ATTACHMENT 4 - FINAL DRAWINGS - CLC RENO SPOKANE - PART 2 of 3.pdf

PDF 16 MB Posted

Attached to
Y1DZ--668-318 Renovate and Expand Community Living Center Minor Construction - Spokane VAMC
Solicitation number
36C77623B0071
Issued by

About this file

This file attachment is related to the federal contract opportunity solicitation number 36C77623B0071 from the Department of Veterans Affairs Technology Acquisition Center Austin to renovate and expand the Community Living Center at the Spokane Veterans Affairs Medical Center.

The file attachment contains final drawings for the renovation and expansion project in three parts. The solicitation is for a minor construction project to upgrade facilities and increase capacity at the Spokane VA medical center. Interested contractors should review the drawings in this attachment along with the full solicitation document to understand the scope of work required, which includes renovations to existing buildings as well as additions. The response due date and planned award date are not provided in this file attachment but can be found in the related solicitation.

View the file

Other files

File Type Posted
Wage Determination WDWA20230017 MOD4.pdf PDF
36C77623B0071 0006.docx DOCX document
EP612 12.11.2023.pdf PDF
36C77623B0071 0005.docx DOCX document
MP103 12.12.2023.pdf PDF
CLC Technical Response Tracking Spreadsheet - 12.13.2023.pdf PDF
MH701 12.12.2023.pdf PDF
MH603 12.12.2023.pdf PDF
36C77623B0071 0004.docx DOCX document
Question 97 - formatrac-bendable-track_specifications-ipc.1196-rev9.pdf PDF
CLC Technical Response Tracking Spreadsheet - 12.4.2023.pdf PDF
Question 82 - CO-Series-Product-Sheet-PS-CO8 (1).pdf PDF
36C77623B0071 0003.docx DOCX document
Question 5 and 64 - 09 29 00 - Gyp Board.pdf PDF
CLC Technical Response Tracking Spreadsheet - FINAL.pdf PDF
Question 67 - Spokane Design Requirements - Design Amendments May 2021.pdf PDF
CLC - Master Submittal Register (Responding to item 4 on VA email from 11.15.2023.pdf PDF
Question 44 - Links word and excel Statement of SI Temp.pdf PDF
Lift count - CLC Spokane - 100_ CD Drawings_.pdf PDF
LIFT INFORMATION - LI-WVA-019-04- Existing Lifts .pdf PDF
Amendment 0002 Technical Question Tracker.pdf PDF
36C77623B0071 0002.docx DOCX document
LQ-610380-07 NEW LIFT INFO.pdf PDF
SF1442 Page 2 - Signature Page.pdf PDF
CLC Technical Response Tracking Spreadsheet - 10-26-2023.pdf PDF
Wage Determination WDWA20230017 MOD2.pdf PDF
Completed Site Visit Sign-In Sheet 10-17-23.pdf PDF
36C77623B0071 0001.docx DOCX document
ATTACHMENT 7 - DAVIS-BACON ACT WAGE DETERMINATION WDWA20230017 MOD1.pdf PDF
ATTACHMENT 1 - FINAL SPECIFICATIONS - CLC RENO SPOKANE - PART 1 of 2.pdf PDF
ATTACHMENT 5 - FINAL DRAWINGS - CLC RENO SPOKANE - PART 3 of 3.pdf PDF
ATTACHMENT 2 - FINAL SPECIFICATIONS - CLC RENO SPOKANE - PART 2 of 2.pdf PDF
ATTACHMENT 3 - FINAL DRAWINGS - CLC RENO SPOKANE - PART 1 of 3.pdf PDF
ATTACHMENT 6 - LIMITATIONS ON SUBCONTRACTING.docx DOCX document
ATTACHMENT 8 - SITE VISIT INSTRUCTIONS.pdf PDF
36C77623B0071.docx DOCX document
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

201761

T

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

T

3 APRIL 2023

GENERAL ABBREVIATIONS:

ABA ARCHITECTURAL BARRIERS ACT

ABV ABOVE

ACT ACOUSTICAL CEILING TILE

A/E ARCHITECT / ENGINEER

AFF ABOVE FINISHED FLOOR

ALT ALTERNATE

APPROX APPROXIMATE

ARCH ARCHITECT(URAL)

AI ACQUISITION / INSTALLATION

BD BOARD

BL BUILDING LINE

BLDG BUILDING

B.O. BOTTOM OF

C/C CONTRACTOR FURNISHED AND

CONTRACTOR INSTALLED

CF CUBIC FOOT

CFS CUBIC FEET PER SECOND

CG CORNER GUARD

CI CONTINUOUS INSULATION

CMU CONCRETE MASONRY UNIT

COR CONTRACTING OFFICER'S

CR CHAIR RAIL

CONC CONCRETE

CONST CONSTRUCTION

CU IN CUBIC INCH

CU YD CUBIC YARD

DEMO DEMOLITION

DET DETAIL

DIA, Ø DIAMETER

DR DOOR

DWG(S) DRAWING(S)

E EAST

EA EACH

EIFS EXTERIOR INSULATION FINISHING SYSTEM

ELEC ELECTRIC(AL)

ELEV ELEVATION

EQ EQUAL

EXIST EXISTING

EXP EXPOSED

EXP. JT EXPANSION JOINT

EXT EXTERIOR

FRP FIBERGLASS REINFORCED PLASTIC

FIN FINISH

FIN FL FINISHED FLOOR

FIN FL ELEV FINISHED FLOOR ELEVATION

FRPT FIRE-RETARDANT PRESSURE TREATED

FL FLOOR

FO FACE OF

FOC FACE OF CONCRETE

FOM FACE OF MASONRY

FOS FACE OF STUDS

FT FLOOR TRANSITION

GFGI GOVERNMENT FURNISHED, GOVERNMENT

INSTALLED

GL GLASS

GSF GROSS SQUARE FEET

GYP GYPSUM

GRT GROUT

GWB GYPSUM WALL BOARD

HAC HOUSEKEEPING AIDS CLOSET

HM HOLLOW METAL

HORZ HORIZONTAL

HT HEIGHT

HR HAND RAIL

INC INCORPORATED

INFO INFORMATION

INT INTERIOR

LG LENGTH / LONG

LS LINER SYSTEM

LVT LUXURY VINYL TILE

M METER(S)

MAX MAXIMUM

MECH MECHANIC(AL)

MED MEDIUM

MTL METAL

MFR MANUFACTURE(R)

MIN MINIMUM

MISC MISCELLANEOUS

MM MILLIMETER

MR MOISTURE RESISTANT

N/A NOT APPLICABLE

N NORTH

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NOM NOMINAL

NPS NATIONAL PARK SERVICE

NSF NET SQUARE FEET

NTS NOT TO SCALE

OC ON CENTER

OFF OFFICE

OPOI OWNER PROVIDED, OWNER INSTALLED

OPP OPPOSING HAND

P PAINT

PC PRIVACY CURTAIN

PCF POUNDS PER CUBIC FOOT

PEMB PRE-ENGINEERED METAL BUILDING

PLF POUNDS PER LINEAL FOOT

PFN PRE-FINISHED

PH PHASE

PLAM PLASTIC LAMINATE

PLUM PLUMBING

PT PAINT

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

RAD RADIUS

RB RUBBER WALL BASE

RCP REFLECTED CEILING PLAN

RE REFER TO, REFERENCE

RO ROUGH OPENING

ROW RIGHT OF WAY

S SOUTH

SAFB SOUND ATTENUATING FIRE BLANKET

SCH SCHEDULE

SECT SECTION

SF SQUARE FEET

SHT SHEET

SIM SIMILAR

SPEC SPECIFICATION(S)

SQ SQUARE

SS STAINLESS STEEL

SSF SOLID SURFACE

STC SOUND TRANSMISSION CLASS

STD STANDARD

STOR STORAGE

STRUC STRUCTURE / STRUCTURAL

T TILE

TELECOM TELECOMMUNICATIONS

TEF TEXTURED EPOXY FLOORING

T.O. TOP OF

TYP TYPICAL

UL UNDERWRITER'S LABORATORIES, INC.

UNO UNLESS NOTED OTHERWISE

VA VETERANS ADMINISTRATION

VERT VERTICAL

VIF VERIFY IN FIELD

VOC VOLITILE ORGANIC COMPOUND

VC VA FURNISHED AND CONTRACTOR INSTALLED

V/V VA FURNISHED AND VA INSTALLED

W WEST / WIDTH / WIDE

WB WALL BASE

WD WOOD DOOR

W/ WITH

W/O WITHOUT

WM WALK OF MAT

WS WINDOW SHADE

WP WALL PROTECTION

WT WEIGHT

YD YARD

YR YEAR

XX###

SIM

XX###

DETAIL NUMBER

SHEET REFERENCE

TYPICAL CALLOUT BUBBLE

EXTERIOR ELEVATION TAG

XX###

SIM

____________________________________________________________________________________SECTION CUT

XX###

INTERIOR ELEVATION TAG

DETAIL NUMBER

SHEET REFERENCE

ROOM NAME

### SF

ROOM TAG

ASSIGNED ROOM DESIGNATOR

ASSIGNED ROOM NUMBER

ROOM SQUARE FOOTAGE

XX###

ENLARGED PLAN / DETAIL CALLOUT

Name Elevation ELEVATIONS / LEVELS

ELEVATION LOCATION

ELEVATION LOCATION

ELEVATION TAG

FINISH ELEVATION

ROUGH ELEVATION

CENTER LINE

NORTH ARROW

XX###

VIEW TITLE

SCALE: 1/8" = 1'-0"

VIEW TITLE

DRAWING TITLE

DRAWING SCALE

1REVISION TAG

REVISION CLOUD

0STRUCTURAL GRID

0GRID DESIGNATOR

GRID LINE

KEY NOTE TAG

SYMBOLS LEGEND:

DOOR TAG

WINDOW TAG

XXX

XX

ABA CLEARANCE AREAS

NTN

NAME

ELEVATION

PARTITION TAG XX

XXTOILET ACCESSORY TAG

GENERAL MATERIALS LEGEND:

CONCRETE

CONCRETE MASONRY

EARTH

RIGID INSULATION

BATT INSULATION

ARCHITECTURAL GENERAL NOTES:

BECOME FAMILIAR WITH THE CONSTRUCTION DOCUMENTS AND NOTIFY THE VA

COR OF DISCREPANCIES BEFORE PROCEEDING WITH WORK.

FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO ORDERING OR

INSTALLING MATERIALS OR EQUIPMENT.

DAMAGED AREAS CAUSED DURING CONSTRUCTION SHALL BE REPAIRED OR

REPLACED AT THE CONTRACTOR'S EXPENSE. REPAIRS SHALL MATCH EXISTING

CONSTRUCTION MATERIALS AND FINISHES.

THE CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF

DEMOLITION AND/OR CONSTRUCTION DEBRIS ASSOCIATED WITH THE WORK.

DISPOSAL MUST BE IN COMPLIANCE WITH FEDERAL, STATE, AND LOCAL

REGULATIONS. THE PROJECT SITE MUST BE KEPT CLEAN AND FREE FROM WASTE

MATERIALS.

THE OWNER SHALL RESERVE THE RIGHT TO SALVAGE MATERIALS PRIOR TO

CONTRACTOR REMOVAL OR DEMOLITION.

PENETRATIONS THROUGH WALL CONSTRUCTION SHALL BE FULLY SEALED AT ALL

SIDES.

JOINTS AND WALL TERMINATIONS MUST BE SEALED. SCRIBE GYPSUM BOARD AT

THE TOP-OF-WALL TO MATCH IRREGULARITIES AND ROOF PROFILE ABOVE.

FULL HEIGHT NON-BEARING INTERIOR PARTITIONS MUST PROVIDE FOR 1-INCH

VERTICAL MOVEMENT OF THE BUILDING STRUCTURE WITHOUT TRANSFER OF

COMPRESSIVE LOADS TO THE WALL.

COORDINATE AND INSTALL FIRE-TREATED WOOD BLOCKING OR SHEET METAL

BACKING FOR ANCHORAGE OF WALL-MOUNTED ITEMS.

COORDINATE MECHANICAL ROOF AND WALL DUCT PENETRATIONS WITH

MECHANICAL SUB-CONTRACTOR.

THE UNDERCUT ON FIRE-RESISTIVE DOORS MUST NOT EXCEED 3/4 INCH. SMOKE

SEALS MUST BE INSTALLED ON THE DOOR FRAME AT BOTH JAMBS AND HEAD.

GYPSUM BOARD PARTITIONS MUST EXTEND A MINIMUM OF 6 INCHES ABOVE

FINISHED CEILING PLANE UNLESS NOTED OTHERWISE.

NO WORK SHALL BE COVERED OR CONCEALED UNTIL IT HAS BEEN INSPECTED,

TESTED, AND/OR APPROVED BY THE AUTHORITIES HAVING JURISDICTION.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

4/ 3/

:4

2:

P M

AI001

ABBREVIATIONS, GENERAL NOTES,

LEGEND, AND SYMBOLS

APRIL 2023 BAJ LMF

34 183

DAVID ARMENT

509-964-1889

David.Arment@va.govREVISIONS DATE

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

T

3 APRIL 2023

2 2

5 5

6 6

7 7

A B C D E F

G

H

J

K

L

M

N

B.1 C.7 F.1

TD

6'-

0" (s ou th

TD105'-0"

TD

195'-0" (east)

CP

32'-0"

C P

'-0

TD

0'-

0"

177'-0" 9 (west)

1'-

0" (e as t)

CP

'-0

AREA OF

NEW ADDITION

AREA OF RENOVATION

FACPEXIST.

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

FEC

F E

C

FEC

FEC

FEC

FEC

SB

SB

SB

SB

SB

SB

SB

SB

SB SB

SB

SB

SB

SB

SB

TD

142'-0"

TD188'-0"

LIFE SAFETY LEGEND:

XX

PATH OF TRAVEL DISTANCE

XX - INDICATES MAX DISTANCE

FIRE EXTINGUISHER ON BRACKET

FIRE EXTINGUISHER IN CABINET

EXIT

EXIT LIGHT

FEB

FEC

TD

XX

COMMON PATH

XX - INDICATES MAX DISTANCE

CP

AREA NOT IN SCOPE

SLEEPING DEPARTMENTS

HEALTH CARE

SB

ONE HOUR FIRE-RESISTIVE

RATED WALL

ONE HOUR SMOKE BARRIER WALL

AREA OF NEW ADDITION

FIRE ALARM CONTROL PANELFACP

AREA OF RENOVATION IN

EXISTING FACILITY

TWO HOUR FIRE-RESISTIVE

RATED WALL

XX

PATH OF TRAVEL DIST. (COURTYARD)

XX - INDICATES MAX DISTANCE

TD

NOTE:

PROVIDE ACCESS TO MEANS OF EGRESS DURING

CONSTRUCTION:

EAST WING

1. DEMO EXISTING WINDOW AND INSTALL NEW

EGRESS DOORS E001 AND S001 , REFER TO

ARCHITECTURAL, ELECTRICAL, AND TELECOM

DRAWINGS.

WEST WING

2. RELOCATE WEST WING PATIENTS TO EAST

WING AFTER CONSTRUCTION ITEMS FROM

EAST WING EGRESS DOORS HAVE BEEN

INSTALLED AND MADE OPERATIONAL.

SOUTH WING

3. LIMITED ACCESS TO COURTYARD DURING

CONSTRUCTION UNTIL DOORS (S003B AND

S114A) HAVE BEEN INSTALLED AS

OPERATIONAL.

BUILDING CODE SUMMARY:

APPLICABLE CODES AND STANDARDS:

2018 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS

2019 NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS

2020 NFPA 70 NATIONAL ELECTRICAL CODE

2019 NFPA 72 NATIONAL FIRE ALARM CODE

2018 NFPA 101 LIFE SAFETY CODE

2019 NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS

ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS)

VA DESIGN CRITERIA PG 18-10, FIRE PROTECTION, 8TH ED. JUNE 1, 2021

OCCUPANCY CLASSIFICATION:

NEW HEALTH CARE (NFPA 101 CHAPTER 18)

THE HEALTH CARE FACILITIES REGULATED BY THIS CHAPTER SHALL BE THOSE

THAT PROVIDE SLEEPING ACCOMODATIONS FOR THEIR OCCUPANTS AND ARE

OCCUPIED BY PERSONS WHO ARE MOSTLY INCAPABLE OF SELF-PRESERVATION

BECAUSE OF AGE, PHYSICAL OR MENTAL DISABILITY, OR BECAUSE OF SECURITY

MEASURES NOT UNDER THE OCCUPANTS' CONTROL.

BUILDING FLOOR AREAS:

NORTH WING 14,7435 GSF (EXISTING)

WEST WING 6,536 GSF (EXISTING)

EAST WING 7,691 GSF (EXISTING)

SOUTH WING 9,258 GSF (ADDITION)

SUBDIVISION OF BUILDING SPACE: (NFPA SECTION 18.3.7)

ALLOWABLE SMOKE COMPARTMENT AREA 22,500 SF

BUILDING HEIGHT / NO. STORIES: (NFPA 101 TABLE 18.1.6.1)

ALLOWABLE HEIGHT: 1 STORY (TYPE II (000) SPRINKLERED)

PROPOSED HEIGHT: 1 STORY

SEPARATIONS:

FIRE SEPARATION: THE 2-HR FIRE SEPARATION BETWEEN NEW

AND EXISTING CONSTRUCTION DOES NOT

APPLY DUE TO SAME ADJOINING

CONSTRUCTION TYPES

(NFPA 101 SECTION 8.2.1.3).

SMOKE BARRIER: SMOKE COMPARTMENTS NOT MORE THAN

40,000 SF (NFPA 101 SECTION 18.3.7.1).

TRAVEL DISTANCE FROM ANY POINT TO

REACH A DOOR IN REQUIRED SMOKE

BARRIER SHALL NOT EXCEED 200 FEET

(NFPA 101 SECTION 18.3.7.1).

ANY REQUIRED SMOKE BARRIER -

MIN. 1 HOUR FIRE RESISTANCE RATED

(NFPA 101 SECTION 18.3.7.3).

SMOKE SEPARATION: SMOKE PARTITIONS AT SOILED LINEN -

EXCEEDING 64 GAL.

(NFPA 101SECTION 18.3.2.1.2).

