2023-08-09 - IHC - Addendum 2.pdf
PDF 9 MB Posted
- Solicitation number
- 36C77623B0037
About this file
This is a solicitation for project number 626-309 to construct an integrated health center at the Alvin C. York VA Medical Center campus in Murfreesboro, Tennessee. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, seeking construction services including interior demolition, renovation of approximately 37,000 square feet, and building additions totaling 4,654 square feet. The project involves converting existing spaces such as an auditorium, recreation hall, swimming pool, and gymnasium into therapy areas, classrooms, and administrative offices. Existing areas including a cafeteria, kitchen, mechanical and electrical rooms will remain.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/8
/2
:2
:5
P M
GI 00.01
COVER SHEET TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA
PHONE: 615.370.8500
CITY/STATE/ZIP: BRENTWOOD, TN 37027
ADDRESS 214 CENTERVIEW W. DRIVE, STE 300
EMAIL: BCRUMP@WOLDHFR.COM
STRUCTRUAL
ENGINEER:
DESIGNER: BRIAN CRUMP
WEB: www.hfrdesign.com
FAX: 615.370.8530
PHONE: 615.370.8500
CITY/STATE/ZIP: BRENTWOOD, TN 37027
ADDRESS: 214 CENTERVIEW DRIVE, STE 300
EMAIL: GNEWMAN@WOLDHFR.COM
DESIGNER: GISELLE NEWMAN
INTERIOR
DESIGNER:
WOLD | HFR DESIGN
PROJECT NUMBER: 217040
WEB: www.woldhfrdesign.com
FAX: 615.370.8530
PHONE: 615.370.8500
CITY/STATE/ZIP: BRENTWOOD, TN 37027
ADDRESS: 214 CENTERVIEW DRIVE, STE 300
EMAIL: ATRAYLOR@WOLDHFR.COM
PROJ. MANAGER: ANTHONY TRAYLOR
EMAIL: RFRANKS@WOLDHFR.COM
PRINCIPAL: RON FRANKS
ARCHITECT: WOLD | HFR DESIGN
PHONE: (828) 315-9962
ADDRESS: 102 3RD AVE. NE, HICKORY, NC 28601
EMAIL: ED.HENSON@ATRIAXGROUP.COM
CONTACT: ED HENSON
ARCHITECT: ATRIAX GROUP
PROJECT NUMBER: 626-309
PHONE: 615.867.6000
CITY/STATE/ZIP: Murfreesboro, TN 37129
ADDRESS: 3400 Lebanon Road
EMAIL: HANS.JOHNSON2@VA.GOV
CONTACT PERSON: HANS JOHNSON
COR: VA
PROJECT CONTACT LIST
PHONE: (828) 315-9962
ADDRESS: 102 3RD AVE. NE, HICKORY, NC 28601
EMAIL: justing.keneer.atriaxgroup.com
CONTACT: JUSTIN KENEER
CIVIL: ATRIAX GROUP
WEB: www.tlc-engineers.com
FAX: 615.297.4554
PHONE: 615.297.4554
CITY/STATE/ZIP: BRENTWOOD, TN 37027
ADDRESS: 12 CADILLIAC DRIVE, SUITE 150
EMAIL: DERON.MCINTOSH@tlc-eng.com
ELECTRICAL: DERON MCINTOSH
EMAIL: STEVE.KEMP@tlc-eng.com
PLUMBING: STEVE KEMP
EMAIL: STEVE.KEMP@tlc-eng.com
MECHANICAL: STEVE KEMP
MECHANICAL,
PLUMBING, &
ELECTRICAL
ENGINEERS:
TLC ENGINEERING SOLUTIONS
PROJECT CONTACTS (CONT)
ARCHITECTS / STRUCTURAL
WOLD | HFR DESIGN ATRIAX GROUP
ARCHITECT / CIVIL
TLC ENGINEERING
MECHANICAL/ELECTRICAL/PLUMBING/TECHNOLOGY
DEPARTMENT OF VETERANS AFFAIRS
TVHS - ALVIN C. YORK VAMC - INTEGRATED HEALTH CENTER
3400 LEBANON PIKE
MURFREESBORO, TN 37130
PROJECT NO. 626-309
05-20-2022
100% CONSTRUCTION DOCUMENTS
W O
L D
H
F R
D E
S
IG
N
-2
-2
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
Revisions: Date:
Addendum 1 07/17/2023
Addendum 2 08/08/2023
INCLUDES ADDENDUM #1 - 07/17/2023
INCLUDES ADDENDUM #2 - 08/092023
WINDOW TAG
ELEVATION TAG
GYPSUM BOARD
CONCRETE
CONC. MASONRY UNITS
FINISH WOOD
BATT INSULATION
HANDICAP ACCESSIBLE
SECTION INDICATOR
SHEET NUMBER
ENLARGED PLAN NUMBER
NOTE: THE DIRECTION OF THE SECTION INDICATOR'S
FLAG MAY REFLECT AN "OPPOSITE HAND" OR
"MIRRORED VIEW" OF BUILDING AND WALL SECTIONS
EQUIPMENT TAG
A
CALLOUT TAG
# / A ##.##
# / A ##.##
# / A ##.##
0000-000
EXIST DEMO NEW
CONTINUOUS LINE
MEDIUM DASH LINE
0 4' 8' 12'
BREAK, ROUND (USER DEFINES SIZE)
BREAK, STRAIGHT
(SEE SECTION INDICATORS,
BUILDING, WITH BREAK STANDARDS)
DETAIL INDICATOR
DIMENSION LINE
DOOR OPENING/
BORROWED LIGHT IDENTIFIER
NORTH
DETAIL INDICATOR
FURNITURE, FIXTURE, &
EQUIPMENTS INDICATOR
GRAPHIC SCALE, 1/8" = 1'-0"
ROOM NAME AND NUMBER
COLUMN GRID
KEYNOTE
FIRE EXTINGUISHER CABINET
NORTH ARROW
WALL OR PARTITION TYPE
CORNER GUARD
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION
TO BE REMOVED
NEW CONSTRUCTION
VV ITEM - VA SUPPLIED & INSTALLED
VC ITEM - VA SUPPLIED &
CONTRACTOR INSTALLED
CC ITEM - CONTRACTOR SUPPLIED &
INSTALLED
DETAIL NUMBER
SHEET WHERE REF.
SHEET WHERE DRAWN
FEC
AA
A
CG
CORRIDOR
C2
A3.1 A4.3
D2
A-512
101A
DOOR TAG
DRAWING BLOCK TITLE, TYPICALFLOOR PLAN1
RIGID INSULATION
EARTH
BASE COURSE
PROJECT LOCATION
PROJECT LOCATION
CONSTRUCTION TYPE: IIB, AUTOMATIC SPRINKLER SYSTEM, ALLOWED AREA:
OCCUPANCY GROUP: ALLOWED AREA
(1 STORY):
MAX
FRONTAGE
INCREASE
ALLOWED AREA
W/ INCREASE:
A-2 ASSEMBLY
A-3 ASSEMBLY
B - BUSINESS
M- MERCANTILE
7,125 SF =
7,125 SF =
17,250 SF =
9,375 SF =
38,000 SF +
38,000 SF +
92,000 SF +
50,000 SF +
45,125 SF - MOST
RESTRICTIVE
45,125 SF - MOST
RESTRICTIVE
109,250 SF
59,375 SF
CONSTRUCTION TYPE: II (0,0,0) AUTOMATIC SPRINKLER SYSTEM, ALLOWANCES/RESTRICTIONS:
2021 NFPA 101:
NEW AND EXISTING
ASSEMBLY
NEW AND EXISTING
BUSINESS
TABLE 12.1.6 AND
TABLE 13.1.6
SEC. 38.6.1 AND SEC.
39.6.1
- 1 STORY ALLOW FOR ANY OCCUPANT LOAD
2 STOIRES ALLOWED FOR AN OCCUPANY LOAD
OF 300 OR LESS.
NO MIN. CONSTRUCTION REQUIREMENTS
NEW AND EXISTING
MERCANTILE
SEC. 36.6.1 AND SEC.
37.6.1
NO MIN. CONSTRUCTION REQUIREMENTS
2021 IBC:
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/9
/2
:1
:4
P M
GI 01.01
GENERAL DATA TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA
SYMBOL LEGEND
MECH. MECHANICAL
MED. MEDICAL
MED. CAB. MEDICAL CABINET
MFR. MANUFACTURER
MGMT. MANAGEMENT
MH MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
MR/S MIRROR WITH SHELF
MTD. MOUNTED
MTL. METAL
N.I.C. NOT IN CONTRACT
NOM. NOMINAL
O.C. ON CENTER
O.D. OVERFLOW DRAIN
O.F.O.I. OWNER FURNISHED / OWNER
INSTALLED
OPER. OPERATIONS
OPNG. OPENING
OPP. OPPOSITE
P.P.G. POLISHED PLATE GLASS
P.R.V. POWER ROOF VENTILATOR
P.T. PRESSURE TREATED
PART'N(S) PARTITION(S)
PLAS. PLASTER
PLAS. LAM. PLASTIC LAMINATE
PLYWD. PLYWOOD
PREP. PREPARATION
PREV. PREVENTIVE
PROF. PROFESSIONAL
PTD PAPER TOWEL DISPENSER
Q.T. QUARRY TILE
R. RADIUS
R.D. ROOF DRAIN
R.O. ROUGH OPENING
RECEPT. RECEPTION
RECOV. RECOVERY
REF. REFRIGERATOR
REF. REFER, REFERENCE
REINF. REINFORCING, REINFORCED
REQ'D REQUIRED
RM. ROOM
S SEALANT
S.&R. SHELF AND ROD
SAN. SANITARY
SB SPLASHBLOCK
SCHED. SCHEDULE
SD SOAP DISPENSER
SEC. SECTION, SECRETARY
SGNL. SIGNAL
SHLVG. SHELVING
SIM. SIMILAR
SPECS. SPECIFICATIONS
SS STAINLESS STEEL
STD. STANDARD
STL. STEEL
STO. STORAGE
STRUCT. STRUCTURAL
SYS. SYSTEM
T./TOIL./TL
T.
