EHRM Asbestos Report.pdf

PDF 11 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction - Iron Mountain Federal contract opportunity
Solicitation number
36C77622B0018
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document contains details of a federal contract opportunity for infrastructure upgrades at the Iron Mountain VA Medical Center. The Department of Veterans Affairs Technology Acquisition Center Austin is soliciting proposals for a project to upgrade the electric, IT, HVAC, communication, security, and fiber optic infrastructure at various buildings to support a new Electronic Health Record Modernization system. The scope of work includes electrical upgrades, bonding, uninterruptible power supply systems, building management system interfaces, closet space reconfigurations and expansions, upgraded data and fiber optic cabling, and physical security improvements across the campus. The opportunity number is 36C77622B0018 and proposals are due by the date specified in the solicitation.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction - Iron Mountain, newest first.
File Type Posted
36C77622B0018 0003.pdf PDF
09 69 00 Access Flooring-Addenda 2.pdf PDF
Technical Questions - FINAL - Iron Mtn. 6-27-22.pdf PDF
Addendum 1.pdf PDF
ATTACHMENT 17 - Construction Wage Rates - Dickinson 6-17-22.pdf PDF
36C77622B0018 0002.pdf PDF
Site Visit Sign-in Sheet - Iron Mtn. 5-18-22.pdf PDF
36C77622B0018 0001.pdf PDF
ATTACHMENT 2 - Specifications VOL 2 of 2.pdf PDF
ATTACHMENT 3 - Drawings VOL 1 - 1 of 5.pdf PDF
ATTACHMENT 15 - COVID-19 Safety Protocols 12-14-21.pdf PDF
ATTACHMENT 19 - Site Visit Instructions.pdf PDF
ATTACHMENT 1 - Specifications VOL 1 of 2.pdf PDF
ATTACHMENT 13 - Drawings VOL 2 - 6 of 7.pdf PDF
ATTACHMENT 17 - Construction Wage Rates - Dickinson 2-25-22.pdf PDF
ATTACHMENT 8 - Drawings VOL 2 - 1 of 7.pdf PDF
ATTACHMENT 9 - Drawings VOL 2 - 2 of 7.pdf PDF
ATTACHMENT 12 - Drawings VOL 2 - 5 of 7.pdf PDF
ATTACHMENT 14 - Drawings VOL 2 - 7 of 7.pdf PDF
36C77622B0018 - 5-5-22.pdf PDF
ATTACHMENT 4 - Drawings VOL 1 - 2 of 5.pdf PDF
ATTACHMENT 5 - Drawings VOL 1 - 3 of 5.pdf PDF
ATTACHMENT 6 - Drawings VOL 1 - 4 of 5.pdf PDF
ATTACHMENT 7 - Drawings VOL 1 - 5 of 5.pdf PDF
ATTACHMENT 10 - Drawings VOL 2 - 3 of 7.pdf PDF
ATTACHMENT 11 - Drawings VOL 2 - 4 of 7.pdf PDF
ATTACHMENT 16 - Limitations on Subcontracting - Construction.docx DOCX document
ATTACHMENT 18 - Contractor Safety - Environmental Form.docx DOCX document
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Manual for: Building 1

Oscar G. Johnson VA Medical Center Iron Mountain, Michigan

Asbestos Management Plan VA Project 585-14-111

February 2015

100% Documents

NDW Project Number:

BDN Project Number:

16297

Compiled By: Prepared By:

420 Rail Street 8105 Valleywood Lane Negaunee, MI 49866 Portage, MI 49024 906-475-6616 269-329-1237

WWW.NDW.US

http://www.ndw.us/

TABLE OF CONTENTS

INTRODUCTION

SCOPE OF WORK

BUILDING DESCRIPTION

METHODOLOGY

ASBESTOS SURVEY

SAMPLE ANALYSIS

ASBESTOS SURVEY RESULTS

HAZARD RANKING

POTENTIAL FOR DISTURBANCE

CONCLUSIONS AND RECOMMENDATIONS

APPENDICES

APPENDIX A: Functional Space, Material Description, Asbestos Analytical Result

Summary

– Sorted by Space

– Sorted by Material

APPENDIX B: Analytical Report

APPENDIX C: Photographs

APPENDIX D: Floor Plans

APPENDIX E: Operations and Maintenance Plan

APPENDIX F: Asbestos Abatement Estimates

INTRODUCTION

Northern Design Works of Negaunee, MI, retained BDN Industrial Hygiene Consultants, Inc. to conduct a building inspection to determine the presence, quantities, and locations of asbestos-containing building materials (ACBM) in Building 1 at the Oscar G. Johnson VA Medical Center, Iron Mountain, Michigan.

Scope of Work The scope of work BDN performed in Building 1 consisted of a complete survey of the sub-basement. A full survey was performed of the basement, not including east of the engineering suite and CLC area. The 1st floor included complete surveys of rooms: 1214, 1216, 1243, 1284, 1288, 1288A, 1294, 1286A, and 1286. The pharmacy area was surveyed for steam and condensate piping only. A full survey was performed on the 2nd floor, mechanical room 2180. Vertical steam and condensate piping was located in chases on the 3rd floor and also a full survey of rooms: 3142A, 3142, 3160, 3143, and the canteen suite. 4th floor vertical steam and condensate piping was located along with a full survey of rooms: 4142A, 4142, and 4143. A complete survey was conducted on the 5th floor.

BDN identified building materials suspected of containing asbestos in Building 1. These materials were surveyed in a manner compliant with the sampling protocols of the Asbestos Hazard Emergency Response Act (AHERA) by inspecting the materials for damage, measuring the amount of material and obtaining sample(s) for laboratory analysis. The survey was completed by BDN industrial hygienists Travis Noa, asbestos inspector accreditation number A38262 and David Steger, asbestos inspector accreditation number A1788, both are Michigan-accredited asbestos building inspectors.

This Asbestos Survey was conducted to identify the types, quantities, locations, and conditions of the asbestos-containing materials within Building 1.

