This federal contract opportunity solicitation requests contractor services to perform infrastructure upgrades and renovations at the St. Cloud Veterans Affairs Health Care System facilities. The solicitation seeks a contractor to furnish all labor, materials, tools and equipment for electrical, bonding, UPS, building management system interfaces, access security, and HVAC assessments and upgrades. Additional requirements include data center/main server room physical security upgrades, installing a diversified fiber path to the data center for the WAN, and accessing and upgrading the fiber infrastructure backbone campus-wide within and between buildings. The solicitation also includes hazardous materials abatement. All work must be completed according to specifications and contract drawings. The issuing agency is the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation number is 36C77622B0035.
View the file
Other files for this federal contract opportunity
Show all 50
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING FIBER - INSIDE
VFY EXIST
EXISTING FIBER - OUTSIDE
VFY EXIST
FIBER ROUTE - INSIDE
SEE TELECOM
FIBER ROUTE - OUTSIDE
SEE CIVIL
BUILDING OUTLINE
VFY EXIST
CORRIDOR OUTLINE
VFY EXIST
LEGEND
TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST
44TH AVE.
TRAIL 1
TRAIL 2
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2)
15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
GRAVEL
GRAVEL
GRAVEL
EXISTING
ROAD
CHAIN LINK FENCE
CHAIN LINK FENCE
16' GATE
GRAVEL
ELECTRICAL
SUBSTATION
G E N E R A T O R
FUEL LINES
CONDU ITS TO TU NNEL
M V
D U
C T
B A
N K
1 1 2 W
PHARMACY ADDITION
11 2 E
G E N E R A T O R
B
CORRIDOR LINK
A
C T
TR
A
IL
ER
174 s .f.
256 s .f.
185 s .f.
149 s ..f.
155 s .f.
104 s .f.
70 s. .f .
72 s .f.
110 s .f.
276 s .f.
112 s .f.
99 s .f.
57 s .f.
146 s .f.
434 s .f.
R A
MP
U P
1:
M A X
R A
MP
U P
1:
M A X
RA
M P
UP
1:2 0 M
AX
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2) 15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
.3
TRANSFORMER
BUILD ING
#91
5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN
O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW
C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D
P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S
R EC O M M EN D ATIO N S
N EW G AS SU P P LY M AIN
IN TO B U ILD IN G
SP AR E
P H O N E LIN E
EXTEN D S TO
E XISTIN G
P H O N E IN
B O ILER R O O M
P ER P LAN .
SP AR E
P H O N E
LIN E TO
M ETER
TU N N EL
E XTEN D S
A D D ITIO N AL
2'- 0" U N D ER
B U ILD IN G
FUEL LINE
VENT LINE
1,000 GAL.
UNDERGROUND
DIESEL FUEL
TANK
1,000/5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
S 1
LIG H T
N EW G AS SU P P LY
(C O O R D IN ATE W ITH SU P P LIER )
12"D
10"D
"D
TP TP
EXIST. BUILDING
EXIST.
BUS STOP
CC
L O
O P
16"
20"
12"
3"
8"
DN
0.
0’
BIRDCAGE
B
IR
D C
A G
E
NSP ELECTRICAL
FOR HWY DEPT
T101
I.T.
CHILLER
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
VESTIBULE
DN
DN
DN
FD
DN
F B
F
B
F B
F
B
F B
F
B
SOUTH
VESTIBULE
PASS
THROUGH
LINK TO
BUILDI NG 51
6 3. 32 56
1 13 5. 35 78
PARKING
NO
PARKING
93 49
37 6
109 5
1A
S M
O K
E B
L D
G
SMOKE
BLDG
SMOKE
BLDG
S M
O K
E B
L D
G
SMOKE
BLDG
M.H.
STOR.
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
STOR.
BIO-
HAZ.
SAUK RIVER
GP
HOLDING POND
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
OWNER AND
CONSULTANTS:
CONTACT:
ADDRESS:
MIKE ENGMARK
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
NAME:
ADDRESS:
CONTACT:
ADVANCED STRUCTURAL TECHNOLOGIES
7301 OHMS LANE; SUITE 215
EDINA, MN 55439
ZACHARY CRAIG
PHONE:
NAME:
ADDRESS:
CONTACT:
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
PHONE: 402-991-5520
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
IAN WEBER
763-412-4000
ARCHITECT:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
EDWARD MARKFORT
763-412-4000
952-854-9302
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
402-991-5520
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
COVER
DATE:
APPROVED: APPROVED: PROJECTS SECTION MANAGER
APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:
APPROVED: SAFETY MANAGER
APPROVED: CHIEF OF POLICE
APPROVED: PATIENT SAFETY
DATE:
DATE:
DATE: APPROVED: EMS MANAGER
APPROVED: M/O MANAGER
DATE:
DATE:
DATE:DATE:
APPROVED: MEDICAL CENTER DIRECTOR
APPROVED: PROJECT COR DATE:
APPROVED: INFECTION CONTROL NURSE DATE:
APPROVED: SERVICE LINE DIRECTOR
APPROVED: GEMS COORDINATOR DATE:
DATE:
APPROVED: NURSE EXECUTIVE
APPROVED: CHIEF OF STAFF DATE:
APPROVED: DIRECTOR FMS
APPROVED: ASSOCIATE DIRECTOR
DATE:
DATE:
DATE:
DATE:APPROVED: DATE:
APPROVED: DATE:
APPROVED: DATE:
Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System
N
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
VICINITY MAP:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHONE: 320-252-1670