TOILET
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
TB TOWEL BAR
TBL. TABLE
TECH. TECHNICIAN
TEL. TELEPHONE
THK. THICK
THKNS. THICKNESS
TPD TOILET PAPER DISPENSER
TRAIN. TRAINING
TRANS. TRANSFORMER
TREAT. TREATMENT
TYP. TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
UNEXP. UNEXPOSED
VEST. VESTIBULE
W.H.F.E. WALL HUNG FIRE
EXTINGUISHER
W/ WITH
WC/W.C. WATER CLOSET
WD. WOOD
WP WATERPROOF(ING)
WP WALL PROTECTION
A.F.F. ABOVE FINISHED FLOOR
A.F.S. AT FINISHED SLAB
ACT ACOUSTICAL CEILING TILE
ADD'L ADDITIONAL
ADJ. ADJUSTABLE
ADMIN. ADMINISTRATION
ALUM. ALUMINUM
APPROX. APPROXIMATE
ASST. ASSISTANT
B.W. BOTTOM OF THE WALL
B/B BALLED & BURLAPPED
BR. BARE ROOT
BRKT. BRACKET
BRKTS. BRACKETS
C CALK
C'SNK. COUNTERSUNK
C.B. CATCH BASIN
C.F.C.I. CONTRACTOR FURNISHED /
CONTRACTOR INSTALLED
C.J. CONTROL JOINT
C.M.U. CONCRETE MASONRY UNIT
CAB. CABINET
CLG. CEILING
CLO. CLOSET
CNTR. COUNTER
COL. COLUMN
COMP. COMPUTER
CONC. CONCRETE
CONF. CONFERENCE
CONST. CONSTRUCTION
CONT. CONTINUOUS
CORR. CORRIDOR
DIA. DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DIR. DIRECTOR
DISP. DISPENSER
DS DOWNSPOUT
DTL. DETAIL
DWGS. DRAWINGS
EA. EACH
ELEC. ELECTRICAL
ELEV. ELEVATION
ENCL. ENCLOSURE
EQ EQUAL
EQUIP. EQUIPMENT
EXIST. EXISTING
EXP. JT. EXPANSION JOINT
EXT. EXTERIOR
F.D. FLOOR DRAIN
F.E.C. FIRE EXTINGUISHER CABINET
F.F.E. FINISH FLOOR ELEVATION
FDS FOLD DOWN SEAT
FH FIRE HYDRANT
FIN. FINISH
FL. FLOOR
FOB FACE OF BRICK
FTG. FOOTING
FZR. FREEZER
G.B. GRAB BAR
GA. GAUGE
GAL. GALLON
GALV. GALVANIZED
GEN. GENERAL
GYP. GYPSUM
GYP. BD. GYPSUM BOARD
H.B. HOSE BIBB
H.M. HOLLOW METAL
HD. HEAD
HRDBD HARDBOARD
I.D. INSIDE DIAMETER
INFO. INFORMATION
INSUL. INSULATION
INT. INTERIOR
INV. INVERT
JT. JOINT
KIT. KITCHEN
LAB. LABORATORY
LAV. LAVATORY
LKR. LOCKER
M.O. MASONRY OPENING
MACH. MACHINE
MAINT. MAINTENANCE
MAT'L MATERIAL
MAX. MAXIMUM
GENERAL ABBREVIATIONS
● ALL OTHER NON-STRUCTURAL COMPONENTS WITHIN THE HVAC, MECHANICAL, PLUMBING, AND
ELECTRICAL SYSTEMS ARE ASSIGNED AN IMPORTANCE FACTOR OF 1.0 AND ARE ELIGIBLE FOR THE LATERAL BRACING EXEMPTIONS LISTED IN ASCE 7 SECTION 9.6. THE EXEMPTIONS APPLY TO SPECIFIC SMALLER SIZES OF PIPING AND DUCTWORK AND LESS HEAVY EQUIPMENT. NON-EXEMPT PORTIONS OF THESE SYSTEMS SHALL STILL BE LATERALLY BRACED. SYSTEMS WITH AN IMPORTANCE FACTOR OF 1.0
ARE CONSIDERED BY THE CODE TO BE NOT CRITICAL FOR THE CONTINUED OPERATION OF THE
FACILITY.
COMPONENTS WITH AN IMPORTANCE FACTOR OF 1.0:
● STORM SEWER SERVING CRITICAL CARE AREAS.
● SANITARY SEWER SERVING CRITICAL CARE AREAS.
● STEAM SYSTEM.
● HEATING HOT WATER SYSTEM.
● DOMESTIC HOT WATER SYSTEM.
● FIRE ALARM SYSTEM.
● EMERGENCY POWER DISTRIBUTION SYSTEMS INCLUDING ASSOCIATED GENERATOR, TRANSFER
SWITCHES, BUS DUCTS, SWITCHBOARDS, CONDUIT, AND TRANSFORMERS.
● GENERATOR ENGINE EXHAUST.
● DUCTWORK CARRYING RADIOACTIVE AGENTS AND INFECTIOUS ISOLATION AIR.
● MEDICAL GAS PIPING AND EQUIPMENT.
● FIRE SPRINKLERS AND EQUIPMENT.
● NATURAL GAS PIPING.
● FUEL OIL PIPING AND EQUIPMENT.
COMPONENTS WITH AN IMPORTANCE FACTOR OF 1.5:
3. ASSIGNED SEISMIC USE GROUP OR BUILDING DESIGN CATEGORY AS DEFINED IN THE IBC:
2. THE TERM "WITHSTAND" MEANS "THE SYSTEM WILL REMAIN IN PLACE WITHOUT SEPARATION OF ANY PARTS WHEN SUBJECTED TO THE SEISMIC FORCES SPECIFIED AND THE SYSTEM WILL BE FULLY OPERATIONAL
AFTER THE SEISMIC EVENT."
1. COMPONENTS SHALL WITHSTAND THE EFFECTS OF EARTHQUAKE MOTIONS DETERMINED ACCORDING TO
ASCE/SEI 7.
NON-STRUCTURAL SEISMIC NOTES
14. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL LOCAL AND STATE CONSTRUCTION PERMITS.
13. CONTRACTOR SHALL NOT DISRUPT OR LIMIT THE FACILITY'S LIFE SAFETY PLAN AND SYSTEM.
12. SEISMIC: NON-STRUCTURAL COMPONENTS SHALL WITHSTAND THE EFFECTS OF EARTHQUAKE MOTIONS
DETERMINED ACCORDING TO ASCE/SEI 7. PROVIDE ENGINEERED SUPPORTS PER SEISMIC
CLASSIFICATION AND ASCE/SEI 7 REQUIRMENTS.
11. CODES: COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES.
10. SUPPORT / BLOCKING: PROVIDE SUPPORT FOR NEW WORK. IF HANGERS, BACKERS, OR OTHER SUPPORTS ARE NOT DETAILED, NOTED, OR SPECIFIED, CONTRACTOR SHALL SUBMIT A VIABLE SUPPORT
DETAIL TO THE ARCHITECT FOR APPROVAL. ALL BLOCKING SHALL BE METAL (U.N.O.)
9. MAINTAIN RATINGS: MAINTAIN FIRE / SMOKE RATINGS OF EXISTING PARTITIONS AND BARRIERS.
8. SHUTDOWNS / DOWNTIME: CONTRACTOR SHALL MAKE EVERY EFFORT TO MINIMIZE DOWNTIME
ASSOCIATED WITH SCHEDULED SHUTDOWNS. COORDINATE WITH COR.
7. COORDINATE TRADES: GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION BETWEEN
TRADES. MECHANICAL DUCTWORK & EQUIPMENT SHALL HAVE PRIORITY OVER OTHER DISCIPLINES (FOR INSTALLATION & ROUTING). COORDINATE UTILITIES, SO THEY ARE INSTALLED IN AN ORDERLY AND
UNIFORM MANNER.
6. PROTECT / RESTORE: PROTECT EXISTING ITEMS, EQUIPMENT, FINISHES, ETC., TO REMAIN. REPAIR / REPLACE / RESTORE CONDITIONS THAT ARE DAMAGED OR DISTURBED AS A RESULT OF DEMOLITION OR
NEW WORK.
5. UTILITIES: UTILITIES AND SYSTEMS IN AREAS OUTSIDE THE CONSTRUCTION LIMITS SHALL REMAIN (U.N.O.).
4. COORDINATE NEW ITEMS: EXACT LOCATIONS OF ALL EQUIPMENT, DEVICES / OUTLETS, FIXTURES, CASEWORK, MOUNTS, AND ROUTING OF UTILITIES SHALL BE COORDINATED WITH AND APPROVED BY THE
COR.
3. DO NOT SCALE DRAWINGS.
2. VERIFY CONDITIONS: INVESTIGATE THE SITE AND VERIFY EXISTING CONDITIONS (BOTH EXPOSED AND
CONCEALED) PRIOR TO PRICING THE JOB.
1. DIAGRAMMATIC DRAWINGS: THE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE DRAWINGS
REPRESENT THE INTENT OF THE PROJECT WORK.
