This document provides structural notes and details for the construction of an integrated health center in Murfreesboro, Tennessee under solicitation number 36C77623B0037. Key information includes specifications for reinforced concrete foundations including drilled piers and grade beams, structural steel framing for floors and roofing, and notes on composite metal decking and concrete slabs. Foundation details cover requirements for pile caps, drilled pier schedules, and grade beam schedules. Additional sections specify requirements for columns, base plates, slab construction joints, slab repairs for trenching, and exterior slab and grade beam details.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CODES AND STANDARDS:
1. 2018 INTERNATIONAL BUILDING CODE
2. AMERICAN CONCRETE INSTITUTE, "BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE" (ACI 318)
3. AMERICAN CONCRETE INSTITUTE, "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR
BUILDINGS" (ACI 301) LATEST ADOPTED EDITION.
4. AMERICAN INSTITUTE OF STEEL CONSTRUCTION, "SPECIFICATIONS FOR THE DESIGN,
FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" 13TH EDITION.
5. STEEL DECK INSTITUTE, "DESIGN MANUAL FOR COMPOSITE DECKS, FORM
DECKS, AND ROOF DECKS."
6. STEEL JOIST INSTITUTE, "STANDARD SPECIFICATIONS; LOAD AND WEIGHT TABLES FOR
OPEN WEB STEEL JOIST."
7. AMERICAN WELDING SOCIETY, "STRUCTURAL WELDING CODE AWS D1.1."
DESIGN LIVE LOADS:
1. ROOF GRAVITY LOAD_________________20 PSF
2. MECHANICAL ROOM__________________125 PSF
SEISMIC DESIGN DATA:
Ss = 0.246 Sds = 0.213 S1 = 0.124 Sd1 = 0.124
SITE CLASSIFICATION = C
OCCUPANCY CATEGORY = II
SEISMIC DESIGN CATEGORY = B
BASIC STRUCTURAL SYSTEM = CANTILEVERED COLUMN SYSTEM (AT NEW CONST.)
SEISMIC RESISTING SYSTEMS = STEEL ORDINARY CANTILEVER COLUMN SYSTEM
RESPONSE MODIFICATION FACTOR R = 1.25
DEFLECTION AMPLIFICATION FACTOR Cd = 1.25
FOUNDATIONS:
1. FOUNDATION DESIGN IS BASED ON RECOMMENDATIONS CONTAINED IN THE SOILS REPORT
BY S&ME DATED JAN 3, 2019 AND INFORMATION FROM EXISTING BUILDING 107
CONSTRUCTION DRAWINGS. THE DESIGN PARAMETERS ARE:
A. DRILLED PIER ALLOWABLE ROCK BEARING CAPACITY_____________100,000 PSF
B. STRIP FOOTING BEARING PRESSURE (AT WALLS, ETC.)______________2,000 PSF
C. SITE GRADING:
a. ALL ORGANIC MATERIAL SHALL BE STRIPPED
b. EXPOSED SUBGRADE SHALL BE PROOFROLLED TO DETECT SOFT AREAS
c. PROOFROLLING SHALL BE DONE WITH A HEAVILY LOADED DOUBLE AXLE DUMPTRUCK
AND OBSERVED BY A GEOTECHNICAL ENGINEER
d. WHERE SOFT AREAS, ORGANIC MATERIAL, OR HIGHLY PLASTIC CLAYS ARE
ENCOUNTERED DURING THE PROOFROLLING, THE AREA SHALL BE UNDERCUT AND
REPLACED WITH COMPACTED ENGINEERED FILL PLACED IN LAYERS NOT TO EXCEED
8". THIS FILL SHALL BE COMPACTED TO A MINIMUM OF 98% STANDARD PROCTOR
DENSITY (ASTM D-698) .
e. WHERE SUBGRADE NEEDS TO BE FILLED TO REACH PROPOSED SUBGRADE LEVEL, ENGINEERED FILL SHALL BE PLACED IN LAYERS NOT TO EXCEED 8". THIS FILL SHALL
BE COMPACTED TO A MINIMUM OF 98% STANDARD PROCTOR DENSITY (ASTM D-698)
2. THE FOOTING EXCAVATIONS SHALL BE MADE IN NEAT LINES AND SHALL BE FREE OF
LOOSE OR WET MATERIALS. CONCRETE MAY BE PLACED DIRECTLY AGAINST THE SOIL
WITHOUT FORMING. EXCAVATIONS ADJACENT TO EXISTING FOUNDATION SHALL NOT
UNDERMINE FOUNDATIONS. PROVIDE SHORING AS REQUIRED WHERE EXCAVATIONS
CREATE UNBALANCED FILL CONDITION.
3. FOOTINGS SHALL BE INSPECTED BY A SOILS ENGINEER PRIOR TO PLACING CONCRETE IN
ORDER TO ENSURE THAT THE BEARING SURFACES ARE CONSISTENT WITH DESIGN
RECOMMENDATIONS.
4. WHERE SOFT AREAS ARE ENCOUNTERED, THE AREA SHALL BE UNDERCUT AS REQUIRED
AND REPLACED WITH COMPACTED FILL OR CONCRETE. THE FILL SHALL BE PLACED IN
LAYERS NOT TO EXCEED 8" AND SHALL BE COMPACTED TO A MINIMUM OF 98% STANDARD
PROCTOR DENSITY (ASTM D-698).
5. FLOOR DRAINS HAVE NOT BEEN SHOWN ON THE FOUNDATION PLAN. FLOORS SHALL BE
SLOPED TO DRAINS IN ACCORDANCE WITH THE REQUIREMENTS OF THE ARCHITECTURAL
AND PLUMBING DRAWINGS.
6. DEPTH OF ROCK SHOWN IS FOR BIDDING PURPOSES ONLY AND MAY VARY ACCORDING TO
THE ACTUAL FIELD CONDITIONS.
7. THE CONTRACTOR SHALL VERIFY DEPTHS OF PIERS BEFORE PIER STEEL IS CUT. PIER
STEEL SHALL BE DELIVERED TO THE JOB SITE IN STOCK LENGTHS
AND CUT AS REQUIRED.
8. BEARING STRATA SHOWN ON THE PIER DETAIL IS LIMESTONE.
9. MINIMUM PENETRATION INTO THE BEARING STRATA SHALL BE 2'-0".
10. DUE TO THE PRESENCE OF GROUND WATER AND/OR CAVING SOILS, CASING OF SOILS
MAY BE REQUIRED.
11. CONCRETING OF INDIVIDUAL PIERS SHALL BE COMPLETED WITHIN 8 HOURS OF DRILLING.
12. THE CONTRACTOR SHALL MAKE ACCURATE MEASUREMENTS OF THE DEPTH OF
PENETRATION INTO THE BEARING STRATA TO BE ASSURED OF CONFORMANCE WITH THE
DEPTH OF PENETRATION REQUIRED AND SUBMIT A REPORT OF THE DEPTH OF
PENETRATION DRILLED TO THE ENGINEER.
13. GEOTECHNICAL ENGINEER SHALL INSPECT AND TEST EACH DRILLED PIER BEARING
SURFACE BY DRILLING AND PROBING A MINIMUM OF ONE PERCUSSION HOLE
(2" DIA.x 6'-0" DEEP) PER DRILLED PIER.
CONCRETE:
1. DETAILS OF EACH PROPOSED CONCRETE MIX SHALL BE SUBMITTED AND REVIEWED PRIOR
TO PLACING CONCRETE OF THAT MIX IN ACCORDANCE WITH CHAPTER 5 OF ACI 318-89R92
2. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS AS FOLLOWS:
A. FOOTINGS_____________________________3500 PSI
B. INTERIOR SLAB ON GRADE_______________3500 PSI
C. EXTERIOR CONCRETE___________________4000 PSI
D. WALLS_________________________________4000 PSI
E. STRUCTURAL SLABS_____________________4000 PSI
3. ALL REINFORCING STEEL SHALL BE DOMESTIC BILLET STEEL CONFORMING TO ASTM A-615, GRADE 60 (60,000 PSI YIELD POINT) EXCEPT THAT #3 BARS MAY BE ASTM A-615, GRADE 40
(40,000 PSI YIELD POINT).
4. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-1064.
5. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI STANDARD "BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE", ACI 318 LATEST REVISION.
6. CONCRETE SHALL BE TESTED IN ACCORDANCE WITH AND AT THE FREQUENCY SPECIFIED
IN ACI 318, LATEST REVISION. ONE SLUMP TEST AND ONE AIR ENTRAINMENT SHALL BE
TAKEN FOR EACH SET OF TEST CYLINDERS TAKEN AS WELL AS THE TEMPERATURE
RECORDED. (NOTE THAT WATER SHALL NOT BE ADDED AT THE JOB SITE ALTERING THE
APPROVED MIX DESIGN)
7. REINFORCING BARS SHALL BE DETAILED AND BAR SUPPORTS AND SPACERS PROVIDED IN
ACCORDANCE WITH THE ACI DETAILING MANUAL (ACI-315) AND MANUAL OF STANDARD
PRACTICE BY THE CONCRETE REINFORCING STEEL INSTITUTE.
8. GRADE BEAM REINFORCEMENT SHALL BE CONTINUOUS WHERE POSSIBLE. SPLICE BOTTOM
BARS AT CENTERLINE OF SUPPORT AND SPLICE TOP BARS AT CENTERLINE OF SPAN.
MINIMUM LAP DIMENSIONS SHALL BE 30 BAR DIAMETERS WITH 2'-0" MINIMUM FOR TOP AND
BOTTOM REINFORCING AT MID-SPAN AND SUPPORT LOCATIONS RESPECTIVELY. ALL
OTHER LAP SPLICES SHALL BE LAP TENSION SPLICES(LTS).
9. PROVIDE CORNER BARS FOR BARS MEETING AT INTERSECTIONS. SIZE AND NUMBER OF
CORNER BARS SHALL BE EQUAL TO THE LARGER OF THE BAR INTERSECTING. MINIMUM LAP
DIMENSIONS SHALL BE 30 BAR DIAMETERS WITH 2'-0" MINIMUM.
10. REFERENCE ARCHITECTURAL AND MECHANICAL PLANS FOR VERIFICATION OF CAST-IN-
PLACE BOLTS, INSERTS, ANCHORS, SLAB LEAVE-OUTS, SLOPES, AND DEPRESSIONS.