CIVIL ENGINEER:
VA COR:
TELECOMMUNICATIONS ENGINEER:
CONTACT:
ADDRESS:
JONATHAN WEST
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
PHONE: 504-250-2699
PROGRAM MANAGER:
EMAIL: Jonathan.West@vciint.com
STRUCTURAL ENGINEER:
MECH/ELEC/PLUMB/FIRE ENGINEER:
C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -3
-R E
M a rk fo rt
.r v t
/2
/2
:1
:2
A
M
3-GI000
BUILDING 3 COVER SHEET &
SHEET INDEX
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
BUILDING 3 - EHRM INFRASTRUCTURE UPGRADES
03/30/2022
0APPROX 150' 300'75'
SHEET INDEX - BUILDING 3
SHEET NO. SHEET TITLE
3-GI000 BUILDING 3 COVER SHEET & SHEET INDEX
3-GI111 FIRST FLOOR - INFECTION CONTROL & PHASING PLAN
3-GI121 SECOND FLOOR INFECTION CONTROL & PHASING PLAN
3-HA-1A REFERENCE - BASEMENT FLOOR ASBESTOS RE-SURVEY
3-HA-2A REFERENCE - FIRST FLOOR ASBESTOS RE-SURVEY
3-HA-3A REFERENCE - SECOND FLOOR ASBESTOS RE-SURVEY
3-HA-4A REFERENCE - THIRD FLOOR / ATTIC ASBESTOS RE-SURVEY
3-AS110 BASEMENT AND FIRST FLOOR PLANS
3-AS120 SECOND FLOOR AND ATTIC PLANS
3-TD100 BASEMENT & FIRST FLOOR PLANS - TELECOM - DEMOLITION
3-TD120 SECOND & THIRD FLOOR PLANS - TELECOM - DEMOLITION
3-TN100 BASEMENT & FIRST FLOOR PLANS - TELECOMMUNICATIONS
3-TN120 SECOND & THIRD FLOOR PLANS - TELECOMMUNICATIONS
3-TN210 FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE
3-TN220 SECOND FLOOR PLAN - TELECOM - CABLE DISTANCE
3-TN300 ENLARGED PLANS - TELECOMMUNICATIONS - DEMO
3-TN400 ENLARGED PLANS - TELECOMMUNICATIONS
3-TN401 ENLARGED PLANS - TELECOMMUNICATIONS
03-E200 BASEMENT FLOOR PLAN - ELECTRICAL
03-E201 FIRST FLOOR - ELECTRICAL
03-E202 SECOND FLOOR - ELECTRICAL
03-E300 ELECTRICAL ENLARGED PLANS
03-E400 ELECTRICAL RISER DIAGRAMS
03-E500 ELECTRICAL SCHEDULES
03-M101 FIRST FLOOR DEMOLITION - MECHANICAL
03-M102 SECOND FLOOR DEMOLITION - MECHANICAL
03-M201 FIRST FLOOR - MECHANICAL
03-M202 SECOND FLOOR REMODEL - MECHANICAL
SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION
ROOM SCHEDULE
NO. NAME C
A
B
LI
N G
P A
T C
H P
A N
E L
F
IB
E R
P O
W E
R
B O
N D
IN
G
U P
S
D E
D
IC
A T
E D
C O
O
LI
N G
T E
M P
E R
A T
U R
E
H U
M
ID
IT
Y
R A
C K
S E
N S
O R
S P
A C
E
AREA
WIDTH
(FT)
LENGTH
(FT) REMARKS
FIRST FLOOR
109 TELECOM ROOM 43 SF 5.4 8.0 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM
ROOM STANDARDS. SEE TELECOM DRAWINGS
SECOND FLOOR
205E TELECOM ROOM X X X X X X 81 SF 7.3 11.2 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM
ROOM STANDARDS. SEE TELECOM DRAWINGS
OPENING SCHEDULE
VA Building Number
ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION
H D
W G
R O
U P
F
IR
E L
A B
E L
(M
IN
G A
S K
E T
E
LE
C T
R
IC
A L
S L
A B
E L
COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT
PANEL
TYPE
2ND
PANEL
TYPE
PANEL
GLAZING FRAME TYPE
FRAME
GLAZING
HAZARDOUS MATERIAL SCHEDULE
LEVEL
ROOM
NO. ROOM NAME
QUESTIONABLE HAZARDOUS
ELEMENT POSSIBLE ABATEMENT ACTION
FIRST FLOOR 109 TELECOM ROOM NONE. SEE 3-HA-1A NONE. ACM TO REMAIN UNDISTURBED
SECOND FLOOR 205E TELECOM ROOM NONE. SEE 3-HA-2A NONE. ACM TO REMAIN UNDISTURBED
HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT
DISTURB QUESTIONABLE HAZARDOUS MATERIAL.
LEAK PREVENTION / DIVERTER SCHEDULE
LEVEL
ROOM
NO. ROOM NAME OVERHEAD LEAK DIVERTER AND DRAIN PIPING LEAK PREVENTION BARRIER WATERPROOFING
FIRST FLOOR 109 TELECOM ROOM
SECOND FLOOR 205E TELECOM ROOM MWP INT: WEST
SEE GENERAL NOTES SHEET FOR DETAIL. MWP = MEMBRANE WATERPROOFING. MASONRY = FLUID-APPLIED WATERPROOFING. INT = INTERIOR. EXT = EXTERIOR
ICRA PHASE CONSTRUCTION ROOM SCHEDULE
LEVEL
ROOM
NO. ROOM NAME
CAI BLDG NAME /
FUNCTION
CONSTRUCTION
PROJECT ACTIVITY
INFECTION CONTROL
RISK GROUP
CONTROL
PROCEDURE CLASS SECTION
CONSTRUCTION ZONE /
OCCUPIED CONSTR
DAY /
NIGHT
FIRST FLOOR 109 TELECOM ROOM DENTAL TYPE C GROUP 1 CLASS II WEST OCCUPIED CONSTRUCTION NIGHT
SECOND FLOOR 205E TELECOM ROOM ADMINISTRATIVE TYPE C GROUP 1 CLASS II WEST OCCUPIED CONSTRUCTION NIGHT
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
POSSIBLE
PRINTER
LOCATION
24X24
D E
S K
X
T A
B L E
X
DENTAL
LAB
DENTAL
LAB
121A
CORRIDOR
C1F
MULTI
PURPOSE
OFFICE
CORRIDOR
C1C
CORRIDOR
C1E
VESTIBULE
VESTIBULE
STAIR
HALL
OPERATORY
EQUIP
DIGITAL
103A
STAIR
INSTRUMENT
PREP
CORRIDOR
C1B
CORRIDOR
C1A
DENTAL
LAB
DENTAL
LAB
121A
STAIR
HALL
STAIR
OPERATORY
STAFF
TOILET
LOCKER
SPS
RECEIVING
103B
DIGITAL/
PAN
OFFICE
OPERATORY
CLEAN
SPD
OFFICE
122 LOCKERS
DENTAL
CHIEF
ORAL
SURGERY
STAIR
SPS
RECEIVING
CLEAN
UTILITY
CORRIDOR
C1D
WAITING
WOMENS
TOILET
126B
MENS
TOILET
126A
POLISHER
INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND
LIMITS OF CONSTRUCTION
1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER
LOCATION, AND DOOR, WHERE SHOWN
TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER
LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.
UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -3
-R E
M a rk fo rt
.r v t
/2
/2
:1 :1
A
M
3-GI111
FIRST FLOOR - INFECTION
CONTROL & PHASING PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM BMW
16305
03/30/2022
1/8" = 1'-0"
FIRST FLOOR - CONST BARRIER PLAN
ROOM ICRA SCHEDULE
LEVEL
ROOM
NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS
FIRST FLOOR 109 TELECOM ROOM DENTAL TYPE C GROUP 1 CLASS II
SECOND FLOOR 205E TELECOM ROOM ADMINISTRATIVE TYPE C GROUP 1 CLASS II
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
N
0 8' 16'4'
D E
S K
30x66
D E
S K x6
LAT. FILE LAT. FILE
LAT. FILE LAT. FILE
LA
T
. F
IL
E
LAT. FILE
Key Cabinet
LAT. FILED
E
S K x6
Copier
ROOM
PLANS
211A
ROOM
PLOT/COPY
OFFICE
HAC
OFFICE
CORRIDOR
207A
OFFICE
207B
OFFICE
207C
CONFERENCE
STAIR
OFFICE
205A
OFFICE
205B
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
215B
OFFICE
215A
OFFICE
ALCOVE
213C
OFFICE
213B
OFFICE
213A
HOUSEKEEPING
OFFICE
CORRIDOR
OFFICE
C2C
CORRIDOR
OFFICE
OFFICE
OFFICE
OFFICE
WOMEN
MEN
205D
OFFICE
C2D
CORRIDOR
STAIR
221A
STAIR
LOBBY
205C
PASSAGE
INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND
LIMITS OF CONSTRUCTION
1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER
LOCATION, AND DOOR, WHERE SHOWN
TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER
LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.
UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -3
-R E
M a rk fo rt
.r v t
/2
/2
:1 :0
A
M
3-GI121
SECOND FLOOR INFECTION
CONTROL & PHASING PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM BMW
16305
03/30/2022
1/8" = 1'-0"
SECOND FLOOR - CONST BARRIER PLAN
ROOM ICRA SCHEDULE
LEVEL
ROOM
NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS
FIRST FLOOR 109 TELECOM ROOM DENTAL TYPE C GROUP 1 CLASS II
SECOND FLOOR 205E TELECOM ROOM ADMINISTRATIVE TYPE C GROUP 1 CLASS II
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
-ASBESTOS-CONTAINING WRAP (FELT) ON PIPE GOING INTO SOIL
-ASBESTOS-CONTAINING WINDOW CAULK
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
LEGEND BUILDING #3 - BASEMENT FLOOR PLAN
-ASBESTOS-CONTAINING FIRE DOOR
-ASBESTOS-CONTAINING TILE AND MASTIC
-ASBESTOS-CONTAINING WINDOW CAULK
-ASBESTOS-CONTAINING INSULATION INSIDE CONVECTORS
-ASBESTOS-CONTAINING WALL MASTIC
-ASBESTOS-CONTAINING COUNTERTOP
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
LEGEND
BUILDING #3 - FIRST FLOOR PLAN
-ASBESTOS-CONTAINING FIRE DOOR
-ASBESTOS-CONTAINING WINDOW CAULK
-ASBESTOS-CONTAINING INSULATION INSIDE CONVECTORS
-ASBESTOS-CONTAINING WALL MASTIC
-ASBESTOS-CONTAINING FLOOR TILE AND MASTIC BENEATH CARPET
-ASBESTOS-CONTAINING MASTIC BENEATH CARPET
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
LEGEND
BUILDING #3 - SECOND FLOOR PLAN
CASTLE HILL ASSOCIATES, LLC.
S
W E
BUILDING #3 - ATTIC FLOOR PLAN
POSSIBLE
PRINTER
LOCATION
24X24
D E
S K
X
T A
B L E
X
XFMR
MECHANICAL
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UP
DN
7'-11 5/8"
5' -5
3-AS110
TELECOM
ROOM 109
TELECOM
ROOM
TELECOM
ROOM
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -3
-R E
M a rk fo rt
.r v t
/2
/2
:1 :0
A
M
3-AS110
BASEMENT AND FIRST FLOOR
PLANS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
03/30/2022
1/8" = 1'-0"
FIRST FLOOR - OVERALL PLAN
1/8" = 1'-0"
BASEMENT FLOOR - OVERALL PLAN
N
0 8' 16'4'
N
0 8' 16'4'
N
0 4' 8'2' 1/4" = 1'-0"
DEMOLITION PLAN - RM109
_DEMOLITION PLAN KEYED NOTES
DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM
REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_FLOOR PLAN KEYED NOTES
FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”
TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH
HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT
FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT
OVER FIRE RATING STAMP.
FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE
TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST
THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS
WITH FIRE CAULK.
FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.
FL22 LEAK PREVENTION BARRIER WATERPROOFING DETAIL AT EXISTING
PARTITION. SEE AS601.
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_REFLECTED CEILING PLAN KEYED NOTES
RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET
ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE
VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET
ROW OR SECTION.
RC2 OPEN TO STRUCTURAL FLOOR ABOVE
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTORWITHIN TELECOM
ROOMS.