GENERAL PROJECT NOTES
ROOF CONSTRUCTION: 0 HR
FLOOR CONSTRUCTION: 0 HR
NON-BEARING WALLS & PARTITIONS (INTERIOR): 0 HR
NON-BEARING WALLS & PARTITIONS (EXTERIOR) 0 HR
BEARING WALLS (INTERIOR): 0 HR
BEARING WALLS (EXTERIOR): 0 HR
STRUCTURAL FRAME: 0 HR
H. FIRE PROTECTION REQUIREMENTS (IBC TABLE 601 & NFPA A.8.2.1.2):
DEAD ENDS GROUPS B, & M: 50 FEET MAX
DEAD ENDS GROUP A: 20 FEET MAX IBC/NFPA
CORR. FIRE RATING OCCUPANCY: 0 HRS (SPRINKLERED) IBC/NFPA
CORRIDORS: WIDTH: 96 IN IBC/NFPA
TRAVEL GROUPS B, & M: 100 FT
MAX COMMON PATH: TRAVEL GROUP A: 20 FT (75 FT IF NO
MORE THAN 50
OCCUPANTS)
IBC/NFPA
DISTANCE GROUP B: 300 FT (SPRINKLERED)
MAX EGRESS: DISTANCE GROUPS A, & M: 250 FT (SPRINKLERED) IBC/NFPA
EGRESS WIDTH: 0.2 PER OCCUPANT DOORS (OTHER) IBC/NFPA
G. EXIT REQUIREMENTS:
NOTE: REFRENCE TABLE ON SHEET GI 02.01
F. OCCUPANT LOAD:
PROPOSED HEIGHT: NO CHANGE
EXISTING HEIGHT: 49 FEET, VARIES
EXISTING SITE ADDITION AREA: 234 SF
PROPOSED MECH. EQUIP PLATFORM TOTAL AREA: 4,654 SF
PROPOSED MECH. EQUIP PLATFORM BUILDING
ADDITIONS AREA:
2,532 SF
PROPOSED MECH. EQUIP PLATFORM RENOVATION... 2,122 SF
EXISTING MECH. EQUIP PLATFORM AREA: 2,122 SF
PROPOSED GROUND FLOOR TOTAL AREA: 48,058 SF
PROPOSED GROUND FLOOR OUT OF SCOPE AREA: 11,243 SF
PROPOSED GROUND FLOOR BUILDING ADDITIONS AREA: 1,018 SF
PROPOSED GROUND FLOOR RENOVATION AREA: 35,797 SF
EXISTING GROUND FLOOR AREA: 47,040 SF
REFER TO THE CHART BELOW FOR SPECIFIC OCCUPANCY AREAS
ALLOWED AREA: 38,000 SF+ 7,125 SF FRONTAGE = 45,125 TOTAL (A-3 -
MOST RESTRICTIVE)
ALLOWED HEIGHT: 75' (A-3 - MOST RESTRICTIVE) IBC TABLE 504.3
E. BUILDING HEIGHT & AREA:
SEISMIC DESIGN CAT: B
SITE CLASSIFICATION: C
OCCUPANCY CAT: II
S1 = .124 Sd1 = .124
Ss = .246 Sds = .213
SITE CLASSIFICATION:
D. SEISMIC ZONE:
NFPA 220 - 2021: TYPE II (0,0,0) - FULLY SPRINKLERED NFPA 220,2021
IBC 2021: TYPE II-B - FULLY SPRINKLERED IBC TABLE 601
C. CONSTRUCTION TYPE:
NFPA 2021 : BUSINESS, ASSEMBLY, MERCANTILE
IBC 2021: MIXED OCCUPANCY - BUSINESS - B, ASSEMBLY - A3,
MERCANTILE - M
IBC 2021 SECTION 301
B. OCCUPANACY:
PH: 800-698-2411
WASHINGTON DC 20420
810 VERMONT AVE. NW
VETERANS ADMINISTRATION
A. AUTHORITIES HAVING JURISDICTION (AHJ):
DESCRIPTION: THIS PROJECT INCLUDES INTERIOR DEMOLITION AND RENOVATION OF
APPROXIMATELY 37,000 SF OF BUILDING 107 ON THE YORK VAMC CAMPUS.
RENOVATIONS INCLUDE CONVERTING A LARGE AUDITORIUM, RECREATION HALL,
AND INTERIOR SWIMMING POOL AREA AND A GYMNASIUM INTO THERAPY AREAS,
MULTIPURPOSE ROOMS, CLASSROOMS AND ADMINISTRATION AREAS. EXISTING
CAFETERIA, KITCHEN, MERCANTILE AREA, CHILLER PLAN AREA AND OTHER
MECHANICAL AND ELECTRICAL AREAS ARE TO REMIAN.
3400 LEBANON PIKE, MURFREESBORO,
TN 37130
LOCATION: TVHS - ALVIN C. YORK VAMC
PROJECT: TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
PLAN REVIEW DATA DRAWING INDEX
SHEET # SHEET NAME
SUBMISSIONS REVISIONS
S D
D D
C D
C D 2 1 2
P-PD-05 SECOND FLOOR - DEMOLITION PLAN - PLUMBING ● ●
P-PP-00 BASEMENT - NEW WORK PLAN - GRAVITY - OVERALL ● ●
P-PP-00B BASEMENT - NEW WORK PLAN - GRAVITY - AREA B ● ● ●
P-PP-0A1 UNDERGROUND - NEW WORK PLAN - GRAVITY - AREA A ● ●
P-PP-0B1 UNDERGROUND - NEW WORK PLAN - GRAVITY - AREA B ● ●
P-PP-01 GROUND FLOOR - NEW WORK PLAN - GRAVITY - OVERALL ● ● ●
P-PP-01A GROUND FLOOR - NEW WORK PLAN - GRAVITY - AREA A ● ● ●
P-PP-01B GROUND FLOOR - NEW WORK PLAN - GRAVITY - AREA B ● ● ●
P-PP-11 GROUND FLOOR - NEW WORK PLAN - PRESSURE - OVERALL ● ● ●
P-PP-11A GROUND FLOOR - NEW WORK PLAN - PRESSURE - AREA A ● ● ●
P-PP-11B GROUND FLOOR - NEW WORK PLAN - PRESSURE - AREA B ● ● ●
P-PP-22A SECOND FLOOR - PLUMBING - AREA A ● ● ●
P-PP-22B SECOND FLOOR - PLUMBING - AREA B ● ● ●
P-PP-33 ROOF PLAN PLUMBGING OVERALL ● ●
P-PW-01 PLUMBING RISER - GRAVITY ●
P-PW-02 PLUMBING RISER - PRESSURE ●
10 - ELECTRICAL
E-EI-00 ELECTRICAL LEGEND, LIGHTING SCHEDULE, AND GENERAL NOTES ● ● ● ●
E-EI-02 PARTIAL ELECTRICAL ONELINE - NEW WORK ● ● ● ●
E-EI-03 ELECTRICAL PANEL SCHEDULES ● ● ●
E-EI-04 ELECTRICAL PANEL SCHEDULES ● ● ●
E-EI-05 ELECTRICAL PANEL SCHEDULES ● ● ● ●
E-EI-07 ELECTRICAL DETAILS ● ● ●
E-EI-08 ELECTRICAL DETAILS ● ● ●
E-EI-09 ELECTRICAL DETAILS ● ● ●
E-ES-01 ELECTRICAL SITE PLAN ●
E-ED-20 GROUND FLOOR - DEMO PLAN - ELECTRICAL - OVERALL ● ● ●
E-EL-00 GROUND FLOOR - NEW WORK PLAN - LIGHTING - OVERALL ● ● ●
E-EL-01 GROUND FLOOR - NEW WORK PLAN - LIGHTING - PART A ● ● ●
E-EL-02 GROUND FLOOR - NEW WORK PLAN - LIGHTING - PART B ● ● ●
E-EP-00 GROUND FLOOR - NEW WORK PLAN - POWER - OVERALL ● ● ● ●
E-EP-01 GROUND FLOOR - NEW WORK PLAN - POWER - PART A ● ● ●
E-EP-02 GROUND FLOOR - NEW WORK PLAN - POWER - PART B ● ● ●
E-EP-03 SECOND FLOOR - NEW WORK PLAN - POWER - OVERALL ● ● ●
E-EY-00 GROUND FLOOR - NEW WORK PLAN - SYSTEMS - OVERALL ● ● ●
E-EY-01 GROUND FLOOR - NEW WORK PLAN - SYSTEMS - PART A ● ● ●
E-EY-02 GROUND FLOOR - NEW WORK PLAN - SYSTEMS - PART B ● ● ●
11 - FIRE PROTECTION
F-FI-01 FIRE PROTECTION LEGENDS, DETAILS & NOTES ● ● ● ●
F-FD-01 BASEMENT - DEMOLITION PLAN - FIRE PROTECTION OVERALL ● ● ● ●
F-FD-02 GROUND FLOOR - DEMOLITION PLAN - FIRE PROTECTION OVERALL ● ● ● ●
F-FD-03 SECOND FLOOR - DEMOLITION - FIRE PROTECTION ● ● ● ●
F-FX-01A GROUND FLOOR - NEW WORK PLAN - FIRE PROTECTION - AREA A ● ●
F-FX-01B GROUND FLOOR - NEW WORK PLAN - FIRE PROTECTION - AREA B ● ●
F-FX-02A SECOND FLOOR - NEW WORK PLAN - FIRE PROTECTION - AREA A ● ●
F-FX-02B SECOND FLOOR - NEW WORK PLAN - FIRE PROTECTION - AREA B ● ●
12 - TECHNOLOGY
T-TJ-00 GENERAL TECHNOLOGY INFORMATION ● ● ● ●
T-TD-00 BASEMENT - DEMOLITION PLAN - OVERALL ● ● ● ●
T-TD-01 GROUND FLOOR - DEMOLITION PLAN - OVERALL ● ● ● ●
T-TJ-01 GROUND FLOOR - NEW WORK PLAN - TECHNOLOGY - OVERALL ● ● ● ●
T-TJ-01A GROUND FLOOR - NEW WORK PLAN - TECHNOLOGY - AREA A ● ● ●
T-TJ-01B GROUND FLOOR - NEW WORK PLAN - TECHNOLOGY - AREA B ● ● ●
T-TJ-04 TECHNOLOGY - ENLARGED ROOMS ● ● ●
T-TJ-05 TECHNOLOGY - ENLARGED ROOMS ● ● ● ●
T-TJ-06 TECHNOLOGY - ENLARGED ROOMS ● ● ● ●
T-TJ-07 TECHNOLOGY - DETAILS ● ● ● ●
T-TJ-08 TECHNOLOGY - DETAILS ● ● ● ●
T-TJ-09 TECHNOLOGY - RISER ● ● ● ●
T-TJ-10 TECHNOLOGY - A-V SCHEMATIC FUNCTIONAL DIAGRAM ● ● ●
DRAWING INDEX
SHEET # SHEET NAME
SUBMISSIONS REVISIONS
S D
D D
C D
C D 2 1 2
AE 10.02 CASEWORK SECTIONS AND MISC DETAILS ● ● ●
AC 11.01 OVERALL REFLECTED CEILING PLAN ● ● ● ●
AC 11.01A GROUND FLOOR REFLECTED CEILING PLAN AREA A ● ● ● ●
AC 11.01B GROUND FLOOR REFLECTED CEILING PLAN AREA B ● ● ● ●
AC 11.02 CEILING DETAILS ● ● ●
AC 11.03 CEILING DETAILS ● ●
QH 12.01A GROUND FLOOR EQUIPMENT PLAN AREA A ● ● ●
