5
1.3
WP
1 2 TYPICAL
ROOF HATCH
4 TYPICAL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
BI
M
- C on st ru ct
R ep la ce m en t O ut pa tie nt C lin ic
/0
C on st . R ep la ce . O ut pa tie nt
C lin ic
R
.rv t
2/ 8/
:1
3:
P M
TS102
TECHNOLOGY
ACCESS/CCTV/INTRUSION - EAST
REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2023 JFR CVM
100% CONSTRUCTION
DOCUMENTS
Christopher Van Meter RCDD Reg. No. 285002
3/16" = 1'-0"TS102
1 FIRST FLOOR PLAN - ACCESS/INTRUSION/CCTV - EAST
CODED NOTES:
PROVIDE DOOR CONTACT FOR DOOR MONITORING.
CEILING MOUNTED MOTION SENSOR CONNECTED TO INTRUSION DETECTION SYSTEM. COORDINATE EXACT LOCATION OF DETECTOR WITH ALL CEILING MOUNTED DEVICES PRIOR TO CONSTRUCTION.
DOOR MONITORING WITH HOLD-OPEN ALARM.
CEILING MOUNTED GLASS BREAK SENSOR CONNECTED TO INTRUSION DETECTION SYSTEM.
COORDINATE EXACT LOCATION OF DETECTOR WITH ALL CEILING MOUNTED DEVICES PRIOR TO
CONSTRUCTION.
PATH OF EGRESS DOOR. ACCESS CONTROL SYSTEM SHALL PROVIDE FREE INGRESS AND EGRESS
OF DOOR UPON ACTIVATION OF FIRE ALARM SYSTEM.
DRAWING NOTES:
1. COORDINATE EXACT LOCATION OF ALL CEILING MOUNTED DEVICES WITH ARCHITECTURAL RCP AND
ALL OTHER TRADES PRIOR TO CONSTRUCTION.
0 4' 8' 12' 16'
3/16" = 1'-0"
N
C B
COMMUNICATIONS
T-401
RACK 1 RACK 2 RACK 3
RACK 4
VA POLICE/
PHYSICAL
SECURITY
FUTURE RACK
SPACE
1 TYPICAL
2 2 2 3
5 TYPICAL
20 21
B.7
3.7
3.6
W
T-401
T-401
T-401
T-401
5 TYPICAL
6TYPICAL
20 21
Level 1 119' - 0"
PATCH PANEL COUNTS:
Patch Panels:---------------------------------- Patch Panel Ports:----------------------------
CONNECTED PORT COUNTS:
Data/VOIP Ports:------------------------------
AVAILABLE SPARE PORTS:
Connected Ports Required:------------------ Total Available Ports:------------------------- Available Spare Ports:------------------------
VA DATA/VOIP PATCH PANEL AND PORT COUNTS
14x48
PATCH PANEL COUNTS:
Patch Panels:---------------------------------- Patch Panel Ports:----------------------------
CONNETED PORT COUNTS:
CCTV Ports:------------------------------------
AVAILABLE SPARE PORTS:
Connected Ports Required:------------------ Total Available Ports:------------------------- Available Spare Ports:------------------------
CCTV PATCH PANEL AND PORT COUNTS
1x48
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
B
IM
/0
C o n s tr u c t R e p la c e m e n t O u tp a ti e n t C lin ic
/0
C o n s t.
R e p la c e O u tp a ti e n t C lin ic
R
.r v t
/8
/2
:1
:1
P M
T-401
TECHNOLOGY ENLARGED PLANS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2023 JFR CVM
100% CONSTRUCTION
DOCUMENTS
Christopher Van Meter RCDD Reg. No. 285002
1/2" = 1'-0"1
ENLARGED COMMUNICATIONS RM 152
1/2" = 1'-0"
COMMUNICATIONS RM 152 ELEVATION
CODED NOTES:
PROVIDE TIA APPROVED, FIRE RATED, AC GRADE PLYWOOD BACKBOARD 4'x8'x1/2", OR APPROVED FIRE PLYWOOD. PAINT ON ALL SIDES AND WITHIN CUTOUT AREAS WITH AT LEAST (2) COATS OF FIRE RETARDANT, LIGHT COLORED PAINT. LOCATE BACKBOARD 12" AFF, INSTALL SO 'A' SIDE OF PLYWOOD IS
EXPOSED.