11. SHOP DRAWINGS SHALL BE SUBMITTED PRIOR TO FABRICATION. REINFORCING BARS
SHALL BE DETAILED AND BAR SUPPORTS AND SPACERS PROVIDED IN ACCORDANCE WITH
THE ACI DETAILING MANUAL(ACI-315) AND MANUAL OF STANDARD PRACTICE BY THE
CONCRETE REINFORCING STEEL INSTITUTE.
12. MINIMUM LAP DIMENSIONS SHALL BE 48 BAR DIAMETERS WITH 2'-0" MINIMUM UNLESS
NOTED OTHERWISE.
13. CLEAR CONCRETE COVER FOR REINFORCING BARS:
FOOTINGS_____________________2" FORMED EDGES
FOOTINGS_____________________3" CAST AGAINST EARTH
GRADE BEAMS AND PIERS_______2"
BELOW GRADE WALLS__________2" EXTERIOR FACE
BELOW GRADE WALLS__________3/4" INTERIOR FACE
ABOVE GRADE WALLS__________3/4" BOTH FACES
BEAMS______________________1-1/2"
SLABS________________________3/4"
MASONRY WALLS______________CENTER OF WALL (U.N.O.)
14. ALL CONCRETE SHALL BE VIBRATED WITH MECHANICAL VIBRATORS.
STRUCTURAL STEEL:
1. STRUCTURAL STEEL W-SHAPES SHALL CONFORM TO ASTM A-992. STRUCTURAL STEEL M, S,
AND CHANNEL SHAPES SHALL CONFORM TO ASTM A572 GRADE 50 STRUCTURAL STEEL
ANGLES AND MISCELLANEOUS PLATES, ETC. SHALL CONFORM TO ASTM A-36 UNLESS
NOTED OTHERWISE ON THE PLANS. ANCHOR BOLTS SHALL BE ASTM F1554, GRADE 36
UNLESS NOTED OTHERWISE ON THE PLANS.
2. PIPE COLUMNS SHALL CONFORM TO ASTM A-53, GRADE B.
3. HOLLOW STEEL SECTIONS (HSS) SHALL CONFORM TO ASTM A-500, GRADE B.
4. STRUCTURAL STEEL SHALL CONFORM TO AISC "SPECIFICATIONS FOR THE DESIGN,
FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" 13TH EDITION.
5. WELDED CONNECTIONS SHALL CONFORM TO THE AMERICAN WELDING SOCIETY
SPECIFICATIONS AND REQUIREMENTS, LATEST REVISIONS, E70XX ELECTRODES. ALL
WELDING SHALL COMPLY WITH THE "STRUCTURAL WELDING CODE" OF THE AWS D1.1.
6. STRUCTURAL BOLTS, NUTS, AND CIRCULAR WASHERS AND JOINTS SHALL CONFORM TO
ASTM A325. USE BEARING-TYPE BOLTS WITH THREAD ALLOWED ACROSS THE SHEAR
PLANE.
7. PLATE SIZES, ANGLE SIZES, NUMBER AND SIZE OF BOLTS AND OR WELDS FOR
CONNECTIONS SHALL BE DESIGNED BY THE CONTRACTOR IN ACCORDANCE WITH THE
REQUIREMENTS OF PART 10 OF THE 13TH EDITION OF THE AISC MANUAL FOR THE SHEAR.
USE 55% OF THE TOTAL LOAD SHOWN IN THE BEAM TABLES IN PART 3 OF THE 13TH
EDITION OF THE AISC CODE FOR THE GIVEN BEAM SPAN AND STEEL GRADE FOR NON-
COMPOSITE BEAMS. USE THE REACTIONS AS SPECIFIED ON THE DRAWINGS FOR
COMPOSITE BEAMS.
8. ALL STEEL EXPOSED TO EXTERIOR ELEMENTS SHALL BE GALVANIZED.
9. NO SHOP OR FIELD SPLICES SHALL BE ALLOWED IN ANY BEAMS, GIRDERS, OR COLUMNS AT
LOCATIONS OTHER THAN THOSE SHOWN ON THE DRAWINGS.
10. STEEL JOISTS AND JOIST GIRDERS SHALL CONFORM TO THE REQUIREMENTS OF THE AISC
STANDARD SPECIFICATION FOR OPEN WEB JOIST "K" OR "LH" SERIES. STEEL JOIST
MANUFACTURER SHALL BE A MEMBER OF THE STEEL JOIST INSTITUTE. MATERIAL SHALL BE
DOMESTIC STEEL. JOISTS SHALL BE FABRICATED WITH MINIMUM CAMBER AS
RECOMMENDED BY THE STEEL JOIST INSTITUTE.
11. PROVIDE BOTTOM CHORD (CEILING) EXTENSIONS ON ALL JOIST WHERE INDICATED.
REFERENCE ARCHITECTURAL PLANS FOR DETAILS.
12. HANGERS TO SUPPORT MECHANICAL EQUIPMENT, ETC., SHALL BE LOCATED AT PANEL
POINTS OF THE JOIST.
13. VERIFY EXACT SIZE AND LOCATION OF MECHANICAL OPENINGS WITH EQUIPMENT TO BE
USED.
14. ANY DEVIATION FROM, ADDITION TO, SUBSTITUTION FOR, OR MODIFICATION TO THE
STRUCTURE OR ANY PART OF THE STRUCTURE DETAILED ON THESE CONTRACT
DOCUMENTS SHALL BE SUBMITTED, IN WRITING, TO THE ENGINEER FOR HIS REVIEW.
SHOP DRAWINGS THAT ARE SUBMITTED TO THE ENGINEER FOR HIS REVIEW DO NOT
CONSTITUTE "IN WRITING" UNLESS IT IS BROUGHT TO THE ATTENTION OF THE ENGINEER
THAT SPECIFIC CHANGES ARE BEING SUGGESTED.
15. SEE SERIES OF SHEETS LABELED S4 FOR TYPICAL DETAILS LABELED AS SUCH AND NOT
REFERRED TO EXCEPT HEREIN. OBSERVE ALL THE REQUIREMENTS OF THESE DETAILS TO
THE SAME EXTENT AS THAT GIVEN TO ALL OTHER DETAILS.
16. UNLESS NOTED OTHERWISE, STEEL BEAMS SHALL BEAR 16" ON MASONRY AND BE
ANCHORED WITH 2- 3/4" DIAMETER ROUND ANCHOR BOLTS.
17. ALL EPOXY ANCHORS INTO CMU OR CONCRETE SHALL BE HILTI HIT HY 200 ADHESIVE
ANCHORS (OR EQUAL) UNLESS SPECIFICALLY NOTED OTHERWISE ON THE STRUCTURAL
DRAWINGS. NOTE THAT ANCHORS INTO CMU SHALL BE LOCATED AT EITHER VERTICALLY
GROUTED CELLS OR AT HORIZONTAL BOND BEAMS. ADHESIVE ANCHOR INSTALLERS SHALL
BE CERTIFIED BY THE ACI/CRSI CERTIFICATION PROGRAM.
18. REFERENCE PERFORMANCE SPECIFICATION FOR STEEL PAN STAIRS AND SHIPS LADDER.
SUBMIT SHOP DRAWINGS FOR A/E REVIEW SIGNED AND SEALED BY A REGISTERED
STRUCTURAL ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED.
STRUCTURAL QUALITY ASSURANCE PLAN:
THIS STRUCTURAL QUALITY ASSURANCE PLAN IDENTIFIES THE RESPONSIBILITIES OF THE
CONTRACTOR AND THE SPECIAL INSPECTOR IN PERFORMING THE TESTING AND INSPECTION
OF THE WORK REQUIRED BY CHAPTER 17 OF THE BUILDING CODE THAT IS WITHIN THE
SCOPE OF THE STRUCTURAL ENGINEERING SERVICES FOR THIS PROJECT. REFER TO OTHER
PORTIONS OF THE CONSTRUCTION DOCUMENTS FOR TESTING AND INSPECTIONS REQUIRED
OF ARCHITECTURAL, MECHANICAL, ELECTRICAL, OR OTHER BUILDING COMPONENTS.
CONTRACTOR RESPONSIBILITIES
THE CONTRACTOR SHALL SUBMIT TO THE BUILDING OFFICIAL AND THE ARCHITECT A
WRITTEN STATEMENT OF RESPONSIBILITY THAT CONTAINS THE FOLLOWING:
1. ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED
WITHIN THIS STRUCTURAL QUALITY ASSURANCE PLAN.
2. ACKNOWLEDGEMENT THAT CONTROL SHALL BE EXERCISED TO OBTAIN CONFORMANCE
WITH THE CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING OFFICIAL.
3. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION,
THE METHOD AND FREQUENCY OF REPORTING, AND THE DISTRIBUTION OF REPORTS.
4. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) EXERCISING SUCH CONTROL
AND THEIR POSITION(S) IN THE ORGANIZATION.
THE STRUCTURAL TESTING/INSPECTION AGENCY THAT IS TO ACT AS THE SPECIAL
INSPECTOR WILL BE HIRED BY THE OWNER.
CONTRACTOR SHALL PAY FOR ADDITIONAL STRUCTURAL TESTING/INSPECTION REQUIRED
FOR WORK OR MATERIALS NOT COMPLYING WITH THE CONSTRUCTION DOCUMENTS DUE TO
NEGLIGENCE OR NONCONFORMANCE AND SHALL PAY FOR ADDITIONAL STRUCTURAL
TESTING/INSPECTION REQUIRED FOR HIS CONVENIENCE.
CONTRACTOR IS RESPONSIBLE TO ENSURE THAT THE SPECIAL INSPECTOR IS PRESENT FOR
ALL WORK REQUIRING SPECIAL INSPECTION. ANY WORK THAT REQUIRES SPECIAL
INSPECTION AND IS PERFORMED WITHOUT THE SPECIAL INSPECTOR BEING PRESENT IS
SUBJECT TO BEING DEMOLISHED AND RECONSTRUCTED.
CONTRACTOR HAS THE FOLLOWING RESPONSIBILITIES TO THE SPECIAL INSPECTOR:
1. PROVIDE COPY OF CONSTRUCTION DOCUMENTS TO THE SPECIAL INSPECTOR.
2. NOTIFY THE SPECIAL INSPECTOR SUFFICIENTLY IN ADVANCE OF OPERATIONS TO ALLOW
ASSIGNMENT OF PERSONNEL AND SCHEDULING OF TESTS.