QH 12.01B GROUND FLOOR EQUIPMENT PLAN AREA B ● ● ●
05 - INTERIOR DESIGN
IN 01.00 FINISH LEGEND & SCHEDULE ● ● ● ● ●
IN 01.01A GROUND FLOOR FINISH PLAN AREA A ● ● ●
IN 01.01B GROUND FLOOR FINISH PLAN AREA B ● ● ● ●
IN 02.01A GROUND FLOOR PATTERN PLAN AREA A ● ● ●
IN 02.01B GROUND FLOOR PATTERN PLAN AREA B ● ● ●
IN 03.00 SIGNAGE LEGEND ● ●
IN 03.01 SIGNAGE SCHEDULE ● ●
07 - STRUCTURAL
S 1.00 STRUCTURAL NOTES ● ● ●
S 1.01A FOUNDATION PLAN - AREA A ● ● ●
S 1.01B FOUNDATION PLAN - AREA B ● ● ●
S 1.02A LOW ROOF FRAMING PLAN - AREA A ● ● ●
S 1.02B SECOND FLOOR / LOW ROOF FRAMING PLAN - AREA B ● ● ●
S 1.03B ROOF FRAMING PLAN - AREA B ● ● ●
S 4.01 SECTIONS AND DETAILS ● ●
S 4.02 SECTIONS AND DETAILS ● ●
S 4.03 SECTIONS AND DETAILS ● ●
S 4.04 SECTIONS AND DETAILS ●
S 4.51 SECTIONS AND DETAILS ● ●
S 4.52 SECTIONS AND DETAILS ● ●
08 - MECHANICAL
M-MK-01 LEGENDS, NOTES, AND SYMBOLS ● ● ● ●
M-MK-02 SCHEDULES ● ● ●
M-MK-03 SCHEDULES ● ●
M-MK-04 SCHEDULES ●
M-MK-05 SCHEDULES (EXISTING EQUIPMENT) ●
M-MK-06 SCHEDULES ●
M-MD-01 BASEMENT OVERALL - HVAC DEMO ● ● ● ●
M-MD-02 GROUND FLOOR OVERALL - HVAC DEMO ● ● ●
M-MD-03 SECOND FLOOR OVERALL - HVAC DEMO ● ● ●
M-MD-04 ROOF OVERALL - HVAC DEMO ● ●
M-MD-05 AHU-34 & 35 EXISTING PLANS ● ●
M-MH-00 BASEMENT OVERALL - DUCTWORK ● ●
M-MH-01 GROUND FLOOR OVERALL - DUCTWORK ● ● ● ●
M-MH-01A GROUND FLOOR AREA A - DUCTWORK ● ● ●
M-MH-01B GROUND FLOOR AREA B - DUCTWORK ● ● ●
M-MH-02 SECOND FLOOR OVERALL - DUCTWORK ● ● ● ●
M-MH-02A SECOND FLOOR AREA A - DUCTWORK ● ● ●
M-MH-02B SECOND FLOOR AREA B - DUCTWORK ● ● ●
M-MH-03 ROOF PLAN OVERALL - DUCTWORK ● ● ●
M-MH-03-1 ROOF PLAN - OVERALL 3D ● ● ●
M-MH-03A ROOF PLAN - AREA A - DUCTWORK ● ● ●
M-MH-03B ROOF PLAN - AREA B - DUCTWORK ● ● ●
M-MH-04 SECTIONS ●
M-MP-00 BASEMENT OVERALL - PIPING ● ●
M-MP-00A BASEMENT AREA A - PIPING ● ●
M-MP-00B BASEMENT AREA B - PIPING ● ●
M-MP-01 GROUND FLOOR OVERALL - PIPING ● ● ●
M-MP-01A GROUND FLOOR AREA A - PIPING ● ●
M-MP-01B GROUND FLOOR AREA B - PIPING ● ●
M-MP-02 SECOND FLOOR OVERALL - PIPING ● ● ● ●
M-MP-02A SECOND FLOOR AREA A - PIPING ● ●
M-MP-02B SECOND FLOOR AREA B - PIPING ● ●
M-MJ-01 MECHANICAL DETAILS ● ● ● ●
M-MJ-02 MECHANICAL DETAILS ● ● ● ●
M-MJ-03 MECHANICAL DETAILS ● ● ● ●
M-MJ-04 MECHANICAL DETAILS ● ● ● ●
M-MJ-05 MECHANICAL DETAILS ● ●
M-MI-01 MECHANICAL CONTROLS ● ● ● ●
M-MI-02 MECHANICAL CONTROLS ● ● ● ●
M-MI-03 MECHANICAL CONTROLS ● ● ● ●
M-MI-04 MECHANICAL CONTROLS ●
M-MI-05 MECHANICAL CONTROLS ●
M-MI-06 MECHANICAL CONTROLS ●
M-MI-07 MECHANICAL CONTROLS ●
M-MI-08 MECHANICAL CONTROLS ●
09 - PLUMBING
P-PI-01 PLUMBING LEGENDS & NOTES ● ● ● ●
P-PI-02 PLUMBING SCHEDULES ● ● ● ●
P-PI-03 PLUMBING DETAILS ● ● ● ●
P-PI-04 PLUMBING DETAILS ● ● ● ●
P-PD-00 BASEMENT - DEMOLITION PLAN - PLUMBING OVERALL ● ● ● ●
P-PD-01 GROUND FLOOR - DEMOLITION PLAN - GRAVITY - AREA A ● ● ● ●
P-PD-02 SECOND FLOOR - DEMOLITION PLAN - GRAVITY - AREA B ● ● ● ●
P-PD-03 GROUND FLOOR DEMOLITION PLAN - PRESSURE - AREA A ● ●
P-PD-04 GROUND FLOOR DEMOLITION PLAN - PRESSURE - AREA B ● ●
DRAWING INDEX
SHEET # SHEET NAME
SUBMISSIONS REVISIONS
S D
D D
C D
C D 2 1 2
00 - GENERAL
GI 00.01 COVER SHEET ● ● ● ● ● ●
GI 01.01 GENERAL DATA ● ● ● ● ● ●
GI 01.02 WALL TYPE DETAILS ● ● ●
GI 01.03 ACCESSIBILITY DETAILS ● ● ● ●
GI 01.20 EXISTING PLAN/CAMPUS MAP ● ● ●
GI 01.21 OVERALL SCOPE ● ● ●
GI 01.30 SUGGESTED PHASING PLANS ● ● ● ●
GI 01.40 PHASE I ICRA PLAN ● ● ●
GI 01.41 PHASE II ICRA PLAN ● ●
GI 01.42 PHASE III ICRA PLAN ● ●
GI 01.43 PHASE IV ICRA PLAN ● ●
GI 01.44 PHASE V ICRA PLAN ● ●
GI 02.01 OVERALL LIFE SAFETY PLAN ● ● ● ●
GI 01.51 ASBESTOS AND LEAD SAMPLE LOCATION DRAWING ● ●
GI 01.52 ASBESTOS CONTAINING MATERIAL LOCATION DRAWING ● ●
GI 01.53 ASBESTOS CONTAINING MATERIAL LOCATION DRAWING ● ●
GI 01.54 ASBESTOS CONTAINING MATERIAL LOCATION DRAWING ● ●
GI 01.55 ASBESTOS SUMMARY KEYNOTES ● ●
01 - CIVIL
CG101 CIVIL COVER SHEET ●
V-101 EXISTING CONDITIONS PLAN ● ● ●
CD101 DEMOLITION PLAN ● ● ●
C-101 CIVIL SITE PLAN ● ● ●
C-102 GRADING PLAN ● ● ●
C-103 EROSION AND SEDIMENT CONTROL PLAN ● ●
C-104 GRADING AND DRAINAGE PLAN ●
C-201 GRADING AND DRAINAGE PLAN ●
C-501 CIVIL DETAILS 1 ● ● ●
C-502 CIVIL DETAILS 2 ● ● ●
C-503 CIVIL DETAILS 3 ● ● ●
C-504 CIVIL DETAILS 4 ● ●
C-505 CIVIL DETAILS 5 ●
C-506 CIVIL DETAILS 6 ●
C-507 CIVIL DETAILS 7 ●
C-508 CIVIL DETAILS 8 ●
C-509 CIVIL DETAILS 9 ●
03 - DEMOLITION
AD 01.01 PHASE I DEMO PLAN ● ●
AD 01.02 PHASE II DEMO PLAN ● ●
AD 01.03 PHASE III DEMOLITION PLAN ● ●
AD 01.04 PHASE IV DEMOLITION PLAN ● ● ● ● ●
AD 01.05 PHASE V DEMOLITION PLAN ● ●
AD 01.06 DEMO PHOTOS ● ● ● ●
04 - ARCHITECTURAL
AE 01.01 GROUND FLOOR OVERALL PLAN ● ● ● ●
AE 01.01A GROUND FLOOR PLAN AREA A ● ● ● ●
AE 01.01B GROUND FLOOR PLAN AREA B ● ● ● ●
AE 01.01C MECH EQUIP PLATFORMS/TRANSFORMER ● ● ●
AE 01.02 ROOF PLAN ● ● ● ●
AE 01.03 ALTERNATE PLANS ● ●
AE 01.10A GROUND FLOOR PLAN AREA A - DIMENSIONED ● ●
AE 01.10B GROUND FLOOR PLAN AREA B - DIMENSIONED ● ●
AE 02.02 ENLARGED PLANS - VESTIBULE/PMRS CONSULT ● ● ●
AE 02.03 ENLARGED PLANS - SIM LAB ● ● ● ● ●
AE 02.04 ENLARGED PLANS - KINESIO THERAPY ● ● ● ●
AE 02.05 ENLARGED PLANS - TOILETS ● ● ●
AE 02.06 ENLARGED PLANS - TOILETS ● ●
AE 03.01 DOOR ELEVATIONS, SCHEDULE, & NOTES ● ● ●
AE 03.02 DOOR DETAILS ● ● ●
AE 03.03 DOOR DETAILS ● ●
AE 03.04 WINDOW ELEVATIONS & NOTES ● ● ●
AE 03.05 WINDOW DETAILS - INTERIOR ● ●
AE 03.06 WINDOW DETAILS - EXTERIOR ● ● ● ●
AE 04.01 BUILDING ELEVATIONS ● ● ● ●
AE 04.02 BUILDING ELEVATIONS ● ● ●
AE 05.01 BUILDING SECTIONS AREA A ● ● ●
AE 05.02 BUILDING SECTIONS AREA B ● ● ●
AE 06.01 WALL SECTIONS ● ● ●
AE 06.02 WALL SECTIONS ● ● ●
AE 08.01 EXTERIOR DETAILS ● ● ● ●
AE 08.02 EXTERIOR DETAILS ● ● ●
AE 08.03 PLAN DETAILS ● ●
AE 08.04 PLAN DETAILS ● ●
AE 08.05 MISC. DETAILS ● ● ●
AE 08.06 MISC DETAILS ● ● ●
AE 08.07 RAMP DETAILS ● ● ●
AE 08.08 MISC. INTERIOR DETAILS ● ● ●
AE 08.09 MISC. INTERIOR DETAILS ● ● ●
AE 09.01 INTERIOR ELEVATIONS ● ● ●
AE 09.02 INTERIOR ELEVATIONS ● ● ●
AE 09.03 INTERIOR ELEVATIONS ● ● ●
AE 09.04 INTERIOR ELEVATIONS ● ● ● ●
AE 09.05 INTERIOR ELEVATIONS ● ● ●
AE 09.06 INTERIOR ELEVATIONS ● ● ● ●
AE 10.01 CASEWORK SECTIONS AND MISC DETAILS ● ● ●
T. SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE STANDARD 15-2007.
S. VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE STANDARD 62.1-2004.
R. THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL
REQUIREMENTS SECTION 01010 OF THE VA MASTER CONSTRUCTION SPECIFICATION.