Building Description Building 1 of the Oscar G. Johnson VA Medical Center is located at 325 East H Street, Iron Mountain, Michigan. Building 1 is an eight story building with basement and sub-basement. The exterior of Building 1 is brick with a flat roof. The interior of Building 1 has wood-framed, concrete block, and metal-framed walls covered with plaster and drywall.

The floors are a mix of hardwood, linoleum, carpet, ceramic tile, floor tile and concrete.

The ceilings consisted of drop ceilings, ceiling tile, plaster, and concrete. The total square footage for Building 1 is approximately 269,749 square feet.

METHODOLOGY

Asbestos Survey BDN industrial hygienists Travis Noa, asbestos inspector accreditation number A38262 and David Steger, asbestos inspector accreditation number A1788 conducted the asbestos survey of Building 1 in November and December of 2014, and January of 2015.

Field inspection alone is not conclusive to identify asbestos-containing materials.

Therefore, bulk samples of suspected asbestos-containing materials (ACMs) were obtained using U.S. EPA/OSHA protocols by a State-accredited inspector and analyzed to determine if asbestos fibers were present, and if found, the types and percentages of asbestos were reported.

BDN recommends that when suspect ACMs not identified within the report are encountered for which no analytical data exists, the materials remain undisturbed until the asbestos content of the materials(s) is determined in accordance with U.S. EPA and OSHA regulations. BDN’s quantities are intended to be “Order of Magnitude” estimates and the estimated quantities and other information in this report should not be used as an exclusive source of information for bid formulation or for notification to regulatory agencies.

Bulk samples of friable suspected ACMs were obtained using U.S. EPA/OSHA protocols by a State of Michigan accredited inspectors. An area the approximate size of a half-dollar was thoroughly wetted with water and a wetting agent applied from a handheld spray bottle to reduce fiber release during sample collection. A knife or boring tool was used to cut the outer protective covering to expose the suspected ACM underneath. The knife or boring tool was then employed to remove a small amount of the material for the sample. Bulk samples of non-friable suspected ACMs were collected using hand tools to obtain a sample approximately the size of a postage stamp. The sample was placed in a resealable plastic bag, labeled, and secured. Wood and Metal fire-rated doors are assumed to be asbestos-containing due to the damaging effects to obtain samples which would compromise the fire rating of the door. BDN followed U.S. EPA and OSHA protocols for determining sampling locations and total number of samples taken.

Sample Analysis

Laboratory descriptions of materials analyzed by Polarized Light Microscopy (PLM) method for asbestos content were based upon the microscopist’s perceptions of bulk samples that were pulverized and prepared with dispersion oils for PLM analysis. Due to the preparation of the sampled materials and the minute level of observation by the laboratory personnel, the descriptions on the Certificates of Analysis may not match the sample descriptions recorded by BDN in the field. BDN’s sample descriptions and locations should be used to identify materials that were sampled and BDN’s sample numbers should be used to correlate analytical results for the sampled materials.

Building material samples collected from Building 1 at the Oscar G. Johnson VA Medical Center were submitted to the asbestos laboratory at BDN in Portage, Michigan.

Laboratory descriptions of materials analyzed by Polarized Light Microscopy (PLM) method for asbestos content were based upon the microscopists’ visual observations of bulk samples that were homogenized and prepared for analysis. The analytical data from the asbestos-containing materials is presented in the tables below.

ASBESTOS SURVEY RESULTS

As detailed in the tables below, the following materials were identified as asbestos-containing material:

Sub-Basement

DESCRIPTION OF ASBESTOS

CONTAINING MATERIAL

LOCATION QUANTITY

Pipe Wrap - Black Sub-Basement 24 ln.ft.

Metal Fire Rated Doors Sub-Basement 4 doors

Basement

DESCRIPTION OF ASBESTOS

CONTAINING MATERIAL

LOCATION QUANTITY

Paper Pipe Insulation (Aircell)

Basement 1511 sq. ft.

Pipe Wrap - Black

Basement 214 sq. ft.

Floor Tile - 9"x9" Green with White Streaks and Adhesive

Basement 24 sq. ft.

Floor Tile - 12" x 12" - Light Yellow with Gold Flakes with Mastic

Basement 800 sq. ft.

Floor Tile - 12"x12" - Light Brown with Brown Streaks with Mastic

Basement 126 sq. ft.

Floor Tile - 12"x12" - Light Grey with

Basement 751 sq. ft.

Metal Fire Door with Fire Tag

Basement 48 doors

Wood Fire Doors with Fire Tag

Basement 13 doors

1st Floor

Floor Tile - 12"x12" - White with Tan Streaks with Mastic

1st Floor 988 sq. ft.

1st Floor 284 ln. ft.

2nd Floor

Duct Insulation - White

2nd Floor 2 sq. ft.

2nd Floor 6 doors

3rd Floor

Floor Tile - 9"x9" - Red with Tan and White Flakes with Mastic

3rd Floor 48 sq. ft.

Mudded Fitting - 3rd Floor

3rd Floor 2 fittings

3rd Floor 638 ln. ft.

3rd Floor 10 ln. ft.

3rd Floor 2 doors

4th Floor

4th Floor 538 ln. ft.

4th Floor 1 door

5th Floor

Floor Tile - 12"x12" - Light Brown with

5th Floor 320 sq. ft.

Floor Tile - 12"x12" - Light Grey with

5th Floor 992 sq. ft.

Floor Tile - 12"x12" - White with Tan Streaks with Mastic

5th Floor 680 sq. ft.

Floor Tile - 9"x9" - Red with Tan and White Flakes with Mastic

5th Floor 126 sq. ft.

Mag Pipe Insulation

5th Floor 8 ln. ft.

Metal Fire Door with Fire Tag

5th Floor 11 doors

5th Floor 547 ln. ft.

5th Floor 12 ln. ft.

5th Floor 13 doors

A summary of the functional space names, descriptions of materials, observed quantities, hazard rankings, and analytical results are presented in Appendix A. The laboratory analytical report is presented as Appendix B. Photos of these materials are provided in Appendix C. Asbestos was not detected in the other sampled materials.