PROVIDE 19" X 30"(MIN) 45RU 4-POST EQUIPMENT RACK. BASIS OF DESIGN IS CHATSWORTH
ADJUSTABLE QUADRARACK 1521-3-E-03 MOUNTING CHANNEL 15217-XXX.
PROVIDE 24" X 42" 42RU 4-POST EQUIPMENT RACK. BASIS OF DESIGN IS TRIPP-LITE SMARTRACK SR42UB
SERIES.
TELECOM MAIN GROUND BUSBAR. ALL VERTICAL AND HORIZONTAL RACKS AND CABLE TRAYS SHALL BE BONDED TO BUSBAR. REFER TO GROUND BUS BAR DETAIL ON SHEET T-501 FOR MORE INFORMATION.
PROVIDE 24"W X 6"H LADDER TYPE CABLE TRAY. MOUNT CABLE TRAY AT 7'-6" AFF TO BOTTOM OF TRAY.
VERTICAL WIRE MANAGERS. BASIS OF DESIGN IS CHATSWORTH 32620-E03, MID PANEL KIT 326005-X03.
(8) 4" SLEEVES THROUGH WALL WITH BUSHINGS ON BOTH SIDES.
1U FIBER OPTIC SHELF WITH (2) 12 FIBER SC CONNECTOR CASSETTES FOR TERMINATION OF INCOMING
FIBER OPTIC CABLES. REFER TO SHEET T-601 FOR ADDITIONAL INFORMATION.
1U NETWORK ROUTER. PROVIDED AND INSTALLED BY VA.
1U, (48) PORT POE+ SWITCH FOR VA NETWORK. SWITCH PROVIDED AND INSTALLED BY VA. BASIS OF
DESIGN IS CISCO 9300.
2U HORIZONTAL CABLE MANAGEMENT. BASIS OF DESIGN CHATSWORTH 35431-X02-E.
1U, (48) PORT, HIGH DENSITY, ANGLED PATCH PANEL. PATCH PANELS TO BE COLOR CODED TO MATCH TCO PORT COLORS; WHITE, YELLOW, AND GREEN. REFER TO SHEETS T-001, T-501 AND T-601 FOR
ADDITIONAL INFORMATION. BASIS OF DESIGN BELDEN AX105365 CAT6A 48 1U.
WIRELESS NETWORK EQUIPMENT. PROVIDED AND INSTALLED BY OTHERS.
VOIP NETWORK EQUIPMENT. PROVIDED AND INSTALLED BY OTHERS.
VA POLICE EQUIPMENT. PROVIDED AND INSTALLED BY OTHERS.
PROVIDE (2) RACK MOUNTED VERTICAL PDUS FOR CONNECTION OF RACK MOUNTED EQUIPMENT. PDUS SHALL HAVE A MINIMUM OF (30) C13, (5) C19 OUTLETS AND BE RATED FOR 5KW MINIMUM. PDU BASIS OF DESIGN IS APC AP7564 (A-SIDE PDU SHALL BE BLACK IN COLOR ON LEFT SIDE OF RACK, B-SIDE PDU
SHALL BE GREY IN COLOR ON RIGHT SIDE OF RACK). CONNECT A-SIDE PDU TO ELECTRICAL
CONNECTION LOCATED ABOVE RACK AND B-SIDE PDU TO UPS OUTPUT. REFER TO ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION. ALL CORD COLORS SHALL MATCH COLOR OF PDU IT IS
CONNECTED TO.
(1) 6KW RACK MOUNTED UPS FOR B-SIDE (CRITICAL) PDU POWER. BASIS OF DESIGN IS APC
SRT6KRMXLT-5KTF WITH (1) ADDITIONAL BATTERY PACK SRT192RMBP.