Q. EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, AND
TRANSPORTATION MANAGEMENT.
P. FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF
UNDERSTANDING (MOU)
O. DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL
AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL
BUILDINGS, 10 CFR PARTS 433, 434, AND 435.
N ENERGY POLICY ACT OF 2005 (EPACT)
M. MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN SPECIFICATIONS
FOR STRUCTURAL STEEL BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
L. BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN CONCRETE INSTITUTE
AND COMMENTARY (ACI 318)
K. ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN GUIDE (PG-18-13)
J. ASME CODE FOR PRESSURE PIPING
I. ASME BOILER AND PRESSURE VESSEL CODE
H. SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL
ENGINEERS (ASME) A 17.1.
G. INTERNATIONAL PLUMBING CODE (IPC)
F. NATIONAL ELECTRICAL CODE (NEC)
E. VA SEISMIC DESIGN REQUIREMENTS, H-18-8
D. OCCUPATION, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
C. NFPA NATIONAL FIRE CODES, WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900
B. NFPA 101 - 2021 LIFE SAFETY CODE
A. INTERNATIONAL BUILDING CODE (IBC 2021) (ONLY WHEN SPECIFICALLY REFERENCED IN VA
DESIGN DOCUMENTS)
THE LATEST EDITIONS OF THE FOLLOW CODES SHALL BE FOLLOWED.
VA CODE LIST
VICINITY MAP
Revisions: Date:
Addendum 1 07/17/2023
Addendum 2 08/08/2023
UP
UP
DEMO LEGEND
WALL TO BE DEMOLISHED
DOOR/FRAME TO BE DEMOLISHED
EXISTING PARTITION TO REMAIN
PLUMBING FIXTURES TO BE DEMOLISHED
DEMO AERA OUTSIDE OF WARD
02.88
02.87
02.13
02.96
02.94
02.13 02.9702.97
02.9702.97
02.77
02.99
02.18
02.79
02.78 02.18
02.81
02.92
02.73
BASEMENT ACCESS
02.87
02.91
02.89
02.89
ELECTRICAL
STAIRS
WORK ROOM
DRESS ROOM DRESS ROOM
JAN
STAGE
AUDITORIUM
WOMENLOBBYMENSTORAGE
TRANSFORMER
ENTRANCE
OFFICE SHOWER
THERAPEUTIC POOL/STORAGE
LOCKER
TOILET
TOILET
CORRIDOR
HACLOCKER
STAIR
OFFICESTORAGEOFFICE
EXERCISE/GYMRECREATION HALL
KITCHEN
TLT
02.70
AS PART OF BASE BID,
TRANSFORMER IS TO BE
REMOVED AND RELOCATED.
REFERENCE ELECTRICAL
DRAWINGS FOR MORE
INFORMATION.
02.66 02.8902.89
02.63 02.63
02.63
02.63
02.63
02.63
02.64
02.64
02.64
02.11
02.62
02.68
02.60
02.60
02.60
02.60
C O
R R
ID
O
R T
O B
LD
G
CORRIDOR TO BLDG 7
DN
02.57
02.57
02.56
UP
02.16 02.16
02.1602.16
02.1102.11 02.10
02.10
02.10
02.11
02.16 02.16
02.1602.16
02.17
02.17
02.16
02.16 02.11
02.1102.16
02.16
02.10
02.16
02.28
02.11 02.11
02.10
02.10
02.10
02.10
02.64
02.16
02.16
02.10
02.16
02.16
02.16
02.10
02.16
02.1102.1102.1102.11
02.14
02.1602.10
02.10
02.11
02.16
02.10
02.10 02.16
02.16
02.16
02.16
02.16
02.16
02.16
02.16
02.10
02.10
02.10
02.11
02.10 02.1602.16
02.54
2 02.542
02.55 2
ROOF BELOW
ROOF BELOW
ROOF BELOW
REC THERAPY BELOW
STAIR
STUDIO
FAN ROOM
GENERATOR
RM
REWIND RM PROJECTION ROOM CONTROL RM AMP RM
C O
R R
ID
O
R
AMATEUR
RADIO ROOM
JANITOR
02.11
02.16
02.16
02.10
02.16
02.16
02.10
02.10
02.1002.10
02.16
02.16
02.1602.16
02.16
02.10
02.10
02.10
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
KEYPLAN
AREA A
AREA B
OUT OF
SCOPE
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/9
/2
:1
:3
P M
AD 01.04
PHASE IV DEMOLITION PLAN TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA
DENOTED BY A NUMBER ENCLOSED INSIDE A HEXAGON.
ONLY NOTES APPLICABLE TO THIS SHEET ARE SHOWN.
KEYNOTE SCHEDULE
02.62 ALL EXISTING OVERHEAD STEEL IN PROSCENIUM TO REMAIN AS IS.
02.63 CAREFULLY REMOVE BRICK AS INDICATED BY RED DASHED LINES. STORE THE BRICK IN A
SAFE LOCATION TO BE FREE FROM DAMAGE. THE BRICK IS TO BE REUSED FOR WALL INFILL
IN VARIOUS LOCATIONS AROUND THE BUILDING. REF NEW PLAN FOR LOCATIONS
02.64 REMOVE PORTION OF EXISTING WALL TO ALLOW FOR NEW CASED OPENING. BRACE
EXISTING CMU WALL UNTIL NEW STRUCTURE IS PUT INTO PLACE.
02.66 DEMO EXISTING CONCRETE PAD
02.68 EXISTING LADDER TO ROOF TO REMAIN.
02.70 EXISTING WALL TO REMAIN. MINIMIZE DAMAGE AND PREPARE TO RECEIVE NEW FURRING
WALL.
02.73 REMOVE FINISHES ON STAGE TO EXISTING SLAB ON GRADE. REPAIR ANY DAMAGE TO
EXISTING SLAB
02.77 DEMO EXSITING METAL STAIR AND RAILING.
02.78 REMOVE EXISTING DOOR(S) AND RECESSED WALLS. REF. NEW PLAN FOR DOOR ADDITION
02.79 DEMO EXISTING STAIRS AND RAILING TO FINISH GRADE.
02.81 REMOVE EXISTING DOOR. PREP OPENING TO RECEIVE NEW SLIDING DOOR. REF. FLOOR
PLAN FOR MORE INFORMATION. CAREFULLY REMOVE ANY BRICK AND STORE FREE OF
DAMAGE. THE BRICK IS TO BE REUSED FOR WALL INFILL IN VARIOUS LOCATIONS AROUND
THE BUILDING. REF NEW PLAN FOR LOCATIONS
02.87 CAREFULLY REMOVE BRICK FROM AROUND THE DOOR. STORE THE BRICK IN A SAFE
LOCATION TO BE FREE FROM DAMAGE. THE BRICK IS TO BE REUSED FOR WALL INFILL IN
VARIOUS LOCATIONS AROUND THE BUILDING.
02.88 REMOVE EXISTING CONCRETE STOOP.
02.89 S.T.F.U. BLOCKING TO BE REMOVED BACK TO EXISTING CMU. PREP CMU FOR NEW WALL.
02.91 EXISTING POOL LINER TO REMAIN. REF. STRUCTURAL FOR INFILL MATERIAL
02.92 DEMO HANDRAILS AROUND POOL. REPAIR ANY DAMAGE CAUSED TO EXISTING SLAB.
02.94 EXISTING AUDITORIUM WALLS TO REMAIN.
02.96 REMOVE AND DISPOSE OF ALL SEATS.
02.97 REMOVE ENTIRETY OF CMU WALLS AND ALL ITEMS THAT ARE CONNECTED INCLUDING
LOUVERS, EXIT SIGNS, ETC.
02.99 REMOVE EXISTING DOOR AND FRAME AND PREP OPENING FOR WALL INFILL USING
EXISTING BRICKS SALAVAGED FROM VARIOUS DEMO LOCATIONS
DENOTED BY A NUMBER ENCLOSED INSIDE A HEXAGON.
ONLY NOTES APPLICABLE TO THIS SHEET ARE SHOWN.
KEYNOTE SCHEDULE
02.10 REMOVE EXISTING PARTITIONS, AS INDICATED BY DASHED LINES, ENTIRELY FROM FLOOR
TO HIGHEST POINT. REMOVE ALL APPERTUNANCES AND DISCONNECT ALL MOUNTED
SERVICES. TYPICAL AT ALL DASHED WALLS
02.11 REMOVE ALL PLUMBING FIXTURES, FAUCETS, FITTINGS, TOILET PARTITIONS, AND
ACCESSORIES AS INDICATED BY RED DASHED LINES. CAP UTILITIES PER MEP
REQUIREMENTS (SEE PLUMBING DRAWINGS).
02.13 REMOVE EXISTING FLOOR FINISHES COMPLETELY TO EXISTING CONCRETE FLOOR SLAB,
INCLUDING MASTIC, ADHESIVE AND WALL BASE. PATCH AND LEVEL SLAB AS REQUIRED TO
RECEIVE NEW FLOOR FINISHES. TYPICAL THROUGHOUT FLOOR
02.14 REMOVE EXISTING FLOOR TILE AND CHIP OUT GROUT. PATCH AND LEVEL SLAB AS
REQUIRED TO RECEIVE NEW FLOOR FINISHES.
02.16 REMOVE ENTIRE DOOR ASSEMBLIES AS INDICATED BY RED DASHED LINE. INCLUDING
LEAVES, FRAME AND HARDWARE.
02.17 REMOVE ENTIRE DOOR ASSEMBLIES AS INDICATED BY RED DASHED LINE. INCLUDING
LEAVES, FRAME AND HARDWARE. PREP OPENING TO RECEIVE BRICK INFILL
02.18 PROTECT EXISTING ELEMENTS TO REMAIN DURING CONSTRUCTION. PATCH/REPAIR
DAMAGED ELEMENTS DUE TO DEMOLITION OR NEW CONSTRUCTION WITH SIMILAR
ADJACENT MATERIALS.
02.28 REMOVE EXISTING CASEWORK ALONG WITH ALL HARDWARE AND ATTACHED
ACCESSORIES.
02.54 CAREFULLY REMOVE AND SALVAGE EXISTING WALL MURAL. COORDINATE WITH FACILITY
ON STORAGE LOCATION.