HAZARD RANKINGS

DEPARTMENT OF VETERANS AFFAIRS VA MEDICAL CENTER

IRON MOUNTAIN, MICHIGAN

Hazard Rank Removal Priority AHERA Categories Response Action Required by

AHERA

1 1 Significantly Damaged Evacuate or isolate the area if needed.

Remove the ACBM (or enclose or encapsulate if sufficient to contain fibers).

Repair of thermal system insulation is allowed if feasible and safe. O&M required for all friable ACBM.

2 2 Damaged + Potential for Significant Damage

Evacuate or isolate the area if needed.

Remove, enclose, encapsulate, or repair to correct damage. Take steps to reduce potential for disturbance. O&M required for all friable ACBM.

3 3 Damaged + Potential for Damaged

Remove, enclose, encapsulate, or repair to correct damage. O&M required for all friable ACBM.

4 4 Damaged Same as hazard rank 5.

5 5 Potential for Significant Damage

Evacuate or isolate the area if needed.

Take steps to reduce potential for disturbance. O&M required for all friable ACBM and TSI.

6 6 Potential for Damage O&M required for all friable ACBM and

TSI.

7 7 All Remaining ACBM O&M required for all friable ACBM, but measures need not be as extensive as above.

NOTE: AHERA DOES NOT ACCOUNT FOR COMBINATIONS OF CURRENT AND

POTENTIAL DAMAGE (I.E., HAZARD RANKS #5 AND 6). THE RESPONSE ACTIONS

SHOWN ARE COMBINATIONS OF THOSE REQUIRED FOR EACH CONDITION.

Potential for Disturbance

Asbestos-containing materials are rated for Potential for Disturbance. The ratings are located on the spreadsheet. The ratings are as follows:

L = Low, no direct contact with employees, patients, and/or visitors M = Medium, minimal contact with employees only H = High, direct contact by employees, patients, and or visitors

CONCLUSIONS AND RECOMMENDATIONS

General Materials BDN identified asbestos-containing materials and recommends that these materials be removed by a licensed asbestos abatement contractor prior to renovation or demolition activities that would disturb this material in any way. Personal and clearance air samples should be collected to demonstrate that asbestos fibers are not released through the abatement process.

Notification

A “Notification of Intent to Renovate/ Demolish” form required by the U.S. EPA NESHAP regulations must be submitted to the MDEQ-AQD 10-working days prior to removal of the asbestos quantities of 260 lineal feet, 160 square feet or 35 cubic feet.

Regulatory Information Regarding Asbestos Removal, Renovation, and Demolition

A licensed asbestos removal contractor, utilizing workers accredited under the requirements of Michigan, must perform asbestos removal work. BDN recommends asbestos abatement project design by a Project Designer accredited under the requirements of Michigan Act 440 and monitoring asbestos removal work with air sampling, visual verification and clearance air monitoring performed by an independent third party. All ACM waste generated should be placed in doubled, labeled waste bags, affixed with a waste generator location label and disposed in a Type II landfill. All ACM waste removed from the site should be inventoried on a Waste Shipment Record that complies with NESHAP regulations, 40 CFR Part 61.

Once an asbestos building survey has confirmed or assumed the presence of ACMs, all employees who work around and may contact, but not disturb ACMs (i.e., persons conducting janitorial, building maintenance, security and/or housekeeping activities) must receive, at minimum, two-hour asbestos awareness training. Additionally, employees who may disturb ACMs (i.e., persons working with any of the mechanical systems that have asbestos-containing materials) must have additional asbestos-related training that satisfies the class of work activity that they are involved with (i.e., Class I, II or III).

Before allowing a contractor to work on their building, building owners should also ascertain if the contractor has acquired asbestos awareness training. Such training is required when the contractor works in the proximity of ACMs and may contact, but not disturb the material.

Building owners removing asbestos-containing materials from their own structure are not required to be a Michigan-licensed asbestos abatement contractor, however, the building owner’s employees performing the work must comply with the requirements of Part 602, the MIOSHA Asbestos Standards for Construction and hold a current Contractor/Supervisor card. No notifications are required for properly trained employees removing ACM in the employer owned facility.

ASBESTOS MANAGEMENT PLAN

Oscar G. Johnson VA Medical Center

325 East H Street

Iron Mountain, MI

APPENDIX A

Functional Space Summary

Sorted by Space

Sorted by Material

BDN JOB NO. 16297

NDW NO. 1416

Sorted by Floor and Space Name VA Medical Center

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 1 204 Room 1213 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 1 93 Room 1214 Base Trim - 4" - Light Grey sq. ft. --- --- --- Negative --- --- None --- 1 1 93 Room 1214 Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 1 93 Room 1214 Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 108 sq. ft. --- --- --- Negative --- --- None --- 1 1 93 Room 1214 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 1 93 Room 1214 Floor Tile - 12"x12" - White with 108 sq. ft. --- --- --- Tile - Positive 6 H O & M ---

1 1 93 Room 1214 Paper Pipe Insulation (Aircell) 20 ln. ft. --- --- --- Positive 7 L O & M down dumb waiter, assumed

1 1 93 Room 1214 Plaster Walls and Ceilings 420 sq. ft. --- --- --- Negative --- --- None --- 1 1 93 Room 1214 Wood Doors - No Fire Tags 1 door (s) --- --- --- --- --- --- None --- 1 1 203 Room 1215 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 1 202 Room 1217 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 1 211 Room 1224

Hallway Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M

North end of hallway, line in coat room removed

1 1 206 Room 1228 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M NE corner chase, assumed

1 1 201 Room 1229 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- --- 1 1 201 Room 1229 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NW Chase 1 1 210 Room 1233A Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SW corner chase

1 1 205 Room 1234 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SW corner chase, not on floor plan print

1 1 207 Room 1236 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 1 209 Room 1237 Paper Pipe Insulation (Aircell) 24 ln. ft. --- --- --- Positive 7 L O & M NW and SW corner chases

1 1 208 Room 1238 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NE corner chase

