Attachment 3 - ARCHITECTURAL BINDER-1.pdf
PDF 17 MB Posted
- Solicitation number
- 36C77623B0037
About this file
This document provides details for a federal contract opportunity to construct an integrated health center in Murfreesboro, Tennessee. The solicitation number is 36C77623B0037 and is being issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas. The project number is 626-309 and involves constructing an integrated health center to serve veterans. No other details are provided on requirements, response dates, pricing terms, or other contract elements. An attachment is referenced but its content is not listed.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HOLDOPEN
AREA B
AREA A
CORRIDOR TO BLDG 7
A R
E A
B
A R
E A
A
ELECTRICAL
G41
STAIRS
SIM MAINTENANCE
G30G
PROCEDURE SIM LAB
G30F
CONTROL ROOM
G30E
WAITING
G39
MULTI-PURPOSE
G20J
MULTI-PURPOSE
G20F
MULTI-PURPOSE
G20D
MULTI-PURPOSE
G20B
MULTI-PURPOSE
G20
MULTI-PURPOSE
G20H
STOR.
G20C
MED/SURG SIM LAB
G30D KITCHEN/SERVING
G21
EDUC CHIEF
G17A
MUSIC THERAPY CLINIC
G13
WC STORAGE
G12B
REC. THERAPY CLINIC
G08
COMPUTER LAB
G16
STOR.
G20A
STOR.
G20E
STOR
G20G
STOR.
G20I
BARBER CART
G02
FOOD SERVICE CHIEF
G03
FOOD SERVICE VEND SUPPLY
G04
CORRIDOR
G54
CORRIDOR
G52
MUSIC THER. 1
G43
MUSIC THER. 2
G42
CORRIDOR
G45
WORK AREA
G15
ENTRY
G01
CORRIDOR
G46
COURTYARD
G10
CORRIDOR
G48
CORRIDOR
G48A
CORRIDOR
G49
CORRIDOR
G50
CORRIDOR
G51
STORAGE
G20K
PRACTICE ROOM
G13B
MUSIC STORAGE
G13A
ALS CLASSROOM
G30J
TRNG EQUIP STOR
G30C
STAFF LOUNGE
G33
CREATIVE ARTS GROUP
G34
LOBBY
G36
PMRS STORAGE
G31ACCESS STAIR
G26
FEMALE
G24
MALE
G25
LACTATION
G27
HAC
G30I
MALE
G37
FEMALE
G38
MEDIA COORD.
G17B
WORK
G17
PAT. RESOURCE
G40
RT SPVR.
G15A
PMRS CONSULT
G14
HAC
G07 RECREATION
STORAGE
G08B
MALE
G09A
FEMALE
G09C
VENDING
G32
KINESIO GROUP THERAPY
G12
WORK
G12A
KITCHENETTE
G08A
VESTIBULE
G35
SECURITY
G35A
STORAGE
G34A
CORRIDOR
G55
STORAGE
G30K
STORAGE
G30H
DE-BRIEF
G30A
CORRIDOR
G30
CORRIDOR
G30
615 SF
CONNECTOR
G47
CHARGING CART STOR.
G19
WHOLE HEALTH
STORAGE
G18
IT
G23
C O
R R
ID
O
R T
O B
LD
G
ACOUSTIC WOOD PANELS: BASIS
OF DESIGN, ARMSTRONG
WOODWORKS LINEAR VENEERED
PLANKS
REC THERAPY BELOW
STAIR
MULTIPURPOSE ROOM BELOW
HIGH BAY
LIGHT FIXTURE
DOWNLIGHT
DOWNLIGHT
RECESSED
EXIT LIGHT
SINGLE FACE
S
D
SPEAKER
WALL MOUNTED
LIGHT FIXTURE
EXIT LIGHT
DOUBLE FACE
SMOKE DETECTOR
LINEAR LIGHTING
CEILING MATERIAL LEGEND:
CEILING FIXTURES LEGEND:
2x2 LIGHT FIXTURE - RECESSED, SUSPENDED OR SURFACE MOUNTED
2x4 LIGHT FIXTURE - RECESSED, SUSPENDED OR SURFACE MOUNTED
1x4 LIGHT FIXTURE - RECESSED, SUSPENDED OR SURFACE MOUNTED
SUPPLY GRILLE
RETURN GRILLE
EXHAUST GRILLE
GYPSUM
BOARD
2 X 2
ACT
EXPOSED
STRUCTURE
TYP
EQ
TYP
EQ
T Y P
E Q
T Y P
E Q
ACCESS PANEL
T Y P
IC
A L
E Q
U
N O
E Q
TYPICAL
EQ
- UNO
EQ
CEILING FIXTURE MOUNTING:
FOCAL POINT, NIVO SOLID
DIFFUSER, FLUSH
FOCAL POINT, NIVO SOLID
DIFFUSER, 1"
FOCAL POINT, NIVO SOLID
DIFFUSER, 2"
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA A
AREA B
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/2
/2
:0
:5
P
M
AC 11.01
OVERALL REFLECTED CEILING
PLAN
TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA
2. WHERE NEW CEILINGS ARE INDICATED, REMOVE ALL EXISTING CEILINGS TO ALLOW FOR PROPER INSTALLATION OF NEW CEILINGS. PATCH & REPAIR EXISTING WALLS AS REQUIRED TO INSTALL NEW
FINISHES.
1. REPAIR EXISTING CEILING GRID AND TILES AS NECESSARY AT CONSTRUCTION TIE-INS.
RENOVATION WORK
10. PAINT INTERIOR SURFACES OF AIR DUCTS AND CONVECTOR / BASEBOARD HEATING CABINETS THAT
ARE VISIBLE THROUGH GRILLES AND LOUVERS WITH ONE COAT OF FLAT BLACK PAINT, FOR A
MINIMUM OF 1'-6" OR BEYOND SIGHT LINE, WHICHEVER IS GREATER. PAINT DAMPERS EXPOSED...
9. INSTALL CEILINGS IN ALL ROOMS AS SHOWN ON THE REFLECTED CEILING PLAN AND AS INDICATED
ON THE FINISH PLAN TO RECEIVE NEW CEILINGS.
8. ACCESS PANELS: PROVIDE ALLOWANCE FOR (2) 24" X 24" ACCESS PANELS IN EACH HARD CEILING
LOCATION IN ADDITION TO THOSE SHOWN ON THE DRAWINGS. CREDIT UNUSED ACCESS PANEL
MONIES BACK TO COR AT PROJECT CLOSEOUT. PROVIDE ACCESS PANELS WHERE REQUIRED FOR
TEST VALVES, CONTROLS, AND ABOVE CEILING MAINTENANCE THAT MEET THE RATING OF THE
ASSEMBLY IN WHICH THEY ARE INSTALLED.
7. CENTER EXIT SIGNS OVER EXIT DOORS (U.N.O.)
6. CENTER LIGHT FIXTURES, DEVICES AND SPRINKLER HEADS IN CEILING TILES.
5. CENTER CEILING GRIDS IN BOTH DIRECTIONS OF SPACE (U.N.O.)
4. CEILING MATERIALS ARE AS SHOWN. REFER TO INTERIORS PLAN FOR SPECIFICS REGARDING
TYPES OF FINISHES.
● MECHANICAL ITEMS LESS THAN 20 POUNDS MAY BE ATTACHED TO GRID.
● FOR LIGHT FIXTURES AND MECHANICAL ITEMS WITH A COMBINED WEIGHT GREATER THAN 56
POUNDS, ATTACH SEPARATE WIRES (4 MINIMUM) TO INDEPENDENTLY SUPPORT FIXTURES
FROM STRUCTURE. DO NOT INSTALL FIXTURES SUCH THAT SUPPORT FOR FIXTURES COMES
FROM CEILING GRID.
● FOR LIGHT FIXTURES, MECHANICAL ITEMS AND ATTACHMENTS WITH A COMBINED WEIGHT OF
56 POUNDS OR LESS, PROVIDE POSITIVE ATTACHMENT WITH TWO DEVICES PLUS TWO SLACK
WIRES AT DIAGONAL CORNERS.
3. SAFETY WIRES FOR LIGHTING, MPE, AND OTHER ITEMS:
2. HANG SUSPENSION SYSTEM INDEPENDENTLY OF WALLS, COLUMNS, DUCTS, PIPES AND CONDUIT.
WHERE CARRYING MEMBERS ARE SPLICED, AVOID VISIBLE DISPLACEMENT OF THE LONGITUDINAL
AXIS OR FACE PLANE OF ADJACENT MEMBERS.
1. COORDINATE ABOVE CEILING DUCTWORK, PIPES, ETC. TO MEET CEILING HEIGHTS AS SHOWN ON
DRAWINGS. REMOVE EXISTING CEILINGS INDICATED TO REMAIN TO ALLOW FOR PROPER
INSTALLATION OF ABOVE CEILING MPE WORK AND REINSTALL WHEN WORK IS COMPLETE.