02.55 CAREFULLY REMOVE AND SALVAGE ALL INTERIOR SIGNAGE THROUGHOUT THE
DEMOLITION. COORDINATE WITH FACILITY ON STORAGE LOCATION
02.56 REMOVE METAL STAIRS DOWN TO THE BASEMENT.
02.57 REMOVE RAMP DOWN TO EXISTING CONCRETE SLAB.
02.60 CAREFULLY REMOVE A PORTION OF THE BRICK AS INDICATED BY THE DASHED LINES. THE
BRICK IS TO BE REUSED FOR WALL INFILL IN VARIOUS LOCATIONS AROUND THE BUILDING.
REF NEW PLAN FOR LOCATIONS
1/16" = 1'-0"
1 GROUND FLOOR DEMO PLAN PHASE IV
1/16" = 1'-0"
2 MECH EQUIP PLATFORM DEMO PLAN - PHASE IV
2. COORDINATE SCOPE OF DEMOLITION WITH THAT REQUIRED TO INSTALL EQUIPMENT PER VENDOR / COR /
ARCHITECT SPECIFICATIONS.
1. COORDINATE WITH COR ON EQUIPMENT TO BE REMOVED, DISPOSED OF, OR SALVAGED.
EQUIPMENT
3. REPAIR EXISTING SPRAY APPLIED FIRE PROOFING DISTURBED AND/OR DAMAGED DURING CONSTRUCTION.
2. THE INTEGRITY OF RELEVANT STRUCTURAL ELEMENTS SHALL BE MAINTAINED AT ALL TIMES THROUGHOUT
DEMOLITION.
1. CONTRACTOR IS RESPONSIBLE FOR SHORING AND TEMPORARY SUPPORT OF STRUCTURE NECESSARY DUE TO
DEMOLITION.
STRUCTURAL
6. REMOVE DEAD END PIPING AND CONDUIT (FOR EXAMPLE: RISERS WITH NO FLOW, BRANCHES WITH NO FIXTURE).
EMPTY RISERS, MAINS, AND BRANCHES FOR FUTURE USE SHALL REMAIN.
5. VOIDS RESULTING FROM MPE DEMOLITION IN WALL, FLOOR, OR CEILING ASSEMBLIES TO REMAIN SHALL BE
PATCHED WITH SOLID MATERIALS MATCHING ADJACENT CONSTRUCTION.
4. REPAIR EXISTING PIPE AND DUCT INSULATION DAMAGED DURING DEMOLITION.
3. UTILITIES AND SYSTEMS IN AREAS OUTSIDE THE CONSTRUCTION LIMITS SHALL REMAIN (U.N.O.).
2. WHERE SMOKE DETECTORS AND/OR DAMPERS LOCATED IN RATED ASSEMBLIES TO REMAIN ARE REMOVED DURING DEMOLITION, NEW SMOKE DAMPERS AND/OR DETECTORS, INCLUDING ALL ELECTRICAL WIRING, SHALL BE
RE-INSTALLED AT NO COST.
1. COORDINATE REQUIRED SHUTDOWNS OF BUILDING SYSTEMS WITH THE OWNER. SHUTDOWNS SHALL BE DONE AT TIMES MOST CONVENIENT TO THE BUILDING OPERATION, SOME OF WHICH MAY BE DURING NIGHTS OR WEEKENDS.
ALL SHUTDOWNS ARE TO BE SCHEDULED A MINIMUM TWO WEEKS IN ADVANCE. PROVIDE TEMPORARY SERVICES
DURING INTERUPTIONSTOF EXISTING UTILITIES.
MPE SYSTEMS
4. COMPLY WITH REQUIREMENTS OF EPA, CODE OF FEDERAL REGULATIONS, NATIONAL EMISSIONS STANDARDS AND OSHA REGULATIONS ON HAZARDOUS MATERIALS AND ALL OTHER APPLICABLE FEDERAL, STATE AND LOCAL
GOVERNMENT REGULATIONS WHICH ARE INCORPORATED BY REFERENCE.
3. CONTRACTOR SHALL COORDINATE WITH COR ON RESPONSIBILITY OF REMOVAL OF HAZARDOUS MATERIALS
(KNOWN OR UNKNOWN) PRIOR TO SUBMISSION OF BID.
2. IF HAZARDOUS MATERIALS ARE SUSPECTED OR ENCOUNTERED, IMMEDIATELY SUSPEND WORK IN SUSPECTED AREA OF CONTAMINATION, WITHDRAW FROM AREA AND NOTIFY ARCHITECT/ENGINEER AND COR IN WRITING.
1. THE COR IN NO WAY CLAIMS ANY KNOWLEDGE OR RESPONSIBILITY PERTAINING TO THE IDENTIFICATION OR
PROPER AND SAFE REMOVAL OF HAZARDOUS MATERIALS.
HAZARDOUS MATERIALS
2. DO NOT DISABLE OR DISRUPT BUILDING FIRE OR LIFE SAFETY SYSTEMS WITHOUT PRIOR WRITTEN NOTICE TO COR AND LOCAL AUTHORITY HAVING JURISDICTION (AHJ). PROVIDE A MINIMUM OF 3 DAYS NOTICE TO COR PRIOR TO
DISRUPTION. COORDINATE WITH LOCAL AHJ REGARDING NOTICE REQUIREMENTS.
1. ALL NECESSARY PATHS OF EGRESS AND EXITS SHALL BE MAINTAINED 'PROTECTED AND CLEAR' UNLESS ALTERNATE METHODS OF EGRESS ARE PROVIDED THAT ARE ACCEPTABLE TO BUILDING CODE OFFICIALS.
RELOCATE SECURITY DEVICES, FIRE ALARM ITEMS, EXIT SIGNS, AND EMERGENCY LIGHTING AS REQUIRED DUE TO
DEMOLITION OR OBSTRUCTION BY TEMPORARY PARTITIONS.
REGULATORY
2. WHERE EXISTING CONSTRUCTION IS TO BE CUT OR REMOVED, PROVIDE SMOOTH AND STRAIGHT CUT JOINTS THAT ARE STRUCTURALLY SOUND. PATCH AND REPAIR ADJOINING SURFACES TO MATCH EXISTING AND PROVIDE
IMPERCEPTIBLE TRANSITION, (U.N.O.)
● CEILINGS: REMOVE ENTIRE CEILING SYSTEM AND CEILING MOUNTED ITEMS. STORE DEVICES INTENDED
FOR RE-USE.
● WALLS: REMOVE WALL COVERING SYSTEMS SUCH AS PANELING AND VINYL WALL COVERINGS. PATCH /
REPAIR HOLES OR DAMAGED AREAS AND SKIM-COAT ENTIRE SURFACE.
● FLOORS: REMOVE FINISH TO SUB-FLOOR, CLEAN ADHESIVES AND GLUES FROM SUBSTRATE, AND PREPARE
SUBSTRATE (LEVEL AND FILL AS NEEDED).
1. WHERE NEW FINISHES ARE SCHEDULED IN EXISTING SPACES:
ARCHITECTURAL / INTERIORS
7. COORDINATE WITH COR & REMOVE ALL OBSOLETE, UNNECESSARY, OR ABANDONED ITEMS IN DEMOLITION AREAS
THAT ARE NOT APPROPRIATE TO REMAIN FOR NEW WORK.
6. EXISTING CONDITIONS TO REMAIN: DAMAGED COMPONENTS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COST TO THE VA. THIS INCLUDES DAMAGE DONE TO EXISTING SPACES ABOVE, BELOW, AND ADJACENT TO, AS
REQUIRED TO COMPLETE NEW WORK.
5. SURVEY EXISTING CONDITIONS AND CORRELATE WITH REQUIREMENTS INDICATED TO DETERMINE EXTENT OF SELECTIVE DEMOLITION REQUIRED. RECORD EXISTING CONDITIONS BY USE OF ANY COMBINATION OF MEASURED
DRAWINGS AND PRECONSTRUCTION PHOTOGRAPHS.
4. CEASE OPERATIONS IMMEDIATELY IF STRUCTURE APPEARS TO BE IN DANGER AND NOTIFY COR. DO NOT RESUME
OPERATIONS UNTIL DIRECTED.
3. UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS. MAINTAIN FIRE-PROTECTION FACILITIES IN SERVICE DURING
SELECTIVE DEMOLITION OPERATIONS.
2. CONDUCT DEMOLITION TO MINIMIZE INTERFERENCE WITH FACILITY'S NORMAL OPERATIONS AND WITH ADJACENT
BUILDING AREAS.
1. PROVIDE TEMPORARY DUST PARTITIONS, SECURITY DEVICES, AND OTHER MEANS NECESSARY FOR THE PROTECTION OF OCCUPANTS WHERE TRAFFIC IN CORRIDORS AND SPACES ADJACENT TO DEMOLITION / RENOVATION WORK ARE IMPACTED. COORDINATE WITH FACILITY'S INFECTION CONTROL OR COR TO MEET ALL
FACILITY OR REGULATORY REQUIREMENTS RELATED TO PROTECTION OF OCCUPANTS.
EXISTING CONDITIONS
7. REFER TO STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, AND VENDOR (IF APPLICABLE) DRAWINGS AND
SPECIFICATIONS FOR ADDITIONAL DEMOLITION ITEMS AND INFORMATION.
6. EXISTING WARRANTIES: REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND SURFACES CUT OR DAMAGED DURING SELECTIVE DEMOLITION, BY METHODS AND WITH MATERIALS SO AS NOT TO VOID EXISTING WARRANTIES.
5. REMOVED & REINSTALLED ITEMS: CLEAN & REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED USE, PACK OR CRATE AFTER CLEANING / REPAIR AND IDENTIFY CONTENTS OF CONTAINERS, PROTECT ITEMS FROM
DAMAGE DURING TRANSPORT / STORAGE, REINSTALL ITEMS IN LOCATIONS INDICATED.
4. REMOVED & SALVAGED ITEMS: CLEAN ITEMS, PACK OR CRATE AFTER CLEANING AND IDENTIFY CONTENTS OF
CONTAINERS, PROTECT AND TRANSPORT ITEMS TO FACILITY'S STORAGE AREA ON-SITE.
3. REMOVE CONSTRUCTION SHOWN DASHED ON DEMOLITION PLAN. REFERENCE LEGEND FOR MORE SPECIFIC
INFORMATION.
2. PRIOR TO START, HOLD A PRE-DEMOLITION CONFERENCE AT THE PROJECT SITE TO REVIEW METHODS AND PROCEDURES RELATED TO DEMOLITION. COORDINATE WITH COR REGARDING CONSTRUCTION ACCESS, TRANSPORTATION AND DISPOSAL OF DEBRIS, AND OTHER FACILITY REQUIREMENTS RELATED TO CONSTRUCTION.