(2) 4" CONDUITS FROM SITE. TERMINATE CONDUITS 4" AFF. PROVIDE BUSHINGS AND CAPS AT ENDS OF
CONDUITS.
PUBLIC ADDRESS SYSTEM EQUIPMENT. REFER TO SHEET T-601 FOR ADDITIONAL INFORMATION.
CATV PROVIDER DISTRIBUTION EQUIPMENT. PROVIDED AND INSTALLED BY CATV PROVIDER.
NURSE CALL SYSTEM CABINET.
PROVIDE 24"W X 6"H LADDER TYPE CABLE TRAY. MOUNT CABLE TRAY VERTICALLY ON WALL BEGINNING
BELOW CONDUITS THROUGH WALL TO TOP OF CABLE TRAY ABOVE RACKS.
PROVIDE 12"W X 4"H LADDER TYPE CABLE TRAY. MOUNT CABLE TRAY VERTICALLY ON WALL BEGINNING
ABOVE CONDUITS FROM SITE TO BOTTOM OF CABLE TRAY ABOVE RACKS.
ACCESS CONTROL SYSTEM CABINET.
CCTV HEAD END EQUIPMENT AND NETWORK VIDEO RECORDER.
INTRUSION DETECTION SYSTEM HEAD END EQUIPMENT.
110 PUNCH DOWN BLOCK FOR TERMINATION OF INCOMING 96-PAIR CU POTS CABLE.
DRAWING NOTES:
N.T.S.
COMMUNICATIONS RM 152 3D
1" = 1'-0"
RACK 4 ELEVATION
1" = 1'-0"
RACK 3 ELEVATION
1" = 1'-0"
RACK 2 ELEVATION
1" = 1'-0"
RACK 1 ELEVATION
0 1' 2' 4' 6'
1/2" = 1'-0"
0 1' 2' 3'
1" = 1'-0"
1. LABELING STANDARDS SHALL BE FOLLOWED FOR TR NUMBER, RACK NUMBER, PATCH
PANEL (A-Z), AND PORT NUMBER. EXAMPLE: TR1-1A-01.
2. WAP'S SHALL BE TERMINATED ON DATA TYPE PATCH PANELS, BUT TERMINATED ON
THEIR OWN PANELS SEPARATE FROM DATA, VOIP AND ACCESS CONTROL
TERMINATIONS. DATA, VOIP AND ACCESS CONTROL SHALL BE TERMINATED ON DATA
TYPE PATCH PANELS SEPARATE FROM WAP'S. WAP DEVICES, CABLING AND
ASSOCIATED EQUIPMENT PROVIDED AND INSTALLED BY OTHERS.
3. 8P8C CONNECTION PORTS IN TCO WALL PLATES SHALL BE COLOR CODED BASED ON
TYPE. REFER TO SHEET T-001 FOR CABLE COLOR CHART. TCO WALL PLATE PORT AND
CABLE COLOR SHALL MATCH ASSOCIATED PATCH PANEL COLOR.
4. LABEL ALL CABLES AND PORTS ON BOTH ENDS WITH COMPUTER GENERATED, SELF-
LAMINATING, ADHESIVE, WRAPAROUND LABELS WITH THE TCO ROOM NUMBER (101,
102...), AND PORT SEQUENCE NUMBER (001, 002...).
138-001
5. CONTRACTOR SHALL PROVIDE CABLE PULL SCHEDULE FOR EACH SWITCH IN ALL RACKS
AS PART OF SHOP DRAWING SUBMITTAL.
6. PROVIDE SERVICE LOOP, (1) FULL LOOP IN CABLE TRAY AROUND PERIMETER OF DATA
ROOM, FOR ALL STRUCTURED CABLING PRIOR TO TERMINATION ON PATCH PANEL.
7. PATCH PANELS ARE TO BE COLOR CODED WITH THE DATA OUTLET PORT THAT IT IS
ASSOCIATED WITH. YELLOW, GREEN, AND WHITE. REFER TO WALL MOUNTED OUTLET
DETAIL ON SHEET T-501 FOR ADDITIONAL INFORMATION.