1/4" = 1'-0"
ENLARGED FLOOR PLAN - RM 109
N
0 4' 8'2' 1/4" = 1'-0"
REFLECTED CEILING PLAN - RM109
N
0 4' 8'2'
RC1 RC2
FL1
FL20
FL3
DE1
DE1
DE1
NORTH
E
S K
30x66
D E
S K x6
LAT. FILE LAT. FILE
LAT. FILE LAT. FILE
LA
T
. F
IL
E
LAT. FILE
Key Cabinet
LAT. FILED
E
S K x6
Copier
ROOM
PLANS
211A
ROOM
PLOT/COPY
OFFICE
HAC
OFFICE
CORRIDOR
207A
OFFICE
207B
OFFICE
207C
CONFERENCE
STAIR
OFFICE
205A
OFFICE
205B
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
215B
OFFICE
215A
OFFICE
ALCOVE
213C
OFFICE
213B
OFFICE
213A
HOUSEKEEPING
OFFICE
CORRIDOR
OFFICE
C2C
CORRIDOR
OFFICE
OFFICE
OFFICE
OFFICE
WOMEN
MEN
205D
OFFICE
C2D
CORRIDOR
STAIR
221A
STAIR
LOBBY
205C
PASSAGE
DN
SEE ROOF PLAN
SEE ROOF PLAN
ELEV
MACH
STAIR
MECH.
EQUIP.
ATTIC
ATTIC
ACCESS
PASSAGE
205E
TELECOM
ROOM
7' -3
/4
11'-2 1/4"
3-AS120
205E
TELECOM
ROOM
205E
TELECOM
ROOM
TELECOM
ROOM
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -3
-R E
M a rk fo rt
.r v t
/2
/2
:1 :0
A
M
3-AS120
SECOND FLOOR AND ATTIC
PLANS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
03/30/2022
1/8" = 1'-0"
SECOND FLOOR - OVERALL PLAN
N
0 8' 16'4' 1/8" = 1'-0"
ATTIC FLOOR - OVERALL PLAN
N
0 8' 16'4'
1/4" = 1'-0"
ENLARGED FLOOR PLAN - RM 205E
1/4" = 1'-0"
DEMOLITION PLAN - RM 205E
N
0 4' 8'2'
N
0 4' 8'2' 1/4" = 1'-0"
REFLECTED CEILING PLAN - RM 205E
N
0 4' 8'2'
DE1
RC1
_DEMOLITION PLAN KEYED NOTES
DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM
REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_FLOOR PLAN KEYED NOTES
FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”
TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH
HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT
FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT
OVER FIRE RATING STAMP.
FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE
TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST
THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS
WITH FIRE CAULK.
FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.
FL22 LEAK PREVENTION BARRIER WATERPROOFING DETAIL AT EXISTING
PARTITION. SEE AS601.
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_REFLECTED CEILING PLAN KEYED NOTES
RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET
ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE
VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET
ROW OR SECTION.
RC2 OPEN TO STRUCTURAL FLOOR ABOVE
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
DE1
DE1
FL1
FL22
FL20
FL3
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTORWITHIN TELECOM
ROOMS.
RC2
R A M P
D N
R A M P
D N
UNEXCAVATED
UNEXCAVATED
PASSAGE
STAIR
SUMP
ELEC
MECHANICAL
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
NORTH
UP
DN
POSSIBLE
PRINTER
LOCATION
24X24
D E
S K
X
T A
B L E
X
POLISHER
POSSIBLE
PRINTER
LOCATION
24X24
D E
S K
X
T A
B L E
X
POLISHER
LIMITS OF DATA CABLING DEMOLITION
3"
E
EXISTING CONDUIT FROM
BUILDING 3 TO BUILDING 1
3-TN300
LIMITS OF DATA CABLING DEMOLITION
2D/1
4D4D 4D4D4D
4D/1
1D
2D 2D 2D 2D 2D
2D
3D
3D
3D
1D
1D/1
4D
4D2D2D
2D 2D 2D 2D 2D 2D 2D
4D
4D 1V
4D2D
2D 4D
4D
4D
4D
2D
4D
4D
2D
3D 3D
3D3D3D
2D
2D
WAP
WAP
WAP
WAP
WAP
WAP
E E E E E
E
E
E E E E E E E E E
E
E
E
E
E
E
E
E
E
E E E E E E E
E
E
E
E
E
EE
E
EE
E E
E
E
E
E
E E E
EE
E
UP AND
DOWN
E
E E
E
E
E
E E
E
E
E
E
8"x4"
8"x4"
8" x4
8" x4
8"x4"
8" x4
E 8"x4"
E
8" x4
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
3-TD100
BASEMENT & FIRST FLOOR
PLANS - TELECOM -
DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/8" = 1'-0"
BASEMENT FLOOR PLAN - TELECOM - DEMOLITION
1/8" = 1'-0"
FIRST LEVEL FLOOR PLAN - TELECOM - DEMOLITION
N
0 8' 16'4'
N
0 8' 16'4'
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
C
ROOM
PLANS
211A
ROOM
PLOT/COPY
OFFICE
HAC
OFFICE
CORRIDOR
207A
OFFICE
207B
OFFICE
207C
CONFERENCE
STAIR
OFFICE
205A
OFFICE
205B
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
215B
OFFICE
215A
OFFICE
ALCOVE
213C
OFFICE
213B
OFFICE
213A
HOUSEKEEPING
OFFICE
CORRIDOR
OFFICE
C2C
CORRIDOR
OFFICE
OFFICE
OFFICE
OFFICE
WOMEN
MEN
205D
OFFICE
C2D
CORRIDOR
STAIR
221A
STAIR
LOBBY
205C
PASSAGE
DN
SEE ROOF PLAN
SEE ROOF PLAN
ELEV
MACH
STAIR
MECH.
EQUIP.