ALL WORK
GENERAL CEILING NOTES
1/16" = 1'-0"
1 GROUND FLOOR OVERALL RCP
0 8' 16' 32'4'
1/16" = 1'-0"
2 MECH EQUIP PLATFORM 1 RCP
1/16" = 1'-0"
3 MECH EQUIP PLATFORM 2 RCP
0 8' 16' 32'4'0 8' 16' 32'4'
Revisions: Date:
HIGH BAY
LIGHT FIXTURE
DOWNLIGHT
DOWNLIGHT
RECESSED
EXIT LIGHT
SINGLE FACE
S
D
SPEAKER
WALL MOUNTED
LIGHT FIXTURE
EXIT LIGHT
DOUBLE FACE
SMOKE DETECTOR
LINEAR LIGHTING
CEILING MATERIAL LEGEND:
CEILING FIXTURES LEGEND:
2x2 LIGHT FIXTURE - RECESSED, SUSPENDED OR SURFACE MOUNTED
2x4 LIGHT FIXTURE - RECESSED, SUSPENDED OR SURFACE MOUNTED
1x4 LIGHT FIXTURE - RECESSED, SUSPENDED OR SURFACE MOUNTED
SUPPLY GRILLE
RETURN GRILLE
EXHAUST GRILLE
GYPSUM
BOARD
2 X 2
ACT
EXPOSED
STRUCTURE
TYP
EQ
TYP
EQ
T Y P
E Q
T Y P
E Q
ACCESS PANEL
T Y P
IC
A L
E Q
U
N O
E Q
TYPICAL
EQ
- UNO
EQ
CEILING FIXTURE MOUNTING:
FOCAL POINT, NIVO SOLID
DIFFUSER, FLUSH
FOCAL POINT, NIVO SOLID
DIFFUSER, 1"
FOCAL POINT, NIVO SOLID
DIFFUSER, 2"
J
I
G
F
E
D
C
B
A
10987
11 12
5.1 10.25.2
F3
F2
E1
I2
H3
G1
12.511.5
9.57.5
F4
F1
E2
D1
C1
B1
00 01 02 03
7.1 9.1
4.5
5.5
E.9
10.1 12.911.9
E.4
AE 05.01
AE 05.02
AE 05.01
8' - 0" 8' - 0"
8' - 0"
7' - 10"
8' - 0"
8' - 0"
8' - 0"
7' - 10"
8' - 0"
9' - 0" 8' - 0"
8' - 0"
8' - 0"
8' - 0" 15' - 0"
15' - 0"
8' - 6"
8' - 0"
STAIRS
G09
REC. THERAPY CLINIC
G08
BARBER CART
G02
FOOD SERVICE CHIEF
G03
CORRIDOR
G45
ENTRY
G01
CORRIDOR
G46
FOOD SERVICE VEND SUPPLY
G04
KITCHENETTE
G08A
MUSIC THERAPY CLINIC
G13
MUSIC STORAGE
G13A
WORK
G12A
EDUC CHIEF
G17A
RECREATION
STORAGE
G08B
HAC
G07
KINESIO GROUP THERAPY
G12
WC STORAGE
G12B
MALE
G09A
FEMALE
G09C
COURTYARD
G10
WORK AREA
G15
1,201 SF
CORRIDOR
G55
PRACTICE ROOM
G13B
PMRS CONSULT
G14
CHASE
G-104A
9' - 0"
15' - 0" 15' - 0"
615 SF
CONNECTOR
G47
AREA BAREA A
A R
E A B
A R
E A A
10' - 0"
15' - 0"
10' - 10"
B.2
C.5
C.6
E.3
E.5
F.3
12' - 0"
P6 GYP BOARD CEILING
P6
P7
P2
7' - 0"
8' - 0"
11' - 0"
AE 06.01
AC 11.03
AC 11.03
CORRIDOR TO BUILDING 7
AC 11.02
AC 11.02
12'-8"
EQ EQ
E Q
E Q
E Q
E Q
EQ EQ
AC 11.03
P1 SOFFIT
AE 08.09
AE 08.09
P6
P1
P2
P1
MALE SHOWER
G09B
FEMALE SHOWER
G09D
1'-6 5/8"
10" 8'-2" 10"
2'-6" 4'-10" 2'-6"
2'-6" 5'-5" 2'-6"
1'-5"
E Q
E Q
E Q
E Q
22.12 22.12
22.12 22.12
08.91
08.91
P1
P1
P1
11' - 0"
9' - 6"
BULKHEAD
BULKHEAD
E Q
E Q
3'-3" 6'-2" 3'-3"
8' - 0"
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA A
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/2
/2
:0
:5
P
M
AC 11.01A
GROUND FLOOR REFLECTED
CEILING PLAN AREA A
TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA
2. WHERE NEW CEILINGS ARE INDICATED, REMOVE ALL EXISTING CEILINGS TO ALLOW FOR PROPER INSTALLATION OF NEW CEILINGS. PATCH & REPAIR EXISTING WALLS AS REQUIRED TO INSTALL NEW
FINISHES.
1. REPAIR EXISTING CEILING GRID AND TILES AS NECESSARY AT CONSTRUCTION TIE-INS.
RENOVATION WORK
10. PAINT INTERIOR SURFACES OF AIR DUCTS AND CONVECTOR / BASEBOARD HEATING CABINETS THAT
ARE VISIBLE THROUGH GRILLES AND LOUVERS WITH ONE COAT OF FLAT BLACK PAINT, FOR A
MINIMUM OF 1'-6" OR BEYOND SIGHT LINE, WHICHEVER IS GREATER. PAINT DAMPERS EXPOSED...
9. INSTALL CEILINGS IN ALL ROOMS AS SHOWN ON THE REFLECTED CEILING PLAN AND AS INDICATED
ON THE FINISH PLAN TO RECEIVE NEW CEILINGS.
8. ACCESS PANELS: PROVIDE ALLOWANCE FOR (2) 24" X 24" ACCESS PANELS IN EACH HARD CEILING
LOCATION IN ADDITION TO THOSE SHOWN ON THE DRAWINGS. CREDIT UNUSED ACCESS PANEL
MONIES BACK TO COR AT PROJECT CLOSEOUT. PROVIDE ACCESS PANELS WHERE REQUIRED FOR
TEST VALVES, CONTROLS, AND ABOVE CEILING MAINTENANCE THAT MEET THE RATING OF THE
ASSEMBLY IN WHICH THEY ARE INSTALLED.
7. CENTER EXIT SIGNS OVER EXIT DOORS (U.N.O.)
6. CENTER LIGHT FIXTURES, DEVICES AND SPRINKLER HEADS IN CEILING TILES.
5. CENTER CEILING GRIDS IN BOTH DIRECTIONS OF SPACE (U.N.O.)
4. CEILING MATERIALS ARE AS SHOWN. REFER TO INTERIORS PLAN FOR SPECIFICS REGARDING
TYPES OF FINISHES.
● MECHANICAL ITEMS LESS THAN 20 POUNDS MAY BE ATTACHED TO GRID.
● FOR LIGHT FIXTURES AND MECHANICAL ITEMS WITH A COMBINED WEIGHT GREATER THAN 56
POUNDS, ATTACH SEPARATE WIRES (4 MINIMUM) TO INDEPENDENTLY SUPPORT FIXTURES
FROM STRUCTURE. DO NOT INSTALL FIXTURES SUCH THAT SUPPORT FOR FIXTURES COMES
FROM CEILING GRID.
● FOR LIGHT FIXTURES, MECHANICAL ITEMS AND ATTACHMENTS WITH A COMBINED WEIGHT OF
56 POUNDS OR LESS, PROVIDE POSITIVE ATTACHMENT WITH TWO DEVICES PLUS TWO SLACK
WIRES AT DIAGONAL CORNERS.
3. SAFETY WIRES FOR LIGHTING, MPE, AND OTHER ITEMS:
2. HANG SUSPENSION SYSTEM INDEPENDENTLY OF WALLS, COLUMNS, DUCTS, PIPES AND CONDUIT.
WHERE CARRYING MEMBERS ARE SPLICED, AVOID VISIBLE DISPLACEMENT OF THE LONGITUDINAL
AXIS OR FACE PLANE OF ADJACENT MEMBERS.
1. COORDINATE ABOVE CEILING DUCTWORK, PIPES, ETC. TO MEET CEILING HEIGHTS AS SHOWN ON
DRAWINGS. REMOVE EXISTING CEILINGS INDICATED TO REMAIN TO ALLOW FOR PROPER
INSTALLATION OF ABOVE CEILING MPE WORK AND REINSTALL WHEN WORK IS COMPLETE.
ALL WORK
GENERAL CEILING NOTES
DENOTED BY A NUMBER ENCLOSED INSIDE A HEXAGON.
ONLY NOTES APPLICABLE TO THIS SHEET ARE SHOWN.
KEYNOTE SCHEDULE
08.91 2' X 2' ACCESS PANEL
22.12 CEILING FAN. REF. MECH SCHEDULE.
1/8" = 1'-0"
1 GROUND FLOOR AREA A RCP
0 4' 8' 12'
HIGH BAY
LIGHT FIXTURE
DOWNLIGHT
DOWNLIGHT
RECESSED
EXIT LIGHT
SINGLE FACE
S
D
SPEAKER
WALL MOUNTED
LIGHT FIXTURE
EXIT LIGHT
DOUBLE FACE
SMOKE DETECTOR
LINEAR LIGHTING
CEILING MATERIAL LEGEND:
CEILING FIXTURES LEGEND:
2x2 LIGHT FIXTURE - RECESSED, SUSPENDED OR SURFACE MOUNTED
2x4 LIGHT FIXTURE - RECESSED, SUSPENDED OR SURFACE MOUNTED
1x4 LIGHT FIXTURE - RECESSED, SUSPENDED OR SURFACE MOUNTED
SUPPLY GRILLE
RETURN GRILLE
EXHAUST GRILLE
GYPSUM
BOARD
2 X 2
ACT
EXPOSED
STRUCTURE
TYP
EQ
TYP
EQ
T Y P
E Q
T Y P
E Q
ACCESS PANEL
T Y P
IC
A L
E Q
U
N O
E Q
TYPICAL
EQ
- UNO
EQ
CEILING FIXTURE MOUNTING:
FOCAL POINT, NIVO SOLID
DIFFUSER, FLUSH
FOCAL POINT, NIVO SOLID
DIFFUSER, 1"
FOCAL POINT, NIVO SOLID
DIFFUSER, 2"
J
I
H
12.5
17 18 19 22
F4
F1
E2
D1
C1
B1
H2
I1
I3
K
L
15.1 15.2
17.1 17.2
E.9
12.9
12.9
E.4
K.8
24 26
AE 05.02
J.5
15' - 0"
10' - 0"
10' - 0"
10' - 0"
ELECTRICAL
MEDIA COORD.
G17B
LOBBY
G36
MALE
G37
FEMALE
G38
VESTIBULE
G35
SECURITY
G35A
HAC
G30I
PAT. RESOURCE
G40
STORAGE
G34A
SIM MAINTENANCE
G30G
PROCEDURE SIM LAB
G30F
CONTROL ROOM
G30E
TRNG EQUIP STOR
G30C
ALS CLASSROOM
G30J
MALE
G25
WAITING
G39
LACTATION
G27
MULTI-PURPOSE
G20J
MULTI-PURPOSE
G20F
MULTI-PURPOSE
G20D
MULTI-PURPOSE
G20B
MULTI-PURPOSE
G20
MULTI-PURPOSE
G20H
STOR.
G20A
STOR.
G20E
STOR
G20G
STOR.
G20I
STOR.
G20C
MED/SURG SIM LAB
G30D
VENDING
G32
STAFF LOUNGE
G33
KITCHEN/SERVING
G21
EDUC CHIEF
G17A
WORK
G17
RT SPVR.
G15A
COMPUTER LAB
G16
CREATIVE ARTS GROUP
G34
CORRIDOR
G48
CORRIDOR
G48A
CORRIDOR
G49
CORRIDOR
G50
CORRIDOR
G51
STORAGE
G20K
FEMALE
G24
MUSIC THER. 1
G43
MUSIC THER. 2
G42 CORRIDOR
G54
CORRIDOR
G52
ACCESS STAIR
G26
PMRS STORAGE
G31
327 SF
DE-BRIEF
G30A
361 SF
CORRIDOR
G30
177 SF
STORAGE
G30H
8' - 5" 10' - 0"
10' - 0"
10' - 0" 10' - 0"
16' - 0"
8' - 9"8' - 9"
16' - 0"
16' - 0"
16' - 0"
15' - 0"
16' - 0"
8' - 9" 8' - 9" 16' - 0" 8' - 9"
8' - 6"
10' - 0"
10' - 0"
8' - 5"
8' - 5"
8' - 5"
8' - 5"
8' - 5"
9' - 0"
11' - 5"
8' - 5"
8' - 1"
7' - 10"
8' - 0"
7' - 10"
9' - 0"
9' - 0"
9' - 0"
23 25
AREA BAREA A
A R
E A B
A R
E A A
15' - 0"
10' - 0"
14' - 6"
10' - 0"
10' - 0"
10' - 0"
10' - 0"
8' - 5" 10' - 0"
10' - 0"
10' - 0"
10' - 0"
8' - 5"
10' - 0"
10' - 0" 10' - 0"
16' - 0"
16' - 0"8' - 9"8' - 9"
16' - 0"
16' - 0" 16' - 0"
9' - 0"
8' - 9"
16' - 0"
16' - 0"
15' - 0"
16' - 0"
16' - 0"
8' - 9"
8' - 9"
16' - 0"
16' - 0"
8' - 9" 8' - 9" 16' - 0" 8' - 9"
8' - 6"
10' - 0"
10' - 0"
8' - 5" 8' - 8"
8' - 5"
8' - 5"
8' - 5"
8' - 5"
8' - 5"
8' - 5"
9' - 0"
11' - 5"
8' - 5"
8' - 1"
8' - 0"
8' - 0"
7' - 10"
9' - 0"
8' - 8"
9' - 0"
8' - 8"
9' - 0"
9' - 0"
9' - 0"
8' - 4"
15' - 9"
15' - 0"
14' - 10"
9' - 0"
9' - 0"
CHARGING CART STOR.
G19
WHOLE HEALTH
STORAGE
G18
IT
G23
20 21
K.1
K.9
B.2
C.5
C.6
E.3
E.5
F.3
16.5 17.4 17.5 18.8 18.9 20.1 20.2 21.321.5
P2 P2
P2
P1
P5
P2
+ 8'-5"
ECONU2RW -STATIC
WHITE 2" LIGHT
AC 11.02
13' - 7"
AC 11.03
AC 11.03
C O
R R
ID
O
R T
O B
LD
G
EQ EQ
2' -1
5/
8" 4'
-3
/2
4' -3
/2
3'
-0
E Q
E Q
EQ EQ
E Q
E Q
EQ EQ
5'-0" 7'-11 3/4" 4'-7"
2'-3 1/2" 6'-0" 6'-0" 3'-8 1/2"
2' -1
1/
8" 6'
-0
3' -1
7/
8"
STORAGE
G30K
15' - 0"15' - 0" 15' - 0"
AE 08.09
ACOUSTIC WOOD PANELS: BASIS
OF DESIGN, ARMSTRONG
WOODWORKS LINEAR VENEERED
PLANKS
AC 11.01B
AC 11.01B
E Q
E Q
EQ EQ
2' -6
6"
1'-6"
1' -6
1/
4" 2'
-4
2' -4
1/ 4"
EQ EQ
EQ EQ EQ EQ
EQ EQ EQ EQ
+ 13'-10"
7' - 10"
8' - 0"
AC 11.02
AC 11.02
AC 11.02
AC 11.02
AC 11.02
AC 11.02
P1
P1
P1
P1
P1
3' -6
3' -6
E Q
E Q
EQ EQ
D1 8' - 9"
TYP
EQ
TYP
EQ
T Y P
E Q
T Y P
E Q
8' - 9"
TYP
EQ
TYP
EQ
T Y P
E Q
T Y P
E Q
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA B
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/2
/2
:0
:0
P
M
AC 11.01B
GROUND FLOOR REFLECTED
CEILING PLAN AREA B
TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA
2. WHERE NEW CEILINGS ARE INDICATED, REMOVE ALL EXISTING CEILINGS TO ALLOW FOR PROPER INSTALLATION OF NEW CEILINGS. PATCH & REPAIR EXISTING WALLS AS REQUIRED TO INSTALL NEW
FINISHES.
1. REPAIR EXISTING CEILING GRID AND TILES AS NECESSARY AT CONSTRUCTION TIE-INS.
RENOVATION WORK
10. PAINT INTERIOR SURFACES OF AIR DUCTS AND CONVECTOR / BASEBOARD HEATING CABINETS THAT
ARE VISIBLE THROUGH GRILLES AND LOUVERS WITH ONE COAT OF FLAT BLACK PAINT, FOR A
MINIMUM OF 1'-6" OR BEYOND SIGHT LINE, WHICHEVER IS GREATER. PAINT DAMPERS EXPOSED...
9. INSTALL CEILINGS IN ALL ROOMS AS SHOWN ON THE REFLECTED CEILING PLAN AND AS INDICATED
ON THE FINISH PLAN TO RECEIVE NEW CEILINGS.
8. ACCESS PANELS: PROVIDE ALLOWANCE FOR (2) 24" X 24" ACCESS PANELS IN EACH HARD CEILING
LOCATION IN ADDITION TO THOSE SHOWN ON THE DRAWINGS. CREDIT UNUSED ACCESS PANEL
MONIES BACK TO COR AT PROJECT CLOSEOUT. PROVIDE ACCESS PANELS WHERE REQUIRED FOR
TEST VALVES, CONTROLS, AND ABOVE CEILING MAINTENANCE THAT MEET THE RATING OF THE
ASSEMBLY IN WHICH THEY ARE INSTALLED.
7. CENTER EXIT SIGNS OVER EXIT DOORS (U.N.O.)
6. CENTER LIGHT FIXTURES, DEVICES AND SPRINKLER HEADS IN CEILING TILES.
5. CENTER CEILING GRIDS IN BOTH DIRECTIONS OF SPACE (U.N.O.)
4. CEILING MATERIALS ARE AS SHOWN. REFER TO INTERIORS PLAN FOR SPECIFICS REGARDING
TYPES OF FINISHES.
● MECHANICAL ITEMS LESS THAN 20 POUNDS MAY BE ATTACHED TO GRID.
● FOR LIGHT FIXTURES AND MECHANICAL ITEMS WITH A COMBINED WEIGHT GREATER THAN 56
POUNDS, ATTACH SEPARATE WIRES (4 MINIMUM) TO INDEPENDENTLY SUPPORT FIXTURES
FROM STRUCTURE. DO NOT INSTALL FIXTURES SUCH THAT SUPPORT FOR FIXTURES COMES
FROM CEILING GRID.
● FOR LIGHT FIXTURES, MECHANICAL ITEMS AND ATTACHMENTS WITH A COMBINED WEIGHT OF
56 POUNDS OR LESS, PROVIDE POSITIVE ATTACHMENT WITH TWO DEVICES PLUS TWO SLACK
WIRES AT DIAGONAL CORNERS.
3. SAFETY WIRES FOR LIGHTING, MPE, AND OTHER ITEMS:
2. HANG SUSPENSION SYSTEM INDEPENDENTLY OF WALLS, COLUMNS, DUCTS, PIPES AND CONDUIT.
WHERE CARRYING MEMBERS ARE SPLICED, AVOID VISIBLE DISPLACEMENT OF THE LONGITUDINAL
AXIS OR FACE PLANE OF ADJACENT MEMBERS.
1. COORDINATE ABOVE CEILING DUCTWORK, PIPES, ETC. TO MEET CEILING HEIGHTS AS SHOWN ON
DRAWINGS. REMOVE EXISTING CEILINGS INDICATED TO REMAIN TO ALLOW FOR PROPER
INSTALLATION OF ABOVE CEILING MPE WORK AND REINSTALL WHEN WORK IS COMPLETE.
ALL WORK
GENERAL CEILING NOTES
DENOTED BY A NUMBER ENCLOSED INSIDE A HEXAGON.
ONLY NOTES APPLICABLE TO THIS SHEET ARE SHOWN.
KEYNOTE SCHEDULE
1/8" = 1'-0"
1 GROUND FLOOR AREA B RCP
0 4' 8' 12'
3/8" = 1'-0"
MULTI-PURPOSE
3/8" = 1'-0"
MULTI-PURPOSE
0 1' 2' 4'6"
0 1' 2' 4'6"
5/8" GYP. BD. (TYP.)
6" METAL STUDS ANCHORED TO
AND BRACED FROM STRUCTURE
ABOVE
ACOUSTICAL CEILING TILE
7 1/4"
2" 4"
V A R
IE
S
4"
ACOUSTICAL
CEILING TILE
5/8" GYP. BD. (TYP.)
3-5/8" METAL STUDS
ANCHORED TO AND
BRACED FROM
STRUCTURE ABOVE
ACOUSTICAL
CEILING TILE
VARIES
ACOUSTICAL
CEILING TILE
V A R
IE
S
4"
V A R
IE
S
4"
3-5/8" METAL STUDS
REFER TO CEILING PLAN FOR ELEV A.F.F.
3-5/8" METAL KICKER
STUD ANCHORED TO
STRUCTURE ABOVE
LIGHT FIXTURE WITH
TRIM (WHERE SHOWN)
GYPBOARD CEILING
HAT CHANNEL
STRUT COVER PAINTED TO
MATCH CEILING
STRUTS PER
STRUCTURAL & VENDOR
REQUIREMENTS.