PORT SEQUENCE
ROOM NUMBER
MODULAR JACK WIRING (FRONT VIEW)
W-O O W-G BL W-BL G W-BR BR
PAIR3
PAIR2 PAIR1 PAIR4
JACK POSITIONS
TIA/EIA T568B
1 2 3 4 5 6 7 8
VERIFY CAMPUS STANDARD WITH CAMPUS IT REPRESENTATIVE PRIOR TO CONSTRUCTION.
FLOOR SLAB
1" CONDUIT TO ABOVE CEILING
ACCESSIBLE CEILING
(ROUTE CABLE IN CONDUIT ABOVE HARD
CEILINGS.)
J-HOOKS
1" CONCEALED CONDUIT EMT
WALL
FACEPLATE
DEEP 4 SQUARE BOX WITH
SINGLE GANG STEEL PLASTER RING.
3'-5' MAX
CAT6A DATA CABLE
OUTLET DESIGNATOR LABELS
BLANK FACEPLATE FOR FUTURE CONNECTIONS
SINGLE GANG FACEPLATE
FRAME WITH 3 PORTS
(3) UTP 4 PAIR CAT6A CABLES TO TR. CABLE SHALL BE PLENUM OR NON-
PLENUM RATED PER DIVISION 27 SPECIFICATIONS.
1-1/2" CONDUIT STUB UP ABOVE CEILING
NOTES:
1. CABLE LABELING STANDARDS SHALL BE AS INDICATED ON SHEET T-401.
2. 8P8C CONNECTIONS IN WALL PLATES SHALL BE COLOR CODED TO MATCH PATCH PANEL COLORS
AND CABLE COLORS INDICATED ON THIS SHEET AND SHEET T-001.
3. WALL BOX SHALL BE DOUBLE-GANG TELECOMMUNICATIONS-RATED WORK BOX WITH RIGID CONDUIT
EXTENDING TO THE HORIZONTAL PATHWAY.
(3) TIA568B, 8P8C
CAT6A DATA MODULES
107-2
TCO ROOM NUMBER
TCO NUMBERING EXAMPLE:
RM 107, SECOND TCO IN ROOM
YELLOW
WHITE
GREEN
TCO IN ROOM
LENGTH
WIDTH
B
A
NOTES:
"A"
"B" MEASURED FROM MIDDLE OF CROSS SLATS.
MEASURED FROM END OF STRINGER TO MIDDLE OF CROSS SLAT.
UNIVERSAL TUBULAR RUNWAY SYSTEM
CABLE RUNWAY RADIUS DROP
#6 COPPER TO NEXT
SECTION
PROVIDE NUMBER OF SLEEVE AS REQUIRED TO MATCH CABLE TRAY CROSS SECTIONAL AREA. UL W-L 3112
PROVIDE SUPPORTS
WITHIN 12" OF WALL
ON BOTH SIDES
RATED WALL PENETRATION. 1
HOUR FIRE/SMOKE OR GREATER
PACK WITH FIRE SAFING AFTER
CABLE INSTALLATION
CABLE TRAY, REFER
TO DRAWINGS FOR
EXACT SIZE AND TYPE
4" STRAP TO TRAY
PROVIDE APPROPRIATE UL LISTED FIRE
SAFING AT SLEEVE PENETRATIONS OF RATED
WALLS TO RESTORE FIRE RATING OF WALL
4" EMT CONNECTOR
WITH GROUNDING
BOND BUSHING
GROUND WIRE.
MINIMUM #6 COPPER
TO CABLE TRAY
4" SLEEVE (TYPICAL
FOR ALL SLEEVES) QUANTITIES SHOWN ON
FLOOR PLANS.
WALL
NOTES:
1. #3/0 TO PRIMARY PROTECTOR.
2. #3/0 TO ELECTRICAL PANEL.
3. #3/0 TO EQUIPMENT RACKS/CABLE TRAY.