ATTIC
ATTIC
ACCESS
3-TN300
LIMITS OF DATA CABLING DEMOLITION
2D/12D/1
4D
4D
D
4D
3D/1
4D 2D/1 4D
2D/1 2D/1 2D/1
4D
4D
4D
4D 4D4D
4D
2D/12D/1
2D/1
2D/1
2D/1
4D
2D/1
2D/1
2D/1
4D
4D
4D
4D 4D
4D 4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
2D
2D/1
2D/1
2D/1
1D/1
WAP
WAP
WAP
WAP
WAP
EE
E
E
E
E
E
E
E E E
E
E
E
E
E E
E
E E
E
E
E
E E
E E
E
E
E
E
E
E
E E
E
E
E
E
E E E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E 12"x4" 12"x4"
"x
4"
"x
4"
12"x4"
"x
4"
E
EE
E
E
"x
4"
"x
4"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
3-TD120
SECOND & THIRD FLOOR
PLANS - TELECOM -
DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/8" = 1'-0"
SECOND FLOOR PLAN - TELECOM - DEMOLITION
1/8" = 1'-0"
THIRD FLOOR PLAN - TELECOM - DEMOLITION
N
0 8' 16'4'
N
0 8' 16'4'
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
XFMR
MECHANICAL
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UNEXCAVATED
UP
DN
POSSIBLE
PRINTER
LOCATION
24X24
D E
S K
X
T A
B L E
X
POSSIBLE
PRINTER
LOCATION
24X24
D E
S K
X
T A
B L E
X
LIMITS OF DATA CABLING
REPLACEMENT FROM ROOM 205E
2"
3"4"4"4"4"
4"4"4"4"
EXISTING CONDUIT FROM
BUILDING 3 TO BUILDING 1
2"
E
JUNCTION BOX
3"
4"4"4"4"
TELECOM ROOM
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 205E
4D
4D
4D
1V
4D
4D
3D
3D
3D
1D
1D/1
2D
1D
3D 3D 3D
3D3D
2D
2D
4D
4D 4D
2D 2D 2D 2D 2D 2D 2D 2D
4D 4D 4D 4D 4D
2D/1
4D/1 2D 2D 2D 2D 2D 2D 2D
WAP
WAP
WAP
WAP
WAP
WAP
2D
2D
2D
4D
4D
4D
E E E E E
E
E
E E E E E E E E E
E
E
E
E
E
E
E
E
E
E E E E E E E
E
E
E
E
E
EE
E
EE
E E
E
E
E
E
E E E
EE
E
HORIZONTAL AND
VERTICAL ROUTE TO
ROOM 205E
E
E E
8" x4
8" x4
8"x4"8"x4"
8" x4
8" x4
8"x4"
E
E
E
E E
E
E
E
E E
8" x4
8"x4"
3-TN400
E
C4
126"UPDOWN
2" F2
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
3-TN100
BASEMENT & FIRST FLOOR
PLANS -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/8" = 1'-0"
BASEMENT FLOOR PLAN - TELECOMMUNICATIONS
N
0 8' 16'4'
N
0 8' 16'4'
1/8" = 1'-0"
FIRST LEVEL FLOOR PLAN - TELECOMMUNICATIONS
N
0 8' 16'4'
N
0 8' 16'4'
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
SHEET NOTES:
1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.
2. PROVIDE JUNCTION BOX TO CONNECT FIBER CONDUIT ENTRY TO EXTEND CONDUIT PATHWAY TO THE NEW
TELECOM ROOM.
S K
30x66
D E
S K x6
LAT. FILE LAT. FILE
LAT. FILE LAT. FILE
LA
T
. F
IL
E
LAT. FILE
Key Cabinet
LAT. FILED
E
S K x6
Copier
ROOM
PLANS
211A
ROOM
PLOT/COPY
OFFICE
HAC
OFFICE
CORRIDOR
207A
OFFICE
207B
OFFICE
207C
CONFERENCE
STAIR
OFFICE
205A
OFFICE
205B
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
215B
OFFICE
215A
OFFICE
ALCOVE
213C
OFFICE
213B
OFFICE
213A
HOUSEKEEPING
OFFICE
CORRIDOR
OFFICE
C2C
CORRIDOR
OFFICE
OFFICE
OFFICE
OFFICE
WOMEN
MEN
205D
OFFICE
C2D
CORRIDOR
STAIR
221A
STAIR
LOBBY
205C
PASSAGE
D E
S K
30x66
D E
S K x6
LAT. FILE LAT. FILE
LAT. FILE LAT. FILE
LA
T
. F
IL
E
LAT. FILE
Key Cabinet
LAT. FILED
E
S K x6
Copier
ROOM
PLANS
211A
ROOM
PLOT/COPY
OFFICE
HAC
OFFICE
CORRIDOR
207A
OFFICE
207B
OFFICE
207C
CONFERENCE
STAIR
OFFICE
205A
OFFICE
205B
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
215B
OFFICE
215A
OFFICE
ALCOVE
213C
OFFICE
213B
OFFICE
213A
HOUSEKEEPING
OFFICE
CORRIDOR
OFFICE
C2C
CORRIDOR
OFFICE
OFFICE
OFFICE
OFFICE
WOMEN
MEN
205D
OFFICE
C2D
CORRIDOR
STAIR
221A
STAIR
LOBBY
205C
PASSAGE
C
DN
SEE ROOF PLAN
SEE ROOF PLAN
ELEV
MACH
STAIR
MECH.
EQUIP.
ATTIC
ATTIC
ACCESS
205E
TELECOM ROOM
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 205E
F2
C4 126"
2D/1 2D/1
2D/1 4D 2D/1 2D/1
2D/1
2D/1
2D/1
2D/1
1D/1
2D
4D
4D
2D/12D/1
2D/1
2D/1
2D/1 2D/1
2D/1
2D/1
4D
4D
D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D 4D
4D 4D
4D
4D
4D 4D
4D
4D
4D
3D/1
WAP
WAP
WAP
WAP
WAP
EE
E
E
E
E
E
E
E E E
E
E
E
E
E E
E
E E
E
E
E
E
E
E E
E
E
E
E
E
E
E E
E
E
E
E
E E E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
3-TN401
"x
4"
"x
4"
12"x4" 12"x4"
E
E
E
E
E
E
1 E
"x
4"
12"x4"
E2
E
E
12"x4"
"x
4"
"x
4"
F2
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
3-TN120
SECOND & THIRD FLOOR
PLANS -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/8" = 1'-0"
SECOND FLOOR PLAN - TELECOMMUNICATIONS
1/8" = 1'-0"
THIRD FLOOR PLAN - TELECOMMUNICATIONS
N
0 8' 16'4'
N
0 8' 16'4'
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
SHEET NOTES:
1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.