1 1 92 Room 1284

Chapel Base Trim - 6" - Brown 110 sq. ft. --- --- --- Negative --- --- None ---

1 1 92 Room 1284

Chapel Carpet --- --- --- --- --- --- --- --- None ---

1 1 92 Room 1284

Chapel Ceiling Tile - 1'x1' - Fiberglass -

White with Grey Specks --- --- --- --- --- --- --- --- None ---

1 1 92 Room 1284

Chapel Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 48 sq. ft. --- --- --- Negative --- --- None ---

1 1 92 Room 1284

Chapel Drywall 180 sq. ft. --- --- 16297-1-18.3 None

Detected --- --- None ---

1 1 92 Room 1284

Chapel Drywall Joint Compound 180 sq. ft. --- --- 16297-1-19.3 None

Detected --- --- None ---

1 1 92 Room 1284

Chapel Floor Tile - 12"x12" - White with

Tan Streaks with Mastic 684 sq. ft. --- --- ---

Tile - Positive Mastic - Negative 6 H O & M under carpet

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 1 92 Room 1284

Chapel Paper Pipe Insulation (Aircell) 94 ln. ft. --- --- --- Positive 7 L O & M

(2) vertical lines in South center chase (2) vertical lines SE chase

(1) vertical 18" line along south wall (1) vertical 36" line along south wall above ceiling tile

1 1 92 Room 1284

Chapel Plaster Walls and Ceilings 1,100 sq. ft. --- --- 16297-1-3.5 None

Detected --- --- None ---

1 1 92 Room 1284

Chapel Wood Doors - No Fire Tags 4 door (s) --- --- --- --- --- --- None --- 1 1 94 Room 1294 Base Trim - 4" - Tan 118 sq. ft. --- --- --- Negative --- --- None --- 1 1 94 Room 1294 Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 1 94 Room 1294 Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 572 sq. ft. --- --- --- Negative --- --- None --- 1 1 94 Room 1294 Drywall 1,360 sq. ft. --- --- --- Negative --- --- None --- 1 1 94 Room 1294 Drywall Joint Compound 1,360 sq. ft. --- --- --- Negative --- --- None --- 1 1 94 Room 1294 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 1 94 Room 1294 Floor Tile - 12"x12" - Pink with Light Pink Flakes with Mastic 572 sq. ft. --- --- ---

Tile and Mastic

Negative --- --- None ---

1 1 94 Room 1294 Paper Pipe Insulation (Aircell) 60 ln. ft. --- --- --- Positive 7 L O & M

(2) vertical lines in NE chase (2) vertical lines in N center chase (2) vertical lines in center chase

1 1 94 Room 1294 Wood Doors - No Fire Tags 1 door (s) --- --- --- --- --- --- None ---

1 1 91 Rooms 1286 &

1286A Base Trim - 6" - Grey 60 sq. ft. --- --- --- Negative --- --- None ---

1 1 91 Rooms 1286 &

1286A Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 1 91 Rooms 1286 &

1286A Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 180 sq. ft. --- --- --- Negative --- --- None ---

1 1 91 Rooms 1286 &

1286A Drywall 100 sq. ft. --- --- --- Negative --- --- None ---

1 1 91 Rooms 1286 &

1286A Drywall Joint Compound 100 sq. ft. --- --- --- Negative --- --- None ---

1 1 91 Rooms 1286 &

1286A Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 1 91 Rooms 1286 &

1286A Floor Tile - 12"x12" - Tan with

White Flakes with Mastic 180 sq. ft. --- --- 16297-1-55.1

Tile and Mastice None

Detected --- --- None ---

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 1 91 Rooms 1286 &

1286A Paper Pipe Insulation (Aircell) 10 ln. ft. --- --- --- Positive 7 L O & M

(1) vertical line in SW corner 1286A

1 1 91 Rooms 1286 &

1286A Plaster Walls and Ceilings 460 sq. ft. --- --- --- Negative --- --- None ---

1 1 91 Rooms 1286 &

1286A Wood Doors - No Fire Tags 2 door (s) --- --- --- --- --- --- None ---

1 1 90 Rooms 1288 &

1288A Base Trim - 6" - Black 55 sq. ft. --- --- --- Negative --- --- None ---

1 1 90 Rooms 1288 &

1288A Base Trim - 6" - Brown 40 sq. ft. --- --- --- Negative --- --- None

(2) vertical lines in NE chase of 1288. (2) vertical lines in 1288A, south wall.

1 1 90 Rooms 1288 &

1288A Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 1 90 Rooms 1288 &

1288A Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 1 90 Rooms 1288 &

1288A Floor Tile - 12"x12" - White with

Grey Flakes with Mastic 48 sq. ft. --- --- 16297-1-54.1

Tile and Mastic none detected --- --- None ---

1 1 90 Rooms 1288 &

1288A Floor Tile - 12"x12" - White with

Tan Streaks with Mastic 196 sq. ft. --- --- ---

Tile - Positive Mastic - Negative 6 H O & M ---

1 1 90 Rooms 1288 &

1288A Paper Pipe Insulation (Aircell) 20 ln. ft. --- --- --- Positive 7 L O & M ---

1 1 90 Rooms 1288 &

1288A Plaster Walls and Ceilings 680 sq. ft. --- --- --- Negative --- --- None ---

1 2 91.1 Room 2180

Mechnical room Brick Walls --- --- --- --- --- --- --- --- None ---

1 2 91.1 Room 2180

Mechnical room Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 2 91.1 Room 2180

Mechnical room Concrete Slab Floor --- --- --- --- --- --- --- --- None ---

1 2 91.1 Room 2180

Mechnical room Duct Insulation - White 2 sq. ft. --- --- 16297-1-50.1 35%

Chrysotile 6 M O & M SE Corner

1 2 91.1 Room 2180

Mechnical room Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 2 91.1 Room 2180

Mechnical room Vinyl Vibration Dampener 5 sq. ft. --- --- --- --- --- --- None ---

1 2 91.1 Room 2180

Mechnical room White Fibrous Pipe Insulation 12 sq. ft. --- --- 16297-1-51.1 16297-1-51.2