3. COOPERATE WITH SPECIAL INSPECTOR AND PROVIDE ACCESS TO WORK.
4. PROVIDE SAMPLES OF MATERIALS TO BE TESTED IN REQUIRED QUANTITIES.
5. PROVIDE STORAGE SPACE FOR THE SPECIAL INSPECTOR'S EXCLUSIVE USE, SUCH AS FOR
STORING AND CURING CONCRETE TESTING SAMPLES.
6. PROVIDE LABOR TO ASSIST THE SPECIAL INSPECTOR IN PERFORMING
TESTS/INSPECTIONS.
SPECIAL INSPECTOR RESPONSIBILITIES
SPECIAL INSPECTOR SHALL MAINTAIN RECORDS OF INSPECTIONS IN ACCORDANCE WITH
CHAPTER 17 OF THE BUILDING CODE AND SHALL DISTRIBUTE THESE RECORDS TO THE
BUILDING OFFICIAL, ARCHITECT, AND STRUCTURAL ENGINEER ON A WEEKLY BASIS. AT THE
CONCLUSION OF THE PROJECT THE SPECIAL INSPECTOR SHALL SUBMIT A WRITTEN
STATEMENT THAT THE SPECIAL INSPECTIONS DURING CONSTRUCTION HAVE COMPLIED
WITH THIS STRUCTURAL QUALITY ASSURANCE PLAN AND THAT ANY DISCREPANCIES NOTED
DURING CONSTRUCTION HAVE BEEN CORRECTED.
DRILLED PIERS:
SPECIAL INSPECTOR SHALL PERFORM THE FOLLOWING:
1. PROVIDE CONTINUOUS INSPECTION OF DRILLING PROCESS
2. PROVIDE CONCRETE SAMPLING/TESTING AS REQUIRED IN "CAST-IN-PLACE CONCRETE"
HEADING OF THESE NOTES.
3. PROVIDE DRILLED PIER REPORT FOR EACH DRILLED PIER THAT INCLUDES THE FOLLWING:
A. ACTUAL TOP AND BOTTOM ELEVATIONS
B. TOP OF ROCK ELEVATION
C. DESCRIPTION OF SOIL MATERIALS
D. DESCRIPTION, LOCATION, AND DIMENSIONS OF OBSTRUCTIONS
E. FINAL TOP CENTERLINE LOCATIONS AND DEVIATIONS FROM REQUIREMENTS
F. VARIATION OF SHAFT FROM PLUMB
G. SHAFT EXCAVATING METHOD
H. INSPECT AND TEST EACH PIER BEARING SURFACE (BY DRILLING AND PROBING A
MINIMUM OF ONE PERCUSSION DRILLED HOLE TO A DEPTH OF NOT LESS THAN 6'-0" AT
EACH PIER BEARING)
I. DEPTH OF ROCK SOCKET
J. LEVELNESS OF BOTTOM AND ADEQUACY OF CLEANOUT
K. GROUNDWATER CONDITION AND WATER INFILTRATION RATE, DEPTH, AND PUMPING
L. DESCRIPTION, DIAMETER, AND TOP AND BOTTOM ELEVATIONS OF TEMPORARY OR
PERMANENT CASING
M. DESCRIPTION OF SOIL OR WATER MOVEMENT , SIDEWALL STABILITY, LOSS OF GROUND,
AND MEANS OF CONTROL
N. DATE AND TIME OF STARTING AND COMPLETING EXCAVATION
O. POSITION OF REINFORCING STEEL, CONFIRMING SIZE, QUANTITY, SPACING, AND
LENGTH
P. CONCRETE PLACING METHOD, INCLUDING ELEVATION OF CONSOLIDATION AND DELAYS
Q. ELEVATION OF CONCETE DURING REMOVAL OF CASINGS
R. LOCATION OF CONSTRUCTION JOINTS
S. REMARKS, UNUSUAL CONDITIONS ENCOUNTERED, AND DEVIATIONS FROM
REQUIREMENTS
T. CONCRETE TESTING RESULTS
SOIL:
SPECIAL INSPECTOR SHALL PERFORM THE FOLLOWING:
1. VERIFY STRUCTURAL FILL COMPLIES WITH THE PROJECT SPECIFICATIONS AND THE
GEOTECHNICAL REPORT.
2. OBSERVE PROOF-ROLLING AND UNDERCUTTING WHERE REQUIRED.
3. OBSERVE AND VERIFY THAT PLACEMENT OF STRUCTURAL FILL COMPLIES WITH THE
PROJECT SPECIFICATIONS AND THE GEOTECHNICAL REPORT.
4. PERFORM FIELD DENSITY TESTS TO VERIFY COMPACTION OF STRUCTURAL FILL. AS A
MINIMUM, PERFORM ONE TEST PER LIFT FOR EVERY 2,500 SQUARE FEET OF FILL PLACED.
5. VERIFY FOUNDATION BEARING CAPACITY.
CAST-IN-PLACE CONCRETE
CONTRACTOR SHALL PERFORM THE FOLLOWING:
1. SUBMIT MILL TEST REPORTS.
2. SUBMIT MANUFACTURER'S DATA FOR TENSILE AND COMPRESSIVE SPLICERS.
3. ESTABLISH CONCRETE MIX DESIGN PROPORTIONS PER ACI 318, CHAPTER 5. SUBMIT
THREE COPIES OF THE CONCRETE MIX DESIGNS. INCLUDE THE FOLLOWING:
A. TYPE AND QUANTITIES OF MATERIALS.
B. SLUMP
C. AIR CONTENT
D. FRESH UNIT WEIGHT
E. AGGREGATES SIEVE ANALYSIS
F. DESIGN COMPRESSIVE STRENGTH
G. LOCATION OF PLACEMENT IN STRUCTURE
H. METHOD OF PLACEMENT
I. METHOD OF CURING
J. SEVEN-DAY AND 28-DAY COMPRESSIVE STRENGTHS
4. SUBMIT A CERTIFICATION FROM EACH MANUFACTURER OR SUPPLIER STATING THAT
MATERIALS MEET THE REQUIREMENTS OF THE SPECIFIED ASTM AND ACI STANDARDS.
5. SUBMIT CERTIFICATION THAT THE READY-MIXED CONCRETE PLAN COMPLIES WITH THE
REQUIREMENTS OF THE NATIONAL READY MIX CONCRETE ASSOCIATION.
SPECIAL INSPECTOR SHALL PERFORM THE FOLLOWING:
1. VERIFY GRADE, QUANTITY, LOCATION, AND PLACEMENT OF REINFORCING STEEL PRIOR TO
CONCRETE PLACEMENT.
2. EXAMINE CONCRETE IN TRUCK TO VERIFY THAT CONCRETE APPEARS PROPERLY MIXED.
3. PERFORM A SLUMP TEST AS DEEMED NECESSARY FOR EACH CONCRETE LOAD. RECORD IF
WATER OR ADMIXTURES ARE ADDED TO THE CONCRETE AT THE JOB SITE. PERFORM
ADDITIONAL SLUMP TESTS AFTER JOB SITE ADJUSTMENTS.
4. MOLD FOUR SPECIMENS PER SET FOR COMPRESSIVE STRENGTH TESTING; ONE SET FOR
EACH 75 CUBIC YARDS OF EACH MIX DESIGN PLACED IN ANY ONE DAY. FOR EACH SET
MOLDED, RECORD:
A. SLUMP
B. AIR CONTENT
C. UNIT WEIGHT
D. TEMPERATURE, AMBIENT AND CONCRETE
E. LOCATION OF PLACEMENT
F. ANY PERTINENT INFORMATION, SUCH AS ADDITION OF WATER, ADDITION OF
ADMIXTURES, ETC.
PERFORM ONE 7-DAY AND TWO 28-DAY COMPRESSIVE STRENGTH TESTS. (USE ONE AS
A SPARE TO BE BROKEN AS DIRECTED BY THE STRUCTURAL ENGINEER IF COMPRESSIVE
STRENGTHS DO NOT APPEAR ADEQUATE.
5. REPORTS OF COMPRESSIVE STRENGTH TESTS SHALL CONTAIN THE PROJECT
IDENTIFICATION NAME AND NUMBER, DATE OF CONCRETE PLACEMENT, NAME OF
CONCRETE TESTING AGENCY, CONCRETE DESIGN COMPRESSIVE STRENGTH, LOCATION
OF CONCRETE PLACEMENT IN STRUCTURE, CONCRETE MIX PROPORTIONS AND
MATERIALS, COMPRESSIVE BREAKING STRENGTH AND TYPE OF BREAK.
6. VERIFY THE DRY WEIGHT OF THE LIGHTWEIGHT AGGREGATES AND THE FIVE-DAY
SATURATED WEIGHT OF THE AGGREGATE, AND VERIFY THAT AGGREGATES ARE BEING
PROPERLY PRESOAKED PRIOR TO BATCHING CONCRETE.
7. MONITOR PLACEMENT OF STRUCTURAL LIGHTWEIGHT CONCRETE PLACED BY PUMPING.
NON-SHRINK GROUT UNDER STEEL BASE PLATES
SPECIAL INSPECTOR SHALL PERFORM THE FOLLOWING:
1. COMPRESSIVE STRENGTH TESTS PER ASTM C109.
2. NUMBER OF TESTS: ONE TEST FOR EACH TEN BAGS OF GROUT USED OR MINIMUM OF ONE
TEST FOR EACH DAY OF GROUTING.
3. CUBE SIZE: 2-INCH X 2-INCH.
4. TEST SCHEDULE: ONE CUBE AT 3 DAYS, TWO CUBES AT 7 DAYS, THREE CUBES AT 28 DAYS.
STRUCTURAL STEEL
CONTRACTOR SHALL PERFORM THE FOLLOWING:
1. SUBMIT CERTIFICATION THAT THE FABRICATOR IS REGISTERED AND APPROVED BY THE
BUILDING OFFICIAL TO PERFORM REQUIRED WORK WITHOUT SPECIAL INSPECTIONS.
2. IF FABRICATOR IS NOT REGISTERED AND APPROVED, SPECIAL INSPECTION OF THE
FABRICATED ITEMS SHALL BE REQUIRED. SPECIAL INSPECTOR SHALL VERIFY THAT THE
FABRICATOR MAINTAINS DETAILED FABRICATION AND QUALITY CONTROL PROCEDURES
THAT PROVIDE A BASIS FOR INSPECTION CONTROL OF THE WORKMANSHIP AND THE
FABRICATOR'S ABILITY TO CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND
REFERENCED STANDARDS. SPECIAL INSPECTOR SHALL REVIEW THE PROCEDURES FOR
COMPLETENESS AND ADEQUACY RELATIVE TO THE CODE REQUIREMENTS FOR THE
FABRICATOR'S SCOPE OF WORK.
3. SUBMIT CERTIFIED MILL TEST REPORTS FOR STRUCTURAL STEEL.
4. SUBMIT MANUFACTURER'S CERTIFICATE OF COMPLIANCE FOR HIGH-STRENGTH BOLTING
AND WELD FILLER MATERIALS.
SPECIAL INSPECTOR SHALL PERFORM THE FOLLOWING:
1. INSPECTION OF THE STEEL FRAME TO VERIFY COMPLIANCE WITH THE DETAILS SHOWN ON
THE APPROVED CONSTRUCTION DOCUMENTS INCLUDING MEMBER LOCATIONS, BRACING,
CONNECTION DETAILS, ETC.
2. PROVIDE CONTINUOUS INSPECTION TO VERIFY COMPLIANCE OF THE FOLLOWING:
A. COMPLETE AND PARTIAL PENETRATION GROOVE WELDS. ULTRASONICALLY INSPECT
100% OF THE COMPLETE PENETRATION WELDS.
B. MULTI-PASS FILLET WELDS AND SINGLE-PASS FILLET WELDS GREATER THAN 5/16".
3. PROVIDE PERIODIC INSPECTION TO VERIFY COMPLIANCE OF THE FOLLOWING:
A. MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS, NUTS, AND WASHERS.
B. MATERIAL VERIFICATION OF WELD FILLER MATERIAL.
C. VERIFICATION OF ANCHOR ROD SIZE, CONFIGURATION, AND EMBEDMENT PRIOR TO
PLACEMENT OF CONCRETE.
D. VISUALLY INSPECT ALL BOLTED CONNECTIONS IN ACCORDANCE WITH AISC
SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS. PRIOR TO
VISUAL AND PHYSICAL TESTING, TENSION TESTING USING A CALIBRATION DEVICE
(SKIDMORE-WILHELM) MUST INDICATE TENSIONS AT LEAST 5% IN EXCESS OF THE AISC
MINIMUM. STRUCTURAL STEEL ERECTOR SHALL SUPPLY THE TENSION CALIBRATION
DEVICE. TEST A MINIMUM OF 10% OF THE BOLTED CONNECTIONS.
E. VISUALLY INSPECT ALL FIELD-WELDED CONNECTIONS. VISUAL INSPECTION OF WELDED
JOINTS INCLUDES PERIODIC EXAMINATION OF FITUP.
F. VERIFY STUD SHEAR CONNECTOR SPACING AND LOCATIONS. VISUALLY INSPECT
WELDING OF STUD SHEAR CONNECTORS.
4. WELD INSPECTIONS TO INCLUDE THE FOLLOWING:
A. WELD INSPECTIONS SHALL BE IN ACCORDANCE WITH AWS D1.1.
B. REVIEW AND VERIFY COMPLIANCE OF WRITTEN WELDING PROCEDURES WITH AWS
REQUIREMENTS.
C. VERIFY THAT WELDING PROCEDURES ARE BEING ADHERED TO DURING FIELD WELDING.
D. VERIFY WELDER QUALIFICATIONS.
E. USE ALL MEANS NECESSARY TO DETERMINE THE QUALITY OF WELDS. THE INSPECTOR
MAY USE GAMMA RAY, MAGNAFLUX, TREPANNING, SONICS OR ANY OTHER AID TO
VISUAL INSPECTION THAT THE SPECIAL INSPECTOR MAY DEEM NECESSARY TO BE
ASSURED OF THE ADEQUACY OF THE WELDING.
F. KEEP A SYSTEMATIC RECORD OF ALL WELDS THAT INCLUDES, IN ADDITION TO OTHER
REQUIRED RECORDS, THE IDENTIFICATION MARKS OF WELDERS, A LIST OF DEFECTIVE
WELDS, AND THE MANNER OF CORRECTING DEFECTS.
5. THE SPECIAL INSPECTOR SHALL FURNISH THE ARCHITECT, STRUCTURAL ENGINEER,
CONTRACTOR, AND THE LOCAL BUILDING AUTHORITY WITH A REPORT THAT ALL WELDING
IS IN CONFORMANCE WITH THE APPROVED STRUCTURAL DOCUMENTS AND HAS BEEN
DONE IN ACCORDANCE WITH AWS D1.1, STRUCTURAL WELDING CODES.
STEEL DECK
CONTRACTOR SHALL PERFORM THE FOLLOWING:
1. SUBMIT MILL CERTIFICATION THAT THE SUPPLIED STEEL COMPLIES WITH THE
SPECIFICATIONS.
2. SPECIAL INSPECTOR SHALL PERFORM PERIODIC INSPECTIONS OF THE FOLLOWING:
3. VERIFY GENERAL ALIGNMENT AND DECK LAP.
4. VERIFY WELDS FOR SIZE AND PATTERN.
5. VERIFY SPACING AND TYPE OF SIDELAP ATTACHMENTS.
6. VERIFY INSTALLATION DECK CLOSURES.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /S tr u c t
In te g ra te d
H e a lt h
.r v t
/2
/2
:1
:1
P
M
S1.00
STRUCTURAL NOTES TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
BFC05-20-2022
626-309
BFC
S T R U C T U R A L N O T E S Q U A L I T Y C O N T R O L
Revisions: Date:
J
I
H
G
F
B
A
10987
5.1 5.2
H1
F3
F2
E1
I2
H3
G1
12.511.5
9.57.5
F4
00 01 02 03
7.1
9.1
4.5
5.5
B.2
C.5
C.6
E.3
F.3
STAIRS
G09
KITCHENETTE
G08A
MUSIC THERAPY CLINIC
G13
MUSIC STORAGE
G13A
WORK
G12A
EDUC CHIEF
G17A
RECREATION
STORAGE
G08B
HAC
G07
KINESIO GROUP THERAPY
G12
WC STORAGE
G12B
MALE
G09A
FEMALE
G09C
REC. THERAPY CLINIC
G08
BARBER CART
G02
FOOD SERVICE CHIEF
G03FOOD SERVICE VEND SUPPLY
G04
CORRIDOR
G45
ENTRY
G01
CORRIDOR
G46
CONNECTOR
G47
COURTYARD
G10
WORK AREA
G15
CORRIDOR
G55
PRACTICE ROOM
G13B
PMRS CONSULT
G14
CHASE
G-104A
FEMALE SHOWER
G09D
MALE SHOWER
G09B
28'-3" 20'-8"
A R
E A
A
A R
E A
B
A R
E A
A
A R
E A
B
10.1 11.9 12.9
E.4
E.9
'-1
/8
8" REINFORCED CONC WALL WITH
CONC STRIP FOOTING BENEATH
EDGE OF NEW SLAB ON GRADE
8" REINFORCED CONC WALL WITH
CONC STRIP FOOTING BENEATH
EDGE OF NEW SLAB ON GRADE
SLAB INFILL AT RECESSED SLAB:
4" CONC. SLAB ON GRADE REINFORCED
WITH 6x6-W2.9xW2.9 W.W.F. OVER 15 MIL
VAPOR BARRIER AND COMPACTED
DRAINAGE FILL TO RAISE THE NEW SLAB
TO ALIGN WITH TYPICAL EXISTING FLOOR
ELEVATION.
DRILL AND EPOXY #4 x 24 DOWELS AT 16"
O.C. WITH 6" MIN. EMBED. INTO EXISTING
SLAB AT NEW/EXISTING SLAB INTERFACE
(PROVIDE 6" EMBED.)
H
SS
8X 8X
3/
H
SS
8X 8X
3/
H
SS
8X 8X
3/
H S S 8X8X3/8
H
SS
8X 8X
3/
H
SS
8X 8X
3/
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
SLAB ON GRADE NOTE:
4" CONC. SLAB ON GRADE
REINFORCED WITH 6x6-W2.9xW2.9
W.W.F. OVER 15 MIL VAPOR BARRIER
AND 4" COMPACTED DRAINAGE FILL.
(5
.0'
(5
.0'
(5
.0'
(5
.0'
(5
.0'
FIN. SLAB ELEV. = 589.5' +/- (MATCH EXIST.)
FIN. SLAB ELEV. = 589.5' +/- (MATCH EXIST. MAIN FLR)
" D
R
IL
LE
D
P
IE
R
(5
.0'
GB (32x30)
G B x3 0)
G B x3 0)
G B
(24x30)
GB (32x30) GB (18x24)
GB (32x30)
1' -0
1/
2"
1/
2"
1' -4
1'
-0
1' -0
8"
S4.01
S4.01
S4.01
S4.01
5"
5"
S4.02
6'-2" 9'-9" 4'-9"
9' -5
/8
9'
-5
2' -0
H S S6X6X3/8
H S S6X6X3/8
H S S6X6X3/8
GALV.
GALV.
GALV.
PROVIDE 24" DIA. x 5'-0"
DEEP PIER AT SCREEN
WALL (TYP.)
WIDEN GRADE BEAM AT END
SCREENWALL COLUMN TO
ENCOMPASS COLUMN
(2)-HSS6x6x1/4" BEAMS (GALV)
BETWEEN HSS POSTS (ONE
WITH BOTTOM AT 1'-0" ABOVE
GRADE AND ONE WITH TOP
AT 6'-0" ABOVE GRADE)
SLAB DEPRESSION,
COORD. W/ ARCH
(REF. 1/S4.03).
2'-0" MAX.
S4.02
S4.03
CORRIDOR
G46
ELEC.
G28
ELEC.
G29
R A
M P
D O
W N
R A
M P
D O
W N
S4.03
S4.03
S4.03
S4.03
S4.03
S4.04
S4.03
S4.03
S4.03
S4.01
S4.03
A
2'-0" MAX.
2'-0" MAX.
S4.04
PLAN NOTES:
1. DRILLED PIERS TO BE SOCKETED 2'-0" INTO SOUND ROCK
2. ELEVATION DENOTED BY (5xx.x') REPRESENTS ANTICIPATED ELEVATION OF
ROCK BASED ON PREVIOUS PROJECT BORINGS. BID LENGTHS SHALL BE BASED
ON ANTICIPATED ROCK ELEVATION PLUS THE 2'-0" SOCKET.
3. DRILLED PIER BEARING SURFACE TO BE EVALUATED BY GEOTECHNICAL
ENGINEER BY DRILLING AND PROBING A MINIMUM OF ONE PERCUSSION HOLE
(2" DIA. x 6' DEEP) AT EACH DRILLED PIER TO CONFIRM BEARING MEDIUM MEETS
OR EXCEEDS DESIGN PARAMETERS.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA A
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /S tr u c t
In te g ra te d
H e a lt h
.r v t
/2
/2
:1
:2
P
M
S1.01A
FOUNDATION PLAN - AREA "A" TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
Checker05-20-2022
626-309
Author
1/8" = 1'-0"
FOUNDATION PLAN - AREA "A"
CR
I
H
G
F
G1
17 18 19 22
F4
F1
E2
D1
C1
B1
H2
I1
I3
K
L
15.1 15.2 17.1 17.2
E.9
E.4
20 21
ELECTRICAL
G41
MEDIA COORD.
G17B
LOBBY
G36
MALE
G37
FEMALE
G38
VESTIBULE
G35
SECURITY
G35A
HAC
G30I
PAT. RESOURCE
G40
STORAGE
G34A
SIM MAINTENANCE
G30G
PROCEDURE SIM LAB
G30F
CONTROL ROOM
G30E
DE-BRIEF
G30A
TRNG EQUIP STOR
G30C
ALS CLASSROOM
G30J
MALE
G25
WAITING
G39
LACTATION
G27
MULTI-PURPOSE
G20J
MULTI-PURPOSE
G20F
MULTI-PURPOSE
G20D
MULTI-PURPOSE
G20B
MULTI-PURPOSE
G20
MULTI-PURPOSE
G20H
STOR.
G20A
STOR.
G20E
STOR
G20G
STOR.
G20I
STOR.
G20C
MED/SURG SIM LAB
G30D
VENDING
G32
STAFF LOUNGE
G33
KITCHEN/SERVING
G21
EDUC CHIEF
G17A
WORK
G17
WHOLE HEALTH STORAGE
G18
CORRIDOR
G30
STORAGE
G30K
RT SPVR.
G15A
COMPUTER LAB
G16
CREATIVE ARTS GROUP
G34
CORRIDOR
G48
CORRIDOR
G48A
CORRIDOR
G49
CORRIDOR
G50
CORRIDOR
G51
STORAGE
G20K
FEMALE
G24
MUSIC THER. 1
G43 MUSIC THER. 2
G42
CORRIDOR
G54
CORRIDOR
G52
STORAGE
G30H
ACCESS STAIR
G26
CHASE
G26A
PMRS STORAGE
G31
CHARGING CART STOR.
G19
CORRIDOR
G30
ENTRY
G44
CORRIDOR
G53
J.5
K.1
K.9
K.8
23 25 2624
17.5 18.916.5
C.6 C.6
20.2 21.5
B.2 B.2
E.5 E.5
F.3 F.3
48'-8 1/8" 21'-7 3/8" 25'-2 5/8" 25'-2 5/8" 21'-7 3/8"
IT
G23
A R
E A
A
A R
E A
B
A R
E A
A
A R
E A
B
12.9
E.4
E.9
4' -1
3/
'-1
3/
4' -9
'-9
/4
5' -7
/2
'-2
/1 6"
1' -8
H S S10X10X3/8
H S S10X10X3/8
H S S10X10X3/8
H S
S
X10 X3/
H S
S
X10 X3/
H S
S
X10 X3/
H S S10X10X3/8
H S S10X10X3/8
W
X60
W
X60
W
X60
W
X60
W
X60
W
X60
W
X60
H
SS
8X 8X
3/
H
SS
8X 8X
3/
H
SS
8X 8X
3/ 8H S S8X8X3/8
H
SS
8X 8X
3/
H
SS
8X 8X
3/
H S
S 8X
8X 3/
H S S8X8X3/8
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
24" D R
ILLED
PIER
24" D R
ILLED
PIER
24" D R
ILLED
PIER
24" D R
ILLED
PIER
24" D R
ILLED
PIER
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
24" D R
ILLED
P
IE
R
24" D R
ILLED
P
IE
R
24" D R
ILLED
P
IE
R
" D
R
IL
LE
D
P
IE
R
24" D R
ILLED
P
IE
R
" D
R
IL
LE
D
P
IE
R
24" D R
ILLED
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
H S
S 5X
5X 3/
" D
R
IL
LE
D
P
IE
R
H
SS
5X 5X
3/
H S
S 5X
5X 3/
" D
R
IL
LE
D
P
IE
R
H
SS
5X 5X
3/
H S
S 5X
5X 3/
" D
R
IL
LE
D
P
IE
R
H
SS
5X 5X
3/
" D
R
IL
LE
D
P
IE
R
H S S6X6X3/8
H S S 6X6X3/8
" D
R
IL
LE
D
P
IE
R
H S S 6X6X3/8
H S S6X6X3/8
2'-0" THICK REINFORCED
CONCRETE PILE CAP
(PC2)
2'-0" THICK REINFORCED
CONCRETE PILE CAP
(PC2)
(5
.0'
(5
.0'
(576.0')
(573.0')
(571.0')
(5
.0'
(579.0')
(5
.0'
(570.0')
(5
.0'
(5
.0'
(5
.0'
(5
.0'
(5
.0'
(5
.0'
(5
.0'
(5
.0'
(5
.0'
(5
.0'
(5
.0'
(5
.0'
(5
.0'
SLAB ON GRADE NOTE:
4" CONC. SLAB ON GRADE
REINFORCED WITH 6x6-W2.9xW2.9
W.W.F. OVER 15 MIL VAPOR BARRIER
AND 4" COMPACTED DRAINAGE FILL.
FIN. SLAB ELEV. = 589.5' +/- (MATCH EXIST.)
SLAB ON GRADE NOTE REPAIR WHERE
REMOVED FOR NEW FOUNDATIONS:
4" CONC. SLAB ON GRADE REINFORCED WITH
6x6-W2.9xW2.9 W.W.F. OVER 15 MIL VAPOR
BARRIER AND 4" COMPACTED DRAINAGE FILL.
DRILL AND EPOXY #4 x 24 DOWELS AT 16" O.C.
WITH 6" MIN. EMBED. INTO EXISTING SLAB AT
NEW/EXISTING SLAB INTERFACE
(PROVIDE 6" EMBED.)
FIN. SLAB ELEV. = 589.5' +/- (MATCH EXIST.)
SLAB INFILL AT RECESSED SLAB:
4" CONC. SLAB ON GRADE REINFORCED WITH
6x6-W2.9xW2.9 W.W.F. OVER 15 MIL VAPOR
BARRIER AND 4" COMPACTED DRAINAGE FILL.
DRILL AND EPOXY #4 x 24 DOWELS AT 16" O.C.
WITH 6" MIN. EMBED. INTO EXISTING SLAB AT
NEW/EXISTING SLAB INTERFACE
(PROVIDE 6" EMBED.)
FIN. SLAB ELEV. = 589.5' +/- (MATCH EXIST.)
POOL INFILL SLAB ON GRADE:
4" CONC. SLAB ON GRADE REINFORCED
WITH 6x6-W2.9xW2.9 W.W.F. OVER 15 MIL
VAPOR BARRIER AND COMPACTED
DRAINAGE FILL TO RAISE THE NEW SLAB
TO ALIGN WITH TYPICAL EXISTING FLOOR
ELEVATION.
DRILL AND EPOXY #4 x 14" LONG DOWELS
AT 16" O.C. WITH 6" MIN. EMBED. INTO
EXISTING SLAB AT NEW/EXISTING SLAB
INTERFACE (PROVIDE 6" EMBED.)
FIN. SLAB ELEV. = 589.5' +/- (MATCH EXIST. MAIN FLR)
FLOOR FILL USED ON EXISTING
POOL DECK SHALL NOT
EXCEED 30 PSF
(BASIS OF DESIGN IS 4-1/2" OF
ARDEX LW FLOOR TOPPING)
C.5 C.5
E.3 E.3
17.4 18.8 20.1
16.6 21.3
2'-6"
3'-2"
2'-6"
4'-9" 4'-9" 4'-9"
2'-6" 3'-2"
2'-6"
G B
(24x30)
GB (18x24)
GB (32x30)
G B x3 0)
G B x3 0)
G B x3 0)
G B x3 0)
G B x3 0)
GB (24x30)
GB (24x30)
G B x3 0)
G B x3 0)
G B x3 0)
GB (24x30) GB (24x30)GB (24x30)
GB (24x30)GB (24x30) GB (24x30)
GB (32x30)
G B x3 0)
GB (32x30)
GB (32x30)
G B x3 0)
G B x3 0)
TOP OF GRADE
BEAM 1'-0" BFF
S4.01
S4.02
S4.01
S4.02
9' -9
2' -6
4'
-9
2' -6
2' -6
4'
-9
2' -6
9' -9
S4.02
S4.02
2'-0" THICK REINFORCED
CONCRETE PILE CAP
(PC2)
2'-0" THICK REINFORCED
CONCRETE PILE CAP
(PC2)
2'-0" THICK REINFORCED
CONCRETE PILE CAP
(PC2)
S4.02
S4.02
S4.02
S4.02
S4.02
1' -0
1'
-0
/2
1/
2"
1/
2" 1'
-0
/2
1' -4
1'-4" 1'-0 1/2"
3 1/2"
1'-0"
1'-0 1/2"
7 1/2"
1' -0
1' -0
/2
1/ 2"
S4.01
3 1/2" 1'-0 1/2"
1'-4"
S4.02
S4.02
(574.0')
(572.0')
(570.0')
(578.0')
(576.0')
4'-9"
H S S6X6X3/8
GALV.
PROVIDE 2"Hx6"W CURB
AT SLAB EDGE FOR
CURTAINWALL, REF/. 6/S4.02
8'-2"8'-2"
4'-6"
4' -3
4' -3
4'-6"4'-6"
4' -3
ELEC.
G28
ELEC.
G29
R A
M P
D O
W N
REFERENCE 2/S1.01B
FOR CONTINUATION
COMM/MEDIA CONTROL
G22
S4.03
S4.03
S4.03
S4.03
S4.03
S4.03
EXTERIOR ON GRADE NOTE:
4" CONC. SLAB ON GRADE
REINFORCED WITH 6x6-W2.9xW2.9
W.W.F. OVER 15 MIL VAPOR BARRIER
AND 4" COMPACTED DRAINAGE FILL.
(SLOPE AWAY FROM BLDG - REF. CIVIL)
S4.03
S4.03
2'-0" MAX.
S4.04
DRILL AND EPOXY #4x2'-0" LONG BARS AT 12" O.C.
INTO EXISTING EDGE OF SLAB AT EXIST.
INTERFACE (PROVIDE 6" MIN. EMBED.)
6"
1'-6" MAX.
3' -8
/8
9'
-6
/1 6"
7' -0
/2
7'-0" 6'-6 5/8"
2'-4 3/8"
S4.04
18'-7 1/2" 18'-9" 18'-9" 18'-9" 18'-9" 18'-9 1/2"
PLAN NOTES:
1. DRILLED PIERS TO BE SOCKETED 2'-0" INTO SOUND ROCK
2. ELEVATION DENOTED BY (5xx.x') REPRESENTS ANTICIPATED ELEVATION OF
ROCK BASED ON PREVIOUS PROJECT BORINGS. BID LENGTHS SHALL BE BASED
ON ANTICIPATED ROCK ELEVATION PLUS THE 2'-0" SOCKET.
3. DRILLED PIER BEARING SURFACE TO BE EVALUATED BY GEOTECHNICAL
ENGINEER BY DRILLING AND PROBING A MINIMUM OF ONE PERCUSSION HOLE
(2" DIA. x 6' DEEP) AT EACH DRILLED PIER TO CONFIRM BEARING MEDIUM MEETS
OR EXCEEDS DESIGN PARAMETERS.
VESTIBULE
G35
SECURITY
G35A
STORAGE
G34A
CREATIVE ARTS GROUP
G34
CORRIDOR
G53
J.5
K.1
K.9
K.8
23 25 2624
H
SS
8X 8X
3/ 8H S S8X8X3/8
H
SS
8X 8X
3/
H
SS
8X 8X
3/
H S
S 8X
8X 3/
H S S8X8X3/8
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
" D
R
IL
LE
D
P
IE
R
(5
.0'
(5
.0'
(5
.0'
(5
.0'
(5
.0'
SLAB ON GRADE NOTE:
4" CONC. SLAB ON GRADE
REINFORCED WITH 6x6-W2.9xW2.9
W.W.F. OVER 15 MIL VAPOR BARRIER
AND 4" COMPACTED DRAINAGE FILL.
FIN. SLAB ELEV. = 589.5' +/- (MATCH EXIST.)
GB (32x30)
G B x3 0)
GB (32x30)
GB (32x30)
G B x3 0)
G B x3 0)
S4.02
S4.02
1' -0
1'
-0
/2
1/
2"
1/
2" 1'
-0
/2
1' -4
1'-4" 1'-0 1/2"
3 1/2"
1'-0"
1'-0 1/2"
7 1/2"
1' -0
1' -0
/2
1/ 2"
S4.01
3 1/2" 1'-0 1/2"
1'-4"
S4.02
S4.02
PROVIDE 2"Hx6"W CURB
AT SLAB EDGE FOR
CURTAINWALL, REF/. 6/S4.02
RAMP DOWN
RAMP DOWN
S4.03 10
S4.03
S4.03
SIM.
EXTERIOR ON GRADE NOTE:
4" CONC. SLAB ON GRADE
REINFORCED WITH 6x6-W2.9xW2.9
W.W.F. OVER 15 MIL VAPOR BARRIER
AND 4" COMPACTED DRAINAGE FILL.
(SLOPE AWAY FROM BLDG - REF. CIVIL)
S4.03
S4.03
S4.03
S4.04
S4.03
B
DRILL AND EPOXY #4x2'-0" LONG BARS AT 12" O.C.
INTO EXISTING EDGE OF SLAB AT EXIST.
INTERFACE (PROVIDE 6" MIN. EMBED.)
6"
1'-6" MAX.
3' -8
/8
9'
-6
/1 6"
7' -0
/2
7'-0" 6'-6 5/8"
2'-4 3/8"
S4.03
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA B
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /S tr u c t
In te g ra te d
H e a lt h
.r v t
/2
/2
:1
:4
P
M
S1.01B
FOUNDATION PLAN - AREA "B" TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
Checker05-20-2022
626-309
Author
1/8" = 1'-0"
FOUNDATION PLAN - AREA "A"
1/8" = 1'-0"
FOUNDATION PLAN - AREA "A"
H
G
F
D
C
B
A
10987
5.1 5.2
H1
F3
F2
E1
I2
H3
G1
12.511.5
9.57.5
F4
D1
C1
B1
00 01 02 03
7.1
9.1
4.5
5.5
B.2
C.5
C.6
E.3
F.3F.3
W18X40
W18X40
W16X26
W16X26
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
W
X
ROOF DECK NOTE:
22 GA. 1-1/2" DEEP, TYPE "B" ROOF DECK
(GALVANIZED) WITH STEEL SUPPORTS
EQUALLY SPACED AS SHOWN WITH
6'-0" MAXIMUM SPACING
TOP OF STEEL ELEV. = 11'-5 1/2" A.F.F.
A R
E A
A
A R
E A
B
A R
E A
A
A R
E A
B
10.1 11.9 12.9
E.4
E.9
28'-3" 20'-8"
'-1
/8
PRE-ENGINEERED
SUSPENDED CANOPY
PRE-ENGINEERED
SUSPENDED CANOPY
PRE-ENGINEERED
SUSPENDED CANOPY
S4.51
S4.51
S4.51
S4.51
1/
2" 3"
VERIFY
FIELD
VERIFY
FIELD 1" EXP. JT.
S4.52
S4.52
S4.52
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA A
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /S tr u c t
In te g ra te d
H e a lt h
.r v t
/2
/2
:1
:5
P
M
S1.02A
LOW ROOF FRAMING PLAN - AREA
"A"
TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
Checker05-20-2022
626-309
Author
1/8" = 1'-0"
LOW ROOF FRAMING PLAN - AREA "A"
H
G
F
G1
17 18 19 22
F4
F1
E2
D1
C1
B1
H2
I1
I3
K
L
15.1 15.2 17.1 17.2
12.9
20 21
J.5
K.1
K.9
K.8
23 25 2624
17.5 18.916.5
C.6
20.2 21.5
B.2
E.5
F.3
30k
W18X40 (12)
30k 30k
W18X50 (12)
30k 30k
W18X50 (12)
30k 30k
W18X40 (12)
30k k
W
4X
(1
2) k k
W k k
W k k
W k k
W k k
W k k
W k k
W k k
W k k
W k k
W k k
W k k
W k k
W k k
W k k
W k k
W k
30k
W18X40 (12)
30k 30k
W24X55 (12)
30k 30k
W24X55 (12)
30k 30k
W18X40 (12)
30k
3' -8
/8
9'
-6
/1 6"
7' -0
/2
W
X
W
X
W12X14
W
X
W12X14
W12X14
W
X
W12X14
W12X14
W12X14
W16X26
W16X26
W
X
W
X
ROOF DECK NOTE:
22 GA. 1-1/2" DEEP, TYPE "B" ROOF DECK
(GALVANIZED) WITH STEEL SUPPORTS
EQUALLY SPACED AS SHOWN WITH
6'-0" MAXIMUM SPACING
TOP OF STEEL ELEV. = 11'-4 1/2" A.F.F.
A R
E A
A
A R
E A
B
A R
E A
A
A R
E A
B
12.9
E.4
E.9
48'-8 1/8" 21'-7 3/8" 25'-2 5/8" 25'-2 5/8" 21'-7 3/8"
4' -1
3/
C.5
E.3
17.4 18.8 20.1
16.6 21.3
SLAB ON METAL DECK:
3-1/4" SEMI-LT WT. CONC (110 PCF) OVER 2" COMPOSITE
FLOOR DECK (22 GA.-GALV.). REINFORCE SLAB WITH 6x6- W2.9xW2.9 WWF (TOTAL THICKNESS 5-1/4")
STEEL BEAMS EQUALLY SPACED AS SHOWN WITH 7'-0"
MAX. SPACING.
FIN. SLAB ELEV. = 13'-2 1/4" A.F.F.
3'-2"
4'-9" 4'-9" 4'-9"
3'-2"
'-1
3/
4' -9
'-9
/4
5' -7
/2
'-2
/1 6"
W / E
X
IS
T W
A
LL
1' -4
(V
E R
IF
Y
5"
5"
5"
PRE-ENGINEERED
SUSPENDED CANOPY
PRE-ENGINEERED
SUSPENDED CANOPY
S4.51
6"
6"
6"
6"
6"
6"
6"
VERIFY
FIELD
S4.51
VERIFY
FIELD 1" EXP. JT.
PRE-ENGINEERED
SUSPENDED CANOPY
S4.52
S4.52
S4.51
S4.51
S4.51
S4.52
S4.51
SIM.
7'-0" 6'-6 5/8"
2'-4 3/8"
18'-7 1/2" 18'-9" 18'-9" 18'-9" 18'-9" 18'-9 1/2"
S4.52
FLOOR PLAN NOTES:
DENOTES WELDED MOMENT CONNECTION
(REF. DETAILS 11 & 12 /S.51)
COMPOSITE FLOOR SLAB AND FRAMING NOTES:
[24] DENOTES REQUIRED NUMBER OF SHEAR CONNECTORS FOR BEAM OR
GIRDER. WHEN MORE THAN ONE SUCH NUMBER IS SHOWN FOR A GIRDER,
EACH NUMBER DENOTES THE REQUIRED NUMBER OF SHEAR
CONNECTORS BETWEEN CONCENTRATED LOAD POINTS. WHEN NUMBER
OF SHEAR CONNECTORS IS NOT SHOWN, COMPOSITE FLOOR BEAMS
SHALL RECEIVE SHEAR CONNECTORS AT 12" O.C.