POSSIBLE
PRINTER
LOCATION
24X24
D E
S K
X
T A
B L E
X
POSSIBLE
PRINTER
LOCATION
24X24
D E
S K
X
T A
B L E
X
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:2
P
M
3-TN210
FIRST FLOOR PLAN -
TELECOM - CABLE DISTANCE
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1" = 30'-0"
FIRST FLOOR PLAN - TELECOMMUNICATIONS - CABLE DISTANCE
0 30' 60'15'
S K
30x66
D E
S K x6
LAT. FILE LAT. FILE
LAT. FILE LAT. FILE
LA
T.
F
IL
E
LAT. F ILE
Key Cabinet
LAT. F ILED
E
S K x6
Copier
ROOM
PLANS
211A
ROOM
PLOT/COPY
OFFICE
HAC
OFFICE
CORRIDOR
207A
OFFICE
207B
OFFICE
207C
CONFERENCE
STAIR
OFFICE
205A
OFFICE
205B
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
215B
OFFICE
215A
OFFICE
ALCOVE
213C
OFFICE
213B
OFFICE
213A
HOUSEKEEPING
OFFICE
CORRIDOR
OFFICE
C2C
CORRIDOR
OFFICE
OFFICE
OFFICE
OFFICE
WOMEN
MEN
205D
OFFICE
C2D
CORRIDOR
STAIR
221A
STAIR
LOBBY
205C
PASSAGE
D E
S K
30x66
D E
S K x6
LAT. FILE LAT. FILE
LAT. FILE LAT. FILE
LA
T.
F
IL
E
LAT. F ILE
Key Cabinet
LAT. F ILED
E
S K x6
Copier
ROOM
PLANS
211A
ROOM
PLOT/COPY
OFFICE
HAC
OFFICE
CORRIDOR
207A
OFFICE
207B
OFFICE
207C
CONFERENCE
STAIR
OFFICE
205A
OFFICE
205B
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
215B
OFFICE
215A
OFFICE
ALCOVE
213C
OFFICE
213B
OFFICE
213A
HOUSEKEEPING
OFFICE
CORRIDOR
OFFICE
C2C
CORRIDOR
OFFICE
OFFICE
OFFICE
OFFICE
WOMEN
MEN
205D
OFFICE
C2D
CORRIDOR
STAIR
221A
STAIR
LOBBY
205C
PASSAGE
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:3
P
M
3-TN220
SECOND FLOOR PLAN -
TELECOM - CABLE DISTANCE
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1" = 30'-0"
SECOND FLOOR PLAN - TELECOMMUNICATIONS - CABLE DISTANCE
0 30' 60'15'
F
PASSAGE
D
E
E
R
E
CABLE TRAY
DATA RACK
8"x4"
E R
D
E E R
W
E
CABLE TRAY
DATA RACK
R
E E
12"x4"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:3
P
M
3-TN300
ENLARGED PLANS -
TELECOMMUNICATIONS -
DEMO
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/4" = 1'-0"
ENALRGED PLAN - RM 109 - TELECOM - DEMO
0 4' 8'2'
N
1/4" = 1'-0"
ENALRGED PLAN - RM 205E - TELECOM - DEMO
0 4' 8'2'
N
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
SHEET NOTES:
1. EXISTING TELECOMMUNICATIONS CAGE AND RACK SHALL BE INCLUDED WITHIN THE SCOPE OF DEMOLITION.
EXISTING CABLING AND ASSOCIATED OUTLETS SHALL BE REMOVED AND REPLACED 1 FOR 1 AND REFED FROM DISTRIBUTION EQUIPMENT LOCATED WITHIN THE NEW TELECOMMUNICATIONS ROOM. REFER TO GENERAL CABLING NOTES FOR APPROXIMATE QUANTITIES. REFER TO NEW WORK PLANS FOR SERVING
COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE
RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE
PROJECT.
1. ROOM 109
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 185
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
2. ROOM 205E
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 192
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
R
A C
NOTES:
1. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.
2. COORDINATE EXACT RACK COUNT AND LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.
3. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL RACK COMPONENTS.
4. RACK ELEVATION SHOWS A FULLY CONFIGURED SAMPLE RACK. CONTRACTOR TO PROVIDE REQUIRED EQUIPMENT TO
SUPPORT THE FINAL DATA COUNT FROM THE ENLARGED NEW SHEET. (NOT TO EXCEED 288 PORTS PER RACK).
5. COORDINATE FINAL RACK COMPONENT LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.
6. CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE COUNT, QUANTITY OF PATCH PANELS, SWITCHES, FIBER ENCLOSURES, BLANKING PANELS, CABLE MANAGEMENT, AND MOUNTING HARDWARE NOT MARKED AS “OIT PROVIDED”.
7. PUNCHDOWN COPPER BACKBONES ON RACK MOUNT PATCH PANELS. TERMINATE ONE (1) PAIR PER PATCH PANEL PORT.
VERTICAL CABLE
MANAGEMENT (TYP)
RACK 1
1U 144 STRAND OM4 AND OS2 DISTRIBUTION PANEL
1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)
1U 48 PORT CAT5E BACKBONE PATCH PANEL
1U CABLE MANAGEMENT
1U CABLE MANAGEMENT
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
6U 5KW RACK MOUNT UPS
6U SPACE FOR FUTURE USE. PROVIDE BLANK
PANELS FOR UNUSED SPACES.
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
NEMA L21-20R (TYP)
CHANNEL RACK (TYP)
D
PROVIDE DATA CABLE TO RACK
MOUNTED UPS FOR CONNECTION
TO MONITORING SYSTEM
RACK 1
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
SPACE FOR FUTURE HORIZONTAL CABLE
DISTRIBUTION. PROVIDE BLANKING PANELS FOR
UNUSED SPACES.
3-TN400
1 - a b
1 - c d
TELECOM ROOM
W
12"x4"
12"x4" 12"x4"
C4 126"
12"x4" 12"x4"
DATA
RACK
CABLE
TRAY
12"x4"
KEYPAD
8"x4" E
2"
F2
R
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:3
P
M
3-TN400
ENLARGED PLANS -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 2' 4'1'
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.
THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED
FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE
PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.