None Detected

None Detected --- --- None

(1) horizontal line close to ground, center of south wall

1 2 91.1 Room 2180

Mechnical room Wood Fire Doors with Fire Tag 6 door (s) --- --- Assumed Assumed 7 L O & M ---

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 3 319

Mechanical Shaft near service elevator Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- ---

1 3 261 NE Mechanical

Shaft Pipe Wrap - Black 10 ln. ft. --- --- 16297-1-29.4 30%

Chrysotile 6 M O & M SW corner

1 3 307 NW Mechanical

Shaft Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 276 Room 3105 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 277 Room 3109 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 278 Room 3113 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 284 Room 3116 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M NE and SE wall chases 1 3 279 Room 3117 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NW corner chase 1 3 285 Room 3118 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SW corner chase 1 3 318 Room 3127 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M

1 3 308 Room 3128 Paper Pipe Insulation (Aircell) 16 ln. ft. --- Positive 7 L O & M NW and SW corner chases

1 3 317 Room 3129 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M 1 3 316 Room 3131 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SE corner chase 1 3 309 Room 3132 Paper Pipe Insulation (Aircell) 8 ln. ft. 1 ln. ft. Positive 3 L O & M SW corner chase 1 3 315 Room 3133 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NE corner chase 1 3 310 Room 3134 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NW corner chase 1 3 314 Room 3135 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SE corner chase 1 3 311 Room 3136 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SW corner chase

1 3 313 Room 3137 Paper Pipe Insulation (Aircell) 24 ln. ft. --- --- --- Positive 7 L O & M NW, NE, and center chases

1 3 312 Room 3138 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NW corner chase 1 3 88 Room 3143 Ceramic Tile --- --- --- --- --- --- --- --- None --- 1 3 88 Room 3143 Drywall Drop Ceiling Tiles 56 sq. ft. --- --- --- Negative --- --- None ---

1 3 88 Room 3143 Paper Pipe Insulation (Aircell) 10 ln. ft. --- --- --- Positive 7 L O & M

(1) vertical line in NE corner next to laundry chute

1 3 88 Room 3143 Plaster Walls and Ceilings 300 sq. ft. --- --- 16297-1-3.4 None

Detected --- --- None ---

1 3 88 Room 3143 Wood Fire Doors with Fire Tag 1 door (s) --- --- Assumed Assumed 7 L O & M --- 1 3 306 Room 3145 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NE corner chase

1 3 300 Room 3146 Paper Pipe Insulation (Aircell) 0 ln. ft. --- --- --- --- --- --- None Lines have been removed

1 3 305 Room 3147 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M NW corner chase

1 3 301 Room 3148 Paper Pipe Insulation (Aircell) 24 ln. ft. --- --- --- Positive 7 L O & M NE and SE corner chases

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 3 304 Room 3149 Paper Pipe Insulation (Aircell) 0 ln. ft. --- --- --- --- --- --- None Lines located in Room

1 3 302 Room 3150 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M

1 3 303 Room 3151 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M SW and NW corner chases

1 3 320 Room 3160 Ceramic Tile --- --- --- --- --- --- --- --- None --- 1 3 320 Room 3160 Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 3 320 Room 3160 Drywall 260 sq. ft. --- --- 16297-1-18.2 None

Detected --- --- None --- 1 3 320 Room 3160 Drywall Drop Ceiling Tiles 42 sq. ft. --- --- --- Negative --- --- None ---

1 3 320 Room 3160 Drywall Joint Compound 260 sq. ft. --- --- 16297-1-19.2 None

Detected --- --- None --- 1 3 320 Room 3160 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 320 Room 3160 Wood Doors - No Fire Tags 1 door (s) --- --- --- --- --- --- None --- 1 3 299 Room 3162 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M West chase

1 3 286 Room 3167 &

3165 Paper Pipe Insulation (Aircell) 32 ln. ft. --- --- --- Positive 7 L O & M

(2) lines in mens room

(2) lines in womens room

1 3 297 Room 3168 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NW corner chase 1 3 287 Room 3169 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NE corner chase 1 3 296 Room 3170 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SW corner chase 1 3 288 Room 3171 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SE corner chase 1 3 295 Room 3172 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NW corner chase 1 3 289 Room 3173 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NE corner chase 1 3 294 Room 3174 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SW corner chase 1 3 290 Room 3175 Paper Pipe Insulation (Aircell) 6 ln. ft. --- --- --- Positive 7 L O & M SW corner chase 1 3 291 Room 3177 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NE corner chase 1 3 293 Room 3178 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SW corner chase

1 3 292 Room 3179 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M SE corner chase and south wall chase

1 3 281 Room 3184A Paper Pipe Insulation (Aircell) 0 ln. ft. --- --- --- --- --- --- None Lines have been removed

1 3 282 Room 3184B Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SW corner chase

1 3 283 Room 3184C Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M SE and SW wall chases 1 3 275 Room 3209 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 274 Room 3211 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 219 Room 3222 Ceramic Tile --- --- --- --- --- --- --- --- None --- 1 3 219 Room 3222 Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 3 219 Room 3222 Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 54 sq. ft. --- --- --- Negative --- --- None --- 1 3 219 Room 3222 Plaster Walls and Ceilings 300 sq. ft. --- --- --- Negative --- --- None --- 1 3 219 Room 3222 Wood Doors - No Fire Tags 1 door (s) --- --- --- --- --- --- None ---

1 3 272 Room 3225 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None Chases along North wall

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 3 268 Room 3227 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 273 Room 3228 Paper Pipe Insulation (Aircell) 24 ln. ft. --- --- --- Positive 7 L O & M Stairwell wall chases 1 3 266 Room 3229 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 267 Room 3229 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 269 Room 3230 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 270 Room 3232 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 265 Room 3233 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 271 Room 3234 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 263 Room 3235 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 264 Room 3238 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 260 Room 3243 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M Line in chute

1 3 262 Room 3244 Paper Pipe Insulation (Aircell) 0 ln. ft. --- --- --- --- --- --- None Lines have been removed