SEALANT
C-CHANNEL SUPPORTED BY
STRUCTURE ABOVE. RUN
INTERMEDIATE SUPPORT
CHANNELS PERPENDICULAR &
ACROSS TOP OF UNISTRUT FOR
ADDITIONAL SUPPORT.
5/8" GYP. BD.
(TYP.)
3-5/8" METAL STUDS
ANCHORED TO AND
BRACED FROM
STRUCTURE ABOVE
ACOUSTICAL
CEILING TILE
3-5/8" METAL STUDS
REFER TO CEILING PLAN
FOR ELEV A.F.F.
3-5/8" METAL KICKER
STUD ANCHORED TO
STRUCTURE ABOVE
LIGHT FIXTURE WITH
TRIM (WHERE SHOWN)
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/2
/2
:0
:0
P
M
AC 11.02
CEILING DETAILS TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA
1 BULKHEAD DETAIL 2 SOFFIT DETAIL 3 GYP CEILING @ STRUT
0 2" 6"4" 0 2" 6"4" 0 2" 6"4"
0 2" 6"4"
4 SOFFIT DETAIL @ ALCOVE
3' -1 /8
METAL STUD
FRAMING (3-5/8"), 20
GA MIN AT 16" O.C.
MAX
GYPSUM BOARD,
TYPE 'X' FIRE-RATED
(5/8")
METAL STUD FRAMING (3-5/8"),
20 GA MIN AT 16" O.C. MAX
GYPSUM BOARD, TYPE 'X'
FIRE-RATED (5/8")
TYP
6"
ACOUSTICAL LIGHT
FIXTURE, REF
ELECTRICAL
DRAWINGS FOR
MORE INFORMATION
M A X
1' -6
TYP
6"
TYP
EQ
TYP
EQ
7/ 8"
TYP
6"
ACOUSTICAL BAFFEL BEYOND
ACOUSTIC BAFFLE: BASIS OF
DESIGN, ARMSTRONG FELTWORKS
BLADES
1'-6 5/8"
SCHEDULED
CEILINGS
GYPSUM BOARD,
TYPE 'X' FIRE-RATED
(5/8")
METAL STUD FRAMING
(3-5/8"), 20 GA MIN, AT
16" O.C. MAX.
5' -6
4" BATT INSULATION
9' -6 A .F .F
11 3/8"3'-1 1/4"
SCHEDULED CEILING
GYPSUM BOARD, TYPE 'X'
FIRE-RATED (5/8")
METAL STUD FRAMING (3-5/8"),
20 GA MIN AT 16" O.C. MAX
1' -1 1"
3"
SCHEDULED CEILING
GYPSUM BOARD,
TYPE 'X' FIRE-RATED
(5/8")
'-7 A .F .F
3-5/8" METAL KICKER
METAL STUD FRAMING
(3-5/8"), 20 GA MIN AT 16"
O.C. MAX
GYPSUM BOARD,
TYPE 'X' FIRE-RATED
(5/8")
SCHEDULED
CEILING
SCHEDULED CEILING
2"
1' -1 1"
'-1 0" A .F .F
HANGER WIRE TO
STRUCTURE
ACOUSTIC WOOD PANELS: BASIS
OF DESIGN, ARMSTRONG
WOODWORKS LINEAR VENEERED
PLANKS
3' -2
2"
SCHEDULED CEILING
GYPSUM BOARD, TYPE 'X'
FIRE-RATED (5/8")
METAL STUD FRAMING
(3-5/8"), 20 GA MIN AT
16" O.C. MAX
SCHEDULED CEILING
COLUMN BEYOND
REC. THERAPY CLINIC
G08
5 1/2"
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/2
/2
:0
:1
P
M
AC 11.03
CEILING DETAILS TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA
4 CORRIDOR G-055 CEILING 02 5 CORRIDOR G-055 CELING
1 LOBBY CEILING 2 LOBBY CEILING 02
0 2" 1'4" 6"
0 2" 1'4" 6" 0 2" 1'4" 6"
3 REC THERAPY CEILING
0 2" 1'4" 6"
0 2" 1'4" 6"
UP
UP
UP
72.0'
72.0'
.0
AX_ ANLD R 3/ 32
R O MANS
ELECTRICAL
G41
SIM MAINTENANCE
G30G
PROCEDURE SIM LAB
G30FCONTROL ROOM
G30E
WAITING
G39
MULTI-PURPOSE
G20J
MULTI-PURPOSE
G20F
MULTI-PURPOSE
G20D
MULTI-PURPOSE
G20B
MULTI-PURPOSE
G20
MULTI-PURPOSE
G20H
STOR.
G20C
MED/SURG SIM LAB
G30D KITCHEN/SERVING
G21
EDUC CHIEF
G17A
MUSIC THERAPY CLINIC
G13
WC STORAGE
G12B
REC. THERAPY CLINIC
G08
COMPUTER LAB
G16
STOR.
G20A
STOR.
G20E
STOR
G20G
STOR.
G20I
BARBER CART
G02FOOD SERVICE CHIEF
G03
FOOD SERVICE VEND SUPPLY
G04
AREA B
AREA A
CORRIDOR
G54
CORRIDOR
G52
MUSIC THER. 1
G43
MUSIC THER. 2
G42
CORRIDOR
G45
WORK AREA
G15
ENTRY
G01
CORRIDOR
G46
COURTYARD
G10
CORRIDOR
G48
CORRIDOR
G48A
CORRIDOR
G49
CORRIDOR
G50
CORRIDOR
G51
STORAGE
G20K
PRACTICE ROOM
G13B
MUSIC STORAGE
G13A
ALS CLASSROOM
G30J
TRNG EQUIP STOR
G30C
STAFF LOUNGE
G33
CREATIVE ARTS GROUP
G34
LOBBY
G36
PMRS STORAGE
G31
ACCESS STAIR
G26
FEMALE
G24
MALE
G25
LACTATION
G27
HAC
G30I
MALE
G37
FEMALE
G38
MEDIA COORD.
G17B
WORK
G17
PAT. RESOURCE
G40
RT SPVR.
G15A
PMRS CONSULT
G14
HAC
G07
RECREATION
STORAGE
G08B
MALE
G09A
FEMALE
G09C
COPIER
COPIER
VENDING
G32
KINESIO GROUP THERAPY
G12
COPIER
RECEPT.
SAFE
WORK
G12A
C O R R
ID
O R T O B
LD
G
CORRIDOR TO BLDG 7
KITCHENETTE
G08A
A R E A B
A R E A A
VESTIBULE
G35
SECURITY
G35A
STORAGE
G34A
CORRIDOR
G55
BASEMENT ACCESS
STORAGE
G30K
STORAGE
G30H
DE-BRIEF
G30A
CORRIDOR
G30 CORRIDOR
G30
CONNECTOR
G47
FEMALE SHOWER
G09D
MALE SHOWER
G09B
ENTRY
G44
CORRIDOR
G53
CHARGING CART STOR.
G19WHOLE HEALTH
STORAGE
G18
OUTLINE SHOWS
MECHANICAL ROOM
ABOVE, REF. 3/AE
01.01
OUTLINE SHOWS FIRST FLOOR
ABOVE, REF. 2/AE 01.01
IT
G23
CHASE
G26A
CLO.
G30B
COMM/MEDIA CONTROL
G22
RISER
G13D
MECH.
G11
ELEC.
G28
ELEC.
G29
MECH.
G11A
STAIRS
G09
CORRIDOR
G46
ROOF
ROOF
ROOF
AE 01.01C
REC THERAPY BELOW
AHU - 3
STAIR
G10
MECH EQUIP PLATFORM 1
100A
MECH EQUIP PLATFORM 1
100B
AHU - 1
AHU - 2
MULTIPURPOSE ROOM BELOW
AE 01.01C
WALKING PATH
SIM LAB AREA BELOWROOF BELOW
MECH EQUIP PLATFORM 2
CORRIDOR TO BLDG 7
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA A
AREA B
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/2
/2
:0
:2
P
M
AE 01.01
GROUND FLOOR OVERALL PLAN TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
MC
1/16" = 1'-0"
1 GROUND FLOOR OVERALL PLAN
13. FRAME & DOOR FIRE LABELS: CLEAN PAINT OFF ALL NEW AND EXISTING FIRE LABELS IN SCOPE
OF WORK.
12. STRUCTURAL SUPPORTS: PROVIDE STRUCTURAL SUPPORTS ABOVE CEILING WHERE REQUIRED
FOR CEILING HUNG EQUIPMENT.
11. HAND, CRASH & BUMPER RAILS: TERMINATE HAND, CRASH & BUMPER RAILS 2” FROM EDGE OF DOOR FRAMES, FEC'S, WALL OPENINGS, CG'S, ETC., (U.N.O.) MINIMUM LENGTH OF HAND, CRASH
& BUMPER RAIL SHALL BE 24”.
10. CURTAIN TRACKS: SEE REFLECTED CEILING PLAN FOR LOCATIONS OF CUBICLE CURTAIN
TRACKS. PROVIDE CONT. BLOCKING ABOVE CEILING FOR CURTAIN TRACK ANCHORAGE.
9. SURFACE PREP: PREP SURFACES FOR NEW FINISHES ACCORDING TO SPECIFICATIONS AND
MANUFACTURERS RECOMMENDATIONS. PREPARE EXISTING WALLS TO REMAIN TO RECEIVE
NEW FINISH IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SEE EXTENT OF
EXISTING WALL TO REMAIN ON PLAN.
8. FURR OUT AROUND COLUMNS, PIPES, UTILITES, ETC., WITH THE MINIMUM DEPTH NECESSARY
TO CONCEAL PIPES.
7. WHERE DOOR IS SHOWN IN CORNER OF ROOM, LOCATE OUTSIDE EDGE OF DOOR FRAME 4"
FROM ADJACENT PERPENDICULAR WALL, (U.N.O.). ALLOW FOR PROTRUDING HARDWARE.
6. CUT AND PATCH EXISTING GYPSUM BOARD PARTITIONS TO CONCEAL ROUTING OF UTILITY
SERVICES, PIPES, ETC., UNLESS OTHERWISE PROHIBITED BY CODES.