1. ROOM 109
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 185
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6A): 185
DATA (CAT6): 0
NOT TO SCALE
COMMUNICATIONS - TYPICAL ONE RACK ELEVATION WITH RACK MOUNT UPS - TR 109
0 4' 8'2' 0 4' 8'2' 0 4' 8'2' 0 4' 8'2'1/4" = 1'-0"
1 - a
1/4" = 1'-0"
1 - b
1/4" = 1'-0"
1 - c
1/4" = 1'-0"
1 - d
1/2" = 1'-0"
ENLARGED PLAN - TR 109 - TELECOM - CABLE TRAY AND DATA
PASSAGEPASSAGE
F A
C
C R
C
205E
TELECOM ROOM
12" LADDER
3-TN401
2 - a b
2 - c d
12"x4"
12"x4"
DATA RACK
CABLE TRAY
E
W
E
C4 126"
E
F2
E
12"x4"12"x4"
W
K E
Y P
A D
12"x4"
E
F2
R
NOTES:
1. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.
2. COORDINATE EXACT RACK COUNT AND LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.
3. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL RACK COMPONENTS.
4. RACK ELEVATION SHOWS A FULLY CONFIGURED SAMPLE RACK. CONTRACTOR TO PROVIDE REQUIRED EQUIPMENT TO
SUPPORT THE FINAL DATA COUNT FROM THE ENLARGED NEW SHEET. (NOT TO EXCEED 288 PORTS PER RACK).
5. COORDINATE FINAL RACK COMPONENT LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.
6. CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE COUNT, QUANTITY OF PATCH PANELS, SWITCHES, FIBER ENCLOSURES, BLANKING PANELS, CABLE MANAGEMENT, AND MOUNTING HARDWARE NOT MARKED AS “OIT PROVIDED”.
7. PUNCHDOWN COPPER BACKBONES ON RACK MOUNT PATCH PANELS. TERMINATE ONE (1) PAIR PER PATCH PANEL PORT.
VERTICAL CABLE
MANAGEMENT (TYP)
RACK 1
1U 144 STRAND OM4 AND OS2 DISTRIBUTION PANEL
1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)
1U 48 PORT CAT5E BACKBONE PATCH PANEL
1U CABLE MANAGEMENT
1U CABLE MANAGEMENT
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
6U 5KW RACK MOUNT UPS
6U SPACE FOR FUTURE USE. PROVIDE BLANK
PANELS FOR UNUSED SPACES.
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
NEMA L21-20R (TYP)
CHANNEL RACK (TYP)
D
PROVIDE DATA CABLE TO RACK
MOUNTED UPS FOR CONNECTION
TO MONITORING SYSTEM
RACK 1
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
SPACE FOR FUTURE HORIZONTAL CABLE
DISTRIBUTION. PROVIDE BLANKING PANELS FOR
UNUSED SPACES.
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:0
:3
P
M
3-TN401
ENLARGED PLANS -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 2' 4'1'
0 4' 8'2' 0 4' 8'2' 0 4' 8'2' 0 4' 8'2'
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.
THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED
FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE
PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.
1. ROOM 205E
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 192
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 185 FROM ROOM 109
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6A): 192
DATA (CAT6): 0
1/2" = 1'-0"
ENLARGED PLAN - TR 205E - TELECOM - CABLE TRAY AND DATA
1/4" = 1'-0"
2 - a
1/4" = 1'-0"
2 - b
1/4" = 1'-0"
2 - c
1/4" = 1'-0"
2 - d
NO SCALE
COMMUNICATIONS - TYPICAL ONE RACK ELEVATION WITH RACK MOUNT UPS - TR 205E
B O
O K
S
B O
O K
S
B O
O K
S
B O
O K
S
BOOKS
X
D
E S
K
X
D
E S
K
X
D
E S
K
30X66
DESK
X
D
E S
K
X
D
E S
K
24X48 24X48 24X48
X
24X48 24X48
LA
T FILE
LA
T FILE
LA
T FILE
B O
O K
S
LA
T FILE
LA
T FILE
LA
T
FI
LE
WATER
MAIN VALVE
TELECOM ROOM
001A 02-E300
02-E300
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:2
:2
A M
02-E200
BASEMENT FLOOR PLAN -
ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
TBD GJL
16305
1/8" = 1'-0"
BASEMENT FLOOR PLAN - ELECTRICAL
N
100% CD 03/30 05-06-2022
WS1WS2
WS3
WS6
WS5 WS4
OFFICE
STAIR
GROUP
ROOM
GROUP
ROOM
VENDING
GROUP
ROOM
OFFICE
MULTI-
PURPOSE
DIRECTOR
OFFICE
OFFICE
GROUP
ROOM
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
C1W
OFFICE
STORAGE
PIPE CHASE
131A
FEMALE
TOILET
MALE
TOILET
OFFICE
OFFICE
STAIR
HALL
OFFICE
ELEVATOR
LOBBY
OFFICE
OFFICE
FEMALE
OFFICE
PIPE CHASE
132A
GROUP ROOM
OFFICE
105A
PIPE
CHASE
104A
BEDROOM
BEDROOM
101A
4 BED
VEST.
DAYROOM
106A
4 BED
STAIR
CORRIDOR
C1C
WAITING
OFFICE
NURSING
OFFICE
CORRIDOR
C1E
STAFF
HAC
119 STAIR
HALL
PIPE CHASE
116A
3 BED
TOILET
LAUNDRY/
SHOWER
PIPE CHASE
115A
GROUP
ROOM
TOILET
111A
2 BED
111 3 BED
BEDROOM
STOR
OFFICE
MEDROOM
105B
EXAM
W D
BUILDING 2 1ST FLOOR
LAST UPDATED: 4-28-20
15,715 EXISTING G.S.F.
B02IT-1-CR-11
WP
CU-2-1
B02IT-1-CR-7,9
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:2
:3
A M
02-E201
FIRST FLOOR PLAN -
ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
TBD GJL
16305
1/8" = 1'-0"
FIRST FLOOR PLAN - ELECTRICAL
KEYNOTES:
1. PROVIDE ELECTRICAL CONNECTION TO
CONDENSING UNIT, AS REQUIRED.
COORDINATE FINAL LOCATION AND
CONNECTION REQUIREMENTS WITH
MECHANICAL.