OCCUPANCY LOAD: (NFPA 101 TABLE 7.3.1.2)

FUNCTION OF SPACE AREA OCC. LOAD OCCUPANTS

HEALTH CARE USE:

INPATIENT TREATMENT - - -

SLEEPING DEPARTMENTS 10,102 120 85

AMBULATORY HEALTH CARE 6,016 150 56

TOTAL OCCUPANTS 141

MEANS OF EGRESS: (NFPA 101 SECTION 7.1)

MINIMUM NUMBER OF EXITS REQUIRED = 2 EXITS PER BUILDING

ACTUAL EXISTS PROVIDED = 4 EXITS

(MECHANICAL ROOM EXIT IS NOT INCLUDED IN THIS VALUE)

MAX. TRAVEL DISTANCE = 200 FEET (NFPA 101) SECTION 18.2.6.2.1

ACTUAL TRAVEL DISTANCE (MAX.) = 177 FEET

MAX. TRAVEL DISTANCE IN SLEEPING

ROOM TO EXIT ACCESS DOOR = 50 FEET (NFPA 101) SECTION 18.2.6.3

ACTUAL TRAVEL DISTANCE (MAX.) = 32 FEET

EXIT WIDTH CAPACITY: (NFPA 101) TABLE 7.3.3.1)

DOOR CAPACITY 159 X .3 = 48 INCHES

FIRE ALARM SYSTEM: (NFPA 101 SECTION 9.7.2)

FOR FIRE ALARM SYSTEM, REFER TO FIRE ALARM DRAWINGS

FIRE SPRINKLER SYSTEM: (NFPA 101 SECTION 9.7)

FULLY SPRINKLERED, REFER TO FIRE PROTECTION DRAWINGS

PORTABLE FIRE EXTINGUISHERS: (NFPA 10)

CABINETS MUST NOT PLACE EXTINGUISHER HANDLES MORE THAN

48" ABOVE FINISHED FLOOR. FIRE EXTINGUISHERS AND CABINETS

SHALL BE LOCATED AS REQUIRED BY NFPA 10, SEE CURRENT SHEET

AL100 FOR LOCATIONS.

INTERIOR FINISH: (NFPA 101 SECTION 18.3.3)

INTERIOR FINISH SHALL BE IN ACCORDANCE WITH NFPA 101

SECTION 10.2, AND CONTENTS AND FURNISHINGS SHALL BE IN

ACCORDANCE WITH PER NFPA 101 SECTION 10.3

CONSTRUCTION TYPE: (NFPA 220 TABLE 4.1.1)

TYPE II (000)

FULLY SPRINKLERED

ONE STORY

TN N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

4/ 3/

:4

2:

P M

AL100

LIFE SAFETY PLAN AND BUILDING

CODE SUMMARY

APRIL 2023 BAJ RJF

35 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

SCALE: 1/16" = 1'-0"

LIFE SAFETY FLOOR PLAN - OVERALL1

32'8'

SCALE:1/16"=1'-0"

0 16'

REVISIONS DATE

A B C D E F

G

H

J

K

L

M

N

AD101

AD102

DEMOLITION SHEET NOTES:

WORK TO BE COMPLETED IN COMPLIANCE WITH

APPLICABLE CODES AND TO THE SATISFACTION OF THE

COR.

PROTECT EXISTING CONSTRUCTION TO REMAIN FROM

CONSTRUCTION ACTIVITIES.

EXAMINE AND VERIFY DIMENSIONS AND EXISTING

CONDITIONS BOTH ON PLAN AND IN THE FIELD PRIOR TO

COMMENCEMENT OF CONSTRUCTION. VERIFY WHETHER

FIELD DIMENSIONS WILL TAKE PRECEDENCE OVER

DRAWING DIMENSIONS. DO NOT SCALE FROM DRAWINGS.

COORDINATE THE REMOVAL AND/OR RELOCATION OF

FIXTURES, EQUIPMENT, AND OTHER APPURTENANCES

WITH COR. CONTRACTOR IS NOT REQUIRED TO PROVIDE

MOVING OR RELOCATION OF RESIDENT SERVICES. THE

WEST WING WILL BE VACATED BY GOVERNMENT PRIOR

TO THE START OF WORK.

THE CONTRACTOR WILL BE RESPONSIBLE FOR REMOVING

STORING ITEMS OFFSITE AND EQUIPMENT PRIOR TO

COMMENCEMENT OF WORK. ITEMS TO BE REMOVED WILL

BE IDENTIFIED BY THE COR PRIOR TO START OF

CONSTRUCTION.

PATCH, REPAIR, REPLACE, AND REPAINT AREAS OF

EXISTING CONSTRUCTION AFFECTED BY DEMOLITION TO

NEW CONDITION. MATCH THE EXISTING ADJACENT

CONSTRUCTION AND MATERIAL TO GREATEST EXTENT

POSSIBLE, INCLUDING BUT NOT LIMITED TO: FLOORS,

WALLS, AND CEILINGS.

REMOVE MECHANICAL, PLUMBING, ELECTRICAL

EQUIPMENT AND ASSOCIATED DEVICES PER DISIPLINE

DEMOLITION SHEETS.

EXISTING STRUCTURAL COMPONENTS ARE TO REMAIN IN

PLACE ALONG WITH EXISTING FACP, UNO.

CONTRACTOR TO REMOVE EXISTING LIFT SYSTEMS

CAREFULLY AND STORED AND INVENTORIED OFF SITE

FOR REUSE IN NEW CONSTRUCTION.

1.

2.

3.

4.

5.

6.

7.

8.

9.

DEMOLITION LEGEND:

WALLS TO BE DEMOLISHED

DOORS TO BE DEMOLISHED

WINDOWS TO BE DEMOLISHED

REMOVE ALL EXISTING CEILING FIXTURES,

EXISTING GYPSUM BOARD CEILING AND

ASSOCIATED FRAMING COMPONENTS.

NOT IN SCOPE.

LIMITED WORK TO UTILITIES FOR SUPPORT

AND CONNECTIONS (ALONG WITH SUSPENDED

CEILING REMOVAL AND REPLACEMENT IN

NORTH WING LOCATIONS).

LIMITED WORK ON EXTERIOR WALLS AND

DOORS TO PROVIDE TWO EGRESS DOORS AT

EAST WING.

TN N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

7/ 5/

0:

:2

A

M

AD100

DEMOLITION FLOOR PLAN - OVERALL

APRIL 2023 BAJ LMF

DAVID ARMENT

509-964-1889

David.Arment@va.gov

SCALE: 1/16" = 1'-0"

DEMOLITION FLOOR - OVERALL1

32'8'

SCALE:1/16"=1'-0"

0 16'

REVISIONS DATE 36

201761

T

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

5 JULY 2023

F

HJKLMN

2D

1D

2'

0"

2'

0"

DEMOLITION SHEET NOTES:

WORK TO BE COMPLETED IN COMPLIANCE WITH

APPLICABLE CODES AND TO THE SATISFACTION OF THE

COR.

PROTECT EXISTING CONSTRUCTION TO REMAIN FROM

CONSTRUCTION ACTIVITIES.

EXAMINE AND VERIFY DIMENSIONS AND EXISTING

CONDITIONS BOTH ON PLAN AND IN THE FIELD PRIOR TO

COMMENCEMENT OF CONSTRUCTION. VERIFY WHETHER

FIELD DIMENSIONS WILL TAKE PRECEDENCE OVER

DRAWING DIMENSIONS. DO NOT SCALE FROM DRAWINGS.

COORDINATE THE REMOVAL AND/OR RELOCATION OF

FIXTURES, EQUIPMENT, AND OTHER APPURTENANCES

WITH COR. CONTRACTOR IS NOT REQUIRED TO PROVIDE

MOVING OR RELOCATION OF RESIDENT SERVICES. THE

WEST WING WILL BE VACATED BY GOVERNMENT PRIOR

TO THE START OF WORK.

THE CONTRACTOR WILL BE RESPONSIBLE FOR REMOVING

STORING ITEMS OFFSITE AND EQUIPMENT PRIOR TO

COMMENCEMENT OF WORK. ITEMS TO BE REMOVED WILL

BE IDENTIFIED BY THE COR PRIOR TO START OF

CONSTRUCTION.

PATCH, REPAIR, REPLACE, AND REPAINT AREAS OF

EXISTING CONSTRUCTION AFFECTED BY DEMOLITION TO

NEW CONDITION. MATCH THE EXISTING ADJACENT

CONSTRUCTION AND MATERIAL TO GREATEST EXTENT

POSSIBLE, INCLUDING BUT NOT LIMITED TO: FLOORS,

WALLS, AND CEILINGS.

REMOVE MECHANICAL, PLUMBING, ELECTRICAL

EQUIPMENT AND ASSOCIATED DEVICES PER DISIPLINE

DEMOLITION SHEETS.

EXISTING STRUCTURAL COMPONENTS ARE TO REMAIN IN

PLACE ALONG WITH EXISTING FACP, UNO.

CONTRACTOR TO REMOVE EXISTING LIFT SYSTEMS

CAREFULLY AND STORED AND INVENTORIED OFF SITE

FOR REUSE IN NEW CONSTRUCTION.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY NOTES:

DEMOLISH EXISTING ALUMINUM CURTAIN WALL SYSTEM

WITH GLASS DOOR AND SIDE LITES.

REMOVE EXISTING WINDOW AND PORTION OF EXISTING

WALL TO ALLOW FOR ALUMINUM STOREFONT DOOR

INSTALLATION, SEE DOOR SCHEDULE.

1D.

2D

NOT IN SCOPE.

NORTH WING - LIMIT WORK TO UTILITIES

FOR SUPPORT AND CONNECTIONS ALONG

WITH SUSPENDED CEILING REMOVAL AND

REPLACEMENT.

EAST WING - LIMIT WORK ON EXTERIOR

WALLS AND DOORS TO PROVIDE TWO

EGRESS DOORS, AND COMM/ELECTRICAL

ROOMS.

TN

N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

7/ 5/

0:

:2

A

M

AD101

DEMOLITION FLOOR PLAN - EAST

WING

APRIL 2023 BAJ LMF

37 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

SCALE: 1/8" = 1'-0"

DEMOLITION FLOOR PLAN - EAST WING1

8'0 4' 16'

SCALE:1/8"=1'-0"

REVISIONS DATE

201761

T

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

T

3 APRIL 2023

F

HJKLMN

2D

1D

2'

0"

2'

0"

DEMOLITION SHEET NOTES:

WORK TO BE COMPLETED IN COMPLIANCE WITH

APPLICABLE CODES AND TO THE SATISFACTION OF THE

COR.

PROTECT EXISTING CONSTRUCTION TO REMAIN FROM

CONSTRUCTION ACTIVITIES.

EXAMINE AND VERIFY DIMENSIONS AND EXISTING

CONDITIONS BOTH ON PLAN AND IN THE FIELD PRIOR TO

COMMENCEMENT OF CONSTRUCTION. VERIFY WHETHER

FIELD DIMENSIONS WILL TAKE PRECEDENCE OVER

DRAWING DIMENSIONS. DO NOT SCALE FROM DRAWINGS.

COORDINATE THE REMOVAL AND/OR RELOCATION OF

FIXTURES, EQUIPMENT, AND OTHER APPURTENANCES

WITH COR.

THE CONTRACTOR WILL BE RESPONSIBLE FOR REMOVING

STORING ITEMS OFFSITE AND EQUIPMENT PRIOR TO

COMMENCEMENT OF WORK. ITEMS TO BE REMOVED WILL

BE IDENTIFIED BY THE COR PRIOR TO START OF

CONSTRUCTION.

PATCH, REPAIR, REPLACE, AND REPAINT AREAS OF

EXISTING CONSTRUCTION AFFECTED BY DEMOLITION TO

NEW CONDITION. MATCH THE EXISTING ADJACENT

CONSTRUCTION AND MATERIAL TO GREATEST EXTENT

POSSIBLE, INCLUDING BUT NOT LIMITED TO: FLOORS,

WALLS, AND CEILINGS.

REMOVE MECHANICAL, PLUMBING, ELECTRICAL

EQUIPMENT AND ASSOCIATED DEVICES PER DISIPLINE

DEMOLITION SHEETS.

EXISTING STRUCTURAL COMPONENTS ARE TO REMAIN IN

PLACE ALONG WITH EXISTING FACP, UNO.

CONTRACTOR TO REMOVE EXISTING LIFT SYSTEMS

CAREFULLY AND STORED AND INVENTORIED OFF SITE

FOR REUSE IN NEW CONSTRUCTION.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY NOTES:

DEMOLISH EXISTING ALUMINUM CURTAIN WALL SYSTEM

WITH GLASS DOOR AND SIDE LITES.

REMOVE EXISTING WINDOW AND PORTION OF EXISTING

WALL TO ALLOW FOR ALUMINUM STOREFONT DOOR

INSTALLATION, SEE DOOR SCHEDULE.

1D.

2D

NOT IN SCOPE.

NORTH WING - LIMIT WORK TO UTILITIES

FOR SUPPORT AND CONNECTIONS ALONG

WITH SUSPENDED CEILING REMOVAL AND

REPLACEMENT.

EAST WING - LIMIT WORK ON EXTERIOR

WALLS AND DOORS TO PROVIDE TWO

EGRESS DOORS, AND COMM/ELECTRICAL

ROOMS.

TN

N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

4/ 3/

:1

4:

P M

AD101

DEMOLITION FLOOR PLAN - EAST

WING

APRIL 2023 BAJ LMF

37 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

SCALE: 1/8" = 1'-0"

DEMOLITION FLOOR PLAN - EAST WING1

8'0 4' 16'

SCALE:1/8"=1'-0"

DEMOLITION SHEET NOTES:

WORK TO BE COMPLETED IN COMPLIANCE WITH

APPLICABLE CODES AND TO THE SATISFACTION OF THE

COR.

PROTECT EXISTING CONSTRUCTION TO REMAIN FROM

CONSTRUCTION ACTIVITIES.

EXAMINE AND VERIFY DIMENSIONS AND EXISTING

CONDITIONS BOTH ON PLAN AND IN THE FIELD PRIOR TO

COMMENCEMENT OF CONSTRUCTION. VERIFY WHETHER

FIELD DIMENSIONS WILL TAKE PRECEDENCE OVER

DRAWING DIMENSIONS. DO NOT SCALE FROM DRAWINGS.

COORDINATE THE REMOVAL AND/OR RELOCATION OF

FIXTURES, EQUIPMENT, AND OTHER APPURTENANCES

WITH COR. CONTRACTOR IS NOT REQUIRED TO PROVIDE

MOVING OR RELOCATION OF RESIDENT SERVICES. THE

WEST WING WILL BE VACATED BY GOVERNMENT PRIOR

TO THE START OF WORK.

THE CONTRACTOR WILL BE RESPONSIBLE FOR REMOVING

STORING ITEMS OFFSITE AND EQUIPMENT PRIOR TO

COMMENCEMENT OF WORK. ITEMS TO BE REMOVED WILL

BE IDENTIFIED BY THE COR PRIOR TO START OF

CONSTRUCTION.

PATCH, REPAIR, REPLACE, AND REPAINT AREAS OF

EXISTING CONSTRUCTION AFFECTED BY DEMOLITION TO

NEW CONDITION. MATCH THE EXISTING ADJACENT

CONSTRUCTION AND MATERIAL TO GREATEST EXTENT

POSSIBLE, INCLUDING BUT NOT LIMITED TO: FLOORS,

WALLS, AND CEILINGS.

REMOVE MECHANICAL, PLUMBING, ELECTRICAL

EQUIPMENT AND ASSOCIATED DEVICES PER DISIPLINE

DEMOLITION SHEETS.

EXISTING STRUCTURAL COMPONENTS ARE TO REMAIN IN

PLACE ALONG WITH EXISTING FACP, UNO.

CONTRACTOR TO REMOVE EXISTING LIFT SYSTEMS

CAREFULLY AND STORED AND INVENTORIED OFF SITE

FOR REUSE IN NEW CONSTRUCTION.

1.

2.

3.

4.

5.

6.

7.

8.

9.

KEY NOTES:

DASHED LINE INDICATES EXTEND OF EXISTING

CONCRETE SLAB DEMOLITION.

DEMOLISH EXISTING PLASTIC LAMINATED CLOSETS, TYP.

DEMOLISH EXISTING WINDOW AND RETAIN BLOCKING.

DEMOLISH EXTERIOR WINDOW AND BLOCKING.

SAWCUT AND REMOVE BLOCK FOR NEW WINDOW

OPENING. COORDINATE LOCATIONS WITH NEW WORK.

DEMOLISH EXISTING WINDOW AND PORTION OF EXISTING

WALL TO ALLOW FOR 4'-0" x 7'-0" DOOR INSTALLATION, SEE DOOR SCHEDULE.

DEMOLISH EXISTING ALUMINUM CURTAIN WALL SYSTEM

WITH GLASS DOOR AND SIDE LITES.

DEMOLISH WALLS AND CEILINGS OF TELECOM ROOM.

PRESERVE CABLES, SWITCHES AND PATCH PANELS. SEE

TELECOM DRAWINGS FOR DETAILS AND ADDITIONAL

INFORMATION.

1D

2D

3D

4D

5D

6D

7D

8D

B

G

H

2D

2D

3D

3D

4D4D4D5D

4D

5D

4D

5D

5D

4D

5D

4D3D

4D

3D

4D

4D

4D

4D

3D

3D

4D

6D

4D

7D

1D

8D

1D

1D

DEMOLITION LEGEND:

WALLS TO BE DEMOLISHED

DOORS TO BE DEMOLISHED

WINDOWS TO BE DEMOLISHED

REMOVE ALL EXISTING CEILING FIXTURES,

EXISTING GYPSUM BOARD CEILING AND

ASSOCIATED FRAMING COMPONENTS.

NOT IN SCOPE.

NORTH WING - LIMIT WORK TO UTILITIES

FOR SUPPORT AND CONNECTIONS ALONG

WITH SUSPENDED CEILING REMOVAL AND

REPLACEMENT.

EAST WING - LIMIT WORK ON EXTERIOR

WALLS AND DOORS TO PROVIDE TWO

EGRESS DOORS, AND COMM/ELECTRICAL

ROOMS.

TNN

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

7/ 5/

0:

:3

A

M

AD102

DEMOLITION FLOOR PLAN - WEST

WING

APRIL 2023 BAJ LMF

38 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

8'0 4' 16'

SCALE:1/8"=1'-0"

SCALE: 1/8" = 1'-0"

DEMOLITION PLAN - WEST WING (DEDUCT)1

REVISIONS DATE

201761

T

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

A B C D E F

H

J

PENTHOUSE

STAIR

1D

2D

3D

KEY NOTES:

DEMOLISH EXISTING CHILLER AND PIPING PER

MECHANICAL DEMOLITION PLANS.

DEMOLISH EXISTING CHILLER SUPPORT RAILS AS

REQUIRED FOR INSTALLATION OF NEW CHILLER. SEE

MECHANICAL DEMO DRAWINGS.

SEE MECHANICAL DRAWINGS ON SHEET MP104 FOR

DEMO REQUIREMENTS TO WALLS AND CONTINUATION OF

PIPING.

1D.

2D.

3D.

WORK TO BE COMPLETED IN COMPLIANCE WITH APPLICABLE

CODES AND TO THE SATISFACTION OF THE COR.

PROTECT EXISTING CONSTRUCTION TO REMAIN FROM

CONSTRUCTION ACTIVITIES.

EXAMINE AND VERIFY DIMENSIONS AND EXISTING CONDITIONS

BOTH ON PLAN AND IN THE FIELD PRIOR TO COMMENCEMENT

OF CONSTRUCTION. VERIFY WHETHER FIELD DIMENSIONS

WILL TAKE PRECEDENCE OVER DRAWING DIMENSIONS. DO

NOT SCALE FROM DRAWINGS.

COORDINATE THE REMOVAL AND/OR RELOCATION OF

FIXTURES, EQUIPMENT, AND OTHER APPURTENANCES WITH

COR. CONTRACTOR IS NOT REQUIRED TO PROVIDE MOVING OR

RELOCATION OF RESIDENT SERVICES. THE WEST WING WILL

BE VACATED BY GOVERNMENT PRIOR TO THE START OF

WORK.

THE CONTRACTOR WILL BE RESPONSIBLE FOR REMOVING

STORING ITEMS OFFSITE AND EQUIPMENT PRIOR TO

COMMENCEMENT OF WORK. ITEMS TO BE REMOVED WILL BE

IDENTIFIED BY THE COR PRIOR TO START OF CONSTRUCTION.

PATCH, REPAIR, REPLACE, AND REPAINT AREAS OF EXISTING

CONSTRUCTION AFFECTED BY DEMOLITION TO NEW

CONDITION. MATCH THE EXISTING ADJACENT CONSTRUCTION

AND MATERIAL TO GREATEST EXTENT POSSIBLE, INCLUDING

BUT NOT LIMITED TO: FLOORS, WALLS, AND CEILINGS.

REMOVE MECHANICAL, PLUMBING, ELECTRICAL EQUIPMENT

AND ASSOCIATED DEVICES PER DISIPLINE DEMOLITION

SHEETS.

EXISTING STRUCTURAL COMPONENTS ARE TO REMAIN IN

PLACE ALONG WITH EXISTING FACP, UNO.

1.

2.

3.

4.

5.

6.

7.

8.

DEMOLITION SHEET NOTES:

TN N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

7/ 5/

0:

:3

A

M

AD104

DEMOLITION FLOOR PLAN -

PENTHOUSE

APRIL 2023 BAJ RJF

39 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

SCALE: 1/8" = 1'-0"

DEMOLITION FLOOR PLAN - PENTHOUSE1

32'8'

SCALE:1/16"=1'-0"

0 16'

REVISIONS DATE

201761

T

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

T

3 APRIL 2023

A B C D E F

G

H

J

K

L

M

N

EXP

EXP

EXP

EXP

NOT IN SCOPE

LEGEND:

SUSPENDED ACOUSTICAL TILE

CEILINGS TO BE REMOVED

GYPSUM BOARD CEILING TO BE

REMOVED

EXPOSED TO STRUCTURE EXP

AREA OF GYPSUM BOARD CEILING

REMOVAL SEE ARCHITECTURAL CEILING

PLAN.

NORTH WING - LIMIT WORK TO UTILITIES FOR

SUPPORT AND CONNECTIONS ALONG WITH

SUSPENDED CEILING REMOVAL AND

REPLACEMENT.

EAST WING - LIMIT WORK ON EXTERIOR

WALLS AND DOORS TO PROVIDE TWO

EGRESS DOORS, AND COMM/ELECTRICAL

ROOMS.

RCP DEMOLITION SHEET NOTES:

WORK WILL BE IN COMPLIANCE WITH APPLICABLE CODES AND

TO THE SASTIFACTION OF THE COR.

PROTECT EXISTING CONSTRUCTION FROM DEMOLITION

ACTIVITIES.

COORDINATE THE REMOVAL AND/OR RELOCATION OF FIXTURES,

EQUIPMENT AND OTHER APPURTENANCES WITH THE COR.

THE GOVERNMENT WILL BE RESPONSIBLE FOR REMOVING

STORED ITEMS AND EQUIPMENT PRIOR TO COMMENCEMENT OF

WORK.

PATCH, REPAIR, REPLACE, AND REPAINT AREAS OF EXISTING

CONSTRUCTION AFFECTED BY CONSTRUCTION ACTIVITIES TO

NEW CONDITION. MATCH EXISTING ADJACENT CONSTRUCTION,

MATERIALS, AND FINISHES TO GREATEST EXTENT POSSIBLE.

DEMOLISH EXISTING PRIVACY CURTAIN TRACKS AND CURTAIN

INSTALLED ON EXISTING CEILINGS.

1.

2.

3.

4.

5.

6.

TN N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

4/ 3/

:3

5:

P M

AD110

DEMOLITION REFLECTED CEILING

PLAN DEMOLITION - OVERALL

APRIL 2023 BAJ LMF

40 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

SCALE: 1/16" = 1'-0"

DEMOLITION REFLECTED CEILING PLAN - OVERALL1

32'8'

SCALE:1/16"=1'-0"

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

T

3 APRIL 2023

FLOOR PLAN SHEET NOTES:

THE USGS FINISHED FLOOR ELEVATION FOR THIS

PROJECT = 1897.82' ON CIVIL DRAWINGS, WHICH EQUALS

THE ARCHITECTURAL REFERENCE / DATUM FOR THE

FINISH FLOOR ELEVATION AT 100'-0".

NOTIFY THE VETERANS AFFAIRS COR OF DISCREPANCIES

IN THE CONTRACT DOCUMENTS BEFORE PROCEEDING

WITH WORK.

FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS

PRIOR TO ORDERING OR INSTALLING MATERIALS OR

EQUIPMENT.

INTERIOR DIMENSIONS ARE TO FACE OF STUD UNLESS

NOTED OTHERWISE.

REFER TO PARTITION TYPE SCHEDULE FOR INTERIOR

WALL CONSTRUCTION.

REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION

PLANS AND DETAILS.

LOCATE INTERIOR DOOR FRAMES 4 INCHES FROM FINISH

FACE OF ADJACENT PARTITION AT HINGE SIDE, TYP UNO.

INTERIOR PARTITIONS AND DOORS ARE IDENTIFIED ON

ENLARGED FLOOR PLANS.

EXTERIOR DIMENSIONS ARE TAKEN TO THE FACE OF THE

CONCRETE FOUNDATION ON THE SOUTH WING.

DIMENSIONS SHOWN AT THE EXISTING BUILDING ARE

TAKEN TO THE FACE OF CMU WHICH IS ALSO THE FACE

OF THE CONCRETE FOUNDATION.

1.

2.

3.

4.

5.

6.

7.

8.

9.

AE201

AE201

2 2

5 5

6 6

7 7

A B C D E F

G

H

J

K

L

M

N

AE303

AE302

AE302

AE201

AE201

AE201

AE201

B.1 C.7 F.1

69' - 3"

39' - 0"

30' - 3"

9' - 0 1/2"

21' - 11"

30' - 11 1/2"

31' - 1 5/8"

125' - 0"

45.00° 12' - 1 1/2" 38' - 7 1/2" 48' - 5" 25' - 10"

/8

45.00°

13' - 8"

20' - 6"

20' - 6"

24' - 0"

7' - 0"

40' - 3"

2' - 0"

72' - 11 3/4"

4' - 8 1/4"

8'

/2

4'

1'

1"

/2

53' - 7"

2'

1/ 2"

/8

AE105

AE102

22' - 9"

25' - 6"FEC

F E

C

FEC

FEC

FEC

FEC

AE401

AE20

AE20

AE202

AE202

AE202

AE20

AE202

AE202

NOT IN SCOPE.

NORTH WING - LIMIT WORK TO UTILITIES FOR

SUPPORT AND CONNECTIONS ALONG WITH

SUSPENDED CEILING REMOVAL AND

REPLACEMENT.

EAST WING - LIMIT WORK ON EXTERIOR WALLS

AND DOORS TO PROVIDE TWO EGRESS DOORS,

AND COMM/ELECTRICAL ROOMS.

AREA OF NEW CEILINGS AND CEILING

FIXTURES (NORTH WING)

LEGEND:

TN N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

4/ 3/

:3

6:

P M

AE100

FLOOR PLAN - OVERALL

APRIL 2023 BAJ RJF

41 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

32'8'

SCALE:1/16"=1'-0"

0 16'

SCALE: 1/16" = 1'-0"

FLOOR PLAN - OVERALL1

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

T

3 APRIL 2023

KEY NOTES:

INFILL DOOR OPENING TO MATCH EXISTING WALL

ASSEMBLY.

3" EXPANSION JOINT (FROM EXISTING CMU WALL TO NEW

STUD WALL), 1/2" EXPANSION JOINT MATERIAL AT

CONCRETE SLAB.

TELECOM BACKBOARDS MUST BE FIRE-RETARDANT

TREATED PLYWOOD (SURFACE MOUNTED

BACKBOARD),COATED WITH FIRE-RETARDANT PAINT, SEE

TELECOM DRAWINGS.

INFILL WINDOW OPENING WITH 8" CMU. PROVIDE RIGID

INSULATION, ADHERED TO BLOCK, FLUSH WITH THE

SURROUNDING EXTERIOR WALL FINISH.

PROVIDE 2" EIFS SYSTEM OVER EXISTING 1" EIFS.

DASHED LINE REPRESENTS SOFFIT ABOVE TO RECEIVE

NEW EIFS FINISH COAT OVER EXISTING EIFS SYSTEM.

NOT USED THIS SHEET.

EXISTING EIFS COLUMN CLADDING TO RECEIVE NEW EIFS

FINISH COAT OVER EXISTING EIFS SYSTEM.

EXISTING EIFS TO RECEIVE NEW EIFS FINISH COAT.