4. TWO-HOLE LUG, IRRIVERSABLE.
TMGB: TELECOMMUNICATIONS MAIN GROUND BUSBAR
TGB: TELECOMMUNICATIONS GROUND BUSBAR
MSB: MAIN SWITCH BOARD
TBB: TELECOMMUNICATIONS BONDING BACKBONE
GENERAL NOTES:
1. BONDING CONDUCTOR SHALL BE NO SMALLER THAN #2 CU.
2. ALL WORK SHALL COMPLY WITH NEC ARTICLE 250, UL 467, ANSI/TIA TIA-607-C, NECA/BICSI 607-2011.
3. PREPARE BUSBAR SURFACE AS DESCRIBED BELOW:
a. USE AN ABRASIVE PAD, REMOVE ANY DIRT, GREASE, OIL OR OXIDATION THAT IS PRESENT AT
THE SURFACE.
b. APPLY THIN COAT OF AN ANTIOXIDANT TO THE CONNECTION POINT ON THE BUSBAR.
c. USE STAINLESS STEEL OR SILICON BRONZE HARDWARE, TIGHTEN AND TORQUE TO THE
REQUIREMENTS OF THE HARDWARE MATERIAL, SIZE AND GRADE.
4. CONDUCTORS SHALL BE COPPER.
5. LUGS SHALL BE 2-HOLE TYPE WITH INSPECTION WINDOW, LONG BARREL, IRREVERSIBLE
(COMPRESSION OR EXOTHERMIC WELDING) AND MECHANICAL.
6. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL GROUNDING INFORMATION.
TBB LENGTH (FT)
TBB CONDUCTOR TABLE
<13
14-20 21-26
TBB SIZE (AWG)
27-33
34-41 42-52
1/0
53-66
67-84 85-105
2/0
3/0 4/0
106-125
126-150 151-175
250 KCMIL
300 KCMIL
350 KCMIL
176-250
251-300 >301
500 KCMIL
600 KCMIL
750 KCMIL
X
ELECTRICAL RM 161
GROUND BUS
MDP
TBB CONDUCTOR PER TABLE
COMM RM 152
TMGB3
0.312Ø (54)
0.437Ø (8) CHATSWORTH "UL"
GROUND BAR LABEL
UL
1' 1/8" TYPICAL
PART NO. 40153-020
1"
1 1/2"
PROVIDE GROUNDING CONDUCTOR TO BUILDINGS STEEL PER TIA-607-B.
PROVIDE GROUNDING CONDUCTOR TO MAIN
SERVICE GROUND POINT PER TIA-607-B.
INSULATOR MOUNTING
BRACKET (TYP.) CPI 10622-000
INSULATOR (TYP)
GENERAL NOTES:
ALL HARDWARE (BOLTS, NUTS, WASHERS,ETC.) SHALL BE SOLID
COPPER OR BRONZE. COPPER PLATING SHALL NOT BE
ACCEPTABLE.
BUSBAR SHALL BE 1/4" THICK (MINIMUM).
1.
INCREASE LENGTH OF BUSBAR, FOR NUMBER OF
CONNECTIONS, AS REQUIRED TO MAINTAIN CORRECT
SPACING BETWEEN LUGS.
2.
3.
CPI 10622-012 OR EQUALPROVIDE # 6 COPPER CABLE 2-HOLE LUG
CLAMP FOR CABLE CONNECTION. (TYP)
2-HOLE LUG (TYP)
TGB-XXX
PROVIDE WHITE CORE BAKELITE NAMEPLATE FASTENED TO A
WALL/SURFACE BELOW BUSBAR AT EACH FLOOR, WITH
DESIGNATION ENGRAVED THEREON IN 1/2" HIGH LETTERS.
INSTALLATION NOTES:
SELECT BOLT LENGTH TO PROVIDE A MINIMUM OF TWO EXPOSED THREADS.A.
BURNISH MOUNTING SURFACE TO REMOVE PAINT IN THE AREA OF LUG CONTACT.B.
APPLY ANTI-OXIDANT COMPOUND TO MATING SURFACE OF LUG AND WIPE CLEAN EXCESS COMPOUND.C.