N
100% CD 03/30 05-06-2022
SD
TELECOM ROOM
001A
AC-2-1
B02IT-1-CR-1,3,5
2MDP
(20A/3P)
B02IT-1-CR
2ES
ATS-CR
ATS-LS
2EC
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:2
:3
A M
02-E300
ELECTRICAL ENLARGED
PLANS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
TBD GJL
16305
N O R
HT
1/4" = 1'-0"
BASEMENT ENLARGED - 001A -
POWER AND SYSTEM
KEYNOTES:
1. INDOOR UNIT TO BE POWERED BY OUTDOOR
UNIT. COORDINATE EXACT LOCATION WITH
M.C.
2. CONNECT SMOKE DETECTOR TO NEAREST
EXISTING SLC.
3. COORDINATE FINAL LOCATION OF
RECEPTACLE L21-20R WITH TELECOM
CONTRACTOR. PROVIDE 3/4"C-4#12, 1#12 GND
TO PANEL FOR EACH RECEPTACLE.
4. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-
PHASE,4-WIRE RACK MOUNTED UPS FOR EACH
RACK TOWER.
5. PROVIDE APC#AP8861 RPDU RACK PDU 2G
WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,
ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R
OUTLETS. PROVIDE TWO PER RACK, MOUNTED
PER MANUFACTURER'S REQUIREMENTS.
6. VERIFY EXACT CIRCUIT AVAILABILITY IN PANEL
AND REARRANGE BREAKERS TO ALLOW 3
CONSECUTIVE SPACES.
4 5
SHEET NOTES:
1. REFER TO TECHNOLOGY PLANS FOR IT ROOM
LAYOUT AND RACK LAYOUT/DETAILS.
2. REFER TO SHEET 0-GE400 DETAIL FOR LAYOUT
& ONE-LINE OF RACK.
N O R
HT
1/4" = 1'-0"
BASEMENT ENLARGED -
ELECTRICAL - MECH 11
0 4' 8'2' 0 4' 8'2'
NN
100% CD 03/30
05-06-2022
BASEMENT
FIRST FLOOR
B02IT-1-CR
60Y
2EC
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:2
:3
A M
02-E400
ELECTRICAL DIAGRAMS &
SCHEDULE
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
TBD GJL
16305
12" = 1'-0"
PARTIAL POWER RISER
KEYNOTES:
1. REMOVE EXISTING 20A/3P SPARE CIRCUIT
BREAKER AND INSTALL NEW 60A/3P CIRCUIT
BREAKER TO MATCH EXISTING TYPE AND AIC
RATING.
100% CD 03/30
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 19.9 A
TOTAL CONNECTED AMPS: 19.93 A
TOTAL ESTIMATED DEMAND LOAD: 7.18 kVA
Receptacles 0.18 kVA 100.00% 0.18 kVA TOTAL CONNECTED LOAD: 7.18 kVA
Power 7 kVA 100.00% 7 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 23.27 23.27 15.39
Total Load: 2.67 kVA 2.67 kVA 1.85 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --
11 WP GFI REC 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 12 --
-- 9 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 10 --
7 CU-2-1 20 A 2 1 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 6 --
-- 3 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 4 --
1 L21-20R RACK 20 A 3 1.67 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
SCCR: 10 kA
LOCATION: WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 60 A MCB
PANEL B02IT-1-CR
2EC
05-06-2022
FIRST FLOOR
3-EQ3-1
SECOND FLOOR
PENTHOUSE
B03IT-1-EQ
100Y
BASEMENT
3-MDP-1
B03IT-1
100Y
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/2
/2
:5
:5
A
M
03-E400
ELECTRICAL RISER
DIAGRAMS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
TBD GJL
16305
12" = 1'-0"
PARTIAL POWER RISER
KEYNOTES:
1. PROVIDE NEW CIRCUIT BREAKER TO MATCH
EXISTING TYPE AND AIC RATING.
100% CD 03/30
53095
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/2
/2
:5
:5
A
M
03-E500
ELECTRICAL SCHEDULES
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
TBD GJL
16305
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 15.9 A
TOTAL CONNECTED AMPS: 15.88 A
Receptacles 0.72 kVA 100.00% 0.72 kVA TOTAL ESTIMATED DEMAND LOAD: 5.72 kVA
Power 5 kVA 100.00% 5 kVA TOTAL CONNECTED LOAD: 5.72 kVA
Lighting 0 kVA 0.00% 0 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 16.89 15.39 15.39
Total Load: 2.03 kVA 1.85 kVA 1.85 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --
11 WP GFI REC. 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 0 0.18 1 20 A WP GFI 10
-- 7 -- -- -- -- -- -- 1.67 0 1 20 A Lighting 8
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- -- -- -- 6 --
3 L21-20R RACK 20 A 3 1.67 0 -- -- -- -- -- -- 4 --
1 TELECOM ROOM REC. 20 A 1 0.36 0 3 20 A L21-20R 2
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES: PROVIDE INTEGRAL ELECTRIC METER IN PANEL.
SCCR: 10 kA
LOCATION: TELECOM ROOM 205E WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B03IT-2
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 20.4 A
TOTAL CONNECTED AMPS: 20.43 A
Receptacles 0.36 kVA 100.00% 0.36 kVA TOTAL ESTIMATED DEMAND LOAD: 7.36 kVA
Power 7 kVA 100.00% 7 kVA TOTAL CONNECTED LOAD: 7.36 kVA
Lighting 0 kVA 0.00% 0 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 26.50 13.89 23.50
Total Load: 3.03 kVA 1.67 kVA 2.67 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 14 --
11 CU-3-1 20 A 2 1 0 -- -- -- 1 20 A SPARE 12 --
9 Lighting 20 A 1 0 0 -- -- -- 1 20 A SPARE 10 --
7 TELECOM ROOM REC. 20 A 1 0.36 0 1 20 A Lighting 8
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- -- -- -- 6 --
-- 3 -- -- -- -- -- -- 1.67 0 -- -- -- -- -- -- 4 --
1 L21-20R RACK 20 A 3 1.67 0 3 20 A L21-20R 2
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
SCCR: 10 kA
LOCATION: TELECOM ROOM 205E WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B03IT-2-EQ
3-MPD-1
3-EQ3-1
53095
T
LOCKER
STAFF TOILET
CORRIDOR
CIB
IT
INSTRUMENT PREP
OPERATORY
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .