This document contains details of a federal solicitation for construction services. The solicitation number is 36C77622B0018 and is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation is for upgrades to the facilities electric and IT infrastructure at the Iron Mountain VA medical center to support a new Electronic Health Record Modernization system. The scope of work includes electrical upgrades, bonding, UPS installation, building management system interfaces, HVAC upgrades and expansions, communication infrastructure upgrades including new data outlets and Cat 6A cabling, physical security upgrades, and fiber optic infrastructure upgrades across the campus. The project involves reconfiguration and expansion of existing closet spaces.
View the file
Other files for this federal contract opportunity
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E
FACU
RELEASING PANEL
NAC
ZONE 2
ZONE 1
E
SQAF
A
KMAN. RELEASE
ABORT
KEY
DISABLE
14/4 14/2
NEW TELECOMM ROOM
RISER DIAGRAM
1/2" = 1'-0" BUILDING 11
120 VAC
DEDICATED
CIRCUIT
PANEL ALARM
ALARM
TROUBLE
SUPERVISORY
EXISTING LIFE
SAFETY SYSTEM
NEW TELECOMM ROOM
FIRE SUPRESSION SYSTEM
1/2" = 1'-0" BUILDING 11
FIRE ALARM DEVICE LEGEND
MANUFACTURERDESCRIPTIONMODELQTYSYMBOL
FIRE ALARM CONTROL PANEL
KEY DISABLE
1 MANUAL PULL STATION
1 ABORT PULL STATION
FACU
F A K
HORN/STROBE WALL MOUNT
2 PHOTOELECTRIC SMOKE DETECTOR
AEROSOL FIRE EXTINGUISHER AGENT LEGEND
MANUFACTURERDESCRIPTIONMODELQTYSYMBOL
FNX-12004 HOCHIKI
E
1200 AEROSOL GENERATOR, 1200 GRAMSHPS-DAK-SR
HCVR-AS
HCVR-3
SLK 835
SEQUENTIAL ACTIVATOR1SQA HCVR-SQA
HOCHIKI
HOCHIKI
HOCHIKI
HOCHIKI
HOCHIKI
FACU K
A
B
F
SQ
A
E E 120
EXTINGUISHANT
RELEASE 14/2
IDC 16/2
RED 10" BELL/WPF BBMBA-10241
NAC 14/2
RELAY / POWER SHUT DOWNA
NOTES
1. TIE TO EXISTING BUILDING FIRE ALARM SYSTEM, IF
BUILDING HAS ONE.
POTTER
E
E
SQ
A
E E
14/2
SQA
2ND FLOOR PLAN - BUILDING 11
1/8" = 1'-0"
NEW
TELECOMM
ROOM
NORTH
AREA OF WORK
A/E:
GDM OF OREGON
1584 McNeil St., Suite 200 Dupont, WA 98327 360-915-5128
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
VA FORM 08 - 6231
A
Program Contracting Activity
Central (PCAC)
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
REVISIONS: DATE:
LOCATION
04.20.202110% BASIS OF DESIGN STAMP
DRAWING TITLE
ISSUE DATE
100% CONSTRUCTION
DOCUMENTS
ELECTRONIC HEALTH RECORDS
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
585-21-700
35% SCHEMATIC DESIGN 06.01.2021
65% DESIGN DOCUMENTS 07.06.2021
10-29-2021OSCAR G. JOHNSON VA MEDICAL CENTER
325 E H ST.
IRON MOUNTAIN, MI 49801
95% DESIGN DOCUMENTS 08.09.2021
FOR OFFICIAL USE ONLY (FOUO)
100% CONSTRUCTION DOCUMENTS 10.29.2021
Northern Support Services, inc.
3911 Turnagain Blvd East Anchorage, Alaska 99517
(907) 952-4964
JAMES S. BLAIR
No. AELA 7725
10/29/2021
REG IS T ER ED P R O F E S S I O NA L A R CHIT ECT
NICET IV - 104143
BUILDING 11
TELECOMM ROOM
FIRE SUPPRESSION SYSTEM
011-FP-002
TERPconsulting -fire + life safety James P. Begley, PE, FSFPE, CFM Principal fire protection engineer
REVIEWED BY
ADDITION IS NOT SPRINKLERED
Low Pres. Tale
Tell Terminate Release
W/Dog Reset
Processor Reset
Exting.
Mon.
Write EnableExting. ReleaseModeMan.Rel.Abort
Trbl.Trbl.Trbl.Trbl.Trbl.Trbl.Trbl.
NAC3NAC1 NAC2Sys.FuseEarth
Trbl.Trbl.Trbl.Trbl.Trbl.
Comms
Low Batt.
Trbl.
Aux.24V
Trbl.
CPUFail
Batt.
Fail Mains
EXTRACT
SWITCH
REL PRES.
SWITCH
LOW P.EXTING.ABORT
RELEASE
MAN.