5. BLOCKING: PROVIDE IN ALL WALLS WHERE REQUIRED FOR HANDRAILS, WALL GUARDS, FOR
SHELVING, WALL CABINETS, WALL MOUNTED DOOR STOPS AND EQUIPMENT. CUT AND PATCH
GYPSUM BOARD IN EXISTING WALLS FOR INSTALLATION OF NEW BLOCKING WHERE REQUIRED.
PROVIDE BLOCKING IN ALL WALLS AT WATER CLOSET LOCATIONS FOR GRAB BAR INSTALLATION
WHETHER GRAB BARS ARE INDICATED OR NOT. WOOD BLOCKING IS NOT ALLOWED.
4. RATED WALLS: INSURE WALLS INDICATED AS RATED FIRE AND / OR SMOKE BARRIERS ARE
CONTINUOUS CONSTRUCTION (THRU CORNERS AND TO THE DECK ABOVE) AND PENETRATIONS
ARE PROPERLY FIRE SEALED.
3. INSTALL ACOUSTICAL BATT INSULATION IN ALL INTERIOR PARTITIONS, (U.N.O.)
2. ALL PARTITIONS ARE TO BE CONTINUOUS TO THE STRUCTURE ABOVE, (U.N.O.)
1. VERIFY ALL DIMENSIONS/WORK TO BE DONE BASED ON EXISTING CONDITIONS. NOTIFY COR
IMMEDIATELY OF ANY CONFLICTS.
GENERAL ARCH. NOTES
0 8' 16' 32'4'
1/16" = 1'-0"
2 MECH EQUIP PLATFORM 1 FLOOR PLAN
1/16" = 1'-0"
3 MECH EQUIP PLATFORM 2 FLOOR PLAN
0 8' 16' 32'4'0 8' 16' 32'4'
UP
M E
D B
A L L
R A
C K
A D
D U
C T
IO
N
/A B
D U
C T
S T
A C
K G
Y M
B A
T C
A F
U S
IO
N
D B
E L
L R
A C
K
R O
W
IN
G M
A C
H
IN
E
S T
A C
K C
A B
L E
S T
A C
K
INCLINE
BENCH
B A
T C
A F
U S
IO
N
D B
E L
L R
A C
K
S T
A C
K G
Y M
S T
A C
K C
A B
L E
B A
C K
E X
T E
N S
IO
N
DBELL
STORAGE
B A
R B
E L L
H O
L D
E R
B A
R B
E L L
H O
L D
E R
W STORAGE
W STORAGE
B O
X
W O
R K
B E
N C
H W
O R
K B
E N
C H
W O
R K
B E
N C
H
INCLINE
BENCH
C
AB
C A
B . C
A B
C A
B
C A
B
C A
B
C A
B
C A
B
C A
B
C A
B
C A
B
R O
W
IN
G M
A C
H
IN
E
R O
W
IN
G M
A C
H
IN
E
R O
W
IN
G M
A C
H
IN
E
S A
F E
FREEZER
UP
UP
W A
L L R
A C
K W
H E
E L
UP
.8
J
I
G
F
E
D
C
B
A
5.1 10.25.2
F3
F2
E1
I2
H3
G1
12.511.5
9.57.5
F4
C1
B1
00 01 02 03
STAIRS
7.1 9.1
REC. THERAPY CLINIC
G08
BARBER CART
G02
FOOD SERVICE CHIEF
G03
AREA BAREA A
CORRIDOR
G45
ENTRY
G01
CORRIDOR
G46
FOOD SERVICE VEND SUPPLY
G04
4.5
5.5
E.9
10.1 12.911.9
E.4
AE 05.01
AE 05.01
615 SF
CONNECTOR
G47
A R
E A
B
A R
E A
A
KITCHENETTE
G08A
MUSIC THERAPY CLINIC
G13
MUSIC STORAGE
G13A
WORK
G12A
EDUC CHIEF
G17A
RECREATION
STORAGE
G08B
HAC
G07
KINESIO GROUP THERAPY
G12
WC STORAGE
G12B
MALE
G09A
FEMALE
G09C
COURTYARD
G10
WORK AREA
G15
1,201 SF
CORRIDOR
G55
PRACTICE ROOM
G13B
PMRS CONSULT
G14
AE 02.04
AE 02.06
AE 02.02
3/ AE 04.02
4/ AE 04.02
MAT TABLE
S T
E P
P E
R
S T
E P
P E
R
S T
E P
P E
R
S T
E P
P E
R
T R
E A
D M
IL
L
T R
E A
D M
IL
L
T R
E A
D M
IL
L
T R
E A
D M
IL
L
WC SCALE
PARALLEL BARS
B
IK
E
B
IK
E
B
IK
E
B
IK
E
B B B B
B B B B B B B B
CCCCCCCC
COPIER
COPIER
26.01
08.01
CHASE
G-104A
03.01
09.01
BASEMENT
ACCESS
A
E
.0
4/ AE 09.05
A
E
.0
A
E
.0
4/ AE 02.04
1/ AE 09.01
A
E
.0
3/ AE 09.01
5/ AE 09.01
6/ AE 09.01
11/ AE 09.04
2/ AE 09.02
AE 06.02
G04 G03
G02
G14 G15 G15C
G07
G08A
G08
G08B
G09B
G12A
G09C
G12E
G12
G12B
G13A G13B
G13
G13C
G47D
G09
G47C
G47A
G47B
MALE SHOWER
G09B
FEMALE SHOWER
G09D
G09D
4/ AE 09.06
10/ AE 09.01
A
E
.0
1/ AE 09.02
G09A
COPIER
7/ AE 09.01
R A
M P
D N
REFRIG. I. MAKER
5/ AE 02.04
E.3
E.5
F.3
5/ AE 03.04
REFRIG.
AE 06.01
AE 06.01
12/ AE 09.04
A
E
.0
3/ AE 03.04
4/ AE 03.04
2/ AE 03.04
1/ AE 03.04
G11B G11A
05.40
G11
5/ AE 01.01C
A
E
.0
C
AE 01.01C
A
E
.0
A
E
.0
A
E
.0
A
E
.0
F
10.90
03.04
03.04
10.91G46
06.83
04.66
AE 08.03
AE 08.04
04.66
05.01
04.67
AE 08.02
22.13
22.13
AE 08.02
12.6212.62
12.73
12.73
12.6212.62
SLOPE
1/8" =1'-0"
SLOPE
1/8" =1'-0"
S
LO
P E
1/ 8"
1'
-0
S
LO
P E
1/ 8"
1'
-0
22.03
22.02
22.04
10.66
10.03
11.60
08.02
G01
5/ AE 04.01
07.0107.01
P
AE 06.01
AAAA
G54B
G54A
CORRIDOR TO BUILDING 7
AE 08.03
H G
H G
AE 08.03
Sim
AE 08.03
Sim AE 08.04
5A
5A
1A
1A
2A
1A
5A
1A
2A
2 1 2
2 2
1A
2A 2A
1A 1A
1A
2A
1A
1A
2A
1A 1A
1A
1A
1A
1A 1A
2A
21A
1B1B
1A
1A
1A
E
10.71
10.71
10.71
10.71
SOILED
G12D
CLEAN
G12CG12C
G12D
MECH.
G11
MECH.
G11A
G45
STAIRS
G09
ELEC.
G28
ELEC.
G29
G13D
RISER
G13D
AE 08.07
10.22
10.22
AE 08.04
AE 08.04
07.70
07.70
A
E
.0
10/ AE 08.02
AE 01.01C
Sim
04.66 04.66
NO RATING - 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON BOTH SIDES
1 HR FIRE RATED - 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON BOTH SIDES
WALL LEGEND
1B
NO RATING - 2 1/2" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON ONE SIDE
NO RATING - 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON ONE SIDE
NO RATING - 7/8" HAT CHANNELS W/ 1 LAYER GYPSUM BOARD ON ONE SIDE
NO RATING - 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON ONE SIDE AND 2" INSULATION5
NO RATING - 6" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON EACH SIDE6
NO RATING - 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON OUTSIDE OF THE ROOM AND
2 LAYERS OF GYPSUM BOARD ON INSIDE OF ROOM
8 NO RATING - 3 5/8" MTL. STUD W/ 2 LAYERS GYPSUM BOARD ON ONE SIDE
9 NO RATING - 3 5/8" MTL. STUD W/1 LAYER OF 5/8" GYP. BD AND 1 LAYER OF 5/16" BULLET
RESISTANT PANEL ON ONE SIDE AND 1 LAYER OF 5/8" GYP. PANEL ON THE OTHER
NON RATED SMOKE BARRIER- 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON
BOTH SIDES
1A
NON RATED SMOKE BARRIER - 6" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON EACH SIDE6A
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA A
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/2
/2
:0
:3
P
M
AE 01.01A
GROUND FLOOR PLAN AREA A TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA/MC
0 4' 8' 12'
1/8" = 1'-0"
1 GROUND FLOOR PLAN AREA A
13. FRAME & DOOR FIRE LABELS: CLEAN PAINT OFF ALL NEW AND EXISTING FIRE LABELS IN SCOPE
OF WORK.
12. STRUCTURAL SUPPORTS: PROVIDE STRUCTURAL SUPPORTS ABOVE CEILING WHERE REQUIRED
FOR CEILING HUNG EQUIPMENT.
11. HAND, CRASH & BUMPER RAILS: TERMINATE HAND, CRASH & BUMPER RAILS 2” FROM EDGE OF DOOR FRAMES, FEC'S, WALL OPENINGS, CG'S, ETC., (U.N.O.) MINIMUM LENGTH OF HAND, CRASH
& BUMPER RAIL SHALL BE 24”.
10. CURTAIN TRACKS: SEE REFLECTED CEILING PLAN FOR LOCATIONS OF CUBICLE CURTAIN
TRACKS. PROVIDE CONT. BLOCKING ABOVE CEILING FOR CURTAIN TRACK ANCHORAGE.
9. SURFACE PREP: PREP SURFACES FOR NEW FINISHES ACCORDING TO SPECIFICATIONS AND
MANUFACTURERS RECOMMENDATIONS. PREPARE EXISTING WALLS TO REMAIN TO RECEIVE
NEW FINISH IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SEE EXTENT OF
EXISTING WALL TO REMAIN ON PLAN.
8. FURR OUT AROUND COLUMNS, PIPES, UTILITES, ETC., WITH THE MINIMUM DEPTH NECESSARY
TO CONCEAL PIPES.