USE SOLID COPPER WIRE AND MECHANICAL 2-HOLE LUG FOR ALL EXTERIOR GROUNDING.D.
#6 OR #2 GRN TO GROUND BAR OF FLAT SURFACE.
#6 IS USED PRIMARILY AS CABINET TO BUS LINK.
#6 GRN OR #2 GRN 2 HOLE LUG
1/4-20 HEX BOLT
1/4" FLAT WASHER
1/4-20 HEX NUT
1/4" EXT. TOOTH LOCKWASHER
PRIMARY GROUND BAR/
METAL ENCLOSURE
NOTE:
1. CABLE TYPE AND SIZE MUST COMPLY WITH ALL ESTABLISHED REQUIREMENTS AND APPLICABLE CODES.
2. ALL CONDUIT SHALL BE 3/4" UNLESS OTHERWISE NOTED.
3. DOOR HARDWARE SHOWN FOR GRAPHICAL INSTRUCTION ONLY, REFERENCE HARDWARE SCHEDULE AS NEEDED FOR ACTUAL HARDWARE SET.
FINISHED CEILING FINISHED CEILING
CABLE PER MANUFACTURERS
INSTALLATION INSTRUCTIONS. FOR
PROXIMITY CARD READER.
CABLE PER MANUFACTURERS
INSTALLATION INSTRUCTIONS
FOR LATCH MONITORING &
REQUEST TO EXIT.
CARD READER OR KEYPAD
PROVIDE 2-GANG BOX WITH
SINGLE GANG MUD RING
MOUNTED VERTICALLY.
REFERENCE FLOOR PLANS
FOR REQUIRED PLACEMENT
AND DEVICE TYPE.
UNSECURE SIDE SECURE SIDE
6"
" A
.F .F
TO ACCESS
CONTROL
EQUIPMENT IN
COMM ROOM 161
CABLE FOR COMMUNICATION AND
LOW VOLTAGE POWER CABLE PER
MANUFACTURERS INSTALLATION
INSTRUCTIONS.
FINISHED FLOOR
6" x 6" x 4" J-BOX
CABLE PER MANUFACTURERS
INSTALLATION INSTRUCTIONS
FOR MAGNETIC CONTACT
MAGNETIC DOOR
CONTACT SWITCH
EMBEDDED IN DOOR &
DOOR FRAME
SHUNT FOR MAGNETIC
DOOR POSITION SWITCH,
INTEGRATED IN DOOR
HARDWARE
CONDUCTORS FOR
ELECTRIFIED LOCKSET
WITH INTERNAL
REQUEST TO EXIT.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10 www.abovegroupinc.com COA/CA Lic. No. 31120
FULLY SPRINKLERED305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
BI
M
- C on st ru ct
R ep la ce m en t O ut pa tie nt C lin ic
/0
C on st . R ep la ce . O ut pa tie nt
C lin ic
R
.rv t
2/ 8/
:1
2:
P M
T-501
TECHNOLOGY DETAILS REPLACEMENT OUTPATIENT
CLINIC DESIGN AT COAST
GUARD CAPE COD
JOINT BASE CAPE COD, BARNSTABLE MA
650-318
BUILDING 1
02/10/2023 JFR CVM
100% CONSTRUCTION
DOCUMENTS
Christopher Van Meter RCDD Reg. No. 285002
N.T.S.
MODULAR JACK WIRING DETAIL1
N.T.S.
TYPICAL FLUSH OUTLET MOUNTING2
N.T.S.
WALL MOUNTED OUTLET - (TCO) VOICE/DATA3
N.T.S.
TUBULAR RUNWAY/LADDER RACK IN TR'S4
N.T.S.
TYPICAL CABLE TRAY WALL PENETRATION5
N.T.S.
TELECOM GROUNDING RISER DIAGRAM6
N.T.S.
GROUND BUS BAR (TYP FOR ALL TR'S)7
N.T.S.
GROUND BAR 2-HOLE LUG TERMINATION8
N.T.S.
SE…