1.

2.

3.

4.

5.

6.

7.

8.

9.

FLOOR PLAN SHEET NOTES:

THE USGS FINISHED FLOOR ELEVATION FOR THIS

PROJECT = 1897.82' ON CIVIL DRAWINGS, WHICH EQUALS

THE ARCHITECTURAL REFERENCE / DATUM FOR THE

FINISH FLOOR ELEVATION AT 100'-0".

NOTIFY THE VETERANS AFFAIRS COR OF DISCREPANCIES

IN THE CONTRACT DOCUMENTS BEFORE PROCEEDING

WITH WORK.

FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS

PRIOR TO ORDERING OR INSTALLING MATERIALS OR

EQUIPMENT.

INTERIOR DIMENSIONS ARE TO FACE OF STUD UNLESS

NOTED OTHERWISE.

REFER TO PARTITION TYPE SCHEDULE FOR INTERIOR

WALL CONSTRUCTION.

REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION

PLANS AND DETAILS.

LOCATE INTERIOR DOOR FRAMES 4 INCHES FROM FINISH

FACE OF ADJACENT PARTITION AT HINGE SIDE, TYP UNO.

INTERIOR PARTITIONS AND DOORS ARE IDENTIFIED ON

ENLARGED FLOOR PLANS.

EXTERIOR DIMENSIONS ARE TAKEN TO THE FACE OF THE

CONCRETE FOUNDATION ON THE SOUTH WING.

DIMENSIONS SHOWN AT THE EXISTING BUILDING ARE

TAKEN TO THE FACE OF CMU WHICH IS ALSO THE FACE

OF THE CONCRETE FOUNDATION.

1.

2.

3.

4.

5.

6.

7.

8.

9.

1011121314 B

G

H

RESIDENT

BEDROOM

W101

CLEAN LINEN

W102

SOILED LINEN

W103

RESIDENT

BEDROOM

W104

RESIDENT

BEDROOM

W105

RESIDENT

BEDROOM

W106

RESIDENT

BARIATRIC

BEDROOM

W107

FAMILY

W108

RESIDENT

BEDROOM

W109

RESIDENT

BEDROOM

W110

RESIDENT

BEDROOM

W113

TELECOM

W115

RESIDENT

BEDROOM

W117

RESIDENT

BEDROOM

W118

CORRIDOR

W001

CORR

W002

RESIDENT

BATHROOM

W105A

RESIDENT

BATHROOM

W104A

AE303

RESIDENT

BATHROOM

W101A

RESIDENT

BARIATRIC

BATHROOM

W107A

RESIDENT

BATHROOM

W106A

RESIDENT

BATHROOM

W109A

RESIDENT

BATHROOM

W110A

RESIDENT

BATHROOM

W118A

RESIDENT

BATHROOM

W117A

RESIDENT

BATHROOM

W116A

RESIDENT

BATHROOM

W114A

RESIDENT

BATHROOM

W113A

6 6

9 5

44 44

4 4

4 4 4 4

20' - 6"20' - 6"13' - 8"25' - 6"

CMU/STUD

9' - 7 5/8"

STUD/CMU

21' - 4 3/8" 7' - 0" 15' - 9"

9'

/2

AE402

AE402

AE402

AA A

A A

A

A A A

A A A

AE501

W116

RESIDENT

BEDROOM

W114

RESIDENT

BEDROOM

AE504

164B

W112

NOT IN SCOPE.

AREA OF NEW CEILINGS AND CEILING

FIXTURES (NORTH WING)

LEGEND:

NORTH WING - LIMIT WORK TO UTILITIES FOR

SUPPORT AND CONNECTIONS ALONG WITH

SUSPENDED CEILING REMOVAL AND

REPLACEMENT.

EAST WING - LIMIT WORK ON EXTERIOR

WALLS AND DOORS TO PROVIDE TWO

EGRESS DOORS, AND COMM/ELECTRICAL

ROOMS.

TNN

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

4/ 3/

:3

6:

P M

AE102

FLOOR PLAN - WEST WING

APRIL 2023 BAJ RJF

42 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

SCALE: 1/8" = 1'-0"

FLOOR PLAN - WEST WING1

8'0 4' 16'

SCALE:1/8"=1'-0"

REVISIONS DATE

TNN

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

4/ 3/

:3

6:

P M

AE102

FLOOR PLAN - WEST WING

APRIL 2023 BAJ RJF

42 183

DAVID ARMENT

509-964-1889

David.Arment@va.govREVISIONS DATE

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

T

3 APRIL 2023

A B C D E F

H

J

PENTHOUSE

STAIR

FLOOR PLAN SHEET NOTES:

THE USGS FINISHED FLOOR ELEVATION FOR THIS

PROJECT = 1894.39' ON CIVIL DRAWINGS, WHICH EQUALS

THE ARCHITECTURAL REFERENCE / DATUM FOR THE

FINISH FLOOR ELEVATION AT 100'-0".

NOTIFY THE VETERANS AFFAIRS COR OF ANY

DISCREPANCIES IN THE CONTRACT DOCUMENTS BEFORE

PROCEEDING WITH ANY WORK.

FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS

PRIOR TO ORDERING OR INSTALLING ANY MATERIALS OR

EQUIPMENT.

INTERIOR DIMENSIONS TO FACE OF STUD UNLESS NOTED

OTHERWISE.

REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR

FURTHER INFORMATION REGARDING PENTHOUSE.

1.

2.

3.

4.

5.

KEY NOTES:

MECHANICAL CHILLER, SEE MECHANICAL DRAWINGS.

DASHED LINE REPRESENTS WALL LINE BELOW GRADE.

NIC

EXISTING STEEL ROOF STRUCTURE.

EXISTING EXTERIOR WALL.

EXISTING METAL ROOF (BELOW).

EXISTING CONCRETE WALL.

ENTRY CANOPY (BELOW).

1.

2.

3.

4.

5.

6.

7.

8.

TN N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

4/ 3/

:3

6:

P M

AE104

FLOOR PLAN - PENTHOUSE

APRIL 2023 BAJ RJF

43 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

8'0 4' 16'

SCALE:1/8"=1'-0"

SCALE: 1/8" = 1'-0"

FLOOR PLAN - PENTHOUSE1

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

T

3 APRIL 2023

FLOOR PLAN SHEET NOTES:

THE USGS FINISHED FLOOR ELEVATION FOR THIS

PROJECT = 1897.82' ON CIVIL DRAWINGS, WHICH EQUALS

THE ARCHITECTURAL REFERENCE / DATUM FOR THE

FINISH FLOOR ELEVATION AT 100'-0".

NOTIFY THE VETERANS AFFAIRS COR OF DISCREPANCIES

IN THE CONTRACT DOCUMENTS BEFORE PROCEEDING

WITH WORK.

FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS

PRIOR TO ORDERING OR INSTALLING MATERIALS OR

EQUIPMENT.

INTERIOR DIMENSIONS ARE TO FACE OF STUD UNLESS

NOTED OTHERWISE.

REFER TO PARTITION TYPE SCHEDULE FOR INTERIOR

WALL CONSTRUCTION.

REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION

PLANS AND DETAILS.

LOCATE INTERIOR DOOR FRAMES 4 INCHES FROM FINISH

FACE OF ADJACENT PARTITION AT HINGE SIDE, TYP UNO.

INTERIOR PARTITIONS AND DOORS ARE IDENTIFIED ON

ENLARGED FLOOR PLANS.

EXTERIOR DIMENSIONS ARE TAKEN TO THE FACE OF THE

CONCRETE FOUNDATION ON THE SOUTH WING.

DIMENSIONS SHOWN AT THE EXISTING BUILDING ARE

TAKEN TO THE FACE OF CMU WHICH IS ALSO THE FACE

OF THE CONCRETE FOUNDATION.

1.

2.

3.

4.

5.

6.

7.

8.

9.

RESIDENT

BEDROOM

S101

HAC

S102

ELECTRICAL

ROOM

S103

RESIDENT

BEDROOM

S104

RESIDENT

BEDROOM

S105

RESIDENT

BARIATRIC

BEDROOM

S106

RESIDENT

BEDROOM

S107

RESIDENT

BEDROOM

S108

RESIDENT

BEDROOM

S109RESIDENT

BEDROOM

S110

RESIDENT

BEDROOM

S111

MECHANICAL

ROOM

S112

TELECOM

S11

NURSE STATION

S116 RESIDENT

BEDROOM

S117

RESIDENT

BEDROOM

S118

RESIDENT

BEDROOM

S119

RESIDENT

BEDROOM

S120

DINING ROOM

S121

RESIDENT

BEDROOM

S122

CORR

S001

CORRIDOR

S002

CORR

S005

RESIDENT

BATHROOM

S101A

RESIDENT

BATHROOM

S120A

RESIDENT

BATHROOM

S119A

RESIDENT

BATHROOM

S118A

RESIDENT

BATHROOM

S117A

RESIDENT

BATHROOM

S104A

RESIDENT

BARIATRIC

BATHROOM

S106A

RESIDENT

BATHROOM

S107A

RESIDENT

BATHROOM

S108A

RESIDENT

BATHROOM

S109A

RESIDENT

BATHROOM

S110A

RESIDENT

BATHROOM

S111A

AE302

AE303

AE302

AE3021

AE303

AE301

AE301

AE302

UNISEX

BATHROOM

S121A

RESIDENT

BATHROOM

S122A

B.1

B.1 C.7

C.7 F.1

F.1

9' - 0 1/2"

21' - 11"

6' - 10 1/2"

15' - 0 1/2"

31' - 1 3/4"

125' - 0"

22' - 6 3/4"

8' - 7" 45.00°

15' - 5 1/4" 22' - 3 1/2" 12' - 10 1/2" 22' - 6 1/8" 12' - 10 7/8" 22' - 5 1/2" 12' - 10 7/8" 3' - 7 3/8"

38' - 7 1/2" 48' - 5" 25' - 10"

45.00° 14

/4

9'

- 6

/4

0"

31' - 0 7/8"

17' - 6 1/8" 38' - 7 1/2" 50' - 9 3/4"

12' - 1 1/2"

0"

8'

- 1

1/

2"

FOS/GRID

1 7/8"

FOS/GRID

1 7/8"

9' - 0 1/2"

2' - 4 7/8"

ENTRY

VESTIB

ULE

S11

CORR

S11

AE404

AE405

/2

RESIDENT

BATHROOM

S105A

AE406

AE406

OPP TYP.

TYPE B

AE406

2 TYP.

TYPE A

A

5'

- 0

12TYP.

TYPE C

ANTE ROOM

S004

C C C C C C C

C

C

C

C

CCCCC

C

VOID

S003

CORR

KEY NOTES:

NOT USED

3" EXPANSION JOINT (FROM EXISTING CMU WALL TO NEW

STUD WALL), 1/2" EXPANSION JOINT MATERIAL AT

CONCRETE SLAB.

TELECOM BACKBOARD MUST BE FIRE-RETARDANT

TREATED PLYWOOD (SURFACE MOUNTED BACKBOARD),

COATED WITH FIRE-RETARDANT PAINT, SEE TELECOM

DRAWINGS.

NOT USED.

NOT USED.

NOT USED.

DASHED LINE REPRESENTS NEW SOFFIT ABOVE.

NOT USED

NOT USED.

NOT USED.

NOT USED.

WALL BRACING, SEE STRUCTURAL DRAWINGS

DEMOUNTABLE PARTITION. SLIDING DOOR AND

HARDWARE BY PARTITION MFR.

LOCKABLE CHAIN LINK ENCLOSURE FOR STORAGE OF

ANTE ROOM DOORS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

NOT IN SCOPE.

LEGEND:

EAST WING - LIMIT WORK ON EXTERIOR

WALLS AND DOORS TO PROVIDE TWO

EGRESS DOORS, AND COMM/ELECTRICAL

ROOMS.

TN N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

4/ 3/

:3

6:

P M

AE105

FLOOR PLAN - SOUTH WING

APRIL 2023 BAJ RJF

44 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

SCALE: 1/8" = 1'-0"

FLOOR PLAN - SOUTH WING1

8'0 4' 16'

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

T

3 APRIL 2023

RCP SHEET NOTES:

CENTER CEILING GRIDS WITHIN THE ROOM, UNLESS

OTHERWISE INDICATED ON PLAN.

MECHANICAL DEVICES SHOWN FOR LOCATION IN ROOMS. SEE

MECHANICAL SHEETS FOR SPECIFICATIONS AND FURTHER

DETAILS.

SEE ROOM FINISH SCHEDULE FOR ROOM CEILING HEIGHTS.

REFER TO ELECTRICAL LIGHTING PLANS FOR ADDITIONAL

INFORMATION. THE ARCHITECTURAL REFLECTED CEILING PLAN

GOVERNS THE LAYOUT OF CEILING ELEMENTS AND

PENETRATIONS.

OPEN CEILINGS WITHIN THE MECHANICAL ROOM, IT AND

ELECTRICAL ROOM SPACES EXTEND TO THE UNDERSIDE OF

THE METAL DECK ABOVE. EXPOSED SURFACES TO BE PAINTED

TO MATCH CEILING PAINT.

PROVIDE PRIVACY CURTAIN IN EACH PATIENT’S ROOM TO

ENSURE PATIENT VISUAL PRIVACY FROM THE ROOM ENTRY

DOOR DURING EXAMINATION, TREATMENT, OR WHILE CHANGING

IN REFERENCE TO VA DESIGN ALERT 149 (DESIGN FOR PATIENT

PRIVACY AND WOMEN VETERANS HEALTH, OCTOBER 2018).

PAINT (P-6) ALL HARD CEILINGS UNO.

1.

2.

3.

4.

5.

6.

7.

A B C D E F

G

H

J

K

L

M

N

AE112

AE114

AE113

B.1 C.7 F.1

LEGEND:

SUSPENDED ACOUSTICAL TILE

CEILINGS IN 24" X 24" PATTERN.

GENERALLY CENTER GRID ON

ROOM.

GYPSUM BOARD CEILING

EXPOSED TO STRUCTURE

EXP

PRIVACY CURTAIN

PATIENT LIFT TRACK

ACCESS PANEL

NORTH WING - LIMIT WORK TO UTILITIES FOR

SUPPORT AND CONNECTIONS ALONG WITH

SUSPENDED CEILING REMOVAL AND

REPLACEMENT.

EAST WING - LIMIT WORK ON EXTERIOR

WALLS AND DOORS TO PROVIDE TWO

EGRESS DOORS, AND COMM/ELECTRICAL

ROOMS.

AREA OF LIMITED NEW WORK. SEE

ARCHITECTURAL CEILING PLAN.

NOT IN SCOPE

TN N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

4/ 3/

:3

6:

P M

AE110

REFLECTED CEILING PLAN - OVERALL

APRIL 2023 BAJ LMF

45 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

32'8'

SCALE:1/16"=1'-0"

0 16'

SCALE: 1/16" = 1'-0"

REFLECTED CEILING PLAN - OVERALL1

8 1011121314

B

G G

H

W002

W001 W102

W101

W105

W105A

W104A

W104

W001

W106 W107AW106A W107

W108

W109

W101A

W103

W118 W117AW118A W117

W115

W116A W113A W114A

W113

W002

AE507

EXP

EXP

EXP

EXP. JT.

164A

C1-10

W110

W109A

W110A

164B

RCP SHEET NOTES:

CENTER CEILING GRIDS WITHIN THE ROOM, UNLESS

OTHERWISE INDICATED ON PLAN.

MECHANICAL DEVICES SHOWN FOR LOCATION IN ROOMS. SEE

MECHANICAL SHEETS FOR SPECIFICATIONS AND FURTHER

DETAILS.

SEE ROOM FINISH SCHEDULE FOR ROOM CEILING HEIGHTS.

REFER TO ELECTRICAL LIGHTING PLANS FOR ADDITIONAL

INFORMATION. THE ARCHITECTURAL REFLECTED CEILING PLAN

GOVERNS THE LAYOUT OF CEILING ELEMENTS AND

PENETRATIONS.

OPEN CEILINGS WITHIN THE MECHANICAL ROOM, IT AND

ELECTRICAL ROOM SPACES EXTEND TO THE UNDERSIDE OF

THE METAL DECK ABOVE. EXPOSED SURFACES TO BE PAINTED

TO MATCH CEILING PAINT.

PROVIDE PRIVACY CURTAIN IN EACH PATIENT’S ROOM TO

ENSURE PATIENT VISUAL PRIVACY FROM THE ROOM ENTRY

DOOR DURING EXAMINATION, TREATMENT, OR WHILE CHANGING

IN REFERENCE TO VA DESIGN ALERT 149 (DESIGN FOR PATIENT

PRIVACY AND WOMEN VETERANS HEALTH, OCTOBER 2018).

PAINT (P-6) ALL HARD CEILINGS UNO.

1.

2.

3.

4.

5.

6.

7.

EXISTING TO REMAIN - NIC

LEGEND:

SUSPENDED ACOUSTICAL TILE

CEILINGS IN 24" X 24" PATTERN.

GENERALLY CENTER GRID ON

ROOM.

GYPSUM BOARD CEILING

EXPOSED TO STRUCTURE EXP

PRIVACY CURTAIN

PATIENT LIFT TRACK

DOWNLIGHT - SEE ELECTRICAL

EXIT LIGHT - SEE ELECTRICAL

PENDANT FIXTURE - SEE ELECTRICAL

2 X 2 RECESSED LIGHTING FIXTURE -

SEE ELECTRICAL

2 X 2 EMERGENCY RECESSED LIGHTING

FIXTURE - SEE ELECTRICAL

CEILING MOUNTED SPEAKER - SEE

TELECOM

SUPPLY AIR - SEE MECHANICAL

RETURN AIR - SEE MECHANICAL

EXHAUST AIR - SEE MECHANICAL

2' x 2' CEILING ACCESS PANEL

REINSTALL SUSPENDED

ACOUSTICAL TILE CEILING, 24" X 48"

PATTERN. CENTER GRID ON

CORRRIDOR.

AREA OF NEW SUSPENDED

ACOUSTICAL CEILING AND CEILING

FIXTURES.

NORTH WING - LIMIT WORK TO UTILITIES FOR

SUPPORT AND CONNECTIONS ALONG WITH

SUSPENDED CEILING REMOVAL AND

REPLACEMENT.

TN

N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

7/ 5/

0:

:3

A

M

AE112

REFLECTED CEILING PLAN - WEST

WING

APRIL 2023 BAJ LMF

46 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - WEST WING1

REVISIONS DATE

201761

T

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

A B C D E F

G

H

J

C1-7

C1-7

C1-5

C1-5

EXP

ELECTRICAL ROOM

TELECOM ROOM

MECH ROOM

C1-4

109A

109C

109D

109E

115A 115B 115

114A

122119

C1

119A

1C1-1

164A

C1-10

C1-11

119B 124

122A

W110

W109A

W110A

164B

RCP SHEET NOTES:

CENTER CEILING GRIDS WITHIN THE ROOM, UNLESS

OTHERWISE INDICATED ON PLAN.

MECHANICAL DEVICES SHOWN FOR LOCATION IN ROOMS. SEE

MECHANICAL SHEETS FOR SPECIFICATIONS AND FURTHER

DETAILS.

SEE ROOM FINISH SCHEDULE FOR ROOM CEILING HEIGHTS.

REFER TO ELECTRICAL LIGHTING PLANS FOR ADDITIONAL

INFORMATION. THE ARCHITECTURAL REFLECTED CEILING PLAN

GOVERNS THE LAYOUT OF CEILING ELEMENTS AND

PENETRATIONS.

OPEN CEILINGS WITHIN THE MECHANICAL ROOM, IT AND

ELECTRICAL ROOM SPACES EXTEND TO THE UNDERSIDE OF

THE METAL DECK ABOVE. EXPOSED SURFACES TO BE PAINTED

TO MATCH CEILING PAINT.

PROVIDE PRIVACY CURTAIN IN EACH PATIENT’S ROOM TO

ENSURE PATIENT VISUAL PRIVACY FROM THE ROOM ENTRY

DOOR DURING EXAMINATION, TREATMENT, OR WHILE CHANGING

IN REFERENCE TO VA DESIGN ALERT 149 (DESIGN FOR PATIENT

PRIVACY AND WOMEN VETERANS HEALTH, OCTOBER 2018).

PAINT (P-6) ALL HARD CEILINGS UNO.

1.

2.

3.

4.

5.

6.

7.

KEY NOTES:#

REINSTALL EXISTING CEILING GRID AND LIGHT FIXTURES UPON

COMPLETION OF WORK THIS AREA. SEE MECHANICAL AND

ELECTRICAL DRAWINGS.

SEE ELECTRICAL DRAWINGS FOR NEW LIGHT FIXTURES.

1.

2.

EXISTING TO REMAIN - NIC

LEGEND:

2' x 2' SUSPENDED GRID CEILING

WITH 5/8" ACOUSTICAL TILE.

GYPSUM BOARD CEILING

EXPOSED TO STRUCTURE EXP

PRIVACY CURTAIN

PATIENT LIFT TRACK

DOWNLIGHT - SEE ELECTRICAL

EXIT LIGHT - SEE ELECTRICAL

PENDANT FIXTURE - SEE ELECTRICAL

2 X 2 RECESSED LIGHTING FIXTURE -

SEE ELECTRICAL

2 X 2 EMERGENCY RECESSED LIGHTING

FIXTURE - SEE ELECTRICAL

2 X 4 RECESSED LIGHTING FIXTURE -

SEE ELECTRICAL.

CEILING MOUNTED SPEAKER - SEE

TELECOM

SUPPLY AIR - SEE MECHANICAL

RETURN AIR - SEE MECHANICAL

EXHAUST AIR - SEE MECHANICAL

CEILING ACCESS PANEL

2' X 4' SUSPENDED GRID CEILING

WITH 5/8" ACOUSTICAL TILE.

LIMITED WORK TO UTILITIES FOR SUPPORT

AND CONNECTIONS (ALONG WITH SUSPENDED

CEILING REMOVAL AND REPLACEMENT IN

NORTH WING LOCATIONS).

SUSPENDED CEILING REINSTALLTION

(IN NORTH WING LOCATIONS ONLY).

TN N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

7/ 5/

0:

:4

A

M

AE113

REFLECTED CEILING PLAN - NORTH

WING

APRIL 2023 BAJ LMF

47 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - NORTH WING1

NO CEILING WORK NO CEILING

WORK

REVISIONS DATE

8'0 4' 16'

SCALE:1/8"=1'-0"

201761

T

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

9 N

S122

S111

S110A

S111A

S116 S117 S117A S118A S118 S119 S119A S120A S120 S121

S110 S109 S108A S109A S108 S107 S106AS107A S106 S105 S104A S104

S102

S101A

S121A

S122A

S002

S002 S101

S001

S103

S005

S112

S113

S114

B.1

B.1 C.7

C.7 F.1

F.1

S004

S003

EXP

EXP

EXP

AE508

AE508

AE508

AE508

AE508

AE505

EXP

EXP. JT.

EXP. JT.

RCP SHEET NOTES:

CENTER CEILING GRIDS WITHIN THE ROOM, UNLESS

OTHERWISE INDICATED ON PLAN.

MECHANICAL DEVICES SHOWN FOR LOCATION IN ROOMS. SEE

MECHANICAL SHEETS FOR SPECIFICATIONS AND FURTHER

DETAILS.

SEE ROOM FINISH SCHEDULE FOR ROOM CEILING HEIGHTS.

REFER TO ELECTRICAL LIGHTING PLANS FOR ADDITIONAL

INFORMATION. THE ARCHITECTURAL REFLECTED CEILING PLAN

GOVERNS THE LAYOUT OF CEILING ELEMENTS AND

PENETRATIONS.

OPEN CEILINGS WITHIN THE MECHANICAL ROOM, IT AND

ELECTRICAL ROOM SPACES EXTEND TO THE UNDERSIDE OF

THE METAL DECK ABOVE. EXPOSED SURFACES TO BE PAINTED

TO MATCH CEILING PAINT.

PROVIDE PRIVACY CURTAIN IN EACH PATIENT’S ROOM TO

ENSURE PATIENT VISUAL PRIVACY FROM THE ROOM ENTRY

DOOR DURING EXAMINATION, TREATMENT, OR WHILE CHANGING

IN REFERENCE TO VA DESIGN ALERT 149 (DESIGN FOR PATIENT

PRIVACY AND WOMEN VETERANS HEALTH, OCTOBER 2018).

PAINT (P-6) ALL HARD CEILINGS UNO.

1.

2.

3.

4.

5.

6.

7.

EXISTING TO REMAIN - NIC

LEGEND:

SUSPENDED ACOUSTICAL TILE

CEILINGS IN 24" X 24" PATTERN.

GENERALLY CENTER GRID ON

ROOM.

GYPSUM BOARD CEILING

EXPOSED TO STRUCTURE EXP

PRIVACY CURTAIN

PATIENT LIFT TRACK

DOWNLIGHT - SEE ELECTRICAL

EXIT LIGHT - SEE ELECTRICAL

PENDANT FIXTURE - SEE ELECTRICAL

2 X 2 RECESSED LIGHTING FIXTURE -

SEE ELECTRICAL

2 X 2 EMERGENCY RECESSED LIGHTING

FIXTURE - SEE ELECTRICAL

CEILING MOUNTED SPEAKER - SEE

TELECOM

SUPPLY AIR - SEE MECHANICAL

RETURN AIR - SEE MECHANICAL

EXHAUST AIR - SEE MECHANICAL

2' x 2' CEILING ACCESS PANEL

EAST WING - LIMIT WORK ON EXTERIOR WALLS

AND DOORS TO PROVIDE TWO EGRESS

DOORS, AND COMM/ELECTRICAL ROOMS.

TN N

PROJECT NUMBER

BUILDING

DRAWING NUMBER

PROJECT TITLE

LOCATION

ISSUE DATE CHECKED DRAWN

DRAWING TITLE

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHASEARCHITECT/ENGINEER OF RECORD SEALCONSULTANTS

321 4 5 6 7 8 9 10

DWG. OF

NAME:

FULLY SPRINKLERED

CONTRACTING OFFICER'S REPRESENTATIVE

FULL SIZE DWG: 30x42

PHONE:

EMAIL:11031 S. PIKES PEAK DRIVE #102 PARKER, COLORADO 80138 PH. 303.841-3922

RENOVATE AND EXPAND

COMMUNITY LIVING

CENTER (CLC)

SPOKANE, WA

668-318

100% SUBMITTAL

CONSTRUCTION

DOCUMENTS (CD)

NORTH

SOUTH

WEST EAST

BLDG. 1

7/ 5/

0:

:5

A

M

AE114

REFLECTED CEILING PLAN - SOUTH

WING

APRIL 2023 BAJ LMF

48 183

DAVID ARMENT

509-964-1889

David.Arment@va.gov

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN - SOUTH WING1

8'0 4' 16'

SCALE:1/8"=1'-0"

REVISIONS DATE

201761

T

E

NS E D

CI

L

S T

A

FO

E

O

IH

A RC

C

T

E

D

O

COL

RA

BRUCE A.

JONES

SHEET NOTES:

1.

2.

3.

4.

SEE SHEET AE602 FOR ROOM FINISH SCHEDULE AND

AE603 SCHEDULE FOR INTERIOR FINISHES.

INSTALL TRANSITION AT DISSIMILAR FLOOR MATERIALS.

FLOOR TILE TO BE CENTERED IN ROOM UNO.

SEE SHEET AE507 FOR FLOOR TRANSITION DETAILS

1011121314 B

G

H

W101

W102

W103

W104

W105 W106 W107 W108 W109 W110

164B

W113

W115

W117W118

W001 W002

W105A

W104A

W101A

W107A

W106A

W109A

W110A

W118A

W117A

W116A W114A

W113A

8'

9' - 6"2' - 0"

2'

2'

A

A

A

A

A

A

A

A

A

A

A

A

AE507

4'

4' - 0"

4'

4' - 0"

8'

4'

8'

6'

5'

9' - 0"

5' - 6"

5' - 6"

4'

6'

" 5'

4'

7'

2'

W114W116

A

A

FLOORING MATERIAL LEGEND

LVT - LUXURY VINYL TILE FIELD

COLOR

LVT -…