15k DENOTES BEAM OR GIRDER END REACTION (SERVICE LOADS)
FOR CONNECTION DESIGN. MINIMUM CONNECTION CONSIST OF
TWO ROWS OF BOLTS. WHERE NO VALUE IS SHOWN ON COMPOSITE
BEAMS, REACTION IS LESS THAN OR EQUAL TO 10 K.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA B
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /S tr u c t
In te g ra te d
H e a lt h
.r v t
/2
/2
:1
:0
P
M
S1.02B
SECOND FLOOR / LOW ROOF
FRAMING PLAN - AREA "B"
TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
Checker05-20-2022
626-309
Author
1/8" = 1'-0"
2ND FLOOR/LOW ROOF FRAMING PLAN - AREA "B"
H
G
F
G1
17 18 19 22
F4
F1
E2
D1
C1
B1
H2
I1
I3
K
L
15.1 15.2 17.1 17.2
20 21
J.5
K.1
K.9
K.8
23 252624
17.5 18.916.5
C.6
20.2 21.5
B.2
E.5
W
X
W
X
W
X
W18X50 (w/ C10X15.3 ON BOTT FLANGE)W18X50 (w/ C10X15.3 ON BOTT FLANGE)
F.3
A R
E A
A
A R
E A
B
A R
E A
A
A R
E A
B
12.9
E.4
E.9
48'-8 1/8" 21'-7 3/8" 25'-2 5/8" 25'-2 5/8" 21'-7 3/8"
4' -1
3/
'-1
3/
4' -9
'-9
/4
5' -7
/2
'-2
/1 6"
(BOTT. OF STL = 16'-0" A.F.F.) (BOTT. OF STL = 16'-0" A.F.F.)
(B O
T T
. O F
S T
L
6'
-0
A .F
.F
(B O
T T
. O F
S T
L
6'
-0
A .F
.F
(B O
T T
. O F
S T
L
6'
-0
A .F
.F
W
X
W12X26
W12X26
W
X
W12X26
W12X26
W
X
W12X26
W12X26
W12X14
W
X
W12X14
W
X
E X
IS
T
IN
G
R O
O F
T R
U S
S
E X
IS
T
IN
G
R O
O F
T R
U S
S
E X
IS
T
IN
G
R O
O F
T R
U S
S
E X
IS
T
IN
G
R O
O F
T R
U S
S
E X
IS
T
IN
G
R O
O F
T R
U S
S
DASHED LINES REPRESENT L4x4x5/16"
KICKERS AT 6'-0" O.C. MAX. EACH SIDE OF
BEAMS UP TO TOP CHORD OF EXISTING
TRUSS OR JOIST AT ROOF (TYP.)
DASHED LINES REPRESENT L4x4x5/16"
KICKERS AT 6'-0" O.C. MAX. EACH SIDE OF
BEAMS UP TO TOP CHORD OF EXISTING
TRUSS OR JOIST AT ROOF (TYP.)
C.5
E.3
17.4 18.8 20.1
16.6 21.3
3'-2"
4'-9" 4'-9" 4'-9"
3'-2"
18'-7 1/2" 18'-9" 18'-9" 18'-9" 18'-9" 18'-9 1/2"
W
X
W
X
W
X
W12x40
S4.52
S4.52
Sim
S4.52
Sim
W12x40W12x40
S4.52
S4.52
Sim
OPP.
HAND
W12x40W12x40
S4.52
S4.52
SIM.
S4.52
SIM.
EXISTING JOISTS, TYP.
EXISTING JOISTS, TYP.
REF. 11/S4.52 FOR
ATTACHMENT AT ROOF
REF. 11/S4.52 FOR
ATTACHMENT AT ROOF
REF. 11/S4.52 FOR
ATTACHMENT AT ROOF
W16X40 (TOP OF STEEL ELEV. = 19'-0")W16X40 (TOP OF STEEL ELEV. = 19'-0")
EXISTING JOISTS, TYP.
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA B
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /S tr u c t
In te g ra te d
H e a lt h
.r v t
/2
/2
:1
:1
P
M
S1.03B
ROOF FRAMING PLAN - AREA "B" TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
Checker05-20-2022
626-309
Author
1/8" = 1'-0"
ROOF FRAMING PLAN - AREA "B"
CONTRACTOR: COORINDATE ANTICIAPTED MEANS OF
DELIVERING 50'+ LONG BEAMS INSIDE EXISTING GYMNASIUM.
INCLUDE ALL REQUIRED COSTS ASSOCIATED WITH PLANNED
DELIVERY INSIDE BUILDING.
TYP. FORMED CONSTRUCTION JOINT
TYP. SAWN CONTROL JOINT
SMOOTH DOWEL SCHEDULE
M
IN
P
L A
N
S E
E
"D
"D
P L A
N
S E
E
1'-4" 1'-4"
SMOOTH DOWELS
REF. SCHEDULE
SLAB REINFORCING
NOT CONTINUOUS
SLAB REINFORCING
CONTINUOUS
EDGES SMOOTH & STRAIGHT
PRIOR TO SEALING
CONTRACTOR TO GRIND
FILL JOINT WITH SEALANT.
FILL JOINT WITH SEALANT.
CONTRACTOR TO GRIND
EDGES SMOOTH & STRAIGHT
PRIOR TO SEALING
1/8" to 1/4" (BLADE THICKNESS)
SLAB DEPTH
(INCHES)
4 TO 6
7 TO 8
9 TO 11
DOWEL DIAMETER
(INCHES)
3/4
1 1/4
TOTAL DOWEL LENGTH
(INCHES)
DOWEL SPACING
ON CENTERS (IN.)
(4)-#5 BARSxCONT.
PLACE DOWELS AT MID-DEPTH OF THICKENED PORTION OF SLAB AND
HOLD IN PLACE WITH DOWEL BASKETS
NOTE: CONTROL JOINTS SHALL BE SPACED AT INTERVALS NOT TO EXCEED 12'-0" O.C.
EACH DIRECTION, WITH ENCLOSED AREA NOT TO EXCEED 144 SF. WHERE APPLICABLE ,
JOINTS SHOULD BE LOCATED ON COLUMN CENTERLINES AND AT SLAB RE-ENTRANT
CORNERS. LENGTH TO WIDTH PROPORTIONS OF JOINT PATTERN SHALL NOT EXCEED
1.35:1. (TYPICAL FOR ALL CONCRETE SLABS ON GRADE UNLESS NOTED OTHERWISE ON
PLANS).
CONTRACTOR SHALL SUBMIT A SHOP DRAWING OF ANTICIPATED CONTROL JOINT
LOCATIONS FOR RECORD.
COORDINATE LOCATIONS OF CONST./CONTROL JOINTS WITH
ARCHITECTURAL FINISH SUCH AS TILE FLOORING.
COLUMN
1/2" FIBER JOINT
MATERIAL (TYP.)
EXTERIOR FINISH
CONSTRUCTION JOINT
OR CONTROL JOINT
INTERIOREXTERIOR
2" DIAMETER TEST HOLE
6' -0
M
IN
R
E F
. S C
H E
D U
LE
R O
C K
E M
B E
D M
E N
T D
R
IL
LE
D
P
IE
R R
E F
. S C
H E
D
R E
F . S
E C
T
IO
N S
DRILLED PIER, REF. PLAN AND
SCHEDULE FOR SIZE, LOCATION,
AND REINFORCING
COMPETENT ROCK
FINSHED SLAB
TOP OF GRADE BEAM
TOP OF DRILLED PIER
TOP OF ROCK
BID ELEVATION = REF. PLAN
GRADE BEAM,
REF. SCHEDULE
DRILLED PIER SCHEDULE
MARK DIAMETER REINFORCING
MINIMUM ROCK
EMBEDMENT
24DP-2 24" (10)-#7 VERTICAL BARS AND #3 TIES AT 12" O.C. 2'-0"
GRADE BEAM SCHEDULE
MARK SIZE (WxH) REINFORCING
GB-24x30 24"x30" (6)-#8xCONT. BARS TOP AND BOTTOM WITH #4 TIES AT 12" O.C.*
EXTEND DRILLED PIER
REINFORCING INTO GRADE
BEAM WITH STANDARD
HOOKS AT TOP
GB-32x30 32"x30" (7)-#8xCONT. BARS TOP AND BOTTOM WITH #4 TIES AT 12" O.C.*
COMMENTS
COMMENTS
GB-18x24 18"x24" (4)-#7xCONT. BARS TOP AND BOTTOM WITH #4 TIES AT 12" O.C.
* PROVIDE TIES AT 6" O.C. FROM CENTER OF
PIER TO END OF CANTILEVERS
* PROVIDE TIES AT 6" O.C. FROM CENTER OF
PIER TO END OF CANTILEVERS
GB-24x24 24"x24" (5)-#8xCONT. BARS TOP AND BOTTOM WITH #4 TIES AT 12" O.C.
PILE CAP SCHEDULE
MARK WIDTH REINFORCING
PC2 REF. PLAN #7 BARS AT 10" O.C. EACH WAY, TOP AND BOTTOM
COMMENTS
SIZE
HEIGHT LENGTH
2'-0" REF. PLAN PROVIDE HOOKS ON
EACH END (TYP.)
CENTERLINE COL. AND PIER
ISOLATION JOINT
(1/2" JOINT FILLER)
REF. SCHEDULE FOR
BASE PLATE AND
ANCHOR BOLTS
NON-SHRINK
GROUT
R E
F . S
C H
E D
U
LE
1' -4
DRILLED PIER, REF. PLAN AND
SCHEDULE FOR SIZE, LOCATION,
AND REINFORCING
TOP OF GRADE BEAM
TOP OF DRILLED PIER
GRADE BEAM,
REF. SCHEDULE
STEEL COLUMN
REF. PLAN
GRADE BEAM,
REF. SCHEDULE
SLAB OUTLINE BEYOND
COMPACTED
DRAINAGE FILL
STD. HOOK AT
ENDS, TYPICAL
GROUT CAVITY SOILD
BELOW GRADE
APPROX. FIN. GRADE OR
EXTERIOR CONC., REF. CIVIL
REF. PLN
REF. PLN REF. PLN
CENTERLINE COL.
AND PIER BEYOND
R E
F . S
C H
E D
U
LE
1' -4
DRILLED PIER BEYOND,
REF PLAN
TOP OF GRADE BEAM
TOP OF DRILLED PIER
GRADE BEAM,
REF. SCHEDULE
GRADE BEAM,
REF. SCHEDULE
COMPACTED
DRAINAGE FILL
GROUT CAVITY SOILD
BELOW GRADE
APPROX. FIN. GRADE OR
EXTERIOR CONC., REF. CIVIL
REF. PLN
REF. PLN REF. PLN
CENTERLINE COL.