SELECT
MODE2ND STAGE1ST STAGENAC3POWERDATA
STATUS UNITS
REMOTE
CONTROL
AUX
24V
CNONOCNCNOCNC
ZONE 3ZONE 1 ZONE 2NAC2NAC1
RSTR0V SIL AL FLT NOCNCNOCNCNOCNC
FIRE RELAYLOCAL FIRETROUBLE RELAY
(+1)(+10) Enter System Mode Enable AccessSelectModeReset Lamp Test
(+100) Silence/Sound
Alarm
Power On
General System Status Fire In Zone
1 2 3
Zone Trouble/ On Test/ Disabled
Disablements/ Supervisory Releasing Status
Fire
Delay On
Test Mode On
General Disablement
NAC Trouble/ Disabled
Power Trouble
General Trouble
System Trouble
Buzzer Silenced
Manual Release
Extinguishant
1st Stage Output
2nd Stage Output
Extract Fan On
Release Imminent Auto &
Manual Manual
Only
Extinguishant Released
Low Pressue
1st Stage Activated
Abort Activated
Releasing Trouble
Silence Buzzer
Manual Extinguishant Release
Pull Down - Push Button
HCVR-3 EXTINGUISHANT PANEL CONNECTIONS
N.T.S.
TO KEY DISABLE / SEQUENTIAL ACTUATORS
TO ABORT STATIONS
TROUBLE, ALARM TO
EXISTING FIRE ALARM PANEL
TO MANUAL RELEASE STATIONS
MR204
DEDICATED 120 VAC
NAC 2 TO INTERIOR
HORN/ STROBES
IDC ZONE 1 TO SMOKE
DETECTORS 'A'
IDC ZONE 3 TO MANUAL
PULL STATION
TO KEY DISABLE / SEQUENTIAL ACTUATORS
IDC ZONE 2 TO SMOKE
DETECTORS 'B'
A/E:
GDM OF OREGON
1584 McNeil St., Suite 200 Dupont, WA 98327 360-915-5128
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
VA FORM 08 - 6231
A
Program Contracting Activity
Central (PCAC)
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
REVISIONS: DATE:
LOCATION
04.20.202110% BASIS OF DESIGN STAMP
DRAWING TITLE
ISSUE DATE
100% CONSTRUCTION
DOCUMENTS
ELECTRONIC HEALTH RECORDS
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
585-21-700
35% SCHEMATIC DESIGN 06.01.2021
65% DESIGN DOCUMENTS 07.06.2021
10-29-2021OSCAR G. JOHNSON VA MEDICAL CENTER
325 E H ST.
IRON MOUNTAIN, MI 49801
95% DESIGN DOCUMENTS 08.09.2021
FOR OFFICIAL USE ONLY (FOUO)
100% CONSTRUCTION DOCUMENTS 10.29.2021
Northern Support Services, inc.
3911 Turnagain Blvd East Anchorage, Alaska 99517
(907) 952-4964
JAMES S. BLAIR
No. AELA 7725
10/29/2021
REG IS T ER ED P R O F E S S I O NA L A R CHIT ECT
NICET IV - 104143
EXTINGUISHANT
PANEL CONNECTIONS
000-FP-005
TERPconsulting -fire + life safety James P. Begley, PE, FSFPE, CFM Principal fire protection engineer
A/E:
GDM OF OREGON
1584 McNeil St., Suite 200 Dupont, WA 98327 360-915-5128
PROJECT NO.
BUILDING NO.
DRAWING NO.
PROJECT TITLE
FLS
CHECKED BY DRAWN BY
APPROVED: PROJECT DIRECTOR
VA FORM 08 - 6231
A
Program Contracting Activity
Central (PCAC)
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHASE
ARCHITECT/ENGINEER OF RECORDCONSULTANT
321 4 5 6 7 8 9 10
REVISIONS: DATE:
LOCATION
04.20.202110% BASIS OF DESIGN STAMP
DRAWING TITLE
ISSUE DATE
100% CONSTRUCTION
DOCUMENTS
ELECTRONIC HEALTH RECORDS
MODERNIZATION (EHRM)
INFRASTRUCTURE UPGRADES
585-21-700
35% SCHEMATIC DESIGN 06.01.2021
65% DESIGN DOCUMENTS 07.06.2021
10-29-2021OSCAR G. JOHNSON VA MEDICAL CENTER
325 E H ST.
IRON MOUNTAIN, MI 49801
95% DESIGN DOCUMENTS 08.09.2021
FOR OFFICIAL USE ONLY (FOUO)
100% CONSTRUCTION DOCUMENTS 10.29.2021
Northern Support Services, inc.
3911 Turnagain Blvd East Anchorage, Alaska 99517
(907) 952-4964
JAMES S. BLAIR
No. AELA 7725
10/29/2021
REG IS T ER ED P R O F E S S I O NA L A R CHIT ECT
NICET IV - 104143
DESIGN GUILDLINES
000-FP-006
TERPconsulting -fire + life safety James P. Begley, PE, FSFPE, CFM Principal fire protection engineer