1. COORDINATE SCOPE OF DEMOLITION WORK TO INSTALL NEW WORK SHOWN ELSEWHERE IN THE CONTRACT DOCUMENTS. (FOR EXAMPLE, IF NEW FINISHES ARE SCHEDULED FOR AN EXISTING AREA TO REMAIN, REMOVE EXISTING FINISHES PRIOR TO INSTALLATION OF NEW FINISHES EVEN IF NOT EXPLICITLY IDENTIFIED ON DEMOLITION
PLAN.)
GENERAL
GENERAL DEMOLITION NOTES
0 8' 16' 32'4'
0 8' 16' 32'4'
NOTE: THIS DRAWING MUST BE
PRINTED IN COLOR FOR AN ACCURATE
DEPICTION OF INFORMATION
Revisions: Date:
Addendum 2 08/08/2023
18 19
F4
F1
AE 05.02
4/ AE 02.03
A
E
.0
A
E
.0
5/ AE 02.03
9/ AE 02.03
A
E
.0
A
E
.0
11/ AE 02.03
A
E
.0
13/ AE 02.03
15/ AE 02.03
MED/SURG SIM LAB
G30D
CONTROL ROOM
G30E
PROCEDURE SIM LAB
G30F
SIM MAINTENANCE
G30G
CORRIDOR
G50
CORRIDOR
G52
CORRIDOR
G30
A
E
.0
E E
F.3
17.4 17.5 18.8 18.9 20.1 20.2
G30D G30E G30F
EMERGENCY EYEWASH
STATION. REF. P-PI-02
SCULLERY SINK. REF. P-PI-02
MANEQUIN STORAGE
RACK, VA PROVIDED AND
INSTALLED
R W
C
R W
C
SLEEPER CHAIR
PATIENT BED
OVERBED TABLE
HIGH BACK CHAIR
INFECTIOUS
WASTE
PATIENT BED
GENERAL CART
STEP STOOL
MAYO STAND
WASTE
COMPUTER CART
EXAM STOOL
BIO WASTE
F3050 - WHITEBOARD,VA PROVIDED
AND INSTALLED
P1
WB
8'-6"
5' -1
0"
WP4
A5106 -
SHARPS/GLOVESC,VA
PROVIDED AND
INSTALLED
30 X 15
2' -1
0"
A5082 - PAPER TOWEL
DISPENSER, VA
PROVIDED AND
INSTALLED
A5075 - SOAP DISPENSER,
VA PROVIDED AND
INSTALLED
30 X 24
30 X 15
SSM1
PL1
PORVIDE SOLID SURFACE END
PANEL TO MATCH SSM1. SEAMS
SHOULD BE SMOOTH TO
RESEMBLE WATERFALL EDGE
WP4
WB
AE 10.01
22" DEEP
5'-1 5/8"
AE 10.01
30 X 23
P1
SCH1 - REFER TO FINISH LEGEND
6" 2'
-0
1' -1
1/ 2"
5" 1'
-7
1/
2"
2'-2" 5'-6" 2'-2"
RWC-2
W A
LL
P
R O
T E
C T
IO
N
4' -0
WP4
P1
WB
WP7
SCH1 - REFER TO FINISH LEGEND
WP2
E
W A
LL
P
R O
T E
C T
IO
N
4' -0
" WP4
WB
P1
SCH1 - REFER TO FINISH LEGEND
EQ EQ
25" DEEP
10'-0"
2' -6
3'
-2
SSM1
MONITORS FOR PATIENT
MONITORING. VA PROVIDED
CONTRACTOR INSTALLED.
P1
WB
2'-1"
COUNTERTOP
SUPPORT
BRACKET
CG1
AE 10.02
E
SSM1
2' -6
P1
WB
3'-0"
COUNTERTOP
SUPPORT
BRACKET
E
2' -6
END PANEL
25" DEEP
SSM1
P1
WB
COUNTERTOP
SUPPORT
BRACKET
COUNTERTOP
SUPPORT
BRACKET
CG1
A5082 - PAPER TOWEL DISPENSER,
VA PROVIDED AND INSTALLED
A5075 - SOAP DISPENSER, VA
PROVIDED AND INSTALLED
P8
INTEGRATED BASE,
MATCH FLOOR TYPE
UP WALL 6"
3' -0
3' -1
1/
2"
4' -0
EMERGENCY EYEWASH STATION.
REF. P-PI-02
SCULLERY SINK. REF. P-PI-02
INTEGRATED BASE,
MATCH FLOOR TYPE
UP WALL 6"
P1
WP4
WP2
E
W A
LL
P
R O
T E
C T
IO
N
4' -0
WP-4
INTEGRATED
BASE, MATCH
FLOOR TYPE UP
WALL 6"
P1
SCH1 -
REFER TO
FINISH
LEGEND
CG1CG1
A5106 - SHARPS/GLOVESC,VA
PROVIDED AND INSTALLED
A5075 - SOAP DISPENSER, VA
PROVIDED AND INSTALLED
A5082 - PAPER TOWEL DISPENSER,
VA PROVIDED AND INSTALLED
WP-4
INTEGRATED BASE, MATCH
FLOOR TYPE UP WALL 6"
W A
LL
P
R O
T E
C T
IO
N
4' -0
P1
SCH1 - REFER TO FINISH LEGEND
5' -9
4' -0
WP-4
INTEGRATED BASE, MATCH FLOOR
TYPE UP WALL 6"
P1
SCH1 - REFER TO FINISH LEGEND
GENERAL NOTE: REFRENCE
IN 01.00 FOR ALL FINISH
NOTES
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/8
/2
:2
:1
P M
AE 02.03
ENLARGED PLANS - SIM LAB TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA
REF: 1 / AE 01.01B
1 G-026/027/030/031 SIMULATION SUITE
REF: 1 / AE 02.03
4 G-30D MED/SURG SIM LAB
REF: 1 / AE 02.03
5 G-30D MED/SURG SIM LAB
REF: 1 / AE 02.03
6 G-30D MED/SURG SIM LAB
REF: 1 / AE 02.03
7 G-30D MED/SURG SIM LAB
REF: 1 / AE 02.03
9 G-30F CONTROL ROOM
REF: 1 / AE 02.03
8 G-30E CONTROL ROOM
REF: 1 / AE 02.03
10 G-30E CONTROL ROOM
REF: 1 / AE 02.03
15 G-031 SIM MAINTENANCE
REF: 1 / AE 02.03
11 G-030F PROCEDURE SIM LAB
REF: 1 / AE 02.03
12 G-030F PROCEDURE SIM LAB
REF: 1 / AE 02.03
13 G-030F PROCEDURE SIM LAB
REF: 1 / AE 02.03
14 G-030F PROCEDURE SIM LAB
0 2' 4' 6'
0 1' 2' 4'6"
0 1' 2' 4'6" 0 1' 2' 4'6"
0 1' 2' 4'6"
0 1' 2' 4'6"
0 1' 2' 4'6" 0 1' 2' 4'6"
0 1' 2' 4'6"
0 1' 2' 4'6"
0 1' 2' 4'6"
0 1' 2' 4'6"0 1' 2' 4'6"
2 MED/SURG SIM LAB G-026 3 PROCEDURE SIM LAB G-030
Revisions: Date:
Addendum 1 07/17/2023
Addendum 2 08/08/2023
M E
D B
A L L
R A
C K
A D
D U
C T
IO
N
/A B
D U
C T
S T
A C
K G
Y M
B A
T C
A F
U S
IO
N
D B
E L
L R
A C
K
R O
W
IN
G M
A C
H
IN
E
S T
A C
K C
A B
L E
S T
A C
K
INCLINE
BENCH
B A
T C
A F
U S
IO
N
D B
E L
L R
A C
K
S T
A C
K G
Y M
S T
A C
K C
A B
L E
B A
C K
E X
T E
N S
IO
N
DBELL
STORAGE
B A
R B
E L L
H O
L D
E R
B A
R B
E L L
H O
L D
E R
W STORAGE
W STORAGE
B O
X
W O
R K
B E
N C
H W
O R
K B
E N
C H
W O
R K
B E
N C
H
INCLINE
BENCH
R O
W
IN
G M
A C
H
IN
E
R O
W
IN
G M
A C
H
IN
E
R O
W
IN
G M
A C
H
IN
E
W A
L L R
A C
K
W H
E E
L
A
E
.0
A
E
.0
4/ AE 02.04
KINESIO GROUP THERAPY
G12
MUSIC STORAGE
G13A
WC STORAGE
G12B
PRACTICE ROOM
G13B
MAT TABLE
STEPPER STEPPER
STEPPER STEPPER
TREADMILL TREADMILL
TREADMILL TREADMILL
WC SCALE
PARALLEL BARS
BIKEBIKEBIKEBIKE
G12B
G12
G12E
G12A
5/ AE 02.04
2'-6" 3'-0" 2'-8" 2'-5" 2'-6" 2'-6" 1'-10 3/4" 4'-0"
A 1040 - DIGITAL LOCKING METAL LOCKERS,
TRIPLE-TIER (18X24) WITH SLOPED TOPS
CONTRACTOR PROVIDED AND INSTALLED.
BASIS OF DESIGN GROUP LACASSE
LOCKERS
2'-6" 3'-0" 2'-9 1/8" 2'-8" 2'-8" 2'-8" 1'-10 5/8"
2'-6" 3'-4" 3'-1 11/16" 2'-6"
1'-6 3/4" 2'-0 5/16"
1'-6 3/4" 2'-0 5/16"
3'-1" 3'-4" 3'-1 1/8" 3'-0" 3'-1"
4'-4 7/8" 2'-0 1/8"
2' -6
3' -0
3' -0
/1
6" 3'
-0
3' -0
4'
-2
/8
2' -0
/1
6"
3' -0
2' -2
/8
1'
-8
/1 6"
1' -8
2'
-1
5/
4' -0
3/
4"
6' -0
2' -1
1/
3' -5
/4
3'-8 7/8"
2'-6 15/16"
7'-4 7/8"
4'-0"
6'-5 7/8"
4'-8 3/4" G12C
G12D
KINESIO GROUP THERAPY
G12
DASHED LINES REPRESENT AREA OF FLOOR TO BE
LEFT OPEN FOR GROUP ACTIVITIES
WORK
BENCH
WORK
BENCH
WORK
BENCH
12"WX18"HX8"D WORK BENCH. PROVIDE
BLOCKING FOR BENCH TO HANG ON WALL
WHEN NOT IN USE. CHECK WITH MANUF.
FOR ANY REQUIRED BRACKETS FOR
HANGING. BENCH IS VA PROVIDED, BRACKET
IS CONTRACTOR INSTALLED
12"WX18"HX8"D WORK BENCH. PROVIDE
BLOCKING FOR BENCH TO HANG ON WALL
WHEN NOT IN USE. CHECK WITH MANUF.
FOR ANY REQUIRED BRACKETS FOR
HANGING. BENCH IS VA PROVIDED, BRACKET
IS CONTRACTOR INSTALLED
12"WX18"HX8"D WORK BENCH. PROVIDE
BLOCKING FOR BENCH TO HANG ON WALL
WHEN NOT IN USE. CHECK WITH MANUF.
FOR ANY REQUIRED BRACKETS FOR
HANGING. BENCH IS VA PROVIDED, BRACKET
IS CONTRACTOR INSTALLED
A P
P R
O X
. L O
C A
T
IO
N O
F B
R A
C K
E T
5' -0
TWO FRAMELESS
STAINLESS STEEL
SHATTERPROOF
MIRRORS STACKED WITH
BASE BEING 6" A.F.F..
EACH MIRROR IS 24" X 36"
BASIS OF DESIGN
BOBRICK B1556 2436 .
PROVIDE BLOCKING AS
REQUIRED. CONRACTOR
PROVIDED AND
INSTALLED. COORDINATE
SO MIRRIOR IS
POSITIONED IN FRONT OF
PARALLEL BARS10'-0" 10'-0"
P6
20'-0"
WB
P1 P1
G12
G12E
A5025 - LOCKER ROOM BENCH
12"X48" - SECURE BENCH TO THE
FLOOR. VA PROVIDED AND
INSTALLED
A 1040 - DIGITAL LOCKING METAL LOCKERS,
TRIPLE-TIER (18X24) WITH SLOPED TOPS
CONTRACTOR PROVIDED AND INSTALLED.
BASIS OF DESIGN GROUP LACASSE
LOCKERS
4' -0
14'-4 1/8"
1' -0
5'
-0
PROVIDE METAL BLOCKING BETWEEN 5' TO
6' UP ON WALL ALONG ENTIRE WALL AS
INDICATED BY DASHED LINES FOR FUTURE
WALL HUNG EQUIPMENT
A P
P R
O X
. M O
U N
T
IN
G H
E
IG
H T
6' -0
SPEED BAG MOUNTED TO THE
WALL. PROVIDE BLOCKING PER
MANUF. INSTRUCTIONS. VA
PROVIDED CONTRACTOR
INSTALLED
P7 P7
WALL MOUNTED WEIGHT RACK.
PROVIDE 14 GAUGE METAL
BLOCKING FOR SUPPORT. RACK IS
VA PROVIDED AND CONTRACTOR
INSTALLED
WALL MOUNTED EXERSIZE WHEEL.
PROVIDE BLOCKING FOR
MOUNTING. MOUNT AT HEIGHT
RECCOMMENDED PER MANF.
INSTRUCTIONS. VA PROVIDED
CONTRACTOR INSTALLED
3' -1
1/
4"
G12DG12C
P1 P1
WB
CG1 CG1 CG1 CG1
G12A
6'-7"
'-6
85" TV MOUNTED TO WALL.PROVIDE
BLOCKING AS REQUIRED. VA PROVIDED
CONTRACTOR INSTALLED.
4'-6" 4'-6" 4'-0"
4' -0
3' -0
2' -0
BARS MOUNTED AT VARYING
HEIGHTS. PROVIDE METAL
BLOCKING AT EACH LOCATION.
BARS ARE VA PROVIDED
CONTRACTOR INSTALLED
P1
WB
DBELL
STORAGE
'-0
85" TV MOUNTED TO WALL.PROVIDE
BLOCKING AS REQUIRED. VA PROVIDED
CONTRACTOR INSTALLED.
G12B
24'-0 1/2"
P1
WB
12 Cadillac Dr., Suite 150 Brentwood, TN 37027 P 615.297.4554
©Copyright 2020
TLC No.:
www.tlc-engineers.com
120483
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
214 Centerview Drive Suite 300 Brentwood, TN 37027
615.370.8500woldhfr.com
WOLD | HFR DESIGN
102 THIRD AVENUE NE
HICKORY, NC 28601
PHONE: 828.315.9962
FAX: 828.315.9966
NC ENGINEERING LICENSE NO: P-0214
NC ARCHITECTURE LICENSE NO: 51254
MURFREESBORO, TN
B
IM
/T
V H
S
A lv in C
Y o rk
V A
I n te g ra te d H e a lt h /2
A R
C H
P
R O
J E
C T
C E
N T
R A
L .r v t
/8
/2
:2
:2
P M
AE 02.04
ENLARGED PLANS - KINESIO
THERAPY
TVHS - ALVIN C. YORK VAMC -
INTEGRATED HEALTH CENTER
AT05-20-2022
626-309
RA
REF: 1 / AE 01.01A
1 G-058 KINESIO GROUP THERAPY
0 2' 4' 6'
3/8" = 1'-0"
2 G-12 KINESIO GROUP THERAPY
3/8" = 1'-0"
3 G-12 KINESIO GROUP THERAPY
3/8" = 1'-0"
4 G-12 KINESIO GROUP THERAPY
0 1' 2' 4'6"
0 1' 2' 4'6"
0 1' 2' 4'6"
3/8" = 1'-0"
5 G-12 KINESIO GROUP THERAPY
0 1' 2' 4'6"
Revisions: Date:
SEAL 3/4" END DAM
RETURNS WITH SEALANT
INTERIOR PAN SILL
FLASHING
SLOPE TO OUTSIDE
NOTES:
• COORDINATE SILL PAN WITH WINDOW MANUFACTURER AND
DETAILS.
• SILL PAN FLASHING IS IN ADDITION TO MFR SUPPLIED HIGH
PERFORMANCE SILL FOR STOREFRONT INSTALLATION.
PROVIDE 2-SIDED "PEEL AND
STICK" MEMBRANE FLASHING
BETWEEN INTERIOR AND
EXTERIOR SILL FLASHING
COMPONENTS FOR THERMAL
BREAK
EXTERIOR SILL FLASHING
OUTSIDE
INSIDE
1" MIN
HIGH PERF. SILL MFR
COORD W/ STOREFRONT /
3/4"
LAP SEALANT
END DAMS FULL WIDTH TO
ROUGH OPENING &
SEALED TO WEATHER
RESISTIVE BARRIER (WRB)
R.O.
FLUID APPLIED WRB ON FACE OF
EXTERIOR SHEATHING AND CONTINUING
AROUND, UP AND OVER ON FACE OF
P.T. WOOD BLOCKING FOR
WIDTH/DEPTH INTO ROUGH OPENING
SEALANT
SEAL FASTENERS PER MFR
RECOMMENDATIONS.
PREFIN. ALUM. SUBSILL SET IN
CONTINUOUS SEALANT BED
1/8" FOAM GLAZING TAPE
SEE I.D. FINISHES FOR
MATERIAL AND FINISH OF
STOOL
CAULK
6"
PREFIN. ALUM. SILL PAN
FLASHING WITH 3/4" END DAMS,
3/4" BACK DAMS AND HEMMED
DRIP OVER METAL PANEL
GALV. 1 5/8" STEEL STUD WITH
TOP AND BOTTOM TRACK
GYPSUM BOARD, MOISTURE &
MOLD RESISTANT, TYPE 'X' (5/8")
CONCRETE FOOTING. REF.
STRUCTURAL
PREFIN. ALUMINUM
CURTAINWALL FRAME
PREFINISHED METAL SILL PAN
FLASHING WITH END DAMS AND
BACK DAM, SET IN CONT.
SEALANT. MAINTAIN 1:12 SLOPE
AT SILL MIN. PROVIDE 1 1/2" TURN
DOWN WITH HEMMED DRIP
INORGANIC SHIMS AS REQUIRED.
FILL VOIDS WITH NON-EXPANDING
CLOSED-CELL POLYURATHANE
SPRAY FOAM AND PROVIDE
BACKER ROD AND SEALANT BOTH
SIDES OF SHIMS
2" FOIL-FACED RIGID
POLYISO INSULATION WITH
GALV. "Z"-FURRING
CHANNELS (AND "J"
CHANNELS AT PERIMETER)
P.T. 2X WOOD
BLOCKING
GRADE LINE
4"
PRE-FINISHED
ALUMINUM AT GRADE
EXTENDED TO TOP OF
FOOTING
TO FACE OF FRAMING
1/2" FACE OF MULLION
SEALANT WITH BACKER
ROD
1/2"
1 1/8"
26" GA. S.S. FLASHING
6"2"
1 1/4"
FASTENERS 4" O.C. MAX.
ATTACHED TO METAL STUD /
BLOCKING
EXTERIOR INTERIOR
GYPSUM BOARD, MOISTURE &
MOLD RESISTANT, TYPE 'X' (5/8")
EXT. METAL GALV. FRAMING
STUD (6"), ENGINEERED, AT
16" O.C. MAX.
PREFIN. ALUMINUM
STOREFRONT FRAME
INORGANIC SHIMS AS
REQUIRED. FILL VOIDS
WITH NON-EXPANDING
CLOSED CELL SPRAY
FOAM AND PROVIDE
BACKER ROD AND
SEALANT BOTH SIDES
EXT. GLASS-MAT GYPSUM
SHEATHING (1/2")
SEAL FASTENERS PER
MFR RECOMMENDATIONS.
SEALANT
1/ 2"
2"
4 1/2"
FLUID APPLIED WRB ON
FACE OF EXT. GYP.
SHEATHING, CONTINUING
ONTO FACE OF METAL
STUD\ TO INTERIOR FACE
OF METAL STUD FRAMING
BRICK VENEER
PROVIDE DOUBLE
(UNPUNCHED) GALV. METAL
STUDS AT JAMB CONDITIONS
CAST STONE SILL
BELOW
5/8" GLASS-MAT GYP. BD.
RETURN AT JAMB
1" FACE OF MULLION
ADJUSTABLE HEIGHT
GALV. MASONRY VENEER
ANCHORS
FILL WITH NON-EXPANDING
CLOSED-CELL
POLYURETHANE SPRAY
FOAM INSULATION
2" FOIL-FACED RIGID
POLYISO INSULATION
WINDOW STOOL BELOW
GLASS-FIBER BLANKET
INSULATION (R-19); UNFACED
ALUM. HORIZONTAL
CURTAINWALL
MULLION
1" INSULATING GLASS
1/
2"
6"
EXTERIOR INTERIOR
1" INSULATING GLASS
6"6"
1/ 2"
6" 2 1/2"
SEALANT
SEA…
This is the start of the file's text. The full file is on GovTribe.