AND PIER BEYOND
R E
F . S
C H
E D
U
LE
1' -4
DRILLED PIER BEYOND,
REF PLAN
TOP OF GRADE BEAM
TOP OF DRILLED PIER
GRADE BEAM,
REF. SCHEDULE
GRADE BEAM,
REF. SCHEDULE
COMPACTED
DRAINAGE FILL
REF. PLN REF. PLN
FACE OF STUD WALL BEYOND
BRICK VENEER BEYOND
EXTERIOR DOORWAY, REF. ARCH.
1/2" JOINT MATERIAL (TYP.)
SLAB EDGE BEYOND
DOORWAY
AT DOORWAY
EXTEND SLAB 5"
4" CONC. SLAB OVER 4" MIN. COMPACTED
DRAINAGE FILL. REINFORCE SLAB WITH
6x6-2.9xW2.9 WWF (SLOPE AWAY FROM
BLDG, REF. CIVIL)
TURN DOWN EXTERIOR SLAB
TO TOP OF GRADE BEAM AT
DOORWAY (TYP.)
DRILL AND EPOXY #4 DOWELSx24" LONG AT 10" O.C.
INTO BLDG SLAB EDGE (PROVIDE 6" EMBED.)
DOWEL SCHEDULE
"D
V E
R
IF
Y
F
IE
L D
WIDTH AS REQUIRED
(SAWCUT EXISITNG SLAB)
SLAB DEPTH
(INCHES)
4 TO 6
7 TO 8
9 TO 11
DOWEL DIA
(INCHES)
1/2
3/4
DOWEL LENGTH
(INCHES)
DOWEL SPACING
C/C (IN.)
EMBEDMENT
(INCHES)
NOTES:
1) COORDINATE LOCATIONS OF REQUIRED TRENCHING FOR UTILITIES WITH
MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS
2) DOWELS TO BE INSTALLED AT MID-DEPTH OF EXISTING SLAB ON GROUND
3) DOWELS TO BE INSTALLED IN EXISTING SLAB USING HILTI "HIT HY 150"
SYSTEM (FOLLOW MFG RECOMMENDED PROCEDURES)
4) NEW CONCRETE TO BE 3,500 PSI WITH MAXIMUM SLUMP BETWEEN 4"
AND 6".
5) FILL EXCAVATION WITH HAND COMPACTED #67 GRANULAR FILL AS
REQUIRED PRIOR TO INSTALLED SLAB INFILL
6) INSTALL NEW 10-MIL VAPOR BARRIER BENEATH SLAB (LAPPED WITH
EXISTING)
EDGE OF
TRENCH
EXCAVATION
COMPACTED GRANULAR
FILL
EXISTING CONCRETE
SLAB ON GROUNDDOWELS PER
SCHEDULE BELOW
#3 AT 12" O.C.
EACH WAY
CENTERLINE COL. AND PIER
ISOLATION JOINT
(1/2" JOINT FILLER)
REF. SCHEDULE FOR
BASE PLATE AND
ANCHOR BOLTS
NON-SHRINK
GROUT
R E
F . S
C H
E D
U
LE
1' -4
DRILLED PIER, REF. PLAN AND
SCHEDULE FOR SIZE, LOCATION,
AND REINFORCING
TOP OF GRADE BEAM
TOP OF DRILLED PIER
GRADE BEAM,
REF. SCHEDULE
STEEL COLUMN
REF. PLAN
GRADE BEAM,
REF. SCHEDULE
COMPACTED
DRAINAGE FILL
STD. HOOK AT
ENDS, TYPICAL
EQUAL EQUAL
SAW CUT EXISTING SLAB AS REQUIRED TO
FACILITATE INSTALLATION OF NEW
FOUNDATIONS. DRILL AND EPOXY #4x24"
LONG DOWELS AT 16" O.C. AT NEW SLAB
TIE-IN. (PROVIDE 6" 'EMBED.)
EXISTING SLAB
HSS COLUMN BASE PLATE
COLUMN BASE PLATE AND ANCHOR BOLT SCHEDULE
BASE PLATE
WF COLUMN BASE PLATE
COLUMN BASE PLATE ELEVATION
ANCHOR BOLTS
PLAN VIEW PLAN VIEW
"D
"B
"C""C"
"A"
"D
"B
"D
"A"
"C""C" L E
N G
T H
"D
P R
O J
STEEL COLUMN,
REF. FOUNDATION PLAN BASE PLATE,
REF. SCHEDULE
TYP.
1/16" LESS THAN
COL'N THICKNESS
COLUMN
("A" x "B" x THICKNESS)
BASE PLATE SIZE
"C"
**NOTE: USE 2 1/2" GROUT AT ANCHOR BOLTS > 1" DIA.
USE 3" GROUT AT ANCHOR BOLTS > 1 1/2" DIA
STEEL COLUMN,
SEE FOUNDATION PLAN
TYP.
E M
B E
D
ANCHOR BOLTS,
REF. SCHEDULE
HEADED ANCHOR
BOLTS
C O
N C
GRADE/YIELD"D" DIAMETER EMBEDMENT
BASE PLATE
LEVELING NUT
STEEL COL.
SEE FOUNDATION PLAN
N O
N -S
H R
IN
K
G R
O U
T
M
IL
L
T H
IC
K
N E
S S
75% OF FLANGE
AND WEB THICKNESS
AT WF COLUMN
BASE PLATE,
REF. SCHEDULE
ANCHOR BOLTS,
REF. SCHEDULE
HSS5x5 13" x 13" x 1" 4 1/2" 4 1/2" 36 1" 12"
HSS8x8 17" x 17" x 1 1/2" 6" 6" 36 1-1/4" 16"
HSS10x10 19" x 19" x 1 1/4" 7" 7" 36 1-1/4" 16"
HSS6x6 14" x 14" x 1 1/4" 5" 5" 36 1" 16"
W10x49 19" x 19" x 1 1/2" 7" 7" 36 1-1/2" 21"
BOLT HOLE SIZE AND PLATE WASHER THICKNESS
BOLT DIA. HOLE OVERSIZE (MAX.) PLATE WASHER (MIN.) THICKNESS
3/4" TO 1" 5/16" OVERSIZED HOLE 1/4"
1" TO 2" 1/2" OVERSIZED HOLE 1/2"
OVER 2" 1" OVERSIZED HOLE 3/4"
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENT
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /S tr u c t
In te g ra te d
H e a lt h
.r v t
/2
/2
:1
:1
P
M
S4.01
SECTIONS AND DETAILS TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
Checker05-20-2022
626-309
Author
3/4" = 1'-0"
TYP. SLAB CONSTRUCTION/CONTROL JOINT DETAIL
3/4" = 1'-0"
TYP. COLUMN ISOLATION JOINTS
3/4" = 1'-0"
DRILLED PIER DETAIL/FOUNDATION SCHEDULE
3/4" = 1'-0"
EXTERIOR COLUMN DETAIL
3/4" = 1'-0"
EXTERIOR GRADE BEAM
3/4" = 1'-0"
EXTERIOR TURNDOWN AT STUD DOORWAY
3/4" = 1'-0"
TYP. EXIST. SLAB REPAIR FOR TRENCHING
3/4" = 1'-0"
INTERIOR COLUMN DETAIL
3/4" = 1'-0"
BASE PLATE SCHEDULE/DETAILS
CENTERLINE COL. AND
PIER BEYOND
R E
F . S
C H
E D
U
LE
1' -4
DRILLED PIER BEYOND,
REF. PLAN
TOP OF GRADE BEAM
TOP OF DRILLED PIER
GRADE BEAM,
REF. SCHEDULE
EQUAL EQUAL
SAW CUT EXISTING SLAB AS REQUIRED TO
FACILITATE INSTALLATION OF NEW
FOUNDATIONS. DRILL AND EPOXY #4x24"
LONG DOWELS AT 16" O.C. AT NEW SLAB
TIE-IN. (PROVIDE 6" 'EMBED.)
EXIST. CONC. SLAB
CENTERLINE COL.
REF. SCHEDULE FOR
BASE PLATE AND
ANCHOR BOLTS
NON-SHRINK
GROUT
R E
F . S
C H
E D
U
LE
1' -4
DRILLED PIER, REF. PLAN FOR
PIER LOCATIONS AND SCHEDULE
FOR SIZE AND REINFORCING
TOP OF GRADE BEAM
TOP OF DRILLED PIER
STEEL COLUMN
REF. PLAN
STD. HOOK AT
ENDS, TYPICAL
SAW CUT EXISTING SLAB AS REQUIRED TO
FACILITATE INSTALLATION OF NEW
FOUNDATIONS. DRILL AND EPOXY #4x24"
LONG DOWELS AT 16" O.C. AT NEW SLAB
TIE-IN. (PROVIDE 6" 'EMBED.)
EXISTING SLAB EXISTING SLAB
PILE CAP, REF. PLAN FOR DIMENSIONS
AND SCHEDULE FOR REINFORCING
CENTERLINE COL.
REF. SCHEDULE FOR
BASE PLATE AND
ANCHOR BOLTS
NON-SHRINK
GROUT
R E
F . S
C H
E D
U
LE
W / E
X
IS
T
C O
O R
D
DRILLED PIER, REF. PLAN FOR
PIER LOCATIONS AND SCHEDULE
FOR SIZE AND REINFORCING
TOP OF GRADE BEAM
TOP OF DRILLED PIER
SAW CUT EXISTING SLAB AS REQUIRED TO
FACILITATE INSTALLATION OF NEW
FOUNDATIONS. DRILL AND EPOXY #4x24"
LONG DOWELS AT 16" O.C. AT NEW SLAB
TIE-IN. (PROVIDE 6" 'EMBED.)
EXISTING SLAB
STD. HOOK AT
ENDS, TYPICAL
ROOM FOR DRILL HEAD
10" MAX TO ALLOW
EXISTING GRADE BEAM
EXISTING EXTERIOR VENEER
EXISTING EXTERIOR WALL
DRILL AND EPOXY #6 BARSx2'-6" LONG AT 10"
O.C. TOP AND BOTTOM (PROVIDE 6" EMBED.
INTO EXISTING GRADE BEAM)
PILE CAP, REF. PLAN FOR DIMENSIONS
AND SCHEDULE FOR REINFORCING
FIELD VERIFY EXISTING
GRADE BEAM DEPTH
EXIST…