1 3 257 Room 3245 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 258 Room 3246 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 259 Room 3248 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 256 Room 3249 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 3 255 Room 3250 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 3 215 Room 3261 Base Trim - 6" - Green 45 sq. ft. --- --- 16297-1-75.1 None

Detected --- --- None --- 1 3 215 Room 3261 Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 3 215 Room 3261 Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 1,344 sq. ft. --- --- --- Negative --- --- None --- 1 3 215 Room 3261 Drywall Drop Ceiling Tiles 1,344 sq. ft. --- --- --- --- --- --- None ---

1 3 215 Room 3261 Floor Tile - 12"x12" - Cream with Grey Flakes with Mastic 2,268 sq. ft. --- --- --- Negative --- --- None ---

1 3 215 Room 3261 Paper Pipe Insulation (Aircell) 88 ln. ft. --- --- --- Positive 7 L O & M

(11) lines in exterior wall chases

1 3 216 Room 3262 Carpet --- --- --- --- --- --- --- --- None --- 1 3 216 Room 3262 Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 3 216 Room 3262 Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 768 sq. ft. --- --- --- Negative --- --- None --- 1 3 216 Room 3262 Drywall 1,200 sq. ft. --- --- --- Negative --- --- None --- 1 3 216 Room 3262 Drywall Joint Compound 1,200 sq. ft. --- --- --- Negative --- --- None ---

1 3 216 Room 3262

Floor Tile - 9"x9" - Red with Tan and White Flakes with

Mastic 48 sq. ft. --- --- --- Positive 6 H O & M Storage room 3260 1 3 216 Room 3262 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M Center chase 1 3 216 Room 3262 Wood Doors - No Fire Tags 1 door (s) --- --- --- --- --- --- None --- 1 3 214 Room 3267 Ceramic Tile --- --- --- --- --- --- --- --- None --- 1 3 214 Room 3267 Drywall Drop Ceiling Tiles 672 sq. ft. --- --- --- --- --- --- None ---

1 3 214 Room 3267 Paper Pipe Insulation (Aircell) 32 ln. ft. --- --- --- Positive 7 L O & M North center wall, (4) lines in chase

1 3 214 Room 3267 Wood Doors - No Fire Tags 3 door (s) --- --- --- --- --- --- None --- 1 3 217 Room 3272 Carpet --- --- --- --- --- --- --- --- None ---

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 3 217 Room 3272 Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 99 sq. ft. --- --- --- Negative --- --- None ---

1 3 217 Room 3272 Floor Tile - 12"x12" - Cream with Grey Flakes with Mastic 99 sq. ft. --- --- --- Negative --- --- None Under carpet

1 3 217 Room 3272 Plaster Walls and Ceilings 316 sq. ft. --- --- --- Negative --- --- None --- 1 3 217 Room 3272 Wood Doors - No Fire Tags 1 door (s) --- --- --- --- --- --- None --- 1 3 218 Room 3274 Concrete Block Wall --- --- --- --- --- --- --- --- None --- 1 3 218 Room 3274 Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 3 218 Room 3274 Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 176 sq. ft. --- --- --- Negative --- --- None ---

1 3 218 Room 3274 Floor Tile - 12"x12" - Cream with Grey Flakes with Mastic 176 sq. ft. --- --- --- Negative --- --- None ---

1 3 218 Room 3274 Paper Pipe Insulation (Aircell) 24 ln. ft. --- --- --- Positive 7 L O & M Assumed in exterior wall chases

1 3 280 Room 3280 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M South wall chase 1 3 212 Room 3286 Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 3 212 Room 3286 Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 200 sq. ft. --- --- --- Negative --- --- None ---

1 3 212 Room 3286 Floor Tile - 12"x12" - White with

Grey Flakes with Mastic 200 sq. ft. --- --- --- Negative --- --- None --- 1 3 212 Room 3286 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M Exterior wall chase 1 3 212 Room 3286 Plaster Walls and Ceilings 600 sq. ft. --- --- --- Negative --- --- None --- 1 3 213 Room 3287 Base Trim - 6" - Black 8 sq. ft. --- --- --- Negative --- --- None --- 1 3 213 Room 3287 Ceramic Tile --- --- --- --- --- --- --- --- None --- 1 3 213 Room 3287 Concrete Block Wall --- --- --- --- --- --- --- --- None --- 1 3 213 Room 3287 Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 3 213 Room 3287 Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 176 sq. ft. --- --- --- Negative --- --- None ---

1 3 213 Room 3287 Floor Tile - 12"x12" - Cream with Grey Flakes with Mastic 176 sq. ft. --- --- --- Negative --- --- None ---

1 3 213 Room 3287 Mudded Fitting - 3rd Floor 2 fitting

(s) --- --- 16297-1-74.1 40% Amosite 3 M

Patch & Repair

Near center of room, above drop ceiling tile, open ends.

1 3 213 Room 3287 Plaster Walls and Ceilings 160 sq. ft. --- --- --- Negative --- --- None --- 1 3 213 Room 3287 Wood Doors - No Fire Tags 1 door (s) --- --- --- --- --- --- None ---

1 3 89 Rooms 3142 &

3142A Ceramic Tile --- --- --- --- --- --- --- --- None ---

1 3 89 Rooms 3142 &

3142A Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 3 89 Rooms 3142 &

3142A Drywall Drop Ceiling Tiles 400 sq. ft. --- --- --- Negative --- --- None ---

1 3 89 Rooms 3142 &

3142A Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 3 89 Rooms 3142 &

3142A Paper Pipe Insulation (Aircell) 30 ln. ft. --- --- --- Positive 7 L O & M

(1) vertical line in SE corner chase (2) vertical lines in west wall for sink

1 3 89 Rooms 3142 &

3142A Plaster Walls and Ceilings 400 sq. ft. --- --- --- Negative --- --- None ---

1 3 89 Rooms 3142 &

3142A Wood Fire Doors with Fire Tag 1 door (s) --- --- Assumed Assumed 7 L O & M ---

1 3 298 SW Mechanical

Shaft Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 4 177 ICU Mechnical

Room Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- ---

1 4 192 NE Mechanical

Room Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- ---

1 4 220 NW Mechanical

Shaft Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 4 243 Room 4107 Paper Pipe Insulation (Aircell) 24 ln. ft. --- --- --- Positive 7 L O & M

(3) lines in NW and center wall chases

1 4 242 Room 4111 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 242 Room 4111 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NE corner chase 1 4 254 Room 4116 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M Under construction 1 4 229 Room 4127 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 221 Room 4128 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SW corner chase 1 4 222 Room 4130 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 228 Room 4131 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 241 Room 4131P Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 223 Room 4132 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 224 Room 4134 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NW corner chase 1 4 225 Room 4136 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SW corner chase 1 4 227 Room 4137 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 226 Room 4138 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 87 Room 4143 Ceramic Tile --- --- --- --- --- --- --- --- None --- 1 4 87 Room 4143 Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 4 87 Room 4143 Drywall Drop Ceiling Tiles 36 sq. ft. --- --- --- Negative --- --- None

(1) vertical line in NE corner of bath

1 4 87 Room 4143 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None fiberglass lines in wall to sink

1 4 87 Room 4143 Paper Pipe Insulation (Aircell) 10 ln. ft. --- --- --- Positive 7 L O & M --- 1 4 87 Room 4143 Plaster Walls and Ceilings 360 sq. ft. --- --- --- Negative --- --- None --- 1 4 87 Room 4143 Wood Doors - No Fire Tags 1 door (s) --- --- --- --- --- --- None --- 1 4 175 Room 4144 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- Nothing to note 1 4 172 Room 4145 Paper Pipe Insulation (Aircell) 6 ln. ft. --- --- --- Positive 7 L O & M ---

1 4 171 Room 4147 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None Drywall chases, NW, SW

1 4 174 Room 4148 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None SE, NE, fiberglass

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 4 170 Room 4149 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- 16297-1-6.1 7 L O & M NE corner chase

1 4 173 Room 4150 Paper Pipe Insulation (Aircell) 6 ln. ft. --- --- --- Positive 7 L O & M SW corner, NW corner chases

1 4 169 Room 4151 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M NW corner, SW corner chases

1 4 230 Room 4162 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 4 232 Room 4165 Paper Pipe Insulation (Aircell) 32 ln. ft. --- --- --- Positive 7 L O & M NE corner chase and north wall

1 4 240 Room 4166 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 233 Room 4169 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 239 Room 4170 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 234 Room 4171 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 238 Room 4172 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 235 Room 4173 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SE corner chase

1 4 236 Room 4175 Paper Pipe Insulation (Aircell) 24 ln. ft. --- --- --- Positive 7 L O & M NE, SE, and SW corner chases

1 4 237 Room 4177 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SW corner chase 1 4 253 Room 4188 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M Under construction 1 4 251 Room 4198 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 4 244 Room 4205 Paper Pipe Insulation (Aircell) 0 ln. ft. --- --- --- --- --- --- None Lines have been removed

1 4 245 Room 4211 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M Assumed, room in use 1 4 246 Room 4215 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M Assumed, room in use 1 4 248 Room 4216 Paper Pipe Insulation (Aircell) 32 ln. ft. --- --- --- Positive 7 L O & M Center chase 1 4 247 Room 4217 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NE corner chase 1 4 200 Room 4225 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NW corner chase

1 4 193 Room 4228 Paper Pipe Insulation (Aircell) 24 ln. ft. --- --- --- Positive 7 L O & M W, E, corners, assumed 1 4 199 Room 4229 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- --- 1 4 194 Room 4230 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M NE corner chase 1 4 198 Room 4233 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M NW corner chase

1 4 195 Room 4234 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M NE and SE corner chases

1 4 196 Room 4236 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M SW and SE corner chases

1 4 197 Room 4237 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M NW and SW corner chases

1 4 190 Room 4242, 4252 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M NE, SE corners of 4252 1 4 191 Room 4243 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- ---

1 4 189 Room 4245 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M NE, NW, corner chases, assumed

1 4 188 Room 4246 Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 7 L O & M SE corner

1 4 187 Room 4250 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M SE corner and SW corner, assumed

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 4 186 Room 4251 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- ---

1 4 186 Room 4251 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M NE and NW corner chases

1 4 185 Room 4260, 4230 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- ---

1 4 185 Room 4260, 4230 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M North end of hallway W, E chases

1 4 176 Room 4262 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- --- 1 4 178 Room 4268 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- --- 1 4 183 Room 4269 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- --- 1 4 179 Room 4270 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- ---

1 4 182 Room 4271, 4271A Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- --- 1 4 181 Room 4273 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L W wall chase 1 4 180 Room 4277 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- ---

1 4 180 Room 4277 Paper Pipe Insulation (Aircell) 6 ln. ft. --- --- --- Positive 7 L O & M South center exterior wall - Aircell

1 4 250 Room 4294 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 249 Room 4296 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 4 184 Room4265 Fiberglass Insulated Lines --- --- --- --- --- --- --- --- --- --- 1 4 184 Room4265 Paper Pipe Insulation (Aircell) 16 ln. ft. --- --- --- Positive 7 L O & M NW Chase

1 4 86 Rooms 4142 &

4142A Ceramic Tile --- --- --- --- --- --- --- --- None ---

1 4 86 Rooms 4142 &

4142A Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 4 86 Rooms 4142 &

4142A Drywall Drop Ceiling Tiles 84 sq. ft. --- --- 16297-1-25.1 None

Detected --- --- None ---

1 4 86 Rooms 4142 &

4142A Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 4 86 Rooms 4142 &

4142A Paper Pipe Insulation (Aircell) 30 ln. ft. --- --- --- Positive 7 L O & M

(1) vertical line in SE corner chase. (2) vertical lines for wash sink

1 4 86 Rooms 4142 &

4142A Plaster Walls and Ceilings 400 sq. ft. --- --- 16297-1-3.3 None

Detected --- --- None ---

1 4 86 Rooms 4142 &

4142A Wood Fire Doors with Fire Tag 1 door (s) --- --- Assumed Assumed 7 L O & M ---