7. WHERE DOOR IS SHOWN IN CORNER OF ROOM, LOCATE OUTSIDE EDGE OF DOOR FRAME 4"
FROM ADJACENT PERPENDICULAR WALL, (U.N.O.). ALLOW FOR PROTRUDING HARDWARE.
6. CUT AND PATCH EXISTING GYPSUM BOARD PARTITIONS TO CONCEAL ROUTING OF UTILITY
SERVICES, PIPES, ETC., UNLESS OTHERWISE PROHIBITED BY CODES.
5. BLOCKING: PROVIDE IN ALL WALLS WHERE REQUIRED FOR HANDRAILS, WALL GUARDS, FOR
SHELVING, WALL CABINETS, WALL MOUNTED DOOR STOPS AND EQUIPMENT. CUT AND PATCH
GYPSUM BOARD IN EXISTING WALLS FOR INSTALLATION OF NEW BLOCKING WHERE REQUIRED.
PROVIDE BLOCKING IN ALL WALLS AT WATER CLOSET LOCATIONS FOR GRAB BAR INSTALLATION
WHETHER GRAB BARS ARE INDICATED OR NOT. WOOD BLOCKING IS NOT ALLOWED.
4. RATED WALLS: INSURE WALLS INDICATED AS RATED FIRE AND / OR SMOKE BARRIERS ARE
CONTINUOUS CONSTRUCTION (THRU CORNERS AND TO THE DECK ABOVE) AND PENETRATIONS
ARE PROPERLY FIRE SEALED.
3. INSTALL ACOUSTICAL BATT INSULATION IN ALL INTERIOR PARTITIONS, (U.N.O.)
2. ALL PARTITIONS ARE TO BE CONTINUOUS TO THE STRUCTURE ABOVE, (U.N.O.)
1. VERIFY ALL DIMENSIONS/WORK TO BE DONE BASED ON EXISTING CONDITIONS. NOTIFY COR
IMMEDIATELY OF ANY CONFLICTS.
GENERAL ARCH. NOTES
DENOTED BY A NUMBER ENCLOSED INSIDE A HEXAGON.
ONLY NOTES APPLICABLE TO THIS SHEET ARE SHOWN.
KEYNOTE SCHEDULE
03.01 INFILL NEW COURTYARD WITH PAVERS IN A HERRINGBONE PATTERN ON A BED OF
DRAINAGE GRAVEL. SLOPE THE COURTYARD TO DRAIN. REF. CIVIL AND PLUMBING FOR
MORE INFORMATION
03.04 CONCRETE STAIRS WITH RAILING
04.66 USE SALVAGED BRICK FROM DEMOLITION FOR BRICK INFILL. MATCH THE COLOR OF THE
EXISTING MORTAR EVEN IF EXISTING MORTAR IS SLIGHTLY DISCOLORED. INFILL SHALL
MATCH THE EXISTING WALL CONSTURCITON.
04.67 USE SALVAGED BRICK FROM DEMOLITION FOR BRICK INFILL. MATCH THE COLOR OF THE
EXISTING MORTAR EVEN IF EXISTING MORTAR IS SLIGHTLY DISCORLORED. INFILL BRICK AS
NECESSARY AROUND NEW DOOR. ALIGN THE EDGES OF THE INFILL WITH THE EXISTING
WALL ON THE INTERIOR AND EXTEIOR. INFILL SHALL MATCH THE EXISTING WALL
CONSTRUCTION
05.01 REPLACE EXISTING EXPANSION JOINT. FACILITY STANDARD IS BELZONA SYSTEMS.
05.40 METAL PANEL WALL SCREEN AROUND TRANSFORMER PAD. PANEL TO BE HELD OFF FINISH
GRADE 12". BASIS OF DESIGN: INDUSTRIAL LOUVERS, INC. MODEL 450XPI, COLOR TO BE
MEDIUM BRONZE. SUBMIT COLOR SAMPLE TO COR FOR FINAL APPROVAL.
06.83 SOLID SURFACE SHOWER PAN. CHIP OUT EXISITNG SLAB AND DEPRESS NEW SLAB TO
ACCOMMODATE SHOWER PAN. REF. DETAIL
07.01 CLEAN EXISTING LIMESTONE AROUND CURTIAN WALL. PATCH/REPAIR ALL CRACKS AND
DAMAGE TO THE LIMESTONE IN PLACE. RESEAL ALL JOINTS ALONG THE LIMESTONE.
07.70 DASHED LINE REPRESENTS EXTENT OF WATERPROOFING THAT SHOULD BE ADDED TO THE
EXISTING WALL WHERE THE GRADE HAS BEEN RAISED. REF. DETAIL 10/AE 08.04 FOR DETAIL
AND CIVIL FOR GRADING PLAN FOR HEIGHT OF GRADE
08.01 CREATE NEW DOORWAY INTO STAIRWELL. PATCH ANY EXISTING CMU DAMAGED FROM
DEMOLITION
08.02 FILL IN EXISTING DOOR OPENING TO MATCH CMU. SEAL WITH FIRESTOPPING
09.01 NEW FINISHES THE LENGTH OF THE CORRIDOR, INCLUDING FLOORING, PAINT, AND
CEILINGS.
10.03 SAFE - VA PROVIDED AND INSTALLED
10.22 FOLDING WALL MOUNTED SHOWER SEAT. BASIS OF DESIGN: DREAMLINE 2)" FOLDING WOOD
WALL MOUNTED SHOWER SEAT MODEL # SHST-02-TN. SEAT SHALL BE INSTALLED 18" A.F.F.
PROVIDE IN WALL BLOCKING AT ATTACHEMENT POINT PER MANF. SHOP DRAWINGS.
10.66 JANITOR'S UTILITY SHELF, STAINLESS STEEL
10.71 FIRE EXTINGUISHER CABINET (FEC), SEMI-RECESSED
10.90 CANOPY, ALUMINUNM, WITH INTERGAL DRAINAGE TO A SCUPPER AND DOWNSPOUT.
BRONZE ANODIZED FINISH, SUBMIT COLOR SAMPLE FOR FINAL VA SELECTION. PROVIDE
SUPPORT ON INTERIOR SIDE OF BUILDING TIED TO STRUCTURE FOR ANCHORAGE.BASIS OF
DESIGN: MAPES SUPER LUMIDECK. REMOVE BICK TO ANCHOR AWNING TO EXISTING CMU
WALL. REPLACE BRICK AS REQUIRED.
10.91 CANOPY, ALUMINUNM, WITH INTERGAL DRAINAGE TO A SCUPPER AND DOWNSPOUT.
BRONZE ANODIZED FINISH, SUBMIT COLOR SAMPLE FOR FINAL VA SELECTION. PROVIDE
SUPPORT ON INTERIOR SIDE OF BUILDING TIED TO STRUCTURE FOR ANCHORAGE.BASIS OF
DESIGN: MAPES SUPER LUMIDECK.
11.60 POOL TABLE, VA PROVIDED AND INSTALLED
12.62 F0265 - RECLINER - VA PROVIDED AND INSTALLED
12.73 F0600 - CREDENZA - VA PROVIDED AND INSTALLED
22.02 PRIMARY COURTYARD DRAIN. REF. PLUMBING
22.03 OVERFLOW COURTYARD DRAIN. REF. PLUMBING
22.04 MOP SINK - CONTRACTOR PROVIDED AND INSTALLED
22.13 FLOOR DRAIN. SLOPE FLOOR TO DRAIN MIN 1/8" PER FOOT.
26.01 PROVIDE ELECTRICAL AND DATA ROUGH IN'S FOR FUTURE T.V. REF. DETAILS FOR
MOUNTING HEIGHTS
S O
M A
T R
O N
R E
C L
IN
E R
M O
B
IL
E S
T O
R A
G
E IN
T E
R S
O U
L R
E C
L
IN
E R
M O
B
IL
E S
T O
R A
G E
CR
72.0'
72.0'
.0
A X_ AN LD R 3/ 32
R O M AN S
J
I
H
F
G1
12.5
17 18 19 22
F4
F1
E2
D1
C1
B1
H2
I1
I3
K
L
15.1 15.2 17.1 17.2
K.8
24 26
A
E
.0
A
E
.0
AE 05.02
AE 05.02
AE 05.02
MEDIA COORD.
G17B
LOBBY
G36
MALE
G37
FEMALE
G38
VESTIBULE
G35
SECURITY
G35A
58 SF
HAC
G30I
PAT. RESOURCE
G40
STORAGE
G34A
SIM MAINTENANCE
G30G
PROCEDURE SIM LAB
G30F
CONTROL ROOM
G30E
TRNG EQUIP STOR
G30C
499 SF
ALS CLASSROOM
G30J
MALE
G25
WAITING
G39
LACTATION
G27
MULTI-PURPOSE
G20J
MULTI-PURPOSE
G20F
MULTI-PURPOSE
G20D
MULTI-PURPOSE
G20B
MULTI-PURPOSE
G20
MULTI-PURPOSE
G20H
STOR.
G20A
STOR.
G20E STOR
G20G
STOR.
G20I
STOR.
G20C
MED/SURG SIM LAB
G30D
VENDING
G32
STAFF LOUNGE
G33
KITCHEN/SERVING
G21
EDUC CHIEF
G17A
WORK
G17
RT SPVR.
G15A
COMPUTER LAB
G16
CREATIVE ARTS GROUP
G34
CORRIDOR
G48
CORRIDOR
G48A
CORRIDOR
G49
CORRIDOR
G50
CORRIDOR
G51
STORAGE
G20K
FEMALE
G24
MUSIC THER. 1
G43 MUSIC THER. 2
G42
CORRIDOR
G54
CORRIDOR
G52
ACCESS STAIR
G26
PMRS STORAGE
G31
AE 02.03
AE 02.05
AE 02.02
7/ AE 04.02
5/ AE 04.02
BBBB
C O P
IE
R
J.5
AE 05.02
10.09
10.09
10.09
10.09
10.09
26.02
10.90
327 SF
DE-BRIEF
G30A
361 SF
CORRIDOR
G30
177 SF
STORAGE
G30H
10.01
01.01
65 SF
STORAGE
G30K
23 25
AREA BAREA A
A R E A B
A R E A A
10.02
C O R R
ID
O R T O B
LD
G
8/ AE 02.02
6/ AE 09.04
3/ AE 09.04
4/ AE 09.04
6/ AE 09.06
10/ AE 09.04
A
E
.0
9/ AE 09.03
A
E
.0
5/ AE 09.03
2/ AE 09.06
3/ AE 09.06
A
E
.0
1/ AE 09.03
2/ AE 09.03
A
E
.0
A
E
.0
E E
AE 06.02
B
G35G35B
G35A
G37
G38
G34
G34A
G33
G32
G31 G30-3
G21
G50
G20K
G51G20J
G20H2
G20IG20H1G20FG20GG20EG20DG20-1G20A
G20-2
G20B
G20C
G17D
G17B
G17
G17A
G47B
G16B
G16A
G15C
G15A
G43 G42 G41 G40
G30-2G27
G26
G25
G24
G30HG30I
G30J
G30A
G30C
G30K
G30-1
G39
217 SF
CORRIDOR
G30
G48
A
E
.0
A
E
.0
7/ AE 02.02
5/ AE 02.02
WHOLE HEALTH
STORAGE
G18 m a n e q u in s to ra g e r a c k
CHARGING CART STOR.
G19
AE 06.02
AE 02.05
A
E
.0
3/ AE 09.02
4/ AE 09.02
CORRIDOR
G53
G19
G18
G17C
IT
G23
G22G23
10.8110.81
20 21
K.1
K.9
B.2
C.5
C.6
E.3
E.5 E.5
F.3
16.5 17.4 17.5 18.8 18.9 20.1 20.2 21.3 21.5
11.42
10/ AE 09.03
A
E
.0
A
E
.0
12.91
12.91
8/ AE 09.01
A
E
.0
8/ AE 09.04
A
E
.0
2/ AE 04.01
AE 06.02
AE 06.01
A
E
.0
10.90
22.01
22.04
A
E
.0
9/ AE 03.04
A
E
.0
13/ AE 03.04
CONNECTOR
G47
5/ AE 01.01C
AE 06.02
A
E
.0
G30D G30E G30F G30G G52
04.66
04.66 04.66
AE 08.03
AE 08.03
AE 08.03
4' -0
G30A-2
CHASE
G26A
CLO.
G30B
9' -0
4' -0
09.82
09.82
22.07
22.0511.99 11.98
05.01
22.11
A
E
.0
7/ AE 09.03
AE 08.07
06.6006.60
22.04
2 1
1A
1A
1A
1A
1A1A
2A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1 3
1A
1A2
1A
1A
1A
1A
1A
11B
1B
1B
1B
1B
1B
1A
1A 1A
2 2
1A
1A 1A
1A 1A
1A
1A
21B
1B1B
1 12
1A
10.08
10.08 10.08
10.08
10.08 7 1/ 2"
5/ 8"
AE 08.03
Sim
AE 08.03
Sim
AE 08.03
Sim
10.71
10.71
10.71
11.24
27.02 27.0209.30 09.30
11.24
J
K
L
M
N
COMM/MEDIA CONTROL
G22
1A
1A
2A
AE 10.02
ELECTRICAL
G41
G49
CORRIDOR
G45
AE 08.07
SIM
NO RATING - 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON BOTH SIDES
1 HR FIRE RATED - 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON BOTH SIDES
WALL LEGEND
1B
NO RATING - 2 1/2" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON ONE SIDE
NO RATING - 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON ONE SIDE
NO RATING - 7/8" HAT CHANNELS W/ 1 LAYER GYPSUM BOARD ON ONE SIDE
NO RATING - 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON ONE SIDE AND 2" INSULATION5
NO RATING - 6" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON EACH SIDE6
NO RATING - 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON OUTSIDE OF THE ROOM AND
2 LAYERS OF GYPSUM BOARD ON INSIDE OF ROOM
8 NO RATING - 3 5/8" MTL. STUD W/ 2 LAYERS GYPSUM BOARD ON ONE SIDE
9 NO RATING - 3 5/8" MTL. STUD W/1 LAYER OF 5/8" GYP. BD AND 1 LAYER OF 5/16" BULLET
RESISTANT PANEL ON ONE SIDE AND 1 LAYER OF 5/8" GYP. PANEL ON THE OTHER
NON RATED SMOKE BARRIER- 3 5/8" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON
BOTH SIDES
1A
NON RATED SMOKE BARRIER - 6" MTL. STUD W/ 1 LAYER GYPSUM BOARD ON EACH SIDE6A
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA B
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/2
/2
:0
:4
P
M
AE 01.01B
GROUND FLOOR PLAN AREA B TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA/MC
1/8" = 1'-0"
1 GROUND FLOOR PLAN AREA B
13. FRAME & DOOR FIRE LABELS: CLEAN PAINT OFF ALL NEW AND EXISTING FIRE LABELS IN SCOPE
OF WORK.
12. STRUCTURAL SUPPORTS: PROVIDE STRUCTURAL SUPPORTS ABOVE CEILING WHERE REQUIRED
FOR CEILING HUNG EQUIPMENT.
11. HAND, CRASH & BUMPER RAILS: TERMINATE HAND, CRASH & BUMPER RAILS 2” FROM EDGE OF DOOR FRAMES, FEC'S, WALL OPENINGS, CG'S, ETC., (U.N.O.) MINIMUM LENGTH OF HAND, CRASH
& BUMPER RAIL SHALL BE 24”.
10. CURTAIN TRACKS: SEE REFLECTED CEILING PLAN FOR LOCATIONS OF CUBICLE CURTAIN
TRACKS. PROVIDE CONT. BLOCKING ABOVE CEILING FOR CURTAIN TRACK ANCHORAGE.
9. SURFACE PREP: PREP SURFACES FOR NEW FINISHES ACCORDING TO SPECIFICATIONS AND
MANUFACTURERS RECOMMENDATIONS. PREPARE EXISTING WALLS TO REMAIN TO RECEIVE
NEW FINISH IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SEE EXTENT OF
EXISTING WALL TO REMAIN ON PLAN.
8. FURR OUT AROUND COLUMNS, PIPES, UTILITES, ETC., WITH THE MINIMUM DEPTH NECESSARY
TO CONCEAL PIPES.
7. WHERE DOOR IS SHOWN IN CORNER OF ROOM, LOCATE OUTSIDE EDGE OF DOOR FRAME 4"
FROM ADJACENT PERPENDICULAR WALL, (U.N.O.). ALLOW FOR PROTRUDING HARDWARE.
6. CUT AND PATCH EXISTING GYPSUM BOARD PARTITIONS TO CONCEAL ROUTING OF UTILITY
SERVICES, PIPES, ETC., UNLESS OTHERWISE PROHIBITED BY CODES.
5. BLOCKING: PROVIDE IN ALL WALLS WHERE REQUIRED FOR HANDRAILS, WALL GUARDS, FOR
SHELVING, WALL CABINETS, WALL MOUNTED DOOR STOPS AND EQUIPMENT. CUT AND PATCH
GYPSUM BOARD IN EXISTING WALLS FOR INSTALLATION OF NEW BLOCKING WHERE REQUIRED.
PROVIDE BLOCKING IN ALL WALLS AT WATER CLOSET LOCATIONS FOR GRAB BAR INSTALLATION
WHETHER GRAB BARS ARE INDICATED OR NOT. WOOD BLOCKING IS NOT ALLOWED.
4. RATED WALLS: INSURE WALLS INDICATED AS RATED FIRE AND / OR SMOKE BARRIERS ARE
CONTINUOUS CONSTRUCTION (THRU CORNERS AND TO THE DECK ABOVE) AND PENETRATIONS
ARE PROPERLY FIRE SEALED.
3. INSTALL ACOUSTICAL BATT INSULATION IN ALL INTERIOR PARTITIONS, (U.N.O.)
2. ALL PARTITIONS ARE TO BE CONTINUOUS TO THE STRUCTURE ABOVE, (U.N.O.)
1. VERIFY ALL DIMENSIONS/WORK TO BE DONE BASED ON EXISTING CONDITIONS. NOTIFY COR
IMMEDIATELY OF ANY CONFLICTS.
GENERAL ARCH. NOTES
0 4' 8' 12'
DENOTED BY A NUMBER ENCLOSED INSIDE A HEXAGON.
ONLY NOTES APPLICABLE TO THIS SHEET ARE SHOWN.
KEYNOTE SCHEDULE
01.01 MED-SURG SIM LAB TO BE SET UP LIKE A FUNCTIONING MED-SURG PATIENT ROOM.
PROVIDE PATIENT LIFT WITH UNISTRUT. PROVIDE NON-FUNCTIONING HEAD WALL WITH MED
GAS OUTLETS
04.66 USE SALVAGED BRICK FROM DEMOLITION FOR BRICK INFILL. MATCH THE COLOR OF THE
EXISTING MORTAR EVEN IF EXISTING MORTAR IS SLIGHTLY DISCOLORED. INFILL SHALL
MATCH THE EXISTING WALL CONSTURCITON.
05.01 REPLACE EXISTING EXPANSION JOINT. FACILITY STANDARD IS BELZONA SYSTEMS.
06.60 CASEWORK IN CREATIVE ARTS GROUP ROOM TO BE OF CORAIN FINISH. REF. ID SHEETS
FOR FINISH INFORMATION.
09.30 3/4" FIRE-REATARDENT PLYWOOD ALL WALLS THIS ROOM. PAINT TO MATCH WALL FINISH
09.82 MUSIC THERPY ROOMS SHALL BE COMPLETELY SEALED AT ALL SEAMS WITH ACOUSTICAL
SEALANT. ALL WALLS SHALL EXTEND UP TO THE UNDERSIDE OF THE STRUCTURAL DECK
AND SEALED.
10.01 ALTERNATING TREAD SHIPS LADDER
10.02 4'x8' WHITEBOARD VA PROVIDED AND INSTALLED. PROVIDE BLOCKING.
10.08 3' X 7' PASS DOOR ADA COMPLIANT WITH PANIC DEVICE AND SELF ILLUMINATED
NON-ELECTRIC EXIT SIGN IN DIRECTION OF EXIT ABOVE DOOR PART OF OPERABLE
PARTITIONS
10.09 MANUAL OPERABLE PARTITIONS WITH EGRESS DOOR SUPPORTED BY STRUCTURE ABOVE.
REF. CEILING PLANS AND STRUCTURAL DRAWING FOR MORE INFORMATION. BASIS OF
DESIGN MODERNFOLD ENCORE.
10.71 FIRE EXTINGUISHER CABINET (FEC), SEMI-RECESSED
10.81 A1030 - LOCKERS DOUBLE-TIER (12" X 12"),VA PROVIDED AND INSTALLED
10.90 CANOPY, ALUMINUNM, WITH INTERGAL DRAINAGE TO A SCUPPER AND DOWNSPOUT.
BRONZE ANODIZED FINISH, SUBMIT COLOR SAMPLE FOR FINAL VA SELECTION. PROVIDE
SUPPORT ON INTERIOR SIDE OF BUILDING TIED TO STRUCTURE FOR ANCHORAGE.BASIS OF
DESIGN: MAPES SUPER LUMIDECK. REMOVE BICK TO ANCHOR AWNING TO EXISTING CMU
WALL. REPLACE BRICK AS REQUIRED.
11.24 R7250 - REFRIGERATOR W/ FREEZER, VA PROVIDED AND INSTALLED
11.42 WALL MOUNTED PC. VA PROVIDED AND INSTALLED. CONTRACTOR TO PROVIDE BLOCKING
11.98 MEDICAL EQUIPMENT BOOM. BASIS OF DESIGN: STERIS HARMONYAIR UTILITY HUB. TWO
ARMS TO INCLUDE MONITOR AND HUB WITH ELECTRICAL, DATA, AND DUMMY MED GAS
OUTLETS REF. STRUCTURAL FOR SUPPORT.
11.99 MEDICAL EQUIPMENT BOOM. BASIS OF DESIGN: STERIS HARMONYAIR UTILITY HUB. TWO
ARMS TO INCLUDE SURGICAL LIGHT AND HUB WITH ELECTRICAL, DATA, AND DUMMY MED
GAS OUTLETS REF. STRUCTURAL FOR SUPPORT.
12.91 6' STAINLESS STEEL PREP TABLES - VA PROVIDED AND INSTALLED
22.01 SINK, SURGEON'S SCRUB, REF. PLUMBING
22.04 MOP SINK - CONTRACTOR PROVIDED AND INSTALLED
22.05 EMERGENCY EYEWASH STATION. REF. P-PI-02
22.07 SCULLERY SINK. REF. P-PI-02
22.11 DOUBLE COMPARTMENT DEEP SINK. REF. PLUMBING SCHEDULE
26.02 EXISTING ELECTRICAL ROOM TO REMAIN AS IS. COORDINATE ANY WORK IN THIS SPACE
WITH MEP DRAWINGS. ANY FINISHES THAT MAY BE DAMAGED AS A RESULT OF THE WORK
SHALL BE REPLACED AND REPAIRED TO ORIGINAL STATE.
27.02 IT/COMM ROOMS G-044 AND G-043 TO BE CONNECTED BEOFRE DEMOLITION BEGINS. SEE
SHEE T-TJ-01
I
I2
H3
G1
7.1 9.1
AE 05.01
AE 05.01
STAIR
100B
ROOF BELOW
A
E
.0
09.90 09.90
09.90
09.91
100C
AHU - 3
100A
01.07
01.07
1B
1B
1B
1B
MECH EQUIP PLATFORM 1
100A
MECH EQUIP PLATFORM 1
100B
PLUMBING
100D
100D
100E
H
17 18 19 22
F4
F1
AE 05.02
AE 05.02
MULTIPURPOSE ROOM BELOW
ROOF
20 21
E.5
F.3
16.5 17.4 17.5 18.8 18.9 20.1 20.2 21.3 21.5
4/ AE 04.01
07.52
AHU - 1
AHU - 2
1B
1B
1B
MECH EQUIP PLATFORM 2
D1
12.9
C.6
5/ AE 01.01C
A
E
.0
C
C
LE
A R
4' -0
5' -0 /2
CLEAR
5'-0"
05.40
6'-9"
'-0
03.20
'-6
10'-4"
CLEAR
3'-0"
19'-6"
05.40
EXISTING BRICK WALL BEYOND
5' -9
CLEAR
5'-0" 10'-4"
05.40
BRICK WALL BEYOND
54321
CORRIDOR TO BLDG 7
A A A A A A
AAA
G-061BA
G-061A
A
7/ AE 09.06
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/2
/2
:0
:4
P
M
AE 01.01C
MECH EQUIP
PLATFORMS/TRANSFORMER
TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA
REF: 2 / AE 01.01
1 EMLARGED MECH EQUIP PLATFORM 1 PLAN
0 4' 8' 12' 0 4' 8' 12'
REF: 3 / AE 01.01
2 ENLARGED MECH EQUIP PLATFORM 2 PLAN
● USE SEMI-GLOSS PAINT.
● LOCATE NOT MORE THAN 12'-0" O.C. ON CORRIDOR SIDES OF PARTITIONS, AND WITH A LEAST ONE MESSAGE PER ROOM ON ROOM SIDE OF PARTITION, AND WITHIN 15'-0" OF THE END OF EACH WALL.
● STENCIL MESSAGE SIMILAR TO: "SMOKE PARTITION" OR "1-HR FIRE BARRIER."
● IDENTIFY PARTITIONS ABOVE CEILINGS ON BOTH SIDES OF PARTITIONS EXCEPT WITHIN SHAFTS IN RED
LETTERS NOT LESS THAN 4" HIGH WITH AT LEAST A 3/8" STROKE.
12. FIRE AND SMOKE PARTITION / BARRIER IDENTIFICATION:
11. PENETRATIONS IN WALLS SHALL BE SEALED AS REQUIRED BY THE WALL RATING PER AN APPROVED UL
DESIGN.
10. GYPBOARD PANELS SHALL BE PLACED A MINIMUM OF 1/4" ABOVE FLOOR AND SHALL BE CUT WITHIN 1/4" MAX TOLERANCE TO SHAPE OF DECK OR STRUCTURE ABOVE. GAPS BETWEEN PANELS SHALL BE <1/4".
● PROVIDE DEFLECTION AND BRIDGING CLIPS.
● MAINTAIN CLEARANCE UNDER STRUCTURAL BUILDING MEMBERS TO AVOID DEFLECTION TRANSFER TO
STUDS. PROVIDE EXTENDED LEG CEILING RUNNERS.
9. DO NOT TRANSFER DEFLECTION FROM STRUCTURAL BUILDING MEMBERS TO STUDS. CONTRACTOR'S
OPTION, PROVIDE EITHER OF THE FOLLOWING:
8. EXTEND ALL WALL CONSTRUCTION TO THE DECK ABOVE AND SEAL U.N.O.
7. INSTALL ACOUSTICAL GASKETS AT FLOOR AND CEILING TRACK LOCATIONS.
6. PROVIDE ACOUSTICAL INSULATION FULL HEIGHT IN ALL WALLS U.N.O.
5. STAGGER JOINTS ON OPPOSITE SIDES OF PARTITIONS.
4. ALL FRAMING SHALL BE 20 GA U.N.O.
● PROVIDE FIRE RATED IMPACT RESISTANT GYPBOARD 4'-0"H ON ALL WALLS NOT SCHEDULED TO RECEIVE RIGID WALL PROTECTION, AND ADDITIONAL LOCATIONS AS NOTED ON DRAWINGS. (IMPACT RESISTANT GYPBOARD SHALL TAKE PRIORITY AT LOCATIONS INDICATED TO RECEIVE GLASS FIBER
FACED GYPSUM PANELS.)
● PROVIDE FIRE RATED GLASS FIBER FACED GYPSUM PANELS ON INTERIOR SURFACE OF EXTERIOR WALLS, TOILET ROOMS, JANITOR'S CLOSETS, MECHANICAL SPACES, AND WITHIN 4'-0" OF WATER...
● ALL GYPBOARD SHALL BE 5/8" TYPE 'X' U.N.O.
3. GYPBOARD REQUIREMENTS:
1. ALL WALLS SHALL BE 3-5/8" METAL STUD AT 16"0.C. MAX U.N.O.
REFERENCE WALL TYPE DETAILS, PLANS, AND SPECIFICATIONS.
GENERAL WALL NOTES
DENOTED BY A NUMBER ENCLOSED INSIDE A HEXAGON.
ONLY NOTES APPLICABLE TO THIS SHEET ARE SHOWN.
KEYNOTE SCHEDULE
01.07 WALL INFILL TO MATCH 1 HR RATING OF ADJACENT WALL. WALL SHOULD BE FINSIHES
FLUSH WITH EXISTING WALL
03.20 NEW CONCRETE SLAB FOR TRANSFORMER RELOCATION. COORDINATE FINAL SIZE WITH
TRANSFORMER
05.40 METAL PANEL WALL SCREEN AROUND TRANSFORMER PAD. PANEL TO BE HELD OFF FINISH
GRADE 12". BASIS OF DESIGN: INDUSTRIAL LOUVERS, INC. MODEL 450XPI, COLOR TO BE
MEDIUM BRONZE. SUBMIT COLOR SAMPLE TO COR FOR FINAL APPROVAL.
07.52 ROOFING MEMBRANE WALK PATH. COORDINATE PATH WITH EXISTING ROOF EXHAUST
VENTS.
09.90 EXISTIN CMU WALL TO REMAIN SHALL BE CLEANED AND PAINTED
09.91 EXISTING FLOORING TO BE CLEANED
REF: 1 / AE 01.01A
4 TRANSFORMER PLAN
REF: 1 / AE 01.01A
6 TRANSFORMER
REF: 1 / AE 01.01A
5 TRANSFORMER
0 4' 8' 12'
0 4' 8' 12'
0 4' 8' 12'
3 GROUND FLOOR - CORRIDOR TO BLDG. 7
.0
SCUPPER SCUPPER SCUPPER SCUPPER
SCUPPER SCUPPER
A
E
.0
3/ AE 04.02
4/ AE 04.02
7/ AE 04.02
5/ AE 04.02
AE 01.02
AE 01.02
10.91
EXISTING RTU
EXISTING
EXPANSION JOINT
TO REMAIN
R
ID
G E
RIDGE
R
ID
G E
2/ AE 04.01
4/ AE 04.01
A
E
.0
A
E
.0
10.91
22.19
22.19…