1 4 252 South

Mechanical Shaft Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 4 231 SW Mechanical

Shaft Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 5 25 5299D-1 Corridor Base Trim - 4" - Tan 39 sq. ft. --- --- --- Negative --- --- None ---

1 5 25 5299D-1 Corridor Brick Walls --- --- --- --- --- --- --- --- None ---

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 5 25 5299D-1 Corridor Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 5 25 5299D-1 Corridor Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 576 sq. ft. --- --- --- Negative --- --- None ---

1 5 25 5299D-1 Corridor Drywall 1,300 sq. ft. --- --- --- Negative --- --- None ---

1 5 25 5299D-1 Corridor Drywall Joint Compound 1,300 sq. ft. --- --- --- Negative --- --- None ---

1 5 25 5299D-1 Corridor Floor Tile - 12"x12" - Cream with Grey Flakes with Mastic 576 sq. ft. --- --- --- Negative --- --- None ---

1 5 25 5299D-1 Corridor Plaster Walls and Ceilings 1,300 sq. ft. --- --- --- Negative --- --- None ---

1 5 25 5299D-1 Corridor Wood Doors - No Fire Tags 1 door (s) --- --- --- --- --- --- None ---

1 5 66 Cooridor 5299C-1

Hallway Ceramic Tile --- --- --- --- --- --- --- --- None ---

1 5 66 Cooridor 5299C-1

Hallway Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 5 66 Cooridor 5299C-1

Hallway Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 408 sq. ft. --- --- --- Negative --- --- None ---

1 5 66 Cooridor 5299C-1

Hallway Floor Tile - 12"x12" - Cream with Grey Flakes with Mastic 408 sq. ft. --- --- --- Negative --- --- None ---

1 5 66 Cooridor 5299C-1

Hallway Metal Fire Door with Fire Tag 2 door (s) --- --- Assumed Assumed 7 L O & M Entrance doors

1 5 66 Cooridor 5299C-1

Hallway Plaster Walls and Ceilings 1,100 sq. ft. --- --- --- Negative --- --- None --- 1 5 13 Directors Offices Base Trim - 4" - Cream 90 sq. ft. --- --- --- Negative --- --- None --- 1 5 13 Directors Offices Carpet --- --- --- --- --- --- --- --- None --- 1 5 13 Directors Offices Ceramic Tile --- --- --- --- --- --- --- --- None --- 1 5 13 Directors Offices Concrete Ceiling --- --- --- --- --- --- --- --- None --- 1 5 13 Directors Offices Concrete Slab Floor --- --- --- --- --- --- --- --- None Under carpet.

1 5 13 Directors Offices Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 1,600 sq. ft. --- --- --- Negative --- --- None --- 1 5 13 Directors Offices Drywall 2,980 sq. ft. --- --- --- Negative --- --- None --- 1 5 13 Directors Offices Drywall Joint Compound 2,980 sq. ft. --- --- --- Negative --- --- None --- 1 5 13 Directors Offices Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 5 13 Directors Offices Metal Fire Door with Fire Tag 1 door (s) --- --- Assumed Assumed 7 L O & M ---

1 5 13 Directors Offices Paper Pipe Insulation (Aircell) 20 ln. ft. --- --- --- Positive 7 L O & M

(2) Vertical lines in south wall of secretary's area. (1) Vertical line in rooms' 5250, 5249, and 5245.

1 5 13 Directors Offices Pipe Wrap - Black 12 ln. ft. --- --- 16297-1-29.1 None

Detected 6 M O & M

Mechanical shaft next to room 5243, storage area.

BDN Project No. 16297

January 2015

Asbestos Management Plan Project NO: 585-14-111

Building #1

Bldg Number Floor

Space Code Space Name Description of Material

Quantity in Space

Quantity Damaged

Sample Number/

Photo Number

Sample Result

Hazard Ranking

Potential for Disturbance Response Notes

1 5 13 Directors Offices Plaster Walls and Ceilings 220 sq. ft. --- --- --- Negative --- --- None --- 1 5 13 Directors Offices Wood Doors - No Fire Tags 6 door (s) --- --- --- --- --- --- None ---

1 5 13 Directors Offices Wood Fire Doors with Fire Tag 1 door (s) --- --- Assumed Assumed 7 L O & M Room 5243.

1 5 80 Main Hallway Base Trim - 4" - Brown 55 sq. ft. --- --- --- Negative --- --- None West end near surgery 1 5 80 Main Hallway Base Trim - 6" - Black 20 sq. ft. --- --- --- Negative --- --- None --- 1 5 80 Main Hallway Brick Walls --- --- --- --- --- --- --- --- None --- 1 5 80 Main Hallway Concrete Ceiling --- --- --- --- --- --- --- --- None --- 1 5 80 Main Hallway Concrete Ceiling --- --- --- --- --- --- --- --- None ---

1 5 80 Main Hallway Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 2,256 sq. ft. --- --- --- Negative --- --- None ---

1 5 80 Main Hallway Drop Ceiling Tile - 2'x2' - White -

Dot - Wormy 184 sq. ft. --- --- --- Negative --- --- None --- 1 5 80 Main Hallway Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None --- 1 5 80 Main Hallway Fiberglass Insulated Lines --- --- --- --- --- --- --- --- None ---

1 5 80 Main Hallway Floor Tile - 12"x12" - Cream with Grey Flakes with Mastic 2,256 sq. ft. --- --- --- Negative --- --- None ---

1 5 80 Main Hallway

Floor Tile - 12"x12" - Light Green with Grey Streaks with

Mastic 184 sq. ft. --- --- ---

Tile and Mastic

Negative --- --- None ---

1 5 80 Main Hallway Mag Pipe Insulation 8 sq. ft. --- --- 16297-1-51.3

30% Amosite 10%

Chrysotile 6 M O & M Above DCT in hallway.

1 5 80 Main Hallway Paper Pipe Insulation (Aircell) 8 ln. ft. --- --- --- Positive 6 M O & M

(1) Horizontal line above DCT near Room…